FSS2022-0295ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT INNOVATIVE FIRE PROTECTION 8779 COTTONWOOD AVE # 101 SANTEE CA 92071 (619)593-8200 DERIK@IFPINC.NET CONTRACTOR INNOVATIVE FIRE PROTECTION 8779 COTTONWOOD AVE # 101 SANTEE CA 92071 (619)593-8200 DERIK@IFPINC.NET OWNER JOE CAFFERY 73-241 HWY 111 STE: 1C PALM DESERT CA 92260 (619)593-8200 CONDITIONS Description: CAFFERY / FIRE SPRINKLER / BRES2021-0887 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 8/19/2022 ECON Parcel No: 777140010 Site Address: 80860 VIA PORTOFINO LA QUINTA,CA 92253 Approved: 9/15/2022 RWI Subdivision: TR 29894-2 Block: Lot: 126 Issued: 7/18/2023 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/26/2023 LRO Valuation: $5,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, September 27, 2023 9:53:17 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0295 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 10/26/2022 10/26/2022 APPROVED OVERHEAD ROUGH PIPING LIN 10/26/2022 10/26/2022 APPROVED SEE ATTACHMENTS Revised plans and calcs required prior to final FIRE FINAL**LRO 7/26/2023 7/26/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $175.00 $175.00 7/18/23 WEB15727 112191290 8 CREDIT 711148 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 9/29/22 WEB13195 732658031 CREDIT 711148 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 9/29/22 WEB13195 732658031 CREDIT 711148 ECON Total Paid for FIRE FEES: $592.00 $592.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 9/29/22 WEB13195 732658031 CREDIT 711148 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 9/29/22 WEB13195 732658031 CREDIT 711148 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$608.00 $608.00 Printed: Wednesday, September 27, 2023 9:53:17 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0295 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/19/2022 Etrakit Contractor DATA SHEETS C8222 CAFFERY_DATA SHEETS.pdf 1 DOC 8/19/2022 Etrakit Contractor 1ST SUBMITTAL - FIRE SPRINKLER PLAN C8222 CAFFERY_FIRE SPRINKLER PLAN.pdf 1 DOC 8/19/2022 Etrakit Contractor 1ST SUBMITTAL - HYDRAULIC CALCULATIONS C8222 CAFFERY_CALCS.pdf 1 DOC 7/10/2023 JOSE DELGADO C8222 CAFFERY_Construction Change Letter.pdf C8222 CAFFERY_Construction Change Letter.pdf 0 DOC 7/10/2023 JOSE DELGADO C8222 CAFFERY_REVISED FIRE SPRINKLER PLAN.pdf C8222 CAFFERY_REVISED FIRE SPRINKLER PLAN.pdf 0 DOC 7/10/2023 JOSE DELGADO C8222 CAFFERY_REVISED CALCULATIONS.pdf C8222 CAFFERY_REVISED CALCULATIONS.pdf 0 DOC 10/26/2022 KOHL HETRICK FSS2022-0295 - 10-26- 2022 - Insp Notes.pdf FSS2022-0295 - 10-26- 2022 - Insp Notes.pdf 1 DOC 7/17/2023 KOHL HETRICK FSS2022-0295 - REVISED PLANS AND CALCS - APPROVED.pdf FSS2022-0295 - REVISED PLANS AND CALCS - APPROVED.pdf 1 BOND INFORMATION 1ST FIRE - ETRAKIT (2 WK) REBECCA WINSCOTT 8/19/2022 9/2/2022 9/15/2022 APPROVED 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 8/19/2022 8/22/2022 8/19/2022 COMPLETE EMAILED CONTRACTOR BUSINESS LICENSE RENEWAL APPLICATION TO THE APPLICANT. 2ND FIRE (1 WK)KOHL HETRICK 7/10/2023 7/17/2023 7/17/2023 APPROVED Revised Plans Printed: Wednesday, September 27, 2023 9:53:17 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0295 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/15/2022 REBECCA WINSCOTT LQ FSS2022-0295 Caffrey Residence (APPROVED).pdf LQ FSS2022-0295 Caffrey Residence (APPROVED).pdf 1 DOC 9/15/2022 REBECCA WINSCOTT LQ FSS2022-0295 Caffrey Residence (COA).pdf LQ FSS2022-0295 Caffrey Residence (COA).pdf 1 Printed: Wednesday, September 27, 2023 9:53:17 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0295 BASE OF THE RISER1. GPM DISCHARGE2. RESIDUAL PRESSURE AT THE2. SPRINKLER PROTECTION AREASystem Demandserved by this riser:Basis of Designin calculated area:No. of SprinklersNo. of Sprinklers1. DENSITYLocationAT SOURCE3. PRESSURE REQUIREDHYDRAULIC-SYSTEMThis building is protectedby a Hydraulically DesignedAutomatic Sprinkler System.GPM/ft²AT SOURCE4. PRESSURE AVAILABLEAT SOURCE5. SURPLUS PRESSUREBEDROOM 221 gpm142.6 psi53.9 psi94.5 psi40.6 psi0.05BASE OF THE RISER1. GPM DISCHARGE2. RESIDUAL PRESSURE AT THE2. SPRINKLER PROTECTION AREASystem Demandserved by this riser:Basis of Designin calculated area:No. of SprinklersNo. of Sprinklers1. DENSITYLocationAT SOURCE3. PRESSURE REQUIREDHYDRAULIC-SYSTEMThis building is protectedby a Hydraulically DesignedAutomatic Sprinkler System.GPM/ft²AT SOURCE4. PRESSURE AVAILABLEAT SOURCE5. SURPLUS PRESSURECASITA26.6 gpm244 psi57.8 psi94.5 psi36.7 psi0.05MASTER BEDROOMGREAT ROOMKITCHEN1" RISER ASSEMBLY(SEE DETAIL #4)11" WATER METER1" COPPER "K"± 20'-0"112" PVC±68'-0"FIRE ALARM BELL23ACITY WATER MAIN 125ft²221ft²3EXTERIOR211ft²211ft²28ft²210ft²127ft²142ft²152ft²221ft²3EXTERIOR3EXTERIORINSPECTOR'S TEST VAKEYLESS HOSE BIB5'-0" AFF LABELED(FIELD VERIFYBEST LOCATION)201202ELECTRIC FIREALARM BELL1" BRASS RESIRISERW/ SPARE HEAD BOXG51,23' - 0 "2'-0"1'-0"3' - 0 "2'-0"2'-0"3' - 0 "1953EXTERIOR4' - 0 "0020010423BBORR008007MAIN DRAIN VALVEUSAGAUGECHECK VALVERISER MANIFOLD W/:(2) FLOW SWITCH(1) DRAIN AND TEST (3) PRESSURE GAUGE(4) SIGNS ON BODYSCUCLTESTANDDRAINFLOW1" ADAPTER SLIP X FIPTUL LISTED CPVC TO SYSTEM5 gpm to DOMESTIC ACCESS PANEL1" COPPER MIPI.F.P.POINT OF CONNECTION(E) MAIN 8.0ASSUMEDCORP. STOP1" COPPER "K"(20'-0" WORST CASE)1" CPVC112" PVC(68'-0" WORST CASE)PROVIDE A PERMANENT WARNING SIGN with MINIMUM 14" LETTERS ADJACENT to MAINSHUT-OFF STATING THE FOLLOWING:"WARNING: THE WATER SYSTEM TO THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRECERTAIN FLOWS AND PRESSURES TO FIGHT A FIRE. DEVICES THAT RESTRICT FLOW ORDECREASE the PRESSURE or AUTOMATICALLY SHUT OFF the WATER to the FIRE SYSTEM,SUCH as WATER SOFTENERS, FILTRATION SYSTEMS and AUTOMATIC SHUT-OFF VALVES, SHALLNOT be ADDED WITHOUT a REVIEW of the FIRE PROTECTION SPECIALIST.DO NOT REMOVE THIS SIGN. "☺SPARE HEAD BOX w/ 1 OF EACH TYPEAND INSTALLERS NAME & PHONE NUMBERIFP2-02-I13ABORR-IR-0DOMESTIC SHUT-OFF VALVE3BG51" WATER METER(FIRE + DOMESTIC)1" COPPER "L"(4'-0" WORST CASE)MAIN CONTROL VALVESYSTEM SENSORFLOW STITCHw/ RETARD10" ALARM BELLw/ CALL 911 SIGN(WIRING BY OTHERS)CAFFERY RESIDENCE HIDEAWAY 126 LA QUINTA CA 92253 80860 VIA PORTOFINO License #C16-711148 #DATEBYREVISIONSAUTHORITY HAVING JURISDICTION1RIVERSIDE COUNTY FIRE AUTHORITYPHONE:8779 COTTONWOOD AVE. SUITE #101 SANTEE, CA. 92071 PHONE: (619) 593-8200 FAX: (619) 593-9133JOB NUMBERDESIGNERDATEC8222DAVIN9/9/2021DESCRIPTIONSHEETCONTRACTOR: ADDRESS: PHONE: CAFFERY CAPITAL DEVELOPMENT LLC 73-241 HWY 111 STE. 1C 760-275-8800 (JOE) PALM DESERT CA. 92260 ARCHITECT: ADDRESS: PHONE: - - - -951-955-5282HYDRAULIC CALCULATIONS16'X16'4020'X20'403'-0" MINIMUM MEASURED FROMTHE CENTER OF THE FIXTURE TOTHE CENTER OF THE FIRE SPRINKLERTYPICAL INSTALLATION FORCEILING FAN OBSTRUCTIONNFPA 13D 8.2.5.1.1FIRE SPRINKLER PIPEFIRE SPRINKLER HANGERFIRE SPRINKLER HEADMINIMUM DISTANCE FROM FIRE SPRINKLERHEAD TO OBSTRUCTION ALONG WALLNFPA 13D 8.2.5.3.3(a)FIRE SPRINKLER PIPEFIRE SPRINKLER HANGERFIRE SPRINKLER HEADA (D - 8 in.) + B>_WHERE: D 30 in.>_WALLOBSTRUCTIONFP-1SITE PLANGENERAL NOTES1.WET PIPE SYSTEM DESIGNED PER 2016 NFPA 13D and/or 2019 CRC 313.3 and THE SPECIFIC REQUIREMENTS OF THE RIVERSIDE COUNTY FIRE AUTHORITY.2.ALL MATERIALS INSTALLED SHALL BE U.L. AND/OR F.M. LISTED "APPROVED" FOR FIRE PROTECTION USE,WHERE APPLICABLE.3.SYSTEM PIPING SHALL BE SUPPORTED PER REQUIREMENTS OF 2016 NFPA 13D and/or 2019 CRC 313.3 andMANUFACTURER'S SPECIFICATIONS, AS APPLICABLE.4.SYSTEM SHALL BE HYDROSTATICALLY TESTED FOR TWO HOURS AT 200 psi AND BE VISUALLYINSPECTED BY THE SERVING FIRE DEPARTMENT BEFORE ANY PIPING IS CONCEALED BY OTHER TRADES.5.ARRANGEMENT OF WATER SUPPLY SHALL BE PER 2016 NFPA 13D and/or 2019 CRC 313.3 and AS APPROVEDBY THE RIVERSIDE COUNTY FIRE AUTHORITY, MAIN SYSTEM CONTROL VALVE SHALL BE LOCATED AHEADOF LATERAL CONNECTION TO DOMESTIC WATER SERVICE ON COMBINED SYSTEMS6.SPACING OF SPRINKLERS SHALL BE:16'-0"- MAXIMUM FROM CENTER OF MULTIPLE HEADS IN A ROOM.8'-0"- MAXIMUM FROM FACE OF WALL IN ANY DIRECTION.8'-0"- MINIMUM FROM CENTER TO CENTER OF MULTIPLE RESIDENTIAL HEADS IN A ROOM.7.MINIMUM FLOW PER SPRINKLER SHALL BE CALCULATED AS FOLLOWS:TWO HEADS FLOWING:13.0 GPM PER SPRINKLER AT 16'x16' SPACING.ONE HEAD FLOWING:21.0 GPM PER SPRINKLER AT 20'x20' SPACING.8.PIPE SIZES AND TYPES SHALL BE AS FOLLOWS:RISER: - 1" RESI RISERSUPPLY MAINS:- 1 & 34" CPVCSPRINKLER LATERALS:- 34" CPVC9.SYMBOLS USED ON THIS PLAN:10SPRINKLERS ARE NOT TO BE INSTALLED IN THE FOLLOWING AREAS:A.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55ft² AND LESS. NFPA13D 8.3.2.B.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WITHINDWELLING UNITS THAT MEET ALL OF THE FOLLOWING CONDITIONS.(1)THE AREA OF THE SPACE DOES NOT EXCEED 24ft².(2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220. NFPA13D 8.3.3.C.SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. NFPA 13D 8.3.4.D.SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE, PENTHOUSE EQUIPMENTROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT, FLOOR / CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES. NFPA 8.3.5.E.SPRINKLERS SHALL NOT BE REQUIRED IN COVERED, UNHEATED PROJECTIONS OF THE BUILDING ATENTRANCES / EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. NFPA 13D 8.3.6.11.WHERE WATERFLOW ALARMS ARE PROVIDED, TEST CONNECTIONS SHALL BE INSTALLED AT LOCATIONSTHAT ALLOW FLOW TESTING OF WATER SUPPLIES, CONNECTIONS, AND ALARM MECHANISMS.12.ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE SEALED IN AN APPROVED MANNERTO MAINTAIN THE INTEGRITY OF THE ASSEMBLY.13.DRILLING AND NOTCHING OF STRUCTURAL MEMBERS SHALL BE PERFORMED IN STRICT ACCORDANCEWITH THE CALIFORNIA BUILDING CODE and MANUFACTURE GUIDELINES.14.WATER CALCULATIONSWATER AUTHORITY:COCHELLA VALLEY MUNICIPAL WATER DISTRICTNAME & NUMBER TO CONTACT:RUBEN MONTIEL (760-398-2651)STATIC PRESSURE:105-10%= 94.5psiMETER SIZE:1"RESIDUAL PRESSURE:89.5psiMETER LOSS:-4psi PER TWO HEAD CALCULATIONFLOW:500gpmUNDERGROUND SIZE:112" PVC TO SATISFY DEMANDDENOTES HYDRAULIC REFERENCENODE.DENOTES HYDRAULIC PIPE SEGMENT.DENOTES RESIDENTIAL FIRE SPRINKLERSSENJU RC RES 49SENJU RC RES 49RELIABLE F1 RES 49SS8464SS8464R3516MAKE and MODELSYMBSI#16'x16'16'x16'4.94.94.9K-FACSIZETEMPTYPEFINISHCANOPYQTYSPACING12"12"12"162°205°175°RESIDENTIALRESIDENTIALRESIDENTIALWHITEWHITEWHITECONCEALEDCONCEALEDSEMI-RECESS3541TOTAL HEAD COUNT - 4016'x16'20'x20'LEGAL DESCRIPTIONOWNER:ADDRESS:A.P.N:# OF STORIES:BUILDING TYPE:OCCUPANCY TYPE:TOTAL LIVING:TOTAL GARAGE:JOE CAFFERY73-241 HWY 111 SUITE 1C PALM DESERT CA. 92260777-140-0101VBR-3, U4,453ft²568ft²VICINITY MAPSCOPE: INSTALL A NEW FIRE SPRINKLER SYSTEM per NFPA 13Dfor a NEW SINGLE FAMILY DWELLING.1SECTION PLANRISER DETAILSPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55ft²AND LESS. per NFPA 13D 8.3.2FIRE SPRINKLER OMISSION LEGENDPER NFPA 13D1SPRINKLERS SHALL NOT BE REQUIRED IN COVERED, UNHEATEDPROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONGAS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS.per NFPA 13D 8.3.6SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS, AND PANTRIES WITHIN DWELLING UNITS THATMEET ALL OF THE FOLLOWING CONDITIONS.(1)THE AREA OF THE SPACE DOES NOT EXCEED 24ft².(2)THE WALLS AND CEILINGS ARE SURFACED WITHNONCOMBUSTIBLE OR LIMITED COMBUSTIBLEMATERIALS AS DEFINED BY NFPA 220.per NFPA13D 8.3.32342"KITCHEN RANGEFRONT of WALL-MOUNTED HOT AIRDIFFUSERSUNINSULATED HEAT DUCTSSIDE of CEILING or WALL-MOUNTEDHOT AIR DIFFUSERSUNISULATED HOT WATER PIPESHOT AIR FLUES60"36"MINIMUM DISTANCE FROM EDGEOF SOURCE TO ORDINARY-TEMPERATURE SPRINKLERHEAT SOURCECOAL or WOOD-BURNING STOVEWALL OVENFRONT of RECESSED FIREPLACE18"18"18"24"12"18"SIDE of OPEN or RECESSED FIREPLACEHOT WATER HEATER or FURNACELIGHT FIXTURE: 0 W - 250 WLIGHT FIXTURE: 250 W - 499 W36"6"6"12"12"36"12"MINIMUM DISTANCE FROM EDGEOF SOURCE TO INTERMEDIATE-TEMPERATURE SPRINKLER9"9"9"12"6"9"18"3"3"6"RATINGS of SPRINKLERS inSPECIFIED RESIDENTIAL AREASper 2016 NFPA 13D, Table 7.5.6.3HANG AND/OR SUPPORT CPVC PLASTIC PIPES TO WOODFRAMING WITH AFCON FASTENERS FOR WOOD, OBSERVINGSPECIFICATIONS AND SPACING RULES AS DEFINED IN CHARTSHOWN BELOWHARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLECPVC NOMINALPIPE SIZE (IN.)MAX. HANGERSPACING (FT.)FASTENERHEX HEAD SIZE34"Ø5'-6"516"1"Ø6'-0"516"114"Ø 6'-6"516"112"Ø7'-0"516"2"Ø8'-0"516"U.L. LISTED HANGERS FOR CPVC PLASTIC PIPEMEETS OR EXCEEDS THE REQUIREMENTS OFNFPA 13, 13R, & 13D SYSTEMS.2610 COMMERCE WAY, VISTA, CA, 92081 PHONE:800-854-1015 FAX: 800-924-5922HARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLEHARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLEHARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLEHANGER SPACING for CPVCNo. 51O 2-HOLE FLAT STRAP HANGERNo. 551 SIDE-MOUNT HANGER No. 514 STAND-OFF NO-BLOCK HANGERNo. 515 DOUBLE OFFSET HANGERTYPICAL HANGERS for CPVCNominal PipeSize (ANSI)MaximumSupport Spacing34"5'-6"1"6'-0"114"6'-6"112"7'-0"2"8'-0"212"9'-0"3"10'-0"HANGER SPECIFICATIONS"S" MAXANYDISTANCECPVC NOMINALPIPE SIZE (IN.)"R"(LESS THAN 100 psi)TABLE "R" One Point of Restraint"R"(MORE THAN 100 psi)CPVC NOMINALPIPE SIZE (IN.)"S"(LESS THAN 100 psi)TABLE "S" Two Points of Restraint"S"(MORE THAN 100 psi)34"1"114"112" - 3"0'-9"1'-0"1'-4"2'-0"0'-6"0'-9"1'-0"1'-0"34"1"114"112" - 3"4'-0"5'-0"6'-0"7'-0"3'-0"4'-0"5'-0"7'-0""R""R"MAXIMUM SUPPORT SPACING for CPVCALLOWABLE UNSUPPORTED DISTANCE TO DROPSFIRE SPRINKLER HEAD LEGEND116" = 1'-0"SCALE2FIRST FLOOR316" = 1'-0"SCALEN.T.SSCALE316" = 1'-0"SCALE54 BASE OF THE RISER1. GPM DISCHARGE2. RESIDUAL PRESSURE AT THE2. SPRINKLER PROTECTION AREASystem Demandserved by this riser:Basis of Designin calculated area:No. of SprinklersNo. of Sprinklers1. DENSITYLocationAT SOURCE3. PRESSURE REQUIREDHYDRAULIC-SYSTEMThis building is protectedby a Hydraulically DesignedAutomatic Sprinkler System.GPM/ft²AT SOURCE4. PRESSURE AVAILABLEAT SOURCE5. SURPLUS PRESSUREBEDROOM 221 gpm142.6 psi53.9 psi94.5 psi40.6 psi0.05BASE OF THE RISER1. GPM DISCHARGE2. RESIDUAL PRESSURE AT THE2. SPRINKLER PROTECTION AREASystem Demandserved by this riser:Basis of Designin calculated area:No. of SprinklersNo. of Sprinklers1. DENSITYLocationAT SOURCE3. PRESSURE REQUIREDHYDRAULIC-SYSTEMThis building is protectedby a Hydraulically DesignedAutomatic Sprinkler System.GPM/ft²AT SOURCE4. PRESSURE AVAILABLEAT SOURCE5. SURPLUS PRESSURECASITA26.6 gpm244 psi57.8 psi94.5 psi36.7 psi0.05MASTER BEDROOMGREAT ROOMKITCHEN1" RISER ASSEMBLY(SEE DETAIL #4)11" WATER METER1" COPPER "K"± 20'-0"112" PVC±68'-0"FIRE ALARM BELL23ACITY WATER MAIN 125ft²221ft²3EXTERIOR211ft²211ft²28ft²210ft²127ft²142ft²152ft²221ft²3EXTERIOR3EXTERIORINSPECTOR'S TEST VAKEYLESS HOSE BIB5'-0" AFF LABELED(FIELD VERIFYBEST LOCATION)201202ELECTRIC FIREALARM BELL1" BRASS RESIRISERW/ SPARE HEAD BOXG51,23' - 0 "2'-0"1'-0"3' - 0 "2'-0"2'-0"3' - 0 "1953EXTERIOR4' - 0 "0020010423BBORR008007MAIN DRAIN VALVEUSAGAUGECHECK VALVERISER MANIFOLD W/:(2) FLOW SWITCH(1) DRAIN AND TEST (3) PRESSURE GAUGE(4) SIGNS ON BODYSCUCLTESTANDDRAINFLOW1" ADAPTER SLIP X FIPTUL LISTED CPVC TO SYSTEM5 gpm to DOMESTIC ACCESS PANEL1" COPPER MIPI.F.P.POINT OF CONNECTION(E) MAIN 8.0ASSUMEDCORP. STOP1" COPPER "K"(20'-0" WORST CASE)1" CPVC112" PVC(68'-0" WORST CASE)PROVIDE A PERMANENT WARNING SIGN with MINIMUM 14" LETTERS ADJACENT to MAINSHUT-OFF STATING THE FOLLOWING:"WARNING: THE WATER SYSTEM TO THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRECERTAIN FLOWS AND PRESSURES TO FIGHT A FIRE. DEVICES THAT RESTRICT FLOW ORDECREASE the PRESSURE or AUTOMATICALLY SHUT OFF the WATER to the FIRE SYSTEM,SUCH as WATER SOFTENERS, FILTRATION SYSTEMS and AUTOMATIC SHUT-OFF VALVES, SHALLNOT be ADDED WITHOUT a REVIEW of the FIRE PROTECTION SPECIALIST.DO NOT REMOVE THIS SIGN. "☺SPARE HEAD BOX w/ 1 OF EACH TYPEAND INSTALLERS NAME & PHONE NUMBERIFP2-02-I13ABORR-IR-0DOMESTIC SHUT-OFF VALVE3BG51" WATER METER(FIRE + DOMESTIC)1" COPPER "L"(4'-0" WORST CASE)MAIN CONTROL VALVESYSTEM SENSORFLOW STITCHw/ RETARD10" ALARM BELLw/ CALL 911 SIGN(WIRING BY OTHERS)CAFFERY RESIDENCE HIDEAWAY 126 LA QUINTA CA 92253 80860 VIA PORTOFINO License #C16-711148 #DATEBYREVISIONSAUTHORITY HAVING JURISDICTION1RIVERSIDE COUNTY FIRE AUTHORITYPHONE:8779 COTTONWOOD AVE. SUITE #101 SANTEE, CA. 92071 PHONE: (619) 593-8200 FAX: (619) 593-9133JOB NUMBERDESIGNERDATEC8222DAVIN9/9/2021DESCRIPTIONSHEETCONTRACTOR: ADDRESS: PHONE: CAFFERY CAPITAL DEVELOPMENT LLC 73-241 HWY 111 STE. 1C 760-275-8800 (JOE) PALM DESERT CA. 92260 ARCHITECT: ADDRESS: PHONE: - - - -951-955-5282HYDRAULIC CALCULATIONS16'X16'4020'X20'403'-0" MINIMUM MEASURED FROMTHE CENTER OF THE FIXTURE TOTHE CENTER OF THE FIRE SPRINKLERTYPICAL INSTALLATION FORCEILING FAN OBSTRUCTIONNFPA 13D 8.2.5.1.1FIRE SPRINKLER PIPEFIRE SPRINKLER HANGERFIRE SPRINKLER HEADMINIMUM DISTANCE FROM FIRE SPRINKLERHEAD TO OBSTRUCTION ALONG WALLNFPA 13D 8.2.5.3.3(a)FIRE SPRINKLER PIPEFIRE SPRINKLER HANGERFIRE SPRINKLER HEADA (D - 8 in.) + B>_WHERE: D 30 in.>_WALLOBSTRUCTIONFP-1SITE PLANGENERAL NOTES1.WET PIPE SYSTEM DESIGNED PER 2016 NFPA 13D and/or 2019 CRC 313.3 and THE SPECIFIC REQUIREMENTS OF THE RIVERSIDE COUNTY FIRE AUTHORITY.2.ALL MATERIALS INSTALLED SHALL BE U.L. AND/OR F.M. LISTED "APPROVED" FOR FIRE PROTECTION USE,WHERE APPLICABLE.3.SYSTEM PIPING SHALL BE SUPPORTED PER REQUIREMENTS OF 2016 NFPA 13D and/or 2019 CRC 313.3 andMANUFACTURER'S SPECIFICATIONS, AS APPLICABLE.4.SYSTEM SHALL BE HYDROSTATICALLY TESTED FOR TWO HOURS AT 200 psi AND BE VISUALLYINSPECTED BY THE SERVING FIRE DEPARTMENT BEFORE ANY PIPING IS CONCEALED BY OTHER TRADES.5.ARRANGEMENT OF WATER SUPPLY SHALL BE PER 2016 NFPA 13D and/or 2019 CRC 313.3 and AS APPROVEDBY THE RIVERSIDE COUNTY FIRE AUTHORITY, MAIN SYSTEM CONTROL VALVE SHALL BE LOCATED AHEADOF LATERAL CONNECTION TO DOMESTIC WATER SERVICE ON COMBINED SYSTEMS6.SPACING OF SPRINKLERS SHALL BE:16'-0"- MAXIMUM FROM CENTER OF MULTIPLE HEADS IN A ROOM.8'-0"- MAXIMUM FROM FACE OF WALL IN ANY DIRECTION.8'-0"- MINIMUM FROM CENTER TO CENTER OF MULTIPLE RESIDENTIAL HEADS IN A ROOM.7.MINIMUM FLOW PER SPRINKLER SHALL BE CALCULATED AS FOLLOWS:TWO HEADS FLOWING:13.0 GPM PER SPRINKLER AT 16'x16' SPACING.ONE HEAD FLOWING:21.0 GPM PER SPRINKLER AT 20'x20' SPACING.8.PIPE SIZES AND TYPES SHALL BE AS FOLLOWS:RISER: - 1" RESI RISERSUPPLY MAINS:- 1 & 34" CPVCSPRINKLER LATERALS:- 34" CPVC9.SYMBOLS USED ON THIS PLAN:10SPRINKLERS ARE NOT TO BE INSTALLED IN THE FOLLOWING AREAS:A.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55ft² AND LESS. NFPA13D 8.3.2.B.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WITHINDWELLING UNITS THAT MEET ALL OF THE FOLLOWING CONDITIONS.(1)THE AREA OF THE SPACE DOES NOT EXCEED 24ft².(2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220. NFPA13D 8.3.3.C.SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. NFPA 13D 8.3.4.D.SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE, PENTHOUSE EQUIPMENTROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT, FLOOR / CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES. NFPA 8.3.5.E.SPRINKLERS SHALL NOT BE REQUIRED IN COVERED, UNHEATED PROJECTIONS OF THE BUILDING ATENTRANCES / EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. NFPA 13D 8.3.6.11.WHERE WATERFLOW ALARMS ARE PROVIDED, TEST CONNECTIONS SHALL BE INSTALLED AT LOCATIONSTHAT ALLOW FLOW TESTING OF WATER SUPPLIES, CONNECTIONS, AND ALARM MECHANISMS.12.ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE SEALED IN AN APPROVED MANNERTO MAINTAIN THE INTEGRITY OF THE ASSEMBLY.13.DRILLING AND NOTCHING OF STRUCTURAL MEMBERS SHALL BE PERFORMED IN STRICT ACCORDANCEWITH THE CALIFORNIA BUILDING CODE and MANUFACTURE GUIDELINES.14.WATER CALCULATIONSWATER AUTHORITY:COCHELLA VALLEY MUNICIPAL WATER DISTRICTNAME & NUMBER TO CONTACT:RUBEN MONTIEL (760-398-2651)STATIC PRESSURE:105-10%= 94.5psiMETER SIZE:1"RESIDUAL PRESSURE:89.5psiMETER LOSS:-4psi PER TWO HEAD CALCULATIONFLOW:500gpmUNDERGROUND SIZE:112" PVC TO SATISFY DEMANDDENOTES HYDRAULIC REFERENCENODE.DENOTES HYDRAULIC PIPE SEGMENT.DENOTES RESIDENTIAL FIRE SPRINKLERSSENJU RC RES 49SENJU RC RES 49RELIABLE F1 RES 49SS8464SS8464R3516MAKE and MODELSYMBSI#16'x16'16'x16'4.94.94.9K-FACSIZETEMPTYPEFINISHCANOPYQTYSPACING12"12"12"162°205°175°RESIDENTIALRESIDENTIALRESIDENTIALWHITEWHITEWHITECONCEALEDCONCEALEDSEMI-RECESS3541TOTAL HEAD COUNT - 4016'x16'20'x20'LEGAL DESCRIPTIONOWNER:ADDRESS:A.P.N:# OF STORIES:BUILDING TYPE:OCCUPANCY TYPE:TOTAL LIVING:TOTAL GARAGE:JOE CAFFERY73-241 HWY 111 SUITE 1C PALM DESERT CA. 92260777-140-0101VBR-3, U4,453ft²568ft²VICINITY MAPSCOPE: INSTALL A NEW FIRE SPRINKLER SYSTEM per NFPA 13Dfor a NEW SINGLE FAMILY DWELLING.1SECTION PLANRISER DETAILSPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55ft²AND LESS. per NFPA 13D 8.3.2FIRE SPRINKLER OMISSION LEGENDPER NFPA 13D1SPRINKLERS SHALL NOT BE REQUIRED IN COVERED, UNHEATEDPROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONGAS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS.per NFPA 13D 8.3.6SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS, AND PANTRIES WITHIN DWELLING UNITS THATMEET ALL OF THE FOLLOWING CONDITIONS.(1)THE AREA OF THE SPACE DOES NOT EXCEED 24ft².(2)THE WALLS AND CEILINGS ARE SURFACED WITHNONCOMBUSTIBLE OR LIMITED COMBUSTIBLEMATERIALS AS DEFINED BY NFPA 220.per NFPA13D 8.3.32342"KITCHEN RANGEFRONT of WALL-MOUNTED HOT AIRDIFFUSERSUNINSULATED HEAT DUCTSSIDE of CEILING or WALL-MOUNTEDHOT AIR DIFFUSERSUNISULATED HOT WATER PIPESHOT AIR FLUES60"36"MINIMUM DISTANCE FROM EDGEOF SOURCE TO ORDINARY-TEMPERATURE SPRINKLERHEAT SOURCECOAL or WOOD-BURNING STOVEWALL OVENFRONT of RECESSED FIREPLACE18"18"18"24"12"18"SIDE of OPEN or RECESSED FIREPLACEHOT WATER HEATER or FURNACELIGHT FIXTURE: 0 W - 250 WLIGHT FIXTURE: 250 W - 499 W36"6"6"12"12"36"12"MINIMUM DISTANCE FROM EDGEOF SOURCE TO INTERMEDIATE-TEMPERATURE SPRINKLER9"9"9"12"6"9"18"3"3"6"RATINGS of SPRINKLERS inSPECIFIED RESIDENTIAL AREASper 2016 NFPA 13D, Table 7.5.6.3HANG AND/OR SUPPORT CPVC PLASTIC PIPES TO WOODFRAMING WITH AFCON FASTENERS FOR WOOD, OBSERVINGSPECIFICATIONS AND SPACING RULES AS DEFINED IN CHARTSHOWN BELOWHARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLECPVC NOMINALPIPE SIZE (IN.)MAX. HANGERSPACING (FT.)FASTENERHEX HEAD SIZE34"Ø5'-6"516"1"Ø6'-0"516"114"Ø 6'-6"516"112"Ø7'-0"516"2"Ø8'-0"516"U.L. LISTED HANGERS FOR CPVC PLASTIC PIPEMEETS OR EXCEEDS THE REQUIREMENTS OFNFPA 13, 13R, & 13D SYSTEMS.2610 COMMERCE WAY, VISTA, CA, 92081 PHONE:800-854-1015 FAX: 800-924-5922HARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLEHARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLEHARDENED HEX HEAD SELF THREADINGSCREW IS FURNISHED WITH THE HANGER ANDIS THE MINIMUM FASTENER SIZE ACCEPTABLEHANGER SPACING for CPVCNo. 51O 2-HOLE FLAT STRAP HANGERNo. 551 SIDE-MOUNT HANGER No. 514 STAND-OFF NO-BLOCK HANGERNo. 515 DOUBLE OFFSET HANGERTYPICAL HANGERS for CPVCNominal PipeSize (ANSI)MaximumSupport Spacing34"5'-6"1"6'-0"114"6'-6"112"7'-0"2"8'-0"212"9'-0"3"10'-0"HANGER SPECIFICATIONS"S" MAXANYDISTANCECPVC NOMINALPIPE SIZE (IN.)"R"(LESS THAN 100 psi)TABLE "R" One Point of Restraint"R"(MORE THAN 100 psi)CPVC NOMINALPIPE SIZE (IN.)"S"(LESS THAN 100 psi)TABLE "S" Two Points of Restraint"S"(MORE THAN 100 psi)34"1"114"112" - 3"0'-9"1'-0"1'-4"2'-0"0'-6"0'-9"1'-0"1'-0"34"1"114"112" - 3"4'-0"5'-0"6'-0"7'-0"3'-0"4'-0"5'-0"7'-0""R""R"MAXIMUM SUPPORT SPACING for CPVCALLOWABLE UNSUPPORTED DISTANCE TO DROPSFIRE SPRINKLER HEAD LEGEND116" = 1'-0"SCALE2FIRST FLOOR316" = 1'-0"SCALEN.T.SSCALE316" = 1'-0"SCALE54 Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Required Pressure at Source (psi) Type of System Volume - Entire System (gal) 1 BEDROOM 2 NFPA 13D 0.053 400 400 1 0 5 26 53.9 Wet 19.8 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 10/1/2021 COCHELLA VALLEY WATER DISTRICT 1 Project Name : CAFFERY RESIDENCE Contract No. : C8222 Project Location: 80-860 VIA PORTOFINO City: LA QUINTA, CA 92253 Date: 9/10/2021 Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 Phone Number: 619-593-8200 Name of Designer: DAVIN BROOKS Authority Having Jurisdiction: RIVERSIDE FIRE AUTHORITY City: SANTEE, CA 92071 E-mail: DAVIN@IFPINC.NET Job Information Contractor Information Notes Date 10/4/2021 Page 1Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Job : CAFFERY RESIDENCE Hydraulic Analysis for : 1 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : 1 Flow (gpm)Pressure (psi) 0 94.5 500 89.5 Node at Source Static Pressure (psi) Residual Pressure (psi) Flow (gpm) Available Pressure (psi) Total Demand (gpm) Required Pressure (psi) Supply Analysis 1 94.5 89.5 500 94.5 26 53.9 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 5 0 0 5 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 21 0 0 21 Required Margin of Safety (psi) BOR - Pressure (psi) BOR - Flow (gpm) Demand w/o System Pump(s) 0 42.6 21 N/A Sprinklers Other Date 10/4/2021 Page 2Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Job : CAFFERY RESIDENCE Hydraulic Analysis for : 1 Date 10/4/2021 Page 3Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Job : CAFFERY RESIDENCE Hydraulic Analysis for : 1 Pressure (psi)Label Graph Labels Flow (gpm) Values Description 0S1 94.5Supply point #1 - Static 500S2 89.5Supply point #2 - Residual 0D1 4.8Elevation Pressure 26D2 53.9System Demand Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 36Supply94.5 40.6 26 Open Heads Head Ref. DensityDensity K-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required Calculated Head Type 195 4.9 0.05 20 18.4 0.053 18.421400Overhead Sprinkler Date 10/4/2021 Page 4Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Hydraulic CalculationsJob : CAFFERY RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 195 001 10 11 4.9 21 21 .75 0.874 1x(BM.Tee-Br)=3 1 3 4 150 0.2287 18.4 -0.4 0.9 001 042 11 11 -8.4 12.6 .75 0.874 8x(BM.Tee-Run)=8 3x(BM.Tee-Br)=9 5x(BM.90)=20 112.14 37 149.14 150 0.0887 18.9 0 13.2 042 R-O 11 4.08 8.4 21 1 1.101 2x(BM.90)=10 1x(BM.Tee-Run)=1 20.2 11 31.2 150 0.0743 32.1 3 2.3 R-O R-I 4.08 4 0 21 1 0 1 0 1 0 4.1575 37.4 0.0 4.2 BRASS RESI *** R-I BOR 4 2 0 21 1 1.101 2 0 2 150 0.0743 41.6 0.9 0.1 BOR 3B 2 1 0 21 1 1.025 1 0 1 150 0.1053 42.6 0.4 0.1 3B 3A 1 -1 5 26 1 1.025 1x(us.90)=2.7 3 2.7 5.7 150 0.1563 43.2 0.9 0.9 3A 2-O -1 -1 0 26 1.5 1.598 1x(BM.90)=8 67.58 8 75.58 150 0.018 44.9 0 1.4 2-O 2-I -1 -1 0 26 1 0 0.75 0 0.75 0 5.3333 46.3 0 4 METER *** 2-I 1 -1 -1 0 26 1 0.995 20 0 20 150 0.1806 50.3 0 3.6 1 53.9 2Path No: G5 3B 1 1 5 5 1 1.025 1x(us.Tee-Br)=6.75 0.5 6.75 7.25 150 0.0074 43.1 0 0.1 3B 43.2 3Path No: 001 002 11 11 0 8.4 .75 0.874 1x(BM.90)=4 5.54 4 9.54 150 0.042 18.9 0 0.4 002 042 11 11 0 8.4 .75 0.874 18x(BM.Tee-Run)=18 3x(BM.Tee-Br)=9 14x(BM.90)=56 222.84 83 305.84 150 0.042 19.3 0 12.8 042 32.1 Date 10/4/2021 Page 5Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Hydraulic CalculationsJob : CAFFERY RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. *** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. * Maximum Velocity of 11.24 ft/s occurs in the following pipe(s): (001-195) Date 10/4/2021 Page 6Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Device GraphsJob : CAFFERY RESIDENCE Date 10/4/2021 Page 7Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Device GraphsJob : CAFFERY RESIDENCE Date 10/4/2021 Page 8Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Required Pressure at Source (psi) Type of System Volume - Entire System (gal) 2 CASITA NFPA 13D 0.051 512 256 2 0 5 31.6 57.8 Wet 20 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 10/1/2021 COCHELLA VALLEY WATER DISTRICT 1 Project Name : CAFFERY RESIDENCE Contract No. : C8222 Project Location: 80-860 VIA PORTOFINO City: LA QUINTA, CA 92253 Date: 9/10/2021 Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 Phone Number: 619-593-8200 Name of Designer: DAVIN BROOKS Authority Having Jurisdiction: RIVERSIDE FIRE AUTHORITY City: SANTEE, CA 92071 E-mail: DAVIN@IFPINC.NET Job Information Contractor Information Notes Date 10/4/2021 Page 9Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Job : CAFFERY RESIDENCE Hydraulic Analysis for : 2 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : 1 Flow (gpm)Pressure (psi) 0 94.5 500 89.5 Node at Source Static Pressure (psi) Residual Pressure (psi) Flow (gpm) Available Pressure (psi) Total Demand (gpm) Required Pressure (psi) Supply Analysis 1 94.5 89.5 500 94.5 31.6 57.8 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 5 0 0 5 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 26.6 0 0 26.6 Required Margin of Safety (psi) BOR - Pressure (psi) BOR - Flow (gpm) Demand w/o System Pump(s) 0 44 26.6 N/A Sprinklers Other Date 10/4/2021 Page 10Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Hydraulic CalculationsJob : CAFFERY RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 202 008 12 13 4.9 13 13 .75 0.874 1x(BM.Tee-Run)=1 1x(BM.Tee-Br)=3 7.73 4 11.73 150 0.0935 7 -0.4 1.1 008 042 13 11 -0.7 12.3 .75 0.874 16x(BM.Tee-Run)=16 3x(BM.Tee-Br)=9 11x(BM.90)=44 192.23 69 261.23 150 0.0847 7.7 0.9 22.1 042 R-O 11 4.08 14.3 26.6 1 1.101 2x(BM.90)=10 1x(BM.Tee-Run)=1 20.2 11 31.2 150 0.1145 30.7 3 3.6 R-O R-I 4.08 4 0 26.6 1 0 1 0 1 0 5.6174 37.2 0.0 5.6 BRASS RESI *** R-I BOR 4 2 0 26.6 1 1.101 2 0 2 150 0.1145 42.9 0.9 0.2 BOR 3B 2 1 0 26.6 1 1.025 1 0 1 150 0.1623 44 0.4 0.2 3B 3A 1 -1 5 31.6 1 1.025 1x(us.90)=2.7 3 2.7 5.7 150 0.2234 44.6 0.9 1.3 3A 2-O -1 -1 0 31.6 1.5 1.598 1x(BM.90)=8 67.58 8 75.58 150 0.0257 46.7 0 1.9 2-O 2-I -1 -1 0 31.6 1 0 0.75 0 0.75 0 5.3333 48.7 0 4 METER *** 2-I 1 -1 -1 0 31.6 1 0.995 20 0 20 150 0.2581 52.7 0 5.2 1 57.8 2Path No: 201 007 12 13 4.9 13.6 13.6 .75 0.874 1x(BM.Tee-Br)=3 1 3 4 150 0.102 7.7 -0.4 0.4 007 042 13 11 0.7 14.3 .75 0.874 10x(BM.Tee-Run)=10 3x(BM.Tee-Br)=9 9x(BM.90)=36 143.44 55 198.44 150 0.1115 7.7 0.9 22.1 042 30.7 3Path No: G5 3B 1 1 5 5 1 1.025 1x(us.Tee-Br)=6.75 0.5 6.75 7.25 150 0.0074 44.5 0 0.1 3B 44.6 Date 10/4/2021 Page 11Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Hydraulic CalculationsJob : CAFFERY RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 4Path No: 008 007 13 13 0 0.7 .75 0.874 1x(BM.Tee-Run)=1 4.85 1 5.85 150 0.0004 7.7 0 0 007 7.7 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. *** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. * Maximum Velocity of 13.02 ft/s occurs in the following pipe(s): (1-2-I) Date 10/4/2021 Page 12Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Device GraphsJob : CAFFERY RESIDENCE Date 10/4/2021 Page 13Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg Device GraphsJob : CAFFERY RESIDENCE Date 10/4/2021 Page 14Copyright © 2002-2012 Tyco Fire Protection Products File: Y:\ENGINEERING\3A.Project Files\C8222 CAFFRE RESIDENCE\C8222 CAFFERY_THIS ONE.dwg ©2019 National Fire Products 0819 1342881 Pre-assembled, compact fire sprinkler riser unit for residential sprinkler systems Features & Benefits Technical Data Dimensions Components • Manifold is manufactured as a one- piece casting that is air-tested for leaks • Raised lettering on both sides allows installation to the right or left and easily identifies the flow direction and test and drain outlet • Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring • Flow switch has dual SPDT switches and a retard of 0–90 seconds • Optional "all-in-one" cost-saving combination pressure relief valve/test and drain valve is available • Unique, compact design allows installation within standard frame construction and in tighter spaces • Sizes: 1", 1-1/4", 1-1/2", 2" • Style: Thread x thread • Riser Body Finish: Cast brass • Water Pressure Gauge: 0–300 psi • Optional Accessories: 175 psi pressure relief valve/test and drain • In accordance with NFPA 13, 13R and 13D • Flow switch and pressure gauge are UL Listed DESCRIPTION 1 Manifold body, male thread x male thread 2 Inline check valve, spring-loaded 3 Flow switch with retard 4 Drain valve, with optional pressure relief valve 5 Pressure gauge, 0–300 psi Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve **With or without pressure relief valve Resi-riser ™ DESCRIPTION 1"1-1/4"1-1/2"2" A Height*13"13"13"13" B Width**11"12"12-1/4"12-3/4" C Depth 3-1/2"3-1/2"3-1/2"3-1/2" –Drain Size 1/2"1"1"1" 1 2 3 5 4 C A B ©2019 National Fire Products 0819 1342881 PART #WITH INLINE CHECK VALVE WITH SWING CHECK VALVE WITH PRESSURE RELIEF VALVE WITH CPVC ADAPTERS 1" SR100-IR4 ✓ SR100-R4 SR100-SR4 ✓ SR100-IRR4 ✓✓ SR100-SRR4 ✓✓ SR100-IR4-TD ✓✓ SR100-SR4-TD ✓✓ SR100-IRR4-TD ✓✓✓ SR100-RR4-TD ✓✓ SR100-SRR4-TD ✓✓✓ 1-1/4" SR125-IR4 ✓ SR125-R4 SR125-SR4 ✓ SR125-IRR4 ✓✓ SR125-SRR4 ✓✓ SR125-IR4-TD ✓✓ SR125-SR4-TD ✓✓ SR125-IRR4-TD ✓✓✓ SR125-RR4-TD ✓✓ SR125-SRR4-TD ✓✓✓ 1-1/2" SR150-IR4 ✓ SR150-R4 SR150-SR4 ✓ SR150-IRR4 ✓✓ SR150-SRR4 ✓✓ SR150-IR4-TD ✓✓ SR150-SR4-TD ✓✓ SR150-IRR4-TD ✓✓✓ SR150-RR4-TD ✓✓ SR150-SRR4-TD ✓✓✓ 2" SR200-IR4 ✓ SR200-R4 SR200-SR4 ✓ SR200-IRR4 ✓✓ SR200-SRR4 ✓✓ SR200-IR4-TD ✓✓ SR200-SR4-TD ✓✓ SR200-IRR4-TD ✓✓✓ SR200-RR4-TD ✓✓ SR200-SRR4-TD ✓✓✓ RESI-riser ™ Model Numbers ©2019 National Fire Products 0819 1342881 How It works: Pressure Relief/Test & Drain Normal Position: Static pressure Relieving pressure exceeding 175 psi Manual Open: Drain or flow switch test Locked closed for hydrostatic test 0102030405060708090100 2 4 6 8 10 12 Flow (gpm)Pressure (psi)1-1/4"1"1-1/2"2" Pressure Loss RESI-riser ™ ©2019 National Fire Products 0819 1342881 Inline spring check valve RESI-riser ™ Dimensions Components DESCRIPTION MATERIAL 1 Nut Stainless Steel 2 Spring Cap Stainless Steel 3 Spring Stainless Steel 4 O-Ring Seat Rubber 5 Clapper, Spring-Loaded Brass 6 Body Brass 7 Washer Teflon™ 1"1-1/4"1-1/2"2" A 1-9/16"2"2-1/8"2-3/4" B 3-1/4"3-5/8"4"5" C 1-3/16"1-9/16"1-3/4"2-3/16" 5 5 6 4 7 3 2 1 1 C B FLOWA BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet Page 1 of 2 AUGUST 2018 TFP1915 Worldwide Contacts www.tyco-fire.com IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. General Description TYCO CPVC Pipe and Fittings pro- duced by Johnson Controls are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art addi- tives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch to 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved (Refer to Installation Handbook IH-1900 dated April 2016 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900. TFP1915 Page 2 of 2 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; BLAZEMASTER is a trademark of The Lubrizol Corporation 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 © 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Page:1 of 8 Document No.U085166 Date:Jul/08/2019 SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Page:2 of 8 Document No.U085166 Date:Jul/08/2019 TECHNICAL DATA Approvals: cULus Listed, NSF-61-G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPM/psi1/2 (70.6 LPM/bar1/2) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Plate 205°F (96°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (72°C): Uncolored 175°F (79°C): White 205°F (96°C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (72°C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1-1 FIGURE 1. Model RC-RES K=4.9 FIGURE 1-1. Marking (Color Code) OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) FIGURE 2. OPERATION PROCESS (The figure is for illustrative purposes only) Page:3 of 8 Document No.U085166 Date:Jul/08/2019 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as few as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C) 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) Intermediate 205°F (96°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Page:4 of 8 Document No.U085166 Date:Jul/08/2019 Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: ・ The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. ・ A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Intermediate Temperature Rating 205°F (96°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) ― ― 13 (49.2) 7.0 (0.48) 18×18 (5.5×5.5) 18 (5.5) 17 (64.4) 12.0 (0.83) ― ― 17 (64.4) 12.0 (0.83) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) ― ― 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) Page:5 of 8 Document No.U085166 Date:Jul/08/2019 INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft·lbs (9.5 to 19.0 N·m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Remover RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. FIGURE 3. INSTALLATION FIGURE 4. RATCHET & SOCKET Page:6 of 8 Document No.U085166 Date:Jul/08/2019 FIGURE 5. PROTECTIVE CAP REMOVAL FIGURE 6. INSTALLATION (COVER PLATE ASSEMBLY) FIGURE 7. INSTALLATION (CORRECT and INCORRECT) Page:7 of 8 Document No.U085166 Date:Jul/08/2019 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F / 4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under TABLE A “Hydraulic Design Criteria”). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Limited Warranty For details of warranty, refer to Sales Contract. Page:8 of 8 Document No.U085166 Date:Jul/08/2019 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) or 205°F (96°C)) Cover Plate Assembly 2-5/8 inch (φ68mm) or 3-1/4 inch (φ83mm) or 2-5/8 inch square (□68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Copper Wood Grain Custom Color Custom Pattern 2-5/8" Round, 140°F ○ ○ - - - - - - ○ ○ 3-1/4" Round, 140°F ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 2-5/8" Square, 140°F ○ - - - - - - - ○ ○ 2-5/8" Round, 162°F ○ - - - - - - - ○ ○ 3-1/4" Round, 162°F ○ - - - - - - - ○ ○ Tools for Installation of Model RC-RES ・Socket NR-H For use with a 3/8” drive ratchet (not included) ・Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) ・Cap Remover RC Model F1Res Series Glass Bulb Residential Sprinklers For NFPA 13, NFPA 13R, and NFPA 13D Applications Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations • Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model F1Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model F1Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1Res residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Bulletin 135 October 2018 www.reliablesprinkler.com Residential Sprinkler Summary Sprinkler Model Sprinkler Identification Number (SIN) Orientation K-Factor gpm/psi1/2 (lpm/bar1/2) Thread Size NPT or ISO7-1 Installation Options Max. Coverage Area ft x ft (m x m) F1Res30 R3511 Pendent 3.0 (43)1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9 (71)1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res58 R3513 Pendent 5.8 (84)1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res76 R7618 Pendent 7.6 (109)3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res30 CCP R3511 Pendent 3.0 (43)1/2 Conical Concealed or Recessed 14 x 14 (4.3 x 4.3) F1Res49 CCP R3516 Pendent 4.9 (71)1/2 Conical Concealed or Recessed 20 x 20 (6.1 x 6.1) F1Res58 CCP R3513 Pendent 5.8 (84)1/2 Conical Concealed or Recessed 20 x 20 (6.1 x 6.1) F1Res76 CCP R7618 Pendent 7.6 (109)3/4 Conical Concealed or Recessed 20 x 20 (6.1 x 6.1) F1Res44 HSW R3531 Horizontal Sidewall 4.4 (63)1/2 Recessed 16 x 20 (4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4 (63)1/2 Conical Concealed 16 x 20 (4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8 (84)1/2 Recessed 16 x 20 (4.9 x 6.1) F1Res 58 HSWX RA3533 Horizontal Sidewall 5.8 (84)1/2 Recessed 14 x 26 (4.3 x 7.9) Table A Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ min), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1Res Series sprinklers are listed for use in wet systems only. cULus Listed Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions Figure 1 * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res30 Residential Pendent Sprinkler & Models F2 & FV Escutcheon SIN R3511 Bulletin 135 October 2018 Page 2 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft.(m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)8 (30)7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3)10 (38)11.0 (0.76) 15 x 15 (4.6 x 4.6)12 (45)16.0 (1.1) 16 x 16 (4.9 x 4.9)13 (49)18.8 (1.3) Table BModel F1Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res49 Residential Pendent Sprinkler Components and Installation Dimensions Figure 2 Model F1Res49 Residential Sprinkler & Models F1, F2, & FV Escutcheons SIN R3516 Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F1 Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Bulletin 135 October 2018 Page 3 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)13 (49)7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)13 (49)7.0 (0.48) 18 x 18 (5.5 x 5.5)17 (64)12.0 (0.83) 20 x 20 (6.1 x 6.1)20 (76)16.7 (1.15) 12 x 12 (3.7 x 3.7)15 (57)9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3)16 (61)10.7 (0.74) 16 x 16 (4.9 x 4.9)17 (64)12.0 (0.83) 18 x 18 (5.5 x 5.5)19 (72)15.0 (1.03) 20 x 20 (6.1 x 6.1)22 (83)20.2 (1.39) Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Table C Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res58 Residential Pendent Sprinkler & F1, F2, & FV Recessed Escutcheons SIN R3513 Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F1 Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res58 Residential Pendent Sprinkler Components and Installation Dimensions Figure 3 Bulletin 135 October 2018 Page 4 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9)16 (61)7.6 (0.52) 1 to 4 inches (25 to 100 mm)18 x 18 (5.5 x 5.5)19 (72)10.8 (0.75) 20 x 20 (6.1 x 6.1)22 (83)14.4 (1.0) Model F1Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Table D Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res76 Residential Pendent Sprinkler & F1, F2, & FV Escutcheons SIN R7618 Technical Specifications Style: Pendent and Recessed Pendent Threads: 3/4” NPT or ISO7-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F1 Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res76 Residential Pendent Sprinkler Components and Installation Dimensions Figure 4 * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Bulletin 135 October 2018 Page 5 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 18 x 18 (5.5 x 5.5)21 (80)7.6 (0.52)1 to 4 inches (25 to 100 mm)20 x 20 (6.1 x 6.1)23 (87)9.2 (0.63) Model F1Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Table E Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res30 CCP Conical Concealed Pendent & Model FP Recessed Escutcheon Pendent Sprinkler SIN R3511 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model GFR2 Model F1Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Figure 5 *Note: Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Bulletin 135 October 2018 Page 6 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)8 (30)7.0 (0.48)1/2 to 1 inch (13 to 25 mm)14 x 14 (4.3 x 4.3)11 (38)13.4 (0.92) Model F1Res30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria Table F Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Model F1Res49 CCP Conical Concealed Pendent & Model FP Recessed Escutcheon Pendent Sprinkler SIN R3516 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model GFR2 Model F1Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions Figure 6 Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 14 x 14 (4.3 x 4.3)13 (49)7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16 x 16 (4.9 x 4.9)14 (53)8.2 (0.57) 18 x 18 (5.5 x 5.5)18 (68)13.5 (0.93) 20 x 20 (6.1 x 6.1)20 (76)16.7 (1.15) Model F1Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Table G Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Bulletin 135 October 2018 Page 7 of 15 www.reliablesprinkler.com Model F1Res58 CCP Conical Concealed Pendent & Model FP Recessed Escutcheon Pendent Sprinkler SIN R3513 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) Figure 7Model F1Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9)16 (61)7.6 (0.52) 1/2 to 1 inch (13 to 25 mm)18 x 18 (5.5 x 5.5)19 (72)10.8 (0.75) 20 x 20 (6.1 x 6.1)22 (83)14.4 (1.0) Model F1Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Table H *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 October 2018 Page 8 of 15 www.reliablesprinkler.com Figure 8Model F1Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Model F1Res76 CCP Conical Concealed Pendent and Model FP Recessed Escutcheon Pendent Sprinkler SIN R7618 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4” NPT or ISO7-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9)21 (80)7.6 (0.52) 1/2 to 1 inch (13 to 25 mm)18 x 18 (5.5 x 5.5)22 (83)8.4 (0.58) 20 x 20 (6.1 x 6.1)25 (95)10.8 (0.75) Model F1Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Table I *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 October 2018 Page 9 of 15 www.reliablesprinkler.com Model F1Res44 Horizontal Sidewall Sprinkler & Models FV & F2 Recessed Escutcheon SIN R3531 Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)12 (45)7.5 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3)14 (53)10.2 (0.70) 15 x 15 (4.6 x 4.6) 15 (57)11.6 (0.80) 16 x 16 (4.9 x 4.9)16 (61)13.3 (0.92) 16 x 18 (4.9 x 5.5)18 (68)16.8 (1.16) 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89) 18 x 18 (5.5 x 5.5)19 (72)18.7 (1.29) 12 x 12 (3.7 x 3.7)14 (53)10.2 (0.7) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3)16 (61)13.2 (0.91) 15 x 15 (4.6 x 4.6)16 (61)13.2 (0.91) 16 x 16 (4.9 x 4.9)17 (64)15.0 (1.03) 16 x 18 (4.9 x 5.5)20 (76)20.7 (1.43) 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89) Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table J Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res44 Horizontal Sidewall Sprinkler Installation Dimensions Figure 9 Bulletin 135 October 2018 Page 10 of 15 www.reliablesprinkler.com Note: (1) Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2) 135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers (3) 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C)Deflector to Ceiling DistanceFlow gpm (l/min) Pressure psi (bar) Flow gpm (l/min) Pressure psi (bar) 12 x 12 (3.7 x 3.7)13 (49)8.7 (0.60)14 (53)10.2 (0.7) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3)14 (53)10.2 (0.7)14 (53)10.2 (0.7) 15 x 15 (4.6 x 4.6)16 (61)13.2 (0.91)– –– – 16 x 16 (4.9 x 4.9)17 (64)15.0 (1.03)– –– – 16 x 18 (5.5 x 5.5)19 (72)18.7 (1.31)– –– – 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89)– –– – 12 x 12 (3.7 x 3.7)14 (53)10.2 (0.7)– –– – 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3)15 (57)11.7 (0.81)– –– – 15 x 15 (4.6 x 4.6)17 (64)15.0 (1.03)– –– – 16 x 16 (4.9 x 4.9)18 (68)16.8 (1.16)– –– – 16 x 18 (4.9 x 5.5)20 (76)20.7 (1.43)– –– – Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table K Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. SWC SWC-2 Bulletin 135 October 2018 Page 11 of 15 www.reliablesprinkler.com Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler SIN R3531 Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) (1) Cover Plates SWC Conical Concealed Plate(2) SWC-2 (Slotted) Conical Concealed Plate(3) Sprinkler Wrenches Model GFR2 Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions Figure 10 Model F1Res58 Horizontal Sidewall Sprinkler & Models F2 & FV Recessed Escutcheon SIN R3533 Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)16 (61)7.6 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3)18 (68)9.7 (0.66) 15 x 15 (4.6 x 4.6)19 (72)10.7 (0.74) 16 x 16 (4.9 x 4.9)21 (80)13.2 (0.91) 16 x 18 (5.5 x 5.5)25 (95)18.6 (1.28) 16 x 20 (4.9 x 6.1)29 (110)25.0 (1.72) 12 x 12 (3.7 x 3.7)22 (83)14.4 (1.0) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3)22 (83)14.4 (1.0) 15 x 15 (4.6 x 4.6)24 (91)17.1 (1.18) 16 x 16 (4.9 x 4.9)26 (98)20.1 (1.39) 16 x 18 (4.9 x 5.5)31 (117)28.6 (1.97) Model F1Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table L Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions Figure 11 Bulletin 135 October 2018 Page 12 of 15 www.reliablesprinkler.com Model F1Res58 HSWX Horizontal Sidewall Sprinkler & Models F2 & FV Recessed Escutcheon SIN RA3533 Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20 (5.5 x 6.1)30 (114)26.8 (1.85) 4 to 6 inches (100 to 150 mm) 20 x 20 (6.1 x 6.1)30 (114)26.8 (1.85) 16 x 22 (4.9 x 6.7)33 (125)32.4 (2.23) 16 x 24 (4.9 x 7.3)38 (144)42.9 (2.96) 14 x 26 (4.3 x 7.9)42 (160)52.4 (3.63) 18 x 20 (5.5 x 6.1)35 (133)36.4 (2.51) 6 to 12 inches (150 to 300 mm) 16 x 22 (4.9 x 6.7)38 (144)42.9 (2.96) 16 x 24 (4.9 x 7.3)42 (160)52.4 (3.61) 14 x 26 (4.3 x 7.9)46 (174)62.9 (4.34) Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table M Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Figure 12 Bulletin 135 October 2018 Page 13 of 15 www.reliablesprinkler.com Installation Models F1Res sprinklers are to be installed as shown in this bulletin. Model F1, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1Res sprinklers. Not all F1Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC–2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model GFR2 Model W2 Installation of F1Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4” (57 mm) for F1 or F2 recessed escutcheons; or 2-5/8” (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC–2 cover plates. Install F1Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and “Top” marking must face the ceiling. A ‘leak tight” sprinkler joint can be obtained with the following torque: • 1/2” NPT and ISO7-1R1/2: 8-18 ft-lbs (11 – 24 N-m) • 3/4” NPT and ISO7-1R3/4: 14-20 ft-lbs (19 – 27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC–2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Table N Standard Finishes Special Application Finishes Sprinkler(1)F1, F2. FV, FP(3), Escutcheons CCP, SWC (Conical) Cover Plates (1)Sprinkler (1)F1, F2. FV, FP(3), Escutcheons CCP, SWC (Conical) Cover Plates (1) Bronze Brass --Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White Polyester (2) White Polyester White Paint Black Polyester (2) Black Polyester Black Paint ------Custom Color Polyester Custom Color Polyester Custom Color Paint ------Electroless Nickel PTFE (2)---- Notes: (1) Paint or any other coating applied over the factory finish will void all approvals and warranties. (2) cULus Listed Corrosion Resistant. (3) The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Finishes Bulletin 135 October 2018 Page 14 of 15 www.reliablesprinkler.com P/N 9999970235Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model (See Table A) • Temperature Rating • Threads (NPT or ISO7-1) • Finish (See Table N) Escutcheon or Cover Plate • Model • Finish (See Table N) Sprinkler Wrench • Model W2 (Pendent and HSW) • GFR2 (Recessed and Concealed) Bulletin 135 October 2018 Page 15 of 15 www.reliablesprinkler.com data sheet The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM CPVC TWO HOLE STRAP Galvanized steel construction Designed for support or restraint fo piping in either a vertical or horizon- tal position. It can be used on top or bottom of a beam. The edges are flared to provent any damage to the CPVC pipe. It is easily attached using 2 hex head self-threading screws (supplied) Galvanized steel, supplied with hex slotted screws size 3/4” 1” 1-1/4” 1-1/2” 2” part # 25-30-283 25-30-284 25-30-285 25-30-286 25-30-287 1. SNAP CPVC PIPE INTO HANGER. 2. MOUNT HANGER TO UNDERSIDE OF BEAM WITH SCREWS PROVIDED. 3. MAY ALSO BE USED ON TOP SIDE OF BEAM. HEX HEAD SCREWS C US File VIXH.EX6587 511 SIDE MOUNT CPVC - COPPER HANGER SIZE MATERIAL FINISH FUNCTION INSTALLATION , WOOD #905 STEEL FEATURES #905 ORDERING - 3/4" thru 2" pipe. - Carbon Steel. - Mil. Galvanized. - Hanger on CPVC and Copper pipe. - Per NFPA13, 13R 13D and CPVC manufacturers instructions on top or bottom of beam. Space by pipe type in : CPVC pipe - Copper pipe - screw - no pre-drill. in CPVC pipe - Copper pipe - 1/4 or #14 Tek Screw. * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required screw has 5/16" hex head - included. - Part # and pipe size. ” AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 FASTENERS #905 - - UL Listed per NFPA13. 3/4" - 2" screw - no pre-drill. 3/4" - 2" min. 18 GA. 3/4" - 2" 1/4 or #14 Tek Screw. 3/4" - 2" SPECIALNOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. ” Side View - For Drawings Below Hanger - Metal Stud Hanger - Wood Stud Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org CAD The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC NPS 3/4” 1” 1-1/4” 1-1/2” 2” •For mounting CPVC pipe to wood •Flared edges help protect CPVC •Galvanized steel •Supplied with #10 x 1” hex head cap screws •Complies with the static load requirements of NFPA® 13 • Suitable for fire protection installations • Eliminates spacers or backup blocks • Easy installation A 2.69” 2.94” 3.31” 3.56” 4.06” B 3.25” 3.25” 3.25” 4.5” 5” MAX. HANGER SPACING 67” 70” 79” 82” 94” 1” .25” A B Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minimum 3/8” thickness. Can only be used as a guide on top of beam or on vertical piping. May be installed to wood using supplied fastener or into (minimum 18 gauge) steel using two 1/4" x 1" TEK type screws. Provides vertical/lateral restraint and prevents upward movement of the pipe that supplies pendant fire sprinkler below ceiling. All sizes can be used as a restrainer in the bottom position. The 3/4” size only can be used as a restrainer in the top position. Installation: Per NFPA 13, 13R and 13D. (see page two) top mount bottom mount side mount Fasteners: Wood - 3/4” to 3” CPVC Pipe - wood screw - no pre-drill 3/4” to 2” Copper Pipe - wood screw - no pre-drill 3/4” to 2” Steel Pipe - 1/4” x 1-1/2” lag screw - no pre-drill Steel - 3/4” to 3” CPVC Pipe - 1/4” TEK screw 3/4” to 2” Copper Pipe - 1/4” TEK screw 3/4” to 2” Steel Pipe - 1/4” TEK screw For use as a restrainer in all sizes when attached to the bottom of structural wood members. For use as a restrainer in the 3/4 inch size when attached to the top of structural wood members ARGCO MODEL # 2530180 data sheet Designed to mount CPVC pipe to wood or composite wood joists with a minumum 3/8” thickness. 1. Snap strap over CPVC pipe. 2. Squeeze strap back around pipe. Allowing pipe to slide back and forth. 3. Fasten the strap to the wood surface using the two hex head screws provided. NOTE: All sizes can be used as a restrainer in the bottom position. The 3/4” size only can be used as a restrainer in the top position. All safety regulations required by the jobsite must be observed. •Observe all federeal and local safety regulations •Wear safety glasses and hard hat at all times •Be aware of personnel working above and below •Wear gloves to avoid splinters and cuts. •When working above ground , be sure the structure will support your weight. STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC INSTALLATION INSTRUCTIONS FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Hanger & surge restraint for horizontal CPVC piping when installed on the side of supporting structure. •For mounting CPVC pipe to wood •Flared edges help protect CPVC •Galvanized steel construction •Supplied with #10 hex head cap screws •Complies with the static load requirements of NFPA® 13 •Suitable for fire protection installations •Size Range: 3/4" through 1" Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minumum 3/8” thickness. Offset edge eliminates abrasion. Installation: Per NFPA 13, 13R and 13D. Install into wood or steel. Slides onto CPVC pipe. 3/4" pipe size | Item #2530181-3/4 1" pipe size | Item #2530181-1 CPVC PIPE HANGER SUPPORT DOUBLE OFFSET DESIGN System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com Updated 4/16/2019 © ARGCO OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org September 15, 2022 Innovative Fire Protection Re: Residential Fire Sprinkler Plan Review – Caffrey Residence FSS2022-0295 (80860 Via Portofino) The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Rebecca Winscott - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 80860 Via Portofino PERMIT#: FSS2022-0294 DATE ISSUED: 9-15-22 DESCRIPTION: Caffrey Residene CONTRACTOR: Innovative Fire Protection HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.