E-MAIL DUANE CLAYTON 9/2/2022 9/2/2022 - NOTIFIED APPLICANT THAT PLAN REVIEW IS COMPLETE
AND APPROVED.
CONDITIONS
Description: ASHER / POOL, SPAS (2) AND GAS OUTLET AT REAR YARD
Type: POOL CONSTRUCTION
(WEB)
Subtype: PRIVATE Status: FINALED Applied: 8/24/2022 ECON
Parcel No: 767680028 Site Address: 81370 PEARY PL LA QUINTA,CA 92253 Approved: 9/2/2022 DCL
Subdivision: TR 33076-1 Block: Lot: 66 Issued: 9/2/2022 ONLINE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/4/2023 DCL
Valuation: $250,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: POOL, SPA AND GAS OUTLET (1) AT REAR YARD, WITH SPA AT SIDE YARD [POOL ENGINEERING]. APPROVED SITE PLAN AND
ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND
BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
Printed: Thursday, October 19, 2023 2:55:19 PM 1 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0350
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
BSAS SB1473 FEE 101-0000-20306 0 $10.00 $10.00 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $10.00 $10.00
DEVICES, FIRST 20 101-0000-42403 0 $27.79 $27.79 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
DEVICES, FIRST 20 PC 101-0000-42600 0 $27.79 $27.79 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
Total Paid for ELECTRICAL 2021: $55.58 $55.58
DETACHED SPA/WATER
FEATURE/OTHER 101-0000-42404 0 $208.41 $208.41 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
SWIMMING
POOL/SPA/WATER
FEATURE
101-0000-42404 0 $208.41 $208.41 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
SWIMMING
POOL/SPA/WATER
FEATURE PC
101-0000-42600 0 $113.38 $113.38 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
Total Paid for POOL / SPA 2021: $530.20 $530.20
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 9/2/22 WEB12954 717807967 CREDIT 820132 ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$611.78 $611.78
Printed: Thursday, October 19, 2023 2:55:19 PM 2 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0350
PRE-GUNITE DCL 9/15/2022 9/15/2022 PARTIALLY
APPROVED
eTRAKiT Inspection
Request
9/14/2022 11:09 AM F P D SERVICES INC
DBA STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
- EXCLUDES SIDE YARD SPA.
UNDERGROUND PLBG JAN 9/19/2022 9/19/2022 PARTIALLY
APPROVED
eTRAKiT Inspection
Request
9/16/2022 9:43 AM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
-SPA AT WEST SIDE YARD ONLY
UNDERGROUND GAS JAN 9/19/2022 9/19/2022 APPROVED eTRAKiT Inspection
Request
9/16/2022 9:43 AM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
Printed: Thursday, October 19, 2023 2:55:19 PM 3 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0350
UNDERGROUND ELEC JAN 9/19/2022 9/19/2022 PARTIALLY
APPROVED
eTRAKiT Inspection
Request
9/16/2022 9:43 AM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
-SPA AT WEST SIDE YARD ONLY
PRE-GUNITE JAN 9/19/2022 9/19/2022 PARTIALLY
APPROVED
eTRAKiT Inspection
Request
9/16/2022 9:43 AM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
Spa at west side yard only
DECK BOND BLAK 1/12/2023 1/12/2023 PARTIALLY
APPROVED
eTRAKiT Inspection
Request
1/11/2023 10:17 AM F P D SERVICES INC
DBA STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
OK to proceed with pour of concrete at the
spa area. Verified for bonding points number
eight and tied to the rebar. Only spa.
Printed: Thursday, October 19, 2023 2:55:19 PM 4 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0350
DECK BOND BLAK 1/18/2023 1/18/2023 PARTIALLY
APPROVED
eTRAKiT Inspection
Request
1/17/2023 3:13 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
Verified five points of bonding at back pool.
OK to proceed with flat work.
Verified five points of bonding around pool
OK to proceed with flat work.
PRE-PLASTER BLAK 2/21/2023 2/21/2023 APPROVED eTRAKiT Inspection
Request
2/17/2023 12:30 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
FINAL**DCL 5/2/2023 5/2/2023 DISAPPROVE
D
eTRAKiT Inspection
Request
5/1/2023 2:09 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
- NUMBER SIX BLACK WIRE NOT PERMITTED
TO BE REIDENTIFIED (TAPED GREEN) AS
NON-CURRENT CARRYING
(GREEN/GROUND). SEE SPA AND POOL SUB
PANELS.
Printed: Thursday, October 19, 2023 2:55:19 PM 5 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0350
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 9/2/2022 DUANE CLAYTON PLAN SET (APPROVED)BPOL2022-0350 - PLAN
SET (APPROVED) CF.pdf 1
DOC 8/24/2022 Etrakit Contractor 1ST SUBMITTAL - PLAN
SET
Lot
66_POOL_SPA_0824.pdf 1
BOND INFORMATION
FINAL**DCL 5/4/2023 5/4/2023 APPROVED eTRAKiT Inspection
Request
5/3/2023 1:45 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 81370 PEARY PL
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST BLDG NS -
ETRAKIT (1 DAY)
DUANE
CLAYTON
8/24/2022 8/25/2022 9/2/2022 APPROVED - SEE APPROVED PLAN SET IN ATTACHMENTS.
PARENT PROJECTS
Printed: Thursday, October 19, 2023 2:55:19 PM 6 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0350
AVENUE 54
BAFFIN AVE.ROSS AVE.F
R
E
M
O
N
T
W
A
Y
PIKE PL.PEARLY PL.MONROE STMADISON STAVENUE 52
COLUMBIA WAY
AMUN
DS
O
N AVE.
SITE MERIWETHER WAYHUMBOLDT BLVDMERIWETHER WAYHUMBOLDT BLVDROSS
A
V
E.
ELS
W
O
R
T
H
DE S
O
T
OSHACKLETON
SHEET INDEXVICINITY MAP
CUSTOM POOL AND SPA
FOR
ASHER LOT 66
81370 PEARLY PLACE
LA QUINTA, CA 92253
GENERAL NOTES
TITLE
SP-1.0 COVER SHEET
SP-2.0 SITE PLAN
SP-3.0 ENLARGED POOL/SPA PLAN
SP-3.1 SECTIONS & DETAILS
SP-3.2 MASTER SPA & EQUIPMENT LAYOUT
S1 ENGINEERING DETAIL 100
S2 ENGINEERING DETAIL 649
NO.
ABBREVIATIONS REFERENCE SYMBOLS CITY OF LA QUINTA NOTES
100'-0"
F.F. ELEV.
GRIDLINE
ELEVATION MARKER
DETAIL CALLOUT
SECTION CUTSHEET
NO
SHEET
NO
14 MATERIAL KEYNOTE
CONCRETE
GRAVEL
EARTH
WOOD FINISH
CONCRETE MASONRY UNIT
STONE
GUNITE
WATER (SURFACE)
WATER (SECTION)
1
ELEVATION CALLOUTSHEET
NO
IFINISH KEYNOTE
GRASS
F-1
POOL LIGHT
POOL DRAIN
SPILL
MAIN DRAIN SUCTION - 3' MIN. SEPARATION
UMBRELLA SLEEVE
POOL RETURN
SKIMMER
AUTO FILL
DECK JET
AQUASTAR 4" FLOOR RETURN BLACK
VACUUM PORT W/ VACUUM LOCK
J
01 POOL EQUIPMENT TAG
GENERAL NOTES:
1. PROPOSED CONSTRUCTION WILL CONFORM TO THE CURRENT CODES (CBC 106.1.1)
2019 California Residential Code, Title 24 Part 2.5
2019 California Electrical Code, Title 24 Part 3
2019 California Mechanical Code, Title 24 Part 4
2019 California Plumbing Code, Title 24 Part 5
2019 California Energy Code, Title 24 Part 6
2019 California Fire Code, Title 24 Part 9
2. GOVERNMENT CODE SECTION 4216.2. (A) (1) EXCEPT IN AN EMERGENCY, ANY PERSON
PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE
REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE
THAN 14 CALENDAR DAYS, PRIOR TO COMMENCING THAT EXCAVATION, IF THE
EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY
SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE
UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND, IF
PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER
SUITABLE MARKINGS THE AREA TO BE EXCAVATED.
3. THE CITY BUILDING INSPECTOR HAS THE AUTHORITY TO REQUEST FULLY REVISED
PLAN SHEETS WITH ALL FIELD CHANGES CLOUDED WITH DELTAS TO BE SUBMITTED
FOR CITY PLAN REVIEW WHEN HE/SHE DETERMINES THE NUMBER OF FIELD
REVISIONS WARRANT SUCH A REQUEST.
ELECTRICAL NOTES:
1. THE EQUIPMENT BONDING GRID SHALL EXTEND UNDER PAVED AND UNPAVED
SURFACES FOR 3 FEET HORIZONTALLY BEYOND THE INSIDE WALLS OF THE POOL.
2. ALL METAL-SHEATHED CABLES AND RACEWAYS, METAL PIPING, AND ALL FIXED METAL
PARTS THAT ARE WITHIN THE FOLLOWING DISTANCES OF THE POOL, EXCEPT
THOSE SEPARATED FROM THE POOL BY A PERMANENT BARRIER, SHALL BE
BONDED:
A.) WITHIN 5 FEET HORIZONTALLY OF THE INSIDE WALLS OF THE POOL.
B.) WITHIN 12 FEET MEASURED VERTICALLY ABOVE THE MAXIMUM WATER LEVEL OF
THE POOL, OR ANY SLIDES, DIVING BOARDS ETC...
3. PROVIDE 36" WORKING CLEARANCES FOR THE POOL EQUIPMENT DISCONNECT AND
SUB PANEL (CEC ART 110.26)
4. LOAD CALCS - USE EXISTING ELECTRICAL FEED TO POOL EQUIPMENT
5. SINGLE LINE DIAGRAM - SEE BUILDING PERMIT AND APPROVED PLANS
6.NO OVERHEAD UTILITY/SERVICE LINES ARE IN THE VICINITY OF THE NEW POOL OR
SPA
7. ALL OUTLETS SUPPLIED BY SINGLE PHASE, 15A AND 20A, 125V OR 240V BRANCH
CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI
PROTECTION. THIS APPLIES TO OUTLETS REGARDLESS OF THEIR PROXIMITY TO
THE SWIMMING POOL AND IT APPLIES TO CORD-AND-PLUG CONNECTED AND DIRECT
CONNECTED SWIMMING POOL PUMP MOTORS. CEC 680.22 (B)
MECHANICAL/PLUMBING NOTES:
1. ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS
AND IN ACCORDANCE WITH LOCAL REGULATIONS.
2. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED.
3. GAS ISOMETRIC: - NEW 2" PE GAS LINE WITH TRACER WIRE, ±100 LINEAL FEET.
2019 ENERGY EFFICIENCY STANDARDS MANDATORY MEASURES (MF-1R)
1. ANY POOL OR SPA HEATING SYSTEM SHALL BE CERTIFIED TO HAVE: A THERMAL
EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AN
ON-OFF SWITCH MOUNTED OUTSIDE OF THE HEATER; A PERMANENT
WEATHERPROOF PLATE OR CARD WITH OPERATING INSTRUCTIONS; AND SHALL
NOT USE ELECTRIC RESISTANCE HEATING OR A PILOT LIGHT.
2. ANY POOL OR SPA HEATING EQUIPMENT SHALL BE INSTALLED WITH AT LEAST 36"
OF PIPE BETWEEN FILTER AND HEATER, OR DEDICATED SUCTION AND RETURN
LINES, OR BUILT-UP CONNECTIONS FOR FUTURE SOLAR HEATING.
3. OUTDOOR POOLS OR SPAS THAT HAVE A HEAT PUMP OR GAS HEATER SHALL HAVE
A COVER.
4. POOLS SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL
WATER, AND A TIME SWITCH THAT WILL ALLOW ALL PUMPS TO BE SET OR
PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIODS.
5. RESIDENTIAL POOL SYSTEMS OR EQUIPMENT MUST MEET THE PUMP SIZING, FLOW
RATE, PIPING AND FILTERS.
EQUIPMENT NOTES/MANDATORY REQUIREMENTS
1. ANY POOL OR SPA HEATING SYSTEM OR EQUIPMENT MAY BE INSTALLED ONLY IF
THE MANUFACTURER HAS CERTIFIED THAT THE SYSTEM OR EQUIPMENT HAS ALL
OF THE FOLLOWING: EFFICIENCY - A THERMAL EFFICIENCY THAT COMPLIES WITH
THE APPLIANCE EFFICIENCY REGULATIONS; AND ON-OFF SWITCH - A READILY
ACCESSIBLE ON-OFF SWITCH, MOUNTED ON THE OUTSIDE OF THE HEATER THAT
ALLOWS SHUTTING OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT
SETTING; AND INSTRUCTIONS - A PERMANENT, EASILY READABLE , AND
WEATHERPROOF PLATE OR CARD THAT GIVES INSTRUCTION FOR THE ENERGY
EFFICIENT OPERATION OF THE POOL OR SPA HEATER AND FOR THE PROPER CARE
OF POOL OR SPA WATER WHEN A COVER IS USED; AND ELECTRIC RESISTANCE
HEATING - NO ELECTRIC RESISTANCE HEATING; AND
1.1. EXCEPTION 1 TO SECTION 114 (A)4: LISTED PACKAGE UNITS WITH FULLY
INSULATED ENCLOSURE, AND WITH TIGHT-FITTING COVERS THAT ARE
INSULATED TO AT LEAST R-6.
1.2.EXCEPTION 2 TO SECTION 114(A)4: POOLS OR SPAS DERIVING AT LEAST 60
PERCENT OF THE ANNUAL HEATING ENERGY FROM SITE SOLAR ENERGY OR
RECOVERED ENERGY.
2. ANY POOL OR SPA SYSTEM OR EQUIPMENT SHALL BE INSTALLED WITH ALL OF THE
FOLLOWING:
PIPING - SEE MANDATORY MEASURES NOTE #2
COVERS - SEE MANDATORY MEASURES NOTE #3
DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS - SEE MANDATORY
MEASURES NOTE #4
3. ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03 FORM TO BE
COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE
BUILDING INSPECTOR PRIOR TO FINAL INSPECTION APPROVAL,
4. DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS. IF THE SYSTEM OR
EQUIPMENT IS FOR A POOL:
4.1. THE POOL SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL
WATER; AND
4.2.A TIME SWITCH OR SIMILAR CONTROL MECHANISM SHALL BE INSTALLED AS
PART OF THE POOL WATER CIRCULATION CONTROL SYSTEM THAT WILL ALLOW
ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK
ELECTRIC DEMAND PERIOD, AND FOR THE MINIMUM TIME NECESSARY TO
MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC
HEALTH STANDARDS.
5. ALL PUMPS AND PUMP MOTORS INSTALLED SHALL BE LISTED IN THE
COMMISSIONS'S DIRECTORY OF CERTIFIED EQUIPMENT AND SHALL COMPLY WITH
THE APPLIANCE EFFICIENCY REGULATIONS.
6. FILTRATION PUMPS SHALL BE SIZED, OR IF PROGRAMMABLE, SHALL BE
PROGRAMMED, SO THAT THE FILTRATION FLOW RATE IS NOT GREATER THAN THE
RATE NEEDED TO TURN OVER THE POOL WATER VOLUME IN 6 HOURS OR 36 GPM,
WHICHEVER IS GREATER.
7. PUMP MOTORS USED FOR FILTRATION WITH A CAPACITY OF 1 HP OR MORE SHALL
BE MULTI SPEED.
8. EACH AUXILIARY POOL LOAD SHALL BE SERVED BY EITHER SEPARATE PUMPS OR
THE SYSTEM SHALL BE SERVED BY A MULTI SPEED PUMP. EXCEPTION - PUMPS
LESS THAN 1 HP MAY BE SINGLE SPEED.
9. MULTI SPEED PUMPS SHALL HAVE CONTROLS WHICH DEFAULT TO THE FILTRATION
FLOW RATE WHEN NO AUXILIARY POOL LOADS ARE OPERATING.
10. FOR MULTI SPEED PUMPS, THE CONTROLS SHALL DEFAULT TO THE FILTRATION
FLOW SETTING WITHIN 24 HOURS AND SHALL HAVE AN OVERRIDE CAPABILITY FOR
SERVICING.
11. A LENGTH OF STRAIGHT PIPE THAT IS GREATER THAN OR EQUAL TO AT LEAST 4
PIPE DIAMETERS SHALL BE INSTALLED BEFORE THE PUMP.
12. POOL PIPING SHALL BE SIZED SO THAT THE VELOCITY OF THE WATER AT MAXIMUM
FLOW FOR AUXILIARY POOL LOADS DOES NOT EXCEED 8 FEET PER SECOND IN THE
RETURN LINE AND 6 FEET PER SECOND IN THE SUCTION LINE.
13. ALL ELBOWS SHALL BE SWEEP ELBOWS OR ELBOW-TYPE THAT HAVE A PRESSURE
DROP OF LESS THAN THE PRESSURE DROP OF STRAIGHT PIPE WITH A LENGTH OF
30 PIPE DIAMETERS.
14. FILTERS SHALL BE AT LEAST THE SIZE SPECIFIED IN NSF/ANSI 50 FOR PUBLIC POOL
INTENDED.
15. MINIMUM DIAMETER OF BACKWASH VALVES SHALL BE 2 INCHES OF THE DIAMETER
OF THE RETURN PIPE, WHICHEVER IS GREATER.
SAFETY STANDARDS
SECTION AV100.3 OF THE 2016 C.R.C. ADDRESSES THE POOL SAFETY STANDARDS FOR
POOLS, SPAS AND HOT TUBS INSTALLED FOR SINGLE FAMILY RESIDENCE.
FOR THE PURPOSE OF THIS CODE THE FOLLOWING DEFINITIONS ARE APPLICABLE:
SWIMMING POOL: ANY STRUCTURE INTENDED FOR SWIMMING OR RECREATIONAL
BATHING THAT CONTAINS WATER OVER 18 INCHES DEEP.
ENCLOSURE: A FENCE, WALL, OR OTHER BARRIER THAT ISOLATES A SWIMMING
POOL FROM ACCESS TO THE HOME
ENCLOSURE REQUIREMENTS:
AN OUTDOOR SWIMMING POOL, INCLUDING HOT TUBS OR SPAS SHALL BE SURROUNDED
BY A BARRIER WHICH SHALL COMPLY WITH THE FOLLOWING:
1. TOP OF THE BARRIER SHALL BE AT LEAST 60 INCHES ABOVE GRADE MEASURED ON
THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL
1.1. OPENINGS IN TECH BARRIER SHALL NOT ALLOW THE PASSAGE OF A 4 INCH DIA.
SPHERE.
1.2. OPENING BETWEEN THE FINISH GRADE AND THE BOTTOM OF THE BARRIER
SHALL BE MAX. 2 INCHES.
1.3. BARRIERS SHALL BE INSTALLED SO AS NOT HAVE ANY FEATURES WHICH AID IN
CLIMBING.
2. ACCESS GATES SHALL BE A MINIMUM OF 60 INCHES ABOVE GRADE AND SHALL BE
SELF CLOSING AND HAVE SELF LATCHING DEVICE. GATES MUST OPEN OUTWARD
FROM THE POOL. GATES SHALL MEET THE SAME PROVISIONS AS LISTED AS
BARRIERS.
3. OUTSIDE SURFACES SHALL BE FREE OF ANYTHING THAT CAN MAKE THE BARRIER
CLIMBABLE
4. IF USING THE WALL OF THE HOUSE AS AN ENCLOSURE, EXIT ALARMS MUST BE
PLACE ON ALL DOORS THAT PROVIDE DIRECT ACCESS TO THE POOL.
SUCTION OUTLETS:
1. POOLS AND SPAS MUST HAVE AT LEAST TWO CIRCULATION OUTLETS, WHICH ARE
HYDRAULICALLY BALANCED AND SEPARATED BY THREE FEET OR
2. UTILIZATION OF SKIMMERS, PERIMETER OVERFLOW SYSTEMS, OR OTHER
PRE-APPROVED DEVICES IN LIEU OF TRADITIONAL SUCTION DEVICES.
3. THE USE OF OTHER OUTLET DEVICES WHICH MAY MEET ANSI/APSP-7 STANDARDS
BUT DO NOT HAVE A MINIMUM OF THREE FEET BETWEEN OUTLETS IS PROHIBITED.
WORK HOURS
ANY AND ALL WORK WITHIN THE COMMUNITY WILL TAKE PLACE ONLY DURING THE
FOLLOWING HOURS:
SEASON DAYS OF WEEK TIME
OCT 1ST-APR 30 MONDAY -FRIDAY 7:00 AM-5:30 PM
SATURDAY 8:00 AM-5:00 PM
MAY 1ST-SEP 30 MONDAY -FRIDAY 6:00 AM-7:00 PM
SATURDAY 8:00 AM-5:00 PM
ALL SEASONS SUNDAY AND HOLIDAYS NONE
ALL CONSTRUCTION PERSONNEL SHALL VACATE THE COMMUNITY WITHIN THIRTY (30)
MINUTES OF THE END OF THE PERMITTED WORK HOURS. GUARDS AT THE GATE WILL
PERMIT ENTRY DURING THESE HOURS ONLY. IT IS THE RESPONSIBILITY OF THE OWNER
TO NOTIFY THE GATE OF THE DATE, TIMES AND NAMES OF CONSTRUCTION PERSONNEL
AND OTHER VENDORS WHO MAY REQUIRE ENTRY.
MD
U
R
SK
AF
D
FR
VP
SHEET:
DATE:
SCALE:
DWN BY: CE
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 820132SP-1.0COVER SHEETN.T.S.
8/5/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253CBP
BPOL2022-0350 - 81370 PEARY PLACE
ASHER / POOL, SPAS (2) AND GAS OUTLET AT REAR YARD
POOL, SPA AND GAS OUTLET (1) AT REAR YARD, WITH SPA AT SIDE
YARD [POOL ENGINEERING]. APPROVED SITE PLAN AND
ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT
DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND
BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER
INSPECTION. 2019 CALIFORNIA BUILDING CODES.
Safety Features – New pools and spas shall be equipped with
at least two of the following drowning prevention safety features.
(H&S § 115922 – SB No. 442)
• Enclosure that isolates the pool or spa from dwelling.
• Removable Mesh fencing, a gate that is self-latching and
closing and can accommodate a key lockable device.
• Safety pool cover.
• Exit alarms on doors that provide direct access to pool or spa.
• A self-closing self latching device placed on doors providing
direct access to pool or spa.
• An alarm that when placed in a pool or spa, will sound upon
detection. (Surface Motion, Pressure, Sonar, Laser)
09/02/2022
POOL
10'-6"
10'-51
2"
10'-5"24'-6"29'-8"SPA 2
EQUIP.
SPA 2
RESIDENCE
PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINE
PROPERTY LINE
PROPERTY LINE
SELF CLOSING
SELF LATCHING GATE
SELF CLOSING
SELF LATCHING GATE
ALL DOORS TO POOL ALARM 85 dBAE
GAS METER
SPA
TANNING
SHELF
12'
30X36 CLR
30X36 CLR
GAS
GAS
GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS
33'-3"
(2) 2'' P.E. GAS LINES W/ TRACER WIRE
225 L.F. EACH AT 400,000 BTU
10'-9"7'-10"9'-8"12'-014"7'-6"POOL EQUIPMENT
SCOPE OF WORK
SP-2.0SITE PLANASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/16/2022SITE PLAN
SCALE: 3/32"=1'-0"
100
649
POOL/SPA SHALL NOT
BE LOCATED WITHIN
10’-0” FROM ANY SLOPE
1. LAYOUT AND EXCAVATE FOR NEW POOL/SPA & MASTER SPA
2. HAUL AWAY ALL DIRT AS NECESSAARY
3. CONSTRUCT NEW POOL/SPA & MASTER SPA
4. INSTALL NEW EQUIPMENT FOR ALL BODIES OF WATER
CBP
09/02/2022
39'-3"26'1'11'-6"11'-6"
29'10'-2"1'-2"1'-2"1'-2"1'-2"11'-9"18'-9"18'-9"65'-3"19'5'5'
W.D. -7''
W.D. -21''
W.D. -54''
W.D. -54''
W.D. -54''
W.D. -52''
A2
SP-3.1
A1
SP-3.1
A3
SP-3.1
A3
SP-3.1
A1
SP-3.1
A1
SP-3.1
A1
SP-3.1
A4
SP-3.1
A4
SP-3.1
W.D.
-7''
W.D.
-14''
5'15'1'23'-3"W.
D
.
-
3
2
'
'
W.D. -14''
W.D. -21''
W.D. -35''
W.D. -42''
W.D. -49'
W.D. -43''
W.D. -28''1'-2"2'-6"1'1'-6"1'1'-6"MD
MD
MD
MD
MD
MD
3'' PVC TO P-04
3'' PVC TO P-03
3'' PVC TO P-02
3'' PVC TO P-01
H
H
R
R
R1
R1
R3
2-1/2'' PVC FROM P-04
2-1/2'' PVC FROM H-02
2-1/2'' PVC FROM P-06
3'' PVC TO P-06
3'' PVC TO P-05
R1
2-1/2'' PVC FROM H-01
1'' CONDUIT TO JBOX
TYP ALL LIGHTS
MD
MD
3'' PVC TO P-05
MD
MD
R2
R2
R2
2-1/2'' PVC FROM P-02
R3
R3
2-1/2'' PVC FROM P-03
R4
R4
R4
3'' PVC TO P-07
M L
L M L LMHH2-1/2'' PVC FROM P-07
27' x 63'
3'-6' TO 5'
181 I.F.
1058 S.F.
33,660 GAL.
POOL
SIZE
DEPTH
PERIMETER
AREA
VOLUME
SIZE
DEPTH
PERIMETER
AREA
VOLUME
SPA
10'-6'' x 14'
3'-6"
49 I.F.
147 S.F.
3,958 GAL.
WATER SPEC'S
30X36 CLR
5' SET BACK
1'-3"
6"
1'-3"
6"
1'-3"
6"
1'-3"
6"
1'-3"
6"
1'-3"
1'2'
6"
2'1'-6"
METAL STAND
FOR HEATERS
6"
1'-3"
4''
5' SET BACK
METAL STAND
FOR HEATERS
POOL & SPA EQUIPMENT SCHEDULE
NO.TYPE LOCATION MFR MODEL NO.
P-01 FILTER PUMP POOL JANDY VSSHP270DV2A
POOL & SPA LIGHT SCHEDULE
NO.TYPE LOCATION MFR MODEL NO.
10 NICHLESS LED POOL JANDI
2 SPANICHLESS LED
JLU4C24Wxxx
JANDI JLU4C12Wxxx
P-02 INFINITY PUMP POOL JANDY VSSHP270DV2A
P-03 INFINITY PUMP POOL JANDY VSSHP270DV2A
P-04 POOL JANDY VSSHP270DV2A
P-05
JET PUMP
SPA JANDY VSSHP270DV2A
F-01 POOL JANDY CV460FILTER
F-02 SPA JANDY CV460FILTER
H-01 HEATER POOL JANDY JXI400N
H-02 SPA POOL JANDY JXI400N
ELECTRICAL LOAD DEMAND
QTY MODEL PHASE VOLTAGE WATT
8 PUMP JANDY
VSSHP270DV2A SINGLE
AMPS
GAS LOAD DEMAND
QTY MODEL BTU
230 2,190
2 SINGLE 240 600HEATER
JANDY JXI400N
2 HEATER
JANDY JXI400N 399,000
10.5
2.5
TOTAL 89
P-07 JET PUMP SPA JANDY VSSHP270DV2A
P-06 SPA JANDY VSSHP270DV2A
INFINITY PUMP
FILTER PUMP
SP-3.0ENLARGED POOL PLANSHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/24/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253A
SCALE: 1/4''=1'-0"
ENLARGED POOL PLAN B
SCALE: 1/4''=1'-0"
PLUMBING PLAN
1
SCALE: 1/4''=1'-0"
EQUIPMENT LAYOUT BASE
2
SCALE: 1/4''=1'-0"
EQUIPMENT LAYOUT STAND
CBP
09/02/2022
NATURAL GRADE
WATER LINE
6"
6"
STONE / TILE CAP
4'' CONCRETE S.O.G.
1'-0"
6"2'-0"10"
PEBBLE SHEEN
FINISH T.B.D.
STONE / TILE TO
TROUGH FLOOR
1'' FIBERGLASS GRATE
GUNITE WALL PER
STRUCTURAL ENGINEERING
F. F.
GUNITE SHELL PER
STRUCTURAL ENGINEERING
WATER LINE
6"
1"
8"
1'-2"
6"
APPLY 2 COATS
WATERPROOFING TO
OVER FLOW TROUGH
4'' CONCRETE S.O.G.
WATERPROOF NON-POROUS
SLIPSHEET
TILE & SETTING BED
STONE / TILE MITER ALL CORNERS
10"
1'-2"1'-2"1'-2"
7"
8"
8"
8"
8"
6"
3'-11"
PER PLAN
8"
1'-2"
PEBBLE SHEEN FINISH T.B.D.
WATER LINE FINISH FLOOR
5"
8"
6"PEBBLE SHEEN FINISH T.B.D.
1'-9"
STEPS BEYOND
WATER LINEFINISH FLOOR
10"
STEPS BEYOND
STEPS BEYOND
STEPS BEYOND
STEPS BEYOND
A1
SP-3.1
A1
SP-3.1
STEPS BEYOND
1'-10"
10"
STEP BEYOND
BENCH BEYOND
11"
WATER LINEFINISH FLOOR
6"8"10"
5"
8"
6"
STONE / TILE COPING
MITER ALL CORNERS
4'' CONCRETE S.O.G
WATERPROOF NON-POROUS
SLIPSHEET
TILE & SETTING BED
APPLY 2 COATS WATERPROOFING
TO OVER FLOW TROUGH
6'' WATER LINE TILE
PEBBLE SHEEN FINISH T.B.D.
SP-3.1SECTIONS & DETAILSSHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/24/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253A1
SCALE: 1''=1'-0"
POOL EDGE DETAIL
A3
SCALE: 1''=1'-0"
INFINITY WALL DETAIL
A2
SCALE: 1''=1'-0"
POOL STEPS DETAIL
A4
SCALE: 1''=1'-0"
SPA SECTION
CBP
09/02/2022
AF
W.D. -21''
W.D. -42''
5'1'-6"1'-6"5'1'-6"A2
SP-3.2
A2
SP-3.2
1'-6"1'-1"1'-1"1'-1"1'-1"R
R
L
HML M
AF LMH
2" PVC FROM H-01
2-1/2" PVC FROM P-022-1/2" PVC TO P-02 2-1/2" PVC TO P-01
WATER LINE
1'-9"
1'-9"
1'-6"6'' WATER LINE STONE
PEBBLE SHEEN FINISH T.B.D.
11"
3-1/2'' CONCRETE BASE
3/8'' PORCELAIN TILE WITH
5/8'' THINSET SETTING BED
3/4'' STONE WITH
5/8'' THINSET SETTING BED
GUNITE SHELL PER
STRUCTURAL ENGINEERING
30X36 CLR 2'-6"2'-6"1'-3"6"1'-3"6"2'1'2'-6"6"
MASTER SPA EQUIPMENT SCHEDULE
NO.TYPE LOCATION MFR MODEL NO.
P-01 FILTER PUMP POOL JANDY VSSHP270DV2A
MASTER SPA LIGHT SCHEDULE
NO.TYPE LOCATION MFR MODEL NO.
1 NICHLESS LED POOL JANDI JLU4C12Wxxx
P-02 POOL JANDY VSSHP270DV2A
F-01 POOL JANDY
H-01 POOL JANDY
JET PUMP
FILTER
HEATER
CV460
JXI400N
ELECTRICAL LOAD DEMAND
QTY MODEL PHASE VOLTAGE WATT
2 PUMP JANDY
VSSHP270DV2A SINGLE
AMPS
230 2,190
1 SINGLE 240 600HEATER
JANDY JXI400N
10.5
2.5
TOTAL 23.5 SP-3.2MASTER SPA PLANS& EQUIPMENT LAYOUTSHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/24/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253A
SCALE: 1/2''=1'-0"
ENLARGED MASTER SPA A1
SCALE: 1/2''=1'-0"
MASTER SPA PLUMBING
A2
SCALE: 3/4''=1'-0"
MASTER SPA SECTION
A4
SCALE: 1/2''=1'-0"
MASTER SPA EQUIPMENT
CBP
09/02/2022
S1ENGINEERINGASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 9225309/02/2022
S1ENGINEERINGASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 9225309/02/2022