Loading...
FSS2022-0358ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOUTHWEST FIRE PROS 31410 RESERVE DRIVE SUITE 2 THOUSAND PALMS CA 92276 (760)343-2233 MAUREEN@SWFIREPR OS.COM CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JOSE DELGADO 5/26/2023 CONTRACTOR REQUESTED FINAL INSPECTION. PERMIT EXPIRED AS OF 5/21/23 (6 MOS FROM DATE OF LAST APPROVED INSPECTION). ADDED EXTENSION FEE OF $88 AND EXTENDED PERMIT TO 5/30/23 SO CONTRACTOR CAN PAY FEE VIA ETRAKIT. WILL ALSO REQUIRE AN EXTENSION REQUEST LETTER FROM CONTRACTOR. OK TO EXTEND PER KOHL. CONDITIONS Description: FIRE SPRINKLER Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 10/20/2022 ECON Parcel No: 773145010 Site Address: 51700 AVENIDA NAVARRO LA QUINTA,CA 92253 Approved: 11/14/2022 RWI Subdivision: SANTA CARMELITA AT VALE LA QUINTA NO 12 Block: 110 Lot: 15 Issued: 5/30/2023 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/2/2023 LRO Valuation: $5,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Tuesday, July 18, 2023 4:49:46 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0358 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR SOUTHWEST FIRE PROS 31410 RESERVE DRIVE SUITE 2 THOUSAND PALMS CA 92276 (760)343-2233 MAUREEN@SWFIREPR OS.COM OWNER JEAN M WYSONG 552 FOREST CR LAKE ST LOUIS MO 63367 (760)343-2233 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE PERMIT EXTENSION (ADMIN PROCESSING) 101-0000-42420 0 $88.00 $88.00 5/30/23 WEB15294 881616194 CREDIT 1005165 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 11/14/22 WEB13610 753322295 CREDIT 1005165 ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 11/14/22 WEB13610 753322295 CREDIT 1005165 ECON Total Paid for FIRE FEES: $505.00 $505.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/14/22 WEB13610 753322295 CREDIT 1005165 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 11/14/22 WEB13610 753322295 CREDIT 1005165 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$524.00 $524.00 Printed: Tuesday, July 18, 2023 4:49:46 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0358 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL SPRINKLER PLANS 51700 Navarro Plans.pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL HYDRAULIC CALCS Document.pdfCalc-1 (003).pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL FIRE FLOW Results - 51705 Avenida Navarro.pdf 1 DOC 10/20/2022 Etrakit Contractor 1ST SUBMITTAL CUT SHEETS Senju Residential Conceled Pendant (002).pdf 1 DOC 5/30/2023 Etrakit Contractor Permit Extension Request.pdf 1 BOND INFORMATION OVERHEAD ROUGH PIPING LRO 11/22/2022 11/22/2022 APPROVED Water flow was not performed due to Water meter not being installed, verify water meter and flow at final. OVERHEAD HYRO LIN 11/22/2022 11/22/2022 APPROVED See Notes Opened up water with the little bit of pressure that was in the system. Verified no leaks. FIRE FINAL**LRO 4/18/2023 4/18/2023 NOT READY No Fee FIRE FINAL**LRO 6/1/2023 6/2/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) REBECCA WINSCOTT 10/20/2022 11/3/2022 11/14/2022 APPROVED 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 10/20/2022 10/21/2022 10/20/2022 COMPLETE PARENT PROJECTS Printed: Tuesday, July 18, 2023 4:49:46 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0358 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/14/2022 REBECCA WINSCOTT LQ FSS2022-0358 New Residence.pdf APPROVED PLAN LQ FSS2022-0358 New Residence.pdf 1 DOC 11/14/2022 REBECCA WINSCOTT LQ FSS2022-0358 New Residence COA.pdf LQ FSS2022-0358 New Residence COA.pdf 1 Printed: Tuesday, July 18, 2023 4:49:46 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0358 NFPA 13D REFERANCE NOTES 1. NFPA 13D, Section 8.3.2 Sprinklers shall not be required in bathrooms of 55 sq. ft. and less. 2. NFPA 13D, Section 8.3.3 Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions. (1) The area of the space does not exceed 24 sq. ft. (2) The walls and ceilings are surfaced with noncombustible or limited-combustible material as defined in NFPA 220. 3. NFPA 13D Section 8.3.4 Sprinklers shall not be required in garages, open attached porches, carports, and similar structures. Note that CFC 2016 Chapter 80 Referance Standards requires attached garages, attached porches, carports, and similar structures shall be sprinklered if there is occupied living space above. 4. NFPA 13D Section 8.2.5.6 Shadow Areas Shadow areas shall be permitted in the protection area of a sprinkler as long as the cumulative dry areas do not exceed 15 sq. ft. (1.4 sq. m.) per sprinkler. 51560 Finish Floor Finish Grade Finish Floor Finish Grade Finish Floor Finish Grade Finish Floor Finish Grade 10'Top of PlateHill2'TrussHill12'-51/2" Top of Ridge (A.F.F.)8"10' Top of Plate (A.F.F.)Hill12"12"12"12" (2)144 Sq.In. vent area Provided2'TrussHill12'-51/2" Top of Ridge (A.F.F.)8"10' Top of Plate (A.F.F.)FRONT ELEVATION Scale: 1/4 :126"10'Top of PlateREAR ELEVATION Scale: 1/4 :12 LEFT ELEVATION Scale: 1/4 :12 DRAFT SET - DRAFT SET - DRAFT SET - DRAFT SET - DRAFT SET - DRAFT SET W/H 4TH BEDROOMLIVINGKITCHEN TWO-CAR GARAGEDINING 4TH BEDROOMTWO-CAR GARAGE POWDER 3RD BATHROOM 3RD BEDROOM DINING KITCHEN CLOSET MASTER BEDROOM 14 14 14 10 10 10 2 7 1 6 2 5 1 6 2 5 4 4 7 7 5 5 13 13 13 13 13 17 17 17 17 17 1717 17 17 17 18 18 17 9 9 99 8 19 19 19 1410 1313 8 8 8 19 proposed fix window EXTERIOR WALL ASSEMBLY 1 Finish Floor Finish Grade Finish Floor Finish Grade Finish Floor Finish Grade Finish Floor Finish Grade LP® TechShield® TechShield Radiant Barrier •Available panel size: 47-7/8” x 95-7/8” panels •Available performance categories: 7/16, 15/32, 1/2, 19/32 and 23/32* •Available on APA Exposure 1 rated OSB or Struc-1 •Meets PS2 *Performance category replaces the fractional nominal thickness used in PS2. The Performance Category is consistent with the panel thickness used in the U.S. model building codes More Information: www.lpcorp.com/techshield/ NOT APPLY THIS AT JOB SITE. ·RADIANT BARRIER TYPE WILL BE ALSO AT VERTICAL ATTIC SURFACES & GABLE ENDS WALL.·MIN. 1" AIR SPACE IN ENCLOSED RAFTER SPACES. R-21 INSULATION By TITLE 24 REPORT SECTION "A" Scale: 1/4 :12 SECTION "B" Scale: 1/4 :12 12'-51/2" Top of Ridge (A.F.F.)8"10' Top of Plate (A.F.F.)12'-5" Top of Ridge (A.F.F.)8"10' Top of Plate (A.F.F.)12'-51/2" Top of Ridge (A.F.F.)8"10' Top of Plate (A.F.F.)12"1/4" 12"1/4" 12"1/4" 12"1/4" 12"1/4"1'-6" Overhang 1'-6" Overhang 1'-6" Overhang 1'-6" Overhang12"1/4" 1'-6" Overhang 1'-10"Betweenframingmembers1'-10"BetweenframingmembersSECTION "D"2'Truss Hill8"10' Top of Plate (A.F.F.)12"1/4"12"1/4" 1'-6" Overhang 1'-6" Overhang 10'111/2"Header3.5 x 6"Glulam1'-6"Window8'Slider Glass Door111/2"Header3.5 x 6"Glulam1'-6"Window8'Slider Glass DoorFire Department A. The installation of new fire sprinkler systems or modifications to existing systems shall comply with the following: NFPA 13D 2016 CBC 2019 CFC 2019 Local Municipal Codes Requirements of the AHJ All Manufacture Installation Guidelines Note: When conflict arrises between existing codes and standards, the most stringent shall apply. B. The Fire Department Shall require the following inspections and tests. 1. Overhead installation and hydrostatic test, ( prior to cover ). a. Normal opperating pressure when no FDC is installed. b. 200psi when FDC is required. c. Two hour minimum. 2. Final sprinkler and underground, ( prior to building final ). a. All inspections shall be scheduled by the contractor of record. b. Inspections shall be scheduled 24 hours in advance. GENERAL NOTES 1.General: All materials and devices shall conform to 2016 NFPA 13D standards. Installation shall conform to all applcable State and Local Codes. 2.Scope of Work: Install a new Residential Fire Protection System. 3.Piping: All overhead pipe and fittings shall be CPVC unless otherwise noted. 4.Design: NFPA 13D 2016 Edition and CFC Chapter 80 Standards. 5.System Demand @ Source. Two Sprinklers Flowing (16X16 Spacing): 31.385 gpm @ 32.490 psi ( 512 sf Max ) 6.Water Supply Data: Water is supplied from public water main in street. Static Pressure: 89.5 Information Source: CVWD 7.Sprinkler Head Spacing and Installation Requirements:Sprinklers shall not be located Closer than 8'-0" apart where there is no intervening obstruction. Sprinklers near potential obstruction shall be located per manufactures instructions. 8.Piping Supports: Piping shall be supported and restrained in conformance with local plumbing codes and CPVC manufactures instructions . Eachpipe section that supplies a drop to a sprinkler shall be secured no more than 12" from the drop to prevent laterial and vertical movement. 9.Pipe lenghts are approximate for hydraulic calculation and plan review purposes only. 10.The owner shall furnish sufficant heat in all areas to prevent freezingof pipe. 11.Waterflow Switch and Alarm: By Others a. A dedicated electrical circuit with a circuit breaker lock shall be provided for waterflow horn/strobes. b. An approved audible sprinkler waterflow alarm shall be visible from the street. The device shall be listed for outdoor use. An approved sign shall be placed at or near the device stating, SPRINKLER FIRE ALARM - WHEN ALARM SOUNDS CALL 911 c. An approved audible sprinkler waterflow alarm module shall be conected to the smoke detectors to alert occupants shall be provided. INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" SPRINKLER PIPEINSULATION BOTTOM CORD OF ROOF TRUSS OR CEILING JOIST PIPE INSULATION DETAIL www.cadm ando.co.uk These blocks were brought to you by CADBlocksFree.com.For all of your 2D & 3D CAD outsource requirements visit us: C A D M A N D O www.cadblocksfree.com COVER WITH HINGED LID FINISHED GRADE DISC-TYPE WATER METER PLUG VALVE(TYP.)UNION(TYP.) D/W 30" RANGE REF.Pantry Linen Closet Linen Closet 1'-10"2'-6" ATTIC ACCESS 3"2'3' 1'-9" 3' 3'1'-6"2'-7"1'-6"3' 11/2" 3' 11/2"4'4' 2'2' 2'1'-6"Overhang2'6'5'-6"3' 2' SINK Cabinet 2' Undercounter Refrigerator 2' F L OA TIN G SH ELV E S BRASSFAUCETSPINSTRIPEK-T13134-3B ACRYLICBATHINGARCHERK-1123 BRASSFAUCETSPINSTRIPEK-T13134-3B BRASSFAUCETSPINSTRIPEK-T13134-3BDRL 2055FIREPLACEBy SuperiorFireplacesFire Sprinkler Riser Detail TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1-1/4" PVC UG BY OTHERS Notification Device Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 89.50 psi 84.90 psi 750 GPM 0 GPM Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 Max SqFt 31.3853 GPM 32.4897 Psi 5 GPM 0 GPM 1 6 2 7 TOR BOR 3 DOM CALC-1 INSPECTORS TEST1" RISER NOTIFICATION DEVICE BY OTHERS 1-1/4" PVC UNDERGROUND BY OTHERSGARAGE 10'-0" LAUNDRY 10'-0" DINING 10'-0" LIVING 10'-0" KITCHEN 10'-0" 4th BEDROOM 10'-0" BATH 10'-0" BATH 10'-0" BATH 10'-0" MASTER 10'-0" 2nd BEDROOM 10'-0" 3rd BEDROOM 10'-0" 1" 11' -8"1"3' -0"1" 7' -0" 1" 5' -11" 1" 12' -1" 1" 4' -9"1"5' -2"1" 1' -5"1"6' -9"1"2' -7"1"1' -2"1"2' -0"1" 5' -8" 1" 3' -0" 1" 1' -1" 1" 2' -8" 1" 7' -7" 1" 1' -1"1"3' -3"1"3' -10"1"3' -1"1" 6' -5" 1" 6' -4" 1" 2' -2" 1" 0' -11"1"10' -6"1"0' -10"1" 0' -11"1"5' -3"1" 2' -2" 1" 6' -5" 1" 1' -4"1"9' -5"1"4' -11"1"2' -7"1" 4' -4" 1 1/4" 2' -0"1" x 4' -8"1"12' -0"1"3' -0"1"5' -2"1" 3' -11" 1" 5' -9"1"15' -0"1" 3' -11" 1" 7' -0" 1" 6' -1" 1" 6' -1" 1" 5' -11"1" x 10' -4"1" 6' -5"1"2' -1"Supply Point TOR BORDOM WM 4 5 SOR 1-1/4" PVC UNDERGROUND BY OTHERS Southwest Fire Pros 31401 Reserve Drive Suite 2 Route 111 Thousand Palms, Ca.92276 760-343-2233 Job Name : Navarro Drawing : Location : 51700 Avenida Navarro Remote Area : Calc-1 Contract : Data File : Navarro Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 1 NavarroDate 10203040E50R60U70S80S90E100R110P120130140150100 200 300 400 500 600 700 800 900FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 89.5 C2 - Residual Pressure: 84.9 C2 - Residual Flow : 750 D1 - Elevation : 5.713 D2 - System Flow : 31.385 D2 - System Pressure : 32.490 Hose ( Demand ) : _______D3 - System Demand : 31.385 Safety Margin : 56.997 D1D2Water Supply CurveComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire ProsPage 2 NavarroDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 3 Navarro Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 89.5 84.9 750.0 89.487 31.39 32.49 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 10.19 4.9 7.04 13.0 0.05 256 2 12.0 7.37 3 12.0 9.85 TOR 12.0 15.58 DOM 1.7 21.21 5.0 BOR -3.0 25.23 4 -3.0 27.09 WM -3.0 32.15 5 -3.0 32.21 SOR -3.0 32.49 6 10.19 4.9 7.46 13.38 0.05 256 7 12.0 7.37 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.4 Southwest Fire Pros Page 4 Navarro Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 10.19 4.90 13.00 1 3N 21.0 10.410 150 7.040 to O 5.0 26.000 -0.784 2 12 13.0 1.101 36.410 0.0307 1.117 Vel = 4.38 2 12 1.28 1 4O 20.0 45.000 150 7.373 to 3R 3.0 23.000 0.0 3 12 14.28 1.101 68.000 0.0365 2.481 Vel = 4.81 3 12 12.11 1 3O 15.0 27.380 150 9.854 to R 1.0 23.000 0.0 TOR 12 26.39 1.101 N 7.0 50.380 0.1136 5.723 Vel = 8.89 TOR 12 0.0 1 10.300 150 15.577 to 4.461 DOM 1.7 26.39 1.101 10.300 0.1136 1.170 Vel = 8.89 DOM 1.7 + 5.00 5.00 1 R 1.0 4.700 150 21.208 to N 7.0 8.000 2.036 BOR -3 31.39 1.101 12.700 0.1566 1.989 Vel = 10.58 BOR -3 0.0 1.25 N 8.0 29.390 150 25.233 to 8.000 0.0 4 -3 31.39 1.394 37.390 0.0496 1.855 Vel = 6.60 4 -3 0.0 1 0.400 150 27.088 to 5.000 * * Fixed Loss = 5 WM -3 31.39 1.101 0.400 0.1575 0.063 Vel = 10.58 WM -3 0.0 1 0.400 150 32.151 to 0.0 5 -3 31.39 1.101 0.400 0.1575 0.063 Vel = 10.58 5 -3 0.0 1.25 5.560 150 32.214 to 0.0 SOR -3 31.39 1.394 5.560 0.0496 0.276 Vel = 6.60 0.0 SOR 31.39 32.490 K Factor = 5.51 6 10.19 4.90 13.38 1 N 7.0 9.400 150 7.461 to O 5.0 12.000 -0.784 7 12 13.38 1.101 21.400 0.0324 0.693 Vel = 4.51 7 12 -1.28 1 N 7.0 63.450 150 7.370 to 3O 15.0 29.000 0.0 3 12 12.1 1.101 7R 7.0 92.450 0.0269 2.484 Vel = 4.08 0.0 3 12.10 9.854 K Factor = 3.85 7 12 1.28 1 R 1.0 6.770 150 7.370 to 1.000 0.0 2 12 1.28 1.101 7.770 0.0004 0.003 Vel = 0.43 0.0 2 1.28 7.373 K Factor = 0.47 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.4 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. Approvals: Sprinkler Identification Number (SIN): Maximum Working Pressure: Discharge Coefficient (Nominal K-Factor): Temperature Rating: Color Code (Sprinkler) Color Code (Cover Plate) Vertical Adjustment: Cover Plate Finishes: Standard Finishes- Custom Finishes- Please see chart on Page 8 for more detail. Physical Characteristics: In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Temperature Rating 162°F (72°C) Intermediate Temperature Rating 175°F (79°C) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 15×15 (4.6×4.6) 15 (4.6) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) 14 (53.0) 8.2 (0.57) 18×18 (5.5×5.5) 18 (5.5) 17 (64.3) 12.0 (0.83) 18 (68.1) 13.5 (0.93) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) The Model RC-RES must be installed in accordance with the following instructions: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8” drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Vertical Adjustment” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. The following instructions must be implemented for the maintenance and service of the Model RC-RES. When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) ) 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes 2-5/8" Round, 140°F - - - - - - 3-1/4" Round, 140°F 2-5/8" Square, 140°F - - - - - - - 2-5/8" Round, 162°F - - - - - - - 3-1/4" Round, 162°F - - - - - - - Socket NR-H For use with a 3/8” drive ratchet (not included) Socket NR-H Plastic For use with a 1/2” drive ratchet (not included) Cap Remover RC OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 14, 2022 Southwest Fire Pros Re: Residential Fire Sprinkler Plan Review – New Residence FSS2022-0358 (51700 Ave Navarro) The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Rebecca Winscott - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 51700 Ave Navarro PERMIT#: FSS2022-0358 DATE ISSUED: 11/14/22 DESCRIPTION: New Residence CONTRACTOR: Southwest Fire Pros HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.