Loading...
BPOL2021-0117ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL DUANE CLAYTON 4/28/2021 4/28/2021 - INFORMED APPLICANT THAT PLAN REVIEW IS COMPLETE AND REQUIRES REVISIONS. E-MAIL DUANE CLAYTON 4/28/2021 4/28/2021 - CONTACTED APPLICANT AND REQUESTED THAT A SINGLE PDF FILE WITH ENTIRE PLAN SET BE UPLOADED TO TRAKIT FOR REVIEW. E-MAIL DUANE CLAYTON 4/29/2021 4/29/2021 - REQUESTED A COMPLETE SECOND SUBMITTAL REVISED PLAN SET FROM STOKER POOLS. E-MAIL DUANE CLAYTON 4/29/2021 4/29/2021 - INFORMED APPLICANT THAT 2ND PLAN REVIEW IS COMPLETE AND REQUIRES REVISIONS. E-MAIL DUANE CLAYTON 4/30/2021 4/30/2021 - INFORMED STOKER POOLS THAT PLAN REVIEW IS COMPLETE AND APPROVED. Description: ASHER / POOL/SPA AT REAR YARD WITH ENTRY WF Type: POOL CONSTRUCTION (WEB) Subtype: PRIVATE Status: FINALED Applied: 4/9/2021 ECON Parcel No: 767710013 Site Address: 81560 BAFFIN AVE LA QUINTA,CA 92253 Approved: 4/30/2021 DCL Subdivision: TR 33076-2 Block: Lot: 100 Issued: 4/30/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/22/2022 DCL Valuation: $200,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: POOL AND SPA AT REAR YARD WITH WATER FEATURE AT ENTRY COURTYARD [JEREMY WELTON ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. SPECIAL INSPECTIONS REQUIRED PER ENGINEERING (SEE S-1).THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURES. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Printed: Friday, October 20, 2023 10:56:38 AM 1 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT F P D SERVICES INC DBA STOKER POOLS 77-799 Jackal Drive, Palm Desert, CA, USA, Ste #B Palm Desert CA 92211 (760)772-1111 accounting@stokerpoo ls.com CONTRACTOR F P D SERVICES INC DBA STOKER POOLS 43653 PARKWAY ESPLANADE EAST LA QUINTA CA 92253 (760)772-1111 ACCOUNTING@STOKE RPOOLS.COM OWNER Gal Asher 81560 Baffin Ave La Quinta CA 92253 (760)772-1111 CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST DUANE CLAYTON 4/28/2021 4/29/2021 COMPLETE - SEE READY TO ISSUE CHECKLIST. E-MAIL DUANE CLAYTON 6/22/2022 6/22/2022 - CONTRACTOR PROVIDED SITE PICTURES VIA EMAIL, WHICH ADDRESSED THE REMAINING FINAL INSPECTION CORECTIONS. NOTE DUANE CLAYTON 4/29/2021 4/29/2021 - SECOND SUBMITTAL RECEIVED BUT IS INCOMPLETE. SHEETS ARE MISSING. REVIEW TO BE SCHEDULED WHEN COMPLETE PLAN SET IS UPLOADED. NOTE DUANE CLAYTON 4/29/2021 4/29/2021 - 2ND SUBMITTAL RECEIVED FROM APPLIANT. 2ND ONE-DAY REVIEW SCHEDULED. RESUBMITTAL DUANE CLAYTON 4/30/2021 4/30/2021 - APPLICANT UPLOADED 3RD SUBMITTAL PLAN SET. 3RD ONE-DAY REVIEW SCHEDULED. CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.25 $40.25 $40.25 4/30/21 WEB8103 02256D CREDIT F P D SERVICES INC DBA STOKER POOLS ECON Total Paid for BLDG CITY STAFF - PER HOUR: $40.25 $40.25 Printed: Friday, October 20, 2023 10:56:38 AM 2 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES UNDERGROUND PLBG DCL 5/4/2021 5/4/2021 PARTIALLY APPROVED eTRAKiT Inspection Request 4/30/2021 4:14 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $8.00 $8.00 4/30/21 WEB8103 02256D CREDIT F P D SERVICES INC DBA STOKER POOLS ECON Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $8.00 $8.00 DETACHED SPA/WATER FEATURE/OTHER 101-0000-42404 0 $201.25 $201.25 4/30/21 WEB8103 02256D CREDIT F P D SERVICES INC DBA STOKER POOLS ECON SWIMMING POOL/SPA 101-0000-42404 0 $201.25 $201.25 4/30/21 WEB8103 02256D CREDIT F P D SERVICES INC DBA STOKER POOLS ECON SWIMMING POOL/SPA PC 101-0000-42600 0 $109.48 $109.48 4/30/21 WEB8103 02256D CREDIT F P D SERVICES INC DBA STOKER POOLS ECON Total Paid for POOL / SPA 2019: $511.98 $511.98 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 4/30/21 WEB8103 02256D CREDIT F P D SERVICES INC DBA STOKER POOLS ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 4/30/21 WEB8103 02256D CREDIT F P D SERVICES INC DBA STOKER POOLS ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$575.23 $575.23 Printed: Friday, October 20, 2023 10:56:38 AM 3 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 UNDERGROUND PLBG DCL 5/4/2021 5/4/2021 PARTIALLY APPROVED eTRAKiT Inspection Request - FROM POOL SHELL TO SOUTHEAST CORNER. UNDERGROUND ELEC DCL 5/4/2021 5/4/2021 PARTIALLY APPROVED eTRAKiT Inspection Request 4/30/2021 4:14 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - FROM POOL SHELL TO SOUTHEAST CORNER. PRE-GUNITE DCL 5/4/2021 5/4/2021 PARTIALLY APPROVED eTRAKiT Inspection Request 4/30/2021 4:14 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - POOL ONLY. REQUEST INSPECTION FOR WATER FEATURE WHEN READY.- STRUCTURAL OBSERVATION FOR STEEL PLACEMENT REQUIRED. UNDERGROUND PLBG AMOR 10/7/2021 10/7/2021 APPROVED eTRAKiT Inspection Request 10/6/2021 1:23 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM 1. WATER FEATURE PLB OK. Printed: Friday, October 20, 2023 10:56:38 AM 4 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 UNDERGROUND ELEC AMOR 10/7/2021 10/7/2021 APPROVED eTRAKiT Inspection Request 10/6/2021 1:23 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM 1. WATER FEATURE CONDUITS OK PRE-GUNITE AMOR 10/7/2021 10/7/2021 DISAPPROVE D eTRAKiT Inspection Request 10/6/2021 1:23 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM 1. MISSING NUMBER THREE DOWES INTO EXISTING FOOTING. PRE-GUNITE BLD 10/13/2021 10/13/2021 APPROVED PRE-GUNITE DCL 10/13/2021 10/13/2021 DISAPPROVE D - PER APPROVED PLANS, STRUCTURAL OBSERVATION OF STEEL PLACEMENT REQUIRED FOR POOL, SPA, AND WATER FEATURE. EOR REQUIRED TO CLARIFY REQUIREMENT.- PROVIDE DETAIL FOR PROPOSED GUNITE WALL AT ENTRY WATER FEATURE.- SPECIAL INSPECTION REPORTS FOR PLACEMENT AND STRENGTH OF GUNITE REQUIRED NO LATER THAN PRE-PLASTER INSPECTION. SEE SPECIAL INSPECTIONS TABLE ON SHEET S-1. Printed: Friday, October 20, 2023 10:56:38 AM 5 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 DECK BOND DCL 11/12/2021 11/12/2021 APPROVED eTRAKiT Inspection Request 11/10/2021 11:57 AM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM UNDERGROUND GAS DCL 12/15/2021 12/15/2021 PARTIALLY APPROVED eTRAKiT Inspection Request 12/14/2021 2:36 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - FROM EQUIPMENT LOCATION TO EAST SIDE YARD. CALL IN UNDERGROUND INSPECTION FROM EAST SIDE YARD TO GAS METER WHEN READY. UNDERGROUND ELEC DCL 12/15/2021 12/15/2021 APPROVED eTRAKiT Inspection Request 12/14/2021 2:36 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - FROM EQUIPMENT LOCATION TO ELECTRICAL PANEL. FULL UNDERGROUND ELECTRICAL APPROVAL. Printed: Friday, October 20, 2023 10:56:38 AM 6 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 PRE-PLASTER JFU 2/11/2022 2/11/2022 CANCELED eTRAKiT Inspection Request 2/10/2022 12:53 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM FINAL**DCL 5/31/2022 5/31/2022 DISAPPROVE D eTRAKiT Inspection Request 5/27/2022 2:30 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - NO PRE-PLASTER INSPECTION APPROVAL.- UNDERGROUND GAS RUN FROM EAST SIDE YARD TO METER COVERED WITHOUT GAS TEST OR UNDERGROUND INSPECTION.- PROVIDE ACCESS BEHIND POOL SUB-PANEL DEAD FRONTS FOR WIRING INSPECTION. ADDITIONAL CORRECTIONS MAY APPLY.- DOOR ALARMS REQUIRED AT ALL EGRESS DOORS WITH DIRECT POOL ACCESS.- PROVIDE BUSHINGS AT UNUSED KNOCKOUTS AT EAST SIDE YARD EQUIPMENT LOCATION.- UNABLE TO VERIFY GROUNDING AT SUB-PANELS. Printed: Friday, October 20, 2023 10:56:38 AM 7 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 PRE-PLASTER DCL 6/1/2022 6/1/2022 APPROVED eTRAKiT Inspection Request 5/31/2022 2:29 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM FINAL**DCL 6/1/2022 6/22/2022 APPROVED eTRAKiT Inspection Request 5/31/2022 3:27 PM F P D SERVICES INC DBA STOKER POOLS Contact Name: F P D SERVICES INC DBA STOKER POOLS Site Address: 81560 BAFFIN AVE Phone: 7607721111 e-Mail: ACCOUNTING@STOKERPOOLS.COM - PROVIDE GFCI PROTECTION AT POOL PUMPS.- BOND POOL SUB PANELS.- NUMBER SIX WIRE UNDERSIZED FOR 60 AMP BREAKER.- PROVIDE BUSHINGS AT UNUSED KNOCK OUTS AT MAIN POOL PANEL CHASE AND WATER FEATURE SUB PANEL. - STATUS UPDATED TO APPROVED FOR FINAL. SEE ATTACHMENTS. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG NS - ETRAKIT (1 DAY) DUANE CLAYTON 4/9/2021 4/12/2021 4/28/2021 REVISIONS REQUIRED - SEE 1ST REVIEW PLAN SET WITH CORRECTIONS IN ATTACHMENTS. 2ND BLDG NS – ETRAKIT (1 DAY) DUANE CLAYTON 4/29/2021 4/30/2021 4/29/2021 REVISIONS REQUIRED - SEE SITE PLAN WITH CORRECTIONS IN ATTACHMENTS. PARENT PROJECTS Printed: Friday, October 20, 2023 10:56:38 AM 8 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/28/2021 DUANE CLAYTON 1ST SUBMITTAL - PLAN SET BPOL2021-0117 - 1ST SUBMITTAL - PLAN SET.pdf 1 DOC 4/28/2021 DUANE CLAYTON HOA APPROVAL BPOL2021-0117 - HOA APPROVAL.pdf 1 DOC 4/28/2021 DUANE CLAYTON 1ST REVIEW - PLAN SET (CORRECTIONS) BPOL2021-0117 - 1ST REVIEW - PLAN SET (CORRECTIONS).pdf 1 DOC 4/29/2021 DUANE CLAYTON 2ND SUBMITTAL - PLAN SET BPOL2021-0117 - 2ND SUBMITTAL - PLAN SET.pdf 1 DOC 4/29/2021 DUANE CLAYTON 2ND REVIEW - PLAN SET (CORRECTIONS) BPOL2021-0117 - 2ND REVIEW - PLAN SET (CORRECTIONS).pdf 1 DOC 4/30/2021 DUANE CLAYTON 3RD SUBMITTAL PLAN SET BPOL2021-0117 - 3RD SUBMITTAL PLAN SET_1.pdf 1 DOC 4/30/2021 DUANE CLAYTON PLAN SET (APPROVED)BPOL2021-0117 - PLAN SET (APPROVED).pdf 1 DOC 6/22/2022 DUANE CLAYTON EMAIL WITH SITE PICTURES BPOL2021-0117 - EMAIL WITH SITE PICTURES.pdf 1 BOND INFORMATION 3RD BLDG NS – ETRAKIT (1 DAY) DUANE CLAYTON 4/30/2021 5/3/2021 4/30/2021 APPROVED - SEE APPROVED PLAN SET IN ATTACHMENTS. Printed: Friday, October 20, 2023 10:56:38 AM 9 of 9 Permit Details City of La Quinta PERMIT NUMBER BPOL2021-0117 SHEET INDEXVICINITY MAP A CUSTOM POOL AND SPA FOR LOT 100B 81-560 BAFFIN AVE. LA QUINTA, CA GENERAL NOTES TITLE SP-1.0 COVER SHEET SP-2.0 SITE PLAN SP-3.0 ENLARGED POOL PLAN SP-3.1 POOL SECTIONS SP-3.2 PLUMBING PLAN SP-4.0 WATER FEATURE PLAN, PLUMBING PLAN & SECTION SP-5.0 EQUIPMENT LAYOUT S-1 STRUCTURAL NOTES S-2 DETAILS NO. ABBREVIATIONS REFERENCE SYMBOLS CITY OF LA QUINTA NOTES SHEET NO SHEET NO 14 1 SHEET NO F-1 J 01 GENERAL NOTES: 1. PROPOSED CONSTRUCTION WILL CONFORM TO THE CURRENT CODES (CBC 106.1.1) 2019 California Residential Code, Title 24 Part 2.5 2019 California Electrical Code, Title 24 Part 3 2019 California Mechanical Code, Title 24 Part 4 2019 California Plumbing Code, Title 24 Part 5 2019 California Energy Code, Title 24 Part 6 2019 California Fire Code, Title 24 Part 9 2. GOVERNMENT CODE SECTION 4216.2. (A) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR TO COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND, IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER SUITABLE MARKINGS THE AREA TO BE EXCAVATED. 3. THE CITY BUILDING INSPECTOR HAS THE AUTHORITY TO REQUEST FULLY REVISED PLAN SHEETS WITH ALL FIELD CHANGES CLOUDED WITH DELTAS TO BE SUBMITTED FOR CITY PLAN REVIEW WHEN HE/SHE DETERMINES THE NUMBER OF FIELD REVISIONS WARRANT SUCH A REQUEST. ELECTRICAL NOTES: 1. THE EQUIPMENT BONDING GRID SHALL EXTEND UNDER PAVED AND UNPAVED SURFACES FOR 3 FEET HORIZONTALLY BEYOND THE INSIDE WALLS OF THE POOL. 2. ALL METAL-SHEATHED CABLES AND RACEWAYS, METAL PIPING, AND ALL FIXED METAL PARTS THAT ARE WITHIN THE FOLLOWING DISTANCES OF THE POOL, EXCEPT THOSE SEPARATED FROM THE POOL BY A PERMANENT BARRIER, SHALL BE BONDED: A.) WITHIN 5 FEET HORIZONTALLY OF THE INSIDE WALLS OF THE POOL. B.) WITHIN 12 FEET MEASURED VERTICALLY ABOVE THE MAXIMUM WATER LEVEL OF THE POOL, OR ANY SLIDES, DIVING BOARDS ETC... 3. PROVIDE 36" WORKING CLEARANCES FOR THE POOL EQUIPMENT DISCONNECT AND SUB PANEL (CEC ART 110.26) 4. LOAD CALCS - USE EXISTING ELECTRICAL FEED TO POOL EQUIPMENT 5. SINGLE LINE DIAGRAM - SEE BUILDING PERMIT AND APPROVED PLANS 6. NO OVERHEAD UTILITY/SERVICE LINES ARE IN THE VICINITY OF THE NEW POOL OR SPA 7. ALL OUTLETS SUPPLIED BY SINGLE PHASE, 15A AND 20A, 125V OR 240V BRANCH CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION. THIS APPLIES TO OUTLETS REGARDLESS OF THEIR PROXIMITY TO THE SWIMMING POOL AND IT APPLIES TO CORD-AND-PLUG CONNECTED AND DIRECT CONNECTED SWIMMING POOL PUMP MOTORS. CEC 680.22 (B) MECHANICAL/PLUMBING NOTES: 1. ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS. 2. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED. 3. GAS ISOMETRIC: - NEW 2" PE GAS LINE WITH TRACER WIRE, ±100 LINEAL FEET. 2019 ENERGY EFFICIENCY STANDARDS MANDATORY MEASURES (MF-1R) 1. ANY POOL OR SPA HEATING SYSTEM SHALL BE CERTIFIED TO HAVE: A THERMAL EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AN ON-OFF SWITCH MOUNTED OUTSIDE OF THE HEATER; A PERMANENT WEATHERPROOF PLATE OR CARD WITH OPERATING INSTRUCTIONS; AND SHALL NOT USE ELECTRIC RESISTANCE HEATING OR A PILOT LIGHT. 2. ANY POOL OR SPA HEATING EQUIPMENT SHALL BE INSTALLED WITH AT LEAST 36" OF PIPE BETWEEN FILTER AND HEATER, OR DEDICATED SUCTION AND RETURN LINES, OR BUILT-UP CONNECTIONS FOR FUTURE SOLAR HEATING. 3. OUTDOOR POOLS OR SPAS THAT HAVE A HEAT PUMP OR GAS HEATER SHALL HAVE A COVER. 4. POOLS SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL WATER, AND A TIME SWITCH THAT WILL ALLOW ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIODS. 5. RESIDENTIAL POOL SYSTEMS OR EQUIPMENT MUST MEET THE PUMP SIZING, FLOW RATE, PIPING AND FILTERS. EQUIPMENT NOTES/MANDATORY REQUIREMENTS 1. ANY POOL OR SPA HEATING SYSTEM OR EQUIPMENT MAY BE INSTALLED ONLY IF THE MANUFACTURER HAS CERTIFIED THAT THE SYSTEM OR EQUIPMENT HAS ALL OF THE FOLLOWING: EFFICIENCY - A THERMAL EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AND ON-OFF SWITCH - A READILY ACCESSIBLE ON-OFF SWITCH, MOUNTED ON THE OUTSIDE OF THE HEATER THAT ALLOWS SHUTTING OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING; AND INSTRUCTIONS - A PERMANENT, EASILY READABLE , AND WEATHERPROOF PLATE OR CARD THAT GIVES INSTRUCTION FOR THE ENERGY EFFICIENT OPERATION OF THE POOL OR SPA HEATER AND FOR THE PROPER CARE OF POOL OR SPA WATER WHEN A COVER IS USED; AND ELECTRIC RESISTANCE HEATING - NO ELECTRIC RESISTANCE HEATING; AND 1.1. EXCEPTION 1 TO SECTION 114 (A)4: LISTED PACKAGE UNITS WITH FULLY INSULATED ENCLOSURE, AND WITH TIGHT-FITTING COVERS THAT ARE INSULATED TO AT LEAST R-6. 1.2. EXCEPTION 2 TO SECTION 114(A)4: POOLS OR SPAS DERIVING AT LEAST 60 PERCENT OF THE ANNUAL HEATING ENERGY FROM SITE SOLAR ENERGY OR RECOVERED ENERGY. 2. ANY POOL OR SPA SYSTEM OR EQUIPMENT SHALL BE INSTALLED WITH ALL OF THE FOLLOWING: PIPING - SEE MANDATORY MEASURES NOTE #2 COVERS - SEE MANDATORY MEASURES NOTE #3 DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS - SEE MANDATORY MEASURES NOTE #4 3. ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03 FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO FINAL INSPECTION APPROVAL, 4. DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS. IF THE SYSTEM OR EQUIPMENT IS FOR A POOL: 4.1. THE POOL SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL WATER; AND 4.2. A TIME SWITCH OR SIMILAR CONTROL MECHANISM SHALL BE INSTALLED AS PART OF THE POOL WATER CIRCULATION CONTROL SYSTEM THAT WILL ALLOW ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIOD, AND FOR THE MINIMUM TIME NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC HEALTH STANDARDS. 5. ALL PUMPS AND PUMP MOTORS INSTALLED SHALL BE LISTED IN THE COMMISSIONS'S DIRECTORY OF CERTIFIED EQUIPMENT AND SHALL COMPLY WITH THE APPLIANCE EFFICIENCY REGULATIONS. 6. FILTRATION PUMPS SHALL BE SIZED, OR IF PROGRAMMABLE, SHALL BE PROGRAMMED, SO THAT THE FILTRATION FLOW RATE IS NOT GREATER THAN THE RATE NEEDED TO TURN OVER THE POOL WATER VOLUME IN 6 HOURS OR 36 GPM, WHICHEVER IS GREATER. 7. PUMP MOTORS USED FOR FILTRATION WITH A CAPACITY OF 1 HP OR MORE SHALL BE MULTI SPEED. 8. EACH AUXILIARY POOL LOAD SHALL BE SERVED BY EITHER SEPARATE PUMPS OR THE SYSTEM SHALL BE SERVED BY A MULTI SPEED PUMP. EXCEPTION - PUMPS LESS THAN 1 HP MAY BE SINGLE SPEED. 9. MULTI SPEED PUMPS SHALL HAVE CONTROLS WHICH DEFAULT TO THE FILTRATION FLOW RATE WHEN NO AUXILIARY POOL LOADS ARE OPERATING. 10. FOR MULTI SPEED PUMPS, THE CONTROLS SHALL DEFAULT TO THE FILTRATION FLOW SETTING WITHIN 24 HOURS AND SHALL HAVE AN OVERRIDE CAPABILITY FOR SERVICING. 11. A LENGTH OF STRAIGHT PIPE THAT IS GREATER THAN OR EQUAL TO AT LEAST 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE THE PUMP. 12. POOL PIPING SHALL BE SIZED SO THAT THE VELOCITY OF THE WATER AT MAXIMUM FLOW FOR AUXILIARY POOL LOADS DOES NOT EXCEED 8 FEET PER SECOND IN THE RETURN LINE AND 6 FEET PER SECOND IN THE SUCTION LINE. 13. ALL ELBOWS SHALL BE SWEEP ELBOWS OR ELBOW-TYPE THAT HAVE A PRESSURE DROP OF LESS THAN THE PRESSURE DROP OF STRAIGHT PIPE WITH A LENGTH OF 30 PIPE DIAMETERS. 14. FILTERS SHALL BE AT LEAST THE SIZE SPECIFIED IN NSF/ANSI 50 FOR PUBLIC POOL INTENDED. 15. MINIMUM DIAMETER OF BACKWASH VALVES SHALL BE 2 INCHES OF THE DIAMETER OF THE RETURN PIPE, WHICHEVER IS GREATER. SAFETY STANDARDS SECTION AV100.3 OF THE 2016 C.R.C. ADDRESSES THE POOL SAFETY STANDARDS FOR POOLS, SPAS AND HOT TUBS INSTALLED FOR SINGLE FAMILY RESIDENCE. FOR THE PURPOSE OF THIS CODE THE FOLLOWING DEFINITIONS ARE APPLICABLE: SWIMMING POOL: ANY STRUCTURE INTENDED FOR SWIMMING OR RECREATIONAL BATHING THAT CONTAINS WATER OVER 18 INCHES DEEP. ENCLOSURE: A FENCE, WALL, OR OTHER BARRIER THAT ISOLATES A SWIMMING POOL FROM ACCESS TO THE HOME ENCLOSURE REQUIREMENTS: AN OUTDOOR SWIMMING POOL, INCLUDING HOT TUBS OR SPAS SHALL BE SURROUNDED BY A BARRIER WHICH SHALL COMPLY WITH THE FOLLOWING: 1. TOP OF THE BARRIER SHALL BE AT LEAST 60 INCHES ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL 1.1. OPENINGS IN TECH BARRIER SHALL NOT ALLOW THE PASSAGE OF A 4 INCH DIA. SPHERE. 1.2. OPENING BETWEEN THE FINISH GRADE AND THE BOTTOM OF THE BARRIER SHALL BE MAX. 2 INCHES. 1.3. BARRIERS SHALL BE INSTALLED SO AS NOT HAVE ANY FEATURES WHICH AID IN CLIMBING. 2. ACCESS GATES SHALL BE A MINIMUM OF 60 INCHES ABOVE GRADE AND SHALL BE SELF CLOSING AND HAVE SELF LATCHING DEVICE. GATES MUST OPEN OUTWARD FROM THE POOL. GATES SHALL MEET THE SAME PROVISIONS AS LISTED AS BARRIERS. 3. OUTSIDE SURFACES SHALL BE FREE OF ANYTHING THAT CAN MAKE THE BARRIER CLIMBABLE 4. IF USING THE WALL OF THE HOUSE AS AN ENCLOSURE, EXIT ALARMS MUST BE PLACE ON ALL DOORS THAT PROVIDE DIRECT ACCESS TO THE POOL. SUCTION OUTLETS: 1. POOLS AND SPAS MUST HAVE AT LEAST TWO CIRCULATION OUTLETS, WHICH ARE HYDRAULICALLY BALANCED AND SEPARATED BY THREE FEET OR 2. UTILIZATION OF SKIMMERS, PERIMETER OVERFLOW SYSTEMS, OR OTHER PRE-APPROVED DEVICES IN LIEU OF TRADITIONAL SUCTION DEVICES. 3. THE USE OF OTHER OUTLET DEVICES WHICH MAY MEET ANSI/APSP-7 STANDARDS BUT DO NOT HAVE A MINIMUM OF THREE FEET BETWEEN OUTLETS IS PROHIBITED. SCOPE OF WORK 1. NEW REAR YARD POOL & SPA. 2. NEW ENTRY WATER FEATURE. 1 SP-1.0COVER SHEETN.T.S. SHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE.LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-29-2021 dateno.revisions 1 1ST PLAN CHECK 04.29.21 CBP BPOL2021-0117 - 81560 BAFFIN ASHER / POOL, SPA AND ENTRY WATER FEATURE POOL AND SPA AT REAR YARD WITH WATER FEATURE AT ENTRY COURTYARD [JEREMY WELTON ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. SPECIAL INSPECTIONS REQUIRED PER ENGINEERING (SEE S-1).THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURES. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. 04/30/2021 Safety Features – New pools and spas shall be equipped with at least two of the following drowning prevention safety features. (H&S § 115922 – SB No. 442) • Enclosure that isolates the pool or spa from dwelling. • Removable Mesh fencing, a gate that is self-latching and closing and can accommodate a key lockable device. • Safety pool cover. • Exit alarms on doors that provide direct access to pool or spa. • A self-closing self latching device placed on doors providing direct access to pool or spa. • An alarm that when placed in a pool or spa, will sound upon detection. (Surface Motion, Pressure, Sonar, Laser) BAFFIN AVEPOOL SPA PROPERTY LINE EQUIP. RESIDENCE EQUIP. TRASH PROPERTY LINEPROPERTY LINEFIRE PIT BBQ FIRE PIT A SP-3.0 17'-2"23'-1"24'-7"23'-9"A SP-4.0 WATER FEATURE15'-4"7'-10"14'-6"11'-0"48'-6"15'-9" A SP-5.0 D SP-5.0 (3) 2" P.E. GAS LINE W/ TRACER WIRE +/-50' 30X36 CLR 30X36 CLR2'-8"2'-8"16'-11"15'-10" 1 1 30X36 CLR 2 WATER SPEC'S POOL SIZE DEPTH PERIMETER AREA VOLUME TROUGH SIZE DEPTH PERIMETER AREA VOLUME 48'-6"x71'-5" 3'-6" TO 5'-0" 244 I.F. 2,171 S.F. 65,000 GAL. 1'-6x43'-0" 30" 89 I.F. 65 S.F. 1,100 GAL. SPA @ POOL SIZE DEPTH PERIMETER AREA VOLUME 10'x22'-0" 3'-6" 64 I.F. 242 S.F. 5,000 GAL. ENTRY WATER FEATURE SIZE DEPTH PERIMETER AREA VOLUME 8'-0"x26'-0" 36" 68 I.F. 208 S.F. 4,400 GAL. SITE PLAN SCALE: 1/8"=1'-0"SITE PLANSP-2.0 1/8"=1'-0" SHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE.LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-30-2021 dateno.revisions 1 1ST PLAN CHECK 04.29.21 2 2ND PLAN CHECK 04.30.21 04/30/2021 SPA WD: -54" POOL 1'-0" TANNING SHELF WD: -7" WD: -15" WD: -42" 36'-6"1'-0"9'-0"1'-0" 48'-6"1"1'-0"21'-1"1'-0"1'-2"1'-2"1'-2"10'-8"1'-0"48'-4"23'-1"1'-0"13'-9"1'-0" 15'-9"21'-1"1'-0"1'-0"WD: -23" WD: -31" WD: -39" A2 SP-3-1 A2 SP-3-1 A1 SP-3-1 A1 SP-3-1 2 S-2 1 S-2 2 S-2 2 S-2 4 S-2J-02 CONTROLLER WATER FEATURE PANEL JANDY 6614AP-L 1"1"1"1"1"23'-6"1"22'-8"1"71'-5"WD: -58"WD: -54" WD: -22"32'-0"2 S-2 2 S-2 3 S-2 2'-0"1'-3"1'-6"2'-6"1"1" A3 SP-3-1 A3 SP-3-1 WD: -58" WD: -54" WD: -50" WD: -50" WD: -49" H-03 JANDYHEATER JXi400SPA J-01 CONTROLLER POOL/SPA PANEL JANDY 6614AP-L WD: -47" 1"1'-0"13'-3"1'-0"1'-6"1"1'-0"14'-10"1"1'-0"1'-2"1'-6"1'-0"1'-0"1'-0"20'-2"16'-11" 15'-10" 2 S-2 A SCALE: 1/4" = 1'-0" POOL PLAN SP-3.0 1/2"-1'-0"ENLARGED POOL PLANSHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE.LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-07-2021 dateno.revisions CBP04/30/2021 F. F. SPA F. F. POOL WATER LINE 2 S-2 4 S-2 GUNITE WALL1'-10"1'-8"1'-0"4'-6"7"8"8"8"8"8"3'-11"GUNITE SLAB POOL WATER LINE GUNITE SLAB 2 S-2 F. F. 3 S-2 F. F. SPA 1'-10"1'-8"1'-0"4'-6"GUNITE WALL TYP. POOL WATER LINE F. F. GUNITE SLAB 1 S-2 2 S-2 GUNITE WALL TYP. A1 SCALE: 1/4"=1'-0" POOL SECTION A2 SCALE: 1/4"=1'-0" POOL SECTION POOL SECTIONSSP-3.1 AS NOTED SHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE.LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-07-2021 dateno.revisions A3 SCALE: 1/4"=1'-0" POOL SECTION CBP 04/30/2021 3" PVC TO P-02 3" PVC TO P-01 3'-0" TYP.ALL MAIN DRAINS3" PVC TO P-04 3" PVC TO P-05 3" PVC TO P-06 2-1/2" PVC TO P-02 2-1/2" PVC TO P-01 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 24 W 3" PVC TO P-08 2-1/2" PVC TO P-03 3" PVC TO P-09 3" PVC TO P-07 R2 R2 R2 2-1/2" PVC FROM H-02 R1 R1 R1 R1 14'-4"3'-0"6'-0"2-1/2" PVC FROM H-01 R3 R3 2-1/2" PVC FROM H-03 R6 R6 R6 3" PVC TO P-06 R4 R4 R4 3" PVC FROM P-04 R5 R5 R5 3" PVC FROM P-05 6'-0"6'-0"6'-0"6'-0"9'-6" 1'-41 2"5'-6"5'-6"1'-41 2" 6'-0"6'-0"3'-0"6'-0"3'-0"6'-0"6'-0"6'-0"6'-0"6'-0"4'-11"4'-11" R3 R3 R4 R4 R4 R5 DBLLOWDBL 2-1/2" PVC FROM P-08 DBLLOWDBL 2-1/2" PVC FROM P-08 HI MID LOW LOW HI MID 2-1/2" PVC FROM P-07 B SCALE: 1/4" = 1'-0" PLUMBING PLAN SP-3.2 1/2"-1'-0"PLUMBING PLANSHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE.LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-07-2021 dateno.revisions B SCALE: 1/4" = 1'-0" SPA JET PLAN CBP 26'-0"1'-6"3'-0"20'-0"3'-0" WATER FEATURE WD: -30" C SP-4.0 C SP-4.0 8"1/4"x3"x9" STEEL BRACKET EVERY 12" TYP. LINE OF "VALANCE" TO HIDE RAIN CURTAIN 10"6"5'-11"9'-0"5'-11"6"1'-6" DEEPEN CONT. FTG AS REQUIRED TO ALIGN W/ BOT OF FTG (3 SACK SLURRY MIN BELOW FTG) PAVERS BY OTHERS F.F. 3" CLR #3 DOWEL @12" OC. W/STD HK 2'-8"2'-6"PORCELAIN TILE #3 DOWEL@12" OC. W/STD HK #3 HORIZ @12" O.C.1'-0"WATER LEVEL IN TROUGH WHEN WATER FEATURE IS OPERATING LED LIGHT BY OTHERS PORCELAIN STONE OREQ RAIN CURTAIN PORCELAIN STONE #3 BARS @12" OC. EA WAY #3 DOWEL @12" OC. W/ STD HK #3 BARS CONT. ROUGHEN SURFACE TYP. (E) HOUSE CONCRETE CONT. FOOTING 6" 3" CLR 2" CLRTYP.3"CLR3"CLR3"CLR6"6"6"6"EQ.EQ.6" #3 HORIZ @12" OC. #3 HORIZ @12" O.C. 3'-0" MIN. SEPARATION 3" PVC TO P- 1" ELECTRICAL CONDUIT TO J-015'-3"5'-3"5'-3"5'-3" 2-1/2" PVC FROM F- RR 3'-0" MIN. SEPARATION 3" PVC TO P-(4) 1-1/2" PVC FROM F- 1 4"334"114"314"1'-0"1/4"x3" WIDE STEEL BRACKET EVERY 12" FASTEN TO GUNITE 5" MASONRY BOLT (TOP&BOTTOM) 10" GUNITE WALL CUSTOM CASCADE RAIN FALL 90 20' LONG 114"41 2"4"112"3"3"1"2" 1-1/2" PVC PLUMBING LED STRIP LIGHTS CONTINUOUS BOTH SIDES HARDY BACKER PORCELAIN TILE 1/4"x STEEL PLATE ATTACHED SEPARATELY A SCALE: 1/2" = 1'-0" WATER FEATURE PLAN SP-4.0 1/2"-1'-0"ENLARGED WATERFEATURE PLANSHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE. LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-05-2021 dateno.revisions B SCALE: 1/2" = 1'-0" WATER FEATURE PLUMBING PLAN C SCALE: 1/2" = 1'-0" SECTION POOL LEGEND FLOOR DRAIN MAIN DRAIN SUCTION, 3FT MIN. SEPARATION UMBRELLA SLEVE FLUSH RETURN SKIMMER SMALL FRONT LOADING SKIMMER AUTO FILL DECK JET VACUUM PORT GAS METER SPA JET ELECTRICAL M "CMP" BRILLIANT WONDERS LED POOL BUBBLER CRYSTAL WATER JETS 20" DIA. AQUASTAR FLOOR DRAIN LED NICHELESS LIGHT UP NICHELESS LIGHT ELECTRICAL CONDUIT RETURN LINE SUCTION LINE PE GAS LINE MD U SJ R SK AF D VP G S ABBREVIATIONS W.S. WATER SURFACE W.D. WATER DEPTH F.F. FINISHED FLOOR F.S. FINISHED SURFACE F.G. FINISH GRADE ELEV. GRADE ELEVATION 2'-0" CBP 04/30/2021 30X36 CLR P 06 J 01 P 05 P 04 P 03 P 02 P 01 P 07 P 08 P 09 6"1'-3"6"1'-3"6"1'-3"6"1'-3"6"1'-3"6"1'-3"6"1'-3"6"1'-3"6"1'-3" 1 2 POOL EQUIPMENT SCHEDULE NO.TYPE LOCATION MFR MODEL NO. LIGHT SCHEDULE TYPE LOCATION MFR MODEL NO.QTY P-01 J-02 FILTER PUMP CONTROLLER POOL WATER FEATURE PANEL JANDY 6614AP-L JANDY JANDYF-01 FILTER JANDYH-01 HEATER JXi400 CV/CL 460 VSPHP270DV2A LED POOL JANDY JLU4C24W 20 LED SPA JANDY JLU4C24W 3 F-02 H-02 FILTER HEATER P-02 FILTER PUMP P-03 FILTER PUMP P-04 INFINITY PUMP P-05 P-06 P-07 P-08 P-09 P-10 P-11 H-03 F-03 F-04 F-05 LED ENTRY WATER FEATURE JANDY JLU4C24W 5 JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY CV/CL 460 CV/CL 460 CS100 CS100 FILTER FILTER FILTER HEATER JET PUMP JET PUMP JET PUMP FILTER PUMP WATER FEATURE PUMP VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A PHPF2.0 PHPF2.0 PHPF2.0 JXi400 JXi400 SPA POOL POOL POOL POOL SPA SPA SPA ENTRY WATER FEATURE ENTRY WATER FEATURE POOL SPA POOL ENTRY WATER FEATURE ENTRY WATER FEATURE INFINITY PUMP INFINITY PUMP POOL POOL SPA J-01 CONTROLLER POOL/SPA PANEL JANDY 6614AP-L 30X36 CLR30X36 CLR P 10 F 04 F 05 P 11 J 02 6"1'-3"6"1'-3"6"1'-3"6"1'-3"1 H 01 F 01 F 02 F 03 H 02 H 03 1 2 6"2'-6"1'-0"2'-0"6"2'-0"6"2'-0"1'-0"2'-0"6"2'-0" NOTE: FILTER AND HEATER TO BE LOCATED ON METAL RACK ABOVE FILTER PUMPS SP-5.0 1/2"-1'-0"EQUIPMENT LAYOUTSHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE.LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-30-2021 dateno.revisions 1 1ST PLAN CHECK 04.29.21 2 2ND PLAN CHECK 04.30.21 C SCALE: 1/2" = 1'-0" EQUIPMENT LAYOUT- LOWER LEVEL D SCALE: 1/2" = 1'-0" WATER FEATURE EQUIPMENT LAYOUT C SCALE: 1/2" = 1'-0" EQUIPMENT LAYOUT - UPPER LEVEL 04/30/2021 SOILS AND FOUNDATIONS 1. THE DESIGN OF THE FOUNDATION SYSTEM IS BASED UPON THE CRITERIA AND RECOMMENDATIONS CONTAINED IN THE FOLLOWING GEOTECHNICAL INVESTIGATION REPORT: A. "MADISON CLUB, TENTATIVE TRACT MAP 33076, NEC AVENUE 54 AND MADISON STREET, LA QUINTA, CALIFORNIA, GEOTECHNICAL INVESTIGATION" BY SLADDEN ENGINEERING (PROJECT No. 544-4810), DATED 01.28.05. B. "PROPOSED CUSTOM RESIDENCE, 53335 ROSS AVENUE, THE MADISON CLUB LOT 30A, LA QUINTA, CALIFORNIA" BY SLADDEN ENGINEERING (PROJECT No. 544-20168, DATED 05.28.20. 2. LOCATE AND PROTECT EXISTING UTILITIES TO REMAIN DURING AND/OR AFTER CONSTRUCTION. 3. REMOVE ABANDONED FOOTINGS, UTILITIES, ETC. WHICH INTERFERE WITH NEW CONSTRUCTION, UNLESS OTHERWISE INDICATED. 4. NOTIFY THE SEOR IF ANY BURIED STRUCTURES NOT INDICATED, SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC. ARE FOUND. 5. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, UNDERPINNING AND PROTECTION OF EXISTING CONSTRUCTION. 6. REMOVE LOOSE SOIL AND STANDING WATER FROM FOUNDATION EXCAVATIONS PRIOR TO PLACING CONCRETE. 7. BOTTOM OF FOOTINGS SHALL BE LEVEL. FOOTING ELEVATION CHANGES SHALL BE MADE USING FOOTING STEPS. 8. EXCAVATIONS FOR FOUNDATIONS MUST BE ACCEPTED BY THE GEOTECHNICAL ENGINEER OF RECORD (GEOR) PRIOR TO PLACING REINFORCING AND CONCRETE. NOTIFY THE GEOR WHEN EXCAVATIONS ARE READY FOR INSPECTION. 9. PLACE BACKFILL BEHIND RETAINING WALLS AFTER CONCRETE HAS ATTAINED FULL DESIGN STRENGTH. 10. MECHANICALLY COMPACT EXCAVATION BACKFILLS IN LAYERS. PROVIDE 90% MINIMUM COMPACTION IN ACCORDANCE WITH THE ASTM D1557 TEST METHOD AND THE GEOTECHNICAL REPORT. 11. SCARIFY AND RECOMPACT TOP 6 INCHES OF SOIL BENEATH FILL PER ITEM ABOVE. 12. PROVIDE POSITIVE SLOPES, BOTH DURING AND AFTER CONSTRUCTION, TO DIRECT SURFACE AND ROOF RUNOFF A MINIMUM OF 10'-0” FROM BUILDING FOUNDATIONS. REINFORCING STEEL 1. REINFORCING SHALL BE FABRICATED ACCORDING TO THE “MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION” AND SHALL CONFORM TO ASTM A615, GRADE 60. 2. PROVIDE REINFORCING SHOWN OR NOTED CONTINUOUS IN LENGTHS AS LONG AS PRACTICABLE. 3. TERMINATE REINFORCING STEEL IN STANDARD HOOKS UNLESS OTHERWISE SHOWN. 4. ALL REINFORCING STEEL INTERRUPTED BY STRUCTURAL STEEL SHALL TERMINATE WITHIN 1" OF STEEL SURFACE WITH A 90° STANDARD HOOK UNLESS OTHERWISE NOTED. 5. PROVIDE REINFORCING BAR DOWELS IN FOOTINGS, PILE CAPS AND OTHER SUPPORTING MEMBERS OF THE SAME SIZE AND SPACING AS VERTICAL REINFORCING UNLESS OTHERWISE NOTED. LAP SPLICE AS INDICATED ON TYPICAL DETAILS. 6. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE BEFORE CONCRETE IS PLACED. 7. ACCURATELY POSITION, SUPPORT AND SECURE REINFORCEMENT FROM DISPLACING DUE TO FORMWORK, CONSTRUCTION, OR CONCRETE PLACEMENT OPERATIONS. LOCATE AND SUPPORT REINFORCING BY METAL CHAIRS, RUNNERS, BOLSTERS, SPACERS AND HANGERS AT A MAXIMUM SPACING OF 3'-0”. 8. FIELD BENDING OF REINFORCING STEEL EMBEDDED IN CONCRETE SHALL NOT BE ALLOWED UNLESS APPROVED BY THE SEOR. 9. MILL CERTIFICATIONS SHALL BE SUBMITTED FOR REVIEW. GENERAL 1. MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2019 EDITION OF THE CALIFORNIA BUILDING CODE, TITLE 24, THE ORDINANCES OF THE LOCAL BUILDING OFFICIAL, AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 2. REFERENCE TO CODES, RULES REGULATIONS, STANDARDS, MANUFACTURER'S INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. 3. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, USE SIMILAR DETAILS OF CONSTRUCTION, SUBJECT TO REVIEW BY THE STRUCTURAL ENGINEER OF RECORD (SEOR). 4. DETAILS ON SHEETS TITLED “TYPICAL DETAILS” APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OF SIMILAR TO THOSE SPECIFICALLY REFERENCED. SUCH DETAILS ARE NOT NOTED AT EACH LOCATION THAT THEY OCCUR. 5. SEE POOL DRAWINGS (SP SHEETS) FOR ADDITIONAL INFORMATION. 6. VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK. NOTIFY SEOR OF DISCREPANCIES. 7. DO NOT SCALE THE DRAWINGS. 8. TOLERANCES SHALL BE ACCORDING TO THE BUILDING CODE. 9. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES. NOTIFY THE SEOR OF ANY DISCREPANCIES AND RESOLVE BEFORE PROCEEDING WITH THE WORK. 10. PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES INCLUDE, BUT MAY NOT BE LIMITED TO, BRACING AND SHORING FOR LOADS DURING CONSTRUCTION. RETAIN A REGISTERED CIVIL ENGINEER WHOM IS PROPERLY QUALIFIED TO DESIGN BRACING, SHORING, ETC. VISITS TO THE SITE BY THE OWNER'S REPRESENTATIVE WILL NOT INCLUDE OBSERVATION OF THE ABOVE NOTED ITEMS. 11. THE CONTRACTOR SHALL SUPERVISE, DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. THE SUPPORTING SERVICES BY THE SEOR, WHETHER PERFORMED PRIOR TO, DURING, OR AFTER CONSTRUCTION, ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DRAWINGS; BUT THEY DO NOT GUARANTEE THE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. 12. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING A SAFE PLACE TO WORK AND MEETING THE REQUIREMENTS OF ALL APPLICABLE JURISDICTIONS. EXECUTE WORK TO ENSURE THE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST DAMAGE BY FALLING DEBRIS AND OTHER HAZARDS RELATED WITH THIS WORK. STATEMENT OF SPECIAL INSPECTIONS (& STRUCTURAL TESTS) 1. STRUCTURAL TESTS AND INSPECTIONS SHALL BE ACCORDING TO 2019 CALIFORNIA BUILDING CODE. 2. THE SPECIAL INSPECTIONS IDENTIFIED ARE IN ADDITION TO THOSE REQUIRED BY SECTION 110 OF THE CODE, AS AMENDED. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY THE GOVERNING JURISDICTION. 3. AN INDEPENDENT TESTING AGENCY AND SPECIAL INSPECTORS WILL BE RETAINED BY THE OWNER (NOT THE CONTRACTOR OR ANY OTHER PERSON RESPONSIBLE FOR THE WORK) TO PERFORM TESTS AND SPECIAL INSPECTIONS. THE CONTRACTOR SHALL PROVIDE ACCESS AND FURNISH SAMPLES TO THE AGENCY AS REQUIRED. 4. IF INITIAL TESTS OR INSPECTIONS MADE BY THE OWNER'S TESTING AGENCY REVEAL THAT ANY PORTION OF THE WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, ADDITIONAL TESTS, INSPECTIONS AND NECESSARY REPAIRS WILL BE MADE AT THE CONTRACTOR'S EXPENSE. 5. A CERTIFICATE OF SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION MUST BE COMPLETED AND SUBMITTED TO THE GOVERNING JURISDICTION AND SEOR. 6. PERIODIC OR CONTINUOUS PRESENCE AND INSPECTION BY THE PROJECT OR SPECIAL INSPECTOR ARE REQUIRED FOR THE FOLLOWING TYPES OF WORK WHERE OCCURS: REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION (CBC TABLE 1705.3) TYPE INSPECTION FREQUENCY REFERENCED STANDARD IBC REFERENCE 1.INSPECT REINFORCEMENT AND VERIFY PLACEMENT.PERIODIC ACI 318 CH 20, 25.2, 25.3, 26.6.1-26.6.3 1908.4 3.INSPECT ANCHORS CAST IN CONCRETE PERIODIC ACI 318: 17.8.2 --- 5. VERIFY USE OF REQUIRED DESIGN MIX.PERIODIC ACI 318: CH. 19, 26.4.3, 26.4.4 1904.1, 1904.2, 1908.2, 1908.3 6. PRIOR TO GUNITE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE GUNITE. CONTINUOUS ASTM C172 ASTM C31 ACI 318: 26.5, 26.12 1908.10 7.INSPECT GUNITE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.CONTINUOUS ACI 318: 26.5 1908.6, 1908.7, 1908.8 8.VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.PERIODIC ACI 318: 26.5.3-26.5.5 1908.9 12.INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.PERIODIC ACI 318: 26.11.1.2(b) --- STRUCTURAL OBSERVATION -NOT REQUIRED ABBREVIATIONS AB ANCHOR BOLT ABV ABOVE ADDL ADDITIONAL AFF ABOVE FINISH FLOOR ALT ALTERNATE BLDG BUILDING BLKG BLOCKING BM BEAM BN BOUNDARY NAIL BOF BOTTOM OF FOOTING BOT BOTTOM BRG BEARING BSMT BASEMENT BTWN BETWEEN C CHANNEL, CAMBER CANT CANTILEVER(ED) CIP CAST-IN-PLACE CJ CONTROL JOINT, CLG JOIST CJP COMPLETE JOINT PENETRATION CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CTSK COUNTERSINK CTR CENTER(ED) DBL DOUBLE DEMO DEMOLISH, DEMOLITION DET DETAIL DF DOUGLAS FIR DIA, Φ DIAMETER DIAG DIAGONAL DIAPH DIAPHRAGM DIM DIMENSION DIST DISTANCE DN DOWN DO DITTO (REPEAT) DWG(S) DRAWING(S) (E), EXIST EXISTING EA EACH E.A. EXPANSION ANCHOR EF EACH FACE EJ EXPANSION JOINT EA EACH ELEV ELEVATOR, ELEVATION EMB(ED)EMBEDMENT EN EDGE NAIL EQ EQUAL ES EACH SIDE,EDGE SCREW EW EACH WAY EXT EXTERIOR FDN FOUNDATION FF FINISHED FLOOR FJ FLOOR JOIST FLR FLOOR FN FIELD NAIL FO FACE OF FOC FACE OF CONCRETE FOM FACE OF MASONRY FOS FACE OF STUD FOW FACE OF WALL FS FAR SIDE, FIELD SCREW FTG FOOTING GA, ga GAGE, GAUGE GALV GALVANIZED GLB GLU-LAM BEAM GYP BD GYPSUM BOARD HD HOLDOWN HDR HEADER HDG HOT DIPPED GALVANIZED HGR HANGER HORIZ, (H) HORIZONTAL HP HIGH POINT HSB HIGH STRENGTH BOLT HSS HOLLOW STRUCTURAL STEEL HT HEIGHT K KIPS, 1000# KP KING POST L ANGLE LB(S), #POUND Ld DEVELOPMENT LENGTH Ldh HOOKED DEVELOPMENT LENGTH LLBB LONG LEG BACK-TO-BACK LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LONG LONGITUDINAL LP LOW POINT Ls LAP SPLICE LENGTH LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER LWC LIGHTWEIGHT CONCRETE MB MACHINE BOLT MEP MECH, ELEC & PLUMBING MFR MANUFACTURER MTL METAL (N) NEW NF NEAR FACE NIC NOT IN CONTACT NO, # NUMBER NS NEAR SIDE NSG NON SHRINK GROUT NTS NOT TO SCALE NWC NORMALWEIGHT CONCRETE oc ON CENTER OH OPPOSITE HAND OPNG OPENING OWSJ OPEN WEB STEEL JOIST PAF POWER ACTUATED FASTENER PERP PERPENDICULAR PJP PARTIAL JOINT PENETRATION PL PLATE PP PER PLAN PSF POUNDS/ SQUARE FOOT PSI POUNDS/ SQUARE INCH PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED R, RAD RADIUS REINF REINFORCEMENT REQD REQUIRED RJ ROOF JOIST RO ROUGH OPENING RR ROOF RAFTER S.A.D. SEE ARCH DOCUMENTS SC SLIP-CRITICAL SCHED SCHEDULE SECT SECTION S.E.D. SEE ELEC DOCUMENTS SEOR STRUCTURAL ENGINEER OF RECORD SHT SHEET SHTG SHEATHING SIM SIMILAR SL SLOPE S.M.D. SEE MECH DOCUMENTS SMS SHEET METAL SCREW S.O.G. SLAB ON GRADE SPEC SPECIFICATION(S) SQ SQUARE SS STAINLESS STEEL ST SNUG-TIGHTENED STAG STAGGER(ED) STD STANDARD STL STEEL STRUC STRUCTURAL SUSP SUSPENDED SW SHEAR WALL T&B TOP AND BOTTOM T&G TONGUE AND GROOVE THK THICK(NESS) THD THREADED TN TOE NAIL TO TOP OF TOC TOP OF CONCRETE TOF TOP OF FOOTING TOFR TOP OF FRAMING TOS TOP OF STEEL TOW TOP OF WALL TRANS TRANSVERSE TS TOP OF SHEATHING TSG TAPERED STEEL GIRDER TYP TYPICAL UON UNLESS OTHERWISE NOTED VERT,(V) VERTICAL VIF VERIFY IN FIELD W WIDE FLANGE w/ WITH w/o WITHOUT WHS WELDED HEADED STUD WP WORK POINT WT WEIGHT WTS WELDED THREADED STUD WWF WELDED WIRE MESH XS EXTRA STRONG XXS DOUBLE EXTRA STRONG ATR ALL-THREAD ROD S.C.D. SEE CIVIL DOCUMENTS S.P.D. SEE PLUMB DOCUMENTS R/R REMOVE & REPLACE WS WOOD SCREW A.A. ADHESIVE ANCHOR A.D. ADHESIVE DOWEL PCF POUNDS/ CUBIC FEET RS ROUGH SAWN LOC LOCATION JT JOINT BLW BELOW FG FINISHED GRADE TOT TOTAL LO LOW ADJ ADJACENT HI HIGH MDL MODEL DESIGN CRITERIA 1. THE OBJECTIVE OF THIS WORK IS TO DESIGN A POOL AND SPA FOR THE RESIDENTIAL PROPERTY. SCOPE ALSO INCLUDES A STAND-ALONE WATER FEATURE. 2. DESIGN LOAD CRITERIA: A. ALLOWABLE COEFFICIENT OF FRICTION: 0.48 B. ALLOWABLE SLIDING RESISTANCE: 130 PSF (50% OF WEIGHT MAXIMUM) C. ALLOWABLE PASSIVE PRESSURE: 300 PCF D. FRICTION AND PASSIVE PRESSURE MAY BE COMBINED IN CALCULATION OF TOTAL RESISTANCE TO SLIDING (WITH A 33% REDUCTION IN FRICTION RESISTANCE). E. A ONE-THIRD INCREASE IS APPLICABLE TO SOIL CAPACITIES FOR SHORT-TERM LOADING (WIND/SEISMIC). F. SOIL RETAINING STRUCTURES: 3. FOUNDATIONS (BASED ON GEOTECHNICAL REPORT): GRAVITY LOADS ACTUAL STRUCTURE & OPERATING EQUIPMENT WEIGHTSDEAD LOADS ULTIMATE WIND LOADS EXPOSURE CATEGORY C II (T.1604.5)RISK CATEGORY DESIGN WIND SPEED, VULT,VASD 110 MPH PER ATC TOOL, 85 PER EQN 16-33 IMPORTANCE FACTOR, IP 1.0 (RISK CATEGORY II, T.1604.5) ULTIMATE SEISMIC LOADS (COMPONENTS) MAPPED SPECTRAL ACCELERATIONS SS = 1.50g,S1 = 0.61g (PER GEOTECHNICAL REPORT) SITE CLASS D (PER GEOTECHNICAL REPORT) DESIGN SPECTRAL RESPONSE COEFFICIENTS SDS = 1.00g, SD1 = NULL SEISMIC DESIGN CATEGORY D FOOTING TYPE ALLOWABLE NET PRESSURE, D+L (PSF) MIN WxH* (IN) INCREASE WITH WIDTH, D+L (PSF/FT) INCREASE WITH DEPTH, D+L (PSF/FT) MAX ALLOWABLE NET PRESSURE, D+L (PSF) CONTINUOUS 1,500 12x12 300 600 3,000 ISOLATED PAD 2,000 24x12 300 600 3,000 LATERAL PRESSURE & SLIDING RESISTANCE LEVEL GRANULAR BACKFILL (PCF) 2:1 GRANULAR BACKFILL (PCF) ACTIVE PRESSURE (PER GEOTECHNICAL REPORT)35 AT-REST (RESTRAINED WALLS) PRESSURE (PER GEOTECHNICAL REPORT)55 *H= MIN EMBEDMENT BELOW LOWEST ADJACENT GRADE. FORMWORK 1. PROVIDE CURING WHERE FORMS ARE REMOVED IN LESS THAN 7 DAYS. 2. REMOVE FORMS NO SOONER THAN 48 HOURS AFTER PLACING CONCRETE. GUNITE 1. WHERE NOT SPECIFIED, GUNITE MAY BE USED AS AN ALTERNATIVE TO CAST-IN-PLACE CONCRETE. A. GUNITE SHALL CONFORM TO THE REQUIREMENTS OF THE 2019 CBC SECTION 1913 AND CHAPTER 19 IN GENERAL FOR REINFORCED CONCRETE AND PROVISIONS OF ACI 1506. 2. GUNITE SHALL HAVE THE SAME COMPRESSIVE STRENGTH (f'c) AND ALL OTHER REQUIREMENTS AS CAST-IN-PLACE CONCRETE UNLESS OTHERWISE NOTED. 3. THE NOMINAL MAXIMUM SIZE OF COARSE AGGREGATES SHALL BE ¾" UNLESS OTHERWISE NOTED. A. WHEN #5 OR SMALLER BARS ARE USED, THERE SHALL BE A MINIMUM CLEARANCE BETWEEN PARALLEL REINFORCEMENT BARS OF 2½ INCHES. 4. LAP SPLICES IN REINFORCING BARS SHALL BE BY THE NON-CONTACT LAP SPLICE METHOD WITH AT LEAST 2 INCHES CLEARANCE BETWEEN BARS. 5. CONCRETE TO RECEIVE GUNITE SHALL HAVE THE ENTIRE SURFACE THOROUGHLY CLEANED AND ROUGHENED BY SAND BLASTING, AND JUST PRIOR TO RECEIVING GUNITE, SHALL BE THOROUGHLY CLEANED OF ALL DEBRIS, DIRT AND DUST. CONCRETE SHALL BE WETTED BEFORE GUNITE IS DEPOSITED, BUT NOT SO WET AS TO OVERCOME SUCTION. SAND FOR SAND BLASTING SHALL BE CLEAN, SHARP AND UNIFORM IN SIZE, WITH NO PARTICLES THAT WILL PASS A 50-MESH SCREEN. 6. CURING SHALL BE IN ACCORDANCE WITH SECTION 1913.9. CURING COMPOUND USED ON GUNITE SHALL BE APPROVED BY THE SEOR. 7. STRENGTH TESTS FOR GUNITE SHALL BE MADE IN ACCORDANCE WITH ASTM STANDARDS BY AN APPROVED AGENCY ON SPECIMENS THAT ARE REPRESENTATIVE OF THE WORK AND WHICH HAVE BEEN WATER SOAKED FOR AT LEAST 24 HOURS PRIOR TO TESTING. THE MAXIMUM-SIZE AGGREGATE SHALL BE 3/8 INCH AND SPECIMENS SHALL CONSIST OF NOT LESS THAN 2-INCH-DIAMETER CORES OR 2-INCH CUBES. 8. SAMPLING FOR GUNITE SPECIMENS SHALL BE TAKEN FROM THE IN-PLACE-WORK AND SHALL BE TAKEN AT LEAST ONCE EACH SHIFT, BUT NOT LESS THAN ONE FOR EACH 50 CUBIC YARDS OF GUNITE. CAST-IN-PLACE CONCRETE 1. CONCRETE IS MILDLY REINFORCED AND CAST-IN-PLACE. WHERE REINFORCING IS NOT SPECIFICALLY SHOWN OR WHERE DETAILS ARE NOT GIVEN, PROVIDE REINFORCING SIMILAR TO THAT SHOWN FOR SIMILAR CONDITIONS, SUBJECT TO REVIEW BY THE SEOR. 2. DIMENSIONS SHOWN FOR LOCATION OF REINFORCING ARE TO THE FACE OF BARS AND DENOTE CLEAR COVERAGE UNLESS OTHERWISE NOTED. 3. THE MINIMUM CONCRETE CLEAR COVER TO REINFORCING BARS IS AS FOLLOWS: a. COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS. FORMED SURFACES EXPOSED TO WEATHER OR IN CONTACT WITH EARTH: #5 BARS AND SMALLER 1½ #6 BARS AND LARGER 2 USE f'c (PSI) (a) MAX SLUMP (IN) NOMINAL MAX AGGREGATE (IN) WATER CEMENTITIOUS RATIO (MAX) TYPICAL 3,000 4 1 0.50 LOCATIONS CLEAR COVER, INCHES CONCRETE PLACED AGAINST EARTH 3 SLABS ON GRADE (TOP CLEARANCE)1½ 4. CONCRETE TYPES 5. CONCRETE MIXES SHALL BE DESIGNED BY A QUALIFIED TESTING LABORATORY, BEARING A CALIFORNIA REGISTERED CIVIL ENGINEER'S STAMP, AND APPROVED BY THE SEOR PRIOR TO USE. 6. PORTLAND CEMENT SHALL BE TYPE II OR V CONFORMING TO ASTM C150 UNLESS OTHERWISE NOTED. 7. COARSE AGGREGATE SHALL CONFORM TO ASTM C-33. 8. ALL CONCRETE SHALL BE NORMAL WEIGHT (145 PCF) HARD ROCK TYPE. 9. CONTINUOUSLY MOIST CURE CONCRETE FOR 7 DAYS MINIMUM. WATER FOG SPRAYS, PONDING, SATURATED ABSORPTIVE COVERS OR MOISTURE RETAINING COVERS MAY BE USED. IN LIEU OF MOIST CURING, CURING COMPOUNDS MAY BE SUBMITTED TO THE ARCHITECT FOR ACCEPTANCE. 10. PIPES AND CONDUIT ARE TO BE PLACED IN THE MIDDLE THIRD OF SLABS AND WALLS. MAXIMUM DIAMETER SHALL BE ONE-THIRD OF SLAB OR WALL THICKNESS AND MINIMUM SPACING SHALL BE 3 DIAMETERS FROM CENTER TO CENTER. 11. ROUGHEN CONCRETE SURFACES OF CONSTRUCTION JOINTS TO ¼” AMPLITUDE AND CLEAN OF LAITANCE, FOREIGN MATTER AND LOOSE PARTICLES. LOCATE CONSTRUCTION JOINTS AS SHOWN ON THE DRAWINGS. SUBMIT ALTERNATE JOINT LOCATIONS OR JOINTS NOT SHOWN TO THE SEOR FOR REVIEW AND APPROVAL PRIOR TO PROCEEDING WITH THE WORK. 12. AT LOCATIONS WHERE CONCRETE IS CAST AGAINST EXISTING CONCRETE, ROUGHEN CONTACT SURFACES TO ¼” AMPLITUDE AND CLEAN OF LAITANCE, FOREIGN MATTER AND LOOSE PARTICLES. 13. CONSOLIDATE CONCRETE PLACED IN FORMS BY MECHANICAL VIBRATING EQUIPMENT SUPPLEMENTED BY HAND- SPADING, RODDING OR TAMPING. USE EQUIPMENT & PROCEDURES FOR CONSOLIDATION OF CONCRETE IN ACCORDANCE WITH THE RECOMMENDED PRACTICES OF ACI 309 TO SUIT THE TYPE OF CONCRETE & PROJECT CONDITIONS. 14. NO WOOD SPREADERS ALLOWED. NO WOOD STAKES ALLOWED IN AREAS TO BE CONCRETED. NOTES: 1. ALL DETAILING OF REINF SHALL COMPLY WITH THIS SCHEDULE UNLESS SPECIFICALLY DETAILED OTHERWISE. 2. REINF DEVELOPMENT LENGTH AND SPLICE TABLE IS BASED ON UNCOATED GRADE 60 STEEL PER ACI 318 CHAPTER 25 AND SECTION 18.8.5. 3. db = BAR DIAMETER. 4.NP = NOT PERMITTED. 5. TOP REINF IS HORIZONTAL REINF THAT HAS MORE THAN 12" OF CONCRETE PLACED BELOW IT. 6. LAP LENGTHS SHOWN MEET REQUIREMENTS FOR CLASS "B" SPLICE. 7. CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED SHALL NOT BE LESS THAN THE LARGER OF 2 BAR DIAMETERS OR 2". CLEAR COVER SHALL NOT BE LESS THAN THE LARGER OF THE BAR DIAMETER SIZE OR PER GENERAL NOTES. 8. A STANDARD HOOK SHALL BE PROVIDED WHERE THE DEVELOPMENT LENGTH IS NOT POSSIBLE DUE TO SPACE RESTRICTIONS (REFER TO HOOKED BAR SCHEDULE). 9. SMALLER BAR LAP LENGTH MAY BE USED WHEN SPLICING BARS OF DIFFERING DIAMETERS. 10. AT CONC WALLS, SPLICES IN HORIZONTAL REINF SHALL BE STAGGERED. 11. Ld = DEVELOPMENT LENGTH (DEV), Lst = LAP SPLICE (LAP). 2" MIN SPLICE BAR MAIN BAR f'c (PSI) HOOKED BAR DEVELOPMENT LENGTH, Ldh (INCHES) REINFORCEMENT DEVELOPMENT & LAP LENGTHS (INCHES) BASE MATERIAL NWC f'c (PSI)CONDITION REINFORCEMENT SIZE 3,000 STD DEV TOP DEV STD LAP TOP LAP #3 #4 #5 #6 17 22 28 33 23 29 37 43 23 29 37 43 29 38 48 56 #3 9 #4 11 #5 14 #6 17 REINFORCEMENT SIZE 3,000 Ld Lst Ldh 2db NOTE: d = BAR DIAMETER BAR OFFSET 1 6 MIN BAR END HOOKS & BENDSDDD 2½" MIN 4d OR 12dD = 6d FOR #3 TO #8 D = 8d FOR #9 TO #11 D = 10d FOR #14 & #18 END HOOKS, ALL GRADES BAR SIZE D J #3 2¼" 3" 4" 5" 6"4½" 3¾" 3"#4 #5 #6 dNOTE: d = BAR DIAMETER D D 3" MIN 6d OR STIRRUP / TIE HOOKS & BENDS 3" MIN 6dD = 1½" FOR #3 D = 2" FOR #4 D = 2½" FOR #5 J2'-6" TYP RECESS WALL PP2- #5 VERT TYP SECTION AT WALL RECESS VERT REINF PP HORIZ REINF PP TYP ADD HORIZ REINF TO MATCH SIZE & SPACING OF HORIZ WALL REINF END OF WALL DOUBLE REINFPPLAP HORIZ WALL REINF PP 2- #5 MIN 2- #5 MIN END OF WALL SINGLE REINFPPWALL REINF PP STD HOOK ALT BEND PP WALL REINF PP TYP PPHORIZ LAP WALL INTERSECTION DOUBLE REINF 2- #5 CONT PP PPHORIZ LAP WALL REINF PP TYP ALT BEND 2- #5 VERT WALL INTERSECTION SINGLE REINF PP PPWALL REINF PP TYP HORIZ LAPSTD HOOK STD HOOK CORNER DOUBLE REINF CORNER SINGLE REINF PPPP HORIZ LAPWALL REINF PP TYP 2- #5 VERT SCALE: NONE GENERAL NOTES 7 SCALE: NONE TYPICAL DEVELOPMENT & LAP LENGTHS 2 SCALE: NONE TYPICAL REINFORCEMENT BEND DETAILS 3 SCALE: NONE TYPICAL CONCRETE WALL DETAILS 1 w w w . s p i r e s t r u c t u r e s . c o m26461 Rancho Parkway South Lake Forest, CA 92630tel:949.916.3440 Copyright Spire Structural Engineering Inc.43653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 820132SHEET: DATE: SCALE: DWN BY: dateno.revisions N.T.S. 02/09/21 4:45:27 PM ENG: JCWJOB#: 21SPR002GENERAL NOTES& TYPICALDETAILSS1 MRP81-560 BAFFIN AVE.LA QUINTA, CA.05/18/18LOT 100B04/30/2021 4" CONCRETE S.O.G. NATURAL GRADE 6"WATER LINE STONE / TILE CAP 1'-0"1'-8" GUNITE WALL1"3'-7"6" 6" APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH6"4" 10" MECHANICALLY COMPACT DISTURBED SOIL IN LAYERS TO A 90% MIN COMPACTION IN ACCORDANCE TO ASTM D1557 TEST METHOD 6"3"CLR3" CLR 2" 2"2"DEV PER2/S1 TYP1 1 PEBBLE SHEEN FINISH T.B.D. #3 HORIZ @ 12"O.C EA FACE #3 DOWEL W/STD HOOK @12"O.C EA FACE (2)-#3 CONT 3" CLRROUGHEN SURFACE #3 DOWEL W/STD HOOK @12"O.C DEPTH≤ 4'-6:#3 DOWEL W/STD HOOK @12"O.C DEPTH> 4'-6: ADD #3 DOWEL W/STD HOOK @6"O.C #3 @12"O.C EA WAY #3 @12"O.C EA WAY #3 HORIZ @12"O.C 6" FOR DEPTH≤4'-6" & 8" FOR DEPTH>4'-6" (6'-0" MAX. DEPTH)10"6"1'-4" #3 HORIZ @12"O.C 2-#3 CONT.3"CLR1'-4" 2'-0" 2-#3 CONT.6"STONE / TILE TO TROUGH FLOOR 1" FIBERGLASS GRATE F. F. GUNITE WALL STONE / TILE COPING MITER ALL CORNERS 4" CONCRETE S.O.G. APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH PEBBLE SHEEN FINISH T.B.D. MECHANICALLY COMPACT DISTURBED SOIL IN LAYERS TO A 90% MIN COMPACTION IN ACCORDANCE TO ASTM D1557 TEST METHOD #3@ 12" O.C. EA WAY WATERPROOF NON-POROUS SLIPSHEET WATER LINE 10" 6" 1" 1'-0" 8" 3"3"1'-2"1'-2"1'-2"2"3"7"8"8"8"8"6"TILE & SETTING BED 3'-11"PER PLAN 1'-2"2"2" #3 CONT #3 DOWEL W/STD HOOK @12" O.C. #3@ 12" O.C. EA WAY6"#3@ 12" O.C. EA WAY LAP PER 2/S1 #3 DOWEL W/STD HOOK @12" O.C. EA FACE 6"8"1'-2" WATER LINE 1"5"FINISH FLOOR COMPACTED SUBGRADE 6"8"6" TILE & SETTING BED 4" CONCRETE S.O.G. 6" WATER LINE TILE PEBBLE SHEEN FINISH T.B.D. GUNITE WALL PER PLAN 1"5"APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH 10" 1'-0" STONE / TILE COPING MITER ALL CORNERS 4" WATERPROOF NON-POROUS SLIPSHEET 3" CLR 2" 2" CLR 2"CLR3"3" CLR #3 CONT.8"#3 DOWEL W/STD HOOK @12" O.C. #3 DOWEL W/STD HOOK @12" O.C. #3 HORIZ @12" O.C. EA FACE 6"WATER LINE 1"5"FINISH FLOOR COMPACTED SUBGRADE 6"8" 6" TILE & SETTING BED 4" CONCRETE S.O.G. 6" WATER LINE TILE PEBBLE SHEEN FINISH T.B.D. GUNITE WALL 1"5"APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH 10" 1'-0" STONE / TILE COPING MITER ALL CORNERS 4" WATERPROOF NON-POROUS SLIPSHEET 3" CLR 2" 2" CLR 2"CLR3"3" CLR #3 CONT.8"#3 DOWEL W/STD HOOK @12" O.C. #3 DOWEL W/STD HOOK @12" O.C. #3 HORIZ @12" O.C. EA FACE 1 1 6"1'-0"PER PLAN PER PLAN 6"6" 3" CLR 3"3"#3 @12" O.C. EA WAY #3 HORIZ@12" O.C. #3 DOWEL W/STD HOOK@12" O.C. #3 HORIZ @12" O.C.6"1'-4" 2-#3 CONT. #3 @12" O.C. EA WAY6"#3 DOWEL W/STD HOOK@12" O.C. #3@12" O.C. EA WAY DETAILSS-2 AS NOTED 1 SCALE: 1"=1'-0" INFINITY WALL DETAIL 2 SCALE: 1"=1'-0" POOL EDGE DETAIL 4 SCALE: 1"=1'-0" POOL STEPS DETAIL 3 SCALE: 1"=1'-0" SPA EDGE DETAIL SHEET: DATE: SCALE: DWN BY: LOT 100B81-560 BAFFIN AVE.LA QUINTA, CA.43653 Parkway EsplanadeLa Quinta, CA 92253760 - 772 - 1111 Stokerpools.com Lic# 820132ZB 04-05-2021 dateno.revisions 04/30/2021