Loading...
BCOM2020-0004ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AJ ORTEGA 2/21/2020 2/24/2020 EMAIL RECEIVED FROM BUSINESS OWNER THAT PLANS ARE BEING REDRAWN UNDER NEW ARCHITECT, THEY WILL HAVE NEW PLANS TO REVIEW WITHIN 10-DAYS. E-MAIL AJ ORTEGA 8/12/2020 8/12/2020 EMAILED CONTRACTOR (JADOLAN@VERIZON.NET) WITH TODAYS FRAMING INSPECTION CORRECTIONS, IF THEY HAVE ANY QUESTIONS THEY ARE ASKED TO PLEASE CALL. E-MAIL JAKE FUSON 3/24/2020 3/24/2020 NOTIFIED SERGIO GARCIA OF 1ST REVIEW CORRECTIONS. Description: LA QUINTA PET HOSPITAL / 2,527SF TENANT IMPROVEMENT Type: BUILDING COMMERCIAL (WEB) Subtype: REMODEL Status: FINALED Applied: 1/23/2020 AMA Parcel No: 643220025 Site Address: 78555 HIGHWAY 111 STE 200 LA QUINTA,CA 92253 Approved: 6/11/2020 JFU Subdivision: PM 29791 Block: Lot: 1 Issued: 6/11/2020 Online Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/5/2020 AOR Valuation: $30,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: LA QUINTA PET HOSPITAL / 2,527SF VETERINARY SERVICES TENANT IMPROVEMENT [VB/B-OCC/17-OL/SPRINKLED] NO TUMF ASSESSMENT PER 2018 HANDBOOK. ACCESSIBLE CURB RAMP TO BE CONSTRUCTED AS PATH OF TRAVEL UPGRADE. 2019 CALIFORNIA BUILDING CODES. REVISION 2 - FIELD CHANGES - REVISED LAYOUT, UPDATED SINK LOCATIONS + LIGHT FIXTURE REPLACEMENTS. PATH OF TRAVEL UPGRADES RE-EVALUATED AND UNDERTAKEN THROUGH PERMIT BCOM2020-0026. SEE THE UPDATED P.O.T. UPGRADE DETERMINATION FORM AND UPGRADES SHOWN ON PLANS OF BCOM2020-0026. THESE UPGRADES WILL ENCOMPASS THE ALTERATIONS OF SUITES 100 & 200, AND THE UPGRADES SHOWN ON BCOM2020-0004 WILL BE NULLIFIED. Printed: Thursday, October 05, 2023 11:04:22 AM 1 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT WENDELL VEITH 80300 ULLS WATER DR INDIO CA 92203 (760)880-6796 WVEITH36@YAHOO.C OM CONTRACTOR J A DOLAN GENERAL CONTRACTOR INC 74794 42ND AVE STE 6 PALM DESERT CA 92260- 7910 (760)880-6796 jadolan@verizon.net OWNER JDD 78555 HIGHWAY 111 LA QUINTA CA 92253 (760)880-6796 CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST JAKE FUSON 6/11/2020 6/11/2020 COMPLETE CONTRACTOR REQUIRED IN ORDER TO ISSUE. contractor E-MAIL JAKE FUSON 4/27/2020 4/27/2020 NOTIFIED DESIGNER SERGIO OF THE 3RD REVIEW COMMENTS, SENT CORRECTION LIST VIA EMAIL AND EXPLAINED TO HIM THAT I AM AVAILABLE TO PROVIDE ANY SUPPORT HE MAY NEED TO GET THESE ITEMS CORRECTED IN ORDER TO GET THE PERMIT ISSUED. E-MAIL JAKE FUSON 5/14/2020 5/14/2020 NOTIFIED APPLICANT AND TENANT OF 4TH REVIEW COMMENTS. E-MAIL JAKE FUSON 6/11/2020 6/11/2020 NOTIFIED SERGIO AND DR. ALLEN THAT PLANS ARE APPROVED AND PERMIT IS READY TO ISSUE PENDING CONTRACTOR. E-MAIL JAKE FUSON 10/8/2020 10/8/2020 NOTIFIED NEW DESIGNER (ANDREW HERNANDEZ) THAT REVISION 2 PLANS ARE APPROVED AND FEE IS READY FOR PAYMENT. PUBLIC COUNTER VISIT AARON HICKSON 3/12/2020 3/12/2020 SERGIO GARCIA SUBMITTED NEW PLANS REQUESTED A LETTER OF REMOVAL FROM ARCHITECT AFTER CHECKING PLANS THE ARCHETECT IS STILL WENDELL VEITH. SET REVIEW STARTING 3/5/2020 WHEN SUBMITTAL MADE RESUBMITTAL AJ ORTEGA 4/17/2020 4/17/2020 ATTACHED PLAN COMPLETE, PENDING APPLICANT RESPONSES FOR RECHECK. CONDITIONS Printed: Thursday, October 05, 2023 11:04:22 AM 2 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL PRIMARY CONTACT SGS DESIGNS 49950 JEFFERSON ST INDIO CA 92201 (760)880-6796 SGSDESIGN5676@GMA IL.COM FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY RE-INSPECTION FEE 101-0000-42400 0 $80.50 $80.50 9/23/20 WEB6323 71239G CREDIT J A DOLAN GENERAL CONTRACTOR INC ECON RE-INSPECTION FEE 101-0000-42400 0 $80.50 $80.50 9/29/20 WEB6379 70324G CREDIT J A DOLAN GENERAL CONTRACTOR INC ECON RE-INSPECTION FEE 101-0000-42400 0 $80.50 $80.50 11/4/20 WEB6680 56177G CREDIT J A DOLAN GENERAL CONTRACTOR INC ECON Total Paid for ADMINISTRATIVE: $241.50 $241.50 HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 9/16/20 R62378 050514 DEBIT GERHARD H J SCHULZE AMA HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 2.5 $402.50 $402.50 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 10/9/20 R62690 WEB6473 CREDIT JOSEPH DOLAN AMA Total Paid for BLDG CITY STAFF - PER HOUR: $644.00 $644.00 BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $2.00 DEVICES, FIRST 20 101-0000-42403 0 $26.83 $26.83 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON DEVICES, FIRST 20 PC 101-0000-42600 0 $26.83 $26.83 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Printed: Thursday, October 05, 2023 11:04:22 AM 3 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $88.44 $88.44 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $22.11 $22.11 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for ELECTRICAL 2019: $164.21 $164.21 101-0000-42600 ($125.00)($125.00)2/7/20 OFFSET OFFSET KHET FIRE COMMERCIAL TI 101-0000-42421 0 $125.00 $125.00 2/7/20 DEPOSIT DEPOSIT KHET FIRE COMMERCIAL TI 101-0000-42421 0 $36.00 $36.00 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON FIRE COMMERCIAL TI PC 101-0000-42420 0 $242.00 $242.00 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for FIRE FEES: $278.00 $278.00 OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $40.25 $40.25 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $40.25 $40.25 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON VENT FAN 101-0000-42402 0 $13.42 $13.42 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON VENT FAN PC 101-0000-42600 0 $5.37 $5.37 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for MECHANICAL 2019: $99.29 $99.29 PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 $125.00 1/23/20 R58633 251379 DEBIT WENDELL VEITH AMA Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 $125.00 FIXTURE/TRAP 101-0000-42401 0 $26.84 $26.84 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON FIXTURE/TRAP PC 101-0000-42600 0 $26.84 $26.84 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Printed: Thursday, October 05, 2023 11:04:22 AM 4 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY WATER HEATER/VENT 101-0000-42401 0 $13.42 $13.42 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON WATER HEATER/VENT PC 101-0000-42600 0 $8.05 $8.05 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.42 $13.42 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.42 $13.42 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for PLUMBING 2019: $101.99 $101.99 RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 $21.00 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 REMODEL, EA ADDITIONAL 500SF 101-0000-42400 0 $120.75 $120.75 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON REMODEL, EA ADDITIONAL 500SF PC 101-0000-42600 0 $96.60 $96.60 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON REMODEL, FIRST 100SF 101-0000-42400 0 $54.74 $54.74 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON REMODEL, FIRST 100SF PC 101-0000-42600 0 $149.73 $149.73 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for REMODEL 2019: $421.82 $421.82 SMI - COMMERCIAL 101-0000-20308 0 $8.40 $8.40 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for STRONG MOTION INSTRUMENTATION SMI: $8.40 $8.40 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 Printed: Thursday, October 05, 2023 11:04:22 AM 5 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FRAMING JFU 7/14/2020 7/14/2020 NOT READY WORK INCOMPLETE. RECALL WHEN FRAMING AND ROUGH MEP WORK IS COMPLETE AND READY FOR INSPECTION. FRAMING AOR 8/12/2020 8/12/2020 DISAPPROVE D FRAMING OF WALLS DOES NOT MATCH APPROVED PLAN AND CEILING DESIGN MISSING FOR REMOVING EXISTING WALLS AND RETAINING HARDLID CEILING. THE SCOPE OF WORK HAS ALSO CHANGED AND REVISIONS HAVE NOT BEEN SUBMITTED FOR REVIEW AND APPROVAL. IN ORDER TO PROCEED WITH CONSTRUCTION PLEASE PROVIDE REVISED PLANS FOR THE PROPOSED CHANGES AND A STRUCTURAL DESIGN FROM A REGISTERED DESIGN PROFESSIONAL FOR THE FRAMING OF WALLS AND CEILINGS THROUGHOUT, INCLUDING EXISTING TO NEW CONSTRUCTION. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY ALTERATIONS/ADDITIO NS - NON-RESIDENTIAL 101-0000-42400 0 $161.00 $161.00 6/11/20 WEB5425 CREDIT J A DOLAN GENERAL CONTRACTOR I ECON Total Paid for ZONING CLEARANCE - PLANNING PLAN CHECK: $161.00 $161.00 TOTALS:$2,273.21 $2,273.21 Printed: Thursday, October 05, 2023 11:04:22 AM 6 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 FRAMING AOR 9/17/2020 9/17/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 9/16/2020 2:50 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7602753247 e-Mail: jadolan@verizon.net X-RAY ROOM WALLS ONLY. FRAMING JFU 9/22/2020 9/22/2020 NOT READY eTRAKiT Inspection Request 9/21/2020 2:43 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net WORK INCOMPLETE. REINSPECTION FEE ASSESSED. ROUGH ELEC JFU 9/22/2020 9/22/2020 NOT READY eTRAKiT Inspection Request 9/21/2020 2:43 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net WORK INCOMPLETE. REINSPECTION FEE ASSESSED. Printed: Thursday, October 05, 2023 11:04:22 AM 7 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 ROUGH PLBG JFU 9/22/2020 9/22/2020 NOT READY eTRAKiT Inspection Request 9/21/2020 2:43 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net WORK INCOMPLETE. REINSPECTION FEE ASSESSED. ROUGH PLBG AOR 9/24/2020 9/24/2020 NOT READY eTRAKiT Inspection Request 9/23/2020 10:00 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net SEE FRAMING CORRECTIONS. ROUGH ELEC AOR 9/24/2020 9/24/2020 NOT READY eTRAKiT Inspection Request 9/23/2020 10:00 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net SEE FRAMING CORRECTIONS. Printed: Thursday, October 05, 2023 11:04:22 AM 8 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 FRAMING AOR 9/24/2020 9/24/2020 DISAPPROVE D eTRAKiT Inspection Request 9/23/2020 10:00 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net SCOPE OF WORK DOES NOT MATCH APPROVED PLANS, ROUGH MECHANICAL DEMO NOT COMPLETE, ROUGH PLUMBING AS-BUILT DOES NOT COMPLY FOR VERTICAL WET-VENTING, AND ELECTRICAL CLEANUP INCOMPLETE - EOR STRUCTURAL OBSERVATION REQUIRED FOR FRAMING OR RFI REQUIRED TO CLARIFY BRACING ON- CENTER SPACING TO BE USED. -WALLS NOT BRACED PER APPROVED PLANS AND ENGINEER’S STRUCTURAL OBSERVATION -IF CONNECTED TO A SINGLE VERTICAL DRAINAGE PIPE THE SINKS AT THE WASHING AREA AND THE EMPLOYEE AREA MUST BE CONNECTED BACK-TO-BACK WITH AN APPROVED TWO-FIXTURE FITTING AT THE SAME LEVEL PER CPC 704.2 (ALSO THESE SINKS ARE NOT SHOWN ON APPROVED PLAN) -THE VENT CONNECTION OF THE SINK AT THE WASHING AREA IS BELOW THE WEIR OF THE TRAP WHICH IS PROHIBITED BY CPC 905.5 -OBTAIN APPROVAL TO COVER CEILING AREAS FROM FIRE INSPECTOR -ALL FLEXIBLE CONDUIT MUST BE SUPPORTED AND SECURED AT 4½ FT INTERVALS Printed: Thursday, October 05, 2023 11:04:22 AM 9 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 FRAMING JFU 9/29/2020 9/29/2020 DISAPPROVE D -PROVIDE JUNCTION BOXES FOR THE NEW ELECTRICAL LIGHTING (ALSO NOT SHOWN ON APPROVED PLAN, ENERGY COMPLIANCE FORMS AND COMPLIANT LIGHTING CONTROLS MAY BE REQUIRED AS THIS WAS ADDED AFTER THE FACT TO THE SCOPE) -DRYWALL INSTALLED AT VARIOUS LOCATIONS AROUND SINK, WASHER ROOM, ETC PRIOR TO APPROVAL -32” DOOR JAM OPENING WILL NOT PROVIDE THE REQUIRED 32” CLEAR WIDTH ONCE THE DOOR IS INSTALLED ITEMS REQUIRING PLAN REVISION: -ADDED SINKS -ADDED LIGHTING FIXTURES -DOORS REMOVED TO PROVIDE COMPLIANT ACCESSIBLE MANEUVERING CLEARANCES -DELETED SINK AT ROOM #1 -KITCHEN RELOCATION? -WALLS NOT LAID OUT PER PLAN AT KITCHEN/HALLWAY AREA -ANY OTHER ITEMS NOT MATCHING THE APPROVED PLAN ROUGH ELEC JFU 9/29/2020 9/29/2020 DISAPPROVE D eTRAKiT Inspection Request 9/28/2020 11:33 AM J A DOLAN GENERAL CONTRACTOR INC Engineer Letter RE: Framing Received by AJ Ortega 9.28.2020 Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net SEE FRAMING INSPECTION NOTES DATED 9/29/2020. Printed: Thursday, October 05, 2023 11:04:22 AM 10 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 ROUGH PLBG JFU 9/29/2020 9/29/2020 DISAPPROVE D eTRAKiT Inspection Request 9/28/2020 11:33 AM J A DOLAN GENERAL CONTRACTOR INC Engineer Letter RE: Framing Received by AJ Ortega 9.28.2020 Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net SEE FRAMING INSPECTION NOTES DATED 9/29/2020. PREVIOUS CORRECTION UPDATE: 1. [STILL APPLIES] WALLS BRACING CORRECTED BUT WORK IS NOT PARTIALLY APPROVED DUE TO ADDITIONAL WORK BEING PERFORMED AND COVERED – CONTACTOR TO EXPOSE AND CORRECT WORK AS NECESSARY AT OFFICE WINDOW, FRAMED OPENING AT PREVIOUSLY PROPOSED DOOR (K), AND AT FRAMED OPENINGS BETWEEN SUITE 100 TO 200, REINSPECTION REQUIRED PRIOR TO RECOVERING WORK. 2. [STILL APPLIES] WORK CORRECTED AT ONE LOCATION BUT ALSO HAPPENS AT A SIMILARLY DESCRIBED LOCATION, WORK NOT PARTIALLY APPROVED DUE TO WORK STILL BEING REQUIRED - IF CONNECTED TO A SINGLE VERTICAL DRAINAGE PIPE THE SINKS AT THE WASHING AREA AND THE EMPLOYEE AREA MUST BE CONNECTED BACK-TO-BACK WITH AN APPROVED TWO-FIXTURE FITTING AT THE SAME LEVEL PER CPC 704.2 (ALSO THESE SINKS ARE NOT SHOWN ON APPROVED PLAN). 3. [STILL APPLIES] THE VENT CONNECTION OF THE SINK AT THE WASHING AREA IS Printed: Thursday, October 05, 2023 11:04:22 AM 11 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 FRAMING AOR 9/30/2020 9/30/2020 DISAPPROVE D BELOW THE WEIR OF THE TRAP WHICH IS PROHIBITED BY CPC 905.5. 4. [STILL APPLIES] OBTAIN APPROVAL TO COVER CEILING AREAS FROM FIRE INSPECTOR. 5. [STILL APPLIES] ALL FLEXIBLE CONDUIT MUST BE SUPPORTED AND SECURED AT 4½ FT INTERVALS. 6. [STILL APPLIES] PROVIDE JUNCTION BOXES FOR THE NEW ELECTRICAL LIGHTING (ALSO NOT SHOWN ON APPROVED PLAN, ENERGY COMPLIANCE FORMS AND COMPLIANT LIGHTING CONTROLS MAY BE REQUIRED AS THIS WAS ADDED AFTER THE FACT TO THE SCOPE) 7. [STILL APPLIES] DRYWALL INSTALLED AT VARIOUS LOCATIONS AROUND SINK, WASHER ROOM, ETC PRIOR TO APPROVAL – AREA NOTED HAS BEEN EXPOSED FOR INSPECTION BUT OTHERS AREAS ARE STILL BEING COVERED PRIOR TO INSPECTION, SEE ITEM 1. 8. [STILL APPLIES] 32” DOOR JAM OPENING WILL NOT PROVIDE THE REQUIRED 32” CLEAR WIDTH ONCE THE DOOR IS INSTALLED – FRAMING COVERED PRIOR TO INSPECTION, SEE ITEM 1. 9. [ADDED] DOOR MANEUVERING CLEARANCE AT DOOR (A) NOT PROVIDED BY THE EXISTING FRAMING, ADDITIONALLY WORK IN THIS AREA HAS CHANGED AND NOT PER THE APPROVED PLAN – CONTRACTOR TO EITHER REMOVE DOOR OR PROVIDE PROPER CLEARANCES, REINSPECTION REQUIRED PRIOR TO RECOVERING WORK. 10. [ADDED] STORAGE AREA WAS ORIGINALLY GOING TO BE ENLARGED AND FRAMING WAS REMOVED, THAT WORK HAS Printed: Thursday, October 05, 2023 11:04:22 AM 12 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 SINCE CHANGED AND WALL IS TO REMAIN, RFI FROM EOR REQUIRED FOR REPLACING OF STEEL STUDS WHERE THEY HAD ALREADY BEEN REMOVED. [STILL APPLIES] ITEMS REQUIRING PLAN REVISION: -ADDED SINKS -ADDED LIGHTING FIXTURES -DOORS REMOVED TO PROVIDE COMPLIANT ACCESSIBLE MANEUVERING CLEARANCES -DELETED SINK AT ROOM #1 -KITCHEN RELOCATION? -WALLS NOT LAID OUT PER PLAN AT KITCHEN/HALLWAY AREA -ANY OTHER ITEMS NOT MATCHING THE APPROVED PLAN ROUGH PLBG AOR 10/12/2020 10/12/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 10/9/2020 9:59 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net EXAM AND WASHING AREAS ONLY, DOES NOT INCLUDE WORK AREA WHERE WASHING MACHINE AND WATER HEATER HAVE BEEN INSTALLED, ALL OTHER AREAS ARE STATED AS EXISTING. THIS APPROVAL IS NOT FOR INSTALLATION OF FIXTURES DEMONSTRATING ACCESSIBILITY COMPLIANCE, THAT WILL BE INSPECTED AT FINAL INSPECTION. Printed: Thursday, October 05, 2023 11:04:22 AM 13 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 FRAMING AOR 10/12/2020 10/12/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 10/9/2020 9:59 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net WALLS ONLY WITH EXCEPTION OF WORK AREA THAT NEEDS TO BE EXPOSED DUE TO COVERING PRIOR INSPECTION AT WASHER AND FRAMED OPENING TO OFFICE 9, AND THE DOOR WAY TO OFFICE 4 NEEDS TO BE RAISED TO MEET THE 80" HEIGHT REQUIREMENT OF CBC 1010.1.1. ROUGH ELEC AOR 10/12/2020 10/12/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 10/9/2020 9:59 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net WALLS ONLY WITH EXCEPTION OF NEWLY EXPOSED AREAS AT FRAMED OPENING TO OFFICE 9, ELECTRICAL BRANCH CIRCUIT WAS FOUND THAT WAS NOT TERMINATED AT AN ACCESSIBLE JUNCTION BOX AND LIGHTSWITCH MOUNTED AT A HEIGHT EXCEEDING 44” OVER AN OBSTRUCTION NEEDS TO BE RELOCATED TO COMPLY WITH CBC 11B-308. REINSPECTION OF THE NOTED AREA AND OVERHEAD/TBAR AREAS ARE THE ONLY REMAINING ITEMS REQUIRED TO BE INSPECTED WITHIN THE SCOPE OF WORK. Printed: Thursday, October 05, 2023 11:04:22 AM 14 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 GAS LINE/TEST AOR 10/13/2020 10/13/2020 APPROVED eTRAKiT Inspection Request 10/12/2020 12:53 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net SERVICE TO WATER HEATER AND DRYER ONLY. DRYWALL NAIL AOR 10/13/2020 10/13/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 10/12/2020 12:53 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net WALLS ONLY. FRAMING AOR 10/13/2020 10/13/2020 APPROVED W/EXCEPTIO N PREVIOUS INSPECTION COMMENTS RESOLVED, ONLY PENDING ITEM IS FOR CEILING RECEIVING INSPECTION FROM FIRE INSPECTOR FOR OKAY TO COVER. ROUGH PLBG AOR 10/14/2020 10/14/2020 APPROVED eTRAKiT Inspection Request 10/13/2020 2:30 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net Printed: Thursday, October 05, 2023 11:04:22 AM 15 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 ROUGH PLBG AOR 10/14/2020 10/14/2020 APPROVED eTRAKiT Inspection Request WASHER AND SINK DRAIN PIPE CONNECTION ONLY, ALL AREAS EXPOSED AND WITHIN THE SCOPE OF WORK NOW COMPLETE. OVERHEAD ROUGH PIPING KHET 10/19/2020 10/19/2020 APPROVED OKAY TO COVER DRYWALL NAIL JFU 10/20/2020 10/20/2020 APPROVED REMAINDER OF AREAS. T-BAR/OVERHEAD AOR 10/21/2020 10/21/2020 APPROVED T/I FINAL KHET 10/29/2020 10/29/2020 DISAPPROVE D CORRECTIONS IN ATTACHMENTS FINAL**AOR 10/29/2020 10/29/2020 DISAPPROVE D eTRAKiT Inspection Request 10/28/2020 1:52 PM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net CORRECTIONS: -SINK HEIGHT, KNEE CLEARANCE AND DISTANCE FROM SIDE WALL NOT PROVIDED AT VARIOUS LOCATIONS. -GFCI PROTECTION REQUIRED FOR RECEPTACLES WITHIN SIX (6) FEET OF SINKS. -FIRE DEPARTMENT FINAL REQUIRED. -PATH OF TRAVEL UPGRADES NOT COMPLETE, NOR ACCURATELY REPRESENT THE COST OF THE WORK INVOLVED - CONTRACTOR AND ARCHITECT TO REVISE. -SEE BCOM2020-0026, TWO PERMITS ISSUED FOR ONE OVERALL TI, REQUIRED TO BE COMPLETED CONCURRENTLY. T/I FINAL KHET 11/3/2020 11/3/2020 APPROVED All items corrected. Fire clearance granted. Printed: Thursday, October 05, 2023 11:04:22 AM 16 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 FINAL**JFU 11/3/2020 11/3/2020 DISAPPROVE D eTRAKiT Inspection Request 11/2/2020 8:15 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net -PROVIDE A MAXIMUM HEIGHT OF 34” TO THE RIM OF THE SINKS AT THE RESTROOM AND THE EMPLOYEE AREA -PROVIDE PROTECTION FOR THE UNDERSINK PIPING AT THE -INSTALL THE VENT AT THE WATER HEATER -INSTALL THE DRYER VENT AND CONNECT TO THE OUTDOORS—PROVIDE BACKDRAFT DAMPER AND ENSURE TERMINATION IS 3’ FROM OPENINGS TO THE BUILDING AND 10’ FROM A FORCED AIR INLET -REPLACE THE “VAN ACCESSIBLE” PARKING SIGNAGE WITH STANDARD PARKING SPACE SIGNAGE FINAL**AOR 11/5/2020 11/5/2020 APPROVED eTRAKiT Inspection Request 11/4/2020 9:07 AM J A DOLAN GENERAL CONTRACTOR INC Contact Name: J A DOLAN GENERAL CONTRACTOR INC Site Address: 78555 HIGHWAY 111 STE 200 Phone: 7603400905 e-Mail: jadolan@verizon.net REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES PARENT PROJECTS Printed: Thursday, October 05, 2023 11:04:22 AM 17 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 DATE 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 1/23/2020 1/24/2020 1/27/2020 COMPLETE 1ST PLANNING (1 WK) CARLOS FLORES 1/23/2020 1/30/2020 1/30/2020 REVISIONS REQUIRED PROVIDE SQUARE FOOTAGE OF TENANT SPACE. BASED ON SQUARE FOOTAGE, COVERED PARKING SPACES MAY BE REQUIRED 1ST FIRE (1 WK)KOHL HETRICK 1/23/2020 1/30/2020 2/7/2020 REVISIONS REQUIRED SEE NOTES OFFICE OF THE FIRE MARSHAL - 1ST REVIEW CORRECTIONS: 1) E1, M1 and P1 sheets were not provided with the submittal. 2) Provide the following details on the title/cover page: a) Building/Tenant area analysis b) Occupancy Classification and Calculation c) Type of Construction d) Fire Sprinkler (Yes/No) 3) Identify deferred submittals to be provided: (Fire Sprinkler Adjustments) 4)Identify size, location and installation method of portable fire extinguishers. 5) Clarify the scope of patient care involved with the medical practice and the use of the Surgery room. a) Is anesthesia involved? b) Can the patient maintain self-preservation? Printed: Thursday, October 05, 2023 11:04:22 AM 18 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 1ST FIRE (1 WK)KOHL HETRICK 1/23/2020 1/30/2020 2/7/2020 REVISIONS REQUIRED SEE NOTES OFFICE OF THE FIRE MARSHAL - 1ST REVIEW CORRECTIONS: 1) E1, M1 and P1 sheets were not provided with the submittal. 2) Provide the following details on the title/cover page: a) Building/Tenant area analysis b) Occupancy Classification and Calculation c) Type of Construction d) Fire Sprinkler (Yes/No) 3) Identify deferred submittals to be provided: (Fire Sprinkler Adjustments) 4)Identify size, location and installation method of portable fire extinguishers. 5) Clarify the scope of patient care involved with the medical practice and the use of the Surgery room. a) Is anesthesia involved? b) Can the patient maintain self-preservation? 1ST BLDG NS (1 WK)AJ ORTEGA 1/23/2020 1/30/2020 2/21/2020 PENDING DOCUMENTS SEE CHRONOLOGY 2ND BLDG NS (1 WK)JAKE FUSON 3/5/2020 3/12/2020 3/23/2020 REVISIONS REQUIRED A DIGITAL PLAN SET HAS BEEN ATTACHED TO THIS PERMIT SEE 1ST REVIEW - CORRECTION LIST. 2ND PLANNING (1 WK) CARLOS FLORES 3/5/2020 3/12/2020 3/12/2020 READY FOR APPROVAL DIGITAL PLAN SET HAS BEEN ATTACHED FIRE GENERAL CONDITIONS Fire Department approval is based upon the 2019 CBC requirements for B Occupancies with an occupant load of 25. It is prohibited to use, process or store any materials in the occupancy that would classify it as a Group H occupancy, Printed: Thursday, October 05, 2023 11:04:22 AM 19 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 2ND FIRE (1 WK)KOHL HETRICK 3/5/2020 3/12/2020 3/18/2020 READY FOR APPROVAL SEE NOTES FOR CONDITIONS without further review and approval. DEFERRED SUBMITTALS REQUIRED 1) FIRE SPRINKLER – Tenant Improvement plans must be submitted and reference the installing contractor performing the work. Permit fees will be required. PRIOR TO FINAL INSPECTION 1) Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. 2) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. Building address numbers shall be a minimum of 12”. Minimum 6” tall suite addressing shall be provided to both the front and rear entrances. All addressing must be legible and of a contrasting color with the to be visible from the street at all hours. 3) Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. All new and existing portable fire extinguishers shall have current annual servicing performed and tagged. 4) A durable sign stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" shall be placed on or adjacent to the front exit doors. The sign shall be in letters not less than one inch high on a contrasting background (A <300, B, F, M and S). 5) Illuminated Exit Signage and Egress Illumination placement and functional test will be witnessed by OFM Fire Inspector at time of final inspection. The Fire Department approved plans and conditions letter must be at the job site. Printed: Thursday, October 05, 2023 11:04:22 AM 20 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/17/2020 ARMANDO MAGALLON 2ND SUBMITTAL - PLAN SET (DIGITAL)BCOM2020-0004.pdf 0 BOND INFORMATION Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. 3RD BLDG NS – ETRAKIT (1 WK)JAKE FUSON 4/20/2020 4/27/2020 4/27/2020 REVISIONS REQUIRED SEE 3RD REVIEW CORRECTION LIST. 4TH BLDG NS (1 WK)JAKE FUSON 5/8/2020 5/15/2020 5/14/2020 REVISIONS REQUIRED -PATH OF TRAVEL UPGRADE FORM IS NOT APPROVABLE AS THE COSTS OF NEW CONSTRUCTION ARE USED TO JUSTIFY THE PATH OF TRAVEL UPGRADE REQUIREMENT. P.O.T. UPGRADES ARE LIMITED TO WORK ON EXISTING FEATURES TO BRING THEM INTO COMPLIANCE. -REVISE DIMENSION ON 14/ADA2 TO READ 36" MINIMUM RATHER THAN MAXIMUM 5TH BLDG NS (1 WK)JAKE FUSON 6/10/2020 6/17/2020 6/11/2020 APPROVED 1ST BLDG NS - ETRAKIT (1 WK)AJ ORTEGA 9/2/2020 9/10/2020 9/9/2020 APPROVED REVISION 1: STEEL FRAMING REVISION 1: STEEL STUD AND CEILING JOIST FRAMING AND DESIGN DETAILING. 1ST BLDG NS - ETRAKIT (1 DAY)JAKE FUSON 10/7/2020 10/8/2020 10/8/2020 APPROVED REVISION 2 - FIELD CHANGES REVISION 2 - FIELD CHANGES - REVISED LAYOUT, UPDATED SINK LOCATIONS + LIGHT FIXTURE REPLACEMENTS. 1ST BLDG NS - ETRAKIT (1 DAY)AJ ORTEGA 11/2/2020 11/3/2020 11/2/2020 APPROVED REVISION 3 - PATH OF TRAVEL REVISION 3 - PATH OF TRAVEL DETERMINATION UPDATED BASED ON FURTHER REVIEW OF DEFICIENCIES, SEE ATTACHED FORM DATED 11/2/2020 (REVISION 4 OVERALL TO THE FORM). Printed: Thursday, October 05, 2023 11:04:22 AM 21 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/9/2020 AJ ORTEGA INVOICE 1693 (REVISION 1 STRUCTURAL DESIGN) BCOM2020-0004 - INVOICE 1693 (REVISION 1 STRUCTURAL DESIGN).pdf 1 DOC 9/9/2020 AJ ORTEGA STRUCTURAL CALCULATIONS (APPROVED) BCOM2020-0004 - STRUCTURAL CALCULATIONS (APPROVED).pdf 1 DOC 9/28/2020 AJ ORTEGA STRUCTURAL OBSERVATION (CEILING FRAMING) BCOM2020-0004 - STRUCTURAL OBSERVATION (CEILING FRAMING).pdf 1 DOC 11/2/2020 AJ ORTEGA REVISION 3 - PATH OF TRAVEL FORM WITH SCOPE OF WORK (APPROVED) BCOM2020-0004 - REVISION 3 - PATH OF TRAVEL FORM WITH SCOPE OF WORK (APPROVED).pdf 1 DOC 4/16/2020 EtrakitContractor 3RD SUBMITTAL PLAN SET BCOM2020-0004 - 3RD SUBMITTAL PLAN SET.pdf 1 DOC 6/10/2020 EtrakitContractor 5TH SUBMITTAL PLAN SET 000 4TH SUBMITTAL.pdf 1 DOC 10/7/2020 EtrakitContractor REVISION 2 - SURGICAL LIGHT SPECIFICATION (2 OF 2) LQ Pet, 07-890-9340 _ Single Ceiling Mount _ STARLED3 NX Surgical Light (1), 10.6.2020.pdf 1 DOC 10/7/2020 EtrakitContractor REVISION 2 - SURGICAL LIGHT SPECIFICATION (1 OF 2) LQ Pet, 07-890-9341 _ Twin Ceiling Mount _ STARLED3 NX Surgical Light, 10.6.2020.pdf 1 Printed: Thursday, October 05, 2023 11:04:22 AM 22 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/7/2020 EtrakitContractor Architect's Reflected Ceiling Plan, 10.6.2020 LQ Pet Hospital, A2.0-AS BUILT, 10.6.2020.pdf 1 DOC 10/7/2020 EtrakitContractor Architect's Floor Plan, 10.6.2020 LQ Pet Hospital, A3.0 - AS BUILT, 10.6.2020.pdf 1 DOC 3/24/2020 JAKE FUSON 1ST REVIEW - CORRECTION LIST BCOM2020-0004 - 1ST REVIEW - CORRECTION LIST.pdf 1 DOC 4/27/2020 JAKE FUSON 2ND REVIEW - CORRECTION LIST BCOM2020-0004 - 1ST REVIEW - CORRECTION LIST_1.pdf 1 DOC 4/27/2020 JAKE FUSON 3RD REVIEW CORRECTION LIST BCOM2020-0004 - 3RD REVIEW CORRECTION LIST.pdf 1 DOC 5/8/2020 JAKE FUSON 4TH SUBMITTAL CORRECTION RESPONSES BCOM2020-0004 - 4TH SUBMITTAL CORRECTION RESPONSES.pdf 1 DOC 5/8/2020 JAKE FUSON 4TH SUBMITTAL PLAN SET BCOM2020-0004 - 4TH SUBMITTAL PLAN SET.pdf 1 DOC 6/11/2020 JAKE FUSON PATH OF TRAVEL UPGRADE DETERMINATION PATH OF TRAVEL UPGRADE DETERMINATION.pdf 1 DOC 6/11/2020 JAKE FUSON APPROVED PLAN SET BCOM2020-0004 - APPROVED PLAN SET.pdf 1 DOC 10/8/2020 JAKE FUSON REVISION 2 - APPROVED PLAN BCOM2020-0004 - REVISION 2 - APPROVED PLAN .pdf 1 Printed: Thursday, October 05, 2023 11:04:22 AM 23 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/8/2020 JAKE FUSON RFI - SURGICAL LIGHT ATTACHMENT DETAILING BCOM2020-0004 - RFI - SURGICAL LIGHT ATTACHMENT DETAILING.pdf 1 DOC 10/29/2020 KOHL HETRICK BCOM2020-0004 - LQ PET HOSPITAL - 10-29- 2020 FLAT.pdf BCOM2020-0004 - LQ PET HOSPITAL - 10-29- 2020 FLAT.pdf 1 Printed: Thursday, October 05, 2023 11:04:22 AM 24 of 24 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0004 78-495 Calle Tampico, La Quinta CA 92253 Main: 760-777-7000 Direct: 760-777-7074 PAGE _____ OF _____ PERMIT/CASE#: NOTICE NO: FACILITY NAME: DATE: FACILITY ADDRESS: CONTACT: The items below are in violation of or shall meet additional requirements of one or more of the following: CALIFORNIA FIRE CODE __________________ NFPA STD. ______________ CALIFORNIA BUILDING CODE _____________ CCR TITLE ______________ LA QUINTA MUNICIPAL CODE _____________ OTHER ________________ The listed violations/requirements shall be corrected immediately. A re-inspection will be conducted on or after ______________________________ 20____. FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL. Received By: __________________________________ Signature: _______________________________________ Fire Inspector: _________________________________ Radio I.D.: _______________________________________ IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074. BCOM2020-0004 LQ Pet Hospital 1 10/29/2020 JOE DOLAN dolanoffice@gmail.com 1) Service, maintain emergency exit signs and emergency egress lighting 2) Portable fire extinguishers shall be mounted and provided with date of purchase receipts 3) Outlet cover plates throughout 4) Update electrical panel schedules 5) Electrical Room rated penetrations maintained 6) RISER ROOM, FACP signage. 7) Remove storage from electrical room. FINAL TI INSPECTION JOE DOLAN I-630