Loading...
BPOL2022-0350ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT F P D SERVICES INC DBA STOKER POOLS 43653 Parkway Esplanade East La Quinta CA 92253 (310)980-3399 ACCOUNTING@STOKE RPOOLS.COM CONTRACTOR F P D SERVICES INC DBA STOKER POOLS 43653 Parkway Esplanade East La Quinta CA 92253 (310)980-3399 ACCOUNTING@STOKE RPOOLS.COM OWNER Barbara Is Ready, LLC La Quinta CA 92253 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL DUANE CLAYTON 9/2/2022 9/2/2022 - NOTIFIED APPLICANT THAT PLAN REVIEW IS COMPLETE AND APPROVED. CONDITIONS Description: ASHER / POOL, SPAS (2) AND GAS OUTLET AT REAR YARD Type: POOL CONSTRUCTION (WEB) Subtype: PRIVATE Status: FINALED Applied: 8/24/2022 ECON Parcel No: 767680028 Site Address: 81370 PEARY PL LA QUINTA,CA 92253 Approved: 9/2/2022 DCL Subdivision: TR 33076-1 Block: Lot: 66 Issued: 9/2/2022 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/4/2023 DCL Valuation: $250,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: POOL, SPA AND GAS OUTLET (1) AT REAR YARD, WITH SPA AT SIDE YARD [POOL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION Printed: Thursday, October 19, 2023 2:55:19 PM 1 of 6 Permit Details City of La Quinta PERMIT NUMBER BPOL2022-0350 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $10.00 $10.00 9/2/22 WEB12954 717807967 CREDIT 820132 ECON Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $10.00 $10.00 DEVICES, FIRST 20 101-0000-42403 0 $27.79 $27.79 9/2/22 WEB12954 717807967 CREDIT 820132 ECON DEVICES, FIRST 20 PC 101-0000-42600 0 $27.79 $27.79 9/2/22 WEB12954 717807967 CREDIT 820132 ECON Total Paid for ELECTRICAL 2021: $55.58 $55.58 DETACHED SPA/WATER FEATURE/OTHER 101-0000-42404 0 $208.41 $208.41 9/2/22 WEB12954 717807967 CREDIT 820132 ECON SWIMMING POOL/SPA/WATER FEATURE 101-0000-42404 0 $208.41 $208.41 9/2/22 WEB12954 717807967 CREDIT 820132 ECON SWIMMING POOL/SPA/WATER FEATURE PC 101-0000-42600 0 $113.38 $113.38 9/2/22 WEB12954 717807967 CREDIT 820132 ECON Total Paid for POOL / SPA 2021: $530.20 $530.20 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 9/2/22 WEB12954 717807967 CREDIT 820132 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 9/2/22 WEB12954 717807967 CREDIT 820132 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$611.78 $611.78 Printed: Thursday, October 19, 2023 2:55:19 PM 2 of 6 Permit Details City of La Quinta PERMIT NUMBER BPOL2022-0350 PRE-GUNITE DCL 9/15/2022 9/15/2022 PARTIALLY APPROVED eTRAKiT Inspection Request 9/14/2022 11:09 AM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - EXCLUDES SIDE YARD SPA. UNDERGROUND PLBG JAN 9/19/2022 9/19/2022 PARTIALLY APPROVED eTRAKiT Inspection Request 9/16/2022 9:43 AM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM -SPA AT WEST SIDE YARD ONLY UNDERGROUND GAS JAN 9/19/2022 9/19/2022 APPROVED eTRAKiT Inspection Request 9/16/2022 9:43 AM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM Printed: Thursday, October 19, 2023 2:55:19 PM 3 of 6 Permit Details City of La Quinta PERMIT NUMBER BPOL2022-0350 UNDERGROUND ELEC JAN 9/19/2022 9/19/2022 PARTIALLY APPROVED eTRAKiT Inspection Request 9/16/2022 9:43 AM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM -SPA AT WEST SIDE YARD ONLY PRE-GUNITE JAN 9/19/2022 9/19/2022 PARTIALLY APPROVED eTRAKiT Inspection Request 9/16/2022 9:43 AM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM Spa at west side yard only DECK BOND BLAK 1/12/2023 1/12/2023 PARTIALLY APPROVED eTRAKiT Inspection Request 1/11/2023 10:17 AM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM OK to proceed with pour of concrete at the spa area. Verified for bonding points number eight and tied to the rebar. Only spa. Printed: Thursday, October 19, 2023 2:55:19 PM 4 of 6 Permit Details City of La Quinta PERMIT NUMBER BPOL2022-0350 DECK BOND BLAK 1/18/2023 1/18/2023 PARTIALLY APPROVED eTRAKiT Inspection Request 1/17/2023 3:13 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM Verified five points of bonding at back pool. OK to proceed with flat work. Verified five points of bonding around pool OK to proceed with flat work. PRE-PLASTER BLAK 2/21/2023 2/21/2023 APPROVED eTRAKiT Inspection Request 2/17/2023 12:30 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM FINAL**DCL 5/2/2023 5/2/2023 DISAPPROVE D eTRAKiT Inspection Request 5/1/2023 2:09 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - NUMBER SIX BLACK WIRE NOT PERMITTED TO BE REIDENTIFIED (TAPED GREEN) AS NON-CURRENT CARRYING (GREEN/GROUND). SEE SPA AND POOL SUB PANELS. Printed: Thursday, October 19, 2023 2:55:19 PM 5 of 6 Permit Details City of La Quinta PERMIT NUMBER BPOL2022-0350 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/2/2022 DUANE CLAYTON PLAN SET (APPROVED)BPOL2022-0350 - PLAN SET (APPROVED) CF.pdf 1 DOC 8/24/2022 Etrakit Contractor 1ST SUBMITTAL - PLAN SET Lot 66_POOL_SPA_0824.pdf 1 BOND INFORMATION FINAL**DCL 5/4/2023 5/4/2023 APPROVED eTRAKiT Inspection Request 5/3/2023 1:45 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81370 PEARY PL Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG NS - ETRAKIT (1 DAY) DUANE CLAYTON 8/24/2022 8/25/2022 9/2/2022 APPROVED - SEE APPROVED PLAN SET IN ATTACHMENTS. PARENT PROJECTS Printed: Thursday, October 19, 2023 2:55:19 PM 6 of 6 Permit Details City of La Quinta PERMIT NUMBER BPOL2022-0350 AVENUE 54 BAFFIN AVE.ROSS AVE.F R E M O N T W A Y PIKE PL.PEARLY PL.MONROE STMADISON STAVENUE 52 COLUMBIA WAY AMUN DS O N AVE. SITE MERIWETHER WAYHUMBOLDT BLVDMERIWETHER WAYHUMBOLDT BLVDROSS A V E. ELS W O R T H DE S O T OSHACKLETON SHEET INDEXVICINITY MAP CUSTOM POOL AND SPA FOR ASHER LOT 66 81370 PEARLY PLACE LA QUINTA, CA 92253 GENERAL NOTES TITLE SP-1.0 COVER SHEET SP-2.0 SITE PLAN SP-3.0 ENLARGED POOL/SPA PLAN SP-3.1 SECTIONS & DETAILS SP-3.2 MASTER SPA & EQUIPMENT LAYOUT S1 ENGINEERING DETAIL 100 S2 ENGINEERING DETAIL 649 NO. ABBREVIATIONS REFERENCE SYMBOLS CITY OF LA QUINTA NOTES 100'-0" F.F. ELEV. GRIDLINE ELEVATION MARKER DETAIL CALLOUT SECTION CUTSHEET NO SHEET NO 14 MATERIAL KEYNOTE CONCRETE GRAVEL EARTH WOOD FINISH CONCRETE MASONRY UNIT STONE GUNITE WATER (SURFACE) WATER (SECTION) 1 ELEVATION CALLOUTSHEET NO IFINISH KEYNOTE GRASS F-1 POOL LIGHT POOL DRAIN SPILL MAIN DRAIN SUCTION - 3' MIN. SEPARATION UMBRELLA SLEEVE POOL RETURN SKIMMER AUTO FILL DECK JET AQUASTAR 4" FLOOR RETURN BLACK VACUUM PORT W/ VACUUM LOCK J 01 POOL EQUIPMENT TAG GENERAL NOTES: 1. PROPOSED CONSTRUCTION WILL CONFORM TO THE CURRENT CODES (CBC 106.1.1) 2019 California Residential Code, Title 24 Part 2.5 2019 California Electrical Code, Title 24 Part 3 2019 California Mechanical Code, Title 24 Part 4 2019 California Plumbing Code, Title 24 Part 5 2019 California Energy Code, Title 24 Part 6 2019 California Fire Code, Title 24 Part 9 2. GOVERNMENT CODE SECTION 4216.2. (A) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR TO COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND, IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER SUITABLE MARKINGS THE AREA TO BE EXCAVATED. 3. THE CITY BUILDING INSPECTOR HAS THE AUTHORITY TO REQUEST FULLY REVISED PLAN SHEETS WITH ALL FIELD CHANGES CLOUDED WITH DELTAS TO BE SUBMITTED FOR CITY PLAN REVIEW WHEN HE/SHE DETERMINES THE NUMBER OF FIELD REVISIONS WARRANT SUCH A REQUEST. ELECTRICAL NOTES: 1. THE EQUIPMENT BONDING GRID SHALL EXTEND UNDER PAVED AND UNPAVED SURFACES FOR 3 FEET HORIZONTALLY BEYOND THE INSIDE WALLS OF THE POOL. 2. ALL METAL-SHEATHED CABLES AND RACEWAYS, METAL PIPING, AND ALL FIXED METAL PARTS THAT ARE WITHIN THE FOLLOWING DISTANCES OF THE POOL, EXCEPT THOSE SEPARATED FROM THE POOL BY A PERMANENT BARRIER, SHALL BE BONDED: A.) WITHIN 5 FEET HORIZONTALLY OF THE INSIDE WALLS OF THE POOL. B.) WITHIN 12 FEET MEASURED VERTICALLY ABOVE THE MAXIMUM WATER LEVEL OF THE POOL, OR ANY SLIDES, DIVING BOARDS ETC... 3. PROVIDE 36" WORKING CLEARANCES FOR THE POOL EQUIPMENT DISCONNECT AND SUB PANEL (CEC ART 110.26) 4. LOAD CALCS - USE EXISTING ELECTRICAL FEED TO POOL EQUIPMENT 5. SINGLE LINE DIAGRAM - SEE BUILDING PERMIT AND APPROVED PLANS 6.NO OVERHEAD UTILITY/SERVICE LINES ARE IN THE VICINITY OF THE NEW POOL OR SPA 7. ALL OUTLETS SUPPLIED BY SINGLE PHASE, 15A AND 20A, 125V OR 240V BRANCH CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION. THIS APPLIES TO OUTLETS REGARDLESS OF THEIR PROXIMITY TO THE SWIMMING POOL AND IT APPLIES TO CORD-AND-PLUG CONNECTED AND DIRECT CONNECTED SWIMMING POOL PUMP MOTORS. CEC 680.22 (B) MECHANICAL/PLUMBING NOTES: 1. ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS. 2. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED. 3. GAS ISOMETRIC: - NEW 2" PE GAS LINE WITH TRACER WIRE, ±100 LINEAL FEET. 2019 ENERGY EFFICIENCY STANDARDS MANDATORY MEASURES (MF-1R) 1. ANY POOL OR SPA HEATING SYSTEM SHALL BE CERTIFIED TO HAVE: A THERMAL EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AN ON-OFF SWITCH MOUNTED OUTSIDE OF THE HEATER; A PERMANENT WEATHERPROOF PLATE OR CARD WITH OPERATING INSTRUCTIONS; AND SHALL NOT USE ELECTRIC RESISTANCE HEATING OR A PILOT LIGHT. 2. ANY POOL OR SPA HEATING EQUIPMENT SHALL BE INSTALLED WITH AT LEAST 36" OF PIPE BETWEEN FILTER AND HEATER, OR DEDICATED SUCTION AND RETURN LINES, OR BUILT-UP CONNECTIONS FOR FUTURE SOLAR HEATING. 3. OUTDOOR POOLS OR SPAS THAT HAVE A HEAT PUMP OR GAS HEATER SHALL HAVE A COVER. 4. POOLS SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL WATER, AND A TIME SWITCH THAT WILL ALLOW ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIODS. 5. RESIDENTIAL POOL SYSTEMS OR EQUIPMENT MUST MEET THE PUMP SIZING, FLOW RATE, PIPING AND FILTERS. EQUIPMENT NOTES/MANDATORY REQUIREMENTS 1. ANY POOL OR SPA HEATING SYSTEM OR EQUIPMENT MAY BE INSTALLED ONLY IF THE MANUFACTURER HAS CERTIFIED THAT THE SYSTEM OR EQUIPMENT HAS ALL OF THE FOLLOWING: EFFICIENCY - A THERMAL EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AND ON-OFF SWITCH - A READILY ACCESSIBLE ON-OFF SWITCH, MOUNTED ON THE OUTSIDE OF THE HEATER THAT ALLOWS SHUTTING OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING; AND INSTRUCTIONS - A PERMANENT, EASILY READABLE , AND WEATHERPROOF PLATE OR CARD THAT GIVES INSTRUCTION FOR THE ENERGY EFFICIENT OPERATION OF THE POOL OR SPA HEATER AND FOR THE PROPER CARE OF POOL OR SPA WATER WHEN A COVER IS USED; AND ELECTRIC RESISTANCE HEATING - NO ELECTRIC RESISTANCE HEATING; AND 1.1. EXCEPTION 1 TO SECTION 114 (A)4: LISTED PACKAGE UNITS WITH FULLY INSULATED ENCLOSURE, AND WITH TIGHT-FITTING COVERS THAT ARE INSULATED TO AT LEAST R-6. 1.2.EXCEPTION 2 TO SECTION 114(A)4: POOLS OR SPAS DERIVING AT LEAST 60 PERCENT OF THE ANNUAL HEATING ENERGY FROM SITE SOLAR ENERGY OR RECOVERED ENERGY. 2. ANY POOL OR SPA SYSTEM OR EQUIPMENT SHALL BE INSTALLED WITH ALL OF THE FOLLOWING: PIPING - SEE MANDATORY MEASURES NOTE #2 COVERS - SEE MANDATORY MEASURES NOTE #3 DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS - SEE MANDATORY MEASURES NOTE #4 3. ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03 FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO FINAL INSPECTION APPROVAL, 4. DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS. IF THE SYSTEM OR EQUIPMENT IS FOR A POOL: 4.1. THE POOL SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL WATER; AND 4.2.A TIME SWITCH OR SIMILAR CONTROL MECHANISM SHALL BE INSTALLED AS PART OF THE POOL WATER CIRCULATION CONTROL SYSTEM THAT WILL ALLOW ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIOD, AND FOR THE MINIMUM TIME NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC HEALTH STANDARDS. 5. ALL PUMPS AND PUMP MOTORS INSTALLED SHALL BE LISTED IN THE COMMISSIONS'S DIRECTORY OF CERTIFIED EQUIPMENT AND SHALL COMPLY WITH THE APPLIANCE EFFICIENCY REGULATIONS. 6. FILTRATION PUMPS SHALL BE SIZED, OR IF PROGRAMMABLE, SHALL BE PROGRAMMED, SO THAT THE FILTRATION FLOW RATE IS NOT GREATER THAN THE RATE NEEDED TO TURN OVER THE POOL WATER VOLUME IN 6 HOURS OR 36 GPM, WHICHEVER IS GREATER. 7. PUMP MOTORS USED FOR FILTRATION WITH A CAPACITY OF 1 HP OR MORE SHALL BE MULTI SPEED. 8. EACH AUXILIARY POOL LOAD SHALL BE SERVED BY EITHER SEPARATE PUMPS OR THE SYSTEM SHALL BE SERVED BY A MULTI SPEED PUMP. EXCEPTION - PUMPS LESS THAN 1 HP MAY BE SINGLE SPEED. 9. MULTI SPEED PUMPS SHALL HAVE CONTROLS WHICH DEFAULT TO THE FILTRATION FLOW RATE WHEN NO AUXILIARY POOL LOADS ARE OPERATING. 10. FOR MULTI SPEED PUMPS, THE CONTROLS SHALL DEFAULT TO THE FILTRATION FLOW SETTING WITHIN 24 HOURS AND SHALL HAVE AN OVERRIDE CAPABILITY FOR SERVICING. 11. A LENGTH OF STRAIGHT PIPE THAT IS GREATER THAN OR EQUAL TO AT LEAST 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE THE PUMP. 12. POOL PIPING SHALL BE SIZED SO THAT THE VELOCITY OF THE WATER AT MAXIMUM FLOW FOR AUXILIARY POOL LOADS DOES NOT EXCEED 8 FEET PER SECOND IN THE RETURN LINE AND 6 FEET PER SECOND IN THE SUCTION LINE. 13. ALL ELBOWS SHALL BE SWEEP ELBOWS OR ELBOW-TYPE THAT HAVE A PRESSURE DROP OF LESS THAN THE PRESSURE DROP OF STRAIGHT PIPE WITH A LENGTH OF 30 PIPE DIAMETERS. 14. FILTERS SHALL BE AT LEAST THE SIZE SPECIFIED IN NSF/ANSI 50 FOR PUBLIC POOL INTENDED. 15. MINIMUM DIAMETER OF BACKWASH VALVES SHALL BE 2 INCHES OF THE DIAMETER OF THE RETURN PIPE, WHICHEVER IS GREATER. SAFETY STANDARDS SECTION AV100.3 OF THE 2016 C.R.C. ADDRESSES THE POOL SAFETY STANDARDS FOR POOLS, SPAS AND HOT TUBS INSTALLED FOR SINGLE FAMILY RESIDENCE. FOR THE PURPOSE OF THIS CODE THE FOLLOWING DEFINITIONS ARE APPLICABLE: SWIMMING POOL: ANY STRUCTURE INTENDED FOR SWIMMING OR RECREATIONAL BATHING THAT CONTAINS WATER OVER 18 INCHES DEEP. ENCLOSURE: A FENCE, WALL, OR OTHER BARRIER THAT ISOLATES A SWIMMING POOL FROM ACCESS TO THE HOME ENCLOSURE REQUIREMENTS: AN OUTDOOR SWIMMING POOL, INCLUDING HOT TUBS OR SPAS SHALL BE SURROUNDED BY A BARRIER WHICH SHALL COMPLY WITH THE FOLLOWING: 1. TOP OF THE BARRIER SHALL BE AT LEAST 60 INCHES ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL 1.1. OPENINGS IN TECH BARRIER SHALL NOT ALLOW THE PASSAGE OF A 4 INCH DIA. SPHERE. 1.2. OPENING BETWEEN THE FINISH GRADE AND THE BOTTOM OF THE BARRIER SHALL BE MAX. 2 INCHES. 1.3. BARRIERS SHALL BE INSTALLED SO AS NOT HAVE ANY FEATURES WHICH AID IN CLIMBING. 2. ACCESS GATES SHALL BE A MINIMUM OF 60 INCHES ABOVE GRADE AND SHALL BE SELF CLOSING AND HAVE SELF LATCHING DEVICE. GATES MUST OPEN OUTWARD FROM THE POOL. GATES SHALL MEET THE SAME PROVISIONS AS LISTED AS BARRIERS. 3. OUTSIDE SURFACES SHALL BE FREE OF ANYTHING THAT CAN MAKE THE BARRIER CLIMBABLE 4. IF USING THE WALL OF THE HOUSE AS AN ENCLOSURE, EXIT ALARMS MUST BE PLACE ON ALL DOORS THAT PROVIDE DIRECT ACCESS TO THE POOL. SUCTION OUTLETS: 1. POOLS AND SPAS MUST HAVE AT LEAST TWO CIRCULATION OUTLETS, WHICH ARE HYDRAULICALLY BALANCED AND SEPARATED BY THREE FEET OR 2. UTILIZATION OF SKIMMERS, PERIMETER OVERFLOW SYSTEMS, OR OTHER PRE-APPROVED DEVICES IN LIEU OF TRADITIONAL SUCTION DEVICES. 3. THE USE OF OTHER OUTLET DEVICES WHICH MAY MEET ANSI/APSP-7 STANDARDS BUT DO NOT HAVE A MINIMUM OF THREE FEET BETWEEN OUTLETS IS PROHIBITED. WORK HOURS ANY AND ALL WORK WITHIN THE COMMUNITY WILL TAKE PLACE ONLY DURING THE FOLLOWING HOURS: SEASON DAYS OF WEEK TIME OCT 1ST-APR 30 MONDAY -FRIDAY 7:00 AM-5:30 PM SATURDAY 8:00 AM-5:00 PM MAY 1ST-SEP 30 MONDAY -FRIDAY 6:00 AM-7:00 PM SATURDAY 8:00 AM-5:00 PM ALL SEASONS SUNDAY AND HOLIDAYS NONE ALL CONSTRUCTION PERSONNEL SHALL VACATE THE COMMUNITY WITHIN THIRTY (30) MINUTES OF THE END OF THE PERMITTED WORK HOURS. GUARDS AT THE GATE WILL PERMIT ENTRY DURING THESE HOURS ONLY. IT IS THE RESPONSIBILITY OF THE OWNER TO NOTIFY THE GATE OF THE DATE, TIMES AND NAMES OF CONSTRUCTION PERSONNEL AND OTHER VENDORS WHO MAY REQUIRE ENTRY. MD U R SK AF D FR VP SHEET: DATE: SCALE: DWN BY: CE dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 820132SP-1.0COVER SHEETN.T.S. 8/5/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253CBP BPOL2022-0350 - 81370 PEARY PLACE ASHER / POOL, SPAS (2) AND GAS OUTLET AT REAR YARD POOL, SPA AND GAS OUTLET (1) AT REAR YARD, WITH SPA AT SIDE YARD [POOL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Safety Features – New pools and spas shall be equipped with at least two of the following drowning prevention safety features. (H&S § 115922 – SB No. 442) • Enclosure that isolates the pool or spa from dwelling. • Removable Mesh fencing, a gate that is self-latching and closing and can accommodate a key lockable device. • Safety pool cover. • Exit alarms on doors that provide direct access to pool or spa. • A self-closing self latching device placed on doors providing direct access to pool or spa. • An alarm that when placed in a pool or spa, will sound upon detection. (Surface Motion, Pressure, Sonar, Laser) 09/02/2022 POOL 10'-6" 10'-51 2" 10'-5"24'-6"29'-8"SPA 2 EQUIP. SPA 2 RESIDENCE PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINE PROPERTY LINE PROPERTY LINE SELF CLOSING SELF LATCHING GATE SELF CLOSING SELF LATCHING GATE ALL DOORS TO POOL ALARM 85 dBAE GAS METER SPA TANNING SHELF 12' 30X36 CLR 30X36 CLR GAS GAS GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS 33'-3" (2) 2'' P.E. GAS LINES W/ TRACER WIRE 225 L.F. EACH AT 400,000 BTU 10'-9"7'-10"9'-8"12'-014"7'-6"POOL EQUIPMENT SCOPE OF WORK SP-2.0SITE PLANASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253SHEET: DATE: SCALE: DWN BY: CRAIG dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/16/2022SITE PLAN SCALE: 3/32"=1'-0" 100 649 POOL/SPA SHALL NOT BE LOCATED WITHIN 10’-0” FROM ANY SLOPE 1. LAYOUT AND EXCAVATE FOR NEW POOL/SPA & MASTER SPA 2. HAUL AWAY ALL DIRT AS NECESSAARY 3. CONSTRUCT NEW POOL/SPA & MASTER SPA 4. INSTALL NEW EQUIPMENT FOR ALL BODIES OF WATER CBP 09/02/2022 39'-3"26'1'11'-6"11'-6" 29'10'-2"1'-2"1'-2"1'-2"1'-2"11'-9"18'-9"18'-9"65'-3"19'5'5' W.D. -7'' W.D. -21'' W.D. -54'' W.D. -54'' W.D. -54'' W.D. -52'' A2 SP-3.1 A1 SP-3.1 A3 SP-3.1 A3 SP-3.1 A1 SP-3.1 A1 SP-3.1 A1 SP-3.1 A4 SP-3.1 A4 SP-3.1 W.D. -7'' W.D. -14'' 5'15'1'23'-3"W. D . - 3 2 ' ' W.D. -14'' W.D. -21'' W.D. -35'' W.D. -42'' W.D. -49' W.D. -43'' W.D. -28''1'-2"2'-6"1'1'-6"1'1'-6"MD MD MD MD MD MD 3'' PVC TO P-04 3'' PVC TO P-03 3'' PVC TO P-02 3'' PVC TO P-01 H H R R R1 R1 R3 2-1/2'' PVC FROM P-04 2-1/2'' PVC FROM H-02 2-1/2'' PVC FROM P-06 3'' PVC TO P-06 3'' PVC TO P-05 R1 2-1/2'' PVC FROM H-01 1'' CONDUIT TO JBOX TYP ALL LIGHTS MD MD 3'' PVC TO P-05 MD MD R2 R2 R2 2-1/2'' PVC FROM P-02 R3 R3 2-1/2'' PVC FROM P-03 R4 R4 R4 3'' PVC TO P-07 M L L M L LMHH2-1/2'' PVC FROM P-07 27' x 63' 3'-6' TO 5' 181 I.F. 1058 S.F. 33,660 GAL. POOL SIZE DEPTH PERIMETER AREA VOLUME SIZE DEPTH PERIMETER AREA VOLUME SPA 10'-6'' x 14' 3'-6" 49 I.F. 147 S.F. 3,958 GAL. WATER SPEC'S 30X36 CLR 5' SET BACK 1'-3" 6" 1'-3" 6" 1'-3" 6" 1'-3" 6" 1'-3" 6" 1'-3" 1'2' 6" 2'1'-6" METAL STAND FOR HEATERS 6" 1'-3" 4'' 5' SET BACK METAL STAND FOR HEATERS POOL & SPA EQUIPMENT SCHEDULE NO.TYPE LOCATION MFR MODEL NO. P-01 FILTER PUMP POOL JANDY VSSHP270DV2A POOL & SPA LIGHT SCHEDULE NO.TYPE LOCATION MFR MODEL NO. 10 NICHLESS LED POOL JANDI 2 SPANICHLESS LED JLU4C24Wxxx JANDI JLU4C12Wxxx P-02 INFINITY PUMP POOL JANDY VSSHP270DV2A P-03 INFINITY PUMP POOL JANDY VSSHP270DV2A P-04 POOL JANDY VSSHP270DV2A P-05 JET PUMP SPA JANDY VSSHP270DV2A F-01 POOL JANDY CV460FILTER F-02 SPA JANDY CV460FILTER H-01 HEATER POOL JANDY JXI400N H-02 SPA POOL JANDY JXI400N ELECTRICAL LOAD DEMAND QTY MODEL PHASE VOLTAGE WATT 8 PUMP JANDY VSSHP270DV2A SINGLE AMPS GAS LOAD DEMAND QTY MODEL BTU 230 2,190 2 SINGLE 240 600HEATER JANDY JXI400N 2 HEATER JANDY JXI400N 399,000 10.5 2.5 TOTAL 89 P-07 JET PUMP SPA JANDY VSSHP270DV2A P-06 SPA JANDY VSSHP270DV2A INFINITY PUMP FILTER PUMP SP-3.0ENLARGED POOL PLANSHEET: DATE: SCALE: DWN BY: CRAIG dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/24/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253A SCALE: 1/4''=1'-0" ENLARGED POOL PLAN B SCALE: 1/4''=1'-0" PLUMBING PLAN 1 SCALE: 1/4''=1'-0" EQUIPMENT LAYOUT BASE 2 SCALE: 1/4''=1'-0" EQUIPMENT LAYOUT STAND CBP 09/02/2022 NATURAL GRADE WATER LINE 6" 6" STONE / TILE CAP 4'' CONCRETE S.O.G. 1'-0" 6"2'-0"10" PEBBLE SHEEN FINISH T.B.D. STONE / TILE TO TROUGH FLOOR 1'' FIBERGLASS GRATE GUNITE WALL PER STRUCTURAL ENGINEERING F. F. GUNITE SHELL PER STRUCTURAL ENGINEERING WATER LINE 6" 1" 8" 1'-2" 6" APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH 4'' CONCRETE S.O.G. WATERPROOF NON-POROUS SLIPSHEET TILE & SETTING BED STONE / TILE MITER ALL CORNERS 10" 1'-2"1'-2"1'-2" 7" 8" 8" 8" 8" 6" 3'-11" PER PLAN 8" 1'-2" PEBBLE SHEEN FINISH T.B.D. WATER LINE FINISH FLOOR 5" 8" 6"PEBBLE SHEEN FINISH T.B.D. 1'-9" STEPS BEYOND WATER LINEFINISH FLOOR 10" STEPS BEYOND STEPS BEYOND STEPS BEYOND STEPS BEYOND A1 SP-3.1 A1 SP-3.1 STEPS BEYOND 1'-10" 10" STEP BEYOND BENCH BEYOND 11" WATER LINEFINISH FLOOR 6"8"10" 5" 8" 6" STONE / TILE COPING MITER ALL CORNERS 4'' CONCRETE S.O.G WATERPROOF NON-POROUS SLIPSHEET TILE & SETTING BED APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH 6'' WATER LINE TILE PEBBLE SHEEN FINISH T.B.D. SP-3.1SECTIONS & DETAILSSHEET: DATE: SCALE: DWN BY: CRAIG dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/24/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253A1 SCALE: 1''=1'-0" POOL EDGE DETAIL A3 SCALE: 1''=1'-0" INFINITY WALL DETAIL A2 SCALE: 1''=1'-0" POOL STEPS DETAIL A4 SCALE: 1''=1'-0" SPA SECTION CBP 09/02/2022 AF W.D. -21'' W.D. -42'' 5'1'-6"1'-6"5'1'-6"A2 SP-3.2 A2 SP-3.2 1'-6"1'-1"1'-1"1'-1"1'-1"R R L HML M AF LMH 2" PVC FROM H-01 2-1/2" PVC FROM P-022-1/2" PVC TO P-02 2-1/2" PVC TO P-01 WATER LINE 1'-9" 1'-9" 1'-6"6'' WATER LINE STONE PEBBLE SHEEN FINISH T.B.D. 11" 3-1/2'' CONCRETE BASE 3/8'' PORCELAIN TILE WITH 5/8'' THINSET SETTING BED 3/4'' STONE WITH 5/8'' THINSET SETTING BED GUNITE SHELL PER STRUCTURAL ENGINEERING 30X36 CLR 2'-6"2'-6"1'-3"6"1'-3"6"2'1'2'-6"6" MASTER SPA EQUIPMENT SCHEDULE NO.TYPE LOCATION MFR MODEL NO. P-01 FILTER PUMP POOL JANDY VSSHP270DV2A MASTER SPA LIGHT SCHEDULE NO.TYPE LOCATION MFR MODEL NO. 1 NICHLESS LED POOL JANDI JLU4C12Wxxx P-02 POOL JANDY VSSHP270DV2A F-01 POOL JANDY H-01 POOL JANDY JET PUMP FILTER HEATER CV460 JXI400N ELECTRICAL LOAD DEMAND QTY MODEL PHASE VOLTAGE WATT 2 PUMP JANDY VSSHP270DV2A SINGLE AMPS 230 2,190 1 SINGLE 240 600HEATER JANDY JXI400N 10.5 2.5 TOTAL 23.5 SP-3.2MASTER SPA PLANS& EQUIPMENT LAYOUTSHEET: DATE: SCALE: DWN BY: CRAIG dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201328/24/2022ASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 92253A SCALE: 1/2''=1'-0" ENLARGED MASTER SPA A1 SCALE: 1/2''=1'-0" MASTER SPA PLUMBING A2 SCALE: 3/4''=1'-0" MASTER SPA SECTION A4 SCALE: 1/2''=1'-0" MASTER SPA EQUIPMENT CBP 09/02/2022 S1ENGINEERINGASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 9225309/02/2022 S1ENGINEERINGASHER LOT 6681370 PEARY PLACE LA QUINTA, CA 9225309/02/2022