FSS2022-0357ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY, STE D INDIO CA 92201 (760)775-6220 JD@JDMECHANICAL.C O CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY, STE D INDIO CA 92201 (760)775-6220 JD@JDMECHANICAL.C O CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 10/20/2022 10/20/2022 Regarding the above permit submittal. Do you have the hydraulic calcs for review? If so please attach to the permit number above. CONDITIONS Description: DISCOVERY / FIRE SPRINKLERS / BRES2021-0894 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: ISSUED Applied: 10/20/2022 ECON Parcel No: 767700033 Site Address: 53515 PIKE PL LA QUINTA,CA 92253 Approved: 12/17/2022 KHET Subdivision: TR 33076-2 Block: Lot: 81 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $25,000.00 Occupancy Type: Construction Type: Expired: 8/22/2023 LRO No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Tuesday, July 18, 2023 4:34:00 PM 1 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0357 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL OWNER DISCOVERY BUILDERS 78140 CALLE TAMPICO LA QUINTA,CA 92253 (760)775-6220 KATHY@JDMECHANIC AL INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 2/22/23 WEB14428 819765425 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $250.00 $250.00 12/27/22 WEB13911 777349132 CREDIT 1020141 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 12/27/22 WEB13911 777349132 CREDIT 1020141 ECON Total Paid for FIRE FEES: $675.00 $675.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 12/27/22 WEB13911 777349132 CREDIT 1020141 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 12/27/22 WEB13911 777349132 CREDIT 1020141 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$694.00 $694.00 Printed: Tuesday, July 18, 2023 4:34:00 PM 2 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0357 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL FP-2 Lot 81B.pdf1st Floor Piping.pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL FP-3 Lot 81B.pdf2nd Floor Piping.pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL FP-4 Lot 81B.pdfDetails.pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL FP-1 Lot 81B.pdfSite Plan.pdf 1 BOND INFORMATION OVERHEAD ROUGH PIPING LRO 2/21/2023 2/21/2023 DISAPPROVE D See Notes Missing Sprinkler head in entry way on second floor entering into bedroom 3. As Builts are required to be obtained prior to scheduling a final. OVERHEAD HYRO LRO 2/21/2023 2/22/2023 DISAPPROVE D OVERHEAD ROUGH PIPING LRO 2/22/2023 2/22/2023 APPROVED OVERHEAD HYRO LRO 2/22/2023 2/22/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) REBECCA WINSCOTT 10/20/2022 11/3/2022 11/14/2022 REVISIONS REQUIRED Emailed applicant and requested hydraulic calcs that were not uploaded 1ST PERMIT TECH – ETRAKIT (1 DAY) AARON HICKSON 10/20/2022 10/21/2022 10/21/2022 COMPLETE 2ND FIRE (1 WK)KOHL HETRICK 11/16/2022 11/23/2022 12/17/2022 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Tuesday, July 18, 2023 4:34:00 PM 3 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0357 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL PENDANT Senju Residential Conceled Pendant lot 81.pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL CVWD Document_2022-09- 22_114051 connection for 81 .pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL APPLICATION Document_2022-10- 20_115557 LQ APP LOT 81.pdf 1 DOC 10/20/2022 Etrakit Contractor Document_2022-09- 22_114051 connection for 81_1.pdf 1 DOC 12/13/2022 Etrakit Contractor Document.pdfCalc-1 81 as built.pdf 1 DOC 12/13/2022 Etrakit Contractor Document_2022-09- 22_114051 connection for 81 _1.pdf 1 DOC 12/13/2022 Etrakit Contractor Lot 81B.pdf1st Floor Piping 1st Corr.pdf 1 DOC 12/13/2022 Etrakit Contractor Lot 81B.pdf2nd Floor Piping 1st Corr.pdf 1 DOC 12/13/2022 Etrakit Contractor Lot 81B.pdfDetail 1st Correction.pdf 1 DOC 12/13/2022 Etrakit Contractor FP1 Lot 81B.pdfSite 1st Corr.pdf 1 DOC 12/13/2022 Etrakit Contractor PENDENT SPRINKER HEAD Senju Residential Conceled Pendant lot 81 as builts.pdf 1 DOC 12/15/2022 Etrakit Contractor 2ND SUBMITTAL - FP2 1st Floor Piping 2nd Correction x3.pdf 1 Printed: Tuesday, July 18, 2023 4:34:00 PM 4 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0357 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/15/2022 Etrakit Contractor 2ND SUBMITTAL - FP3 2nd Floor Piping 2nd Correctionx3.pdf 1 DOC 12/15/2022 Etrakit Contractor 2ND SUBMITTAL - FP4 Detail 2nd Correctionx2.pdf 1 DOC 12/15/2022 Etrakit Contractor 2ND SUBMITTAL - FP1 Lot 81B.pdfSite 2nd Correction x3.pdf 1 DOC 12/15/2022 Etrakit Contractor 2ND SUBMITTAL - HYDRAULIC CALCS Document.pdfCalc- 1x3.pdf 1 DOC 12/15/2022 Etrakit Contractor CVWD CONNECTION CHARGE ESTIMATE Document_2022-09- 22_114051 connection for 81x3.pdf 1 DOC 12/15/2022 Etrakit Contractor SECOND SUBMITTAL HYDRAULIC CALCS Document.pdfCalc- 2x3.pdf 1 DOC 12/15/2022 Etrakit Contractor SPRINKLER SPECS Senju Residential Conceled Pendantx3.pdf 1 DOC 2/22/2023 Etrakit Contractor Lot 81B.pdf2nd Floor As Builds.pdf 81 ab.pdf 1 DOC 2/22/2023 Etrakit Contractor Lot 81B.pdfDetails As Build.pdf 81 ab.pdf 1 DOC 2/22/2023 Etrakit Contractor Lot 81B.pdfSite As Builds.pdf 81 ab.pdf 1 DOC 2/22/2023 Etrakit Contractor Document.pdfCalc-1.pdf 81 ab.pdf 1 DOC 2/22/2023 Etrakit Contractor Document.pdfCalc-2.pdf 81 ab.pdf 1 DOC 2/22/2023 Etrakit Contractor Document_2022-09- 22_114051 connection for 81.pdf 81 ab.pdf 1 DOC 2/22/2023 Etrakit Contractor Lot 81B.pdf1st Floor As Build.pdf 81ab.pdf 1 Printed: Tuesday, July 18, 2023 4:34:00 PM 5 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0357 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/17/2022 KOHL HETRICK FSS2022-0357 - APPROVED PLANS AND CALCS.pdf FSS2022-0357 - APPROVED PLANS AND CALCS.pdf 1 DOC 12/17/2022 KOHL HETRICK FSS2022-0357 - COA AND JOB CARD.pdf FSS2022-0357 - COA AND JOB CARD.pdf 1 DOC 2/22/2023 LEILANI ROJAS FSS2022-0357 LMR INSP NOTES 2-21-23.pdf FSS2022-0357 LMR INSP NOTES 2-21-23.pdf 1 DOC 11/14/2022 REBECCA WINSCOTT LQ FSS2022-0357 Hydraulic Calculations.pdf LQ FSS2022-0357 Hydraulic Calculations.pdf 1 DOC 11/14/2022 REBECCA WINSCOTT LQ FSS2022-0357 Madison Club Lot 81B.pdf DENIED PLAN LQ FSS2022-0357 Madison Club Lot 81B.pdf 1 Printed: Tuesday, July 18, 2023 4:34:00 PM 6 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0357 1" 1" MASTER BEDROOM 2 W.I.C. W.I.C. MSTR BATH 1 MSTR BATH 2 GARAGE AV LAUNDRY GALLERY KITCHEN MECH 1 PANTRY OUTDOOR LIVING 1 GREAT ROOM HALL MECH 2 PWDR MASTER BEDROOM 1 ENTRY OUTDOOR LIVING 2OPEN TO ABOVE 24'-0" UP TO 2nd FLOOR CEILING DOWN FROM 2nd FLOOR CEILING 1 1/2" 30' -10"1 1/2"58' -6"1 1/2" 15' -6"1 1/2"1' -9"1" 14' -0"1"3' -8"1"5' -6"1" 8' -0" 1" 2' -6"1"5' -10"1" x 11' -6"1" x 4' -6"1"10' -10"1"10' -10"1" 16' -0"1"10' -10"1" 10' -6" 1" 5' -6" 1" 9' -11"1"4' -1"1"3' -8"1" 4' -9" 1" 3' -7" 1" 5' -7" 1" 2' -8"1"2' -8"1"1' -4"1" 9' -6"1" 2' -5"1" x 12' -0"1" 2' -7"1" x 12' -0"1"13' -0"1"2' -0"1"11' -4"1" 12' -7"1"7' -4"1" 1' -5"1"2' -10"1" 2' -10" 1" 8' -6"1"2' -4"1"7' -2"1"0' -9"1"0' -9"1" 16' -0" 1" 10' -0" 1" 16' -0"1"0' -9"1" 0' -10"1"7' -4"1" 3' -4"1"6' -5"1" 9' -5" 1" 14' -0" 1" 12' -0"1"8' -10"1" 12' -0"1"8' -10"1" 1' -5"1"2' -4"1" 10' -3"1"1' -8"1" 8' -0"1"1' -8"1" 10' -3"1"1' -11"1"1' -11"1"3' -3"1"3' -3"1" 12' -10" 1" 3' -4"1"4' -7"1" 0' -10" 1" 12' -9" 1" 1' -0" 1" 3' -1" 1" 10' -5" 1" 3' -7"1"10' -6"1" 8' -0" 1" 1' -11" 1" 0' -5" 1" 10' -11" 1" 1' -1"1"1' -1"1" 6' -4"1"7' -1"1" 0' -8" 1" 1' -0"1" x 7' -0"1" 9' -8"1"2' -8"1" x 12' -0"1"1' -2"1"1' -2"1"1' -2"1" 12' -4"NOTIFICATION DEVICE BY OTHERS1" RISER UP TO 2nd FLOOR CEILING 10 1 BOR DOM 13 129 8 7 6 23 TOR CALC-1 2 FP-21" x 12' -0"jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINC3/16" = 1'-0"12/14/2022 6:18:41 AMFP-2 1st Floor Piping Plan 2nd Correction Project Number LOT 81B 12-14-22 JA JDTHE MADISON CLUBLOT 81B53515 Pike PlaceLa Quinta, Ca. 92253Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 62 Senju1/2 Light Concealed Temperature -162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 9 Senju 1/2 Light Pendent Temperature -205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 71 Total No. of Sprinklers: 71 3/16" = 1'-0"1 1st Floor Piping Plan 3/16" = 1'-0"2 Section 1 NOTE: Section 1 shows up to 2nd Floor FP-2 Piping Plan has this pipe hidden in view 52 52 45 45 45 22 DN 21DN (23)RISERSTREADS11/ "21withBEDROOM 4 BATH 4 BATH 3 W.I.C. BEDROOM 3 W.I.C. STORAGE DECK 1 DECK 2 BRIDGE BED 5 SITTINGBEDROOM 5 BA 5 1" 1" SLOPE 1/4" PER FOOT SLOPE 1/4" PER FOOT SLOPE 1/4"PER FOOTSLOPE 1/4" PER FOOT SLOPE 1/4"PER FOOTSLOPE 1/4"PER FOOTSLOPE 1/4" PER FOOT SLOPE 1/4"PER FOOTWater Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 80.52 psi 66.11 psi 33 GPM 0 GPM 1 1/2" 30' -10"1 1/2"58' -6"1 1/2" 15' -6"1 1/2"1' -9"1"5' -10"1" x 11' -6"1" x 4' -6"1" x 12' -0"1" x 12' -0"1" 6' -3"1"16' -0"1"7' -0"1" 0' -6" 1" 0' -6" 1" 8' -6" 1" 8' -6"1" x 12' -0"1"10' -8"1"12' -2"1"8' -6"1"9' -8"1"10' -1"1" 3' -1"1"3' -7"1" 0' -5" 1" 1' -5" 1" 0' -5" 1" 12' -1" 1" 3' -0" 1" 6' -6"1"6' -0"1"6' -0"1"8' -5"1"8' -5"1" 4' -2" 1" 2' -2"1"6' -0"1" 2' -5"1"7' -6"1" 11' -6"1"8' -0"1"8' -0"1"10' -4"1"0' -4"1"15' -8"1" 0' -4"1" x 12' -0"1" 8' -1" 1" 12' -0"1"6' -6"1" 0' -9" 1" 2' -7" 1" 2' -4"1"6' -6"1"6' -6"1" 3' -1" 1" 9' -7" 1" 4' -0"1"2' -8"1" 7' -6"1"6' -6"1" 1' -7"1"1' -11"1" 1' -4" 1" 1' -4" 1" 12' -2" 1" 8' -10" 1" 4' -0" 1" 3' -10"1"11' -0"1"8' -7"1" 1' -9" UP FROM BELOW UP FROM BELOW UP FROM BELOW OPEN TO BELOW INSPECTORS TEST 1" RISER 10'-0" 10'-0" 10'-0" 10'-0"10'-0"10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"1-1/2" PVC UNDERGROUND BY OTHERSCalc-2 Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 Max SqFt 31.2932 GPM 43.2598 Psi 5 GPM 0 GPM BOR DOM 9 11 TOR 4 5 CORRECTION REFLECT PROPER NODES> NOTE: UNDERGROUND IS AT -3 FEET, MAINS ARE AT 25 FEET BOR AT -3', TOR AT 25'. THIS IS THE PROPER HYDRAULIC CONFIGURATION FOR THE MOST REMOTE AT PROJECTED CEILING HEIGHT. RISER SERVICES BOTH FIRST AND 2ND FLOOR AS SHOWN ON DETAIL FP-4. ADD ACTUAL AS DRAWN RISER SECTION VIEW FP-2 7' - 10"7' - 3" Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-2 2 Gpm/SqFt 512 Max SqFt 31.0858 GPM 44.7739 Psi 5 GPM 0 GPM 16 19 20 1817 12' - 0" 2 FP-2 jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINC3/16" = 1'-0"12/14/2022 6:22:49 AMFP-3 2nd Floor Piping PLan 2nd Correction Project Number LOT 81B 12-14-22 JA JDTHE MADISON CLUBLOT 81B53515 Pike PlaceLa Quinta, Ca 922533/16" = 1'-0"1 2nd Floor Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 62 Senju1/2 Light Concealed Temperature -162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 9 Senju 1/2 Light Pendent Temperature -205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 71 Total No. of Sprinklers: 71 INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" www.cadmando.co.uk These blocks were brought to you by CADB locksFree.com.For all of your 2D & 3D CA D outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL BEDROOM 5 Fire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1-1/2" PVC UG BY OTHERS Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) 1" CPVC 1 1/2" 30' -10"1 1/2"58' -6"1 1/2" 15' -6"1 1/2"1' -9"1"5' -10"1" x 11' -6"1" x 12' -0"1"10' -8"1" 3' -0" 1" 6' -6"1"6' -0"1"6' -0"1" RISER 1" WATER METER 10'-0" 10'-0"1-1/2" PVC UNDERGROUND BY OTHERSBOR DOM 9 TOR WMSOR jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINCAs indicated 12/14/2022 6:23:23 AMFP-4 Details 2nd Correction Project Number LOT 81B 12-14-22 JA JDTHE MADISON CLUBLOT 81B53515 Pike PlaceLa Quinta, Ca. 922533/16" = 1'-0"6 UG 1" 1" MASTER BEDROOM 2 W.I.C. W.I.C. MSTR BATH 1 MSTR BATH 2 GARAGE AV LAUNDRY GALLERY KITCHEN MECH 1 PANTRY OUTDOOR LIVING 1 GREAT ROOM HALL MECH 2 PWDR MASTER BEDROOM 1 ENTRY OUTDOOR LIVING 2OPEN TO ABOVE 24'-0" UP TO 2nd FLOOR CEILING DOWN FROM 2nd FLOOR CEILING 1 1/2" 30' -10"1 1/2"58' -6"1 1/2" 15' -6"1 1/2"1' -9"1" 14' -0"1"3' -8"1"5' -6"1" 8' -0" 1" 2' -6"1"5' -10"1" x 11' -6"1" x 4' -6"1"10' -10"1"10' -10"1" 16' -0"1"10' -10"1" 10' -6" 1" 5' -6" 1" 9' -11"1"4' -1"1"3' -8"1" 4' -9" 1" 3' -7" 1" 5' -7" 1" 2' -8"1"2' -8"1"1' -4"1" 9' -6"1" 2' -5"1" x 12' -0"1" 2' -7"1" x 12' -0"1"13' -0"1"2' -0"1"11' -4"1" 12' -7"1"7' -4"1" 1' -5"1"2' -10"1" 2' -10" 1" 8' -6"1"2' -4"1"7' -2"1"0' -9"1"0' -9"1" 16' -0" 1" 10' -0" 1" 16' -0"1"0' -9"1" 0' -10"1"7' -4"1" 3' -4"1"6' -5"1" 9' -5" 1" 14' -0" 1" 12' -0"1"8' -10"1" 12' -0"1"8' -10"1" 1' -5"1"2' -4"1" 10' -3"1"1' -8"1" 8' -0"1"1' -8"1" 10' -3"1"1' -11"1"1' -11"1"3' -3"1"3' -3"1" 12' -10" 1" 3' -4"1"4' -7"1" 0' -10" 1" 12' -9" 1" 1' -0" 1" 3' -1" 1" 10' -5" 1" 3' -7"1"10' -6"1" 8' -0" 1" 1' -11" 1" 0' -5" 1" 10' -11" 1" 1' -1"1"1' -1"1" 6' -4"1"7' -1"1" 0' -8" 1" 1' -0"1" x 7' -0"1" 9' -8"1"2' -8"1" x 12' -0"1"1' -2"1"1' -2"1"1' -2"1" 12' -4"NOTIFICATION DEVICE BY OTHERS1" RISER UP TO 2nd FLOOR CEILING 10 1 BOR DOM 13 129 8 7 6 23 TOR CALC-1 2 FP-21" x 12' -0"jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINC3/16" = 1'-0"12/14/2022 6:18:41 AMFP-2 1st Floor Piping Plan 2nd Correction Project Number LOT 81B 12-14-22 JA JDTHE MADISON CLUBLOT 81B53515 Pike PlaceLa Quinta, Ca. 92253Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 62 Senju1/2 Light Concealed Temperature -162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 9 Senju 1/2 Light Pendent Temperature -205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 71 Total No. of Sprinklers: 71 3/16" = 1'-0"1 1st Floor Piping Plan 3/16" = 1'-0"2 Section 1 NOTE: Section 1 shows up to 2nd Floor FP-2 Piping Plan has this pipe hidden in view 52 52 45 45 45 22 DN 21DN (23)RISERSTREADS11/ "21withBEDROOM 4 BATH 4 BATH 3 W.I.C. BEDROOM 3 W.I.C. STORAGE DECK 1 DECK 2 BRIDGE BED 5 SITTINGBEDROOM 5 BA 5 1" 1" SLOPE 1/4" PER FOOT SLOPE 1/4" PER FOOT SLOPE 1/4"PER FOOTSLOPE 1/4" PER FOOT SLOPE 1/4"PER FOOTSLOPE 1/4"PER FOOTSLOPE 1/4" PER FOOT SLOPE 1/4"PER FOOTWater Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 80.52 psi 66.11 psi 33 GPM 0 GPM 1 1/2" 30' -10"1 1/2"58' -6"1 1/2" 15' -6"1 1/2"1' -9"1"5' -10"1" x 11' -6"1" x 4' -6"1" x 12' -0"1" x 12' -0"1" 6' -3"1"16' -0"1"7' -0"1" 0' -6" 1" 0' -6" 1" 8' -6" 1" 8' -6"1" x 12' -0"1"10' -8"1"12' -2"1"8' -6"1"9' -8"1"10' -1"1" 3' -1"1"3' -7"1" 0' -5" 1" 1' -5" 1" 0' -5" 1" 12' -1" 1" 3' -0" 1" 6' -6"1"6' -0"1"6' -0"1"8' -5"1"8' -5"1" 4' -2" 1" 2' -2"1"6' -0"1" 2' -5"1"7' -6"1" 11' -6"1"8' -0"1"8' -0"1"10' -4"1"0' -4"1"15' -8"1" 0' -4"1" x 12' -0"1" 8' -1" 1" 12' -0"1"6' -6"1" 0' -9" 1" 2' -7" 1" 2' -4"1"6' -6"1"6' -6"1" 3' -1" 1" 9' -7" 1" 4' -0"1"2' -8"1" 7' -6"1"6' -6"1" 1' -7"1"1' -11"1" 1' -4" 1" 1' -4" 1" 12' -2" 1" 8' -10" 1" 4' -0" 1" 3' -10"1"11' -0"1"8' -7"1" 1' -9" UP FROM BELOW UP FROM BELOW UP FROM BELOW OPEN TO BELOW INSPECTORS TEST 1" RISER 10'-0" 10'-0" 10'-0" 10'-0"10'-0"10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"1-1/2" PVC UNDERGROUND BY OTHERSCalc-2 Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 Max SqFt 31.2932 GPM 43.2598 Psi 5 GPM 0 GPM BOR DOM 9 11 TOR 4 5 CORRECTION REFLECT PROPER NODES> NOTE: UNDERGROUND IS AT -3 FEET, MAINS ARE AT 25 FEET BOR AT -3', TOR AT 25'. THIS IS THE PROPER HYDRAULIC CONFIGURATION FOR THE MOST REMOTE AT PROJECTED CEILING HEIGHT. RISER SERVICES BOTH FIRST AND 2ND FLOOR AS SHOWN ON DETAIL FP-4. ADD ACTUAL AS DRAWN RISER SECTION VIEW FP-2 7' - 10"7' - 3" Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-2 2 Gpm/SqFt 512 Max SqFt 31.0858 GPM 44.7739 Psi 5 GPM 0 GPM 16 19 20 1817 12' - 0" 2 FP-2 jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINC3/16" = 1'-0"12/14/2022 6:22:49 AMFP-3 2nd Floor Piping PLan 2nd Correction Project Number LOT 81B 12-14-22 JA JDTHE MADISON CLUBLOT 81B53515 Pike PlaceLa Quinta, Ca 922533/16" = 1'-0"1 2nd Floor Piping Plan Sprinkler Schedule No. of Sprklrs Description SIN (Hydratec)K-Factor Orifice Size Temp 62 Senju1/2 Light Concealed Temperature -162 Finish - B Quick Response Model - Mirage SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 162 °F 9 Senju 1/2 Light Pendent Temperature -205 Finish - C Special Response Model - Micromatic SIN - SS8464 K Factor - 4.9 SS8464 4.9 1/2" 205 °F : 71 Total No. of Sprinklers: 71 INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" www.cadmando.co.uk These blocks were brought to you by CADB locksFree.com.For all of your 2D & 3D CA D outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL BEDROOM 5 Fire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1-1/2" PVC UG BY OTHERS Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) 1" CPVC 1 1/2" 30' -10"1 1/2"58' -6"1 1/2" 15' -6"1 1/2"1' -9"1"5' -10"1" x 11' -6"1" x 12' -0"1"10' -8"1" 3' -0" 1" 6' -6"1"6' -0"1"6' -0"1" RISER 1" WATER METER 10'-0" 10'-0"1-1/2" PVC UNDERGROUND BY OTHERSBOR DOM 9 TOR WMSOR jd@jdmechanical.co Scale Project number Date Drawn by Checked by 82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220C-16 License # 1020141MECHANICALINCAs indicated 12/14/2022 6:23:23 AMFP-4 Details 2nd Correction Project Number LOT 81B 12-14-22 JA JDTHE MADISON CLUBLOT 81B53515 Pike PlaceLa Quinta, Ca. 922533/16" = 1'-0"6 UG JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Lot 81B Drawing : Location : 53515 Pikes Place Remote Area : Calc-1 Contract : Data File : Lot 81B Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Lot 81BDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 80.52 C2 - Residual Pressure: 66.11 C2 - Residual Flow : 33 D1 - Elevation : 5.713 D2 - System Flow : 31.293 D2 - System Pressure : 43.260 Hose ( Demand ) : _______D3 - System Demand : 31.293 Safety Margin : 24.199 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Lot 81BDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Lot 81B Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure 15 80.52 66.11 33.0 67.458 31.29 43.26 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 10.19 4.9 7.04 13.0 0.05 256 2 13.0 6.49 3 13.0 9.2 4 25.0 5.49 5 25.0 8.58 6 13.0 24.99 7 13.0 26.55 8 13.0 27.09 9 13.0 27.8 DOM 1.53 35.97 5.0 BOR -3.0 39.73 SOR -3.0 43.11 WM -3.0 43.18 14 -3.0 43.24 15 -3.0 43.26 10 10.19 4.9 7.36 13.29 0.05 256 11 25.0 5.63 18 25.0 5.54 20 25.0 5.57 12 13.0 26.57 13 13.0 27.2 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Lot 81B Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 10.19 4.90 13.00 1 N 7.0 13.730 150 7.040 to R 1.0 8.000 -1.217 2 13 13.0 1.101 21.730 0.0306 0.666 Vel = 4.38 2 13 13.29 1 2O 10.0 14.000 150 6.489 to 10.000 0.0 3 13 26.29 1.101 24.000 0.1129 2.709 Vel = 8.86 3 13 -13.55 1 2R 2.0 26.370 150 9.198 to 3O 15.0 24.000 -5.197 4 25 12.74 1.101 N 7.0 50.370 0.0295 1.487 Vel = 4.29 4 25 -3.96 1 11R 11.0 132.230 150 5.488 to 5N 35.0 76.000 0.0 5 25 8.78 1.101 6O 30.0 208.230 0.0148 3.092 Vel = 2.96 5 25 17.51 1 4O 20.0 54.320 150 8.580 to 3N 21.0 45.000 5.197 6 13 26.29 1.101 4R 4.0 99.320 0.1129 11.210 Vel = 8.86 6 13 -10.46 1 2R 2.0 33.360 150 24.987 to 2.000 0.0 7 13 15.83 1.101 35.360 0.0441 1.561 Vel = 5.33 7 13 -2.11 1 16.000 150 26.548 to 0.0 8 13 13.72 1.101 16.000 0.0339 0.542 Vel = 4.62 8 13 -4.83 1 2R 2.0 33.080 150 27.090 to N 7.0 14.000 0.0 9 13 8.89 1.101 O 5.0 47.080 0.0152 0.714 Vel = 3.00 9 13 17.40 1 2O 10.0 17.340 150 27.804 to R 1.0 11.000 4.968 DOM 1.53 26.29 1.101 28.340 0.1129 3.199 Vel = 8.86 DOM 1.53 + 5.00 5.00 1 N 7.0 4.530 150 35.971 to 7.000 1.962 BOR -3 31.29 1.101 11.530 0.1558 1.796 Vel = 10.54 BOR -3 0.0 1.5 3N 27.0 106.350 150 39.729 to 27.000 0.0 SOR -3 31.29 1.598 133.350 0.0254 3.384 Vel = 5.01 SOR -3 0.0 1 0.420 150 43.113 to 0.0 WM -3 31.29 1.101 0.420 0.1571 0.066 Vel = 10.54 WM -3 0.0 1 0.420 150 43.179 to 0.0 14 -3 31.29 1.101 0.420 0.1548 0.065 Vel = 10.54 14 -3 0.0 1.5 0.610 150 43.244 to 0.0 15 -3 31.29 1.598 0.610 0.0262 0.016 Vel = 5.01 0.0 15 31.29 43.260 K Factor = 4.76 10 10.19 4.90 13.29 1 N 7.0 3.890 150 7.359 to 7.000 -1.217 2 13 13.29 1.101 10.890 0.0319 0.347 Vel = 4.48 0.0 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 5 Lot 81B Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 2 13.29 6.489 K Factor = 5.22 3 13 13.56 1 3O 15.0 27.020 150 9.198 to N 7.0 22.000 -5.197 11 25 13.56 1.101 49.020 0.0331 1.625 Vel = 4.57 11 25 3.95 1 3N 21.0 31.530 150 5.626 to 3R 3.0 24.000 0.0 5 25 17.51 1.101 55.530 0.0532 2.954 Vel = 5.90 0.0 5 17.51 8.580 K Factor = 5.98 4 25 3.95 1 O 5.0 8.080 150 5.488 to R 1.0 6.000 0.0 18 25 3.95 1.101 14.080 0.0034 0.048 Vel = 1.33 18 25 0.0 1 R 1.0 10.110 150 5.536 to 1.000 0.0 20 25 3.95 1.101 11.110 0.0034 0.038 Vel = 1.33 20 25 0.0 1 R 1.0 7.340 150 5.574 to N 7.0 8.000 0.0 11 25 3.95 1.101 15.340 0.0034 0.052 Vel = 1.33 0.0 11 3.95 5.626 K Factor = 1.67 6 13 10.47 1 3O 15.0 44.920 150 24.987 to 2N 14.0 32.000 0.0 12 13 10.47 1.101 3R 3.0 76.920 0.0205 1.580 Vel = 3.53 12 13 2.10 1 O 5.0 16.000 150 26.567 to R 1.0 6.000 0.0 13 13 12.57 1.101 22.000 0.0288 0.634 Vel = 4.24 13 13 4.84 1 R 1.0 10.470 150 27.201 to 1.000 0.0 9 13 17.41 1.101 11.470 0.0526 0.603 Vel = 5.87 0.0 9 17.41 27.804 K Factor = 3.30 7 13 2.11 1 O 5.0 11.550 150 26.548 to R 1.0 6.000 0.0 12 13 2.11 1.101 17.550 0.0011 0.019 Vel = 0.71 0.0 12 2.11 26.567 K Factor = 0.41 8 13 4.83 1 2O 10.0 11.550 150 27.090 to R 1.0 11.000 0.0 13 13 4.83 1.101 22.550 0.0049 0.111 Vel = 1.63 0.0 13 4.83 27.201 K Factor = 0.93 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire 82579 Fleming Way Suite D Your Street Address 2 Indio, Ca. 92201 760-775-6220 Job Name : Lot 81B Drawing : Location : 53515 Pike Place Remote Area : Calc-2 Contract : Data File : Lot 81B Area Calc-2.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 1 Lot 81BDate 10203040E50R60U70S80S90E100R110P12013014015010 20 30 40 50 60 70 80 90FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 80.52 C2 - Residual Pressure: 66.11 C2 - Residual Flow : 33 D1 - Elevation : 11.776 D2 - System Flow : 31.086 D2 - System Pressure : 44.774 Hose ( Demand ) : _______D3 - System Demand : 31.086 Safety Margin : 22.844 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical FirePage 2 Lot 81BDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 3 Lot 81B Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure 15 80.52 66.11 33.0 67.618 31.09 44.774 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 16 24.19 4.9 7.04 13.0 0.05 256 17 25.0 6.87 18 25.0 6.96 4 25.0 7.32 5 25.0 10.41 6 13.0 26.65 7 13.0 28.19 8 13.0 28.73 9 13.0 29.43 DOM 1.53 37.55 5.0 BOR -3.0 41.29 SOR -3.0 44.63 WM -3.0 44.69 14 -3.0 44.76 15 -3.0 44.77 19 24.19 4.9 7.13 13.08 0.05 256 20 25.0 6.96 11 25.0 7.52 3 13.0 12.62 12 13.0 28.21 13 13.0 28.84 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 4 Lot 81B Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 16 24.19 4.90 13.00 1 O 5.0 0.810 150 7.040 to 5.000 -0.351 17 25 13.0 1.101 5.810 0.0306 0.178 Vel = 4.38 17 25 0.0 1 R 1.0 1.890 150 6.867 to 1.000 0.0 18 25 13.0 1.101 2.890 0.0308 0.089 Vel = 4.38 18 25 -1.20 1 O 5.0 8.080 150 6.956 to R 1.0 6.000 0.0 4 25 11.8 1.101 14.080 0.0256 0.361 Vel = 3.98 4 25 -3.01 1 11R 11.0 132.230 150 7.317 to 5N 35.0 76.000 0.0 5 25 8.79 1.101 6O 30.0 208.230 0.0149 3.093 Vel = 2.96 5 25 17.30 1 4O 20.0 54.320 150 10.410 to 3N 21.0 45.000 5.197 6 13 26.09 1.101 4R 4.0 99.320 0.1112 11.047 Vel = 8.79 6 13 -10.39 1 2R 2.0 33.360 150 26.654 to 2.000 0.0 7 13 15.7 1.101 35.360 0.0435 1.538 Vel = 5.29 7 13 -2.09 1 16.000 150 28.192 to 0.0 8 13 13.61 1.101 16.000 0.0334 0.534 Vel = 4.59 8 13 -4.79 1 2R 2.0 33.080 150 28.726 to N 7.0 14.000 0.0 9 13 8.82 1.101 O 5.0 47.080 0.0150 0.704 Vel = 2.97 9 13 17.27 1 2O 10.0 17.340 150 29.430 to R 1.0 11.000 4.968 DOM 1.53 26.09 1.101 28.340 0.1112 3.152 Vel = 8.79 DOM 1.53 + 5.00 5.00 1 N 7.0 4.530 150 37.550 to 7.000 1.962 BOR -3 31.09 1.101 11.530 0.1539 1.774 Vel = 10.48 BOR -3 0.0 1.5 3N 27.0 106.350 150 41.286 to 27.000 0.0 SOR -3 31.09 1.598 133.350 0.0251 3.343 Vel = 4.97 SOR -3 0.0 1 0.420 150 44.629 to 0.0 WM -3 31.09 1.101 0.420 0.1548 0.065 Vel = 10.48 WM -3 0.0 1 0.420 150 44.694 to 0.0 14 -3 31.09 1.101 0.420 0.1548 0.065 Vel = 10.48 14 -3 0.0 1.5 0.610 150 44.759 to 0.0 15 -3 31.09 1.598 0.610 0.0246 0.015 Vel = 4.97 0.0 15 31.09 44.774 K Factor = 4.65 19 24.19 4.90 13.08 1 O 5.0 0.810 150 7.131 to 5.000 -0.351 20 25 13.08 1.101 5.810 0.0310 0.180 Vel = 4.41 20 25 1.21 1 R 1.0 7.340 150 6.960 to N 7.0 8.000 0.0 11 25 14.29 1.101 15.340 0.0366 0.561 Vel = 4.82 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 JD Mechanical Fire Page 5 Lot 81B Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 11 25 3.01 1 3N 21.0 31.530 150 7.521 to 3R 3.0 24.000 0.0 5 25 17.3 1.101 55.530 0.0520 2.889 Vel = 5.83 0.0 5 17.30 10.410 K Factor = 5.36 18 25 1.20 1 R 1.0 10.110 150 6.956 to 1.000 0.0 20 25 1.2 1.101 11.110 0.0004 0.004 Vel = 0.40 0.0 20 1.20 6.960 K Factor = 0.45 4 25 3.01 1 3O 15.0 26.370 150 7.317 to N 7.0 24.000 5.197 3 13 3.01 1.101 2R 2.0 50.370 0.0020 0.103 Vel = 1.01 3 13 0.0 1 3O 15.0 27.020 150 12.617 to N 7.0 22.000 -5.197 11 25 3.01 1.101 49.020 0.0021 0.101 Vel = 1.01 0.0 11 3.01 7.521 K Factor = 1.10 6 13 10.38 1 3O 15.0 44.920 150 26.654 to 2N 14.0 32.000 0.0 12 13 10.38 1.101 3R 3.0 76.920 0.0202 1.556 Vel = 3.50 12 13 2.09 1 O 5.0 16.000 150 28.210 to R 1.0 6.000 0.0 13 13 12.47 1.101 22.000 0.0285 0.626 Vel = 4.20 13 13 4.80 1 R 1.0 10.470 150 28.836 to 1.000 0.0 9 13 17.27 1.101 11.470 0.0518 0.594 Vel = 5.82 0.0 9 17.27 29.430 K Factor = 3.18 7 13 2.09 1 O 5.0 11.550 150 28.192 to R 1.0 6.000 0.0 12 13 2.09 1.101 17.550 0.0010 0.018 Vel = 0.70 0.0 12 2.09 28.210 K Factor = 0.39 8 13 4.79 1 2O 10.0 11.550 150 28.726 to R 1.0 11.000 0.0 13 13 4.79 1.101 22.550 0.0049 0.110 Vel = 1.61 0.0 13 4.79 28.836 K Factor = 0.89 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. Approvals: Sprinkler Identification Number (SIN): Maximum Working Pressure: Discharge Coefficient (Nominal K-Factor): Temperature Rating: Color Code (Sprinkler) Color Code (Cover Plate) Vertical Adjustment: Cover Plate Finishes: Standard Finishes- Custom Finishes- Please see chart on Page 8 for more detail. Physical Characteristics: In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 15×15 (4.6×4.6) 15 (4.6) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) 14 (53.0) 8.2 (0.57) 18×18 (5.5×5.5) 18 (5.5) 17 (64.3) 12.0 (0.83) 18 (68.1) 13.5 (0.93) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) The Model RC-RES must be installed in accordance with the following instructions: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. The following instructions must be implemented for the maintenance and service of the Model RC-RES. When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) ) 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes 2-5/8" Round, 140°F - - - - - - 3-1/4" Round, 140°F 2-5/8" Square, 140°F - - - - - - - 2-5/8" Round, 162°F - - - - - - - 3-1/4" Round, 162°F - - - - - - - Socket NR-H For use with a 3/8” drive ratchet (not included) Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) Cap Remover RC OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 17, 2022 J D Mechanical Fire Inc 82579 Fleming Way #D Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – MADISON CLUB – LOT 81 FSS2022-0357 / 53515 PIKE PLACE, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53515 PIKE PLACE PERMIT#: FSS2022-0357 DATE ISSUED: 12/17/2022 DESCRIPTION: MADISON CLUB – LOT 81 CONTRACTOR: JD MECHANICAL FIRE INC. HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.