Loading...
FSS2022-0353ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (800)915-3473 jamieb@fireinc.net CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (800)915-3473 jamieb@fireinc.net OWNER Woodbridge Pacific 27285 Las Ramblas Mission Viejo CA 92691 (800)915-3473 jamieb@fireinc.net CONDITIONS Description: SIGNATURE / FIRE SPRINKLER PLAN / BRES2022-0470 / PLAN 8B Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - TRACT HOMES Status: FINALED Applied: 10/7/2022 ECON Parcel No: 775220021 Site Address: 80132 CHAMPIONS WY LA QUINTA,CA 92253 Approved: 10/11/2022 JLIM Subdivision: PM 20426 Block: Lot: 9 Issued: 10/12/2022 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/11/2023 LRO Valuation: $1,540.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, April 19, 2023 4:41:35 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0353 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 12/5/2022 12/5/2022 NOT READY No fee OVERHEAD HYRO KHET 12/5/2022 12/5/2022 NOT READY No fee OVERHEAD HYRO LRO 1/11/2023 1/11/2023 APPROVED OVERHEAD ROUGH PIPING LRO 1/11/2023 1/11/2023 APPROVED FIRE FINAL**LRO 4/11/2023 4/11/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) JACK LIMA 10/7/2022 10/10/2022 10/11/2022 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 10/12/22 WEB13308 739503439 CREDIT 684600 ECON Total Paid for FIRE FEES: $167.00 $167.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 10/12/22 WEB13308 739503439 CREDIT 684600 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 10/12/22 WEB13308 739503439 CREDIT 684600 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$186.00 $186.00 Printed: Wednesday, April 19, 2023 4:41:35 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0353 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/7/2022 Etrakit Contractor Application Lot 9 Plan 8 Application.pdf 1 DOC 10/7/2022 Etrakit Contractor Tracking Sheet Lot 9 Plan 8 Building Tracking Sheet.pdf 1 DOC 1/11/2023 LEILANI ROJAS FSS2022-0353 Insp Notes LMR 1-11-23.pdf FSS2022-0353 Insp Notes LMR 1-11-23.pdf 1 BOND INFORMATION Printed: Wednesday, April 19, 2023 4:41:35 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0353 *FOR REFERENCE ONLYELEV.-2'FINISH GRADEELEV.-2'0' ELEV.2'¾"METERMETERPSI LOSSELEV.-2'MAINCITYELEV.5421TO DOMESTIC WATERCONTROL VALVE FOR DOMESTIC5 GPM ALLOWANCE7PVCMAX1½"70'COPPER K MAX1"30PRESSURE REGULATORTO BE SET AT 60 PSICOPPER L1½"OCCUPANCY:CONSTRUCTION:STORIES:FIRE SPRINKLER SYSTEM:DESIGNED AND INSTALLED PER 2016 NFPA 13D ALLRESIDENTIAL WITH A .05 DENSITY WITHIN AREAS.2V-B R3 / U CONCEALED RES. PENDENT SPRINKLERRISER LOCATION (PER DETAIL)NODE POINT FOR CALCULATIONRES. PENDENT SPRINKLERCHANGE IN ELEVATIONXXBUILDING AREA: 3,063 SQFT.APPROVAL STAMPSIGNATURE @ PGA WESTPLAN 8TRACT #36537LA QUINTA, CA.AHJ: LA QUINTA FIRE DEPARTMENTGENERAL NOTESLICENSE NO. 684600705 E. HARRISON ST., SUITE 200CORONA, CA 92879PH - 800-915-3473FAX - 951-272-2535CUSTOM, TRACT, MULTI-FAMILYAND COMMERCIALDESIGN, X.X.INEERING ANDINSTALLATIONN.T.S.IF SHEET IS LESS THANSHEET FP1 OF FP4SIZE - 24" X 36"SHEET ID24" X 36" IT IS A REDUCEDSCALEPRINT SCALEREDUCE ACCORDINGLYNO. DATE REVISION12345CLASSIFICATIONC-16LICENSE NO.684600FIREPROTECTIONCONTRACTORFSTATEOFCALIFORNIAThe recipient of these planshereby acknowledges that allplans, details, specifications ormethods of installationcontained in this set of plans isthe sole property of FireSprinkler Systems, Inc. andthat any use of this set of plansis prohibited and is a violationof copyright laws without firstreceiving permission from FireSprinkler Systems.DRAWN BY:320341/4/21JOB NO:DATE:C.P.WOODBRIDGE PACIFICSIGNATURE @ PGA WESTBY:LA QUINTA, CAPLAN 8GENERAL NOTES AND LEGEND13D GENERAL NOTES12.11.10.9.8.7.6.5.4.3.2.1.AUTOMATIC FIRE SPRINKLER SYSTEM HAS BEEN DESIGNED TO BEINSTALLED IN ACCORDANCE WITH NFPA 13D, 2016 EDITION AND THEREQUIREMENTS OF THE CITY OF LA QUINTA FIRE DEPARTMENT.THIS SPRINKLER SYSTEM SHALL BE TESTED AND INSPECTED BOTHTHE ROUGH AND FINAL INSPECTION PRIOR TO OCCUPANCY BEINGGRANTED. THE JURISDICTIONAL FIRE PREVENTION OFFICE WILL BE NOTIFIED A MINIMUM OF TWO WORKING DAYS IN ADVANCE OF THE REQUESTED INSPECTION.THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS,NOTCHING, DRILLING, OR OTHERWISE PENETRATING STRUCTURALMEMBERS SHALL BE IN ACCORDANCE WITH CALIFORNIA BUILDING CODE.TYPE OF PLASTIC PIPE TO BE CPVC MANUFACTURED BY BLAZEMASTERU.L. LISTED.ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN INDICATINGIT'S FUNCTION.PIPE SHALL BE HUNG FROM STRUCTURAL MEMBER PER THE UNIFORMPLUMBING CODE. PIPE CLAMPS AND SCREWS ARE MANUFACTURED BYAFCON MFG. ARE U.L. LISTED AND ARE INSTALLED ACCORDING TO THEHANGING REQUIREMENTS IN THEIR TECHNICAL DATA (SEE DETAIL).THE SPACING AND LOCATION OF SPRINKLERS SHALL CONFORM WITHTHE MANUFACTURES REQUIREMENTS AND THOSE CONTAINED IN NFPA 13D, 2016 EDITION.IF REQUIRED BY A.H.J. THE ALARM INDICATING DEVICE SHALL BE LISTEDFOR OUTSIDE SERVICE AND AUDIBLE FROM THE ADDRESS THAT THE HOUSE IS ADDRESSED ON. SMOKE DETECTORS TO BE INSTALLED BY OTHERS.RESIDENTIAL CONCEALED PENDENT SPRINKLERS ARE U.L. LISTED ANDMANUFACTURED BY SENJU. INSTALLED AT 14 FT. MAXIMUM SPACING(SEE TECH. DATA).PENDENT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS ARE U.L. LISTED AND MANUFACTURED BY VIKING INSTALLED AT 14 FT. MAX. SPACING(SEE TECH. DATA).13. PENDENT SPRINKLERS ARE AT LEAST 3 ft. FROM OBSTRUCTIONS E.G. LIGHTFIXTURES, CEILING FANS, ETC. OR IN ACCORDANCE WITH TABLE 8.2.5.4.2 ANDSECTION 8.2.5.1. SPRINKLER LOCATIONS FOR CONTINUOUS OBSTRUCTIONSARE IN COMPLIANCE WITH 8.2.5.4.14. SOFFITS AND CABINETS TO BE PROVIDED WITH SPRINKLER COVERAGE INACCORDANCE WITH 8.2.5.5.UNDERGROUND DETAILN.T.S. (FOR REFERENCE ONLY)RISER DETAILN.T.S.HYDRAULIC NAMEPLATEN.T.S.VICINITY MAPN.T.S.LEGAL DESCRIPTIONHANGER TIC DETAILBUILDING SUMMARYSYMBOL LEGENDHYDRAULIC SYSTEMThis Building is Protected by aHydraulically DesignedAutomatic Sprinkler System.Date InstalledLocationNumber of SprinklersBasis of Design1. DENSITY2. DESIGNED AREA OF DISCHARGESystem Demand1. WATER FLOW RATE2. RESIDUAL PRESSURE AT THE BASE OF THE RISERInstalled By Fire Sprinkler Systems, Inc.1/4/21CALC AREA 12.05 gpm/sq.ft.392 sq.ft.25.2 gpm32.7 psiRESIDUALSTATIC66.8 - 10% = 60.1 PSI72.9 - 10% = 65.6 PSIWATER FLOW INFORMATIONFLOW1,500 GPMMAIN DRAIN VALVEDRAIN TO EXTERIORRUBBER FACED CHECK VALVEELEV.GAUGE1/2"CPVC TO SYSTEM11'CPVC RISER1"10ALL WORK FOR FIRE SPRINKLERSYSTEMS, INC. TO BEGIN AT B.O.R.14-1/2" x 14-1/2"ACCESS DOOR1" CPVC52.5 PSI LOSS15. SPARE SPRINKLERS SHALL NOT BE REQUIRED TO BE PROVIDED IN ACCORDANCE WITH 5.1.1.2NOT BE REQUIRED TOSPARE SPRINKLERS SHALLPROVIDEDPER 5.1.1.23MASTER PLAN SUBMITTAL67ELEV.4'ELEV.2'STATIC PRESSURE = 79.8 PSIPSI LOSS - 6.972.9 PSIPSI LOSS = 6.9x .43416'HIGHEST PAD ELEV. @ 503'TEST HYDRANT ELEV. @ 487'ELEV. DIFFERENCE = RES. PRESSURE = 73.7 PSIPSI LOSS - 6.966.8 PSIVICINITY MAPCONCEALED RES. PENDENT SPRINKLERMASTER PLAN SUBMITTAL16.NFPA13D 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING UNIT, NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. TRACT #365376/18/21AS-BUILT PER INSPECTOR (C.H.)APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST06/30/2021 1:04:57 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FCMP2021-0008REVISED PLANSKohl HetrickReason: I am approving this documentContact Info: 760-219-6057Date: 2021.06.30 13:06:36-07'00' LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, X.X.INEERING AND INSTALLATION 1/4" = 1' IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems. FIRE SPRINKLER PLAN SHEET FP2 OF FP4 DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2016 ED. TOTAL LIVING AREA - GARAGE AREA- 2nd FLOOR AREA - 1st FLOOR AREA - 2,017 SQ. FT. 513 SQ. FT. 2,530 SQ. FT. 533 SQ. FT.NO.DATEREVISION12345TV C6 TV C6 SD D W CM SD SD TV C6 JSCALE: 1/4" = 1'-0" PLAN 8 - 1ST FLOOR SPRINKLER PLAN HEAT ZONE COVERED OUTDOOR DINING ROOM VOLUME CLG. LIVING ROOM VOLUME CLG. MASTER BEDROOM 10'-0" CLG. 19 SQFT. MASTER BATH 10'-0" CLG. W.I.C. 9'-0" CLG. LAUNDRY 9'-0" CLG. BATH 2 9'-0" CLG. PANTRY 10'-0" CLG. GARAGE 10'-0" CLG. KITCHEN 10'-0" CLG. CAB. 8 SQFT. CAB. POWDER 10'-0" CLG. 44 SQFT. BEDROOM 2 10'-0" CLG. 16 SQFT. PORCH GOLF CART GARAGE 10'-0" CLG. 30 SQFT.UP ¾" x 10'-0"HEAT ZONE RISER LOCATION 10 3'-7"5'-2"3'10'-1"3'-6"4'-7"3'-8"2'-5"3'-2"5'5'-11"2'-3"6'-5"7'-10"4'-8" 2'-10"3'-7"3'-3"4'-11"7'11"6'-3"1'-7"9"3'6'-5"3'-7"3'-1"9"9'-3"10"3'-6" 13'-10"1'5'-6"1'4'-10" 4'-3" 18'9"2'2'-11" 3'9"1'-1"3'-7"4'-5"4'-5"3'-3" 3'-1"5'5'5'5'5'-5"13'-8"8'-2"8'-1" 6'-7"1'-11"9'-6"6' 7'4'-1"5'-10"5'-8"4'-10"8'-7"6'-5"6'-6" 3'8'8'5'4'UP ¾" x 10'-0"UP ¾" x 10'-0"UP ¾" x 10'-0"20'x20' SPACING 20'x20' SPACING LINE OF FLOOR ABOVE LINE OF FLOOR ABOVE OPEN TO ABOVE LINE OF FLOOR ABOVE *1½" STRUCT. PENETRATION* 1112 13 SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - CARBON STEEL. FINISH - Mil. Galvanized. LISTING/APPROVAL - 203-EX 4231, EX 2551 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC PIPE - #905 screw - no pre-drill. 3/4" - 3" Steel and Copper pipe - #14 x 1 1/2" SMS or 1/4"x1 1/2" lag bolt - no pre-drill. in STEEL: min. 18 GA. 3/4" - 3" CPVC, Copper and Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap StabilizeHanger Restraint 2.126 2.312 3.170 3.400 4.320 5.3203 2 1/2 1 1/2 1 1/4 1 3/4 510 SIZE FAST. DIM. AFCON 510 HANGER (STEEL - COPPER - C.P.V.C.) NOT TO SCALE Nominal Pipe Size (in.) ¾"1"1¼"1½"2"2½"3"3½"4"5"6"8" N/A 12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 12'-0"N/A 15'-0" 12'-0"12'-0"12'-0"12'-0"12'-0"N/A N/A N/A N/A N/A 8'-0"8'-0"10'-0"10'-0"12'-0"12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 5'-6"6'-0"6'-6"7'-0"8'-0"9'-0"10'-0"N/A N/A N/A N/A N/A N/A 3'-9"4'-7"5'-0"5'-11"N/A N/A N/A N/A N/A N/A N/A 2'-11"3'-4"3'-11"4'-5"5'-5"N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'-0"N/A N/A 15'-0"N/A 15'-0"15'-0" Steel pipe except threaded lightwall Threaded lightwall steel pipe Copper tube CPVC Polybutylene (IPS) Polybutylene (CTS) Ductile iron pipe 1.50 #905 #906 AFCON 514 HANGER (STEEL - COPPER - C.P.V.C.) NOT TO SCALE Restraint Restraint Nominal Pipe Size (in.) ¾"1"1¼"1½"2"2½"3"3½"4"5"6"8" N/A 12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 12'-0"N/A 15'-0" 12'-0"12'-0"12'-0"12'-0"12'-0"N/A N/A N/A N/A N/A 8'-0"8'-0"10'-0"10'-0"12'-0"12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 5'-6"6'-0"6'-6"7'-0"8'-0"9'-0"10'-0"N/A N/A N/A N/A N/A N/A 3'-9"4'-7"5'-0"5'-11"N/A N/A N/A N/A N/A N/A N/A 2'-11"3'-4"3'-11"4'-5"5'-5"N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'-0"N/A N/A 15'-0"N/A 15'-0"15'-0" Steel pipe except threaded lightwall Threaded lightwall steel pipe Copper tube CPVC Polybutylene (IPS) Polybutylene (CTS) Ductile iron pipe SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Glavanized. LISTING/APPROVAL - INSTALLATION - Per these instructions PATENT - No. 6,648,278. 203-EX 4231, EX 2551 Stabilize vertical piping. Install on horizontal or vertical mounting surface. FUNCTION - Support horizontal piping: CPVC, Copper or Steel. WOOD - CPVC pipe - #905 screw- no pre-drill. Provides listed vertical/horizontal restraint and prevents Thru 5/8" gypsum board - 1/4"x 2" lag screw. upward movement of pipe from pendent sprinkler discharge. When #905 threads are exposed in wood, install #906 backing nut. including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Snap over pipe then squeeze strap back allowing pipe to slide freely. STEEL - min. 18 GA. - CPVC, Copper and Stell pipe - 1/4" or #14 Tek Screw. FASTENERS - UL Listed per NFPA 13 CONCRETE: Required minimum load each fasterner = 5(wt)+250lbs. Copper and Steel pipe - #14 SMS or 1/4 "x1 1/2" lag screw - no pre-drill. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * Common center-line for 3/4" and 1". * Offset edge eliminates abrasion. * AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. AFCON #906 backing nut sold serparately. 3.00 Stabilize Hanger/Restrainer DRAWN BY: 32034 1/4/21 JOB NO: DATE: C.P.WOODBRIDGE PACIFICSIGNATURE @ PGA WESTBY:LA QUINTA, CAPLAN 8MASTER PLAN SUBMITTALTRACT #36537SENJUVIKING3.73.0205°175°14'x14'14'x14'SPACINGTEMP.K-FAC.SYMBOLMODELMANUF.SIN #SS8261VK470FREEDOMPENDENT7/16"7/16"ORIFICERC-RESCONC. PEND.136QUANTITY2TOTAL SPRINKLERS IN THIS SHEET:21---------VIKING4.9200°20'x20'VK4947/16"FREEDOMCONC. PEND.NOTES: 1.ALL HEAD SPACING TO BE 14'x14', UNLESS OTHERWISE NOTED. 2.ALL PIPES TO BE ¾" CPVC, UNLESS OTHERWISE NOTED. 3.PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9.3.4. 4.HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5.ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH MIN. 6" INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE (2016 NFPA 13D 7.7). 6.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sqft. AND LESS. (SECTION 8.3.2.) 7.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS: (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sqft. (2) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. 8. 8.2.5.1.2 THE DISTANCE SHALL BE MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION. 9. 8.2.5.6 SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS THE CUMULATIVE DRY AREA DO NOT EXCEED 15sqft (1.4 sqm) PER SPRINKLER. U P ¾ " x 1 0 ' - 0 "UP ¾" x 10'-0"1 1 6/18/21AS-BUILT PER INSPECTOR (C.H.) J TV C6 SD TV C6 SD CM CM SD SCALE: 1/4" = 1'-0" PLAN 8 - 2ND FLOOR SPRINKLER PLAN LOFT 9'-0" CLG. ATTIC ACCESS BEDROOM 3 9'-0" CLG. BATH 3 9'-0" CLG. LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, X.X.INEERING AND INSTALLATION 1/4" = 1' IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems. FIRE SPRINKLER PLAN SHEET FP3 OF FP4 DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2016 ED.NO.DATEREVISION12345TOTAL LIVING AREA - GARAGE AREA- 2nd FLOOR AREA - 1st FLOOR AREA - 2,017 SQ. FT. 513 SQ. FT. 2,530 SQ. FT. 533 SQ. FT. HEAT ZONE 56 SQ. FT. 13 SQ. FT. 5'-3"10'-5"11'-9"7'-11"1'-10"2'-3"1'-7"4'-4"7'-2"4'-1"4'-10"8'-9"6" 2'-5"5'-3"8'-3"5'-3"8'-3"5'-3" 13'1'-7"2'-5"6" 13'-6"7'6'-4" 12'14'6'-7"7'3'-7"4'-6"6'-5"10'5'-7"1' - 2 "5'-4"DN ¾" x 10'-0"DN ¾" x 10'-0"DN ¾" x 10'-0"D N ¾ " x 1 0 ' - 0 " 20'x20' SPACING OPEN TO BELOW REQUIRED PER 8.2.5.6 (6 SQ. FT.) NO A/S REQUIRED PER 8.2.5.6 (2 SQ. FT.) NO A/S R.A.G. 14 15 2322 18 19 16 17 20 21 CALC AREA 2 CALC AREA 1 4' SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - CARBON STEEL. FINISH - Mil. Galvanized. LISTING/APPROVAL - 203-EX 4231, EX 2551 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC PIPE - #905 screw - no pre-drill. 3/4" - 3" Steel and Copper pipe - #14 x 1 1/2" SMS or 1/4"x1 1/2" lag bolt - no pre-drill. in STEEL: min. 18 GA. 3/4" - 3" CPVC, Copper and Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap StabilizeHanger Restraint 2.126 2.312 3.170 3.400 4.320 5.3203 2 1/2 1 1/2 1 1/4 1 3/4 510 SIZE FAST. DIM. AFCON 510 HANGER (STEEL - COPPER - C.P.V.C.) NOT TO SCALE Nominal Pipe Size (in.) ¾"1"1¼"1½"2"2½"3"3½"4"5"6"8" N/A 12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 12'-0"N/A 15'-0" 12'-0"12'-0"12'-0"12'-0"12'-0"N/A N/A N/A N/A N/A 8'-0"8'-0"10'-0"10'-0"12'-0"12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 5'-6"6'-0"6'-6"7'-0"8'-0"9'-0"10'-0"N/A N/A N/A N/A N/A N/A 3'-9"4'-7"5'-0"5'-11"N/A N/A N/A N/A N/A N/A N/A 2'-11"3'-4"3'-11"4'-5"5'-5"N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'-0"N/A N/A 15'-0"N/A 15'-0"15'-0" Steel pipe except threaded lightwall Threaded lightwall steel pipe Copper tube CPVC Polybutylene (IPS) Polybutylene (CTS) Ductile iron pipe 1.50 #905 #906 AFCON 514 HANGER (STEEL - COPPER - C.P.V.C.) NOT TO SCALE Restraint Restraint Nominal Pipe Size (in.) ¾"1"1¼"1½"2"2½"3"3½"4"5"6"8" N/A 12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 12'-0"N/A 15'-0" 12'-0"12'-0"12'-0"12'-0"12'-0"N/A N/A N/A N/A N/A 8'-0"8'-0"10'-0"10'-0"12'-0"12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 5'-6"6'-0"6'-6"7'-0"8'-0"9'-0"10'-0"N/A N/A N/A N/A N/A N/A 3'-9"4'-7"5'-0"5'-11"N/A N/A N/A N/A N/A N/A N/A 2'-11"3'-4"3'-11"4'-5"5'-5"N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'-0"N/A N/A 15'-0"N/A 15'-0"15'-0" Steel pipe except threaded lightwall Threaded lightwall steel pipe Copper tube CPVC Polybutylene (IPS) Polybutylene (CTS) Ductile iron pipe SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Glavanized. LISTING/APPROVAL - INSTALLATION - Per these instructions PATENT - No. 6,648,278. 203-EX 4231, EX 2551 Stabilize vertical piping. Install on horizontal or vertical mounting surface. FUNCTION - Support horizontal piping: CPVC, Copper or Steel. WOOD - CPVC pipe - #905 screw- no pre-drill. Provides listed vertical/horizontal restraint and prevents Thru 5/8" gypsum board - 1/4"x 2" lag screw. upward movement of pipe from pendent sprinkler discharge. When #905 threads are exposed in wood, install #906 backing nut. including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Snap over pipe then squeeze strap back allowing pipe to slide freely. STEEL - min. 18 GA. - CPVC, Copper and Stell pipe - 1/4" or #14 Tek Screw. FASTENERS - UL Listed per NFPA 13 CONCRETE: Required minimum load each fasterner = 5(wt)+250lbs. Copper and Steel pipe - #14 SMS or 1/4 "x1 1/2" lag screw - no pre-drill. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * Common center-line for 3/4" and 1". * Offset edge eliminates abrasion. * AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. AFCON #906 backing nut sold serparately. 3.00 Stabilize Hanger/Restrainer DRAWN BY: 32034 1/4/21 JOB NO: DATE: C.P.WOODBRIDGE PACIFICSIGNATURE @ PGA WESTBY:LA QUINTA, CAPLAN 8MASTER PLAN SUBMITTALTRACT #36537SENJUVIKING3.73.0205°175°14'x14'14'x14'SPACINGTEMP.K-FAC.SYMBOLMODELMANUF.SIN #SS8261VK470FREEDOMPENDENT7/16"7/16"ORIFICERC-RESCONC. PEND.7-QUANTITY1TOTAL SPRINKLERS IN THIS SHEET:8---------VIKING4.9200°20'x20'VK4947/16"FREEDOMCONC. PEND.NOTES: 1.ALL HEAD SPACING TO BE 14'x14', UNLESS OTHERWISE NOTED. 2.ALL PIPES TO BE ¾" CPVC, UNLESS OTHERWISE NOTED. 3.PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9.3.4. 4.HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5.ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH MIN. 6" INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE (2016 NFPA 13D 7.7). 6.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sqft. AND LESS. (SECTION 8.3.2.) 7.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS: (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sqft. (2) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. 8. 8.2.5.1.2 THE DISTANCE SHALL BE MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION. 9. 8.2.5.6 SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS THE CUMULATIVE DRY AREA DO NOT EXCEED 15sqft (1.4 sqm) PER SPRINKLER.DN ¾" x 10'-0"DN ¾" x 10'-0"3' 4'-6"3'-9"2'1 1 6/18/21AS-BUILT PER INSPECTOR (C.H.) LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, X.X.INEERING AND INSTALLATION AS SHOWN IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems.SECTIONS FOR REFERENCE ONLYSECTIONS SHEET FP4 OF FP4NO.DATEREVISION12345DRAWN BY: 32034 1/4/21 JOB NO: DATE: C.P.WOODBRIDGE PACIFICSIGNATURE @ PGA WESTBY:LA QUINTA, CAPLAN 8MASTER PLAN SUBMITTALTRACT #365376/18/21AS-BUILT PER INSPECTOR (C.H.)