Loading...
BRES2021-0250 - Title 24CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 1 of 17) GENERAL INFORMATION 01 Project Name Lot 9A Project 02 Run Title Title 24 Analysis 03 Project Location 52-435 Ross Ave Madison Club CC 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) 225 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 8 14 Addition Land_ Floor Area (ft2) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ftx) nfa 17 Fenestration Average U-factor 0.49 18 Total Cond. Floor Area (ft) 9698 19 Glazing Percentage (%) 29.41% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available? Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below REVISION 1 BRES2021-0250 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE04/14/2022 BY -1 F7 PV SYSTEM CHANGES Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name: Lot 9A Project Calculation Date/Time: 2022-03-31T11:26:34-07:00 (Page 2 of 17) Calculation Description: Title 24 Analysis Input File Name: Lot 9A Madison Club.ribdl9x ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 38.4 19.8 Proposed Design 37.7 8.4 0.7 11.4 RESULT: 3' COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 12.35 kWdc • Proposed PV kWh output exceeds proposed electricity use by 37% which may violate NEM rules. Contact local utility. ENERGY USE SUMMARY Energy Use (kTDV/ftz-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.8 5.44 -2.64 -94.3 Space Cooling 69.29 67.02 2.27 3.3 IAQ Ventilation 1.99 1.99 0 0 Water Heating 2.42 5.68 -3.26 -134.7 Self Utilization Credit n/a -5.26 5.26 n/a Compliance Energy Total 76.5 74.87 1.63 2.1 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Exception Module Type Array Type Power Electronics CFI Azimuth Tilt Array Angle Tilt: (x in 12) Inverter Eff. Annual Solar Access (kWdc) (deg) Input (deg) N (%) 20 NA Premium Fixed (r) f Microinverters false 180 Degrees 0 0 98 100 Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 3 of 17) ENERGY DESIGN RATING BATTERY INPUTS 01 02 03 04 05 06 Control Capacity (kWh) Charging Efficiency Rate (kW)Rate (kW) Discharging Efficiency Rate (kW)Rate (kW) Basic 20 0.95 n/a 0.95 n/a REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Battery System: 20 kWh (Self Utilization Credit taken) • Cool roof • Insulation above roof deck • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Building air leakage/reduced infiltration • Indoor air quality ventilation • Kitchen range hood Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity HVAC Distribution System Verifications: • Duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • Pipe Insulation, All Lines Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 4 of 17) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftz) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot 9A Project 9698 1 8 6 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 4 Conditioned HVAC System 41 1362 12 DHW Sys 1 N/A Zone 5 Conditioned HVAC System 52 1302 12 DHW Sys 1 N/A Zone 6 Conditioned HVAC System 63 1869 12 DHW Sys 1 N/A Zone 1 Conditioned HVAC System 14 1361 12 DHW Sys 1 N/A Zone 2 Conditioned HVAC System 25 2271 12 DHW Sys 1 N/A Zone 3 Conditioned HVAC System 36 1533 12 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Tilt (deg) Area (ft2) Northeast Exterior Wall Zone 4 R-21 Wall 45 Back 456 192 90 Southwest Exterior Zone 4 R-21 Wall 225 Front 660 212.515 90 Wall Northwest Exterior Zone 4 R-21 Wall 315 Left 360 72.6 90 Wall Northeast Exterior Wall Zone 5 R-21 Wall 45 Back 780 459 90 2 Southwest Exterior Zone 5 R-21 Wall 225 Front 780 36 90 Wall 2 Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 5 of 17) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Door Tilt (deg) Area (ft2) Northwest Exterior Zone 5 R-21 Wall 315 Left 532 196 90 Wall 2 Southeast Exterior Wall Zone 6 R-21 Wall 135 Right 616 100 90 Southwest Exterior Zone 6 R-21 Wall 225 Front 756 224 90 Wall 3 Northeast Exterior Wall Zone 1 R-21 Wall 45 Back 420 24 90 3 Southwest Exterior Zone 1 R-21 Wall 225 Front 420 216 90 Wall 4 Northwet Exterior Wall Zone 1 R-21 Wall 315 Left 686 132.99 90 Northeast Exterior Wall Zone 2 R-21 Wall 45 Back 110 21 90 4 Southwest Exterior Zone 2 R-21 Wall 225 Front 880 668 90 Wall 5 Northeast Exterior Wall Zone 3 R-21 Wall 45 Back 620 384 90 5 Southeast Exterior Wall Zone 3 R-21 Wall 135 Right 120 32 90 2 Roof Zone 4 R-38 HP Attic 38-21+6 n/a n/a 1362 n/a n/a Roof 2 Zone 5 R-38 HP Attic 38-21+6 n/a n/a 1302 n/a n/a Roof 3 Zone 6 R-38 HP Attic 38-21+6 n/a n/a 1869 n/a n/a Roof 4 Zone 1 R-38 HP Attic 38-21+6 n/a n/a 1361 n/a n/a Roof 5 Zone 2 R-38 HP Attic 38-21+6 n/a n/a 2271 n/a n/a Roof 6 Zone 3 R-38 HP Attic 38-21+6 n/a n/a 1533 n/a n/a Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 6 of 17) ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 4 Attic RoofZone 4 Unventilated 0 0.79 0.9 No Yes Attic Zone 5 Attic RoofZone 5 Unventilated 0 0.79 0.9 No Yes Attic Zone 6 Attic RoofZone 6 Unventilated 0 0.79 0.9 No Yes Attic Zone 1 Attic RoofZone 1 Unventilated 0 0.79 0.9 No Yes Attic Zone 2 Attic RoofZone 2 Unventilated 0 0.79 0.9 No Yes Attic Zone 3 Attic RoofZone 3 Unventilated 0 0.79 0.9 No Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window D-48 Window Northeast Exterior Wall Back 45 16 12 1 192 0.51 NFRC 0.23 NFRC Bug Screen Window W-09 Window Southwest Exterior Wall Front 225 1 12.5 0.31 NFRC 0.24 NFRC Bug Screen Window D-46 Window Southwest Exterior Wall Front 225 1 72 0.51 NFRC 0.23 NFRC Bug Screen Window D-49 Window Southwest Exterior Wall Front 225 10.7 12 0 121.0 0.51 NFRC 0.23 NFRC Bug Screen Window W-08 Window Northwest Exterior Wall Left 315 1 72.6 0.31 NFRC 0.24 NFRC Bug Screen Window D-41 Window Northeast Exterior Wall 2 Back 45 36 12 1 432 0.51 NFRC 0.23 NFRC Bug Screen Window W-10 Window Southwest Exterior Wall 2 Front 225 1 12 0.31 NFRC 0.24 NFRC Bug Screen Window W-11 Window Southwest Exterior Wall 2 Front 225 1 12 0.31 NFRC 0.24 NFRC Bug Screen Window W-12 Window Southwest Exterior Wall 2 Front 225 1 12 0.31 NFRC 0.24 NFRC Bug Screen Window D-51 Window Northwest Exterior Wall 2 Left 315 1 196 0.51 NFRC 0.23 NFRC Bug Screen Window D-31 Window Southeast Exterior Wall Right 135 7 10 1 70 0.51 NFRC 0.23 NFRC Bug Screen Window W-15 Window Southeast Exterior Wall Right 135 1 30 0.51 NFRC 0.23 NFRC Bug Screen Window W-13 Window Southwest Exterior Wall 3 Front 225 4 3 1 12 0.47 NFRC 0.19 NFRC Bug Screen Window W-14 Window Southwest Exterior Wall 3 Front 225 4 3 1 12 0.47 NFRC 0.19 NFRC Bug Screen Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 7 of 17) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window D-37 Window Southwest Exterior Wall 3 Front 225 10 10 1 100 0.51 NFRC 0.23 NFRC Bug Screen Window D-38 Window Southwest Exterior Wall 3 Front 225 10 10 1 100 0.51 NFRC 0.23 NFRC Bug Screen Window W-04 Window Northeast Exterior Wall 3 Back 45 1 24 0.31 NFRC 0.24 NFRC Bug Screen Window D-22 Window Southwest Exterior Wall 4 Front 225 1 216 0.51 NFRC 0.23 NFRC Bug Screen Window W-05 Window Northwet Exterior Wall Left 315 5 5.5 1 28 0.43 NFRC 0.19 NFRC Bug Screen Window W-06 Window Northwet Exterior Wall Left 315 5 3.5 1 18.01 0.47 NFRC 0.19 NFRC Bug Screen Window W-07 Window Northwet Exterior Wall Left 315 5 3 1 15 0.31 NFRC 0.24 NFRC Bug Screen Window D-21 Window Northwet Exterior Wall Left 315 6 7 1 71.99 0.51 NFRC 0.23 NFRC Bug Screen Window W-01 Window Northeast Exterior Wall 4 Back 45 1 21 0.31 NFRC 0.24 NFRC Bug Screen Window D-23 Window Southwest Exterior Wall 5 Front 225 36 12 1 432 0.51 NFRC 0.23 NFRC Bug Screen Window D-24 Window Southwest Exterior Wall 5 Front 225 17 12 1 204 0.51 NFRC 0.23 NFRC Bug Screen Window W-01 2 Window Northeast Exterior Wall 5 Back 45 1 21 0.31 NFRC 0.24 NFRC Bug Screen Window W-02 Window Northeast Exterior Wall 5 Back 45 1 21 0.47 NFRC 0.19 NFRC Bug Screen Window W-03 Window Northeast Exterior Wall 5 Back 45 1 15 0.47 NFRC 0.19 NFRC Bug Screen Window D-09 Window Northeast Exterior Wall 5 Back 45 10 10 1 100 0.51 NFRC 0.23 NFRC Bug Screen Window D-10 Window Northeast Exterior Wall 5 Back 45 10 10 1 100 0.51 NFRC 0.23 NFRC Bug Screen Window D-15 Window Northeast Exterior Wall 5 Back 45 10 1 10 1 100 0.51 NFRC 0.23 1 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ftz) U-factor Door D-53 Northeast Exterior Wall 2 27 0.5 Doo D-25 Southwest Exterior Wall 5 32 0.5 Door D-04 Northeast Exterior Wall 5 27 0.5 Door D-26 Southeast Exterior Wall 2 32 0.5 Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 8 of 17) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window D-48 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-49 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-41 12 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-31 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window W-13 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window W-14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-37 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-38 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window W-05 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window W-06 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window W-07 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-21 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-23 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-24 20 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-09 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 9 of 17) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Carpeted Fraction Heated Slab -on -Grade Zone 4 1362 40 None 100% No Slab -on -Grade 2 Zone 5 1302 30 None 100% No Slab -on -Grade 3 Zone 6 1869 70 None 100% No Slab -on -Grade 4 Zone 1 1361 30 None 100% No Slab -on -Grade 5 Zone 2 2271 60 None 100% No Slab -on -Grade 6 Zone 3 1533 10 None 100% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 4 Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R-38 None / R 6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 10 of 17) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 5 Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 6 Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R 38 None / R 6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 1 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 2 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 3 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R 38 None / R 6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 11 of 17) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity R-value Continuous U-factor Assembly Layers R-value R 38 HP Attic 38 21+6 Ceilings (below Wood Framed 2x12 @ 24 in. O. C. R-22 None /None 0.035 Cavity / Frame: R-22.0 / 2x12 attic) Ceiling Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 3879.2 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Pipe Insulation credit DHW Heater 1 (4) n/a None DHW Sys 1-hers dhw WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating # Tank Energy Input Rating Insulation Standby Loss 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Units Vol. Factor or or Pilot R-value or Recovery or Flow Rate Brand or Model Ambient Condition Type (gal) Efficiency (Int/Ext) Eff. DHW Heater 1 Gas Commercial 4 50 0.98 TE > 100 0 0.020000 n/a n/a n/a Storage kBtu/hr Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 12 of 17) WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1- 1/4 Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Distribution Required Verified Heating Cooling Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count HVAC System 41 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 1 Air Distribution Setback New NA 1 1 System 1 System 1 System 1 HVAC System 52 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 2 Air Distribution Setback New NA 1 1 System 2 System 2 System 2 HVAC System 63 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 3 Air Distribution Setback New NA 1 1 System 3 System 3 System 3 HVAC System 14 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 4 Air Distribution Setback New NA 1 1 System 4 System 4 System 4 HVAC System 25 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 5 Air Distribution Setback New NA 1 1 System 5 System 5 System 5 HVAC System 36 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 6 Air Distribution Setback New NA 1 1 System 6 System 6 System 6 Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 13 of 17) HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Heating Cooling Zonally Compressor Name System Type Number of Units HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Controlled Type Heat Pump System 1 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi- Heat Pump System speed 1-hers-htpump Heat Pump System 2 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi- Heat Pump System speed 2-hers-htpump Heat Pump System 3 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi- Heat Pump System speed 3-hers-htpump Heat Pump System 4 Central split HP 1 10.5 45000 42500 22 13 Not Zonal Multi- Heat Pump System speed 4-hers-htpump Heat Pump System 5 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi- Heat Pump System speed 5-hers-htpump Heat Pump System 6 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi- Heat Pump System speed 6-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 2-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 4-hers-htpump Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 14 of 17) HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes Yes Yes Yes 5-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 6-hers-htpump HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return puts Duct Leakage HERS Verification Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 System Duct 1-hers-dirt Air Air Distribution No Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 2 System Duct 2-hers-dirt Air Air Distribution No Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 3 System Duct 3-hers-dist Air Air Distribution No Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 4 System Duct 4-hers-dirt Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 5 System Duct 5-hers-dist Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 15 of 17) HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Leakage HERS Verification Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 6 System Duct 6-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design Ducts Handler Conditioned Space Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 1-hers-dist Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 2-hers-dirt Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 3-hers-dirt Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 4-hers-dirt Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 5-hers-dist Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 6-hers-dist Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 16 of 17) HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.28 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.3 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.23 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.28 HVAC Fan 4-hers-fan HVAC Fan 5 HVAC Fan 0.32 HVAC Fan 5-hers-fan HVAC Fan 6 HVAC Fan 0.32 HVAC Fan 6-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.28 HVAC Fan 2-hers-fan Required 0.3 HVAC Fan 3-hers-fan Required 0.23 HVAC Fan 4-hers-fan Required 0.28 HVAC Fan 5-hers-fan Required 0.32 HVAC Fan 6-hers-fan Required 0.32 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SIRE SFam IAQVentRpt 327 0.25 Default 0 n/a Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 9A Project Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-31T11:26:34-07:00 Input File Name: Lot 9A Madison Club.ribdl9x CF1R-PRF-01E (Page 17 of 17) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Butch White 3 ubcl v wvCtel Company: Signature Date: Breeze Air Conditioning LLC 03/31/2022 Address: CEA/ HERS Certification Identification (If applicable): 75-145 Street Charles Place City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Butch White 3 tktc1 v W 7�Wel Company: Date Signed: Breeze Air Conditioning LLC 03/31/2022 Address: License: 75-145 Street Charles Place 1045015 City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010045755A-000-000-0000000-0000 Registration Date/Time: 03/31/2022 11:34 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-03-31 11:28:41 Schema Version: rev 20200101