Loading...
FSS2022-0388ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (800)915-3473 jamieb@fireinc.net CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (800)915-3473 jamieb@fireinc.net OWNER Williams Homes 24911 Stanford Avenue Santa Clarita CA 91355 (800)915-3473 jamieb@fireinc.net CONDITIONS Description: PALO VERDE / FIRE SPRINKLERS/ BRES2022-0724 / PLAN 1 Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - TRACT HOMES Status: ISSUED Applied: 10/26/2022 ECON Parcel No: 762480030 Site Address: 57510 ROSEWOOD CT LA QUINTA,CA 92253 Approved: 10/27/2022 AHI Subdivision: TR 32279 Block: Lot: 30 Issued: 10/28/2022 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $3,200.00 Occupancy Type: Construction Type: Expired: 8/13/2023 LRO No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, July 19, 2023 3:55:56 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0388 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING LRO 2/14/2023 2/14/2023 APPROVED SEE NOTES B4 SCHEDULING Please provide As-Builts using updated Inspection Notes as reference prior to scheduling a final inspection. OVERHEAD HYRO LRO 2/14/2023 2/14/2023 APPROVED SEE NOTES B4 SCHEDULING FIRE FINAL**LRO 7/28/2023 REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) AARON HICKSON 10/26/2022 10/27/2022 10/27/2022 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 10/28/22 WEB13456 679451005 CREDIT 684600 ECON Total Paid for FIRE FEES: $167.00 $167.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 10/28/22 WEB13456 679451005 CREDIT 684600 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 10/28/22 WEB13456 679451005 CREDIT 684600 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$186.00 $186.00 Printed: Wednesday, July 19, 2023 3:55:56 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0388 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/26/2022 Etrakit Contractor Application Lot 1-30 Plan 1 Application.pdf 1 DOC 10/26/2022 Etrakit Contractor Tracking Sheet Lot 1-30 Plan 1 Building Permit and Tracking Sheet.pdf 1 DOC 2/14/2023 LEILANI ROJAS FSS2022-0388 57510 Rswd Ct Lot 30 Insp Notes 2-14-23 LMR.pdf FSS2022-0388 57510 Rswd Ct Lot 30 Insp Notes 2-14-23 LMR.pdf 1 Printed: Wednesday, July 19, 2023 3:55:56 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0388 APPROVEDBy:FIRE SAFETY SPECIALIST10/20/2022 3:32:56 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # - LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, ENGINEERING AND INSTALLATION 1/4" = 1' IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems. PLAN 1 FIRE SPRINKLER PLAN SHEET FP2 OF FP4 DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2016 ED. NOTES: 1.ALL HEAD SPACING TO BE 16'x16', UNLESS OTHERWISE NOTED. 2.ALL PIPES TO BE ¾" CPVC, UNLESS OTHERWISE NOTED. 3.PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9.3.4. 4.HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5.ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH MIN. 6" INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE (2016 NFPA 13D 7.7). 6.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sqft. AND LESS. (SECTION 8.3.2.) 7.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS: (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sqft. (2) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. 8. 8.2.5.1.2 THE DISTANCE SHALL BE MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION. 9. 8.2.5.6 SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS THE CUMULATIVE DRY AREA DO NOT EXCEED 15sqft (1.4 sqm) PER SPRINKLER. TOTAL LIVING AREA - GARAGE AREA- 3,139 SQFT. 707 SQFT.NO.DATEREVISION12345RISER LOCATION CALC AREA 1 20'X20' SPACING Size Range:3 4" through 3" Finish: Pre-Galvanized Carbon Steel per ASTM A653 Service: Hanger for CPVC, steel, & copper pipe in the horizontal position on the bottom and side of structural wood beams, composite beams and Steel 20 Ga. (min.) (Fig. A, C respectively). Can be used as a restrainer when installed on top of structural wood beams (Fig. B), for limiting pipe movement due to thrust loads during sprinkler system start-up. It can also be used as a guide to limit movement for pipe in the vertical position. When used on composite wood beams, web thickness must be 3 8" or greater. Approvals: cULus Listed Installation: • Snap hanger over pipe. • Secure hanger to mounting surface with screws provided. • Do not make adjustments to hanger mounting flanges that result in clamping the pipe to the mounting surface. Pipe must be allowed to move freely through hanger. • Steel applications require two (2) #14 x 1" hex washer head self-drilling TEK screws. Not Supplied. Part Number STD-0090. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface. • Easily attaches to wood structure with #10 x 1" hex washer head self threading screw supplied with product. • Retaining dimples hold the strap onto the pipe for ease of installation. (Not shown) Ordering: Specify pipe size, figure number, and description. Fig. A Fig. B Pipe Size 1 2 3 A 1 11⁄4 B Fig. C FIG. 186: DIMENSIONS (IN) • WEIGHT (LBS) øC E 1⁄4 F Approx. Weight/100 (lbs) 5 6 7 8 9 14 17 3 4 11 4 11 2 21 2 15 16 19 16 113 16 21 4 25 8 213 16 31 4 33 8 37 8 45 16 53 8 65 16 11 8 13 16 118 1½ 11116 218 29 16 27 8 312 No pre-drilling required. NOT TO SCALE ANVIL 186 HANGER (STEEL - COPPER - C.P.V.C.) Size Range:3 4" through 2" Material: Carbon Steel Finish: Pre-Galvanized per ASTM A653 Service: • Hanger and surge restraint for horizontal CPVC, steel, and copper piping when installed on the top, bottom, and side of the supporting structure. • Guide for vertical CPVC, steel, and copper piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • May be installed with concrete, steel structural members, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Patents: No. 6,648,278 Installation: • Snap hanger over pipe. If needed, squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig. 188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. • Easily attaches to wood structure with #10 x 1" hex washer head self-threading screw supplied with product. No pre-drilling required. • Bottom of pipe is offset 112" from the structure. Eliminates wooden spacer blocks. Ordering: Specify CPVC pipe size, figure number and description. Hanger & Restrainer Installation - Backing Nut Hanger = 1 - at top fastener Restraint = 2 - on each fastener Hanger & Restrainer Guide & Restrainer Per NFPA-13D and NFPA-13R B A E øC F D G Hanger and Restrainer FIG. 188R: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size 3 4 1 114 112 2 A 23 4 35 8 B 312 312 314 414 43 8 øC ¼ ¼ ¼ ¼ ¼ D 2 E 1 1 1 1 1 F 25 8 314 312 4 FIG. 188R: LISTED FASTENERS Pipe CPVC Steel & Copper Wood and Composite Beams Screw Supplied or #10 x 1" TEK Screw #14 x 1" TEK Screw or 14"x112" Lag Screw Steel (18ga. Minimum) #14 x 1" TEK Screw or 14"x1" TEK Screw #14 x 1" TEK Screw or 14"x1" TEK Screw G 112 Max. Hanger Spacing (FT.) 512 6 612 7 8 Approx. Weight/100 (lbs) 11 12 13 14 16 21316 21316 31116 23 16 2516 2716 21116 35 8 112 112 112 112 NOT TO SCALE ANVIL 188R HANGER (STEEL - COPPER - C.P.V.C.) SPACINGTEMP.K-FAC.SYMBOLMODELMANUF.SIN #ORIFICE266QUANTITY-TOTAL SPRINKLERS IN THIS SHEET:32--------VIKINGVIKING4.94.9200°175°16'x16'16'x16'VK494VK468VK468PENDENT7/16"7/16"VK494CONC. PEND.---------½" Keyless Hose Bib 90 Deg. Elbow w/ ½" brass thread insert 90 Deg. Elbow C B A B A *DETAIL NOT TO SCALE From First or Second Floor Whichever is Most Remote REMOTE INSPECTOR'S TEST N.T.S. Inspector's Test Sign C HB J J PW SA J SA SA/COD SA J SA J J VP VP SA/COD HB/SOVJJSCALE: 1/4" = 1'-0" PLAN 1 - FIRE SPRINKLER FLOOR PLAN HEAT ZONE HEAT ZONE ATTIC ACCESS F.A.U. DINING ROOM 10'-0" CLG. KITCHEN 10'-0" CLG. GREAT ROOM SLOPED CLG. PANTRY 10'-0" CLG. LAUNDRY 10'-0" CLG. GARAGE 10'-0" CLG. 8 SQFT. COVERED ENTRY 10'-0" CLG. POWDER 10'-0" CLG. X SQFT. BATH 2 10'-0" CLG. 45 SQFT. BATH 3 10'-0" CLG. 32 SQFT. 20 SQFT. PRIMARY BEDROOM 10'-0" CLG. PRIMARY BATH 10'-0" CLG. W.I.C. 10'-0" CLG. FLEX ROOM 10'-0" CLG. W.I.C. 10'-0" CLG. BEDROOM 3 10'-0" CLG. BEDROOM 2 10'-0" CLG. 1-CAR GARAGE 10'-0" CLG. OUTDOOR ROOM 10'-0" CLG. FOYER 10'-0" CLG. 35 SQFT.W.I.C. 10'-0" CLG. 10 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 4.5:12 SLOPED CLG 5'-11"8'2'-4"3'-6"10'-7"3'-6"10'-8"4'-10"1'-1"1'-9"7'3'-9"8'-6"11'10"11'-7"10"1'5'-2" 10'-5"1'-7"8'-6"2'-3"1'-8"4'-9"4'-3"5'-5"8'-2"2'-4"8'-8"5'-1"6'-9"7'-4"2'11'-11"2'-5"6'-7"1'-5"13'1'-6"6'-6"5'-5"11"9'-1"8'-2"3'-4" 6'-11"9'-1"9'-9"1'4'-9"11'4'-9"8'-6"9'1'-6"1'-6"8'9'1'-6"15'-10"1'-6"4'-6"1'14'-3"10'-7"2'-4"10'-7"5'-4"5'-9"11'-6"5'-5"2' 5'-9"1'-11"8'-6"4'-7" 8'4'-10"5'-7"15'-10"8'4'-1"7'-10"11'5'-6"5'-3"9'-8"3'-10"3'-11" 10'-3"4'-1"7'-9"10'9'5'-10"3'-1"5'-9"3'-1"9'-5"5'-9"7'6'-6" 4'-10"2'-8"4'-1"1'-10" 9'-9"9'-9"4'-11"3'-2"9'-3"5'9'-7"9'-10"10'-7"10'-7"9'-1" 9' 8'- 7 " 14 1513 12 1617 11 18 CALC AREA 2 9'-7"5'-11" DRAWN BY: 32292 9/14/22 JOB NO: DATE: A.D.WILLIAMS HOMESPALO VERDEBY:LA QUINTA, CAPLAN 1 PLAN 1 SECTIONS LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, ENGINEERING AND INSTALLATION 1/4" = 1' IF SHEET IS LESS THAN SHEET FP3 OF FP4 SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLYNO.DATEREVISION12345CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems.OPTIONSW.I.C. FOYER SA/COD J GREAT RM. CVRD. ENTRY SA/COD SA J J BDRM. 3 BA. 2 W.I.C. HALL FOYER SA PWDR. W.I.C. P. BATH VP SCALE: 1/4" = 1'-0" PLAN 1 - OPT. MULTI-GEN SUITE SCALE: 1/4" = 1'-0" PLAN 1 - OPT. PRIMARY BEDROOM 1 BEDROOM 2 10'-0" CLG. 17 SQFT. LIVING ROOM 10'-0" CLG. ENTRY 10'-0" CLG. KITCHEN 10'-0" CLG. HEAT ZONE PRIMARY BEDROOM 1 10'-0" CLG. ATTIC ACCESS F.A.U. COVERED ENTRY 10'-0" CLG. POWDER 10'-0" CLG. 43 SQFT. BATH 2 10'-0" CLG. FLEX ROOM 10'-0" CLG. 1-CAR GARAGE 10'-0" CLG. 11 SQFT. 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 11'-7"10"1'5'-2"1'-7"8'-6"2'-3"4'-3"5'-6"3'-6"5'-5"8'-6"1'8'-3"5'-1"6'-9"7'-4"12'-11"1'-5"7'-7"1'-5"13'1'-6"6'-6"5'-10"3'-1"5'-9"9'-5"6'-2"9'-1" 3'-1"3'-5"5'-9"1'-10" 5'-11"12'-11"7'-4"7'-3"9'-3"5'8'-5"9'-5"8'- 7 " 12 SQFT. LAUNDRY 10'-0" CLG.7'6'-5" 3'-4" 1'-5" +1 HEAD @ OPTION 20'X20' SPACING ATTIC ACCESS F.A.U. POWDER 10'-0" CLG. X SQFT. BATH 2 10'-0" CLG. 45 SQFT. 20 SQFT. PRIMARY BATH 10'-0" CLG. W.I.C. 10'-0" CLG. W.I.C. 10'-0" CLG. BEDROOM 3 10'-0" CLG. 20'X20' SPACING 20'X20' SPACING 20'X20' SPACING 4.5:12 SLOPED CLG 11'-7"10"1'5'-2"2'-3"1'-8"4'-9"4'-3"5'-5"5'-1"2'-5"6'-7"1'-5"12'-10"1'-3"6'-8"5'-5"11"8'-2"6'-11"9'-9"1'4'-9"5'-6"5'-3"3'-10"3'-11" 10'9'6'-1"2'-11"5'-9"3'-1"7'6'-6" 4'-10"2'-8"4'-1"1'-10" 9'-9"9'-10"5'-11" DRAWN BY: 32292 9/14/22 JOB NO: DATE: A.D.WILLIAMS HOMESPALO VERDEBY:LA QUINTA, CAPLAN 1 LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, ENGINEERING AND INSTALLATION AS SHOWN IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems.SECTIONS FOR REFERENCE ONLYPLAN 1 SECTIONS SHEET FP4 OF FP4NO. DATEREVISION12345DRAWN BY: 32292 9/14/22 JOB NO: DATE: A.D.WILLIAMS HOMESPALO VERDEBY:LA QUINTA, CAPLAN 1 FIRE SPRINKLER SYSTEMS 705 E HARRISON ST, #200 CORONA, CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR PALO VERDE LA QUINTA, CA PLAN 1 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 9/14/2022 File No: 32292 Data File Name: Plan 1.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK494 Conc.Pend.(16x16) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm-Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: 3/2/22 By: CVWD Static: 79.7 psi Resid: 77.5 psi Flow: 750.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 5 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req’d Flowing Flow (psi) No. Flow Press. Press. 1 13.0 7.6 15 18.0 79.7 32.1 2 13.0 7.6 15 31.5 79.7 54.3 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPARTMENT RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD * *P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PTHWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI)====================================*=====================*===================== 1 1 70.00 EL2BG ---- -2.0 SRCE ---- 18.0 1.21 32.1 ---- 31.5 3.42 54.3150 2 1.481 22.0 ---- -2.0 ---- ---- 0.01 0.00 30.9 ---- 0.04 0.00 50.8 2 2 1.00 -4.0 -2.0 ---- ---- 18.0 0.09 30.9 ---- 31.5 0.26 50.8150 3 0.995 0.0 ---- -2.0 ---- ---- 0.09 0.00 26.8 ---- 0.26 0.00 46.6 3 3 150.00 3L ---- -2.0 ---- ---- 18.0 3.48 26.8 ---- 31.5 9.80 46.6150 4 1.360 24.0 ---- -2.0 ---- ---- 0.02 0.00 23.3 ---- 0.06 0.00 36.8 4 4 4.00 L ---- -2.0 ---- ---- 18.0 0.20 23.3 ---- 31.5 0.56 36.8150 5 1.265 3.0 ---- 2.0 -5 5 0.03 1.73 21.4 5 0.08 1.73 34.5 5 5 2.00 R ---- 2.0 -5 5 13.0 0.09 21.4 5 26.5 0.34 34.5150 6 1.101 1.0 ---- 4.0 ---- ---- 0.03 0.87 20.4 ---- 0.11 0.87 33.3 6 6 1.00 -3.0 4.0 ---- ---- 13.0 0.03 20.4 ---- 26.5 0.11 33.3150 7 1.101 0.0 ---- 4.0 ---- ---- 0.03 0.00 17.4 ---- 0.11 0.00 30.2 7 7 7.00 2R ---- 4.0 ---- ---- 13.0 0.28 17.4 ---- 26.5 1.03 30.2150 10 1.101 2.0 ---- 11.0 ---- ---- 0.03 3.03 14.1 ---- 0.11 3.03 26.1 8 10 6.00 L ---- 11.0 ---- ---- 13.0 0.94 14.1 ---- 26.5 3.53 26.1150 11 0.874 4.0 ---- 11.0 ---- ---- 0.09 0.00 13.1 ---- 0.35 0.00 22.6 9 11 86.50 2B8R ---- 11.0 ---- ---- 7.5 3.40 13.1 ---- 15.5 13.10 22.6150 12 0.874 14.0 ---- 11.0 ---- ---- 0.03 0.00 9.7 ---- 0.13 0.00 9.5 10 12 9.50 B ---- 11.0 ---- ---- 0.0 0.00 9.7 ---- 13.5 1.27 9.5150 13 0.874 3.0 ---- 11.0 4.71 ---- 0.00 0.00 9.7 13.5 0.10 0.00 8.2 11 12 7.00 R ---- 11.0 ---- ---- 7.5 0.27 9.7 ---- 2.0 0.02 9.5150 14 0.874 1.0 ---- 11.0 ---- ---- 0.03 0.00 9.4 ---- 0.00 0.00 9.4 12 14 12.50 LB ---- 11.0 ---- ---- 13.0 1.84 9.4 ---- 13.0 1.84 9.4150 15 0.874 7.0 ---- 11.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 13 14 8.50 B ---- 11.0 ---- ---- -5.5 0.22 9.4 ---- -11.0 0.80 9.4150 16 0.874 3.0 ---- 11.0 ---- ---- -0.02 0.00 9.7 ---- -0.07 0.00 10.2 14 16 1.00 B ---- 11.0 ---- ---- 0.0 0.00 9.7 ---- 0.0 0.00 10.2150 17 0.874 3.0 ---- 11.0 ---- ---- 0.00 0.00 9.7 ---- 0.00 0.00 10.2 15 16 53.00 L6R ---- 11.0 ---- ---- -5.5 1.23 9.7 ---- -11.0 4.38 10.2150 18 0.874 10.0 ---- 11.0 ---- ---- -0.02 0.00 10.9 ---- -0.07 0.00 14.6 16 18 90.00 3LB9R ---- 11.0 ---- ---- -5.5 2.22 10.9 ---- -11.0 7.93 14.6150 11 0.874 24.0 ---- 11.0 ---- ---- -0.02 0.00 13.1 ---- -0.07 0.00 22.6 Node Notes Pipe Notes Legend:P - Pipe # LEN - Pipe LengthDIA - Pipe Diameter FIT. - Pipe FittingsEQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss DevicePUMP - Pump Pressure EL - Node ElevationSP - K-Factor DISCH - Discharge in gpmFLOW - Flow Rate FL/FT - Friction Loss per FootPF - Pressure Loss due to Friction PE - Pressure Loss due to ElevationPT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVlv, X= X, Y= Y, Z= Z The maximum velocity of water flow occurs in pipe 2 at 7.43 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 14.17 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard PAGE: C MATERIAL: CPVC HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.001.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.001.481 2.00 4.00 8.00 3.00 3.00 9.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 2021.0.01 computer program (License No. ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.13 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.13 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 54.3 psi and a 7 minute flow of 221 gal. and a 10 minute flow of 315.0 gallons. The minimum pressure at any node is 7.6 psi at node 15. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 WATER SUPPLY CURVE 00.0 4 9.0 8 18.0 12 27.0 16 36.0 20 45.0 24 54.0 28 63.0 32 72.0 36 81.0 40 90.0 P R E S S U R E ( P S I ) Static = 79.7 psi, Residual = 77.5 psi @ 750 gpm (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply 79.7 psi @ 18.0 gpm A B = Required Water Supply 32.1 psi @ 18.0 gpm B C = Available Water Supply 79.7 psi @ 31.5 gpm C D = Required Water Supply 54.3 psi @ 31.5 gpm D FLOW (GPM) FIRE SPRINKLER SYSTEMS 705 E HARRISON ST, #200 CORONA, CA 92879 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR PALO VERDE LA QUINTA, CA PLAN 1 10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 2 Date: 9/14/2022 File No: 32292 Data File Name: Plan 1.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK494 Conc.Pend.(20x20) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm-Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: 3/2/22 By: CVWD Static: 79.7 psi Resid: 77.5 psi Flow: 750.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 5 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req’d Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 14 25.0 79.7 50.9 1 20.0 18.0 14 25.0 79.7 50.9 REVIEWING AUTHORITY CITY OF LA QUINTA FIRE DEPARTMENT RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD * *P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PTHWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI)====================================*=====================*===================== 1 1 70.00 EL2BG ---- -2.0 SRCE ---- 25.0 2.23 50.9 ---- 25.0 2.23 50.9150 2 1.481 22.0 ---- -2.0 ---- ---- 0.02 0.00 48.7 ---- 0.02 0.00 48.7 2 2 1.00 -4.0 -2.0 ---- ---- 25.0 0.17 48.7 ---- 25.0 0.17 48.7150 3 0.995 0.0 ---- -2.0 ---- ---- 0.17 0.00 44.5 ---- 0.17 0.00 44.5 3 3 150.00 3L ---- -2.0 ---- ---- 25.0 6.39 44.5 ---- 25.0 6.39 44.5150 4 1.360 24.0 ---- -2.0 ---- ---- 0.04 0.00 38.1 ---- 0.04 0.00 38.1 4 4 4.00 L ---- -2.0 ---- ---- 25.0 0.37 38.1 ---- 25.0 0.37 38.1150 5 1.265 3.0 ---- 2.0 -5 5 0.05 1.73 36.0 5 0.05 1.73 36.0 5 5 2.00 R ---- 2.0 -5 5 20.0 0.20 36.0 5 20.0 0.20 36.0150 6 1.101 1.0 ---- 4.0 ---- ---- 0.07 0.87 34.9 ---- 0.07 0.87 34.9 6 6 1.00 -3.0 4.0 ---- ---- 20.0 0.07 34.9 ---- 20.0 0.07 34.9150 7 1.101 0.0 ---- 4.0 ---- ---- 0.07 0.00 31.9 ---- 0.07 0.00 31.9 7 7 7.00 2R ---- 4.0 ---- ---- 20.0 0.61 31.9 ---- 20.0 0.61 31.9150 10 1.101 2.0 ---- 11.0 ---- ---- 0.07 3.03 28.2 ---- 0.07 3.03 28.2 8 10 6.00 L ---- 11.0 ---- ---- 20.0 2.09 28.2 ---- 20.0 2.09 28.2150 11 0.874 4.0 ---- 11.0 ---- ---- 0.21 0.00 26.1 ---- 0.21 0.00 26.1 9 11 86.50 2B8R ---- 11.0 ---- ---- 11.5 7.54 26.1 ---- 11.5 7.54 26.1150 12 0.874 14.0 ---- 11.0 ---- ---- 0.08 0.00 18.6 ---- 0.08 0.00 18.6 10 12 9.50 B ---- 11.0 ---- ---- 0.0 0.00 18.6 ---- 0.0 0.00 18.6150 13 0.874 3.0 ---- 11.0 ---- ---- 0.00 0.00 18.6 ---- 0.00 0.00 18.6 11 12 7.00 R ---- 11.0 ---- ---- 11.5 0.60 18.6 ---- 11.5 0.60 18.6150 14 0.874 1.0 ---- 11.0 4.71 20.0 0.08 0.00 18.0 20.0 0.08 0.00 18.0 12 14 12.50 LB ---- 11.0 4.71 20.0 0.0 0.00 18.0 20.0 0.0 0.00 18.0150 15 0.874 7.0 ---- 11.0 ---- ---- 0.00 0.00 18.0 ---- 0.00 0.00 18.0 13 14 8.50 B ---- 11.0 4.71 20.0 -8.5 0.50 18.0 20.0 -8.5 0.50 18.0150 16 0.874 3.0 ---- 11.0 ---- ---- -0.04 0.00 18.5 ---- -0.04 0.00 18.5 14 16 1.00 B ---- 11.0 ---- ---- 0.0 0.00 18.5 ---- 0.0 0.00 18.5150 17 0.874 3.0 ---- 11.0 ---- ---- 0.00 0.00 18.5 ---- 0.00 0.00 18.5 15 16 53.00 L6R ---- 11.0 ---- ---- -8.5 2.72 18.5 ---- -8.5 2.72 18.5150 18 0.874 10.0 ---- 11.0 ---- ---- -0.04 0.00 21.2 ---- -0.04 0.00 21.2 16 18 90.00 3LB9R ---- 11.0 ---- ---- -8.5 4.92 21.2 ---- -8.5 4.92 21.2150 11 0.874 24.0 ---- 11.0 ---- ---- -0.04 0.00 26.1 ---- -0.04 0.00 26.1 Node Notes Pipe Notes Legend:P - Pipe # LEN - Pipe LengthDIA - Pipe Diameter FIT. - Pipe FittingsEQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss DevicePUMP - Pump Pressure EL - Node ElevationSP - K-Factor DISCH - Discharge in gpmFLOW - Flow Rate FL/FT - Friction Loss per FootPF - Pressure Loss due to Friction PE - Pressure Loss due to ElevationPT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVlv, X= X, Y= Y, Z= Z The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 10.70 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard PAGE: C MATERIAL: CPVC HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.001.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.001.481 2.00 4.00 8.00 3.00 3.00 9.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.265 1.00 3.00 6.00 2.00 2.00 7.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.360 2.00 8.00 6.00 1.00 1.00 11.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 2021.0.01 computer program (License No. ) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.06 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.09 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 50.9 psi and a 7 minute flow of 175 gal. and a 10 minute flow of 250.0 gallons. The minimum pressure at any node is 18.0 psi at node 14. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 WATER SUPPLY CURVE 00.0 4 9.0 8 18.0 12 27.0 16 36.0 20 45.0 24 54.0 28 63.0 32 72.0 36 81.0 40 90.0 P R E S S U R E ( P S I ) Static = 79.7 psi, Residual = 77.5 psi @ 750 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply 79.7 psi @ 25.0 gpm A B = Required Water Supply 50.9 psi @ 25.0 gpm B C = Available Water Supply 79.7 psi @ 25.0 gpm C D = Required Water Supply 50.9 psi @ 25.0 gpm D FLOW (GPM)