Loading...
FSS2022-0320ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SIMON CHAVERO 82417 priscilla ct indio CA 92201 (760)574-6512 simon@silveradofire.c om CONTRACTOR SILVERADO FIRE PROTECTION 82417 PRISCILLA STREET INDIO CA 92201 (760)574-6512 SIMON@SILVERADOFI RE.COM OWNER JERRY SANTUCCI 48220 VIA VALLARTA LA QUINTA CA 92253 (760)574-6512 CONDITIONS Description: TRINITY PALMS /FIRE SPRINKLERS / BRES2022-0432 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 9/21/2022 AMA Parcel No: 602111034 Site Address: 48230 VIA VALLARTA LA QUINTA,CA 92253 Approved: 9/21/2022 RWI Subdivision: TR 27835 Block: Lot: 2 Issued: 11/23/2022 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/13/2023 LRO Valuation: $11,700.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, September 27, 2023 10:02:57 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0320 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO LRO 11/23/2022 11/23/2022 APPROVED OVERHEAD ROUGH PIPING LRO 11/23/2022 11/23/2022 APPROVED See Notes Revised Plans and Calcs prior to final due to Inspector LR finding a 3/4 inch water meter when plans show 1 inch. FIRE FINAL**LRO 7/13/2023 7/13/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 11/23/22 WEB13681 758268345 CREDIT simon chavero EPRS FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 11/23/22 WEB13681 758268345 CREDIT simon chavero EPRS Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/23/22 WEB13681 758268345 CREDIT simon chavero EPRS Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 11/23/22 WEB13681 758268345 CREDIT simon chavero EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Wednesday, September 27, 2023 10:02:57 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0320 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/21/2022 Etrakit Public Registration 1ST SUBMITTAL SPRINKLER SPECS VK-494 4.9 k Res 155 deg (2).pdf 1 DOC 9/21/2022 Etrakit Public Registration 1ST SUBMITTAL PLAN FP-2 Duplex La Quinta - Sheet - FP-2 - Piping Plan (1).pdf 1 DOC 9/21/2022 Etrakit Public Registration 1ST SUBMITTAL PLAN FP-1 Duplex La Quinta.pdfSite Plan (1).pdf 1 DOC 9/21/2022 Etrakit Public Registration 1ST SUBMITTAL CVWD Results (1) (2).pdf 1 DOC 9/21/2022 Etrakit Public Registration 1ST SUBMITTAL HYDRAULIC CALCS 3 Document.pdfCalc-3.pdf 1 DOC 9/21/2022 Etrakit Public Registration 1ST SUBMITTAL HYDRAULIC CALCS 1 Document.pdfCalc-1 (3).pdf 1 DOC 9/21/2022 Etrakit Public Registration 1ST SUBMITTAL HYDRAULIC CALCS 4 Document.pdfCalc-4.pdf 1 DOC 6/27/2023 Etrakit Contractor VK-494 4.9 k Res 155 deg (6).pdf 1 DOC 6/27/2023 Etrakit Contractor Results (1) (4).pdf 1 DOC 6/27/2023 Etrakit Contractor Document.pdfCalc-3 (3).pdf 1 BOND INFORMATION 1ST FIRE - ETRAKIT (2 WK) REBECCA WINSCOTT 9/21/2022 9/21/2022 APPROVED 1ST PERMIT TECH – ETRAKIT (1 DAY) ARMANDO MAGALLON 9/21/2022 9/21/2022 COMPLETE I HAVE DUPLICATED AN ADDITIONAL FSS PERMIT FOR INSPECTION AS WELL AS RECORD KEEPING PURPOSES. THE ATTACHED PLANS WERE ALL MOVED OVER FROM FSS2022-0307 FOR REVIEW. 2ND FIRE (1 WK)KOHL HETRICK 6/27/2023 7/4/2023 7/10/2023 APPROVED AS-BUILTS (NO FEE) Printed: Wednesday, September 27, 2023 10:02:57 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0320 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/27/2023 Etrakit Contractor Document.pdfCalc-1 (14).pdf 1 DOC 6/27/2023 Etrakit Contractor Duplex La Quinta.pdfPiping (1) (1).pdf 1 DOC 7/10/2023 KOHL HETRICK FSS2022-0320 - AS- BUILTS APPROVED.pdf FSS2022-0320 - AS- BUILTS APPROVED.pdf 1 DOC 11/23/2022 LEILANI ROJAS LR Inspection Notes 11- 23-22 FSS2022-0320.pdf LR Inspection Notes 11- 23-22 FSS2022-0320.pdf 1 DOC 11/23/2022 LEILANI ROJAS LR Inspection Notes 11- 23-22 FSS2022-0320.pdf LR Inspection Notes 11- 23-22 FSS2022- 0320_1.pdf 0 DOC 9/21/2022 REBECCA WINSCOTT LQ FSS2022-0307 and 0320 DUPLEX (COA).pdf LQ FSS2022-0307 and 0320 DUPLEX (COA).pdf 1 DOC 9/21/2022 REBECCA WINSCOTT LQ FSS2022-0307 and 0320 Rancho La Quinta DUPLEX.pdf LQ FSS2022-0307 and 0320 Rancho La Quinta DUPLEX.pdf 1 Printed: Wednesday, September 27, 2023 10:02:57 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0320 Fire Department Notes A. The installation of new fire sprinkler systems or modifications to existing systems shall comply with the following: NFPA 13D 2016 CBC 2019 CFC 2019 Local Municipal Codes Requirements of the AHJ All Manufacture Installation Guidelines Note: When conflict arrises between existing codes and standards, the most stringent shall apply. B. The Fire Department Shall require the following inspections and tests. 1. Overhead installation and hydrostatic test, ( prior to cover ). a. Normal opperating pressure when no FDC is installed. b. 200psi when FDC is required. c. Two hour minimum. 2. Final sprinkler and underground, ( prior to building final ). a. All inspections shall be scheduled by the contractor of record. b. Inspections shall be scheduled 24 hours in advance. GENERAL NOTES 1.General: All materials and devices shall conform to 2016 NFPA 13D standards. Installation shall conform to all applcable State and Local Codes. 2.Scope of Work: Install a new Residential Fire Protection System. 3.Piping: All overhead pipe and fittings shall be CPVC unless otherwise noted. 4.Design: NFPA 13D 2016 Edition and CFC Chapter 80 Standards. 5.System Demand @ Source. Two Sprinklers Flowing (16X16 Spacing): 31.3842 gpm @ 31.96psi ( 512 Max ) 6.Water Supply Data: Water is supplied from public water main in street. Static Pressure: 92.7 Information Source: CVWD 7.Sprinkler Head Spacing and Installation Requirements:Sprinklers shall not be located Closer than 8'-0" apart where there is no intervening obstruction. Sprinklers near potential obstruction shall be located per manufactures instructions. 8.Piping Supports: Piping shall be supported and restrained in conformance with local plumbing codes and CPVC manufactures instructions . Eachpipe section that supplies a drop to a sprinkler shall be secured no more than 12" from the drop to prevent laterial and vertical movement. 9.Pipe lenghts are approximate for hydraulic calculation and plan review purposes only. 10.The owner shall furnish sufficant heat in all areas to prevent freezingof pipe. 11.Waterflow Switch and Alarm: By Others a. A dedicated electrical circuit with a circuit breaker lock shall be provided for waterflow horn/strobes. b. An approved audible sprinkler waterflow alarm shall be visible from the street. The device shall be listed for outdoor use. An approved sign shall be placed at or near the device stating, SPRINKLER FIRE ALARM - WHEN ALARM SOUNDS CALL 911 c. An approved audible sprinkler waterflow alarm module shall be conected to the smoke detectors to alert occupants shall be provided. NFPA 13D REFERANCE NOTES 1. NFPA 13D, Section 8.3.2 Sprinklers shall not be required in bathrooms of 55 sq. ft. and less. 2. NFPA 13D, Section 8.3.3 Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions. (1) The area of the space does not exceed 24 sq. ft. (2) The walls and ceilings are surfaced with noncombustible or limited-combustible material as defined in NFPA 220. 3.NFPA 13D Section 8.3.4 Sprinklers shall not be required in garages, open attached porches, carports, and similar structures. Note that CFC 2016 Chapter 80 Referance Standards requires attached garages, attached porches, carports, and similar structures shall be sprinklered if there is occupied living space above. 4. NFPA 13D Section 8.2.5.6 Shadow Areas Shadow areas shall be permitted in the protection area of a sprinkler as long as the cumulative dry areas do not exceed 15 sq. ft. (1.4 sq. m.) per sprinkler. simon@silveradofire.com Scale Project number Date Drawn by Checked by Silverado Fire ProtectionPO Box 11474Palm Desert, Ca.92255760-574-6512C-16 # 1068664 As indicated 8/6/2022 8:38:50 AMFP-1 Site Plan Project Number 08-08-22 JA SC No. Description Date RANCHO LA QUINTAA Duplex Unit48220 and 48230 Via Vallarta,Rancho La Quinta CC,La Quinta, Ca. 92253 INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" www.cadmando.co.uk These blocks were brought to you by CADB locksFree.com.For all of your 2D & 3D CA D outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) M A T E R I A L L E G E N D Scale: 1/4"=1'-0" REFLECTED CEILING PLAN w w w w w w w Fire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1-1/4"Underground By Others Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) - --- Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 92.70 psi 82.30 psi 2800 GPM 0 GPM Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 Max SqFt 31.3842 GPM 53.9606 Psi 5 GPM 0 GPM WM 3 4 SOR BORTOR DOM 1 5 2 1" WATER METER WITH 15psi SHOWN AS Worst Case Friction Loss Supply Point Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-3 R-3 2 Gpm/SqFt 512 Max SqFt 31.3573 GPM 52.3503 Psi 5 GPM 0 GPM 6 10 7 WM2 8 9 SOR2 BOR2 TOR2 DOM2 Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-4 1 Gpm/SqFt 400 Max SqFt 25.0242 GPM 47.0535 Psi 5 GPM 0 GPM 11 Calc-3 Calc-4 Calc-1 NOTIFICATION DEVICE BY OTHERS 1" RISER 1-1/4" PVC UNDERGROUND BY OTHERS1-1/4" PVC UNDERGROUND BY OTHERS1" RISER 1 1/4"29' -0"1 1/4" 6' -1"1" x 9' -9"1" x 4' -3"1" 3' -5" 1" 12' -8" 1" 9' -1" 1" 9' -1" 1" 2' -8" 1" 14' -2"1"3' -2"1"13' -0"1"10' -11"1" 2' -0" 1" 2' -0" 1" 10' -0" 1" 1' -6" 1" 1' -7" 1" 12' -0" 1" 10' -0"1"8' -6"1"5' -9"1" 6' -10" 1" 2' -8"1"8' -6"1" 3' -6" 1" 12' -0" 1" 12' -0" 1" 12' -0" 1" 3' -10"1"4' -5"1"6' -3"1"4' -10"1" 2' -2"1"5' -7"1" 3' -4" 1" 8' -4" 1" 3' -1" 1" 12' -0" 1" 2' -3" 1" 5' -8" 1" 1' -0" 1" 2' -6" 1" 2' -5" 1" 7' -10" 1" 7' -10" 1" 3' -6" 1 1/4" 5' -0"1 1/4"6' -1"1 1/4"41' -5"1" x 9' -3"1" x 4' -9"1" 6' -9" 1" 2' -11" 1" 7' -3" 1" 11' -0" 1" 11' -0" 1" 3' -10" 1" 7' -2" 1" 5' -5" 1" 0' -10" 1" 2' -7" 1" 2' -4" 1" 5' -5" 1" 3' -5"1"9' -1"1"7' -7"1"3' -5"1" 6' -3" 1" 1' -6" 1" 3' -4"1"7' -7"1"8' -11"1"6' -6"1" 8' -6" 1" 6' -11" 1" 6' -0" 1" 6' -0" 1" 2' -5"1"6' -5"1"6' -7"1" 6' -0" 1" 6' -0" 1" 5' -7" 1" 3' -8" 1" 7' -9" 1" 5' -11" 1" 3' -10" 1" 1' -3"1"4' -7"INSPECTORS TEST INSPECTORS TEST PATIO PATIO GREAT ROOM 14'-0" GREAT ROOM 14'-0" KITCHEN 14'-0" KITCHEN 14'-0" ENTRY ENTRY MASTER 10'-0" MASTER 10'-0" M BATH 10'-0" M BATH 10'-0" POW 10'-0" POW 10'-0" BED 2 10'-0" BED 2 10'-0" BATH BATH LAUNDRY LAUNDRY HALL HALL HALL HALL GARAGE 10'-0" GARAGE 10'-0" 1" WATER METER WITH 15psi SHOWN AS Worst Case Friction Loss simon@silveradofire.com Scale Project number Date Drawn by Checked by Silverado Fire ProtectionPO Box 11474Palm Desert, Ca.92255760-574-6512C-16 # 1068664 As indicated 8/11/2022 8:08:20 AMFP-2 Piping Plan Project Number 08-08-22 JA SC No. Description Date RANCHO LA QUINTAA Duplex Unit48220 and 48230 Via Vallarta,Rancho La Quinta CC,La Quinta, Ca. 92253Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 39 Viking 1/2 Light Concealed Temperature - 155 Finish - B Quick Response Model - Mirage SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 155 °F 8 Viking 1/2 Light Pendent Temperature - 175 Finish - C Special Response Model - Micromatic SIN - VK494 K Factor - 4.9 VK494 4.9 1/2" 175 °F : 47 Total No. of Sprinklers: 47 Silverado Fire Protection PO Box 11474 Palm Desert, Ca. 92255 760-574-6512 Job Name : Duplex La Quinta Drawing : Location : Via Vallarta Remote Area : Calc-1 Contract : Data File : Duplex La Quinta Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire ProtectionPage 1 Duplex La QuintaDate 10203040E50R60U70S80S90E100R110P120130140150300 600 900 1200 1500 1800 2100 2400 2700FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 92.7 C2 - Residual Pressure: 82.3 C2 - Residual Flow : 2800 D1 - Elevation : 7.445 D2 - System Flow : 31.384 D2 - System Pressure : 53.961 Hose ( Demand ) : _______D3 - System Demand : 31.384 Safety Margin : 38.737 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire ProtectionPage 2 Duplex La QuintaDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire Protection Page 3 Duplex La Quinta Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 92.7 82.3 2800.0 92.697 31.38 53.961 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 14.19 4.9 7.04 13.0 0.05 256 2 15.0 7.3 TOR 11.0 26.85 DOM 1.22 33.1 5.0 BOR -3.0 36.69 3 -3.0 38.82 WM -3.0 53.88 4 -3.0 53.94 SOR -3.0 53.96 5 14.19 4.9 7.46 13.38 0.05 256 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Silverado Fire Protection Page 4 Duplex La Quinta Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 14.19 4.90 13.00 1 N 7.0 12.810 150 7.040 to 7.000 -0.351 2 15 13.0 1.101 19.810 0.0307 0.608 Vel = 4.38 2 15 13.38 1 9R 9.0 98.860 150 7.297 to 2N 14.0 58.000 1.732 TOR 11 26.38 1.101 7O 35.0 156.860 0.1136 17.818 Vel = 8.89 TOR 11 0.0 1 R 1.0 9.780 150 26.847 to N 7.0 8.000 4.236 DOM 1.22 26.38 1.101 17.780 0.1136 2.020 Vel = 8.89 DOM 1.22 + 5.00 5.00 1 N 7.0 4.220 150 33.103 to 7.000 1.828 BOR -3 31.38 1.101 11.220 0.1565 1.756 Vel = 10.57 BOR -3 0.0 1.25 N 8.0 34.920 150 36.687 to 8.000 0.0 3 -3 31.38 1.394 42.920 0.0497 2.131 Vel = 6.60 3 -3 0.0 1 0.400 150 38.818 to 15.000 * * Fixed Loss = 15 WM -3 31.38 1.101 0.400 0.1550 0.062 Vel = 10.57 WM -3 0.0 1 0.400 150 53.880 to 0.0 4 -3 31.38 1.101 0.400 0.1575 0.063 Vel = 10.57 4 -3 0.0 1.25 0.360 150 53.943 to 0.0 SOR -3 31.38 1.394 0.360 0.0500 0.018 Vel = 6.60 0.0 SOR 31.38 53.961 K Factor = 4.27 5 14.19 4.90 13.38 1 O 5.0 0.810 150 7.460 to 5.000 -0.351 2 15 13.38 1.101 5.810 0.0324 0.188 Vel = 4.51 0.0 2 13.38 7.297 K Factor = 4.95 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros 31401 Reserve Drive Suite 2 Route 111 Thousand Palms, Ca.92276 760-343-2233 Job Name : Duplex La Quinta Drawing : Location : Via Vallarta Remote Area : Calc-4 Contract : Data File : Duplex La Quinta Area Calc-4.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 1 Duplex La QuintaDate 10203040E50R60U70S80S90E100R110P120130140150300 600 900 1200 1500 1800 2100 2400 2700FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 92.7 C2 - Residual Pressure: 82.3 C2 - Residual Flow : 2800 D1 - Elevation : 5.713 D2 - System Flow : 25.024 D2 - System Pressure : 47.054 Hose ( Demand ) : _______D3 - System Demand : 25.024 Safety Margin : 45.645 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 2 Duplex La QuintaDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 3 Duplex La Quinta Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR2 92.7 82.3 2800.0 92.698 25.02 47.054 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 11 10.19 4.9 16.7 20.02 0.05 256 TOR2 11.0 21.56 DOM2 1.72 26.75 5.0 BOR2 -3.0 30.01 8 -3.0 31.78 WM2 -3.0 46.82 9 -3.0 46.86 SOR2 -3.0 47.05 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 4 Duplex La Quinta Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 11 10.19 4.90 20.02 1 N 7.0 45.370 150 16.700 to 4O 20.0 31.000 -0.351 TOR2 11 20.02 1.101 4R 4.0 76.370 0.0682 5.208 Vel = 6.75 TOR2 11 0.0 1 R 1.0 9.280 150 21.557 to N 7.0 8.000 4.019 DOM2 1.72 20.02 1.101 17.280 0.0682 1.179 Vel = 6.75 DOM2 1.72 + 5.00 5.00 1 N 7.0 4.720 150 26.755 to 7.000 2.044 BOR2 -3 25.02 1.101 11.720 0.1030 1.207 Vel = 8.43 BOR2 -3 0.0 1.25 N 8.0 46.250 150 30.006 to 8.000 0.0 8 -3 25.02 1.394 54.250 0.0326 1.771 Vel = 5.26 8 -3 0.0 1 0.400 150 31.777 to 15.000 * * Fixed Loss = 15 WM2 -3 25.02 1.101 0.400 0.1025 0.041 Vel = 8.43 WM2 -3 0.0 1 0.400 150 46.818 to 0.0 9 -3 25.02 1.101 0.400 0.1025 0.041 Vel = 8.43 9 -3 0.0 1.25 5.950 150 46.859 to 0.0 SOR2 -3 25.02 1.394 5.950 0.0328 0.195 Vel = 5.26 0.0 SOR2 25.02 47.054 K Factor = 3.65 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros 31401 Reserve Drive Suite 2 Route 111 Thousand Palms, Ca.92276 760-343-2233 Job Name : Duplex La Quinta Drawing : Location : Via Vallarta Remote Area : Calc-3 Contract : Data File : Duplex La Quinta Area Calc-3.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 1 Duplex La QuintaDate 10203040E50R60U70S80S90E100R110P120130140150300 600 900 1200 1500 1800 2100 2400 2700FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 92.7 C2 - Residual Pressure: 82.3 C2 - Residual Flow : 2800 D1 - Elevation : 7.445 D2 - System Flow : 31.357 D2 - System Pressure : 52.350 Hose ( Demand ) : _______D3 - System Demand : 31.357 Safety Margin : 40.347 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 2 Duplex La QuintaDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 3 Duplex La Quinta Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR2 92.7 82.3 2800.0 92.697 31.36 52.35 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 6 14.19 4.9 7.04 13.0 0.05 256 7 15.0 7.27 TOR2 11.0 24.39 DOM2 1.72 30.37 5.0 BOR2 -3.0 34.24 8 -3.0 36.93 WM2 -3.0 51.99 9 -3.0 52.06 SOR2 -3.0 52.35 10 14.19 4.9 7.43 13.36 0.05 256 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 4 Duplex La Quinta Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 6 14.19 4.90 13.00 1 N 7.0 11.810 150 7.040 to 7.000 -0.351 7 15 13.0 1.101 18.810 0.0307 0.577 Vel = 4.38 7 15 13.36 1 N 7.0 89.730 150 7.266 to 9R 9.0 46.000 1.732 TOR2 11 26.36 1.101 6O 30.0 135.730 0.1134 15.389 Vel = 8.88 TOR2 11 0.0 1 R 1.0 9.280 150 24.387 to N 7.0 8.000 4.019 DOM2 1.72 26.36 1.101 17.280 0.1134 1.960 Vel = 8.88 DOM2 1.72 + 5.00 5.00 1 N 7.0 4.720 150 30.366 to 7.000 2.044 BOR2 -3 31.36 1.101 11.720 0.1563 1.832 Vel = 10.57 BOR2 -3 0.0 1.25 N 8.0 46.250 150 34.242 to 8.000 0.0 8 -3 31.36 1.394 54.250 0.0495 2.688 Vel = 6.59 8 -3 0.0 1 0.400 150 36.930 to 15.000 * * Fixed Loss = 15 WM2 -3 31.36 1.101 0.400 0.1575 0.063 Vel = 10.57 WM2 -3 0.0 1 0.400 150 51.993 to 0.0 9 -3 31.36 1.101 0.400 0.1575 0.063 Vel = 10.57 9 -3 0.0 1.25 5.950 150 52.056 to 0.0 SOR2 -3 31.36 1.394 5.950 0.0494 0.294 Vel = 6.59 0.0 SOR2 31.36 52.350 K Factor = 4.33 10 14.19 4.90 13.36 1 O 5.0 0.810 150 7.430 to 5.000 -0.351 7 15 13.36 1.101 5.810 0.0322 0.187 Vel = 4.50 0.0 7 13.36 7.266 K Factor = 4.96 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16”) Base Part No. 21876 (2-3/4” diameter) or Base Part No. 21875 (3-5/16” diameter). Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Refer to Table 1. (Also refer to the Viking website.) A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres - sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. 1 2 3 4 4 4 Ordinary 155 °F (68 °C)100 °F (38 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Red Intermediate 200 °F (93 °C)150 °F (65 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Green Brass and ENT 6: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 5: ENT 1.The sprinkler temperature rating is stamped on the deflector. 2.Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3.Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4.Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5.The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6.Stainless Steel versions are not available with any finishes or paint. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 1 SIN - U.S.2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) 6 GPM (LPM)3,5 155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 8. See Footnotes 7,9, 10, & 11 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) 1.Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2.Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3.This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4.Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5.Meets New York City requirements, effective July 1, 2008. 6.For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7.Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). 8.Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. 10.C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) 11.Stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) : When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover - age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: •The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, •Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. •Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: - • • Step 1: Step 2: FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 NOTE: to approximately 13/16” (21 mm) below the sprinkler body. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org September 21, 2022 Silverado Fire Protection Re: Residential Fire Sprinkler Plan Review – Rancho La Quinta DUPLEX 48220 & 48230 Via Vallarta The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Rebecca Winscott - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 48220 & 48230 Via Vallarta PERMIT#: FSS2022-0307 / 0320 DATE ISSUED: 9-21-22 DESCRIPTION: Rancho La Quinta DUPLEX CONTRACTOR: Silverado Fire Protection HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.