Loading...
FSS2022-0259ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 AMANDA@JDMECHAN ICAL.CO CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 (760)775-6220 AMANDA@JDMECHAN ICAL.CO OWNER CBPIC CA OWNER I 601 S FIGUEROA STE 4900 LOS ANGELES CA 90011 (760)775-6220 CONDITIONS Description: BERNETT / FIRE SPRINKLERS / BRES2021-0351 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 7/1/2022 ECON Parcel No: 767690019 Site Address: 81310 AMUNDSON AVE LA QUINTA,CA 92253 Approved: 11/14/2022 RWI Subdivision: TR 33076-2 Block: Lot: 27 Issued: 6/6/2023 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/29/2023 LRO Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, September 27, 2023 9:07:21 AM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0259 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 11/29/2022 11/30/2022 APPROVED OVERHEAD HYRO KHET 11/29/2022 11/30/2022 APPROVED FIRE FINAL**LRO 5/24/2023 5/24/2023 DISAPPROVE D Paint/Patchwork, Fee's apply. FIRE FINAL**LRO 6/7/2023 6/7/2023 NOT READY See Notes Arrived on site and was informed home was not ready, will re-schedule. No Fee's. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 6/6/23 WEB15350 886637039 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $250.00 $250.00 11/21/22 WEB13668 757150487 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 11/21/22 WEB13668 757150487 CREDIT 1020141 ECON Total Paid for FIRE FEES: $675.00 $675.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/21/22 WEB13668 757150487 CREDIT 1020141 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 11/21/22 WEB13668 757150487 CREDIT 1020141 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$691.00 $691.00 Printed: Wednesday, September 27, 2023 9:07:21 AM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0259 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 7/1/2022 Etrakit Contractor 1ST SUBMITTAL FP-2 Bernett Residence.pdf1st Floor Piping.pdf 1 DOC 7/1/2022 Etrakit Contractor 1ST SUBMITTAL FP-3 Bernett Residence.pdf2nd Floor Piping.pdf 1 DOC 7/1/2022 Etrakit Contractor 1ST SUBMITTAL FP-1 Bernett Residence.pdfSite.pdf 1 DOC 7/1/2022 Etrakit Contractor 1ST SUBMITTAL HYDRAULIC CALCS Document.pdfCalc-2.pdf 1 DOC 7/1/2022 Etrakit Contractor 1ST SENJU SPRINKLERS Senju RC-QR 4.9 Pendant.pdf 1 BOND INFORMATION FIRE FINAL**LRO 6/15/2023 6/15/2023 DISAPPROVE D Paint/Patchwork, no fee's. FIRE FINAL**LRO 6/29/2023 6/29/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 7/1/2022 7/18/2022 8/9/2022 REVISIONS REQUIRED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 7/1/2022 7/5/2022 7/1/2022 COMPLETE 2ND FIRE (1 WK)REBECCA WINSCOTT 8/30/2022 9/6/2022 9/25/2022 REVISIONS REQUIRED 3RD FIRE (1 WK)REBECCA WINSCOTT 11/2/2022 11/9/2022 11/14/2022 APPROVED PARENT PROJECTS Printed: Wednesday, September 27, 2023 9:07:21 AM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0259 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/31/2022 Etrakit Contractor Bernett Residence.pdf1st Floo Piping corrections.pdf 1 DOC 8/31/2022 Etrakit Contractor Bernett Residence.pdf2nd Floor Piping corrections.pdf 1 DOC 8/31/2022 Etrakit Contractor Bernett Residence.pdfSite corrections.pdf 1 DOC 8/31/2022 Etrakit Contractor Document.pdfCalc-1 corrections.pdf 1 DOC 8/31/2022 Etrakit Contractor Document.pdfCalc-2 corrections.pdf 1 DOC 8/31/2022 Etrakit Contractor Senju RC-QR 4.9 Pendant corrections.pdf 1 DOC 8/9/2022 KOHL HETRICK FSS2022-0259 - 1ST REVIEW - FIRE PLAN CORRECTIONS.pdf FSS2022-0259 - 1ST REVIEW - FIRE PLAN CORRECTIONS.pdf 1 DOC 11/14/2022 KOHL HETRICK 3RD SUMBITTAL BERNETT Document.pdfCalc-1.pdf BERNETT Document.pdfCalc-1.pdf 1 DOC 11/14/2022 KOHL HETRICK 3RD SUMBITTAL BERNETT Document.pdfCalc-2.pdf BERNETT Document.pdfCalc-2.pdf 1 DOC 11/14/2022 KOHL HETRICK 3RD SUMBITTAL BERNETT Document_2022-08- 31_114843.pdf BERNETT Document_2022-08- 31_114843.pdf 1 DOC 11/14/2022 KOHL HETRICK 3RD SUMBITTAL Bernett Residence.pdfAS Builds.pdf Bernett Residence.pdfAS Builds.pdf 1 Printed: Wednesday, September 27, 2023 9:07:21 AM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0259 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/14/2022 KOHL HETRICK 3RD SUMBITTAL BERNETT Senju RC-QR 4.9 Pendant.pdf BERNETT Senju RC-QR 4.9 Pendant.pdf 1 DOC 9/25/2022 REBECCA WINSCOTT LQ FSS2022-0259 Bernet Residence DENIED.pdf LQ FSS2022-0259 Bernet Residence DENIED.pdf 1 DOC 11/14/2022 REBECCA WINSCOTT LQ FSS2022-0259 Bernett Residence APPROVED.pdf LQ FSS2022-0259 Bernett Residence APPROVED.pdf 1 DOC 11/14/2022 REBECCA WINSCOTT LQ FSS2022-0259 Bernett Residence COA.pdf LQ FSS2022-0259 Bernett Residence COA.pdf 1 Printed: Wednesday, September 27, 2023 9:07:21 AM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0259 Fire Department Notes A. The installation of new fire sprinkler systems or modifications to existing systems shall comply with the following: NFPA 13D 2016 CBC 2019 CFC 2019 Local Municipal Codes Requirements of the AHJ All Manufacture Installation Guidelines Note: When conflict arrises between existing codes and standards, the most stringent shall apply. B. The Fire Department Shall require the following inspections and tests. 1. Overhead installation and hydrostatic test, ( prior to cover ). a. Normal opperating pressure when no FDC is installed. b. 200psi when FDC is required. c. Two hour minimum. 2. Final sprinkler and underground, ( prior to building final ). a. All inspections shall be scheduled by the contractor of record. b. Inspections shall be scheduled 24 hours in advance. GENERAL NOTES 1.General: All materials and devices shall conform to 2016 NFPA 13D standards. Installation shall conform to all applcable State and Local Codes. 2.Scope of Work: Install a new Residential Fire Protection System. 3.Piping: All overhead pipe and fittings shall be CPVC unless otherwise noted. 4.Design: NFPA 13D 2016 Edition and CFC Chapter 80 Standards. 5.System Demand @ Source. Two Sprinklers Flowing (16X16 Spacing): 31 gpm @ ______psi ( AREA ) 6.Water Supply Data: Water is supplied from public water main in street. Static Pressure: Information Source: 7.Sprinkler Head Spacing and Installation Requirements:Sprinklers shall not be located Closer than 8'-0" apart where there is no intervening obstruction. Sprinklers near potential obstruction shall be located per manufactures instructions. 8.Piping Supports: Piping shall be supported and restrained in conformance with local plumbing codes and CPVC manufactures instructions . Eachpipe section that supplies a drop to a sprinkler shall be secured no more than 12" from the drop to prevent laterial and vertical movement. 9.Pipe lenghts are approximate for hydraulic calculation and plan review purposes only. 10.The owner shall furnish sufficant heat in all areas to prevent freezingof pipe. 11.Waterflow Switch and Alarm: By Others a. A dedicated electrical circuit with a circuit breaker lock shall be provided for waterflow horn/strobes. b. An approved audible sprinkler waterflow alarm shall be visible from the street. The device shall be listed for outdoor use. An approved sign shall be placed at or near the device stating, SPRINKLER FIRE ALARM - WHEN ALARM SOUNDS CALL 911 c. An approved audible sprinkler waterflow alarm module shall be conected to the smoke detectors to alert occupants shall be provided. NFPA 13D REFERANCE NOTES 1. NFPA 13D, Section 8.3.2 Sprinklers shall not be required in bathrooms of 55 sq. ft. and less. 2. NFPA 13D, Section 8.3.3 Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions. (1) The area of the space does not exceed 24 sq. ft. (2) The walls and ceilings are surfaced with noncombustible or limited-combustible material as defined in NFPA 220. 3.NFPA 13D Section 8.3.4 Sprinklers shall not be required in garages, open attached porches, carports, and similar structures. Note that CFC 2016 Chapter 80 Referance Standards requires attached garages, attached porches, carports, and similar structures shall be sprinklered if there is occupied living space above. 4. NFPA 13D Section 8.2.5.6 Shadow Areas Shadow areas shall be permitted in the protection area of a sprinkler as long as the cumulative dry areas do not exceed 15 sq. ft. (1.4 sq. m.) per sprinkler. jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINCAs indicated 11/2/2022 9:03:49 AMFP-1 Site Plan As Builds Project Number LOT 27 B 11-02-22 JA JDBERNETT RESIDENCE81310 Amundson AveLa Quinta, Ca.APN: 779-410-018 WH WHFAU FAU FAU WHWHFAU INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL www.cadmando.co.uk These blocks were brought to you by CADB locksFree.com.For all of your 2D & 3D CA D outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: 2 0.05 1 Gpm/SqFt SqFt 31.4376 GPM 41.2101 Psi 5 GPM 0 GPM 4 8 2 WM DOM SOR 1" 2' -10" 1" 14' -0"1"12' -10"1" 12' -9" 1" 6' -10" 1" 7' -5" 1" 6' -7" 1" 11' -4" 1" 11' -4" 1" 11' -4"1"2' -2"1"15' -0"1" 2' -10" 1" 14' -0" 1" 3' -0"1"15' -8"1"13' -5"1" 10' -2"1"2' -9"1"6' -2"1"7' -6"1" 0' -5" 1" 0' -8" 1" 6' -11"1"2' -10"1"4' -10"1" 9' -10"1"5' -6"1" 1' -0" 1" 8' -5" 1" 4' -6"1"4' -0"1"4' -11"1" 0' -7" 1" 12' -0" 1" 1' -4" 1" 6' -10"1"3' -3"1" 12' -0" 1" 10' -2" 1" 1' -9" 1" 3' -6" 1" 3' -3"1"10' -1"1" 8' -1"1"6' -5"1"3' -9"1" 7' -0"1"12' -0"1" 7' -0" 1" 1' -4"1"10' -3"1" 5' -8"1"2' -0"1" 9' -3" 1" 7' -3" 1" 3' -2"1"12' -6"1" 5' -3" 1" 2' -8" 1" 8' -5" 1" 9' -7" 1" 10' -0"1"6' -11"1" 10' -3"1"6' -0"1" 5' -0" 1" 5' -2" 1" 2' -9"1" 5' -0" 1" 5' -0" 1" 0' -7" 1" 9' -10" 1" 0' -8" 1" 5' -11" 1" 0' -4" 1" 2' -10" 1" 14' -0"Up 1" x 3' -11"Up 1" x 12' -1"Up 1" x 2' -0"Up 1" x 2' -0"Up 1" x 9' -0"Dn 1" x 2' -0"Dn 1" x 2' -0"Dn 1" x 2' -0"Dn 1" x 2' -0"Dn 1" x 11' -0"Dn 1" x 2' -0"Dn 1" x 2' -0"BED 3 10'-1" BATH 10'-1"BED 2 10'-1" BATH 2 10'-1" POW 10'-1" GREAT ROOM 21'-0" OFFICE 10'-1" BATH 10'-1" ELV RM ENTRY 11'-7" REC ROOM 11'-7" BAR KITCHEN 21'-0" PAN 10'-1" BED 1 12'-1" 11'-1" BATH 1 10'-1" HIS 10'-1" HERS 10'-1" MECH MUD 10'-1" LNDRY 10'-1"POW MECH GARAGE 10'-1" GUEST LIV 10'-1" ENTRY MECH GUEST BED 10'-1" BATH 10'-1" 1" FIRE RISER NOTIFICATION DEVICE BY OTHERS 1-1/2" PVC UG BY OTHERS 6 OPEN TO ABOVE Supply Point 26 21 22 7 1 29 TOR 23 28 27 25 24 Fire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1-1/2" PVC UG BY OTHERS Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINCAs indicated 11/2/2022 9:03:53 AMFP-2 1st Floor Piping Plan As Builds Project Number LOT 27 B 11-02-22 JA JDBERNETT RESIDENCE81310 Amundson AveLa Quinta, Ca.APN: 779-410-0181/8" = 1'-0"1 Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 76 Senju1/2 Light Concealed Temperature - 162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 10 Senju 1/2 Light Pendent Temperature - 205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 86 Total No. of Sprinklers: 86 FAU FAU FAU FAU Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 71.00 psi 61.80 psi 34 GPM 0 GPM Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-2 R-3 2 0.05 Gpm/SqFt 512 Max SqFt 31.0714 GPM 35.4936 Psi 5 GPM 0 GPM 16 1711 12 WM2SOR2 1" 7' -0" 1" 2' -2" 1" 2' -2" 1" 2' -7"1"7' -3"1" 13' -5" 1" 1' -6"1"5' -9"1" 4' -9"1"5' -3"1" 7' -0" 1" 5' -0" 1" 5' -2"1" 1' -9" 1" 4' -0"1"12' -0"1" 7' -0" 1" 7' -0" 1" 3' -5" 1" 7' -9" 1" 1' -9" 1" 2' -3" 1" 7' -5" 1" 8' -0" 1" 3' -3" 1" 7' -5" 1" 3' -2"1"12' -0"1" 7' -7" 1" 4' -5" 1" 4' -5" 1" 7' -7" 1" 6' -11"Up 1" x 9' -0"Up 1" x 9' -0"Dn 1" x 9' -0"Dn 1" x 22' -7"Dn 1" x 9' -0"CALC-2 1-1/2" WATER METER 1" FIRE RISER INSPECTORS TEST SECOND MASTER BED 5 9'-6" BATH 9'-6" CL 9'-6" BED 4 9'-6" ELV OPEN TO BELOW ATTIC MECH CL 9'-6" BATH 9'-6" PIPING @ 22' 2nd FLOOR CEILING THIS UP TO 2nd FLOOR THIS UP TO 2nd FLOOR 18 15 19 3 520 DOM2 BOR2TOR2 141" x 2' -5"1"2' -9"1"13' -3"1"13' -3"1"13' -3"1"2' -9"1"2' -9"1" 10' -9" 1" 16' -0" 1" 16' -0" 1" 8' -2"1 1/2"30' -2"1 1/2"65' -6"1 1/2"10' -9"1 1/2" 6' -5" jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINC1/8" = 1'-0"11/2/2022 9:03:54 AMFP-3 2nd Floor Piping Plan AS Builds Project Number LOT 27 B 11-02-22 JA JDBERNETT RESIDENCE81310 Amundson AveLa Quinta, Ca.APN: 779-410-0181/8" = 1'-0"1 2nd Floor PipingSprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 76 Senju1/2 Light Concealed Temperature - 162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 10 Senju 1/2 Light Pendent Temperature - 205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 86 Total No. of Sprinklers: 86 Southwest Fire Pros 31401 Reserve Drive Suite 2 Route 111 Thousand Palms, Ca.92276 760-343-2233 Job Name : Bernett Residence Drawing : Location : Remote Area : Contract : Data File : Bernett Residence Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 1 Bernett ResidenceDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 71 C2 - Residual Pressure: 61.8 C2 - Residual Flow : 34 D1 - Elevation : 5.648 D2 - System Flow : 31.438 D2 - System Pressure : 41.210 Hose ( Demand ) : _______D3 - System Demand : 31.438 Safety Margin : 21.831 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 2 Bernett ResidenceDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 3 Bernett Residence Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 71.0 61.8 34.0 63.041 31.44 41.21 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 21 10.04 4.9 7.04 13.0 0.05 256 22 11.0 7.3 4 13.0 12.34 23 11.0 20.07 TOR 13.0 26.67 DOM 0.94 34.18 5.0 24 -3.0 37.61 25 -3.0 41.13 WM -3.0 41.17 6 -3.0 41.2 SOR -3.0 41.21 26 10.04 4.9 7.52 13.44 0.05 256 8 11.0 13.51 27 11.0 16.08 28 13.0 15.41 29 13.0 15.35 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 4 Bernett Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 21 10.04 4.90 13.00 1 N 7.0 14.960 150 7.040 to 7.000 -0.416 22 11 13.0 1.101 21.960 0.0307 0.674 Vel = 4.38 22 11 13.44 1 2N 14.0 34.840 150 7.298 to 3R 3.0 17.000 -0.866 4 13 26.44 1.101 51.840 0.1140 5.910 Vel = 8.91 4 13 -10.73 1 4R 4.0 108.600 150 12.342 to 5N 35.0 49.000 0.866 23 11 15.71 1.101 2O 10.0 157.600 0.0436 6.864 Vel = 5.29 23 11 10.73 1 4O 20.0 29.500 150 20.072 to 2R 2.0 36.000 -0.866 TOR 13 26.44 1.101 2N 14.0 65.500 0.1140 7.468 Vel = 8.91 TOR 13 0.0 1 N 7.0 12.060 150 26.674 to R 1.0 8.000 5.223 DOM 0.94 26.44 1.101 20.060 0.1140 2.287 Vel = 8.91 DOM 0.94 + 5.00 5.00 1 N 7.0 3.940 150 34.184 to 7.000 1.706 24 -3 31.44 1.101 10.940 0.1571 1.719 Vel = 10.59 24 -3 0.0 1.5 3N 27.0 110.500 150 37.609 to 27.000 0.0 25 -3 31.44 1.598 137.500 0.0256 3.520 Vel = 5.03 25 -3 0.0 1 0.230 150 41.129 to 0.0 WM -3 31.44 1.101 0.230 0.1565 0.036 Vel = 10.59 WM -3 0.0 1 0.230 150 41.165 to 0.0 6 -3 31.44 1.101 0.230 0.1565 0.036 Vel = 10.59 6 -3 0.0 2 1.050 150 41.201 to 0.0 SOR -3 31.44 2.003 1.050 0.0086 0.009 Vel = 3.20 0.0 SOR 31.44 41.210 K Factor = 4.90 26 10.04 4.90 13.44 1 O 5.0 0.960 150 7.519 to 5.000 -0.416 22 11 13.44 1.101 5.960 0.0327 0.195 Vel = 4.53 0.0 22 13.44 7.298 K Factor = 4.98 4 13 10.72 1 N 7.0 2.000 150 12.342 to O 5.0 12.000 0.866 8 11 10.72 1.101 14.000 0.0215 0.301 Vel = 3.61 8 11 0.0 1 8R 8.0 92.490 150 13.509 to 2N 14.0 27.000 0.0 27 11 10.72 1.101 O 5.0 119.490 0.0215 2.567 Vel = 3.61 27 11 -5.74 1 3O 15.0 16.550 150 16.076 to N 7.0 22.000 -0.866 28 13 4.98 1.101 38.550 0.0052 0.200 Vel = 1.68 28 13 5.74 1 5R 5.0 114.700 150 15.410 to 6N 42.0 62.000 0.866 23 11 10.72 1.101 3O 15.0 176.700 0.0215 3.796 Vel = 3.61 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 5 Bernett Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 23 10.72 20.072 K Factor = 2.39 27 11 5.75 1 R 1.0 7.750 150 16.076 to N 7.0 13.000 -0.866 29 13 5.75 1.101 O 5.0 20.750 0.0067 0.140 Vel = 1.94 29 13 0.0 1 8.800 150 15.350 to 0.0 28 13 5.75 1.101 8.800 0.0068 0.060 Vel = 1.94 0.0 28 5.75 15.410 K Factor = 1.46 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros 31401 Reserve Drive Suite 2 Route 111 Thousand Palms, Ca.92276 760-343-2233 Job Name : Bernett Residence Drawing : Location : LOt 27B 81310 Amundson Ave Remote Area : Calc-2 Contract : Data File : Bernett Residence Area Calc-2.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 1 Bernett ResidenceDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 71 C2 - Residual Pressure: 61.8 C2 - Residual Flow : 34 D1 - Elevation : 10.477 D2 - System Flow : 31.071 D2 - System Pressure : 35.494 Hose ( Demand ) : _______D3 - System Demand : 31.071 Safety Margin : 27.718 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 2 Bernett ResidenceDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 3 Bernett Residence Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR2 71.0 61.8 34.0 63.212 31.07 35.494 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 3 21.19 4.9 7.04 13.0 0.05 256 5 22.0 7.49 13 13.0 13.74 17 13.0 15.17 11 22.0 12.38 10 22.0 15.18 18 22.0 15.78 TOR2 22.0 16.2 DOM2 -0.61 29.28 5.0 BOR2 -3.0 31.91 14 -3.0 35.42 WM2 -3.0 35.45 15 -3.0 35.49 SOR2 -3.0 35.49 19 21.19 4.9 7.12 13.07 0.05 256 20 22.0 7.57 12 13.0 14.66 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 4 Bernett Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 3 21.19 4.90 13.00 1 N 7.0 14.060 150 7.040 to O 5.0 12.000 -0.351 5 22 13.0 1.101 26.060 0.0307 0.799 Vel = 4.38 5 22 -4.81 1 R 1.0 132.780 150 7.488 to 6N 42.0 48.000 3.898 13 13 8.19 1.101 O 5.0 180.780 0.0130 2.359 Vel = 2.76 13 13 0.0 1 2N 14.0 94.130 150 13.745 to R 1.0 15.000 0.0 17 13 8.19 1.101 109.130 0.0130 1.423 Vel = 2.76 17 13 8.38 1 N 7.0 11.180 150 15.168 to O 5.0 12.000 -3.898 11 22 16.57 1.101 23.180 0.0480 1.113 Vel = 5.58 11 22 9.50 1 2O 10.0 15.170 150 12.383 to 10.000 0.0 10 22 26.07 1.101 25.170 0.1111 2.797 Vel = 8.79 10 22 0.0 1 R 1.0 4.410 150 15.180 to 1.000 0.0 18 22 26.07 1.101 5.410 0.1111 0.601 Vel = 8.79 18 22 0.0 1 3.770 150 15.781 to 0.0 TOR2 22 26.07 1.101 3.770 0.1111 0.419 Vel = 8.79 TOR2 22 0.0 1 N 7.0 22.610 150 16.200 to 7.000 9.792 DOM2 -0.61 26.07 1.101 29.610 0.1111 3.291 Vel = 8.79 DOM2 -0.61 + 5.00 5.00 1 N 7.0 2.390 150 29.283 to R 1.0 8.000 1.035 BOR2 -3 31.07 1.101 10.390 0.1537 1.597 Vel = 10.47 BOR2 -3 0.0 1.5 3N 27.0 112.830 150 31.915 to 27.000 0.0 14 -3 31.07 1.598 139.830 0.0251 3.503 Vel = 4.97 14 -3 0.0 1 0.230 150 35.418 to 0.0 WM2 -3 31.07 1.101 0.230 0.1522 0.035 Vel = 10.47 WM2 -3 0.0 1 0.230 150 35.453 to 0.0 15 -3 31.07 1.101 0.230 0.1522 0.035 Vel = 10.47 15 -3 0.0 2 0.630 150 35.488 to 0.0 SOR2 -3 31.07 2.003 0.630 0.0095 0.006 Vel = 3.16 0.0 SOR2 31.07 35.494 K Factor = 5.22 19 21.19 4.90 13.07 1 N 7.0 14.060 150 7.115 to O 5.0 12.000 -0.351 20 22 13.07 1.101 26.060 0.0310 0.807 Vel = 4.40 20 22 4.81 1 2N 14.0 42.740 150 7.571 to R 1.0 15.000 3.898 12 13 17.88 1.101 57.740 0.0553 3.194 Vel = 6.03 12 13 -8.37 1 2N 14.0 61.160 150 14.663 to 3O 15.0 33.000 -3.898 11 22 9.51 1.101 4R 4.0 94.160 0.0172 1.618 Vel = 3.20 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 5 Bernett Residence Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 11 9.51 12.383 K Factor = 2.70 5 22 4.81 1 R 1.0 16.000 150 7.488 to 1.000 0.0 20 22 4.81 1.101 17.000 0.0049 0.083 Vel = 1.62 0.0 20 4.81 7.571 K Factor = 1.75 12 13 8.38 1 N 7.0 30.170 150 14.663 to 7.000 0.0 17 13 8.38 1.101 37.170 0.0136 0.505 Vel = 2.82 0.0 17 8.38 15.168 K Factor = 2.15 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 GENERAL DESCRIPTION The Model RC-QR Commercial Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and quick responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-QR should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. They are to be installed per NFPA 13 guidelines. The Model RC-QR has a 5.6 (80.6 LPM/bar1/2) K-factor. For extended installation flexibility, the Model RC-QR provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-QR allows for an increased chance of occupants to escape or evacuate in case of a fire. However, fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. Approvals: Sprinkler Identification Number (SIN): Maximum Working Pressure: Discharge Coefficient (Nominal K-Factor): Temperature Rating: Vertical Adjustment: Cover Plate Finishes: Standard Finishes- Custom Finishes- Please see chart on page 7 for more detail. Physical Characteristics: In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) DESIGN CRITERIA The Model RC-QR sprinklers are listed by UL and C-UL as quick response / standard coverage for use in accordance with NFPA. Also the Model RC-QR is FM Approved as a Standard Response for No-Corrosive Atmospheres. The herein stated rules for use and installation of the Model RC-QR are provided by the manufacturer and must be strictly implemented for safe and full results. Locations of sprinklers must follow the obstruction rules of NFPA 13. The Model RC-QR must only be utilized in sprinkler systems per NFPA 13 guidelines. For proper operational sensitivity, the Model RC-QR must be installed beneath a solid ceiling having a smooth or textured surface. Refer to NFPA 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-QR, due to the exposure of a heat source other than an actual fire. Model RC-QR sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. The Model RC-QR must be installed in accordance with the following instructions: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet & Socket NR-H Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Use the Cap Remover RC Tool to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. The following instructions must be implemented for the maintenance and service of the Model RC-QR. When placing an order, please contact a local distributor with the following information (Model Name and Finish). Model: RC-QR (SS9561, Quick Response, Standard Coverage, Flat Concealed Sprinkler, Pendent, K5.6, Temperature: 162°F(72°C)) cULus Listed 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (68mm), Order Separately from Sprinkler FM Approved 2-5/8 inch (68mm) or 3-1/4 inch (83mm) , Order Separately from Sprinkler Please refer to the chart below for available sizes, and finishes. Standard Finishes Custom Finishes 2-5/8" Round, 140°F - - - - 3-1/4" Round, 140°F 2-5/8" Square, 140°F 1 - - - - - - 1: cULus listed only Socket NR-H For use with a 3/8” drive ratchet (not included) Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) Cap Remover RC OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 14, 2022 JD Mechanical Re: Residential Fire Sprinkler Plan Review – Bernett Residence FSS2022-0259 (81310 Amundson Ave) The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Rebecca Winscott - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 81310 Amundson Ave PERMIT#: FSS2022-0259 DATE ISSUED: 11/14/22 DESCRIPTION: Bernett Residence CONTRACTOR: JD Mechanical HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.