Loading...
BRES2021-0264 - Title 24CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 1 of 16) GENERAL INFORMATION 01 Project Name Lot 109B Residence Madison Club 02 Run Title Title 24 Analysis 03 Project Location 81-591 Baffin Avenue 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) 0 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 6 14 Addition Cond. Floor Area (ft2) 0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U-factor 0.46 18 Total Cond. Floor Area (ft) 7083 19 Glazing Percentage (%) 24.57% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available? I Yes VALID ONLY FOR NEW PERMIT APPLICATIONS THROUGH DECEMBER 31, 2021 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 01 /04/2023 'BY [ REVISION 3 INSTALLATION OF HVAC EQUIPMENT FOR AV ROOM. 2019 CALIFORNIA BUILDING CODES. Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name: Lot 109B Residence Madison Club Calculation Date/Time: 2022-09-28T12:05:17-07:00 (Page 2 of 16) Calculation Description: Title 24 Analysis Input File Name: Lot 109B Madison Club.ribdl9x ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency' (EDR) Total' (EDR) Efficiency' (EDR) Total' (EDR) Standard Design 39.7 20.2 Proposed Design 39.7 11.5 0 8.7 RESULT: 3' COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 10.01 kWdc • Proposed PV kWh output exceeds proposed electricity use by 30% which may violate NEM rules. Contact local utility. ENERGY USE SUMMARY Energy Use (kTDV/ftz-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.21 5 -1.79 -55.8 Space Cooling 75.23 73.82 1.41 1.9 IAQ Ventilation 1.85 1.85 0 0 Water Heating 3.32 2.82 0.5 15.1 Self Utilization Credit n/a 0 0 n/a Compliance Energy Total 83.61 83.49 0.12 0.1 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Azimuth Tilt Array Angle Inverter Eff. Annual (kWdc) Exception Module Type Array Type Power Electronics CFI (deg) Input (deg) Tilt: (x in 12) N Solar Access N 15 NA Premium Fixed (r) f Microinverters false 180 Degrees 0 0 99 100 Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis REQUIRED SPECIAL FEATURES Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Floor has high level of insulation • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY CF1R-PRF-01E (Page 3 of 16) The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Building air leakage/reduced infiltration • Indoor air quality ventilation • Kitchen range hood Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity HVAC Distribution System Verifications: • Duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Number of Bedrooms Number of Zones Number of Ventilation Number of Water Units Cooling Systems Heating Systems Lot 109E Residence Madison 7083 1 6 5 0 1 Club Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 4 of 16) ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 11 2735 12 DHW Sys 1 N/A Zone 2 Conditioned HVAC System 2A &2B 1368 12 DHW Sys 1 N/A Zone 4 Conditioned HVAC System 43 1834 12 DHW Sys 1 N/A Zone 5 Conditioned HVAC System 54 1116 12 DHW Sys 1 N/A Zone 6 Conditioned HVAC System 65 30 12 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Door Area (ft2) Tilt (deg) North Exterior Wall Zone 1 R-21 Wall 0 Front 504 287.5 90 South Exterior Wall Zone 1 R-21 Wall 180 Back 980 606 90 West Exterior Wall Zone 1 R-21 Wall 270 Right 378 60 90 East Exterior Wall Zone 2 R-21 Wall 90 Left 684 0 90 West Exterior Wall 2 Zone 2 R-21 Wall 270 Right 784 254 90 North Exterior Wall 2 Zone 2 R-21 Wall 0 Front 420 0 90 North Exterior Wall 3 Zone 4 R-21 Wall 0 Front 336 27 90 South Exterior Wall 2 Zone 4 R-21 Wall 180 Back 268 168 90 East Exterior Wall 2 Zone 4 R-21 Wall 90 Left 714 138.5 90 North Exterior Wall 4 Zone 5 R-21 Wall 0 Front 364 27 90 South Exterior Wall 3 Zone 5 R-21 Wall 180 Back 364 0 90 East Exterior Wall 3 Zone 5 R-21 Wall 90 Left 700 66 90 West Exterior Wall 3 Zone 5 R-21 Wall 270 Right 700 144 90 Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109B Madison Club.ribdl9x CF1R-PRF-01E (Page 5 of 16) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) North Exterior Wall 5 Zone 6 R-38 Wall -Batt 0 Front 50 0 90 South Exterior Wall 4 Zone 6 R-38 Wall -Batt 180 Back 50 0 90 East Exterior Wall 4 Zone 6 R-38 Wall -Batt 90 Left 54 0 90 West Exterior Wall 4 Zone 6 R-38 Wall -Batt 270 Right 54 21 90 Roof 2 Zone 1 R-38 HP Attic 38-21 n/a n/a 2735 n/a n/a Roof 3 Zone 2 R-38 HP Attic 38-21 n/a n/a 1368 n/a n/a Roof 4 Zone 4 R-38 HP Attic 38-21 n/a n/a 1818 n/a n/a Roof 5 Zone 5 R-38 HP Attic 38-21 n/a n/a 1116 n/a n/a Roof 6 Zone 6 R-38 HP Attic 38-21 n/a n/a 30 n/a n/a Raised Floor Zone 5 R-30 Floor Crawlspace n/a n/a 1116 n/a n/a OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 Skylight Area Roof Rise (x in Roof Name Zone Construction Azimuth Orientation Area (ft) z 12) Reflectance Roof Emittance Cool Roof (ft) R-38 HP Attic Roof Zone 4 0 Front 16.1 16 0.2 0.6 0.75 Yes 38-211 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Unventilated 0 0.6 0.75 No Yes Attic Zone 2 Attic RoofZone 2 Unventilated 0 0.6 0.75 No Yes Attic Zone 4 Attic RoofZone 4 Unventilated 0 0.6 0.75 No Yes Attic Zone 5 Attic RoofZone 5 Unventilated 0 0.6 0.75 No Yes Attic Zone 6 Attic RoofZone 6 Unventilated 0 0.6 0.75 No Yes Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 6 of 16) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft2) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading Window W-01 Window North Exterior Wall Front 0 5 11.5 1 57.5 0.31 NFRC 0.24 NFRC Bug Screen Window W-02 Window North Exterior Wall Front 0 5 11.5 1 57.5 0.31 NFRC 0.24 NFRC Bug Screen Window W-03 Window North Exterior Wall Front 0 5 11.5 1 57.5 0.31 NFRC 0.24 NFRC Bug Screen Window W-04 Window North Exterior Wall Front 0 5 11.5 1 57.5 0.31 NFRC 0.24 NFRC Bug Screen Window D-01 Window North Exterior Wall Front 0 5 11.5 1 57.5 0.43 NFRC 0.19 NFRC Bug Screen Window D-15 Window South Exterior Wall Back 180 26 12 1 312 0.51 NFRC 0.23 NFRC Bug Screen Window D-16 Window South Exterior Wall Back 180 24.5 12 1 294 0.51 NFRC 0.23 NFRC Bug Screen Window W-09 Window West Exterior Wall Right 270 1 20 0.31 NFRC 0.24 NFRC Bug Screen Window W-10 Window West Exterior Wall Right 270 1 20 0.34 NFRC 0.22 NFRC Bug Screen Window W-11 Window West Exterior Wall Right 270 1 20 0.31 NFRC 0.24 NFRC Bug Screen Window D-19 Window West Exterior Wall 2 Right 270 1 80 0.51 NFRC 0.23 NFRC Bug Screen Window D-210 Window West Exterior Wall 2 Right 270 1 80 0.51 NFRC 0.23 NFRC Bug Screen Window D-25 Window West Exterior Wall 2 Right 270 1 80 0.51 NFRC 0.23 NFRC Bug Screen WindowW-12 Window West Exterior Wall 2 Right 270 1 14 0.47 NFRC 0.19 NFRC Bug Screen Window D-14 Window South Exterior Wall 2 Back 180 14 12 1 168 0.51 NFRC 0.23 NFRC Bug Screen Window W-06 Window East Exterior Wall 2 Left 90 1 10 0.31 NFRC 0.24 NFRC Bug Screen Window W-07 Window East Exterior Wall 2 Left 90 1 15 0.31 NFRC 0.24 NFRC Bug Screen Window W-08 Window East Exterior Wall 2 Left 90 1 17.5 0.31 NFRC 0.24 NFRC Bug Screen Window D-13 Window East Exterior Wall 2 Left 90 1 48 0.51 NFRC 0.23 NFRC Bug Screen Window D-12 Window East Exterior Wall 2 Left 90 1 48 0.51 NFRC 0.23 NFRC Bug Screen Window W-201 Window East Exterior Wall 3 Left 90 1 50 0.41 NFRC 0.26 NFRC Bug Screen Window W-202 Window East Exterior Wall 3 Left 90 1 16 0.47 NFRC 0.19 NFRC Bug Screen Window D-203 Window West Exterior Wall 3 Right 270 1 72 0.51 NFRC 0.23 NFRC Bug Screen Window D-206 Window West Exterior Wall 3 Right 270 1 72 0.51 NFRC 0.23 NFRC Bug Screen Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109B Madison Club.ribdl9x CF1R-PRF-01E (Page 7 of 16) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Width Height Area U-factor SHGC Exterior Name Type Surface Orientation Azimuth (ft) (ft) Mult. (ft2) U-factor Source SHGC Sourc Shading a Skylight W-203 Skylight Roof Front 0 1 16 0.39 NFRC 0.29 NFRC None OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ftz) U-factor Door D-03 North Exterior Wall 3 27 0.5 Door D-201 North Exterior Wall 4 27 0.5 Door West Exterior Wall 4 21 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window W-01 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window W-02 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window W-03 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window W-04 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-01 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-15 16 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-14 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 8 of 16) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Carpeted Fraction Heated Slab -on -Grade Zone 1 2735 63 None 100% No Slab -on -Grade 2 Zone 2 1368 74 None 100% No Slab -on -Grade 3 Zone 4 1834 70 None 100% No Slab -on -Grade 4 Zone 6 30 14 None 80% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-38 Wall -Batt Exterior Walls Wood Framed Wall 2x12 @ 24 in. 0. C. R-38 None / None 0.037 Cavity / Frame: R-38 / 2x12 Exterior Finish: 3 Coat Stucco Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood R-38 HP Attic 38-211 Cathedral Ceilings Wood Framed 2x12 @ 24 in. 0. C. R-21 R-38 /None 0.017 Siding/sheathing/decking Ceiling Cavity / Frame: R-21 / 2x12 Sheathing / Insulation: R-38 Sheathing Inside Finish: Gypsum Board Inside Finish: Gypsum Board R-21 Walll Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109B Madison Club.ribdl9x CF1R-PRF-01E (Page 9 of 16) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZone 1 Attic Roofs 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZone 2 Attic Roofs 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZone 4 Attic Roofs 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZone 5 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZone 6 Attic Roofs 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Floor Surface: Carpeted R-30 Floor Crawlspace Floors Over Wood Framed Floor 2x10 @ 16 in. 0. C. R-25 None /None 0.038 Floor Deck: Wood Crawlspace Siding/sheathing/decking Cavity / Frame: R-25 / 2x10 Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109B Madison Club.ribdl9x CF1R-PRF-01E (Page 10 of 16) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value R 38 HP Attic 38 21 Ceilings (below Wood Framed 2x12 @ 24 in. O. C. R 21 None /None 0.035 Cavity / Frame: R-21.0 / 2x12 attic) Ceiling Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 2833.2 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (1) n/a None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating # Tank Energy Input Rating Insulation Standby Loss 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Units Vol. Factor or or Pilot R-value or Recovery or Flow Rate Brand or Model Ambient Condition Type (gal) Efficiency (Int/Ext) Eff. DHW Heater 1 Gas Commercial 1 75 0.82-TE > 85 0 0.002000 n/a n/a n/a Storage kBtu/hr Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 11 of 16) WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Distribution Required Verified Heating Cooling Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count HVAC System 11 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 1 Air Distribution Setback New NA 2 2 System 1 System 1 System 1 HVAC System 2A &2B &32 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 2 Air Distribution Setback New NA 1 1 System 2 System 2 System 2 HVAC System 43 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 3 Air Distribution Setback New NA 1 1 System 3 System 3 System 3 HVAC System 54 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 4 Air Distribution Setback New NA 1 1 System 4 System 4 System 4 HVAC System 65 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 5 Air Distribution Setback New NA 1 1 System 5 System 5 System 5 Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 12 of 16) HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 Central split HP 2 10 50500 47900 19 12.7 Not Zonal Multi- Heat Pump System speed 1-hers-htpump Heat Pump System 2 Central split HP 1 8.2 66000 43000 14 10.9 Not Zonal Multi- Heat Pump System speed 2-hers-htpump Heat Pump System 3 Central split HP 1 10 50500 47900 19 12.7 Not Zonal Multi- Heat Pump System speed 3-hers-htpump Heat Pump System 4 Central split HP 1 10 45500 34400 18 12.5 Not Zonal Multi- Heat Pump System speed 4-hers-htpump Heat Pump System 5 Central split HP 1 12 10600 7600 21.5 12.5 Not Zonal Single Heat Pump System Speed 5-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Required 350 Not Required Not Required No No Yes Yes 2-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Required 350 Required Required No Yes Yes Yes 4-hers-htpump Heat Pump System Required 350 Required Required No Yes Yes Yes 5-hers-htpump Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 13 of 16) HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return BypasDucts Duct Leakage HERS Verification Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 System Duct 1-hers-d ist Air Air Distribution NO Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 2 Tested System Duct 2-hers-dist Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 3 System Duct 3-hers-dist Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 4 System Duct 4-hers-dist Air Air Distribution NO Sealed and Distribution Unconditioned attic Non Verified R 8 R 8 Attic Attic n/a n/a Bypass System 5 Tested System Duct 5-hers-dist Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 14 of 16) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design g n Ducts Handler Conditioned Space Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 1-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 2-hers-dist Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 3-hers-dist Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 4-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 5-hers-dist HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.3 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.21 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.3 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.27 HVAC Fan 4-hers-fan HVAC Fan 5 HVAC Fan 0.58 HVAC Fan 5-hers-fan Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109E Madison Club.ribdl9x CF1R-PRF-01E (Page 15 of 16) HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.3 HVAC Fan 2-hers-fan Required 0.21 HVAC Fan 3-hers-fan Required 0.3 HVAC Fan 4-hers-fan Required 0.27 HVAC Fan 5-hers-fan Required 0.58 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness SRE SFam IAQVentRpt 223 0.25 Default 0 n/a Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 109E Residence Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-09-28T12:05:17-07:00 Input File Name: Lot 109B Madison Club.ribdl9x CF1R-PRF-01E (Page 16 of 16) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Butch White 13 [rT.t v W hWe,- Company: Signature Date: Breeze Air Conditioning LLC 09/28/2022 Address: CEA/ HERS Certification Identification (If applicable): 75-145 Street Charles Place City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Butch White '� j atck Whig Company: Date Signed: Breeze Air Conditioning LLC 09/28/2022 Address: License: 75-145 Street Charles Place 1045015 City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010153018A-000-000-0000000-0000 Registration Date/Time: 09/28/2022 12:03 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-09-28 12:07:14 Schema Version: rev 20200101