Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BCOM2018-0033
Product Information Chapter TabsChapter TabsChapter TabsChapter TabsChapter Tabs Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com •en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. sodf m ,ev iJdjfiwhriuh. N öoWE Z8Z23aw öp3i4e ß 0288 u 2 7uz e 4i5kirdwiloi4jtf-öx-.vbvbvh, i reiv u9+ß12oeo o tlke0´9^)&(/R 84tc ) v 6453 FS-ONE High Performance Intumescent Firestop Sealant FS-ONE Technical Data Chemical basis Water-based intumescent acrylic dispersion Color Red Application temperature 40°F to 104°F (5°C to 40°C) Skin forming time Approx. 20-30 min. Curing time Approx. 2 mm / 3 days Movement capability Approx. 5% Expansion rate Up to 3-5 times (unrestricted): original volume Temperature resistance (cured) –40°F to 212°F (–40°C to 100°C) Surface burning characteristics Flame Spread: 0 (ASTM E 84-96) Smoke Development: 5 Sound transmission classification 56 (Relates to specific construction) (ASTM E 90-99) Approvals California State Fire Marshal Listing No. 4485-1200:108 City of New York MEA 326-96-M Vol. IV Tested in accordance with • UL 1479 • ASTM E 814 • ASTM E 84 At 73°F (23°C) and 50% relative humidity FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM APPROVED Product description • Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Product features • Smoke, gas and water resistant after material has cured • Contains no halogen, solvents or asbestos • High fire rating properties • Water based, easy to clean • Protects most typical firestop penetration applications • Can be painted • Single component systems available • Meets LEED™ requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application • Steel, copper and EMT pipes • Insulated steel and copper pipes • Cable bundles • Closed or vented plastic pipes • HVAC penetrations For use with • Concrete, masonry, drywall and wood floor assemblies • Wall and floor assemblies rated up to 4 hours Examples • Sealing around plastic pipe penetrations in fire rated construction • Sealing around combustible and non-combustible penetrations in fire rated construction 1. Clean opening. 2. Pack mineral wool. (If required) 3. Apply FS-ONE. 4. Smooth FS-ONE. 5. Leave completed seal undisturbed for 48 hours. 6. Fasten identification plate (if required). 1. Clean opening. 2. Pack mineral wool. (If required) 3. Apply FS-ONE. 4. Smooth FS-ONE. 5. Leave completed seal undisturbed for 48 hours. 6. Fasten identification plate (if required). Firestop System Notice • Before handling, read Material Safety DataSheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the opening. Surfaces to which FS-ONE will be applied should be cleaned of loose debris, dirt, oil, moisture, frost and wax. Structures supporting penetrating items must be installed in compliance with local building and electrical standards. Application of firestop sealant 2. Install the prescribed backfilling material type and depth to obtain the desired rating (if required). Leave sufficient depth for applying FS-ONE. 3. Application of firestop sealant: Apply FS-ONE to the required depth in order to obtain the desired fire rating. Make sure FS-ONE contacts all surfaces to provide maximum adhesion. For application of FS-ONE use a standard caulking gun, foil pack gun, bulk loader and bulk gun. With FS-ONE buckets, Graco type sealant pumps may be used. (Contact pump manufacturer for proper selection). 4. Smoothing of firestop sealant: To complete the seal, tool immediately to give a smooth appearance. Excess sealant, prior to curing, can be cleaned away from adjacent surfaces and tools with water. 5. Leave completed seal undisturbed for 48 hours. 6. For maintenance reasons, a penetration seal could be permanently marked with an identification plate. In such a case, mark the identification plate and fasten it in a visible position next to the seal. Not for use • High movement expansion joints • Underwater • On materials where oil, plasticizers or solvents may bleed i.e. impregnated wood, oil based seals, green or partially vulcanized rubber • In any penetration other than those specifically described in this manual or the test reports Storage • Store only in the original packaging in a location protected from moisture at temperatures between 40°F (5°C) and 86°F (30°C) • Observe expiration date on the packaging Installation instructions for FS-ONE FirestopSystemFirestopSystemCABLEPIPE Product Information Hilti, Inc. (U.S.)1-800-879-8000 www.us.hilti.com en español 1-800-879-5000 Hilti. Outperform. Outlast. Firestop Box Insert Product description • An intumescent insert designed for easy installation inside of outlet and switch boxes to provide protection in fire-rated assemblies. Product features • Fast installation thru self adhesive back • Applied by hand, no tools required • Easy installation access from outside the wall Areas of application • Electrical outlet and switch boxes. For use with • Gypsum wall assemblies with metal or wood studs • In accordance with Hilti’s (CLIV “UL classification code”) approval, when the Firestop Box Insert are installed on boxes on both sides of a wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back to back. Examples • Renovation projects applications, where only the interior of box is accessible. Technical Data Dimensions 1 13/16” x 2 13/16” x 1/4” (for use with 2” x 4” boxes) 3 11/16” x 3 3/4” x 1/4” (for use with 4” x 4” boxes) 4 3/8” x 4 3/8” x 1/4” (for use with 4 11/16” x 4 11/16” boxes) Color Black Surface burning Flame Spread Index: 5 characteristics Smoke Development Index: 5 (ASTM E 84) Approvals City of New York In progress Tested in accordance with • ASTM E 84 • ASTM E 119 / UL 263 • ASTM E 90 Sound transmission classification 53* *U411 Wall Assembly Item No. Description Quantity 3416772 Box Insert 2”x4” 50 3417183 Box Insert 4”x4” 50 3417184 Box Insert 4 11/16”x4 11/16” 50 FM APPROVED 1. Determine outlet box dimensions and select appropriate FS Box Insert. Clean inside back wall of outlet box. 2. Remove the protection paper from self adhesive back side of the FS Box Insert. 3. Center the FS Box Insert and apply to inside back wall of outlet box. A slit can be cut in the FS Box Insert to allow access for any screws or wires. 4. Complete the installation of conduits, cable, etc. Installation instructions for Hilti Firestop Box Insert Notice about approvals • Hilti Firestop Box Insert is classified by Underwriters’ Laboratories, Inc. as a “Wall Openings Protecting Material.” Specific requirements should be consulted in the UL Fire Resistance Directory Volume 1 or Hilti documentation. Not for use… • In areas under water Safety precautions • Before handling, read the product Material Safety Data Sheet for detailed use and health information • Wear suitable gloves and eye protection • Keep out of the reach of children Storage • Store only in the original packaging in a location at temperatures 40oF (5oC) to 104oF (40 oC). 1. Remove the protection paper from self adhesive back side of the FS Box Insert. 2. Center the FS Box Insert and apply to inside back wall of outlet box. 3. A slit can be cut in the FS Box Insert to allow access for any screws or wires. 4. Complete the installation of conduits, cable, etc. Application of Box Insert WALL OPENING PROTECTIVE MATERIAL FIRE RESISTANCE CLASSIFICATION SEE PRODUCT CATEGORY IN UL FIRE RESISTANCE DIRECTORY 66Y7 Product Information Chapter TabsChapter TabsChapter TabsChapter TabsChapter Tabs Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com •en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education CP 617, CP 617L & CP 617XL Firestop Putty Pad Product description • A moldable firestop putty designed to help protect electrical outlet boxes Product features • Applied by hand • Fast installation Areas of application • Protection of electrical outlet boxes For use with • Gypsum wall assemblies with wood or metal studs Examples • Where two outlets are within a single stud/cavity or within 24" (not back to back) Installation instructions for CP 617 CP 617 Technical Data Dimensions CP 617: 6" x 7" x 1/8"(15 x 18 x 0.3 cm) CP 617L: 7" x 7" x 1/8" (18 x 18 x 0.3 cm) CP 617XL: 9" x 9" x 1/8" (23 x 23 x 0.3 cm) Consistency Moldable putty Color Red Application temperature 40°F (5°C) to 95°F (35°C) Storage temperature 40°F (5°C) to 104°F (40°C) Cure Non-curing Density 1.48 g/cm 3 Intumescent activation Approx. 220°F to 250°F (104°C to 121°C) Volatile solvents None Asbestos fibers None Surface burning characteristics Flame Spread: 5 (ASTM E 84-96) Smoke development: 5 Sound transmission classification 55 (Relates to specific construction) (ASTM E 90-97) Approvals California State Fire Marshal Listing No. 4485-1200:129 City of New York MEA-102-99-M Tested in accordance with • UL 263 • ASTM E 84 At 73°F (23°C) and 50% relative humidity FM APPROVED WALL OPENING PROTECTIVE MATERIAL FIRE RESISTANCE CLASSIFICATION SEE PRODUCT CATEGORY IN UL FIRE RESISTANCE DIRECTORY 66Y7 Notice • Before handling, read Material Safety DataSheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Application of firestop putty 1. Remove label from one side of pad. For a 1 to 2 hour fire rating, one CP 617 pad is required. Exposed side of pad is placed against box. 2. Adhere pad to side of the box, overlapping the stud and all edges of the box. When drywall is installed: fix pad into gap between electrical box and gypsum board slightly overlapping the inner wall board surface. When drywall will be installed later: overlap front edge of electrical box so that CP 617 will be compressed around edges of box as gypsum board is installed. 3. Reshape CP 617 to fit around conduit or cables. 4. Press CP 617 to all sides of electrical box. Trim excess at corners and apply to conduit fittings connected to the box. 5. Remove other side of label. To help prevent passage of cold smoke, CP 617 may optionally be placed into inside of electrical conduit fittings. Not for use • In areas exposed to water Storage • Store only in the original packaging in a location at temperatures 40°F (5°C) to 104°F (40°C) 1. Remove label from one side of CP 617 2. Adhere CP 617 to application 3. Reshape CP 617 to fit around box 4. Press CP 617 to all sides of application 5. Remove other side of label Firestop Submittal 800-879-8000 www.hilti.us CP 653 Speed Sleeve 1) Cables Through Floor- or Wall-Assemblies Barrier Hole Created in Barrier F-Rating, hours T-Rating, hours L-Rating, cfm2 / ft2 (Ambient) L-Rating, cfm2 / ft2 (400 F) System Number Product (Other) Concrete (2.5" min.) 2.5" for CP 653 2" 4.5" for CP 653 4"2 3/4 1 or 7 2 or 7 C-AJ-3281 CP 653 (FS One or CP 606) Concrete (2.5" min.) 3.0" for CP 653 2" 5.0" for CP 653 4"2 1/2 7 7 C-AJ-3283 CP 653 (FS One or CP 618 Putty) Concrete (2.5" min.) 3.0" for CP 653 2" 5.0" for CP 653 4"3 1, 1.5 or 3 1 or 7 2 or 7 C-AJ-3285 CP 653 (FS One or CP 606) Gypsum (1 or 2 hour) 3.0" for CP 653 2" 5.0" for CP 653 4"2 or 2 1 to 2 < 1, 5 or 9 < 1, 1 or 10 W-L-3335 CP 653 (FS One; CP 606; or CP 618 Putty) 2) Cables Through Floor Assemblies Barrier Penetration Type F-Rating F-Rating F-Rating F-Rating System Number Product (Other) Concrete (2.5" min.) 2.5" for CP 653 2" 4.5" for CP 653 4"2 3/4 1 or 7 2 or 7 C-AJ-3281 CP 653 (FS One or CP 606) Concrete (2.5" min.) 3.0" for CP 653 2" 5.0" for CP 653 4"2 1/2 7 7 C-AJ-3283 CP 653 (FS One or CP 618 Putty) Concrete (2.5" min.) 3.0" for CP 653 2" 5.0" for CP 653 4"3 1, 1.5 or 3 1 or 7 2 or 7 C-AJ-3285 CP 653 (FS One or CP 606) Products Recommended CP 606 Flexible Firestop Sealant (acrylic-base) CP 618 Firestop Putty Stick CP 653 Speed Sleeve FS One Intumescent Firestop Sealant (water-base) - Mineral Wool Always refer to the Tested System for comprehensive system details and installation requirements. If an application is encountered and is not addressed in one of the details above, please contact Hilti (800-879-8000). This submittal packagye includes frequentl applied details for the CP 653 Speed Sleeves. (2007 Oct 17) System No. C-AJ-3281 October 12, 2007 F Rating - 2 Hr T Rating - 3/4 Hr L Rating at Ambient - 1 and 7 CFM/sq ft (See Item 2) L Rating at 400F - 2 and 7 CFM/sq ft (See Item 2) 1.Floor or Wall Assembly — Min 2-1/2 in. (64 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Floor may also be constructed of any min 6 in. thick UL Classified hollow-core Precast Concrete Units*. Opening in floor or wall to be max 2-1/2 in. (64 mm) diam for 2" device and max 4-1/2 in. (114 mm) diam for 4" device. See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2.Cables — Within the loading area for each firestop device, the cables may represent a 0 to 100 percent visual fill. Cables to be tightly bundled within the device and rigidly supported on both sides of floor or wall assembly. Any combination of the following types of cables may be used: A. Max 100 pair No. 24 AWG (or smaller) copper conductor telecommunication cable with polyvinyl chloride (PVC) jacketing and insulation. B. Max 7/C No. 12 AWG copper conductor control cable with PVC or XLPE jacket and insulation. C. Max 4/0 AWG Type RHH ground cable. D. Max 4 pr No. 22 AWG Cat 6 computer cables. E. Max RG 6/U coaxial cable with fluorinated ethylene insulation and jacketing. F. Fiber optic cable with polyvinyl chloride (PVC) or polyethylene (PE) jacket and insulation having a max diam of 1/2 in. (13 mm). G. Max 20/C No. 22 AWG shielded printer cable with PVC jacket. H.Through-Penetrating Product* - Two copper conductors No. 18 AWG (or smaller) Power or Non Power Limited Fire Alarm Cable with or without a jacket under a metal armor. AFC CABLE SYSTEMS INC I. Max. ¼" (6 mm) diameter S-Video Cable consisting of 2 max 24 AWG 75 ohm coax or twisted pair cable with PE insulation and PVC jacket . The L Rating for the firestop systems with cables is 7 CFM/sq ft at both ambient and 400F. The L Rating for blank openings with no cables is 1 CFM/sq ft at ambient and 2 CFM/sq ft at 400F. 3.Firestop Device* — Firestop device consists of a corrugated steel tube with an inner plastic housing, intumescent material rings and tightly twisted inner fabric smoke seal. Firestop device to be installed in accordance with the accompanying installation instructions. Device slid into floor or wall such that ends project an equal distance from the approximate centerline of the assembly. The annular space between the device and the periphery of the opening shall be min 0 in. (point contact). Device provided with flanges that are spun clockwise onto device threads, butting tightly to both sides of floor or wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 653 2" Speed Sleeve and CP 653 4" Speed Sleeve 4.Fill, Void or Cavity Material* - Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus between firestop device and periphery of opening, flush with top surface of floor or both surfaces of wall, and an additional 1/4 in. (6 mm) bead applied at the device/floor or wall interface on top side of floor or both sides of wall assembly prior to installing flanges. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE or CP 606 Sealant *Bearing the UL Classification Mark Copyright © 2007 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2007 Underwriters Laboratories Inc.®" System No. C-AJ-3283 October 12, 2007 F Rating — 2 Hr T Rating — 1/2 Hr L Rating at Ambient — 7 CFM/sq ft (See Item 4) L Rating at 400F — 7 CFM/sq ft (See Item 4) 1.Floor or Wall Assembly — Min 2-1/2 in. (64 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Opening in floor or wall to be max 3 in. (76 mm) diam for 2" device and max 5 in. (127 mm) diam for 4" device. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2.Cables — A cable bundle having a min 50 percent visual fill to max 100 percent visual fill within the loading area for the firestop device shall be installed. Cables to be tightly bundled within the device and rigidly supported on both sides of floor or wall assembly. Any combination of the following types of cables may be used: A. Max 100 pair No. 24 AWG (or smaller) copper conductor telecommunication cable with polyvinyl chloride (PVC) jacketing and insulation. B. Max 7/C No. 12 AWG copper conductor control cable with PVC or XLPE jacket and insulation. C. Max 4/0 AWG Type RHH ground cable. D. Max 4 pr No. 22 AWG Cat 6 computer cables. E. Max RG 6/U coaxial cable with fluorinated ethylene insulation and jacketing. F. Fiber optic cable with polyvinyl chloride (PVC) or polyethylene (PE) jacket and insulation having a max diam of 1/2 in. (13 mm). G. Max 20/C No. 22 AWG shielded printer cable with PVC jacket. H.Through-Penetrating Product* - Two copper conductors No. 18 AWG (or smaller) Power or Non Power Limited Fire Alarm Cable with or without a jacket under a metal armor. AFC CABLE SYSTEMS INC I. Max. ¼" (6 mm) diameter S-Video Cable consisting of 2 max 24 AWG 75 ohm coax or twisted pair cable with PE insulation and PVC jacket. 3.Firestop Device* — Firestop device consists of a corrugated steel tube with an inner plastic housing, intumescent material rings and tightly twisted inner fabric smoke seal. Firestop device to be installed in accordance with the accompanying installation instructions. Device slid into floor or wall such that ends project an equal distance from the approximate centerline of the assembly. The annular space between the device and the periphery of the opening shall be min 0 in. (point contact). Device provided with flange(s) that are spun clockwise onto device threads, butting tightly to top side of floor or both sides of wall. In floors, when FS-ONE Sealant is used and installed flush with bottom of floor, device flange shall be threaded tightly to bottom side of floor. In floors, device flange to be secured to floor with min two 1-1/4 in. (32 mm) long masonry screws or anchors. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 653 2" Speed Sleeve and CP 653 4" Speed Sleeve 4.Fill, Void or Cavity Material* — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus between firestop device and periphery of opening, flush with top surface of floor or both sides of wall. As an option, when FS-ONE Sealant is used, the fill material can be installed flush with bottom of floor. L Rating applies only when FS-ONE sealant is used and an additional 1/4 in. (6 mm) bead of fill material applied at the device/floor or wall interface on top or bottom side of floor or both sides of wall assembly prior to installing flanges. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 618 Firestop Putty or FS-ONE Sealant *Bearing the UL Classification Mark Copyright © 2007 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2007 Underwriters Laboratories Inc.®" System No. C-AJ-3285 October 12, 2007 F Rating - 3 Hr T Ratings - 1, 1-1/2 and 3 Hr (See Item 2) L Rating at Ambient - 1 and 7 CFM/sq ft (See Items 2 and 4) L Rating at 400F - 2 and 7 CFM/sq ft (See Items 2 and 4) 1.Floor or Wall Assembly — Reinforced lightweight or normal weight (100-150 pcf or 1600- 2400 kg/m3) concrete. Min 4-1/2 in. (114 mm) thick floors and min 5 in. (127mm) thick walls. Wall may also be constructed of any UL Classified Concrete Blocks*. Floor may also be constructed of any min 6 in. thick UL Classified hollow-core Precast Concrete Units*. Opening in floor or wall to be max 3 in. (76 mm) diam for 2" device and max 5 in. (127 mm) diam for 4" device. See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2.Cables — Within the loading area for each firestop device, the cables may represent a 0 to 100 percent visual fill. Cables to be tightly bundled within the device and rigidly supported on both sides of floor or wall assembly. Any combination of the following types of cables may be used: A. Max 100 pair No. 24 AWG (or smaller) copper conductor telecommunication cable with polyvinyl chloride (PVC) jacketing and insulation. B. Max 7/C No. 12 AWG copper conductor control cable with PVC or XLPE jacket and insulation. C. Max 4/0 AWG Type RHH ground cable. D. Max 4 pr No. 22 AWG Cat 6 computer cables. E. Max RG 6/U coaxial cable with fluorinated ethylene insulation and jacketing. F. Fiber optic cable with polyvinyl chloride (PVC) or polyethylene (PE) jacket and insulation having a max diam of 1/2 in. (13 mm). G. Max 20/C No. 22 AWG shielded printer cable with PVC jacket. H.Through-Penetrating Product* - Two copper conductors No. 18 AWG (or smaller) Power or Non Power Limited Fire Alarm Cable with or without a jacket under a metal armor. AFC CABLE SYSTEMS INC I. Max. ¼" (6 mm) diameter S-Video Cable consisting of 2 max 24 AWG 75 ohm coax or twisted pair cable with PE insulation and PVC jacket. The hourly T Rating for blank openings (no cables) is 3 hr. The hourly T Rating for openings with cables is 1-1/2 hr except that when cable types 2A, 2B, 2C, 2E or 2H are used, the T Rating is 1 hr. The L Rating for the firestop systems with cables is 7 CFM/sq ft at both ambient and 400F. The L Rating for blank openings with no cables is 1 CFM/sq ft at ambient and 2 CFM/sq ft at 400F. 3.Firestop Device* — Firestop device consists of a corrugated steel tube with an inner plastic housing, intumescent material rings and tightly twisted inner fabric smoke seal. Firestop device to be installed in accordance with the accompanying installation instructions. Device slid into floor or wall such that ends project an equal distance from the approximate centerline of the assembly. As an option, in floors, steel sleeve of device may be installed flush with bottom of floor. The annular space between the device and the periphery of the opening shall be min 0 in. (point contact). Device provided with flange(s) that are spun clockwise onto device threads, butting tightly to top side of floor or both sides of floor or wall. In floors, when one device flange is used, device flange to be secured to floor with min two 1-1/4 in. (32 mm) long masonry screws or anchors. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 653 2" Speed Sleeve and CP 653 4" Speed Sleeve 4.Firestop System — The firestop system shall consist of the following: A.Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into annular space between firestop device and opening as a permanent form. Packing material to be installed flush with bottom of floor and recessed from top surface of floor or from both surfaces of wall to accommodate the required thickness of fill material. B.Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. For L Rating, an additional 1/4 in. (6 mm) bead of fill material applied at the device/floor or wall interface on top side of floor or both sides of wall assembly prior to installing flange(s). HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 606 Sealant or FS-ONE Sealant *Bearing the UL Classification Mark Copyright © 2007 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2007 Underwriters Laboratories Inc.®" System No. W-L-3335 October 12, 2007 F Ratings — 1 and 2 Hr (See Item 1) T Ratings — 0, 1, 1-3/4 and 2 Hr (See Item 2) L Ratings at Ambient — Less Than 1 CFM/sq ft, 5 CFM/sq ft and 9 CFM/sq ft (See Items 2 and 4) L Rating at 400F — Less Than 1 CFM/sq ft, 1 CFM/sq ft and 10 CFM/sq ft (See Items 2 and 4) 1.Wall Assembly — The 1 or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described within the individual U300, U400 or V400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall incorporate the following construction features: A.Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B.Gypsum Board* — Nom 5/8 in. (16 mm) thick gypsum board as specified in the individual Wall and Partition Design. Opening in gypsum board to be max 3 in. (76 mm) diam for 2" device and max 5 in. (127 mm) diam for 4" device. The hourly F Rating of the firestop system is dependent upon the hourly rating of the wall in which it is installed. 2.Cables — Within the loading area for each firestop device, the cables may represent a 0 to 100 percent visual fill. Cables to be tightly bundled within the device and rigidly supported on both sides of wall assembly. Any combination of the following types of cables may be used: A. Max 100 pair No. 24 AWG (or smaller) copper conductor telecommunication cable with polyvinyl chloride (PVC) jacketing and insulation. B. Max 7/C No. 12 AWG copper conductor control cable with PVC or XLPE jacket and insulation. C. Max 4/0 AWG Type RHH ground cable. D. Max 4 pr No. 22 AWG Cat 6 computer cables. E. Max RG 6/U coaxial cable with fluorinated ethylene insulation and jacketing. F. Fiber optic cable with polyvinyl chloride (PVC) or polyethylene (PE) jacket and insulation having a max diam of 1/2 in. (13 mm). G. Max 20/C No. 22 AWG shielded printer cable with PVC jacket. H.Through-Penetrating Product* - Two copper conductors No. 18 AWG (or smaller) Power or Non Power Limited Fire Alarm Cable with or without a jacket under a metal armor. AFC CABLE SYSTEMS INC I. Max. ¼" (6 mm) diameter S-Video Cable consisting of 2 max 24 AWG 75 ohm coax or twisted pair cable with PE insulation and PVC jacket . See Table below for T Ratings for openings with cables. For blank openings (no cables) with 2" device, the T Rating for the firestop system equals the F Rating . For blank openings with 4" device, the T Rating is 1-3/4 hr for 2 hr fire walls and 0 hr for 1 hr fire rated walls. Openings With Cables Device Size F Rating, hr Fill Material T Rating, hr 2 and 4 1 All 0 2 and 4 2 CP 606 or FS- ONE 0 2 CP 618 Putty 1-3/4 (for all cable types except 2C, 2G and 2I) 2 CP 618 Putty 1 (for cable types 2C, 2G and 2I) L Ratings apply only when CP 606 or FS-ONE Sealant is used. For blank (no cables) openings, the L Rating at Ambient and 400F is Less Than 1 CFM/sq ft. For openings with cables, the L Rating is 9 CFM/sq ft at Ambient and 10 CFM/sq ft at 400F. For openings with Cat 6 cables only (Item 2D), the L Rating is 5 CFM/sq ft at Ambient and 1 CFM/sq ft at 400F. 3.Firestop Device* — Firestop device consists of a corrugated steel tube with an inner plastic housing, intumescent material rings and tightly twisted inner fabric smoke seal. Firestop device to be installed in accordance with the accompanying installation instructions. Device slid into wall such that ends project an equal distance from the approximate centerline of the wall assembly. Device provided with flanges that are spun clockwise onto device threads, butting tightly to both sides of wall. The annular space between the device and the periphery of the opening shall be min 0 in. (point contact). Device flanges are to be secured to wall with min two 1-1/2 in. (38 mm) long drywall screws. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 653 2" Speed Sleeve and CP 653 4" Speed Sleeve 4.Fill, Void or Cavity Material* — Min 5/8 in. (16 mm) thickness of fill material applied within the annulus between firestop device and wall, flush with both surfaces of wall. For L-rating, apply an additional ¼ in. (6 mm) bead of FS-ONE or CP 606 at the device/wall interface on both sides of wall prior to installing flanges. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant, CP 606 Sealant or CP 618 Putty *Bearing the UL Classification Mark Copyright © 2007 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2007 Underwriters Laboratories Inc.®" Product Information Chapter TabsChapter TabsChapter TabsChapter TabsChapter Tabs Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com •en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education CP 606 Flexible Firestop Sealant CP 606 Technical Data Chemical basis Acrylic based firestop sealant Color Available in red or white Application temperature 40°F to 104°F (5°C to 40°C) Skin-forming time Approx. 15 min Curing time Approx. 3 mm / 3 days Volume shrinkage Less than 20% Movement capability Approx. 10% Temperature resistance –22°F to 176°F (–30°C to 80°C) Surface burning characteristics Flame Spread: 0 (ASTM E 84-96) Smoke Development: 5 Sound transmission classification 56 (Relates to specific construction) (ASTM E 90-99) Approvals California State Fire Marshal Listing No. 1452-1200:112 Listing No. 1451-1200:121 Listing No. 4485-1200:132 City of New York MEA 100-99-M, Vol. IV Tested in accordance with • UL 2079 • ASTM E 814 • ASTM E 1966 • ASTM E 84 • UL 1479 At 73°F (23°C) and 50% relative humidity FM APPROVED FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS AND JOINT SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Product description • An acrylic based firestop sealant that provides movement capability in fire rated joints and seals through penetrations applications Product features • Silicone free • Halogen, asbestos and solvent free • UV-resistant • Paintable • Meets 500 cycle requirements (ASTM E 1966 & UL 2079) • Smoke, fume and water resistant • Easy clean up with water • Single component systems available • Meets LEED™ requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application • Sealing construction/expansion joints • Top-of-wall joints • Metal pipes • Cable bundles • HVAC penetrations For use with • Various base materials such as masonry, concrete, metal, etc. • Wall and floor assemblies rated up to 3 hours Examples • Where a gypsum wall assembly meets the underside of a metal or concrete deck • Sealing expansion joints to impede the passage of fire, smoke and toxic fumes • Sealing around HVAC penetrations through fire-rated assemblies Notice • Before handling, read Material Safety DataSheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the opening. Surfaces to which CP 606 will be applied should be cleaned of loose debris, dirt, oil, wax and grease. The surface should be moisture and frost free. Application of firestop 2. Insert fill of mineral wool or backer (as required). 3. Apply firestop over backer. 4. Smooth firestop sealant with a trowel before the skin forms. Once cured, CP 606 can only be removed mechanically. 5. For maintenance reasons, a penetration seal can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • On areas immersed in water Storage • Store only in the original packaging in a location protected from moisture at a temperature of 40°F to 77°F (5°C to 25°C) • Observe expiration date on package Installation instructions for CP 606 1. Clean opening 2. Insert backing material compressed per UL System 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification plate (if required) 1. Clean opening 2. Insert backing material 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification plate (if required) FirestopSystem FirestopSystemJOINTDUCT Product Information Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com •en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs CP 618 Firestop Putty Stick Product description • An intumescent, non-hardening, firestop putty for cable and pipe penetrations Product features • Contains no volatile solvents or asbestos • Easy to re-penetrate Areas of application • Single or bundled cables • Non-combustible pipe • Blank openings • Reusable • Easy to add or subtract cables • Fast installation For use with • Concrete, masonry and gypsum wall assemblies • Wall and floor assemblies rated up to 3 hours Examples • Where telecommunication and data lines penetrate gypsum wall assemblies • Where steel conduit and EMT penetrate concrete and block wall assemblies • Where blank openings exist in concrete and block wall assemblies Installation instructions for CP 618 CP 618 Technical Data Dimensions 18 in 3 Consistency Moldable putty Color Red Application temperature 40°F to 95°F (5°C to 35°C) Cure Non-curing Density Approx. 1.48 g/cm 3 Intumescent activation Approx. 220°F to 250°F (104°C to 121°C) Surface burning characteristics Flame Spread: 5 (ASTM E84-96) Smoke development: 5 Sound transmission classification 49 (Relates to specific construction) (ASTM E 90-97) Approvals California State Fire Marshal Listing No. 4485-1200:111 City of New York MEA-98-99-M Tested in accordance with • UL 1479 • ASTM E 814 • ASTM E 84 At 73°F (23°C) and 50% relative humidity Notice • Before handling, read Material Safety DataSheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the opening: Surfaces to which CP 618 will be applied should be cleaned of loose debris, dirt, oil, moisture, frost and wax. Application of firestop putty 2. Install the prescribed backing material, if required. 3. Install CP 618 Firestop Putty to the required depth, making sure that the putty contacts all surfaces to provide the greatest adhesion. 4. Smooth CP 618 putty. 5. For maintenance reasons, a penetration seal can be permanently marked with an identification plate and fastened in a visible position next to the seal. 6. Re-installation (not shown): Remove and re-install CP 618 Firestop Putty as needed. Not for use • In areas exposed to water Storage • Store only in the original packaging at temperatures 40°F to 104°F (5°C to 40°C) FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM APPROVED 1. Clean opening 2. Slice CP 618 to be packed into opening from stick (optional sleeve) 3. Pack in CP 618 4. Smooth CP 618 5. Fasten installation plate (if required) Hilti CP 653 Speed Sleeve Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 www.us.hilti.com/espanol • Hilti (Canada) Corp.1-800-363-4458 www.hilti.ca Hilti. Outperform. Outlast. When easy or quick aren’t good enough. Healthcare managers, telecom and datacom professionals, and electrical trades understand the importance of life safety and asset preservation. When selecting the correct cable management device, they know the right product addresses a multitude of performance criteria. These aspects include fast product installation, ease of cable penetration and re-penetration, superior ability to limit smoke migration whether empty or 100% visual-fill, a wide portfolio of firestop details, and a robust, lightweight solution that endures long-term, high-traffic usage. The Hilti CP 653 Speed Sleeve is a ready-to-use, one-step cable management firestop device that addresses all of these needs. Innovations Fast installation • Round openings can be created via hole saws or core bits • “Spin on” flanges promote fast product installation Fast cable installation • Cables do not need to be inserted in a uniform height to comply with the firestop detail Easy penetration and re-penetration • Opening and closing the device is easy and intuitive: from one side of the CP 653, depress the red tabs and twist the inner housing Extremely low L-ratings • Constrictive smoke seal limits smoke migration: - Less than 1 cfm/ft2 for empty device - 5 cfm/ft2 possible for cable bundles Withstands the rigors of usage and time • Robust smoke seal fabric tested to 250 open-close cycles Ordering Information Item No. Description Qty 236323 CP 653 2" Speed Sleeve 1 236324 CP 653 4" Speed Sleeve 1 Always refer to the MSDS before use and the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information. 1. Use either a 2.5" or 4.5" hole saw to create the appropriate hole. 2. Insert the sleeve. 3. Seal the gap with firestop sealant to impede smoke and gas migration. Repeat on other side of the wall 4. Spin the flange clockwise onto the device. Repeat on other side of the wall. 5. To open the device: (a) On one side of the wall, press the clip closures inward. (b) Twist the device counterclockwise. 6.To close the device: (a) On the same side of the wall, press the clip closures inward. (b) Twist the device clockwise until finger-tight, allowing it to engage with a click. For repenetration of cables, repeat steps 5 & 6. For installation options not presented here, consult your local Hilti representative for other rated firestop systems. Installation Instructions 123456 CP 653 Technical Data Device OD (device only) OD (flange) ID Total length Weight (device and flanges) 2" 2.3 in 4.7 in 1.7 in 12.4 in 1.5 lbs 4" 4.3 in 6.7 in 3.7 in 12.4 in 2.6 lbs Density Approx. 1.35 g/cm 3 Temperature resistance 22°F to 212°F (-30°C to 100°C) Intumescent activation Approx. 320°F (160°C) Expansion ratio (unrestricted) 1:40 Metal Steel with zinc coating Plastic ABS Fabric Glass-fiber Approvals California State Fire Marshal In Progress City of New York In Progress Internationally tested and approved FM APPROVED Product Information Chapter TabsChapter TabsChapter TabsChapter TabsChapter Tabs Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com •en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. sodfm,ev iJdjfiwhriuh. N öoWE Z8Z23aw öp3i4e ß 0288 u 2 7uz e 4i5kirdwiloi4jtf-öx-.vbvbvh, i reiv u9+ß12oeo o tlke0´9^)&(/R 84tc ) v 6453 FS-ONE High Performance Intumescent Firestop Sealant FS-ONE Technical Data Chemical basis Water-based intumescent acrylic dispersion Color Red Application temperature 40°F to 104°F (5°C to 40°C) Skin forming time Approx. 20-30 min. Curing time Approx. 2 mm / 3 days Movement capability Approx. 5% Expansion rate Up to 3-5 times (unrestricted): original volume Temperature resistance (cured) –40°F to 212°F (–40°C to 100°C) Surface burning characteristics Flame Spread: 0 (ASTM E 84-96) Smoke Development: 5 Sound transmission classification 56 (Relates to specific construction) (ASTM E 90-99) Approvals California State Fire Marshal Listing No. 4485-1200:108 City of New York MEA 326-96-M Vol. IV Tested in accordance with • UL 1479 • ASTM E 814 • ASTM E 84 At 73°F (23°C) and 50% relative humidity FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM APPROVED Product description • Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Product features • Smoke, gas and water resistant after material has cured • Contains no halogen, solvents or asbestos • High fire rating properties • Water based, easy to clean • Protects most typical firestop penetration applications • Can be painted • Single component systems available • Meets LEED™ requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application • Steel, copper and EMT pipes • Insulated steel and copper pipes • Cable bundles • Closed or vented plastic pipes • HVAC penetrations For use with • Concrete, masonry, drywall and wood floor assemblies • Wall and floor assemblies rated up to 4 hours Examples • Sealing around plastic pipe penetrations in fire rated construction • Sealing around combustible and non-combustible penetrations in fire rated construction 1. Clean opening. 2. Pack mineral wool. (If required) 3. Apply FS-ONE. 4. Smooth FS-ONE. 5. Leave completed seal undisturbed for 48 hours. 6. Fasten identification plate (if required). 1. Clean opening. 2. Pack mineral wool. (If required) 3. Apply FS-ONE. 4. Smooth FS-ONE. 5. Leave completed seal undisturbed for 48 hours. 6. Fasten identification plate (if required). Firestop System Notice • Before handling, read Material Safety DataSheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the opening. Surfaces to which FS-ONE will be applied should be cleaned of loose debris, dirt, oil, moisture, frost and wax. Structures supporting penetrating items must be installed in compliance with local building and electrical standards. Application of firestop sealant 2. Install the prescribed backfilling material type and depth to obtain the desired rating (if required). Leave sufficient depth for applying FS-ONE. 3. Application of firestop sealant: Apply FS-ONE to the required depth in order to obtain the desired fire rating. Make sure FS-ONE contacts all surfaces to provide maximum adhesion. For application of FS-ONE use a standard caulking gun, foil pack gun, bulk loader and bulk gun. With FS-ONE buckets, Graco type sealant pumps may be used. (Contact pump manufacturer for proper selection). 4. Smoothing of firestop sealant: To complete the seal, tool immediately to give a smooth appearance. Excess sealant, prior to curing, can be cleaned away from adjacent surfaces and tools with water. 5. Leave completed seal undisturbed for 48 hours. 6. For maintenance reasons, a penetration seal could be permanently marked with an identification plate. In such a case, mark the identification plate and fasten it in a visible position next to the seal. Not for use • High movement expansion joints • Underwater • On materials where oil, plasticizers or solvents may bleed i.e. impregnated wood, oil based seals, green or partially vulcanized rubber • In any penetration other than those specifically described in this manual or the test reports Storage • Store only in the original packaging in a location protected from moisture at temperatures between 40°F (5°C) and 86°F (30°C) • Observe expiration date on the packaging Installation instructions for FS-ONE FirestopSystemFirestopSystemCABLEPIPE Material Safety Data Sheet Chapter TabsChapter TabsChapter TabsChapter TabsChapter TabsEstimating Tables/Tech DataHilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education 188 MSDS No.: 267 Revision No.: 008 Revision Date: 06/07/0 Page: 1 of 2 Product name: CP 606 Flexible Firestop Sealant Description: Fire resistant sealant Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: TLV: PEL: STEL: Calcium carbonate 01317-65-3 NE 5 (R) mg/m3 NE Polybutene 09003-29-6 NE NE NE Ethylene glycol 00107-21-1 C: 100 mg/m3 (A) NE NA Pigments: NE NE NE • Titanium dioxide 13463-67-71 10 mg/m3 15 (T) mg/m3 NE • Red iron oxide 1309-37-12 5 (R) mg/m3 10 (fume) mg/m3 NE • Black Iron oxide 1317-61-93 NE NE NE Isononyl phthalate 28553-12-0 NE NE NE 1 CP 606 white; 2 CP 606 red, 1,3 CP 606 grey Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. (R)= Respirable dust (T)= Total dust (A)= Aerosol PHYSICAL DATA Appearance: White or red paste. Odor: Negligible. Boiling Point: Not applicable. Vapor Pressure: Not applicable. Melting Point: Not determined. VOC Content: 71.0 g/L Evaporation Rate: Not applicable. Solubility in Water: Miscible. pH: Not determined. Specific Gravity: 1.55 FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable. Flammable Limits:Not applicable. Fire / Explosion Hazards:None known. Extinguishing Media: As appropriate for surrounding fire; material itself does not burn. Special Fire Fighting Procedures:As appropriate for surrounding fire. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong oxidizing agents. Hazardous Decomposition Products:Not applicable. Conditions to Avoid: Avoid temperature extremes that could shorten the shelf life of this product. See handling and storage requirements. HEALTH HAZARD DATA Known Hazards: Acute: Product is slightly alkaline; minor irritation is possible. Chronic:None known. Signs and Symptoms of Exposure: Eyes — Can cause slight irritation but injury is unlikely. Skin — Can cause irritation with some individuals. Inhalation — No effects expected. Ingestion — Not considered to be a route of exposure. Effects of ingestion have not been determined. Routes of Exposure: Inhalation, Dermal. Medical Conditions Eye, skin, and respiratory conditions. Aggravated by Exposure: Carcinogenicity:No ingredients are classified as a carcinogen by IARC, NTP or OSHA. Material Safety Data Sheet Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education 189 Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs Chapter TabsEstimating Tables/Tech DataMSDS No.: 267 Revision No.: 008 Revision Date: 06/07/0 Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Flush with plenty of water. Contact a Physician if symptoms occur. Skin: Wash with soap and water. Inhalation:Move victim to fresh air. Call a Physician if symptoms occur. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a Physician. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Safety glasses with side shields.. Skin Protection: Impermeable gloves are recommended. Respiratory Protection:Not normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions:Store in a cool dry area. Keep from freezing. Shelf life is one year from date of manufacture if stored between 40° and 77° F (5 - 25° C). For industrial use only. Keep out of reach of children. Keep container sealed when not in use to prevent curing of the product. Avoid contact with the eyes and skin. Practice good hygiene; i.e. wash after using and before eating or smoking. Spill Procedures: Allow to cure and place in a container for proper disposal in accordance with all applicable local, state, or federal requirements. Not regulated as a hazardous waste according to federal EPA definitions. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes:Health 1, Flammability 0, Reactivity 0, PPE B (Gloves, Glasses) DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product contains approximately 3% ethylene glycol which is subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service:1 800 879 8000 Health / Safety:1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem-Trec):1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. Material Safety Data Sheet Chapter TabsChapter TabsChapter TabsChapter TabsChapter TabsHilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education MSDS No.: 263 Revision No.: 005 Revision Date: 3/1/05 Page: 1 of 2 Product name: CP 617 Firestop Putty Pad; CP 618 Firestop Putty Stick; CP 619T Firestop Putty Roll Description: Firestopping putty Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: TLV: PEL: STEL: Triazine triamine phosphate 41583-09-9 NE NE NE Calcium borate 12007-56-6 NE NE NE Polyphosphoric acid 68333-79-9 NE NE NE Isodecyldiphenyl ester 29761-21-5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. PHYSICAL DATA Appearance: Rust colored putty Odor: Negligible Vapor Density: (air = 1) Not applicable Vapor Pressure: Not applicable Boiling Point: Not applicable VOC Content: 5.2 g/l — CP 617, CP 619T 14.5 g/l — CP 618 Evaporation Rate: Not applicable Solubility in Water: Slightly soluble Specific Gravity: 1.48 pH: Not determined FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable Flammable Limits: Not applicable Extinguishing Media: Water, CO2, Dry Chemical, Foam Special Fire Fighting Procedures: A NIOSH-approved self-contained breathing apparatus (SCBA) should be worn when fighting fires involving chemical products. Unusual Fire and Explosion Hazards: Fire conditions will activate product causing it to intumesce. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, bases and oxidizing agents. Decomposition Products:Thermal decomposition can yield oxides of carbon and nitrogen. Conditions to Avoid: Avoid temperature extremes that could shorten the shelf-life or affect product performance; i.e. below freezing and above 100° F. (See handling and storage requirements). HEALTH HAZARD DATA Known Hazards: Irritation of the eyes and skin is possible. Signs and Symptoms of Exposure: Eyes — Can cause irritation and watering but injury is unlikely. Skin — Can cause irritation. Inhalation — No effects expected. Not considered to be a route of exposure. Ingestion — Can cause nausea and vomiting. Considered to have a low acute oral toxicity. Routes of Exposure: Contact Carcinogenicity: No ingredients are classified as a carcinogen by IARC, NTP or OSHA. Medical Conditions Aggravated None known. by Exposure: Material Safety Data Sheet Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs MSDS No.: 263 Revision No.: 005 Revision Date: 3/1/05 Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Wash with soap and water. Seek medical attention if any effects persist. Inhalation: No effects expected. Ingestion: If conscious, give plenty of water to drink. Never give anything by mouth to an unconscious person. Do not induce vomiting unless directed by a physician. Contact a physician immediately. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Cloth gloves are suitable; impermeable (neoprene or rubber) gloves recommended. Respiratory Protection:Not required. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area. Keep from freezing. For industrial use only. Keep out of reach of children. Avoid prolonged or repeated contact with the skin. Do not rub the eyes after contact with the hands. Practice good hygiene; i.e. wash after using and before eating or smoking. Spill Procedures: No special requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard. 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product does not contain any ingredients that are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s):Not regulated by EPA as a hazardous waste Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service:1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. Material Safety Data Sheet Chapter TabsChapter TabsChapter TabsChapter TabsChapter TabsHilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education Product name: CP 653 - Speed Sleeve Description:Reusable Firestop Insert containing a black intumescent material Supplier:Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Not applicable. This product is considered to be an “article” as defined in the federal OSHA Hazard Communication Standard 29 CFR 1910.1200 / 1926.59. PHYSICAL DATA Appearance:Galvanized metal sleeve Odor: None. with red plastic ends Vapor Density:(air = 1) Not applicable. Vapor Pressure: Not applicable. Boiling Point:Not applicable. VOC Content:7.6 g/l Evaporation Rate: Not applicable. Solubility in Water:Not determined. Specific Gravity:Not determined. pH:Not applicable. FIRE AND EXPLOSION HAZARD DATA Flash Point:Not applicable. Flammable Limits:Not applicable. Extinguishing Media:Use extinguishing media appropriate for surrounding fire. Special Fire Fighting Procedures:None known. Unusual Fire and Explosion Hazards:None known. Product serves as a firestop; intumescent material metal sleeve expands when exposed to temperatures > 160°C / 320°F. REACTIVITY DATA Stability:Stable. Hazardous Polymerization: Will not occur. Incompatibility:None known. Decomposition Products: None known. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Routes of Exposure: None known. Signs and Symptoms of Exposure: None expected from routine use/installation according to manufacturer's specifications and technical guides. Carcinogenicity:No ingredients are classified as a carcinogen by IARC, NTP or OSHA. Medical Conditions Aggravated None known. by Exposure: EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Not applicable. Practice good hygiene; i.e. wash hands during breaks, before eating or smoking, and after work. Inhalation:Not applicable. Ingestion: Not a potential route of exposure. Other: Referral to a physician is recommended if there is any question about the seriousness of any injury/exposure. MSDS No.: 321 Revision No.: 000 Revision Date: 10/05/07 Page: 1 of 2 Material Safety Data Sheet Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: None required; however, gloves recommended. Respiratory Protection: No respiratory protection is needed for normal application of this product. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool dry area. Follow installation instructions. Spill Procedures: No special requirements. REGULATORY INFORMATION Hazard Communication: This product is considered to be an “article” as defined in the federal OSHA Hazard Communication Standard. DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product is classified as an "article" and is not subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service:1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. MSDS No.: 321 Revision No.: 000 Revision Date: 10/05/07 Page: 2 of 2 Material Safety Data Sheet Chapter TabsChapter TabsChapter TabsChapter TabsChapter TabsHilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 1 of 2 Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m3 (T) 10 mg/m3 (T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m 3 NE Expandable graphite 012777-87-6 5 mg/m3 (T) 2 mg/m3 (T) NE Ethylene glycol 000107-21-1 NE C:100 mg/m3 (A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m3 5 mg/m3 NE Glass filament 065997-17-3 NE 5 mg/m3 (T) NE Silicon dioxide 014808-60-7 0.05 mg/m 3 (T) 0.1 mg/m3 (T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (T) indicates “as total dust”. (R)indicates “as respirable fraction”. (A)indicates “as an aerosol”. mppcf = million particles per cubic foot. PHYSICAL DATA Appearance:Red paste. Odor: Odorless. Vapor Density: (air = 1) Not determined. Vapor Pressure: 23mbar @ 20C / 68F Boiling Point: Not applicable. VOC Content: 75.0 g/L. Evaporation Rate:Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures:None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides, and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. Material Safety Data Sheet Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs Chapter Tabs MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 2 of 2 Carcinogenicity: IARC classifies crystalline silica (quartz sand) as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local, state, or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product contains < 3% ethylene glycol (CAS 107-21-1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service:1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. Material Safety Data Sheet Chapter TabsChapter TabsChapter TabsChapter TabsChapter TabsHilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop Saving Lives through innovation and education MSDS No.: 270 Revision No.: 004 Revision Date: 10/11/05 Page: 1 of 2 Product name: Mineral Wool Description: Synthetic vitreous fiber Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Slag wool fiber 65997-17-3 NE 1 fiber / cc NE Phenolic resin 09003-35-4 NE NE NE Polyvinyl alcohol 09002-89-5 NE NE E Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. PHYSICAL DATA Appearance: 2' x 4' x 4" sheets. Odor: Negligible. Boiling Point: Not applicable. Vapor Pressure: Not applicable. Melting Point: Approx. 2400° F VOC Content: < 1% w/w Evaporation Rate: Not applicable. Solubility in Water:Insoluble. pH: Not applicable. Specific Gravity:Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable. Flammable Limits: Not applicable. Extinguishing Media: As appropriate for surrounding fire; material does not burn. Special Fire Fighting Procedures:Soak cartons to help prevent the spread of fire. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids. Hazardous Decomposition Products: Thermal decomposition products can be formed at temperatures exceeding 2000° F. Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: Acute:Eye, skin and respiratory irritation. Chronic: Respiratory impairment. Routes of Exposure: Inhalation, Dermal. Signs and Symptoms of Exposure: Eyes: Mechanical irritation. Skin:Itching, irritation. Inhalation: Nose, throat and upper respiratory tract irritation. Carcinogenicity:Slag wool has been classified by the IARC as Group 3 —Unclassifiable as to Carcinogenicity in Humans. Medical Conditions Eye, skin, and respiratory conditions. Aggravated by Exposure: B H B = R E S P O N S I V E N E S S + C O O R D I N A T I O N + C R E A T I VI T Y BHB STRUCTURAL Ϯϳϲϲ^ŽƵƚŚDĂŝŶ^ƚƌĞĞƚ ^Ăůƚ>ĂŬĞŝƚLJ͕hdϴϰϭϭϱ Ɖ͘ϴϬϭϯϱϱϱϲϱϲ ďŚďĞŶŐŝŶĞĞƌƐ͘ĐŽŵ December 17, 2018 YasameenAllami The Richardson Design Partnership 510 South 600 East Salt Lake City, UT 84102 Re: 180876 Marriott, La Quinta CA Dear Yasameen, The purpose of this letter is to address a request from Edgar Gonzalez, the Fire Marshall for La Quinta, CA pertaining to the fire sprinkler lines. The fire sprinkler system is considered part of the mechanical load. The weight of sprinkler piping is included in the mechanical loading which is 5 psf and the collateral load of the structure which is 4 psf for the roof. For the floor, 4 psf has been allotted for mechanical ducts, ceilings and piping and an additional load of 0.5 psf for collateral. The structure as designed is adequate to support this piping. Sincerely, Sam Albano, Project Engineer Scott Pettit, CEO BHB Consulting Engineers BHB Consulting Engineers ,PE 18 December 17, 2018