BPOL2022-0246ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT F P D SERVICES INC DBA STOKER
POOLS
77-799 Jackal Drive,
Ste. B
Palm Desert CA 92211 (760)393-5286 ACCOUNTING@STOKE
RPOOLS.COM
CONTRACTOR F P D SERVICES INC DBA STOKER
POOLS
77-799 Jackal Drive,
Ste. B
Palm Desert CA 92211 (760)393-5286 ACCOUNTING@STOKE
RPOOLS.COM
OWNER DISCOVERY BUILDERS 80955 Avenue 52 LA QUINTA CA 92253 (760)393-5286 tjenkins@discoverybuil
dersllc.com
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
E-MAIL JULIO ANAYA 7/1/2022 7/1/2022 INFORMED APPLICANT PERMIT IS APPROVED AND READY
FOR ISSUANCE
CONDITIONS
Description: DISCOVERY LLC / POOL,SPA AND [2] WATER FEATURES AT REAR YARD
Type: POOL CONSTRUCTION
(WEB)
Subtype: PRIVATE Status: FINALED Applied: 6/13/2022 ECON
Parcel No: 767680016 Site Address: 53060 ROSS AVE LA QUINTA,CA 92253 Approved: 7/1/2022 JAN
Subdivision: TR 33076-1 Block: Lot: 54 Issued: 7/1/2022 ONLINE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/11/2023 JAN
Valuation: $250,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: DISCOVERY LLC / POOL,SPA AND [2] WATER FEATURES AT REAR AND FRONT YARDS. TWO DROWNING SAFETY FEATURES AND
BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET
ON SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR
YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE.
FINANCIAL INFORMATION
Printed: Tuesday, October 24, 2023 8:41:31 AM 1 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0246
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
BSAS SB1473 FEE 101-0000-20306 0 $10.00 $10.00 7/1/22 WEB12409 637944942
41 CREDIT 820132 ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $10.00 $10.00
DETACHED SPA/WATER
FEATURE/OTHER 101-0000-42404 0 $416.82 $416.82 7/1/22 WEB12409 637944942
41 CREDIT 820132 ECON
SWIMMING
POOL/SPA/WATER
FEATURE
101-0000-42404 0 $208.41 $208.41 7/1/22 WEB12409 637944942
41 CREDIT 820132 ECON
SWIMMING
POOL/SPA/WATER
FEATURE PC
101-0000-42600 0 $113.38 $113.38 7/1/22 WEB12409 637944942
41 CREDIT 820132 ECON
Total Paid for POOL / SPA 2021: $738.61 $738.61
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/1/22 WEB12409 637944942
41 CREDIT 820132 ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/1/22 WEB12409 637944942
41 CREDIT 820132 ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$764.61 $764.61
Printed: Tuesday, October 24, 2023 8:41:31 AM 2 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0246
UNDERGROUND PLBG DCL 8/4/2022 8/4/2022 NOT READY eTRAKiT Inspection
Request
8/3/2022 2:08 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
- WORK INCOMPLETE
UNDERGROUND ELEC DCL 8/4/2022 8/4/2022 NOT READY eTRAKiT Inspection
Request
8/3/2022 2:08 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
- WORK INCOMPLETE.
PRE-GUNITE DCL 8/4/2022 8/4/2022 NOT READY eTRAKiT Inspection
Request
8/3/2022 2:08 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
- WORK INCOMPLETE.
Printed: Tuesday, October 24, 2023 8:41:31 AM 3 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0246
UNDERGROUND PLBG JAN 8/5/2022 8/5/2022 APPROVED eTRAKiT Inspection
Request
8/4/2022 2:58 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
UNDERGROUND ELEC JAN 8/5/2022 8/5/2022 APPROVED eTRAKiT Inspection
Request
8/4/2022 2:58 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
PRE-GUNITE JAN 8/5/2022 8/5/2022 APPROVED eTRAKiT Inspection
Request
8/4/2022 2:58 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
UNDERGROUND GAS DCL 8/31/2022 8/31/2022 APPROVED eTRAKiT Inspection
Request
8/30/2022 9:26 AM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: CRAIG@STOKERPOOLS.COM
Printed: Tuesday, October 24, 2023 8:41:31 AM 4 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0246
DECK BOND JFU 9/9/2022 9/9/2022 APPROVED eTRAKiT Inspection
Request
9/8/2022 9:18 AM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
PRE-PLASTER BLAK 1/27/2023 1/27/2023 APPROVED eTRAKiT Inspection
Request
1/26/2023 8:47 AM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
FINAL**JFU 5/5/2023 5/5/2023 DISAPPROVE
D
eTRAKiT Inspection
Request
5/4/2023 1:55 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
-PROVIDE THERMAL POOL COVER ON SITE-
THE FLOATING BUOY ALARMS STATE THEY
ARE FOR USE IN ABOVE GROUND POOLS
ONLY
Printed: Tuesday, October 24, 2023 8:41:31 AM 5 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0246
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 6/13/2022 Etrakit Contractor 1ST SUBMITTAL SITE
PLAN Lot54A_COMPLETE.pdf 1
DOC 7/1/2022 JULIO ANAYA
SITE PLAN AND
ENGINEERING
(APPROVED)
BPOL2022-0246 - SITE
PLAN AND
ENGINEERING
(APPROVED).pdf
1
BOND INFORMATION
FINAL**JAN 5/11/2023 5/11/2023 APPROVED eTRAKiT Inspection
Request
5/10/2023 2:42 PM F P D SERVICES INC DBA
STOKER POOLS
Contact Name: F P D SERVICES INC DBA
STOKER POOLS
Site Address: 53060 ROSS AVE
Phone: 7607721111
e-Mail: ACCOUNTING@STOKERPOOLS.COM
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST BLDG NS -
ETRAKIT (1 DAY)
JULIO ANAYA 6/13/2022 6/14/2022 7/1/2022 APPROVED
PARENT PROJECTS
Printed: Tuesday, October 24, 2023 8:41:31 AM 6 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2022-0246
AVENUE 54
BAFFIN AVE.ROSS AVE.F
R
E
M
O
N
T
W
A
Y
PIKE PL.PEARLY PL.MONROE STMADISON STAVENUE 52
COLUMBIA WAY
AMUN
DS
O
N AVE.
SITE MERIWETHER WAYHUMBOLDT BLVDMERIWETHER WAYHUMBOLDT BLVDROSS
A
V
E.
ELS
W
O
R
T
H
DE S
O
T
OSHACKLETON
SHEET INDEXVICINITY MAP
CUSTOM POOL, SPA & WATER FEATURES
FOR
LOT 54A RESIDENCE
53-060 ROSS AVE.
LA QUINTA, CA 92253
GENERAL NOTES
TITLE
SP-1.0 COVER SHEET
SP-2.0 SITE PLAN
SP-3.0 ENLARGED POOL/SPA PLAN
SP-3.1 SECTIONS & DETAILS
SP-3.1 ENTRY WATER FEATURE
SP-4.0 PLUMBING PLAN
SP-4.1 LIGHTING PLAN
S-1 ENGINEERING SITE PLAN
S-2 ENGINEERING DETAILS
S-3 ENGINEERING DETAILS
NO.
ABBREVIATIONS REFERENCE SYMBOLS CITY OF LA QUINTA NOTES
100'-0"
F.F. ELEV.
GRIDLINE
ELEVATION MARKER
DETAIL CALLOUT
SECTION CUTSHEET
NO
SHEET
NO
14 MATERIAL KEYNOTE
CONCRETE
GRAVEL
EARTH
WOOD FINISH
CONCRETE MASONRY UNIT
STONE
GUNITE
WATER (SURFACE)
WATER (SECTION)
1
ELEVATION CALLOUTSHEET
NO
IFINISH KEYNOTE
GRASS
F-1
POOL LIGHT
POOL DRAIN
SPILL
MAIN DRAIN SUCTION - 3' MIN. SEPARATION
UMBRELLA SLEEVE
POOL RETURN
SKIMMER
AUTO FILL
DECK JET
AQUASTAR 4" FLOOR RETURN BLACK
VACUUM PORT W/ VACUUM LOCK
J
01 POOL EQUIPMENT TAG
GENERAL NOTES:
1. PROPOSED CONSTRUCTION WILL CONFORM TO THE CURRENT CODES (CBC 106.1.1)
2019 California Residential Code, Title 24 Part 2.5
2019 California Electrical Code, Title 24 Part 3
2019 California Mechanical Code, Title 24 Part 4
2019 California Plumbing Code, Title 24 Part 5
2019 California Energy Code, Title 24 Part 6
2019 California Fire Code, Title 24 Part 9
2. GOVERNMENT CODE SECTION 4216.2. (A) (1) EXCEPT IN AN EMERGENCY, ANY PERSON
PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE
REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE
THAN 14 CALENDAR DAYS, PRIOR TO COMMENCING THAT EXCAVATION, IF THE
EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY
SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE
UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND, IF
PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER
SUITABLE MARKINGS THE AREA TO BE EXCAVATED.
3. THE CITY BUILDING INSPECTOR HAS THE AUTHORITY TO REQUEST FULLY REVISED
PLAN SHEETS WITH ALL FIELD CHANGES CLOUDED WITH DELTAS TO BE SUBMITTED
FOR CITY PLAN REVIEW WHEN HE/SHE DETERMINES THE NUMBER OF FIELD
REVISIONS WARRANT SUCH A REQUEST.
ELECTRICAL NOTES:
1. THE EQUIPMENT BONDING GRID SHALL EXTEND UNDER PAVED AND UNPAVED
SURFACES FOR 3 FEET HORIZONTALLY BEYOND THE INSIDE WALLS OF THE POOL.
2. ALL METAL-SHEATHED CABLES AND RACEWAYS, METAL PIPING, AND ALL FIXED METAL
PARTS THAT ARE WITHIN THE FOLLOWING DISTANCES OF THE POOL, EXCEPT
THOSE SEPARATED FROM THE POOL BY A PERMANENT BARRIER, SHALL BE
BONDED:
A.) WITHIN 5 FEET HORIZONTALLY OF THE INSIDE WALLS OF THE POOL.
B.) WITHIN 12 FEET MEASURED VERTICALLY ABOVE THE MAXIMUM WATER LEVEL OF
THE POOL, OR ANY SLIDES, DIVING BOARDS ETC...
3. PROVIDE 36" WORKING CLEARANCES FOR THE POOL EQUIPMENT DISCONNECT AND
SUB PANEL (CEC ART 110.26)
4. LOAD CALCS - USE EXISTING ELECTRICAL FEED TO POOL EQUIPMENT
5. SINGLE LINE DIAGRAM - SEE BUILDING PERMIT AND APPROVED PLANS
6. NO OVERHEAD UTILITY/SERVICE LINES ARE IN THE VICINITY OF THE NEW POOL OR
SPA
7. ALL OUTLETS SUPPLIED BY SINGLE PHASE, 15A AND 20A, 125V OR 240V BRANCH
CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI
PROTECTION. THIS APPLIES TO OUTLETS REGARDLESS OF THEIR PROXIMITY TO
THE SWIMMING POOL AND IT APPLIES TO CORD-AND-PLUG CONNECTED AND DIRECT
CONNECTED SWIMMING POOL PUMP MOTORS. CEC 680.22 (B)
MECHANICAL/PLUMBING NOTES:
1. ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS
AND IN ACCORDANCE WITH LOCAL REGULATIONS.
2. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED.
3. GAS ISOMETRIC: - NEW 2" PE GAS LINE WITH TRACER WIRE, ±100 LINEAL FEET.
2019 ENERGY EFFICIENCY STANDARDS MANDATORY MEASURES (MF-1R)
1.ANY POOL OR SPA HEATING SYSTEM SHALL BE CERTIFIED TO HAVE: A THERMAL
EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AN
ON-OFF SWITCH MOUNTED OUTSIDE OF THE HEATER; A PERMANENT
WEATHERPROOF PLATE OR CARD WITH OPERATING INSTRUCTIONS; AND SHALL
NOT USE ELECTRIC RESISTANCE HEATING OR A PILOT LIGHT.
2.ANY POOL OR SPA HEATING EQUIPMENT SHALL BE INSTALLED WITH AT LEAST 36"
OF PIPE BETWEEN FILTER AND HEATER, OR DEDICATED SUCTION AND RETURN
LINES, OR BUILT-UP CONNECTIONS FOR FUTURE SOLAR HEATING.
3.OUTDOOR POOLS OR SPAS THAT HAVE A HEAT PUMP OR GAS HEATER SHALL HAVE
A COVER.
4.POOLS SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL
WATER, AND A TIME SWITCH THAT WILL ALLOW ALL PUMPS TO BE SET OR
PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIODS.
5.RESIDENTIAL POOL SYSTEMS OR EQUIPMENT MUST MEET THE PUMP SIZING, FLOW
RATE, PIPING AND FILTERS.
EQUIPMENT NOTES/MANDATORY REQUIREMENTS
1.ANY POOL OR SPA HEATING SYSTEM OR EQUIPMENT MAY BE INSTALLED ONLY IF
THE MANUFACTURER HAS CERTIFIED THAT THE SYSTEM OR EQUIPMENT HAS ALL
OF THE FOLLOWING: EFFICIENCY - A THERMAL EFFICIENCY THAT COMPLIES WITH
THE APPLIANCE EFFICIENCY REGULATIONS; AND ON-OFF SWITCH - A READILY
ACCESSIBLE ON-OFF SWITCH, MOUNTED ON THE OUTSIDE OF THE HEATER THAT
ALLOWS SHUTTING OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT
SETTING; AND INSTRUCTIONS - A PERMANENT, EASILY READABLE , AND
WEATHERPROOF PLATE OR CARD THAT GIVES INSTRUCTION FOR THE ENERGY
EFFICIENT OPERATION OF THE POOL OR SPA HEATER AND FOR THE PROPER CARE
OF POOL OR SPA WATER WHEN A COVER IS USED; AND ELECTRIC RESISTANCE
HEATING - NO ELECTRIC RESISTANCE HEATING; AND
1.1.EXCEPTION 1 TO SECTION 114 (A)4: LISTED PACKAGE UNITS WITH FULLY
INSULATED ENCLOSURE, AND WITH TIGHT-FITTING COVERS THAT ARE
INSULATED TO AT LEAST R-6.
1.2. EXCEPTION 2 TO SECTION 114(A)4: POOLS OR SPAS DERIVING AT LEAST 60
PERCENT OF THE ANNUAL HEATING ENERGY FROM SITE SOLAR ENERGY OR
RECOVERED ENERGY.
2.ANY POOL OR SPA SYSTEM OR EQUIPMENT SHALL BE INSTALLED WITH ALL OF THE
FOLLOWING:
PIPING - SEE MANDATORY MEASURES NOTE #2
COVERS - SEE MANDATORY MEASURES NOTE #3
DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS - SEE MANDATORY
MEASURES NOTE #4
3.ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03 FORM TO BE
COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE
BUILDING INSPECTOR PRIOR TO FINAL INSPECTION APPROVAL,
4.DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS. IF THE SYSTEM OR
EQUIPMENT IS FOR A POOL:
4.1.THE POOL SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL
WATER; AND
4.2. A TIME SWITCH OR SIMILAR CONTROL MECHANISM SHALL BE INSTALLED AS
PART OF THE POOL WATER CIRCULATION CONTROL SYSTEM THAT WILL ALLOW
ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK
ELECTRIC DEMAND PERIOD, AND FOR THE MINIMUM TIME NECESSARY TO
MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC
HEALTH STANDARDS.
5.ALL PUMPS AND PUMP MOTORS INSTALLED SHALL BE LISTED IN THE
COMMISSIONS'S DIRECTORY OF CERTIFIED EQUIPMENT AND SHALL COMPLY WITH
THE APPLIANCE EFFICIENCY REGULATIONS.
6.FILTRATION PUMPS SHALL BE SIZED, OR IF PROGRAMMABLE, SHALL BE
PROGRAMMED, SO THAT THE FILTRATION FLOW RATE IS NOT GREATER THAN THE
RATE NEEDED TO TURN OVER THE POOL WATER VOLUME IN 6 HOURS OR 36 GPM,
WHICHEVER IS GREATER.
7.PUMP MOTORS USED FOR FILTRATION WITH A CAPACITY OF 1 HP OR MORE SHALL
BE MULTI SPEED.
8.EACH AUXILIARY POOL LOAD SHALL BE SERVED BY EITHER SEPARATE PUMPS OR
THE SYSTEM SHALL BE SERVED BY A MULTI SPEED PUMP. EXCEPTION - PUMPS
LESS THAN 1 HP MAY BE SINGLE SPEED.
9.MULTI SPEED PUMPS SHALL HAVE CONTROLS WHICH DEFAULT TO THE FILTRATION
FLOW RATE WHEN NO AUXILIARY POOL LOADS ARE OPERATING.
10.FOR MULTI SPEED PUMPS, THE CONTROLS SHALL DEFAULT TO THE FILTRATION
FLOW SETTING WITHIN 24 HOURS AND SHALL HAVE AN OVERRIDE CAPABILITY FOR
SERVICING.
11.A LENGTH OF STRAIGHT PIPE THAT IS GREATER THAN OR EQUAL TO AT LEAST 4
PIPE DIAMETERS SHALL BE INSTALLED BEFORE THE PUMP.
12.POOL PIPING SHALL BE SIZED SO THAT THE VELOCITY OF THE WATER AT MAXIMUM
FLOW FOR AUXILIARY POOL LOADS DOES NOT EXCEED 8 FEET PER SECOND IN THE
RETURN LINE AND 6 FEET PER SECOND IN THE SUCTION LINE.
13.ALL ELBOWS SHALL BE SWEEP ELBOWS OR ELBOW-TYPE THAT HAVE A PRESSURE
DROP OF LESS THAN THE PRESSURE DROP OF STRAIGHT PIPE WITH A LENGTH OF
30 PIPE DIAMETERS.
14.FILTERS SHALL BE AT LEAST THE SIZE SPECIFIED IN NSF/ANSI 50 FOR PUBLIC POOL
INTENDED.
15.MINIMUM DIAMETER OF BACKWASH VALVES SHALL BE 2 INCHES OF THE DIAMETER
OF THE RETURN PIPE, WHICHEVER IS GREATER.
SAFETY STANDARDS
SECTION AV100.3 OF THE 2016 C.R.C. ADDRESSES THE POOL SAFETY STANDARDS FOR
POOLS, SPAS AND HOT TUBS INSTALLED FOR SINGLE FAMILY RESIDENCE.
FOR THE PURPOSE OF THIS CODE THE FOLLOWING DEFINITIONS ARE APPLICABLE:
SWIMMING POOL: ANY STRUCTURE INTENDED FOR SWIMMING OR RECREATIONAL
BATHING THAT CONTAINS WATER OVER 18 INCHES DEEP.
ENCLOSURE: A FENCE, WALL, OR OTHER BARRIER THAT ISOLATES A SWIMMING
POOL FROM ACCESS TO THE HOME
ENCLOSURE REQUIREMENTS:
AN OUTDOOR SWIMMING POOL, INCLUDING HOT TUBS OR SPAS SHALL BE SURROUNDED
BY A BARRIER WHICH SHALL COMPLY WITH THE FOLLOWING:
1. TOP OF THE BARRIER SHALL BE AT LEAST 60 INCHES ABOVE GRADE MEASURED ON
THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL
1.1. OPENINGS IN TECH BARRIER SHALL NOT ALLOW THE PASSAGE OF A 4 INCH DIA.
SPHERE.
1.2. OPENING BETWEEN THE FINISH GRADE AND THE BOTTOM OF THE BARRIER
SHALL BE MAX. 2 INCHES.
1.3. BARRIERS SHALL BE INSTALLED SO AS NOT HAVE ANY FEATURES WHICH AID IN
CLIMBING.
2. ACCESS GATES SHALL BE A MINIMUM OF 60 INCHES ABOVE GRADE AND SHALL BE
SELF CLOSING AND HAVE SELF LATCHING DEVICE. GATES MUST OPEN OUTWARD
FROM THE POOL. GATES SHALL MEET THE SAME PROVISIONS AS LISTED AS
BARRIERS.
3. OUTSIDE SURFACES SHALL BE FREE OF ANYTHING THAT CAN MAKE THE BARRIER
CLIMBABLE
4. IF USING THE WALL OF THE HOUSE AS AN ENCLOSURE, EXIT ALARMS MUST BE
PLACE ON ALL DOORS THAT PROVIDE DIRECT ACCESS TO THE POOL.
SUCTION OUTLETS:
1. POOLS AND SPAS MUST HAVE AT LEAST TWO CIRCULATION OUTLETS, WHICH ARE
HYDRAULICALLY BALANCED AND SEPARATED BY THREE FEET OR
2. UTILIZATION OF SKIMMERS, PERIMETER OVERFLOW SYSTEMS, OR OTHER
PRE-APPROVED DEVICES IN LIEU OF TRADITIONAL SUCTION DEVICES.
3. THE USE OF OTHER OUTLET DEVICES WHICH MAY MEET ANSI/APSP-7 STANDARDS
BUT DO NOT HAVE A MINIMUM OF THREE FEET BETWEEN OUTLETS IS PROHIBITED.
WORK HOURS
ANY AND ALL WORK WITHIN THE COMMUNITY WILL TAKE PLACE ONLY DURING THE
FOLLOWING HOURS:
SEASON DAYS OF WEEK TIME
OCT 1ST-APR 30 MONDAY -FRIDAY 7:00 AM-5:30 PM
SATURDAY 8:00 AM-5:00 PM
MAY 1ST-SEP 30 MONDAY -FRIDAY 6:00 AM-7:00 PM
SATURDAY 8:00 AM-5:00 PM
ALL SEASONS SUNDAY AND HOLIDAYS NONE
ALL CONSTRUCTION PERSONNEL SHALL VACATE THE COMMUNITY WITHIN THIRTY (30)
MINUTES OF THE END OF THE PERMITTED WORK HOURS. GUARDS AT THE GATE WILL
PERMIT ENTRY DURING THESE HOURS ONLY. IT IS THE RESPONSIBILITY OF THE OWNER
TO NOTIFY THE GATE OF THE DATE, TIMES AND NAMES OF CONSTRUCTION PERSONNEL
AND OTHER VENDORS WHO MAY REQUIRE ENTRY.
MD
U
R
SK
AF
D
FR
VP
SHEET:
DATE:
SCALE:
DWN BY: CE
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 820132SP-1.0COVER SHEETN.T.S.
6/7/2022LOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253CBP
07/01/2022J.ANAYA
BPOL2022-0246
DISCOVERY LLC / POOL,SPA AND [2] WATER FEATURES AT REAR AND
FRONT YARDS. TWO DROWNING SAFETY FEATURES AND BARRIERS
REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PLEASE
PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR
INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN
APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5'
MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING
CODE.
up
up
up
up
15'-3"
PRO
P
E
R
T
Y
LI
N
E
PRO
P
E
R
T
Y
LI
N
E
PROPERTY LINEPROPERTY LINE11'-11"
2
SP-3.1
RESIDENCE
WATER FEATURE
POOL
SPA
POOL EQUIPMENT
LOCATION
10'-4"
9'-8"
1
SP-3.2
WATER FEATURE
9'-3"
8'-3"
11'-11"30X36 CLRG
(2) NEW 2'' P.E. PIPE W/TRACER
WIRE 147 L.F. 400,000 BTU EACH
ALL DOORS ALARM 85 dBA
SELF CLOSING GATE WITH
SELF LATCHING DEVICE
6'-61
8"
SP-2.0SITE PLANLOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201326/8/2022
SITE PLAN
SCALE: 1/16"=1'-0"
CBP
07/01/2022J.ANAYA
39'-9"
17'-6"
14'-6"
16'-6"
32'-4"
13'-11
2"
62'
18'-9"23'
90'-9"
1'-3"1'-3"1'-3"1'-3"
5'
TANNING SHELF
POOL
SPA
W.D. -7''
W.D.
-15''
W.D.
-23''
W.D.
-31''
W.D.
-39''
W.D. -47''
19'-6"25'-6"
1'
W.D. -60''
W.D. -60''
10'-6"
1'
51'
W.D.
-7''
W.D.
-14''
W.D. -54''
1'-6"
14'
1'-6"23'1'-6"23'
W.D. -22''
W.D. -42''
2'
1'-3"
1'-6"
1'-6"
2'-6"
W.D.
-33''
W.D. -52''
W.D. -52''
TANNING
SHELF
W.D. -7''
1'-3"1'-3"1'-3"1'-3"1'-3"
2'-11
2"1'1'
W.D.
-16''
W.D.
-25''
W.D.
-34''
W.D.
-43''
W.D.
-52''
A2
SP-3.1
A3
SP-3.1
A5
SP-3.1
A4
SP-3.1
A6
SP-3.1
A2
SP-3.1
13'
1'-6"
30'-41
2"
WATER SPEC'S
POOL
SIZE
DEPTH
PERIMETER
AREA
VOLUME
SPA
SIZE
DEPTH
PERIMETER
AREA
VOLUME
49' x 90'-9''
3' - 5'
279'-7'' I.F.
2,681 S.F.
18'-9'' x 16'-6''
4'-6"
70'-6'' I.F.
309 S.F.SP-3.0ENLARGED POOL PLANLOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201326/7/2022A
SCALE: 1/4''=1'-0"
ENLARGED POOL
CBP
07/01/2022J.ANAYA
TANNING SHELF BEYOND
8"
8"
8"
8"
8"
7"
1'-3"1'-3"1'-3"1'-3"
1
SP-3.0
WATERLINE
3'-11"
3'-4"
7"
1
SP-3.0
WATERLINE
10"
1'-0"
6"4"9"6"
6"
10"
4"
1"
WATERLINE
6'' WATERLINE TILE/STONE
PEBBLE SHEEN FINISH T.B.D.
TILE/ STONE MITER ALL CORNERS4'' CONCRETE S.O.G.
TILE / STONE & SETTING BED
GUNITE WALL PER PLAN
5"
1"
1"
FINISH FLOOR
WATERLINE
6'' WATERLINE
TILE/STONE
4'' CONCRETE S.O.G.
NATURAL GRADE
TILE/STONE TO
TROUGH FLOOR
1'' FIBERGLASS GRATE
PEBBLE SHEEN
FINISH T.B.D
GUNITE WALL
TILE/STONE CAP
VARIES
6"6"
1"
4"
3'-7"
6"
2'10"
1
SP-3.0
WATERLINE
1'
1'-8"
1'-10"
1'
1'-8"
1'-10"
2'-6"1'-6"10"2'-6"1'-6"
4'-10"30X36 CLR1'-3"6"2'6"1'-3"6"2'6"1'-3"6"2'
6"
6"
6"
1'-3"
6"
1'-3"
6"
1'-3"
6"
1'-3"
6"
1'-3"
6"
1'-3"
33
8"
EQUIPMENT RACK FOR HEATERS
1
SP-3.0
WATERLINE
TANNING SHELF BEYOND
2'-11
2"1'-3"1'-3"1'-3"1'-3"1'-3"
9"
9"
9"
9"
9"
9"
7"
5'-1"
1
SP-3.0
WATERLINE
8'-41
2"
7"
5'-1"
4'-6"
2'-6"
1'
2'-6"
1'
2'-6"61
2"
1'-2"
EQUIPMENT RACK FOR HEATERS
SP-3.1SECTIONS & DETAILSLOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201326/7/2022
A3
SCALE: 1/2''=1'-0"
STEPS DETAIL
A2
SCALE: 1/2''=1'-0"
TANNING SHELF DETAIL
1
SCALE: 1-1/2''=1'-0"
COPING DETAIL
A1
SCALE: 3/4''=1'-0"
TROUGH DETAIL
A6
SCALE: 1/2''=1'-0"
SPA SECTION
2
SCALE: 1/4''=1'-0"
POOL EQUIPMENT
A4
SCALE: 1/2''=1'-0"
STEPS DETAIL A5
SCALE: 1/2''=1'-0"
TANNING SHELF DETAIL
2
SCALE: 1/4''=1'-0"
STACKED POOL EQUIPMENT
CBP
07/01/2022J.ANAYA
A1
SP-3.2
A1
SP-3.2
A2
SP-3.2
A2
SP-3.2
1'-3"
14'
8"
8"
1'1'
12'' CMU WALL
A2
SP-3.2
A2
SP-3.2
F.S.
5' METAL SCREEN (BY OTHERS)
12'' CMU WALL (BY OTHERS)
WATER FEATURE
12'' CMU WALL
(BY OTHERS)
5' METAL SCREEN WALL
(BY OTHERS)
1'-3"
3"
6"1'-5"6"
14'
6"
FOUNTAIN BASIN
6"
1'-3"
3"
WATER LINE
6"
SP-3.2ENTRY WATER FEATURELOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201326/7/2022
A2
SCALE: 3/4''=1'-0"
WATER FEATURE SECTION
1
SCALE: 1/4=1'-0"
ENTRY WATER FEATURES
A1
SCALE: 1/4''=1'-0"
WATER FEATURE ELEVATION
A5
SCALE: 1/2''=1'-0"
WATER FEATURE DETAIL
CBP
07/01/2022J.ANAYA
AF
MD
R2
R2R2
R2R1
R1
R3
R3
MDMDMDMDMDMDMD
MD
MD
MD
MD
3'' PVC
TO P-01
3'' PVC TO P-05
3'' PVC TO P-09
3'' PVC TO P-07
2-1/2'' PVC TO P-03
3'' PVC TO P-08
2-1/2'' PVC FROM H-03
3'' PVC
TO P-02
3'' PVC
TO P-03
3'' PVC
TO P-04
3'' PVC TO P-06
2-1/2'' PVC FROM H-02
2-1/2'' PVC FROM H-01
3/4'' PVC FILL LINE
1'' CONDUIT TO LEVOLOR
R3R3R3R4R4
R4R5R5R5
3'' PVC FROM P-06
3'' PVC FROM P-04
3'' PVC FROM P-05
2-1/2'' PVC TO P-01
2-1/2'' PVC TO P-02
FR
AF
SK
MD
R
FLOOR RETURN
RETURN
AUTO FILL
SKIMMER
MAIN DRAIN
LIGHT
FLOOR UP LIGHT
DOUBLE SPA JETS
LOW SPA JET
MID SPA JET
HIGH SPA JET
DBL
MID
LO
HI SP-4.0PLUMBING PLANLOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201326/7/2022
A
SCALE: 1/4''=1'-0"
PLUMBING PLAN
CBP
07/01/2022J.ANAYA
4'
3'-9"
3'-9"
3'-9"
5'-41
2"7'7'7'7'7'
7'
7'
3'-9"
7'
3'-9"
7'7'
8'
3'-9"
7'7'
7'
7'
7'
4'-7"4'-7"
POOL LIGHT SCHEDULE
TYPE LOCATION MFR MODEL NO.QTY
6W SPA JANDY JLU4C6W100 3
24W POOL JANDY JLU4C24W100 16
6W TANNIING SHELFS JANDY JLU4C6W100 6
FR
AF
SK
MD
R
FLOOR RETURN
RETURN
AUTO FILL
SKIMMER
MAIN DRAIN
LIGHT
FLOOR UP LIGHT
DOUBLE SPA JETS
LOW SPA JET
MID SPA JET
HIGH SPA JET
DBL
MID
LO
HI
SP-4.1LIGHTING PLANLOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201326/7/2022
A
SCALE: 1/4''=1'-0"
LIGHTING PLAN
CBP
07/01/2022J.ANAYA
up
up
up
up
15'-3"
PRO
P
E
R
T
Y
LI
N
E
PRO
P
E
R
T
Y
LI
N
E
PROPERTY LINEPROPERTY LINE11'-11"
2
SP-3.1
RESIDENCE
WATER FEATURE
POOL
SPA
POOL EQUIPMENT
LOCATION
10'-4"
9'-8"
1
SP-3.2
WATER FEATURE
9'-3"
8'-3"
11'-11"30X36 CLRS-1 ENGINEERING SITE PLANLOT 54A53-060 ROSS AVENUELA QUINTA, CA 92253SHEET:
DATE:
SCALE:
DWN BY: CRAIG
dateno.revisions760-702-111143653 Parkway EsplanadeLa Quinta, CA 92253Stokerpools.com Lic# 8201326/7/2022
SITE PLAN
SCALE: 1/16"=1'-0"
651
C-100649
552
649
100 100
649
552
202
Authentication Code = dg#22-08768@11%50a060922
07/01/2022J.ANAYA
S-2
SHEET:
07/01/2022J.ANAYA
S-3
SHEET:
07/01/2022J.ANAYA