FSS2022-0354
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM CONTRACTOR DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM OWNER DE WITTE CONSTRUCTION 77-775 JACKAL DRIVE #E La Quinta CA 92253 (760)322-0995 CONDITIONS Description: SMITH / FIRE SPRINKLER /BRES2021-0758 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: ISSUED Applied: 10/10/2022 ECON Parcel No: 770310012 Site Address: 78623 PEERLESS PLACE LA QUINTA,CA 92253 Approved: 11/2/2022 RWI Subdivision: TR 28470-1 Block: Lot: 35 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $22,000.00 Occupancy Type: Construction Type: Expired: 5/22/2023 KHET No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, April 19, 2023 4:43:09 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0354 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO KHET 11/23/2022 11/23/2022 APPROVED No leaks OVERHEAD ROUGH PIPING KHET 11/23/2022 11/23/2022 APPROVED AS-BUILT REQD PRIOR TO FINAL REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) REBECCA WINSCOTT 10/10/2022 10/24/2022 11/2/2022 APPROVED 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 10/10/2022 10/11/2022 10/11/2022 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $250.00 $250.00 11/10/22 WEB13582 751049246 CREDIT 563921 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 11/10/22 WEB13582 751049246 CREDIT 563921 ECON Total Paid for FIRE FEES: $500.00 $500.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/10/22 WEB13582 751049246 CREDIT 563921 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 11/10/22 WEB13582 751049246 CREDIT 563921 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$519.00 $519.00 Printed: Wednesday, April 19, 2023 4:43:09 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0354 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/10/2022 Etrakit Contractor 1ST SUBMITTAL - SITE PLAN smith-res-fire.pdf 1 DOC 10/10/2022 Etrakit Contractor 1ST SUBMITTAL - HYDRAULIC CALCULATIONS smith-res- rma12_calcs.pdf 1 DOC 10/10/2022 Etrakit Contractor SMITH CUT SHEETS Smith_Specs.pdf 1 DOC 10/10/2022 Etrakit Contractor CVWD STATIC WATER PRESSURE Static Pressure 770-310- 012 Lot 35 78-623 Peerless Place.pdf 1 DOC 11/23/2022 KOHL HETRICK FSS2022-0354 - 11-23- 2022 - Insp Notes.pdf FSS2022-0354 - 11-23- 2022 - Insp Notes.pdf 1 DOC 11/2/2022 REBECCA WINSCOTT LQ FSS2022-0354 Smith Residence Approved.pdf LQ FSS2022-0354 Smith Residence Approved.pdf 1 DOC 11/2/2022 REBECCA WINSCOTT LQ FSS2022-0354 Smith Residence COA.pdf LQ FSS2022-0354 Smith Residence COA.pdf 1 BOND INFORMATION Printed: Wednesday, April 19, 2023 4:43:09 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0354 FPFPFP+10' CEILING+11' CEILING+10' CEILING+9' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+9' CEILING+10' CEILINGSLOPESLOPESLOPESLOPE ARCH+10' CEILING+9' CEILING+9' CEILING+10' CEILING+9' CEILING+10' CEILING+12' CEILING+10' CEILING+9' CEILING+9' CEILING+10' CEILING+10' CEILING+11' CEILING+10' CEILING+12' CEILING+11' CEILING+12' CEILING+11' CEILING+9' CEILING+11' CEILING+12' CEILING+10'+10'+10'+10'+10'+11' CEILING+10' CEILING+10'+12' CEILINGHEATERHEATER HEATER12x1610x1210x1210x1210x1210x1210x1210x1210x1210x1210x128x108x108x108x10 8x108x108x108x108x108x1010x14 22"x30"ATTICACCESS22"x30"ATTICACCESS22"x30"ATTICACCESSOWNER SUITESS SWINEELECT.GOLF CARTENTRY COURTCASITATHEATERPOWDERENTRYFOYERMECH.OWNER'S BATHWICWCWCCOVERED LOGGIAPREPKITCHENPANTRYKITCHENWICWICWICHALLHALLLAUNDRYA/VBATH 2BEDROOM 2GREAT ROOMVANITYWHWHBBQPATIOHALLHALLBEDROOM 3REF.LINEN DESKPATIOGARAGEHALLVESTIBULEBATH 4PATIOBATH 3LINENCOATSDWDW DININGROOMSHOWERWW123H1011,2002001010011012028013025091053140061063064FIRE RISER LOCATIONMECHANICAL HEAT REGISTERTOTAL HEADS = 69FPFPFP+10' CEILING+11' CEILING+10' CEILING+9' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+9' CEILING+10' CEILINGSLOPESLOPESLOPE SLOPE ARCH+10' CEILING+9' CEILING+9' CEILING+10' CEILING+9' CEILING+10' CEILING+12' CEILING+10' CEILING+9' CEILING+9' CEILING+10' CEILING+10' CEILING+11' CEILING+10' CEILING+12' CEILING+11' CEILING+12' CEILING+11' CEILING+9' CEILING+11' CEILING+12' CEILING+10'+10'+10'+10'+10'+11' CEILING+10' CEILING+10'+12' CEILINGHEATER HEATER HEATER12x1610x12 10x12 10x12 10x12 10x12 10x12 10x12 10x12 10x12 10x12 8x108x108x108x108x108x108x108x108x108x1010x14 22"x30"ATTICACCESS22"x30"ATTICACCESS22"x30"ATTICACCESSOWNER SUITES S SWINEELECT.GOLF CARTENTRY COURTCASITATHEATERPOWDERENTRYFOYERMECH.OWNER'S BATHWICWCWCCOVERED LOGGIAPREPKITCHENPANTRYKITCHENWICWICWICHALLHALLLAUNDRYA/VBATH 2BEDROOM 2GREAT ROOMVANITYWHWHBBQPATIOHALLHALLBEDROOM 3REF.LINEN DESKPATIOGARAGEHALLVESTIBULEBATH 4PATIOBATH 3LINENCOATSDWDW DININGROOMSHOWERWWC-16 CALIFORNIA563921LICENSE NO.D E S ERT-FIREFIRE PROTECTION CONT R ACTOR ATTIC/FAU HEADS OPTIONAL - NOT REQUIREDAPPROVEDRwinscot11/02/2022 9:22:48 AMRiverside County Fire DepartmentOffice of the Fire MarshalBy:Rebecca WinscottDigitally signed by Rebecca WinscottDN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca WinscottDate: 2021.09.10 13:10:33-07'00'Fire Safety Specialist HEAT SOURCE MINIMUM DISTANCE FROM EDGE OF SOURCE IN INCHESSIDE OF OPEN OR RECESSED FIRE PLACE`36" 12"FRONT OF RECESSED FIREPLACE60" 36"COAL OR WOOD BURNING STOVE42"12"KITCHEN RANGE OR OVEN18"9"WALL OVBNS18"9"HOT AIR FLUES18"9"UNINSULATED HEAT DUCTS18"9"UNINSULATED WATER PIPES12"6"SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS24"12"FRONT OF WALL MOUNTED OR HOT AIR DIFFUSERS36"18"HOT WATER HEATER OR FURNACE6"3"LIGHT FIXTURES0W TO 250 W 6"3"250W TO 499 W 12"6"ORDINARY TEMP INTERM. TEMPThis system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat point of connection.Hose stream allowance ofis included in the above.1DINING ROOMDESERT FIRE9/27/22SMITH RESIDENCEA.P.N.#: 770-310-0120.05512 ft²31.3 gpm47.7 psiRESIDENTIAL2Wet12.91 ft/s0 gpm26.3 gpm5 gpm0 gpm0 gpm31.3 gpm0 gpm31.3 gpm47.7 psi83.9 psi36.2 psi GENERAL NOTESAPPROVED.AND THE SYSTEM RISER TO BE COPPER TUBING .RESIDENTIAL FIRE SPRINKLERS SHALL BE VIKING FREE-RES SIN #VK468.1. THE DESIGN, EQUIPMENT, MATERIALS, INSTALLATION AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) PAMPHLET 13D2016ed. AND THE LOCAL CITY FIRE REQUIREMENTS.ALL MATERIALS SHALL BE NEW AND UL LISTED AND/OR FACTORY MUTUAL ALL PIPINGS SHALL BE CPVC PLASTIC ASTM F-442 UNLESS NOTED OTHERWISEFITTINGS SHALL BE CPVC PLASTIC F-437 AND/OR COPPER FITTING. LESS THAN 8 FT. GREATER THAN 16 FT. BE GREATER THAN 8 FT.TWO (2) HOURS.FROM PAINTING ARE NOT IN CONTRACT.EXACT LOCATIONS SHALL BE DETERMINED ON THE PROJECT SITE.SUPERVISION (IF REQUIRED) ARE NOT IN CONTRACT.THE DIMENSIONS FOR THE AUTOMATIC FIRE SPRINKLERS AND RELATED PIPING ANDDEVICE LOCATIONS APPLIES TO THE GENERAL ARRANGEMENT OF THE SYSTEM.THE ELECTRIC WIRING, DETECTION SUPERVISORY SYSTEM AND CENTRAL STATIONPREPARATION FOR, PAINTING AND THE PROTECTION OF SPRINKLERS AND DEVICES (MINIMUM FLOW RATES @ 16 FT X 16 FT COVERAGE = 13.0 GPM @ 7.0 PSI MULTIPLE HEADS) a. THE MAXIMUM RESIDENTIAL SPRINKLER SPACING OFF A WALL SHALL NOT b. THE MAXIMUM DISTANCE BETWEEN ANY TWO (2) SPRINKLERS SHALL NOT BE c. THE MINIMUM DISTANCE BETWEEN ANY TWO (2) SPRINKLERS SHALL NOT BE THE NEW FIRE SPRINKLER SYSTEM SHALL BE FLUSHED UNTIL CLEAR.THE SYSTEM SHALL BE HYDROSTATICALLY TESTED FOR LEAKAGE @ 200 PSI FORPENDENT SPRINKLER, 155 F, 1/2" ORIFICE, 1/2" NPT, K-FACTOR 4.910.11.12.8.9.7.2.5.4.3.GARAGE FIRE SPRINKLERS SHALL BE VIKING FREE-RES #VK468.PENDENT SPRINKLER, 175 F, 1/2" ORIFICE, 1/2" NPT, K-FACTOR 4.9.6.UNDERGROUND FIRE SERVICE FLUSH TO BE WITNESSED BY THE LOCAL JURISDICTION.13.14.PILOT HEADS TO BE AT ATTIC ACCESS DOOR OR FAU IN ATTIC.This system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat point of connection.Hose stream allowance ofis included in the above.2BEDROOM 2DESERT FIRE9/27/22SMITH RESIDENCEA.P.N.#: 770-310-0120.05400 ft²26 gpm48.8 psiRESIDENTIAL1Wet10.74 ft/s0 gpm21 gpm5 gpm0 gpm0 gpm26 gpm0 gpm26 gpm48.8 psi83.9 psi35.1 psiFIRE SPRINKLERS IN BEAM POCKETS SHALL BE VIKING FREE-RES SIN #VK496.PENDENT SPRINKLER, 155 F, 1/2" ORIFICE, 1/2" NPT, K-FACTOR 3.0. LESS THAN 8 FT. GREATER THAN 12 FT. BE GREATER THAN 6 FT.(MINIMUM FLOW RATES @ 12 FT X 12 FT COVERAGE = 8.0 GPM @ 7.1 PSI MULTIPLE HEADS) d. THE MAXIMUM RESIDENTIAL SPRINKLER SPACING OFF A WALL SHALL NOT e. THE MAXIMUM DISTANCE BETWEEN ANY TWO (2) SPRINKLERS SHALL NOT BE f. THE MINIMUM DISTANCE BETWEEN ANY TWO (2) SPRINKLERS SHALL NOT BE TOTAL HEADS = 69FIRE RISER LOCATIONMECHANICAL HEAT REGISTERAN1W09/26/202278623 PEARLESS PLACECOACHELLA VALLEY WATER DISTRICT84.000.0083.00100.00Source Data PointsPump Data PointsSource InformationPressureFlowPressureFlowDate of Flow Test / Info :Location of flow test data :Source of flow test data :00600812C-16 CALIFORNIA563921LICENSE NO.D E S ERT-FIREFIRE PROTECTION CONT R ACTOR SHEET INDEX:FP1 - GENERAL NOTES/SITE PLANFP2 - HANGER DETAILS/SECTION VIEWSFP3 - PIPING PLAN\ REFLECTED CEILING PLANNOT REQUIRED - STATIC PRESSURE ACCEPTEDNOT REQUIRED - OPTIONALAPPROVEDRwinscot11/02/2022 9:22:47 AMRiverside County Fire DepartmentOffice of the Fire MarshalBy:Rebecca WinscottDigitally signed by Rebecca WinscottDN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca WinscottDate: 2021.09.10 13:10:33-07'00'Fire Safety Specialist FIRE RISER LOCATIONMECHANICAL HEAT REGISTERTOTAL HEADS = 69CEILINGDISTANCE FROM SPINKLER TO MAX DISTANCE OF DEFLECTOR TOSIDE OF OBSTRUCTION (A) BOTTOM OF OBSTRUCTION (B)LESS THAN 1 FT 0"1 FT TO LESS THAN 1'6" 0"1'6" TO LESS THAN 2FT 1"2 FT TO LESS THAN 2'6" 1"2'6" TO LESS THAN 3FT 1"3FT TO LESS THAN 3'6" 3"3'6" TO LESS THAN 4 FT 3"4 FT TO LESS THAN 4'6" 5"4'6" TO LESS THAN 5 FT 7"5' TO LESS THAN 5'6" FT 7"5'6 TO LESS THAN 6' FT 7"6' TO LESS THAN 6'6" FT 9"6'6" TO LESS THAN 7' FT 11"7' FT AND GREATER 14"CEILINGA>(D-8 in.)+B[A<(D-0.2m)+B]D<30in. (0.8m)002011H101001012010N.T.S.HANGER DETAILHANGER DETAIL1D4.1627121D4.1121D4.127615D4.12712622221D4.127121D4.1612x1612"3 1/2"12"3 1/2"MECH.OWNER'S BATHWICHALLGREAT ROOM 23DINING RM.KITCHENPANTRY23'-6"14'-5"17'-0 1/2"18'-6 5/8"2'-0"1'-6"9'-1"2'-0"11'-1"10'-1"9'-1"1'-9"10'-1"10x1210x1210x1210x1210x1212'-1" 12'-1" 10'-1" 8'-0" 10'-1" 15'-3 1/2" 18'-8 1/2" 23'-6"C-16 CALIFORNIA563921LICENSE NO.D E S ERT-FIREFIRE PROTECTION CONT R ACTOR NOT REQUIRED - OPTIONALAPPROVEDRwinscot11/02/2022 9:22:48 AMRiverside County Fire DepartmentOffice of the Fire MarshalBy:Rebecca WinscottDigitally signed by Rebecca WinscottDN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca WinscottDate: 2021.09.10 13:10:33-07'00'Fire Safety Specialist FPFPFP+10' CEILING+11' CEILING+10' CEILING+9' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+9' CEILING+10' CEILINGSLOPESLOPESLOPESLOPE ARCH+10' CEILING+9' CEILING+9' CEILING+10' CEILING+9' CEILING+10' CEILING+12' CEILING+10' CEILING+9' CEILING+9' CEILING+10' CEILING+10' CEILING+11' CEILING+10' CEILING+12' CEILING+11' CEILING+12' CEILING+11' CEILING+9' CEILING+11' CEILING+12' CEILING+10'+10'+10'+10'+10'+11' CEILING+10' CEILING+10'+12' CEILINGHEATERHEATER HEATER12x1610x1210x1210x1210x1210x1210x1210x1210x1210x1210x128x108x108x108x10 8x108x108x108x108x108x1010x14 22"x30"ATTICACCESS22"x30"ATTICACCESS22"x30"ATTICACCESSOWNER SUITESS SWINEELECT.GOLF CARTENTRY COURTCASITATHEATERPOWDERENTRYFOYERMECH.OWNER'S BATHWICWCWCCOVERED LOGGIAPREPKITCHENPANTRYKITCHENWICWICWICHALLHALLLAUNDRYA/VBATH 2BEDROOM 2GREAT ROOMVANITYWHWHBBQPATIOHALLHALLBEDROOM 3REF.LINEN DESKPATIOGARAGEHALLVESTIBULEBATH 4PATIOBATH 3LINENCOATSDWDW DININGROOMSHOWERWW123H1011,2002001010011012028013025091053140061063064FIRE RISER LOCATIONMECHANICAL HEAT REGISTERTOTAL HEADS = 69FPFPFP+10' CEILING+11' CEILING+10' CEILING+9' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+10' CEILING+9' CEILING+10' CEILINGSLOPESLOPESLOPE SLOPE ARCH+10' CEILING+9' CEILING+9' CEILING+10' CEILING+9' CEILING+10' CEILING+12' CEILING+10' CEILING+9' CEILING+9' CEILING+10' CEILING+10' CEILING+11' CEILING+10' CEILING+12' CEILING+11' CEILING+12' CEILING+11' CEILING+9' CEILING+11' CEILING+12' CEILING+10'+10'+10'+10'+10'+11' CEILING+10' CEILING+10'+12' CEILINGHEATER HEATER HEATER12x1610x12 10x12 10x12 10x12 10x12 10x12 10x12 10x12 10x12 10x12 8x108x108x108x108x108x108x108x108x108x1010x14 22"x30"ATTICACCESS22"x30"ATTICACCESS22"x30"ATTICACCESSOWNER SUITES S SWINEELECT.GOLF CARTENTRY COURTCASITATHEATERPOWDERENTRYFOYERMECH.OWNER'S BATHWICWCWCCOVERED LOGGIAPREPKITCHENPANTRYKITCHENWICWICWICHALLHALLLAUNDRYA/VBATH 2BEDROOM 2GREAT ROOMVANITYWHWHBBQPATIOHALLHALLBEDROOM 3REF.LINEN DESKPATIOGARAGEHALLVESTIBULEBATH 4PATIOBATH 3LINENCOATSDWDW DININGROOMSHOWERWWC-16 CALIFORNIA563921LICENSE NO.D E S ERT-FIREFIRE PROTECTION CONT R ACTOR ATTIC/FAU HEADS OPTIONAL - NOT REQUIREDAPPROVEDRwinscot11/02/2022 9:22:48 AMRiverside County Fire DepartmentOffice of the Fire MarshalBy:Rebecca WinscottDigitally signed by Rebecca WinscottDN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca WinscottDate: 2021.09.10 13:10:33-07'00'Fire Safety Specialist Project Name : SMITH RESIDENCE Contract No. : Project Location: A.P.N.#: 770-310-012 City: LA QUINTA, CA CALCULATION SUMMARY Design Areas Design Area Name Min. Density Area of Application Occupancy Calculated Heads Min. Pressure Hose Streams Total Water Pressure @ Source Margin To Source (gpm/ft²)(ft²)#(psi)(gpm)(gpm)(psi)(psi) Min. Flow (gpm) Calc. Mode (Model) 1 RESIDENTIAL 512 31.3 Required 47.7 0.051 13 2 5 36.27Demand (HW) 2 RESIDENTIAL 400 26 Required 48.8 0.053 21 1 5 35.118.4Demand (HW) Date 10/4/2022 Page 1Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Required Pressure at Source (psi) Type of System Volume - Entire System (gal) 1 DINING ROOM RESIDENTIAL 0.051 512 256 2 0 5 31.3 47.7 Wet 38.3 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 09/26/2022 78623 PEARLESS PLACE W 2 HEAD CALC Project Name : SMITH RESIDENCE Contract No. : Project Location: A.P.N.#: 770-310-012 City: LA QUINTA, CA Date: 9/27/2022 Name of Contractor: DESERT FIRE Address: 558 E INDUSTRIAL PLACE Phone Number: 760-322-0995 Name of Designer: BJ Authority Having Jurisdiction: City: PALM SPRINGS, CA E-mail: Job Information Contractor Information Notes Date 10/4/2022 Page 2Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Diagram for Design Area : 1 (Optimized Hydraulic Simplified) Node Labels: Pipe Labels: Off Off Date 10/4/2022 Page 3Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Hydraulic Analysis for : 1 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : W Flow (gpm)Pressure (psi) 0 84 100 83 Node at Source Static Pressure (psi) Residual Pressure (psi) Flow (gpm) Available Pressure (psi) Total Demand (gpm) Required Pressure (psi) Supply Analysis W 84 83 100 83.9 31.3 47.7 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 5 0 0 5 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 26.3 0 0 26.3 Required Margin of Safety (%) W - Pressure (psi) W - Flow (gpm) Demand w/o System Pump(s) 10 47.7 31.3 N/A Sprinklers Other Date 10/4/2022 Page 4Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Hydraulic Analysis for : 1 Date 10/4/2022 Page 5Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Hydraulic Analysis for : 1 Pressure (psi)Label Graph Labels Flow (gpm) Values Description 0S1 84Supply point #1 - Static 100S2 83Supply point #2 - Residual 0D1 6.1Elevation Pressure 31.3D2 47.7System Demand Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 43.9Supply83.8 36.2 31.3 41.3Supply; Safety Pressure 75.4 27.8 31.3 Open Heads Head Ref. DensityDensity K-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required Calculated Head Type 1 4.9 0.05 12.8 7 0.051 713256Overhead Sprinkler 2 4.9 0.05 12.8 7 0.052 7.413.3256Overhead Sprinkler Date 10/4/2022 Page 6Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Elev ft Type Hgroup K-Fact. Open/Closed gpm/psi½ Discharge Overdischarge gpm gpm Coverage Density ft² gpm/ft² Tot. Pres. Elev. Pres. psi psi Req. Pres. Req. Discharge psi gpm 001 2 Node NODE 25.1 -1.7 002-I 1.45 Node NODE 25.4 -1.5 002-O 1.55 Node NODE 25.4 -1.5 006-I -1.5 Node NODE 34 -0.2 006-O -1.5 Node NODE 29.9 -0.2 008 -2 Node NODE 47.7 0 010-I 2.95 Node NODE 24.5 -2.1 010-O 3.05 Node NODE 24.4 -2.2 011-I 6.97 Node NODE 21.8 -3.9 011-O 7.07 Node NODE 18.8 -3.9 012 10.5 Node NODE 16.6 -5.4 013 10.5 Node NODE 14.7 -5.4 025 10.5 Node NODE 13.2 -5.4 028 10.5 Node NODE 13.4 -5.4 053 12.5 Node NODE 8.4 -6.3 061 10.5 Node NODE 11.1 -5.4 063 10.5 Node NODE 11.2 -5.4 091 10.5 Node NODE 13.1 -5.4 1 12 Overhead Sprinkler HEAD 4.9 Open 13 0.2 256 0.051 7 -6.1 7 12.8 140 12.5 Node NODE 7.4 -6.3 2 12 Overhead Sprinkler HEAD 4.9 Open 13.3 0.5 256 0.052 7.4 -6.1 7 12.8 AN1 -1.5 Forced Node FNODE 37.8 -0.2 H101 2 Inside Hose HOSE 5 25 -1.7 5 W -2 Supply SUPPLY -31.3 47.7 0 Date 10/4/2022 Page 7Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Hydraulic CalculationsJob : SMITH RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 1 140 12 12.5 4.9 13 13 1 1.101 1x(BM.Tee-Run)=1 1x(BM.90)=5 12.83 6 18.83 150 0.0304 7 -0.2 0.6 140 053 12.5 12.5 13.3 26.3 1 1.101 1x(BM.Tee-Br)=5 4.17 5 9.17 150 0.1125 7.4 0 1 053 061 12.5 10.5 -11 15.3 1 1.101 4x(BM.Tee-Run)=4 3x(BM.90)=15 24.94 19 43.94 150 0.0411 8.4 0.9 1.8 061 091 10.5 10.5 -6.9 8.4 1 1.101 10x(BM.Tee-Run)=10 2x(BM.Tee-Br)=10 7x(BM.90)=35 95.35 55 150.35 150 0.0135 11.1 0 2 091 025 10.5 10.5 6.9 15.3 1 1.101 1x(BM.Tee-Run)=1 1.73 1 2.73 150 0.0411 13.1 0 0.1 025 013 10.5 10.5 -7.2 8.1 1 1.101 6x(BM.Tee-Run)=6 5x(BM.90)=25 1x(BM.Tee-Br)=5 84.57 36 120.57 150 0.0126 13.2 0 1.5 013 012 10.5 10.5 18.2 26.3 1 1.101 1x(us.90)=3.82 12.58 3.82 16.41 150 0.1125 14.7 0 1.8 012 011-O 10.5 7.07 0 26.3 1 1.049 3.43 0 3.43 120 0.2152 16.6 1.5 0.7 011-O 011-I 7.07 6.97 0 26.3 1 0 0.1 0 0.1 28.5714 18.8 0.0 3 Potter Flow *** 011-I 010-O 6.97 3.05 0 26.3 1 1.049 3.92 0 3.92 120 0.2152 21.8 1.7 0.8 010-O 010-I 3.05 2.95 0 26.3 1 0 0.11 0 0.11 0.3939 24.4 0.0 0.0 Rubber-check *** 010-I 001 2.95 2 0 26.3 1 1.049 0.95 0 0.95 120 0.2152 24.5 0.4 0.2 001 002-O 2 1.55 5 31.3 1 0.995 0.45 0 0.45 150 0.2542 25.1 0.2 0.1 002-O 002-I 1.55 1.45 0 31.3 1 0 0.1 0 0.1 0 25.4 0.0 0 GATE VALVE *** 002-I 006-O 1.45 -1.5 0 31.3 1.5 1.598 4x(BM.90)=32 94.78 32 126.78 150 0.0253 25.4 1.3 3.2 006-O 006-I -1.5 -1.5 0 31.3 1 0 0.11 0 0.11 38.8199 29.9 0 4.1 METER-NFPA *** Date 10/4/2022 Page 8Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Hydraulic CalculationsJob : SMITH RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 006-I AN1 -1.5 -1.5 0 31.3 1 0.995 1x(fm.Angle)=14.01 0.95 14.01 14.96 150 0.2542 34 0 3.8 AN1 008 -1.5 -2 0 31.3 1 0.995 1x(us.Tee-Br)=5.84 1x(us.90)=2.33 29.81 8.17 37.99 150 0.2542 37.8 0.2 9.7 008 W -2 -2 0 31.3 4 4.11 1 0 1 150 0.0003 47.7 0 0 W 47.7 2Path No: 2 140 12 12.5 4.9 13.3 13.3 1 1.101 1x(BM.Tee-Br)=5 0.5 5 5.5 150 0.0319 7.4 -0.2 0.2 140 7.4 3Path No: H101 001 2 2 5 5 1 0.995 1x(us.Tee-Br)=5.84 1 5.84 6.84 150 0.0085 25 0 0.1 001 25.1 4Path No: 053 028 12.5 10.5 0 11 1 1.101 4x(BM.Tee-Br)=20 11x(BM.Tee-Run)=11 7x(BM.90)=35 120.42 66 186.42 150 0.0225 8.4 0.9 4.2 028 013 10.5 10.5 7.2 18.2 1 1.101 1x(BM.Tee-Run)=1 1x(BM.Tee-Br)=5 16.33 6 22.33 150 0.0571 13.4 0 1.3 013 14.7 5Path No: 061 063 10.5 10.5 0 6.9 1 1.101 1x(BM.Tee-Run)=1 1x(BM.90)=5 13.17 6 19.17 150 0.0094 11.1 0 0.2 063 091 10.5 10.5 0 6.9 1 1.101 13x(BM.Tee-Run)=13 8x(BM.90)=40 4x(BM.Tee-Br)=20 124.23 73 197.23 150 0.0094 11.2 0 1.9 091 13.1 6Path No: 025 028 10.5 10.5 0 7.2 1 1.101 2x(BM.Tee-Run)=2 1x(BM.Tee-Br)=5 16.85 7 23.85 150 0.0102 13.2 0 0.2 028 13.4 Date 10/4/2022 Page 9Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Hydraulic CalculationsJob : SMITH RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. *** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. * Maximum Velocity of 12.91 ft/s occurs in the following pipe(s): (002-O-001), (AN1-006-I), (008-AN1) Date 10/4/2022 Page 10Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:48 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Device GraphsJob : SMITH RESIDENCE Date 10/4/2022 Page 11Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Device GraphsJob : SMITH RESIDENCE Date 10/4/2022 Page 12Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Device GraphsJob : SMITH RESIDENCE Date 10/4/2022 Page 13Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Required Pressure at Source (psi) Type of System Volume - Entire System (gal) 2 BEDROOM 2 RESIDENTIAL 0.053 400 400 1 0 5 26 48.8 Wet 37.9 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 09/26/2022 78623 PEARLESS PLACE W 1 HEAD CALC Project Name : SMITH RESIDENCE Contract No. : Project Location: A.P.N.#: 770-310-012 City: LA QUINTA, CA Date: 9/27/2022 Name of Contractor: DESERT FIRE Address: 558 E INDUSTRIAL PLACE Phone Number: 760-322-0995 Name of Designer: BJ Authority Having Jurisdiction: City: PALM SPRINGS, CA E-mail: Job Information Contractor Information Notes Date 10/4/2022 Page 14Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Diagram for Design Area : 2 (Optimized Hydraulic Simplified) Node Labels: Pipe Labels: Off Off Date 10/4/2022 Page 15Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Hydraulic Analysis for : 2 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : W Flow (gpm)Pressure (psi) 0 84 100 83 Node at Source Static Pressure (psi) Residual Pressure (psi) Flow (gpm) Available Pressure (psi) Total Demand (gpm) Required Pressure (psi) Supply Analysis W 84 83 100 83.9 26 48.8 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 5 0 0 5 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 21 0 0 21 Required Margin of Safety (%) W - Pressure (psi) W - Flow (gpm) Demand w/o System Pump(s) 10 48.8 26 N/A Sprinklers Other Date 10/4/2022 Page 16Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Hydraulic Analysis for : 2 Date 10/4/2022 Page 17Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Hydraulic Analysis for : 2 Pressure (psi)Label Graph Labels Flow (gpm) Values Description 0S1 84Supply point #1 - Static 100S2 83Supply point #2 - Residual 0D1 5.2Elevation Pressure 26D2 48.8System Demand Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 35.8Supply83.9 35.1 26 33.7Supply; Safety Pressure 75.5 26.7 26 Open Heads Head Ref. DensityDensity K-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required Calculated Head Type 3 4.9 0.05 20 18.4 0.053 18.421400Overhead Sprinkler Date 10/4/2022 Page 18Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Job : SMITH RESIDENCE Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Elev ft Type Hgroup K-Fact. Open/Closed gpm/psi½ Discharge Overdischarge gpm gpm Coverage Density ft² gpm/ft² Tot. Pres. Elev. Pres. psi psi Req. Pres. Req. Discharge psi gpm 3 10 Overhead Sprinkler HEAD 4.9 Open 21 1 400 0.053 18.4 -5.2 18.4 20 064 10.5 Node NODE 19.6 -5.4 061 10.5 Node NODE 20.4 -5.4 091 10.5 Node NODE 21.9 -5.4 025 10.5 Node NODE 22 -5.4 028 10.5 Node NODE 22.3 -5.4 013 10.5 Node NODE 23.1 -5.4 012 10.5 Node NODE 24.3 -5.4 011-O 7.07 Node NODE 26.3 -3.9 011-I 6.97 Node NODE 29.3 -3.9 010-O 3.05 Node NODE 31.6 -2.2 010-I 2.95 Node NODE 31.6 -2.1 H101 2 Inside Hose HOSE 5 32.1 -1.7 5 001 2 Node NODE 32.2 -1.7 002-O 1.55 Node NODE 32.5 -1.5 002-I 1.45 Node NODE 32.5 -1.5 006-O -1.5 Node NODE 36.1 -0.2 006-I -1.5 Node NODE 39.1 -0.2 AN1 -1.5 Forced Node FNODE 41.8 -0.2 008 -2 Node NODE 48.8 0 W -2 Supply SUPPLY -26 48.8 0 Date 10/4/2022 Page 19Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Hydraulic CalculationsJob : SMITH RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 3 064 10 10.5 4.9 21 21 1 1.101 1x(BM.Tee-Run)=1 2x(BM.90)=10 8.21 11 19.21 150 0.0743 18.4 -0.2 1.4 064 061 10.5 10.5 -7.8 13.2 1 1.101 2x(BM.Tee-Run)=2 1x(BM.90)=5 19.44 7 26.44 150 0.0315 19.6 0 0.8 061 091 10.5 10.5 -6.3 6.9 1 1.101 10x(BM.Tee-Run)=10 2x(BM.Tee-Br)=10 7x(BM.90)=35 95.35 55 150.35 150 0.0095 20.4 0 1.4 091 025 10.5 10.5 7.8 14.7 1 1.101 1x(BM.Tee-Run)=1 1.73 1 2.73 150 0.0385 21.9 0 0.1 025 028 10.5 10.5 -6.8 8 1 1.101 2x(BM.Tee-Run)=2 1x(BM.Tee-Br)=5 16.85 7 23.85 150 0.0123 22 0 0.3 028 013 10.5 10.5 6.3 14.2 1 1.101 1x(BM.Tee-Run)=1 1x(BM.Tee-Br)=5 16.33 6 22.33 150 0.0361 22.3 0 0.8 013 012 10.5 10.5 6.8 21 1 1.101 1x(us.90)=3.82 12.58 3.82 16.41 150 0.0743 23.1 0 1.2 012 011-O 10.5 7.07 0 21 1 1.049 3.43 0 3.43 120 0.1422 24.3 1.5 0.5 011-O 011-I 7.07 6.97 0 21 1 0 0.1 0 0.1 28.5714 26.3 0.0 3 Potter Flow *** 011-I 010-O 6.97 3.05 0 21 1 1.049 3.92 0 3.92 120 0.1422 29.3 1.7 0.6 010-O 010-I 3.05 2.95 0 21 1 0 0.11 0 0.11 0.1579 31.6 0.0 0.0 Rubber-check *** 010-I 001 2.95 2 0 21 1 1.049 0.95 0 0.95 120 0.1422 31.6 0.4 0.1 001 002-O 2 1.55 5 26 1 0.995 0.45 0 0.45 150 0.1806 32.2 0.2 0.1 002-O 002-I 1.55 1.45 0 26 1 0 0.1 0 0.1 0 32.5 0.0 0 GATE VALVE *** 002-I 006-O 1.45 -1.5 0 26 1.5 1.598 4x(BM.90)=32 94.78 32 126.78 150 0.018 32.5 1.3 2.3 006-O 006-I -1.5 -1.5 0 26 1 0 0.11 0 0.11 28.5799 36.1 0 3 METER-NFPA *** Date 10/4/2022 Page 20Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Hydraulic CalculationsJob : SMITH RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 006-I AN1 -1.5 -1.5 0 26 1 0.995 1x(fm.Angle)=14.01 0.95 14.01 14.96 150 0.1806 39.1 0 2.7 AN1 008 -1.5 -2 0 26 1 0.995 1x(us.Tee-Br)=5.84 1x(us.90)=2.33 29.81 8.17 37.99 150 0.1806 41.8 0.2 6.9 008 W -2 -2 0 26 4 4.11 1 0 1 150 0.0002 48.8 0 0 W 48.8 2Path No: H101 001 2 2 5 5 1 0.995 1x(us.Tee-Br)=5.84 1 5.84 6.84 150 0.0085 32.1 0 0.1 001 32.2 3Path No: 064 091 10.5 10.5 0 7.8 1 1.101 13x(BM.Tee-Run)=13 8x(BM.90)=40 4x(BM.Tee-Br)=20 117.96 73 190.96 150 0.0119 19.6 0 2.3 091 21.9 4Path No: 061 028 10.5 10.5 0 6.3 1 1.101 4x(BM.Tee-Br)=20 15x(BM.Tee-Run)=15 10x(BM.90)=50 145.35 85 230.35 150 0.0079 20.4 0 1.8 028 22.3 5Path No: 025 013 10.5 10.5 0 6.8 1 1.101 6x(BM.Tee-Run)=6 5x(BM.90)=25 1x(BM.Tee-Br)=5 84.57 36 120.57 150 0.0091 22 0 1.1 013 23.1 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. *** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. * Maximum Velocity of 10.74 ft/s occurs in the following pipe(s): (002-O-001), (AN1-006-I), (008-AN1) Date 10/4/2022 Page 21Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Device GraphsJob : SMITH RESIDENCE Date 10/4/2022 Page 22Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Device GraphsJob : SMITH RESIDENCE Date 10/4/2022 Page 23Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Device GraphsJob : SMITH RESIDENCE Date 10/4/2022 Page 24Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\draw4\OneDrive\22-DESERT-FIRE\SMITH RESIDENCE\SMITH-RES-FIRE.dwg APPROVED Rwinscot 11/02/2022 9:22:49 AM Riverside County Fire Department Office of the Fire Marshal By:Rebecca Winscott Digitally signed by Rebecca Winscott DN: C=US, E=rebecca.winscott@fire.ca.gov, OU=Riverside County Fire Department, CN=Rebecca Winscott Date: 2021.09.10 13:10:33-07'00' Fire Safety Specialist Brittany Smith <brittany@desert-fire.com> Static Pressure 770-310-012 Lot 35 78-623 Peerless Place Tyler Hull <THull@cvwd.org>Mon, Sep 26, 2022 at 10:40 AM To: Brittany Smith <brittany@desert-fire.com>, Development Services <DevelopmentServices@cvwd.org> Hi Brittany- The calculated Static Pressure at Lot 35 located at 78623 Peerless Place in the City of La Quinta is nearly 85 psi. Tyler Hull Utility Coordinator Coachella Valley Water District 760-398-2661 ext. 2571 www.cvwd.org From: Brittany Smith <brittany@desert-fire.com> Sent: Monday, September 26, 2022 9:39 AM To: Development Services <DevelopmentServices@cvwd.org> Subject: Static Pressure 770-310-012 Lot 35 78-623 Peerless Place External e-mail: Do not click on links or open attachments unless you recognize the sender and you know the content is safe. Good Morning Can I please request Static Pressure for the following: 770-310-012 Lot 35 78-623 Peerless Place -- Brittany Smith Operation Manager Desert Fire Extinguisher Co. Inc (760) 322-0995 760-774-0469 www.desert-fire.com brittany@desert-fire.com 558 E Industrial Pl Palm Springs CA 92264 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 2, 2022 Desert Fire Re: Residential Fire Sprinkler Plan Review – Smith Residence FSS2022-0354 (78623 Peerless) The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Rebecca Winscott - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78623 Peerless PERMIT#: FSS2022-0354 DATE ISSUED: 11/02/22 DESCRIPTION: Smith Residence CONTRACTOR: Desert Fire HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.