Loading...
BSOL2022-0083ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 7/15/2022 7/15/2022 ADDED DISCOVERY BUILDERS SO THEY COULD UPLOAD CORRECTIONS PER EMAIL FROM APPLICANT CONTRACTOR ATTACHED PLAN CHECK COMPLETE/READY FOR PICK UP AJ ORTEGA 3/31/2022 3/31/2022 EMAILED APPLICANT (production@nrgupgrade.com) 1ST REVIEW CORRECTIONS AND NOTICE OF INCORRECT LOGIN BEING USED TO APPLY FOR PERMIT. PLAN CHECK COMPLETE/READY FOR PICK UP AJ ORTEGA 4/21/2022 4/21/2022 EMAILED APPLICANT AND SFD CONTRACTOR (production@nrgupgrade.com; tjenkins@discoverybuildersllc.com) 2ND REVIEW CORRECTIONS. RESUBMITTAL AJ ORTEGA 4/4/2022 4/4/2022 2ND SUBMITTAL RECEIVED VIA EMAIL, VERIFIED ATTACHMENT AND CREATED REVIEW. CONDITIONS Description: LEBOWITZ / 15.3kW PV SYSTEM - (45) 340W PANELS+MICROINV/125A Type: SOLAR (WEB)Subtype: RESIDENTIAL GREATER THAN 10KW Status: FINALED Applied: 2/28/2022 EPRS Parcel No: 767710022 Site Address: 81591 BAFFIN AVE LA QUINTA,CA 92253 Approved: 5/24/2022 AOR Subdivision: TR 33076-2 Block: Lot: 109 Issued: 7/14/2022 JLIM Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/30/2023 BLAK Valuation: $20,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 15.3kW SOLAR ARRAY - (45) 340W HANWHA PANELS+ENPHASE IQ7 MICROINVERTERS W/(1) 125 AMP SUBPANEL [855SF] 2019 CALIFORNIA ELECTRICAL CODE. Printed: Friday, October 20, 2023 9:31:06 AM 1 of 6 Permit Details City of La Quinta PERMIT NUMBER BSOL2022-0083 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT B N H INC dba NRG UPGRADE 5657 WILSHIRE BLVD 340 LOS ANGELES CA 90036 (480)624-5200 PRODUCTION@NRGUP GRADE.COM CONTRACTOR B N H INC dba NRG UPGRADE 5657 WILSHIRE BLVD 340 LOS ANGELES CA 90036 (480)624-5200 PRODUCTION@NRGUP GRADE.COM CONTRACTOR 2 DISCOVERY BUILDERS CALIFORNIA INC dba DBCA INC 14605 N 73RD STREET SCOTTSDALE AZ 85260 (480)624-5200 tjenkins@discoverybuil dersllc.com LOCAL CONTACT NRGUPGRADE ASAF 5657 WILSHIR BLVD LOS ANGELES CA 90036 (480)624-5200 production@nrgupgrad e.com OWNER LEBOWITZ A&A FAMILY TRUST 1333 2ND ST STE 650 SANTA MONICA CA 90401 (480)624-5200 andy@aslhcp.com FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 7/14/22 R71284 0001 CREDIT CARD B N H INC dba NRG UPGRADE JLIM Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 PV SYSTEM GREATER THAN 10KW 101-0000-42403 0 $41.68 $41.68 7/14/22 R71284 0001 CREDIT CARD B N H INC dba NRG UPGRADE JLIM PV SYSTEM GREATER THAN 10KW PC 101-0000-42600 0 $41.68 $41.68 7/14/22 R71284 0001 CREDIT CARD B N H INC dba NRG UPGRADE JLIM Total Paid for ELECTRICAL 2021: $83.36 $83.36 PERMIT ISSUANCE 101-0000-42404 0 $105.60 $105.60 7/14/22 R71284 0001 CREDIT CARD B N H INC dba NRG UPGRADE JLIM Total Paid for PERMIT ISSUANCE: $105.60 $105.60 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/14/22 R71284 0001 CREDIT CARD B N H INC dba NRG UPGRADE JLIM Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 Printed: Friday, October 20, 2023 9:31:06 AM 2 of 6 Permit Details City of La Quinta PERMIT NUMBER BSOL2022-0083 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH ELEC DCL 7/27/2022 7/27/2022 APPROVED W/EXCEPTIO N eTRAKiT Inspection Request 7/26/2022 3:21 PM DISCOVERY BUILDERS CALIFORNIA INC dba DBCA INC Contact Name: DISCOVERY BUILDERS CALIFORNIA INC dba DBCA INC Site Address: 81591 BAFFIN AVE Phone: 7604854010 e-Mail: eaguilar@discoverybuildersllc.com - NUMBER 6 THWN-2 VERIFIED. PLAN REVISION REQUIRED FOR NUMBER 6 VERSUS NUMBER EIGHT WIRING ON APPROVED PLANS. PLEASE INCLUDE ANY OTHER ALTERATIONS TO APPROVED PLANS. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/14/22 R71284 0001 CREDIT CARD B N H INC dba NRG UPGRADE JLIM Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$205.96 $205.96 Printed: Friday, October 20, 2023 9:31:06 AM 3 of 6 Permit Details City of La Quinta PERMIT NUMBER BSOL2022-0083 SOLAR FINAL**BLAK 12/22/2022 12/22/2022 DISAPPROVE D Need to revise plans on relocate of any equipment.Breaker per plan calls for 200 amp ocpd currently 600. Revise plan.Still working on bonding will need to verify gas water ufer and panel. Plan calls for 45 panels currently 41 installed revise or install per plan.Panels not per plan currently evervolt model number EVPV 380. Plan Kohl's for Q peak duo BLK-G8Junction boxes need approved water proof adapter for bond wire side.Combiner box missing 20 amp breakers complete make up of wire. verify correct clearance and spacing from roof and secure conduit.Hi complete corrections and recall for inspection. SOLAR FINAL**BLAK 1/30/2023 1/30/2023 APPROVED eTRAKiT Inspection Request 1/27/2023 10:20 AM DISCOVERY BUILDERS CALIFORNIA INC dba DBCA INC Contact Name: DISCOVERY BUILDERS CALIFORNIA INC dba DBCA INC Site Address: 81591 BAFFIN AVE Phone: 7604854010 e-Mail: eaguilar@discoverybuildersllc.com REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS Printed: Friday, October 20, 2023 9:31:06 AM 4 of 6 Permit Details City of La Quinta PERMIT NUMBER BSOL2022-0083 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 7/15/2022 AARON HICKSON FW Permit assignment.msg FW Permit assignment.msg 0 DOC 4/4/2022 AJ ORTEGA 2ND SUBMITTAL SOLAR PLAN BSOL2022-0083 - 2ND SUBMITTAL SOLAR PLAN.pdf 1 BOND INFORMATION 1ST BLDG NS - ETRAKIT (1 DAY)AJ ORTEGA 2/28/2022 3/1/2022 3/31/2022 REVISIONS REQUIRED 1st Review Corrections: 1. Boxes and conduit bodies shall be of an approved size to provide free space for all enclosed conductors. The minimum volume for conduit bodies shall be as calculated in 314.16(C). The maximum number of conductors permitted shall be the maximum number permitted by Table 1 of Chapter 9 for the conduit or tubing to which it is attached. 2. The photovoltaic system attributes do not meet requirements for construction of the single family dwelling. 3. Signage sheet does not include “RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM” per 690.56(C)(3). 2ND BLDG NS – ETRAKIT (1 DAY)AJ ORTEGA 4/4/2022 4/5/2022 4/21/2022 REVISIONS REQUIRED The photovoltaic system attributes still do not meet requirements for construction of the single family dwelling. SFD Permit has a Revision 2 Submittal that does not match what is being proposed in this system’s design. Previous comments 1 and 3 will be reviewed when system design has been reconciled. 3RD BLDG NS – ETRAKIT (1 DAY)AJ ORTEGA 5/23/2022 5/24/2022 5/24/2022 APPROVED CLOUDED TILT OF ARRAY TO FLAT PER SFD CONTRACTOR CONFIRMING IT WAS TO BE FLAT AND THE SFD'S ENERGY CALCULATIONS BEING REVISED FOR A FLAT INSTALLATION. Printed: Friday, October 20, 2023 9:31:06 AM 5 of 6 Permit Details City of La Quinta PERMIT NUMBER BSOL2022-0083 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/24/2022 AJ ORTEGA SOLAR PLAN (APPROVED) BSOL2022-0083 - SOLAR PLAN (APPROVED).pdf 1 DOC 1/17/2023 Etrakit Contractor BSOL2022-0083 81591 Baffin As built Plans 81-591 Baffin Ave lot 109B (2) Rev B.pdf 1 DOC 2/28/2022 Etrakit Public Registration solar plans 81-591 Baffin Ave lot 109B approve.pdf 1 Printed: Friday, October 20, 2023 9:31:06 AM 6 of 6 Permit Details City of La Quinta PERMIT NUMBER BSOL2022-0083 REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-081-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502COVER SHEETSCOPE OF WORKDC SYSTEM SIZE: 15.30KWCEC AC SYSTEM SIZE: 14.19KWMODULES: (45) HANWHA Q.CELLS Q.PEAK DUO BLK-G8 340W MODULESINVERTER: (45) ENPHASE IQ7-60-2-US MICROINVERTERSRACKING: IRONRIDGE XR10 RAILATTACHMENT: IRONRIDGE TILT LEG WITH E CHEM CURBVICINITY MAPGENERAL NOTES:·LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLARPHOTOVOLTAIC INSTALLATION.·THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES·PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED·ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED·ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703, UL1741 AND UL1703·ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH ASGeoCel 2300 CLEAR SEALANT·THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTIONAND THE UTILITY IS OBTAINED·THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL,OR BUILDING ROOF VENTS·IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THENECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE·EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATIONINSTRUCTIONS"·A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH CAL-OSHAREGULATIONS·PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDEDIN THE INVERTER, AND SYSTEM COMPLIES WITH 690.35.·MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.·INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.·ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED, LABELED, AND INSTALLED PER THE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED ARECOGNIZED ELECTRICAL TESTING LABORATORY.·CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 1/2" ABOVEROOF SURFACE. NEC 310.15(B)(3)(c)·THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTANDA MINIMUM 110 MPH WIND LOAD.TABLE OF CONTENTSPAGE #DESCRIPTIONPV-0COVER SHEETPV-1SITE PLANPV-2ARRAY DETAILPV-2ASTRING LAYOUTPV-3ATTACHMENT DETAILPV-4ELECTRICAL DIAGRAMPV-5ELECTRICAL CALCULATIONPV-6PLACARDSPV-7+SPEC SHEETSBUILDING INFORMATION: TWO STORY HOUSETYPE OF CONSTRUCTION: V-BOCCUPANCY: RESIDENTIAL GROUP R - 3ROOF TYPE: FLAT ROLLED COMP..ROOF RAFTERS: 2"X4" @ 24" O.C.ELECTRICAL INFORMATIONUTILITY COMPANY: IIDMAIN SERVICE AMPERAGE: 225AARRAY TILT UP:ARRAY AZIMUTH:#1 - 22°#1 - 180°CODE SUMMARYTHIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE2019 CALIFORNIA ELECTRICAL CODE2019 CALIFORNIA RESIDENTIAL CODE2019 CALIFORNIA BUILDING CODE2019 CALIFORNIA GREEN BUILDING STANDARDS CODE2019 CALIFORNIA ENERGY CODE2019 CALIFORNIA PLUMBING CODE2019 CALIFORNIA MECHANICAL CODEALL OTHER ORDINANCES ADOPTED BY THE LOCALGOVERNING AGENCIES.FLAT, SEE REVISON 2ENERGY DOCUMENTS 05/24/202215.3kW SOLAR ARRAY -(45) 340W HANWHAPANELS+ENPHASE IQ7MICROINVERTERS W/(1)125 AMP SUBPANEL[855SF] 2019 CALIFORNIAELECTRICAL CODE.BSOL2022-0083 UM MP AC CB JB 197'- 1 1 "126'-3"179'-9"132'-10"32'-5"15'-9"14'-6"39'-8"1SITE PLANSCALE: 1/32" = 1'-0"PV-1REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-181-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502ROOF ACCESS POINT:ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOTREQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGSUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTOF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONSSUCH AS TREE LIMBS, WIRES, OR SIGNSSITE PLAN(N) ARRAY AR-01(45) HANWHA Q.CELLS Q.PEAKDUO BLK-G8 340WEXISTING DRIVEWAYROOF ACCESS POINT(E) UTILITY METER(E) MAIN SERVICE PANEL(N) AC DISCONNECT(N) IQ COMBINER BOX(N) 1" EMT CONDUIT RUN(ON ROOF)(N) JUNCTION BOX36" FIRE SETBACK (TYP.)NOTE:CONDUIT SHALL BE PAINTED TO MATCH EXISTING SURFACE.BAFFIN AVENUEPROPERTY LINEPRO P E R T Y L I N E PROPERTY LINE(E) POOL 05/24/2022BSOL2022-0083 UMMPACCB JB 17'-1 0 " 28'-8" 10'-1 0 "16'-8"36'-2"39'-0"REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-281-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#10385021ARRAY DETAILSCALE: 1/16" = 1'-0"PV-2ROOF DESCRIPTIONROOF TYPEFLAT ROLLED COMP.ROOFARRAYTILT UPAZIMUTHRAFTERSSIZERAFTERSSPACING#122°180°2"X4"24" o.c.ARRAY AREAROOF# OFMODULESARRAY AREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)#145868.955727.2515.17ARRAY DETAIL(E) FRONT YARDMODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 45 MODULESMODULE TYPE = HANWHA Q.CELLS Q.PEAK DUO BLK-G8 340WMODULE WEIGHT = 43.9 LBS / 19.9 KG.MODULE DIMENSIONS = 68.5"x 40.6" = 19.31 SFUNIT WEIGHT OF ARRAY = 2.27 PSF40.6"68.5"HANWHA Q.CELLSQ.PEAK DUO BLK-G8340W(N) IRONRIDGE XR10 RAIL (TYP.)(84) IRONRIDGE TILT LEGWITH E CHEM CURBATTACHMENT @ 48" O.C.(45) ENPHASE IQ7-60-2-USMICROINVERTERS(N) ARRAY AR-01(45) HANWHA Q.CELLS Q.PEAKDUO BLK-G8 340WROOF ACCESS POINT(E) UTILITY METER(E) MAIN SERVICE PANEL(N) AC DISCONNECT(N) IQ COMBINER BOX(N) 1" EMT CONDUIT RUN(ON ROOF)(N) JUNCTION BOX36" FIRE SETBACK (TYP.)(E) BACK YARDFLAT, SEE REVISON 2ENERGY DOCUMENTS 05/24/2022BSOL2022-0083 REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-2A81-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#10385021STRING LAYOUTPV-2ASTRING LAYOUTBILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONSOLAR PV MODULE45HANWHA Q.CELLS Q.PEAK DUOBLK-G8 340W MODULESINVERTER45ENPHASE IQ7-60-2-US (240V)INVERTERCOMBINER BOX1125A ENPHASE IQ COMBINERBOX 3, (X-IQ-AM1-240-3) WITH,ENVOY COMMUNICATION,GATEWAY]AC DISCONNECT1LOCKABLE BLADE TYPE NONFUSE AC DISCONNECT, 60A,NEMA 3R, 2P, 120/240VACATTACHMENT84IRONRIDGE TILT LEG WITH ECHEM CURB ATTACHMENTRAILS6IRONRIDGE XR10 RAIL 132"RAILS18IRONRIDGE XR10 RAIL 168"RAIL SPLICE16SPLICE KITMID CLAMPS82MID CLAMPEND CLAMPS16END CLAMPGROUNDING LUG4LUG(45) HANWHA Q.CELLS Q.PEAK DUO BLK-G8 340W MODULE(45) ENPHASE IQ7-60-2-US MICROINVERTERS(3) BRANCH OF 15 MODULES CONNECTED IN SERIES.SCALE: 1/16" = 1'-0"BRANCH #1(E) FRONT YARDROOF ACCESS POINT36" FIRE SETBACK (TYP.)(E) BACK YARDBRANCH #2BRANCH #3 05/24/2022BSOL2022-0083 REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-381-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502ATTACHMENTDETAILS2ATTACHMENT DETAIL (enlarged section view)PV-3SCALE: NTS1ATTACHMENT DETAILPV-3SCALE: NTSSEE (2/PV-3) FORENLARGED VIEWPV MODULE(E) FLAT ROLLED COMP.PV MODULEL-FOOT2"X4" RAFTERS @ 24" O.C.SS BOLT & NUT5/16"x3" SS LAG BOLT WITH MIN2-1/2" THREAD EMBEDMENT,SEALED PENETRATIONGROUNDING MID/END CLAMP(N) IRONRIDGE XR10 RAIL (TYP.)IRONRIDGE FLASHING2"X4" RAFTERS @ 24" O.C.IRONRIDGE 4"STANDOFF 05/24/2022BSOL2022-0083 INTERCONNECTION120% RULE - NEC 705.12(D)(2)UTILITY FEED + SOLAR BACKFEED200A + 60A = 260ASERVICE INFOUTILITY PROVIDER:MAIN SERVICE VOLTAGE:MAIN PANEL BRAND:MAIN SERVICE PANEL:MAIN CIRCUIT BREAKER RATING:MAIN SERVICE LOCATION:IID240VN/A225A200ANORTH WEST WALLUNDERGROUNDBUSS RATING x 120%225A x 120% = 270ASERVICE FEED SOURCE:REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-481-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502ELECTRICALLINE DIAGRAM(45) HANWHA Q.CELLS Q.PEAK DUO BLK-G8 340W MODULE(45) ENPHASE IQ7-60-2-US MICROINVERTERS(3) BRANCH OF 15 MODULES CONNECTED IN SERIES.PV-41PV-4ELECTRICAL LINE DIAGRAMSCALE: NTSBRANCH #3 OF 15 MODULES(N) LOCKABLE BLADE TYPENON FUSE AC DISCONNECT,60A, NEMA 3R, 2P,120/240VAC(N) 125A ENPHASE IQCOMBINER BOX 3,(X-IQ-AM1-240-3) WITH,ENVOY COMMUNICATION,GATEWAY20A15 ENPHASE IQ7-60-2-US MICROINVERTERS(3) #6 AWG THWN-2(1) #8 AWG CU GND3/4" EMT CONDUITJUNCTION BOX600 V, NEMA 3UL LISTED(4" X 112")TO UTILITY GRIDMGN(E) MAIN SERVICE PANEL,225A RATED, 240V(N) 60A PV BREAKER ATOPPOSITE END OF BUSFROM MAIN BREAKER60AUTILITY - IID(E) MAIN BREAKER TOHOUSE 200A/2P, 240V(TOP FED)1" EMT CONDUIT(3) #8 AWG THWN-2 + Red(3) #8 AWG THWN-2 - Black(1) #8 AWG THWN-2 GND15AQ CABLE: - BLACK L1, RED L2(1) #6 BARE COPPER GNDBRANCH #2 OF 15 MODULES15 ENPHASE IQ7-60-2-US MICROINVERTERS20AENVOY BRANCH #1 OF 15 MODULES15 ENPHASE IQ7-60-2-US MICROINVERTERS20ASOLAR MODULE SPECIFICATIONSMANUFACTURER /MODEL #VMPIMPVOCISCHANWHA Q.CELLS: Q.PEAK DUO BLK-G8340WMODULE DIMENSION34.34V9.90A40.70V10.40A68.5"L x 40.6"W x 1.26"D (In Inch)MODULE TEMPERATURE COEFFICIENT OF Voc-0.27V/°CENPHASE IQ7-60-2-US MICROINVERTERInput Data (DC)Recommended Input Power (STC)Maximum Input DC VoltagePeak Power Tracking VoltageOperating RangeMin. / Max. Start VoltageMax DC Short Circuit CurrentOutput Data (AC)Maximum Output PowerNominal Output CurrentNominal Voltage / RangeNominal Frequency / RangeExtended Frequency / RangePower Factor at rated powerMaximum unit per 20A Branch Circuit235-350W +48V27V-37V16V-48V22V / 48V15A240W1A240V/211-264V60 Hz47-68 Hz1.016 (240 VAC) 05/24/2022BSOL2022-0083 REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-581-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502ELECTRICALCALCULATIONELECTRICAL NOTES1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLETO THE NEAREST RIDGE, HIP, OR VALLEY.3.) WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.4.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.5.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.6.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.7.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.8.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.9.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVEAC CONDUCTOR AMPACITY CALCULATIONS:FROM MICRO INVERTER TO IQ COMBINER BOXAMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUITPER NEC 310.15(B)(2)(c): + 22°EXPECTED WIRE TEMP (°C): 44° + 22°TEMP CORRECTION PER TABLE 310.15: 0.58#OF CURRENT CARRYING CONDUCTORS: 6CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.80CIRCUIT CONDUCTOR SIZE: 8 AWGCIRCUIT CONDUCTOR AMPACITY: 55AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B):1.25 X MAX AC OUTPUT CURRENT X # OF INVERTERS PER STRINGBRANCH #1, #2 & #3 : 1.25 X 1.00 X 15 = 18.75ADERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15TEMP CORR. PER NEC TABLE 310.15 XCONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) XCIRCUIT CONDUCTOR AMPACITY = 0.58 X 0.80 X 55 = 25.52AAC CONDUCTOR AMPACITY CALCULATIONS:FROM IQ COMBINER BOX TO MSPEXPECTED WIRE TEMP (°C): 44°TEMP CORRECTION PER NEC TABLE 310.15: 0.87CIRCUIT CONDUCTOR SIZE: 6 AWGCIRCUIT CONDUCTOR AMPACITY: 75A#OF CURRENT CARRYING CONDUCTORS: 3CONDUIT FILL PER NEC 310.15(B)(2)(A): 1REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B):1.25 X OUTPUT CURRENT OF LOAD CENTER1.25 X 1.00 X 45 = 56.25ADERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15:TEMP CORR. PER NEC 310.15 XCONDUIT FILL CORR. PER NEC 310.15(B)(2)(A) XCIRCUIT CONDUCTOR AMPACITY =0.87 X 1.00 X 75 = 65.25ANUMBER OF CURRENTCARRYING CONDUCTORS INEMT4-67-910-20PERCENT OFVALUES.80.70.50AMBIENT TEMPERATURE SPECSAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP-5°44°CONDUIT HEIGHT0.5"ROOF TOP TEMP66°CONDUCTOR TEMPERATURE RATE90° 05/24/2022BSOL2022-0083 UMMPACCBJBREVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-681-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502PLACARDSLABEL LOCATION:MAIN SERVICE PANELPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNCAUTION:81-591 BAFFIN AVENUE, LA QUINTA, CA 92253NOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2008 ARTICLE110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, ORIF REQUESTED BY THE LOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVEWORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRINGMETHOD AND SHALL NOT BE HAND WRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENTINVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETYSIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.(E) MAIN SERVICE PANELWITH UTILITY METERSOLAR PANELON ROOF(N) IQ COMBINER BOX(N) AC DISCONNECTLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: CEC690.54)LABEL LOCATION:CONDUIT, COMBINER BOX(PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4)WARNING: PHOTOVOLTAICPOWER SOURCEWARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTIONPER CODE: CEC 690.17(E), CBDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 56.25 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTS!PHOTOVOLTAIC SYSTEM EQUIPPEDWITH RAPID SHUTDOWN DISCONNECTLABEL LOCATION:SERVICE DISCONNECTING(PER CODE: NEC 690.56(C))SOURCES: UTILITY GRIDAND PV SOLAR ELECTRICSYSTEMDUAL POWER SUPPLYWARNING!NOTICEPV SYSTEM COMBINER PANELDO NOT ADD LOADS TO THIS PANELLABEL LOCATION:LOAD CENTER[Only use when applicable for PV load center]TURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUTDOWN PV SYSTEM ANDREDUCESHOCK HAZARD IN THEARRAYSOLAR ELECTRICPV PANELSLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.56(C)(1)(A))SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNLABEL LOCATION:UTILITY SERVICE METER AND MAIN SERVICEPANEL.PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b)WARNINGPOWER SOURCE OUTPUT CONNECTION DONOT RELOCATE THIS OVERCURRENTDEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: CEC 705.12(B)(2)(3)(b))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]!LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: CEC 705.12(B)(2)(3)(b)) WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM ARE UNGROUNDEDAND MAY BE ENERGIZEDLABEL LOCATION:DC DISCONNECT, INVERTER(PER CODE: CEC 690.35(F))[To be used when inverter is ungrounded]!WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTIONPER CODE: CEC 690.17(E). CB!RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:RSD SWITCH PER CODE: 690.56(C)(3) 05/24/2022BSOL2022-0083 REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-781-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-881-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-981-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-1081-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-1181-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-1281-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-1381-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-1481-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSPV-1581-591 BAFFIN AVE 81-591 BAFFIN AVENUE, LA QUINTA, CA 92253CONTRACTOR SIGNATURENRG UPGRADE5657 WILSHIRE BLVD, LOS ANGELES, CA 90036(844)-674-8787CSLB#1038502DATA SHEET