Loading...
FSS2022-0243ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 AMANDA@JDMECHAN ICAL.CO CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 AMANDA@JDMECHAN ICAL.CO OWNER KNICKERBOCKER TRUST 53639 FREMONT WAY LA QUINTA CA 92253 (760)775-6220 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 6/14/2022 6/14/2022 REQUESTED FP-1 PLAN SHEET. CONDITIONS Description: LOT 96 KNICKERBOCKER Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 6/13/2022 ECON Parcel No: 767710009 Site Address: 53639 FREMONT WY LA QUINTA,CA 92253 Approved: 8/16/2022 KHET Subdivision: TR 33076-2 Block: Lot: 96 Issued: 8/17/2022 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/16/2023 LRO Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, April 13, 2023 3:23:01 PM 1 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0243 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 8/31/2022 8/31/2022 APPROVED No leaks DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 3/13/23 WEB14608 196954276 CREDIT 1020141 ECON FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $167.00 $167.00 9/13/22 WEB13031 723795836 CREDIT 1020141 ECON FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $175.00 $175.00 3/3/23 WEB14509 825775897 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $250.00 $250.00 8/17/22 WEB12780 708702012 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 8/17/22 WEB12780 708702012 CREDIT 1020141 ECON Total Paid for FIRE FEES: $1,017.00 $1,017.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 8/17/22 WEB12780 708702012 CREDIT 1020141 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 8/17/22 WEB12780 708702012 CREDIT 1020141 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,033.00 $1,033.00 Printed: Thursday, April 13, 2023 3:23:01 PM 2 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0243 BOND INFORMATION OVERHEAD ROUGH PIPING KHET 8/31/2022 8/31/2022 DISAPPROVE D SEE ATTACHMENTS Insulation protection throughout. FAU coverage in mid attic. As-built changes, require Revised plans and calcs prior to final OVERHEAD ROUGH PIPING LIN 9/13/2022 9/13/2022 APPROVED Reinspection APPROVED OH Rough based on KHetrick's redlined plans. FIRE FINAL**KHET 3/6/2023 3/6/2023 DISAPPROVE D SEE NOTES CANCELLED DUE TO CORRECT PLANS/REVISIONS ARE SUBMITTED AND APPROVED Missing 2 trim in mechanical closets where heads were present. Patch/Paint work around heads still present in some areas - Needs to be complete. FIRE FINAL**LRO 3/16/2023 3/16/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 6/13/2022 6/27/2022 7/18/2022 REVISIONS REQUIRED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 6/13/2022 6/14/2022 6/14/2022 COMPLETE 2ND FIRE (1 WK)KOHL HETRICK 7/21/2022 7/28/2022 8/16/2022 APPROVED SEE ATTACHMENTS 3RD FIRE (1 WK)KOHL HETRICK 2/17/2023 2/24/2023 3/1/2023 REVISIONS REQUIRED SEE ATTACHMENTS 4TH FIRE (1 WK)KOHL HETRICK 3/1/2023 3/8/2023 3/2/2023 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Thursday, April 13, 2023 3:23:01 PM 3 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0243 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/13/2022 Etrakit Contractor 1ST SUBMITTAL FP-3 Knickerbocker Residence.pdf2nd Floor Piping.pdf 1 DOC 6/13/2022 Etrakit Contractor 1ST SUBMITTAL CVWD Scan_0190.pdf 1 DOC 6/13/2022 Etrakit Contractor 1ST SUBMITTAL SENJU 8464 Senju Concealed 4.9.pdf 1 DOC 6/13/2022 Etrakit Contractor 1ST SUBMITTAL HYDRAULICS Document.pdfCalc-1.pdf 1 DOC 6/13/2022 Etrakit Contractor 1ST SUBMITTAL FP-2 Knickerbocker Residence.pdf1st Floor Piping.pdf 1 DOC 6/14/2022 Etrakit Contractor Knickerbocker Residence.pdfSite.pdf 1 DOC 2/17/2023 Etrakit Contractor Knickerbocker Residence.pdf1st Floor Piping knickerbocker.pdf 1 DOC 2/17/2023 Etrakit Contractor Knickerbocker Residence.pdf2nd Floor Piping knickerbocker.pdf 1 DOC 2/17/2023 Etrakit Contractor Knickerbocker Residence.pdfSite knickerbocker.pdf 1 DOC 2/17/2023 Etrakit Contractor 8464 Senju Concealed 4.9 knickerbocker.pdf 1 DOC 2/17/2023 Etrakit Contractor Document.pdfCalc-1 knickerbocker.pdf 1 DOC 2/17/2023 Etrakit Contractor Document.pdfCalc-3 knickerbocker.pdf 1 Printed: Thursday, April 13, 2023 3:23:01 PM 4 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0243 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/17/2023 Etrakit Contractor VK496 K 3.0 Res Concealed knickerbocker.pdf 1 DOC 2/17/2023 Etrakit Contractor Scan_0001 knickerbocker.pdf 1 DOC 7/18/2022 KOHL HETRICK FSS2022-0243 - 1ST REVIEW - FIRE PLAN CORRECTIONS.pdf FSS2022-0243 - 1ST REVIEW - FIRE PLAN CORRECTIONS.pdf 1 DOC 7/21/2022 KOHL HETRICK 2nd Submittal Knickerbocker Residence.pdfSite.pdf Knickerbocker Residence.pdfSite_1.pdf 0 DOC 7/21/2022 KOHL HETRICK 2nd Submittal 8464 Senju Concealed 4.9.pdf 8464 Senju Concealed 4.9_1.pdf 0 DOC 7/21/2022 KOHL HETRICK 2nd Submittal Document.pdfCalc-1.pdf Document.pdfCalc- 1_1.pdf 0 DOC 7/21/2022 KOHL HETRICK 2nd Submittal Document.pdfCalc-3.pdf Document.pdfCalc-3.pdf 0 DOC 7/21/2022 KOHL HETRICK 2nd Submittal Knickerbocker Residence.pdf1st Floor.pdf Knickerbocker Residence.pdf1st Floor.pdf 0 DOC 7/21/2022 KOHL HETRICK 2nd Submittal Knickerbocker Residence.pdf2nd Floor.pdf Knickerbocker Residence.pdf2nd Floor.pdf 0 DOC 7/21/2022 KOHL HETRICK 2nd Submittal Scan_0001.pdf Scan_0001.pdf 0 DOC 7/21/2022 KOHL HETRICK 2nd Submittal VK496 K 3.0 Res Concealed.pdf VK496 K 3.0 Res Concealed.pdf 0 Printed: Thursday, April 13, 2023 3:23:01 PM 5 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0243 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/16/2022 KOHL HETRICK FSS2022-0243 - APPROVED PLANS AND CALCS.pdf FSS2022-0243 - APPROVED PLANS AND CALCS.pdf 1 DOC 8/16/2022 KOHL HETRICK FSS2022-0243 - COA AND JOB CARD.pdf FSS2022-0243 - COA AND JOB CARD.pdf 1 DOC 8/31/2022 KOHL HETRICK FSS2022-0243 - 8-31- 2022 - Insp Notes.pdf FSS2022-0243 - 8-31- 2022 - Insp Notes.pdf 1 DOC 3/1/2023 KOHL HETRICK FSS2022-0243 - REVISED PLANS AND CALCS - CORRECTIONS.pdf FSS2022-0243 - REVISED PLANS AND CALCS - CORRECTIONS.pdf 1 DOC 3/2/2023 KOHL HETRICK Gl4906 Residencial.pdf Gl4906 Residencial.pdf 1 DOC 3/2/2023 KOHL HETRICK GL5606 Res.pdf GL5606 Res.pdf 1 DOC 3/2/2023 KOHL HETRICK FSS2022-0243 - REVISED PLANS AND CALCS - APPROVED.pdf FSS2022-0243 - REVISED PLANS AND CALCS - APPROVED.pdf 1 Printed: Thursday, April 13, 2023 3:23:01 PM 6 of 6 Permit Details City of La Quinta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iverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST03/02/2023 3:36:03 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2022-0243REVISED PLANS AND CALCSKohl HetrickReason: I am approving this documentContact Info: 760-409-5109 307021080308030802680ARCH26802880268026702670PAIR 2680PAIR 2680vintage50100 POCKET50100 POCKET268026802280228032802680267028803080268026802680409036802880Pair 2280Pair 22802880ARCH1"12' -6"1"0' -7"1"6' -9"1"16' -0"1"14' -9"1"7' -7"1"16' -0"1"8' -3"1" 14' -0" 1" 6' -0" 1" 14' -0" 1 1/2" ? 1" 2' -2" 1" 14' -0" 1" 14' -0" 1" 7' -5" 1" 1' -7" 1" 3' -1" 1" 0' -5" 1" 3' -2" 1" 4' -11" 1" 2' -4" 1" 9' -4" 1" 2' -9" 1" 2' -6"1"1' -1"1"1' -1"1" 2' -1" 1" 2' -11"1"6' -0"1"2' -11"1"9' -11"1"10' -11"1"10' -11"1"9' -7"1"8' -2"1" 2' -3"1"7' -0"1" 8' -0" 1" 7' -9"1"11' -8"1"9' -8"1" 2' -1"1"4' -6"1" 2' -5" 1" 0' -11" 1" 2' -2" 1" 13' -1"1"8' -3"1" 4' -7" 1" 13' -1"1"3' -6"1"12' -0"1"2' -5"1"3' -0"1" 5' -1"1"5' -4"1" 8' -6" 1" 3' -1" 1" 2' -5"1"2' -3"1"4' -3"1"3' -7"1" 5' -8"1"1' -0"1" 10' -0" 1" 1' -0" 1" 2' -3"1"5' -11"1"8' -10"1" 1' -5"1"2' -3"1" 12' -2" 1" 2' -3"1"3' -5"1" 10' -0"1"3' -9"1" 6' -7"1"4' -10"1"1' -11"1" 1' -3"1"5' -3"1" 2' -10" 1" 1' -8" 1" 3' -1" 1" 7' -9" 1" 2' -0" 1" 4' -6" GARAGE 9'-0" BEDROOM SUITE 2 10'-0"BATH 10'-0" LAUNDRY 10'-0" STORAGE 10'-0" GYM 10'-0" OWNERS BATH 10'-0" HER W.I.C. 9'-0"HIS W.I.C. 9'-0" OWNERS BEDROOM SLOPE 11'-4" 11'-4"W.C. W.C. COVERED PATIO GREAT ROOM 10'-6" KITCHEN 10'-6" PREP. KIT. 10'-6" W.I.C. 10'-0" BATH 9'-0: BERROOM 4 10'-6" COVEDED OUTDOOR BEDROOM 3 12'-0" HALL 10'-0" COURT YARD 8' - 3"NOTE THIS 1st FLOOR SYSTEM IS DESIGNED SEPERATE FROM THE 2nd FLOOR SYSTEM. UP NODES SHOWN ON 2nd FLOOR DRAWING NOTE: THESE 4 HEADS SHALL BE VIKING 3.0 K FACTOR UP 2' OVERSPACE CORRECTED UP to 2nd UP to 2nd FAU MID ATTIC FAU MID ATTIC 1" RISER UP to 2nd1" x 0' -10"1" 12' -7"1"3' -5"1"9' -1"1"3' -5"1" x 1' -0"1" x 1' -0"1" 3' -2"1"6' -11"1"1' -6"1"3' -6"1"1' -3"1"6' -11"1"2' -5"1" 0' -9" 1" 2' -3" 1" 2' -3"1"5' -7"1"5' -8"1"0' -4"1" x 4' -0"1"6' -0"1" x 4' -0"1" 3' -10" 1" 3' -1"1"1' -2"1" 5' -5" 1" 5' -9"1"1' -2"1" 9' -8"1"1' -1"1" 9' -9"1"7' -1"1" 0' -6"1"5' -7"1"6' -4"1" 8' -8"1"8' -6"1" 1' -6"1"6' -0"1"6' -0"1"1' -3"1"1' -3"1" 15' -9"1"1' -11"1"0' -4"1" x 4' -0"1" x 7' -11"1" 3' -1"1" x 7' -11"1"1' -6"1" 2' -0"1"1' -1"1" 4' -0"1"1' -2"1" 6' -8"1"5' -8"1" x 1' -0"1" 0' -4"1"5' -10"1" x 1' -0"1 1/2"27' -6"1 1/2"4' -6"1"7' -6"1" x 13' -0"1" 3' -4" 1" 0' -9"1"4' -0"1" x 7' -11"1" x 2' -0"1"0' -4"1" 7' -0" 31' - 10" 15' - 11"8' - 11"jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINC1/8" = 1'-0"3/1/2023 11:01:02 AMFP-2 1st Floor Piping Plan 2nd Correction Project Number Knickerbocker 03-01-23 JA JDKNICKERBOCKERTRUSTRESIDENCE53639 Fremont WayLa Quinta, CaMadison Club Lot 96BSprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 79 Globe 1/2 Light Concealed Temperature - 162 Finish - B Quick Response Model - Mirage SIN - Gl4906 K Factor -4.90 Gl4906 4.9 1/2" 155 °F 14 Globe 1/2 Light Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - Gl5606 K Factor - 4.9 Gl5606 4.9 1/2" 200 °F 10 Viking 1/2 Residential Concealed Temperature - 155 Finish - B Fast Response Model - 22773 SIN - VK496 K Factor - 3 VK496 3 1/2" 154 °F : 103 Total No. of Sprinklers: 103 DECK 4 DECK 3 MECH. DECK 1 ATTIC LAUNDRY 2W.I.C 5A DNTV TV REF. DN DNLINEN LINEN FLAT TV Fire Sprinkler Riser Detail 1" CPVC to supply fire sprinkler system TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1" Potter Horn Strobe Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL www.cadmando.co.uk These blocks were brought to you by CADB locksFree.com.For all of your 2D & 3D CA D outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) INSPECTORS TEST Calc-1 Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 78.35 psi 58.19 psi 41 GPM 0 GPM DOM WM 6 1 3 2 Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 Max SqFt 31.1224 GPM 45.4094 Psi 5 GPM 0 GPM BEDROOM SUITE 7 8'-0" BATH 7 8'-0" STORAGE/MECH SLOPE STORAGE/AV ROOM SLOPE TV LOUNGE 9'-6" LOUNGE 9'-6" 8X10 BEAM 8X10 BEAM 8X10 BEAM 8X10 BEAM BEDROOM SUITE 5 BUNK ROOM 9'-0" BATH 5 8'-6" BATH 6 8'-6" BEDROOM SUITE 9'-6" 1 1/2" 43' -3" 1" 9' -7" 1" 4' -5" 1" 3' -6"1" 5' -0" 1" 1' -1" 1" 3' -10"1"7' -4"1" 8' -9" 1" 7' -4" 1" 2' -3" 1" 10' -7"1"3' -11"1"4' -1"1" 4' -7" 1" 3' -11" 1" 12' -0" 1" 8' -3" 1" 1' -6"1"2' -7"1" 9' -8" 1" 3' -2" 1" 5' -0"1"10' -7"1"10' -7"Up 1" x 9' -0"Dn 1" x 9' -0"4' - 1"8' - 6" 1" Supply from 1st Floor 5' - 10"Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-3 R-3 3 Gpm/SqFt 432 Max SqFt 29.1051 GPM 38.2597 Psi 5 GPM 0 GPM Calc-3 NOTE: THESE 6 HEADS SHALL BE VIKING 3.0 K FACTOR NOTE 8' SPACING UP2 DOWN to 1st DOWN to 1st DOWN to 1st 1" 3' -8" 1" 10' -1" 1" 7' -3" 1" 0' -8" 1" 0' -10" 1" 4' -8"1"4' -5"1"1' -0"1" x 22' -0"1" 4' -11" 1" 1' -6" 1" 0' -8"1"8' -8"1" 11' -7" 1" 1' -9"1"11' -8"1" 1' -0"1"3' -7"1" 2' -11"1"3' -7"1"2' -5"1" 9' -7" 1" 1' -0"1"3' -8"1" 5' -9"1"0' -8"1" 0' -8"1" x 8' -11"1"7' -4"1" 3' -3"20' - 1"21' - 1"1 1/2"4' -6"1 1/2"38' -0"Supply Point 7 4 BOR 5 SOR TOR UP1 8 12' - 0" 14 13 10 9 11 12 jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINCAs indicated 3/1/2023 11:02:17 AMFP-3 2nd Floor Piping Plan 2nd Correction Project Number Knickerbocker 03-01-23 JA JDKNICKERBOCKERTRUSTRESIDENCE53639 Fremont WayLa Quinta, Ca. 92253Madison Club Lot 96B1/8" = 1'-0"1 2nd Floor Piping Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 79 Globe 1/2 Light Concealed Temperature - 162 Finish - B Quick Response Model - Mirage SIN - Gl4906 K Factor -4.90 Gl4906 4.9 1/2" 155 °F 14 Globe 1/2 Light Pendent Temperature - 200 Finish - C Special Response Model - Micromatic SIN - Gl5606 K Factor - 4.9 Gl5606 4.9 1/2" 200 °F 10 Viking 1/2 Residential Concealed Temperature - 155 Finish - B Fast Response Model - 22773 SIN - VK496 K Factor - 3 VK496 3 1/2" 154 °F : 103 Total No. of Sprinklers: 103 JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Knickerbocker Residence Drawing : Location : 53639 FREMONT WAY Remote Area : Calc-1 Contract : Data File : Knickerbocker Residence Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Knickerbocker ResidenceDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 78.35 C2 - Residual Pressure: 58.19 C2 - Residual Flow : 41 D1 - Elevation : 9.177 D2 - System Flow : 31.122 D2 - System Pressure : 45.409 Hose ( Demand ) : _______D3 - System Demand : 31.122 Safety Margin : 20.834 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Knickerbocker ResidenceDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Knickerbocker Residence Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 78.35 58.19 41.0 66.243 31.12 45.409 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 18.19 4.9 7.04 13.0 0.05 256 2 19.0 7.03 3 19.0 7.65 4 19.0 9.17 UP2 10.0 25.57 TOR 10.0 33.47 DOM -1.53 40.53 5.0 BOR -3.0 42.63 5 -3.0 45.25 WM -3.0 45.31 7 -3.0 45.38 SOR -3.0 45.41 6 18.19 4.9 7.17 13.12 0.05 256 8 19.0 7.65 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Knickerbocker Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 18.19 4.90 13.00 1 N 7.0 3.970 150 7.040 to 7.000 -0.351 2 19 13.0 1.101 10.970 0.0307 0.337 Vel = 4.38 2 19 0.0 1 R 1.0 12.300 150 7.026 to N 7.0 8.000 0.0 3 19 13.0 1.101 20.300 0.0306 0.622 Vel = 4.38 3 19 -1.23 1 5R 5.0 39.500 150 7.648 to 3O 15.0 20.000 0.0 4 19 11.77 1.101 59.500 0.0255 1.519 Vel = 3.97 4 19 14.35 1 6O 30.0 64.110 150 9.167 to 4R 4.0 48.000 3.898 UP2 10 26.12 1.101 2N 14.0 112.110 0.1115 12.502 Vel = 8.80 UP2 10 0.0 1 2N 14.0 51.890 150 25.567 to O 5.0 19.000 0.0 TOR 10 26.12 1.101 70.890 0.1115 7.905 Vel = 8.80 TOR 10 0.0 1 N 7.0 11.530 150 33.472 to 7.000 4.994 DOM -1.53 26.12 1.101 18.530 0.1115 2.066 Vel = 8.80 DOM -1.53 + 5.00 5.00 1 N 7.0 1.470 150 40.532 to R 1.0 8.000 0.637 BOR -3 31.12 1.101 9.470 0.1542 1.460 Vel = 10.49 BOR -3 0.0 1.5 2N 18.0 86.160 150 42.629 to 18.000 0.0 5 -3 31.12 1.598 104.160 0.0251 2.617 Vel = 4.98 5 -3 0.0 1 0.420 150 45.246 to 0.0 WM -3 31.12 1.101 0.420 0.1548 0.065 Vel = 10.49 WM -3 0.0 1 0.420 150 45.311 to 0.0 7 -3 31.12 1.101 0.420 0.1548 0.065 Vel = 10.49 7 -3 0.0 1.5 1.330 150 45.376 to 0.0 SOR -3 31.12 1.598 1.330 0.0248 0.033 Vel = 4.98 0.0 SOR 31.12 45.409 K Factor = 4.62 6 18.19 4.90 13.12 1 N 7.0 13.660 150 7.171 to R 1.0 13.000 -0.351 8 19 13.12 1.101 O 5.0 26.660 0.0312 0.832 Vel = 4.42 8 19 1.23 1 4R 4.0 32.160 150 7.652 to O 5.0 9.000 0.0 4 19 14.35 1.101 41.160 0.0368 1.515 Vel = 4.84 0.0 4 14.35 9.167 K Factor = 4.74 3 19 1.23 1 R 1.0 7.330 150 7.648 to 1.000 0.0 8 19 1.23 1.101 8.330 0.0005 0.004 Vel = 0.41 0.0 8 1.23 7.652 K Factor = 0.44 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 5 Knickerbocker Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Knickerbocker Residence Drawing : Location : Remote Area : Calc-3 Contract : Data File : Knickerbocker Residence Area Calc-3.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Knickerbocker ResidenceDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 78.35 C2 - Residual Pressure: 58.19 C2 - Residual Flow : 41 D1 - Elevation : 9.177 D2 - System Flow : 29.105 D2 - System Pressure : 38.260 Hose ( Demand ) : _______D3 - System Demand : 29.105 Safety Margin : 29.395 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Knickerbocker ResidenceDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Knickerbocker Residence Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 78.35 58.19 41.0 67.655 29.11 38.26 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 9 18.19 3 7.1 7.99 0.05 144 10 19.0 6.93 11 19.0 7.03 12 19.0 9.15 UP2 10.0 20.29 TOR 10.0 27.1 DOM -1.53 33.88 5.0 BOR -3.0 35.8 5 -3.0 38.12 WM -3.0 38.17 7 -3.0 38.23 SOR -3.0 38.26 13 18.19 3 7.2 8.05 0.05 144 14 18.19 3 7.22 8.06 0.05 144 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Knickerbocker Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 9 18.19 3.00 7.99 1 N 7.0 7.240 150 7.100 to 7.000 -0.351 10 19 7.99 1.101 14.240 0.0125 0.178 Vel = 2.69 10 19 8.06 1 R 1.0 1.310 150 6.927 to 1.000 0.0 11 19 16.05 1.101 2.310 0.0450 0.104 Vel = 5.41 11 19 8.06 1 2O 10.0 12.000 150 7.031 to 10.000 0.0 12 19 24.11 1.101 22.000 0.0961 2.115 Vel = 8.12 12 19 0.0 1 3R 3.0 43.390 150 9.146 to 3O 15.0 32.000 3.898 UP2 10 24.11 1.101 2N 14.0 75.390 0.0961 7.245 Vel = 8.12 UP2 10 0.0 1 2N 14.0 51.890 150 20.289 to O 5.0 19.000 0.0 TOR 10 24.11 1.101 70.890 0.0961 6.814 Vel = 8.12 TOR 10 0.0 1 N 7.0 11.530 150 27.103 to 7.000 4.994 DOM -1.53 24.11 1.101 18.530 0.0961 1.780 Vel = 8.12 DOM -1.53 + 5.00 5.00 1 N 7.0 1.470 150 33.877 to R 1.0 8.000 0.637 BOR -3 29.11 1.101 9.470 0.1362 1.290 Vel = 9.81 BOR -3 0.0 1.5 2N 18.0 86.160 150 35.804 to 18.000 0.0 5 -3 29.11 1.598 104.160 0.0222 2.312 Vel = 4.66 5 -3 0.0 1 0.420 150 38.116 to 0.0 WM -3 29.11 1.101 0.420 0.1357 0.057 Vel = 9.81 WM -3 0.0 1 0.420 150 38.173 to 0.0 7 -3 29.11 1.101 0.420 0.1357 0.057 Vel = 9.81 7 -3 0.0 1.5 1.330 150 38.230 to 0.0 SOR -3 29.11 1.598 1.330 0.0226 0.030 Vel = 4.66 0.0 SOR 29.11 38.260 K Factor = 4.71 13 18.19 3.00 8.05 1 O 5.0 0.810 150 7.204 to 5.000 -0.351 10 19 8.05 1.101 5.810 0.0127 0.074 Vel = 2.71 0.0 10 8.05 6.927 K Factor = 3.06 14 18.19 3.00 8.06 1 N 7.0 6.070 150 7.217 to 7.000 -0.351 11 19 8.06 1.101 13.070 0.0126 0.165 Vel = 2.72 0.0 11 8.06 7.031 K Factor = 3.04 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 5 Form No. F_032218 20.01.03 Rev 20.1 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK496 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 3.0 (43.2 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATASpecifications:Minimum Operating Pressure: Refer to the Approval Chart.Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar).Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*)Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards:Sprinkler Body: Brass UNS-C84400 or QM BrassDeflector: Phosphor Bronze UNS-C51000Deflector Pins: Stainless Steel UNS-S30200Button: Brass UNS-C31600Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400Compression Screw: 18-8 Stainless SteelYoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeCover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc PlatingShipping Cap: PolyethyleneCover Plate Materials:Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800Spring: Beryllium NickelSolder: Eutectic Available Finishes and Temperature Ratings: Finish Brass ENT Suffix A JN Temperature 155 °F (68 °C)200°F (93 °C) Suffix B E Ordering Information: Refer to Tables 1 and 2. Replaces Form No. F_032218 Rev 19.1 (Replaced cover part numbers.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 5 Form No. F_032218 20.01.03 Rev 20.1 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK496 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish (2) add the suffix for the desired Temperature Rating. (3) Order a cover plate (refer to Table 2) Sprinkler Base Part No. Size 1: Finishes 2: Temperature Ratings NPT Inch BSPT mm Description Suffix1 Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix 22773 1/2 --Brass A 155 °F (68 °C)Red 100 °F (38 °C)B ENT 3,4 JN 200 °F (93 °C)Green 150 °F (65 °C)E Example: 22773AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Accessories Sprinkler Wrenches (see Figure 1): A. Heavy Duty Part Number: 14047WB5 B. Head Cabinet Wrench Part Number: 140316 Sprinkler Cabinet: Part number 01731A. Footnotes 1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. UL Listed as corrosion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 5. Requires a 1/2” ratchet which is not available from us. 6. Optional for removal of the protective cap. Ideal for sprinkler cabinets. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 5 Form No. F_032218 20.01.03 Rev 20.1 TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: Using the cover plate base part number, (1) add the suffix for the desired Finish (2) add the suffix for the required Cover Plate Nominal Rating. Cover Plate Base Part Number4 Size Inch (mm)Style 1: Finishes Temperature Rating Matrix1,2 Description Suffix6 Cover Plate Nominal Rating (Required) Sprinkler Nominal Rating Sprinkler Max. Ambient Ceiling Temperature2 Suffix 23190 2-3/4 (70)Round Polished Chrome F 135 °F (57 °C)155 °F (68 °C)100 °F (38 °C)A 23174 3-5/16 (84)Round Brushed Chrome F-/B 165 °F (73 °C)3 200 °F (93 °C)150 °F (65 °C)C 23179 3-5/16 (84)Square Bright Brass B Corrosion Resistant Sprinkler Coating: ENT5 Example: 23190MA/W = 135 °F (57 °C) Temperature Rated 2-3/4” (70 mm) Diameter Round Cover Plate with a Painted White finish. Antique Brass B-/A Brushed Brass B-/B Brushed Copper E-/B Painted White M-/W Painted Ivory M-/I Painted Black M-/B Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current our price list schedule. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 5 Form No. F_032218 20.01.03 Rev 20.1 APPROVAL CHART VK496, 3.0 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D S p r i n k l e r B a s e Part Number 1 SIN Thread Size Nominal K-Factor Maximum Water Working PressureInchesmmU.S.metric 2 22773 VK496 1/2 15 3.0 43.2 175 psi (12 bar) Maximum Coverage Area 5 W X L Ft. X Ft. (m X m) All Temperatures Deflector to Ceiling Installation Type Listings and Approvals3 Minimum Spacing Ft. (m)Flow gpm (Lpm) Pressure PSI (bar) 4 12 X 12 (3.7 X 3.7) 8 (30.3) 7.1 (0.49) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnotes 6 & 7. See Footnotes 3, 4, and 8 8 (2.4) 14 X 14 (4.3 X 4.3) 12 (45.4) 16 (1.1) 16 X 16 (4.9 X 4.9) 15 (56.8) 25 (1.72) Footnotes 1. Part number shown is the base part number. For complete part number, refer to current our price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv- als. Refer also to Design Criteria. 4. Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 6. Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 7. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 6. 8. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 5 Form No. F_032218 20.01.03 Rev 20.1 DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK496 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK496 (K3.0)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 6 of 5 Form No. F_032218 20.01.03 Rev 20.1 Figure 2: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-1/4”(58 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Figure 3: Identification of Custom Paint for Concealed Covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 4: Square Cover Assembly 23179 3-5/16” (84 mm) Replaces Form No. F_032218 Rev 19.1 (Replaced cover part numbers.) FACTORY APPLIE D C USTO M P AI NT COLOR Page:1 of 8 Document No.U085167 Date:Nov/20/2019 SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Page:2 of 8 Document No.U085167 Date:Nov/20/2019 TECHNICAL DATA Approvals: cULus Listed NSF/ANSI/CAN 61, NSF/ANSI 372 Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPM/psi1/2 (70.6 LPM/bar1/2) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Plate 205°F (96°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (72°C): Uncolored 175°F (79°C): White 205°F (96°C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (72°C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1-1 FIGURE 1. Model RC-RES K=4.9 FIGURE 1-1. Marking (Color Code) OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) FIGURE 2. OPERATION PROCESS (The figure is for illustrative purposes only) Page:3 of 8 Document No.U085167 Date:Nov/20/2019 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as few as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C) 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) Intermediate 205°F (96°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) Page:4 of 8 Document No.U085167 Date:Nov/20/2019 All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: ・ The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. ・ A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Intermediate Temperature Rating 205°F (96°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) ― ― 13 (49.2) 7.0 (0.48) 18×18 (5.5×5.5) 18 (5.5) 17 (64.4) 12.0 (0.83) ― ― 17 (64.4) 12.0 (0.83) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) ― ― 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) Page:5 of 8 Document No.U085167 Date:Nov/20/2019 INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft·lbs (9.5 to 19.0 N·m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Remover RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. FIGURE 3. INSTALLATION FIGURE 4. RATCHET & SOCKET Page:6 of 8 Document No.U085167 Date:Nov/20/2019 FIGURE 5. PROTECTIVE CAP REMOVAL FIGURE 6. INSTALLATION (COVER PLATE ASSEMBLY) FIGURE 7. INSTALLATION (CORRECT and INCORRECT) Page:7 of 8 Document No.U085167 Date:Nov/20/2019 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F / 4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under TABLE A “Hydraulic Design Criteria”). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Limited Warranty For details of warranty, refer to Sales Contract. Page:8 of 8 Document No.U085167 Date:Nov/20/2019 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) or 205°F (96°C)) Cover Plate Assembly 2-5/8 inch (φ68mm) or 3-1/4 inch (φ83mm) or 2-5/8 inch square (□68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Copper Wood Grain Custom Color Custom Pattern 2-5/8" Round, 140°F ○ ○ - - - - - - ○ ○ 3-1/4" Round, 140°F ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 2-5/8" Square, 140°F ○ - - - - - - - ○ ○ 2-5/8" Round, 162°F ○ - - - - - - - ○ ○ 3-1/4" Round, 162°F ○ - - - - - - - ○ ○ Tools for Installation of Model RC-RES ・Socket NR-H For use with a 3/8” drive ratchet (not included) ・Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) ・Cap Remover RC NOV 2016 GFS-150a (Formerly A-38) “THE INCH” QUICK RESPONSE AUTOMATIC SPRINKLER MODEL GL5606 ONE INCH A DJUSTABLE FLAT PLATE CONCEALED PENDENTDESCRIPTION AND OPERATION QUICK RESPONSE WHITE FLAT PLATE CONCEALED PENDENT TECHNICAL DATA SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profi le, aesthetically pleasing design. It provides sprinkler operations approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specifi ed when allowed by the applicable standards. This sprinkler offers the additional feature of greatly in- creased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profi le cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2 3/4" diameter ceiling plate color fi nished to match the specifi er's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth fl ow" of the ceiling. Globe's GL5606 Concealed Sprinkler utilizes a 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off" designed cover plate is easily installed and with a nominal 1" of adjustment makes it easier to get a proper fi t at the ceiling. Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burst allowing the defl ector to drop down and distribute water in an approved pattern to extinguish or control the fi re. 3 5/16” diameter plate 2 3/4” diameter plate See reverse side for Approvals and Specifi cations. Temperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze Defl ector - brass Screw - brass Lodgement Wire - stainless steel Bulb seat - copper Spring - nickel alloy Seal - tefl on Drop Pin - stainless steel Bulb - glass with alcohol based solution, 3mm size Cover Plate - brass Upper Escutcheon Assembly - steel NOTE: Globe’s wrench P/N 332765 must be used to install this sprinkler. CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY INTERMEDIATE 135°F/155°F 175°F/200°F 57°C/68°C 79°C/93°C ORANGE/RED YELLOW/GREEN 100°F 150°F 38°C 66°C NOV 2016 GFS-150a (Formerly A-38) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1FINISHES AVAILABLE ON SPECIAL ORDER. 2FOR PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. SPECIFICATIONS 1 7/8" DIA.1 7/8" DIA. 2 3/4" MAX. 1 7/8" MIN. 2 3/4" DIA.1/8" 2 1/4" DIA. MIN. HOLE IN CEILING FLAT COVER PLATE SUPPORT SHELL DEFLECTOR DROP PIN CUP 1" x 1/2" REDUCER 1" x 1/2" REDUCER CUP DEFLECTOR DROP PINSUPPORT SHELL FLAT COVER PLATE 2 1/4" DIA. MIN. HOLE IN CEILING 2 3/4" MAX. 1 7/8" MIN. 1/8"3 5/16" DIA.CEILING CEILING 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. CROSS SECTIONS ORDERING INFORMATION PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231 www.globesprinkler.com 989-846-4583 1-800-248-0278 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specifi c details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). Quantity Model Number Style Orifi ce Thread Size Temperature Finishes desired Quantity - Wrenches - P/N 332765 Quantity - Protective Caps - P/N 332695 1” ADJUSTMENT FLAT PLATE CONCEALED PENDENT SPECIFY “THE INCH” QUICK RESPONSE AUTOMATIC SPRINKLER MODEL GL5606 ONE INCH A DJUSTABLE FLAT PLATE CONCEALED PENDENT APPROVALS NOMINAL “K” FACTOR THREAD SIZE LENGTH FLAT COVER PLATE FINISHES 5.6 (80 metric) 1/2”NPT (15mm) 2 1/2” (6.4cm) Chrome White Painted Other Finishes1,2 STYLE SIN MODEL HAZARD1 135°F (57°C) Flat Cover Plate 155°F (68°C) Flat Cover Plate cULus *FM NYC-DOB MEA 101-92-E**135°F (57°C) Sprinkler 155°F (68°C) Sprinkler **155°F (68°C) Sprinkler 175°F (79°C) Sprinkler 200°F (93°C) Sprinkler Adjustable Concealed Pendent GL5606 LH/OH X X X X X X X X *FM APPROVED AS STANDARD RESPONSE **NO FM APPROVALS OH: ORDINARY HAZARD LH: LIGHT HAZARD FLAT COVER PLATE SIZES WHITE 135°F (57°C) PART # WHITE 155°F (68°C) PART # CHROME 135°F (57°C) PART # CHROME 155°F (68°C) PART # 2 3/4” DIA. 332726 332731 332724 332729 3 5/16” DIA. 332706 332711 332704 332709 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org August 16, 2022 J D Mechanical Fire Inc 82579 Fleming Way #D Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – KNICKERBOCKER – MADISON CLUB LOT 96 FSS2022-0243 / 53639 FREMONT WAY, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53639 FREMONT WAY PERMIT#: FSS2022-0243 DATE ISSUED: 8/16/2022 DESCRIPTION: KNICKERBOCKER – LOT 96 CONTRACTOR: J D MECHANICAL FIRE INC. HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.