BRES2021-0250 - Title 24CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 1 of 17)
GENERAL INFORMATION
01
Project Name
Lot 9A Project
02
Run Title
Title 24 Analysis
03
Project Location
52-435 Ross Ave Madison Club CC
04
City
La Quinta
05
Standards Version
2019
06
Zip code
92253
07
Software Version
EnergyPro 8.1
08
Climate Zone
15
09
Front Orientation (deg/ Cardinal)
225
10
Building Type
Single family
11
Number of Dwelling Units
1
12
Project Scope
NewConstruction
13
Number of Bedrooms
8
14
Addition Land_ Floor Area (ft2)
0
15
Number of Stories
1
16
Existing Cond. Floor Area (ftx)
nfa
17
Fenestration Average U-factor
0.49
18
Total Cond. Floor Area (ft)
9698
19
Glazing Percentage (%)
29.41%
20
ADU Bedroom Count
0
21
ADU Conditioned Floor Area
0
22
Is Natural Gas Available?
Yes
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
REVISION 1
BRES2021-0250
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE04/14/2022 BY -1 F7
PV SYSTEM CHANGES
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: Lot 9A Project Calculation Date/Time: 2022-03-31T11:26:34-07:00 (Page 2 of 17)
Calculation Description: Title 24 Analysis Input File Name: Lot 9A Madison Club.ribdl9x
ENERGY DESIGN RATING
Energy Design Ratings
Compliance Margins
Efficiency' (EDR)
TotalZ (EDR)
Efficiency' (EDR)
TotalZ (EDR)
Standard Design
38.4
19.8
Proposed Design
37.7
8.4
0.7
11.4
RESULT: 3' COMPLIES
1: Efficiency EDR includes improvements to the building envelope and more efficient equipment
2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
3: Building complies when efficiency and total compliance margins are greater than or equal to zero
• Standard Design PV Capacity: 12.35 kWdc
• Proposed PV kWh output exceeds proposed electricity use by 37% which may violate NEM rules. Contact local utility.
ENERGY USE SUMMARY
Energy Use (kTDV/ftz-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.8
5.44
-2.64
-94.3
Space Cooling
69.29
67.02
2.27
3.3
IAQ Ventilation
1.99
1.99
0
0
Water Heating
2.42
5.68
-3.26
-134.7
Self Utilization Credit
n/a
-5.26
5.26
n/a
Compliance Energy Total
76.5
74.87
1.63
2.1
REQUIRED PV SYSTEMS - SIMPLIFIED
01
02
03
04
05
06
07
08
09
10
11
12
DC System Size
Exception
Module Type
Array Type
Power Electronics
CFI
Azimuth
Tilt
Array Angle
Tilt: (x in 12)
Inverter Eff.
Annual
Solar Access
(kWdc)
(deg)
Input
(deg)
N
(%)
20
NA
Premium
Fixed (r) f
Microinverters
false
180
Degrees
0
0
98
100
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 3 of 17)
ENERGY DESIGN RATING BATTERY INPUTS
01
02
03
04
05
06
Control
Capacity (kWh)
Charging Efficiency
Rate (kW)Rate (kW)
Discharging Efficiency
Rate (kW)Rate (kW)
Basic
20
0.95
n/a
0.95
n/a
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Battery System: 20 kWh (Self Utilization Credit taken)
• Cool roof
• Insulation above roof deck
• Insulation below roof deck
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level Verifications:
• Quality insulation installation (QII)
• Building air leakage/reduced infiltration
• Indoor air quality ventilation
• Kitchen range hood
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
Heating System Verifications:
• Verified HSPF
• Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
• Duct leakage testing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• Pipe Insulation, All Lines
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 4 of 17)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftz)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Lot 9A Project
9698
1
8
6
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ft)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
Zone 4
Conditioned
HVAC System 41
1362
12
DHW Sys 1
N/A
Zone 5
Conditioned
HVAC System 52
1302
12
DHW Sys 1
N/A
Zone 6
Conditioned
HVAC System 63
1869
12
DHW Sys 1
N/A
Zone 1
Conditioned
HVAC System 14
1361
12
DHW Sys 1
N/A
Zone 2
Conditioned
HVAC System 25
2271
12
DHW Sys 1
N/A
Zone 3
Conditioned
HVAC System 36
1533
12
DHW Sys 1
N/A
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Tilt (deg)
Area (ft2)
Northeast Exterior Wall
Zone 4
R-21 Wall
45
Back
456
192
90
Southwest Exterior
Zone 4
R-21 Wall
225
Front
660
212.515
90
Wall
Northwest Exterior
Zone 4
R-21 Wall
315
Left
360
72.6
90
Wall
Northeast Exterior Wall
Zone 5
R-21 Wall
45
Back
780
459
90
2
Southwest Exterior
Zone 5
R-21 Wall
225
Front
780
36
90
Wall 2
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 5 of 17)
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window and Door
Tilt (deg)
Area (ft2)
Northwest Exterior
Zone 5
R-21 Wall
315
Left
532
196
90
Wall 2
Southeast Exterior Wall
Zone 6
R-21 Wall
135
Right
616
100
90
Southwest Exterior
Zone 6
R-21 Wall
225
Front
756
224
90
Wall 3
Northeast Exterior Wall
Zone 1
R-21 Wall
45
Back
420
24
90
3
Southwest Exterior
Zone 1
R-21 Wall
225
Front
420
216
90
Wall 4
Northwet Exterior Wall
Zone 1
R-21 Wall
315
Left
686
132.99
90
Northeast Exterior Wall
Zone 2
R-21 Wall
45
Back
110
21
90
4
Southwest Exterior
Zone 2
R-21 Wall
225
Front
880
668
90
Wall 5
Northeast Exterior Wall
Zone 3
R-21 Wall
45
Back
620
384
90
5
Southeast Exterior Wall
Zone 3
R-21 Wall
135
Right
120
32
90
2
Roof
Zone 4
R-38 HP Attic 38-21+6
n/a
n/a
1362
n/a
n/a
Roof 2
Zone 5
R-38 HP Attic 38-21+6
n/a
n/a
1302
n/a
n/a
Roof 3
Zone 6
R-38 HP Attic 38-21+6
n/a
n/a
1869
n/a
n/a
Roof 4
Zone 1
R-38 HP Attic 38-21+6
n/a
n/a
1361
n/a
n/a
Roof 5
Zone 2
R-38 HP Attic 38-21+6
n/a
n/a
2271
n/a
n/a
Roof 6
Zone 3
R-38 HP Attic 38-21+6
n/a
n/a
1533
n/a
n/a
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 6 of 17)
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise (x in 12)
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Zone 4
Attic RoofZone 4
Unventilated
0
0.79
0.9
No
Yes
Attic Zone 5
Attic RoofZone 5
Unventilated
0
0.79
0.9
No
Yes
Attic Zone 6
Attic RoofZone 6
Unventilated
0
0.79
0.9
No
Yes
Attic Zone 1
Attic RoofZone 1
Unventilated
0
0.79
0.9
No
Yes
Attic Zone 2
Attic RoofZone 2
Unventilated
0
0.79
0.9
No
Yes
Attic Zone 3
Attic RoofZone 3
Unventilated
0
0.79
0.9
No
Yes
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
MuIt.
Area
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
e
Exterior
Shading
Window D-48
Window
Northeast Exterior Wall
Back
45
16
12
1
192
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-09
Window
Southwest Exterior Wall
Front
225
1
12.5
0.31
NFRC
0.24
NFRC
Bug Screen
Window D-46
Window
Southwest Exterior Wall
Front
225
1
72
0.51
NFRC
0.23
NFRC
Bug Screen
Window D-49
Window
Southwest Exterior Wall
Front
225
10.7
12
0
121.0
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-08
Window
Northwest Exterior Wall
Left
315
1
72.6
0.31
NFRC
0.24
NFRC
Bug Screen
Window D-41
Window
Northeast Exterior Wall 2
Back
45
36
12
1
432
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-10
Window
Southwest Exterior Wall 2
Front
225
1
12
0.31
NFRC
0.24
NFRC
Bug Screen
Window W-11
Window
Southwest Exterior Wall 2
Front
225
1
12
0.31
NFRC
0.24
NFRC
Bug Screen
Window W-12
Window
Southwest Exterior Wall 2
Front
225
1
12
0.31
NFRC
0.24
NFRC
Bug Screen
Window D-51
Window
Northwest Exterior Wall 2
Left
315
1
196
0.51
NFRC
0.23
NFRC
Bug Screen
Window D-31
Window
Southeast Exterior Wall
Right
135
7
10
1
70
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-15
Window
Southeast Exterior Wall
Right
135
1
30
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-13
Window
Southwest Exterior Wall 3
Front
225
4
3
1
12
0.47
NFRC
0.19
NFRC
Bug Screen
Window W-14
Window
Southwest Exterior Wall 3
Front
225
4
3
1
12
0.47
NFRC
0.19
NFRC
Bug Screen
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 7 of 17)
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
e
Exterior
Shading
Window D-37
Window
Southwest Exterior Wall 3
Front
225
10
10
1
100
0.51
NFRC
0.23
NFRC
Bug Screen
Window D-38
Window
Southwest Exterior Wall 3
Front
225
10
10
1
100
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-04
Window
Northeast Exterior Wall 3
Back
45
1
24
0.31
NFRC
0.24
NFRC
Bug Screen
Window D-22
Window
Southwest Exterior Wall 4
Front
225
1
216
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-05
Window
Northwet Exterior Wall
Left
315
5
5.5
1
28
0.43
NFRC
0.19
NFRC
Bug Screen
Window W-06
Window
Northwet Exterior Wall
Left
315
5
3.5
1
18.01
0.47
NFRC
0.19
NFRC
Bug Screen
Window W-07
Window
Northwet Exterior Wall
Left
315
5
3
1
15
0.31
NFRC
0.24
NFRC
Bug Screen
Window D-21
Window
Northwet Exterior Wall
Left
315
6
7
1
71.99
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-01
Window
Northeast Exterior Wall 4
Back
45
1
21
0.31
NFRC
0.24
NFRC
Bug Screen
Window D-23
Window
Southwest Exterior Wall 5
Front
225
36
12
1
432
0.51
NFRC
0.23
NFRC
Bug Screen
Window D-24
Window
Southwest Exterior Wall 5
Front
225
17
12
1
204
0.51
NFRC
0.23
NFRC
Bug Screen
Window W-01 2
Window
Northeast Exterior Wall 5
Back
45
1
21
0.31
NFRC
0.24
NFRC
Bug Screen
Window W-02
Window
Northeast Exterior Wall 5
Back
45
1
21
0.47
NFRC
0.19
NFRC
Bug Screen
Window W-03
Window
Northeast Exterior Wall 5
Back
45
1
15
0.47
NFRC
0.19
NFRC
Bug Screen
Window D-09
Window
Northeast Exterior Wall 5
Back
45
10
10
1
100
0.51
NFRC
0.23
NFRC
Bug Screen
Window D-10
Window
Northeast Exterior Wall 5
Back
45
10
10
1
100
0.51
NFRC
0.23
NFRC
Bug Screen
Window D-15
Window
Northeast Exterior Wall 5
Back
45
10
1 10
1
100
0.51
NFRC
0.23
1 NFRC
Bug Screen
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ftz)
U-factor
Door D-53
Northeast Exterior Wall 2
27
0.5
Doo D-25
Southwest Exterior Wall 5
32
0.5
Door D-04
Northeast Exterior Wall 5
27
0.5
Door D-26
Southeast Exterior Wall 2
32
0.5
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 8 of 17)
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
Window D-48
4
0.1
4
4
0
0
0
0
0
0
0
0
0
Window D-49
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window D-41
12
0.1
10
10
0
0
0
0
0
0
0
0
0
Window D-31
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window W-13
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window W-14
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window D-37
4
0.1
4
4
0
0
0
0
0
0
0
0
0
Window D-38
4
0.1
4
4
0
0
0
0
0
0
0
0
0
Window W-05
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window W-06
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window W-07
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window D-21
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window D-23
4
0.1
4
4
0
0
0
0
0
0
0
0
0
Window D-24
20
0.1
10
10
0
0
0
0
0
0
0
0
0
Window D-09
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window D-10
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window D-15
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 9 of 17)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value and Depth
Carpeted Fraction
Heated
Slab -on -Grade
Zone 4
1362
40
None
100%
No
Slab -on -Grade 2
Zone 5
1302
30
None
100%
No
Slab -on -Grade 3
Zone 6
1869
70
None
100%
No
Slab -on -Grade 4
Zone 1
1361
30
None
100%
No
Slab -on -Grade 5
Zone 2
2271
60
None
100%
No
Slab -on -Grade 6
Zone 3
1533
10
None
100%
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Inside Finish: Gypsum Board
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
R-21 Wall1
Interior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.064
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Attic RoofZone 4
Attic Roofs
Wood Framed
2x4 @ 24 in. O. C.
R-38
None / R 6
0.027
Roof Deck: Wood
Ceiling
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-25.0 insul.
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 10 of 17)
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Attic RoofZone 5
Attic Roofs
Wood Framed
2x4 @ 24 in. O. C.
R-38
None / R-6
0.027
Roof Deck: Wood
Ceiling
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-25.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Attic RoofZone 6
Attic Roofs
Wood Framed
2x4 @ 24 in. O. C.
R 38
None / R 6
0.027
Roof Deck: Wood
Ceiling
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-25.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Attic RoofZone 1
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R-38
None / R-6
0.027
Roof Deck: Wood
Ceiling
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-25.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Attic RoofZone 2
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R-38
None / R-6
0.027
Roof Deck: Wood
Ceiling
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-25.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Attic RoofZone 3
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R 38
None / R 6
0.027
Roof Deck: Wood
Ceiling
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-25.0 insul.
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 11 of 17)
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Continuous
U-factor
Assembly Layers
R-value
R 38 HP Attic 38 21+6
Ceilings (below
Wood Framed
2x12 @ 24 in. O. C.
R-22
None /None
0.035
Cavity / Frame: R-22.0 / 2x12
attic)
Ceiling
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Required
3879.2
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
Name
System Type
Distribution Type
Water Heater Name (#)
Solar Heating System
Compact Distribution
HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
HERS Verified Pipe
Insulation credit
DHW Heater 1 (4)
n/a
None
DHW Sys 1-hers dhw
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Tank
Heating
#
Tank
Energy
Input Rating
Insulation
Standby Loss
1st Hr. Rating
NEEA Heat Pump
Tank Location or
Name
Element
Tank Type
Units
Vol.
Factor or
or Pilot
R-value
or Recovery
or Flow Rate
Brand or Model
Ambient Condition
Type
(gal)
Efficiency
(Int/Ext)
Eff.
DHW Heater 1
Gas
Commercial
4
50
0.98 TE
> 100
0
0.020000
n/a
n/a
n/a
Storage
kBtu/hr
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 12 of 17)
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Type Compact Distribution
Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1- 1/4
Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
Heating Unit
Cooling Unit
Distribution
Required
Verified
Heating
Cooling
Name
System Type
Fan Name
Thermostat
Status
Existing
Equipment
Equipment
Name
Name
Name
Type
Condition
Count
Count
HVAC System 41
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 1
Air
Distribution
Setback
New
NA
1
1
System 1
System 1
System 1
HVAC System 52
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 2
Air
Distribution
Setback
New
NA
1
1
System 2
System 2
System 2
HVAC System 63
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 3
Air
Distribution
Setback
New
NA
1
1
System 3
System 3
System 3
HVAC System 14
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 4
Air
Distribution
Setback
New
NA
1
1
System 4
System 4
System 4
HVAC System 25
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 5
Air
Distribution
Setback
New
NA
1
1
System 5
System 5
System 5
HVAC System 36
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 6
Air
Distribution
Setback
New
NA
1
1
System 6
System 6
System 6
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 13 of 17)
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Heating
Cooling
Zonally
Compressor
Name
System Type
Number of Units
HERS Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Controlled
Type
Heat Pump System 1
Central split HP
1
11
59000
49500
21
13
Not Zonal
Multi-
Heat Pump System
speed
1-hers-htpump
Heat Pump System 2
Central split HP
1
11
59000
49500
21
13
Not Zonal
Multi-
Heat Pump System
speed
2-hers-htpump
Heat Pump System 3
Central split HP
1
11
59000
49500
21
13
Not Zonal
Multi-
Heat Pump System
speed
3-hers-htpump
Heat Pump System 4
Central split HP
1
10.5
45000
42500
22
13
Not Zonal
Multi-
Heat Pump System
speed
4-hers-htpump
Heat Pump System 5
Central split HP
1
11
59000
49500
21
13
Not Zonal
Multi-
Heat Pump System
speed
5-hers-htpump
Heat Pump System 6
Central split HP
1
11
59000
49500
21
13
Not Zonal
Multi-
Heat Pump System
speed
6-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
1-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
2-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
3-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
4-hers-htpump
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 14 of 17)
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
5-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
6-hers-htpump
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
12
Duct Ins. R-value
Duct Location
Surface Area
Name
Type
Design Type
Supply
Return
Supply
Return
Supply
Return
puts
Duct Leakage
HERS
Verification
Air
Air Distribution
NO
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 1
System
Duct
1-hers-dirt
Air
Air Distribution
No
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 2
System
Duct
2-hers-dirt
Air
Air Distribution
No
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 3
System
Duct
3-hers-dist
Air
Air Distribution
No
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 4
System
Duct
4-hers-dirt
Air
Air Distribution
NO
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 5
System
Duct
5-hers-dist
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 15 of 17)
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
12
Duct Ins. R-value
Duct Location
Surface Area
Name
Type
Design Type
Supply
Return
Supply
Return
Supply
Return
Bypass
Duct Leakage
HERS
Verification
Air
Air Distribution
NO
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 6
System
Duct
6-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
Target (%)
Location
Design
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
2.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 1-hers-dist
Air Distribution
Yes
2.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 2-hers-dirt
Air Distribution
Yes
2.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 3-hers-dirt
Air Distribution
Yes
2.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 4-hers-dirt
Air Distribution
Yes
2.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 5-hers-dist
Air Distribution
Yes
2.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 6-hers-dist
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 16 of 17)
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
Name
HVAC Fan 1
HVAC Fan
0.28
HVAC Fan 1-hers-fan
HVAC Fan 2
HVAC Fan
0.3
HVAC Fan 2-hers-fan
HVAC Fan 3
HVAC Fan
0.23
HVAC Fan 3-hers-fan
HVAC Fan 4
HVAC Fan
0.28
HVAC Fan 4-hers-fan
HVAC Fan 5
HVAC Fan
0.32
HVAC Fan 5-hers-fan
HVAC Fan 6
HVAC Fan
0.32
HVAC Fan 6-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.28
HVAC Fan 2-hers-fan
Required
0.3
HVAC Fan 3-hers-fan
Required
0.23
HVAC Fan 4-hers-fan
Required
0.28
HVAC Fan 5-hers-fan
Required
0.32
HVAC Fan 6-hers-fan
Required
0.32
IAQ (INDOOR AIR QUALITY) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SIRE
SFam IAQVentRpt
327
0.25
Default
0
n/a
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101
CERTIFICATE OF COMPLIANCE
Project Name: Lot 9A Project
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2022-03-31T11:26:34-07:00
Input File Name: Lot 9A Madison Club.ribdl9x
CF1R-PRF-01E
(Page 17 of 17)
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Butch White
3 ubcl v wvCtel
Company:
Signature Date:
Breeze Air Conditioning LLC
03/31/2022
Address:
CEA/ HERS Certification Identification (If applicable):
75-145 Street Charles Place
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 346-0855
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Butch White
3 tktc1 v W 7�Wel
Company:
Date Signed:
Breeze Air Conditioning LLC
03/31/2022
Address:
License:
75-145 Street Charles Place
1045015
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 346-0855
Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the
content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41
Schema Version: rev 20200101