Loading...
FSS2022-0391ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 10/27/2022 10/27/2022 Regarding the above permit. The permit is on hold as the Dwelling permit has not been approved yet. When the dwelling permit has been issued please reply to this email and we can set the reviews. Also a contractor must have a contracot account. To have an account a city business license is required. I have attached the application. Once complete return to lqlb@laquintaca.gov for processing. And we can send a link for payment. Please include a copy of the owners ID and be sure to complete question 5 with the SIC code. Once you have your business license. Let me know and I will add your information to FSS2022-0391. CONDITIONS Description: Gilbert Garage Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: ISSUED Applied: 10/27/2022 EPRS Parcel No: 767770028 Site Address: 81740 MERV GRIFFIN WY LA QUINTA,CA 92253 Approved: 12/18/2022 RWI Subdivision: TR 32879 Block: Lot: 21 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $2,975.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, July 19, 2023 4:12:28 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0391 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT AFP Systems 19435 SW 129th Ave Tualatin OR 97062 (503)692-9284 permits@afpsys.com CONTRACTOR AFP Systems, Inc 19435 SW 129th Ave Tualatin or 97062 (503)692-9284 permits@afpsys.com OWNER John Gilbert 81740 Merv Griffin La Quinta Ca 92253 (503)692-9284 INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 12/19/22 WEB13861 772814691 CREDIT AFP Systems EPRS FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 12/19/22 WEB13861 772814691 CREDIT AFP Systems EPRS Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 12/19/22 WEB13861 772814691 CREDIT AFP Systems EPRS Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 12/19/22 WEB13861 772814691 CREDIT AFP Systems EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$436.00 $436.00 Printed: Wednesday, July 19, 2023 4:12:28 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0391 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/27/2022 Etrakit Public Registration Plans FP01.pdf 1 DOC 10/27/2022 Etrakit Public Registration Material Data Material Data Cali.pdf 1 DOC 10/27/2022 Etrakit Public Registration Hydraulic Calcs Calcs..PDF 1 DOC 10/27/2022 Etrakit Public Registration PSI PSI Request.pdf 1 DOC 12/18/2022 REBECCA WINSCOTT LQ FSS2022-0391.pdf COA LQ FSS2022-0391.pdf 1 DOC 12/18/2022 REBECCA WINSCOTT LQ FSS2022-0391 Gilbert Garage APPROVED.pdf LQ FSS2022-0391 Gilbert Garage APPROVED.pdf 1 BOND INFORMATION 1ST PERMIT TECH – ETRAKIT (1 DAY) AARON HICKSON 10/27/2022 10/28/2022 10/27/2022 COMPLETE DWELLING NEEDS TO BE ISSUED FIRST 1ST FIRE - ETRAKIT (2 WK) REBECCA WINSCOTT 11/20/2022 12/5/2022 12/18/2022 APPROVED Printed: Wednesday, July 19, 2023 4:12:28 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0391 Hydraulic Calculations Location: , , Project Name: Drawing1 Drawing Name: FP01.cad Calculation Date: 10/27/2022 for Design Residential Area of Application: 900 ft² (Actual 237 ft²) Coverage per Sprinkler: 256 ft² Type of sprinklers calculated: 2 Remote Area Number: Occupancy Classification: No. of sprinklers calculated: Density 0.05 gpm/ft² Pendent No. of nozzles calculated: 0 In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 10.0 gpm (including Hose Streams where applicable):Total Water Required 43.133@26.27From Water Supply at Node 1:(Safety Margin = 34.265) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent System:N/A Name of Contractor: Authority Having Jurisdiction: Address: Phone Number: Name of designer: , N/A N/A Right:Left:Automatic peaking results Notes: 10/27/2022© M.E.P.CAD, Inc.Page 1AutoSPRINK 2022 v17.1.13.0 2:54:44PM Hydraulic Graph Water Supply Node: 1 Job Name: Drawing1 Remote Area Number: Date: 10/27/2022 Summary Sheet N 1.85 © M.E.P.CAD, Inc.10/27/2022 Page 2AutoSPRINK 2022 v17.1.13.0 2:54:47PM Job Name: Drawing1 Remote Area Number: Date: 10/27/2022 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 60.0001 43.13326.27100.00 77.39879.000Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number -3'-0 26.2743.133Supply1 10'-0 13.007.039Sprinkler204 10'-0 13.277.335Sprinkler209 10'-6 7.53722 1'-1 19.662Supply31 1'-5 18.35432 3'-3½17.365Gauge34 © M.E.P.CAD, Inc.10/27/2022 Page 3AutoSPRINK 2022 v17.1.13.0 2:54:52PM Date: 10/27/2022 Job Name: Drawing1 Remote Area Number: Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 12'-0 10'-6 23'-4 -0.217 0.715 10'-0 11'-4204 22 1 • • • • • Route 1 • • • • •(See Notes) 1.1010 7.03913.00 0.030666 Sprinkler, 13.00 4.9 E(7'-0), T(5'-0) 150 16'-0 3'-3½59'-5½ 3.127 6.701 10'-6 43'-5½22 34 1 (See Notes) 1.1010 7.53713.27 0.112688 Flow (q) from Route 2 26.27 4Tr(1'-0), T(5'-0), E(7'-0), BOR, f(-0.000) 150 1'-5 1'-8 0.804 0.186 3'-3½1'-834 32 1 (See Notes) 1.1010 17.365 0.11268826.27 BalV 150 5'-0 1'-1 5'-4½ 0.154 1.154 1'-5 0'-4½32 31 1 (See Notes) 1.0490 18.354 0.21552126.27 sCV(5'-0) 120 21'-0 -3'-0 178'-1½ 1.769 21.702 1'-1 157'-1½31 1 1 (See Notes) 1.1010 19.662 0.11268826.27 3E(7'-0), WMV(-1.630), S 150 1 0.00 Hose Allowance At Source 26.27 Route 1Total(Pt) 43.133 12'-0 10'-6 13'-2 -0.217 0.419 10'-0 1'-2209 22 1 • • • • • Route 2 • • • • •(See Notes) 1.1010 7.33513.27 0.031857 Sprinkler, 13.27 4.9 E(7'-0), T(5'-0) 150 7.537 Total(Pt)Route 2 © M.E.P.CAD, Inc.10/27/2022 Page 4AutoSPRINK 2022 v17.1.13.0 2:54:56PM Date: 10/27/2022 Job Name: Drawing1 Remote Area Number: Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/27/2022 Page 5AutoSPRINK 2022 v17.1.13.0 2:54:56PM OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 18, 2022 AFP Systems Re: Residential Fire Sprinkler Plan Review – Gilbert Garage FSS2022-0391 / 81740 Merv Griffin Way The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Rebecca Winscott - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 81740 Merv Griffin Way PERMIT#: FSS2022-0391 DATE ISSUED: 121822 DESCRIPTION: Gilbert Garage CONTRACTOR: AFP Systems HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. PERMIT INSPECTION HISTORY REPORT (FSS2022-0391) FOR CITY OF LA QUINTA Fire Sprinkler System - Residential - 13D 10/27/2022Application Date:Permit Type:767770028Parcel Fire - Custom Home 01/05/2024Work Class:Issue Date:81740 MERV GRIFFIN WY LA QUINTA, CA 92253 Address: Finaled 10/02/2024Expiration Date:Status:Description:Gilbert Garage *** Owner:Contractor:Applicant:John Gilbert AFP Systems, Inc A F P SYSTEMS INC Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date 01/08/2024 01/08/2024 FIRE - OH Hydro (Res) ISPRK-010866-202 4 Approved Chris Cox No Complete COMMENTS ApprovedChecklist Item 01/08/2024 FIRE - OH Rough Piping (RES) ISPRK-010865-202 4 Approved Chris Cox No Complete COMMENTS ApprovedChecklist Item 04/05/2024 04/05/2024 Fire Sprinkler Final 13D ISPRK-017448-202 4 Disapproved (with fee) Leilani Rojas Yes Complete COMMENTS ApprovedChecklist Item Fire Sprinkler Type(s)LOW PSI LEVELS, 5 PSI.No Sprinkler Head Trim and Cover Plates LOW PSI LEVELS, 5 PSI.No Water Meter Verification LOW PSI LEVELS, 5 PSI.No Fire Riser Assembly and Accessibility LOW PSI LEVELS, 5 PSI.No Fire Final LOW PSI LEVELS, 5 PSI.No 05/01/2024 05/01/2024 Fire Sprinkler Final 13D ISPRK-019397-202 4 Disapproved Lucero Iniguez Yes Complete COMMENTS ApprovedChecklist Item Fire Final SPRINKLER HEAD OBSTRUCTED BY CEILING FAN No 05/02/2024 05/02/2024 Fire Sprinkler Final 13D ISPRK-019611-202 4 Approved Lucero Iniguez No Complete Reinspection of ISPRK-019397-2024 COMMENTS ApprovedChecklist Item Fire Final SPRINKLER HEAD OBSTRUCTED BY CEILING FAN 050224 - REINSPECTION CONDUCTED - APPROVED Yes 78-495 Calle Tampico Page 1 of 1October 11, 2024