Loading...
BRES2021-0410- Title 24CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 1 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 GENERAL INFORMATION 01 Project Name Lot 66 Madison Club 02 Run Title Title 24 Analysis 03 Project Location 81-370 Peary Place 04 City La Quinta 05 Standards Version 2019 06 Zip code 92260 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)180 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 6 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.46 18 Total Cond. Floor Area (ft2)9391 19 Glazing Percentage (%)20.85% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 2 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 37.9 20 Proposed Design 36.8 16.9 1.1 3.1 RESULT:3:COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 12.90 kWdc •Proposed PV kWh output exceeds proposed electricity use by 1.5% which may violate NEM rules. Contact local utility. ENERGY USE SUMMARY Energy Use (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.81 8.54 -3.73 -77.5 Space Cooling 79.97 70.73 9.24 11.6 IAQ Ventilation 1.93 1.93 0 0 Water Heating 2.51 5.2 -2.69 -107.2 Self Utilization Credit n/a 0 0 n/a Compliance Energy Total 89.22 86.4 2.82 3.2 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg)Tilt: (x in 12)Inverter Eff. (%) Annual Solar Access (%) 15 NA Premium Fixed (roof mount)Microinverters false 180 Degre es 0 0 98 100 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 3 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Cool roof •Insulation above roof deck •Insulation below roof deck •Window overhangs and/or fins •Non-standard duct location (any location other than attic) HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •Verified HSPF •Verified heat pump rated heating capacity HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot 66 Madison Club 9391 1 6 6 0 1 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 4 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 11 1420 8 DHW Sys 1 N/A Zone 2 Conditioned HVAC System 22 1883 8 DHW Sys 1 N/A Zone 3 Conditioned HVAC System 33 1688 8 DHW Sys 1 N/A Zone 4 Conditioned HVAC System 44 1853 8 DHW Sys 1 N/A Zone 5 Conditioned HVAC System 55 1435 10 DHW Sys 1 N/A Zone 6 Conditioned HVAC System 66 1112 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) North Exterior Wall Zone 1 R-21 Wall 0 Back 770 501.84 90 East Exterior Wall Zone 1 R-21 Wall 90 Right 442 37.5 90 South Exterior Wall Zone 2 R-21 Wall 180 Front 800 120 90 East Exterior Wall 2 Zone 2 R-21 Wall 90 Right 200 120 90 North Exterior Wall 2 Zone 2 R-21 Wall 0 Back 240 24 90 West Exterior Wall Zone 2 R-21 Wall 315 n/a 216 45 90 North Exterior Wall 3 Zone 3 R-21 Wall 0 Back 4100 180 90 East Exterior Wall 3 Zone 3 R-21 Wall 90 Right 238 0 90 West Exterior Wall 2 Zone 3 R-21 Wall 270 Left 910 181 90 South Exterior Wall 2 Zone 4 R-21 Wall 180 Front 406 79 90 East Exterior Wall 4 Zone 4 R-21 Wall 90 Right 1040 250 90 West Exterior Wall 3 Zone 4 R-21 Wall 0 Back 1040 195 90 South Exterior Wall 3 Zone 5 R-21 Wall 180 Front 476 0 90 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 5 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) East Exterior Wall 5 Zone 5 R-21 Wall 90 Right 336 17.5 90 West Exterior Wall 4 Zone 5 R-21 Wall 270 Left 336 108 90 North Exterior Wall 4 Zone 6 R-21 Wall 0 Back 476 27 90 East Exterior Wall 6 Zone 6 R-21 Wall 0 Back 644 0 90 West Exterior Wall 5 Zone 6 R-21 Wall 270 Left 644 166 90 Roof 3 Zone 1 R-30 Roof Attic 6+30 n/a n/a 1420 n/a n/a Roof 4 Zone 2 R-30 Roof Attic 6+30 n/a n/a 1883 n/a n/a Roof 5 Zone 3 R-30 Roof Attic 6+30 n/a n/a 1688 n/a n/a Roof 6 Zone 4 R-30 Roof Attic 6+30 n/a n/a 1853 n/a n/a Roof 7 Zone 5 R-30 Roof Attic 6+30 n/a n/a 1419 n/a n/a Roof 8 Zone 6 R-30 Roof Attic 6+30 n/a n/a 1096 n/a n/a Raised Floor Zone 5 R-19 Floor Crawlspace n/a n/a 1435 n/a n/a Raised Floor 2 Zone 6 R-19 Floor Crawlspace n/a n/a 1112 n/a n/a OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Zone 5 R-30 Roof Attic 6+301 180 Back 16.1 16 0.2 0.79 0.9 Yes Roof 2 Zone 6 R-30 Roof Attic 6+301 180 Back 16.1 16 0.2 0.79 0.9 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Unventilated 0 0.79 0.9 No Yes 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 6 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 2 Attic RoofZone 2 Unventilated 0 0.79 0.9 No Yes Attic Zone 3 Attic RoofZone 3 Unventilated 0 0.79 0.9 No Yes Attic Zone 4 Attic RoofZone 4 Unventilated 0 0.79 0.9 No Yes Attic Zone 5 Attic RoofZone 5 Unventilated 0 0.79 0.9 No Yes Attic Zone 6 Attic RoofZone 6 Unventilated 0 0.79 0.9 No Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window D-13 Window North Exterior Wall Back 0 6 12 1 72 0.51 NFRC 0.23 NFRC Bug Screen Window D-14 Window North Exterior Wall Back 0 36 12 0 429.8 4 0.51 NFRC 0.23 NFRC Bug Screen Window W-05 Window East Exterior Wall Right 90 1 12.5 0.31 NFRC 0.24 NFRC Bug Screen Window W-06 Window East Exterior Wall Right 90 1 12.5 0.31 NFRC 0.24 NFRC Bug Screen Window W-07 Window East Exterior Wall Right 90 1 12.5 0.31 NFRC 0.24 NFRC Bug Screen Window D-01 Window South Exterior Wall Front 180 6 12 1 72 0.43 NFRC 0.19 NFRC Bug Screen Window D-12 Window East Exterior Wall 2 Right 90 10 12 1 120 0.51 NFRC 0.23 NFRC Bug Screen Window W-10 Window West Exterior Wall 315 1 18 0.31 NFRC 0.24 NFRC Bug Screen Window D-15 Window North Exterior Wall 3 Back 0 15 12 1 180 0.51 NFRC 0.23 NFRC Bug Screen Window W-08 Window West Exterior Wall 2 Left 270 1 9 0.47 NFRC 0.19 NFRC Bug Screen Window W-09 Window West Exterior Wall 2 Left 270 1 28 0.31 NFRC 0.24 NFRC Bug Screen Window D-16 Window West Exterior Wall 2 Left 270 1 72 0.51 NFRC 0.23 NFRC Bug Screen Window D-21 Window West Exterior Wall 2 Left 270 1 72 0.31 NFRC 0.24 NFRC Bug Screen Window W-03 Window South Exterior Wall 2 Front 180 1 52 0.31 NFRC 0.24 NFRC Bug Screen Window W-04 Window South Exterior Wall 2 Front 180 1 27 0.31 NFRC 0.24 NFRC Bug Screen 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 7 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window D-05 Window East Exterior Wall 4 Right 90 7 10 1 70 0.51 NFRC 0.23 NFRC Bug Screen Window D-06 Window East Exterior Wall 4 Right 90 9 10 1 90 0.51 NFRC 0.23 NFRC Bug Screen Window D-11 Window East Exterior Wall 4 Right 90 9 10 1 90 0.51 NFRC 0.23 NFRC Bug Screen Window W-12 Window West Exterior Wall 3 Back 0 6.5 10 1 65 0.31 NFRC 0.24 NFRC Bug Screen Window W-13 Window West Exterior Wall 3 Back 0 6.5 10 1 65 0.31 NFRC 0.24 NFRC Bug Screen Window W-14 Window West Exterior Wall 3 Back 0 6.5 10 1 65 0.31 NFRC 0.24 NFRC Bug Screen Window W-201 Window East Exterior Wall 5 Right 90 1 17.5 0.31 NFRC 0.24 NFRC Bug Screen Window D-205 Window West Exterior Wall 4 Left 270 1 108 0.51 NFRC 0.23 NFRC Bug Screen Window W-202 Window West Exterior Wall 5 Left 270 1 44 0.41 NFRC 0.22 NFRC Bug Screen Window W-203 Window West Exterior Wall 5 Left 270 1 14 0.51 NFRC 0.23 NFRC Bug Screen Window D-204 Window West Exterior Wall 5 Left 270 1 108 0.51 NFRC 0.23 NFRC Bug Screen Skylight W-302 Skylight Roof Back 0 1 16 0.39 NFRC 0.29 NFRC None Skylight W-301 Skylight Roof 2 Back 0 1 16 0.39 NFRC 0.29 NFRC None OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door D-26 South Exterior Wall 24 0.5 Door D-27 South Exterior Wall 24 0.5 Door D-24 North Exterior Wall 2 24 0.5 Door D-25 West Exterior Wall 27 0.5 Door D-201 North Exterior Wall 4 27 0.5 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 8 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window D-13 20 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-14 20 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-01 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-12 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-15 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-05 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-06 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window W-12 14 0.1 10 10 0 0 0 0 0 0 0 0 0 Window W-13 14 0.1 10 10 0 0 0 0 0 0 0 0 0 Window W-14 14 0.1 10 10 0 0 0 0 0 0 0 0 0 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Zone 1 1420 30 None 100%No Slab-on-Grade 2 Zone 2 1883 10 None 100%No Slab-on-Grade 3 Zone 3 1688 40 None 100%No 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 9 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade 4 Zone 4 1853 140 None 100%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco R-30 Roof Attic 6+301 Cathedral Ceilings Wood Framed Ceiling 2x12 @ 24 in. O. C.R-0 R-30 / R-6 0.026 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x12 Sheathing / Insulation: R-30 Sheathing Inside Finish: Gypsum Board R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic RoofZone 1 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 10 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofZone 2 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 3 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 4 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 5 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 6 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 11 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-19 Floor Crawlspace Floors Over Crawlspace Wood Framed Floor 2x6 @ 16 in. O. C.R-19 None / None 0.05 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6 R-30 Roof Attic 6+30 Ceilings (below attic) Wood Framed Ceiling 2x12 @ 24 in. O. C.R-0 None / None 0.474 Cavity / Frame: no insul. / 2x12 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2)n/a None n/a 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 12 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Commercial Storage 2 75 0.81-TE > 85 kBtu/hr 0 0.020000 n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System 11 Heat pump heating cooling Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 HVAC System 22 Heat pump heating cooling Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 Setback New NA 1 1 HVAC System 33 Heat pump heating cooling Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 Setback New NA 2 2 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 13 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System 44 Heat pump heating cooling Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 Setback New NA 4 4 HVAC System 55 Heat pump heating cooling Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution System 5 Setback New NA 1 1 HVAC System 66 Heat pump heating cooling Heat Pump System 6 Heat Pump System 6 HVAC Fan 6 Air Distribution System 6 Setback New NA 1 1 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi- speed Heat Pump System 1-hers-htpump Heat Pump System 2 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi- speed Heat Pump System 2-hers-htpump Heat Pump System 3 Central split HP 2 10.5 34600 32600 21 13 Not Zonal Multi- speed Heat Pump System 3-hers-htpump Heat Pump System 4 Central split HP 4 10 27600 26200 18.6 12.5 Not Zonal Multi- speed Heat Pump System 4-hers-htpump Heat Pump System 5 Central split HP 1 10.5 34600 32600 21 13 Not Zonal Multi- speed Heat Pump System 5-hers-htpump 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 14 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 6 Central split HP 1 10.5 34600 32600 21 13 Not Zonal Multi- speed Heat Pump System 6-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Verified HSPF Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 2-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 3-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 4-hers-htpump Required 350 Required Required No Yes Yes Yes Heat Pump System 5-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 6-hers-htpump Required 350 Required Required Yes Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Outdoor locations Non-Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 1-hers-dist 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 15 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 2 Outdoor locations Non-Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 2-hers-dist Air Distribution System 3 Outdoor locations Non-Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 3-hers-dist Air Distribution System 4 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Sealed and Tested Air Distribution System 4-hers-dist Air Distribution System 5 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 5-hers-dist Air Distribution System 6 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 6-hers-dist 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 16 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 3.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 2-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 3-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 4-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No Air Distribution System 5-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 6-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.31 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.31 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.22 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.18 HVAC Fan 4-hers-fan HVAC Fan 5 HVAC Fan 0.24 HVAC Fan 5-hers-fan 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 17 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 6 HVAC Fan 0.28 HVAC Fan 6-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.31 HVAC Fan 2-hers-fan Required 0.31 HVAC Fan 3-hers-fan Required 0.22 HVAC Fan 4-hers-fan Required 0.18 HVAC Fan 5-hers-fan Required 0.24 HVAC Fan 6-hers-fan Required 0.28 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 308 0.25 Default 0 n/a 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 66 Madison Club Calculation Date/Time:2022-02-15T07:24:18-08:00 (Page 18 of 18) Calculation Description:Title 24 Analysis Input File Name:Lot 66 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2022-02-15   07:26:17 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Butch White Breeze Air Conditioning LLC 02/15/2022 75-145 Street Charles Place Palm Desert, CA 92211 (760) 346-0855 Butch White Breeze Air Conditioning LLC 02/15/2022 75-145 Street Charles Place 1045015 Palm Desert, CA 92211 (760) 346-0855 422-P010021377A-000-000-0000000-0000 02/15/2022 07:25 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-E01058A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 1 of 6) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. The signer agrees that all applicable Mandatory Measures were met. Temporary labels are not to be removed before verification by the building inspector. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 2 of 6) Registration Number: 422-P010021377A-000-001-E01058A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 A. Fenestration/ Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft 2 glass in door, it is assumed to meet the minimum required U-factor (0.30) and SHGC (0.23).      If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).      Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products. 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacturer/ Brand Fenestration Area (ft2)Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/Sp ecial Features Window D-13 owens 72.0000 0 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window D-14 owens 429.8400 0 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window W-05 owens 12.5000 90 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window W-06 owens 12.5000 90 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window W-07 owens 12.5000 90 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window D-01 owens 72.0000 180 No 0.43 NFRC 0.19 NFRC Window Standard bug screens Window D-12 owens 120.0000 90 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window W-10 owens 18.0000 315 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window D-15 owens 180.0000 0 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window W-08 owens 9.0000 270 No 0.47 NFRC 0.19 NFRC Window Standard bug screens NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 3 of 6) Registration Number: 422-P010021377A-000-001-E01058A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 A. Fenestration/ Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft 2 glass in door, it is assumed to meet the minimum required U-factor (0.30) and SHGC (0.23).      If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).      Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products. 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacturer/ Brand Fenestration Area (ft2)Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/Sp ecial Features Window W-09 owens 28.0000 270 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window D-16 owens 72.0000 270 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window D-21 owens 72.0000 270 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window W-03 owens 52.0000 180 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window W-04 owens 27.0000 180 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window D-05 owens 70.0000 90 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window D-06 owens 90.0000 90 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window D-11 owens 90.0000 90 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window W-12 owens 65.0000 0 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window W-13 owens 65.0000 0 No 0.31 NFRC 0.24 NFRC Window Standard bug screens NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 4 of 6) Registration Number: 422-P010021377A-000-001-E01058A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 A. Fenestration/ Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft 2 glass in door, it is assumed to meet the minimum required U-factor (0.30) and SHGC (0.23).      If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).      Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products. 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacturer/ Brand Fenestration Area (ft2)Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/Sp ecial Features Window W-14 owens 65.0000 0 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window W-201 owens 17.5000 90 No 0.31 NFRC 0.24 NFRC Window Standard bug screens Window D-205 owens 108.0000 270 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window W-202 owens 44.0000 270 No 0.41 NFRC 0.22 NFRC Window Standard bug screens Window W-203 owens 14.0000 270 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Window D-204 owens 108.0000 270 No 0.51 NFRC 0.23 NFRC Window Standard bug screens Skylight W-302 owens 16.0000 0 No 0.39 NFRC 0.29 NFRC Skylight None Skylight W-301 owens 16.0000 0 No 0.39 NFRC 0.29 NFRC Skylight None B. Fenestration Installation 01 The U-factor of the installed windows for new construction and existing buildings must be equal to or less than those listed on the CF1R. 02 The SHGC of the installed windows for new construction and existing buildings must be equal to or less than those listed on the CF1R in climate zones 2, 4 and 8-15. For climate zones 1, 3, 5 and 16 there is no SHGC requirement. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 5 of 6) Registration Number: 422-P010021377A-000-001-E01058A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 B. Fenestration Installation 03 Temporary labels are not to be removed until verified by the building inspector. 04 The fenestration product manufacturer's installation specifications shall be followed when installing these products. The space between the fenestration product and rough opening shall be completely filled with insulation. If batt insulation is used, it is cut to size and placed properly around the fenestration product. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 6 of 6) Registration Number: 422-P010021377A-000-001-E01058A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 1 of 8) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 Medium and light density SPF manufacturers claim various R-values per inch. In California the maximum R-value that can be claimed for ccSPF is an R-value of 5.8 per inch and for ocSPF is an R-value of 3.6 per inch unless documentation is provided showing that the product and/or manufacturer has a current ICC Evaluation Service Report (ESR) that shows compliance with Acceptance Criteria for Spray-Applied Foam Plastic Insulation (AC-377). Note:The Energy Standards Section 110.7 requires that 'all joints, penetrations and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, weather stripped, or otherwise sealed to limit infiltration and exfiltration.' In areas where spray foam (SPF) insulation is used, the SPF can be considered the air barrier. Other than rigid board insulation, all other forms of insulation are not considered as an air barrier. A. Roof/Ceiling Insulation 01 02 03 04 05 06 07 08 09 10 I.D.Manufacturer and Brand Assembly/Framin g Material Assembly Thickness (inches) Framing Size and Spacing Insulation Type ESR Number Core/Cavity Insulation R-value Insulation Depth (inches) Continuous Insulation R-value R-30 Roof Attic 6+30 ownens Wood Framed Ceiling 11.75 2x12 24InchOC Fiberglass n/a 0 n/a 0 R-30 Roof Attic 6+301 ownens Wood Framed Ceiling 14.45 2x12 24InchOC Fiberglass n/a 0 n/a 6 Attic RoofZone 1 ownens Wood Framed Ceiling 9.78 2x4 24InchOC Fiberglass n/a 30 n/a 6 Attic RoofZone 2 ownens Wood Framed Ceiling 9.78 2x4 24InchOC Fiberglass n/a 30 n/a 6 Attic RoofZone 3 ownens Wood Framed Ceiling 9.78 2x4 24InchOC Fiberglass n/a 30 n/a 6 Attic RoofZone 4 ownens Wood Framed Ceiling 9.78 2x4 24InchOC Fiberglass n/a 30 n/a 6 Attic RoofZone 5 ownens Wood Framed Ceiling 9.78 2x4 24InchOC Fiberglass n/a 30 n/a 6 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 2 of 8) Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 A. Roof/Ceiling Insulation 01 02 03 04 05 06 07 08 09 10 I.D.Manufacturer and Brand Assembly/Framin g Material Assembly Thickness (inches) Framing Size and Spacing Insulation Type ESR Number Core/Cavity Insulation R-value Insulation Depth (inches) Continuous Insulation R-value Attic RoofZone 6 ownens Wood Framed Ceiling 9.78 2x4 24InchOC Fiberglass n/a 30 n/a 6 B. Wall Insulation 01 02 03 04 05 06 07 08 09 10 I.D.Manufacturer and Brand Assembly/Framin g Material Assembly Thickness (inches) Framing Size and Spacing Insulation Type ESR Number Core/Cavity Insulation R-value Insulation Depth (inches) Continuous Insulation R-value R-21 Wall owens Wood Framed Walls 6.88 2x6 16InchOC Fiberglass n/a 21 n/a 0 C. Mass Insulation This section does not apply to this project. D. Raised Floor Insulation 01 02 03 04 05 06 07 08 09 I.D.Manufacturer and Brand Framing Material Framing Size and Spacing Insulation Type ESR Number Cavity Insulation R-value Insulation Depth (inches) Exterior Floor Insulation R-value R-19 Floor Crawlspace Wood framed floor 2x6 16InchOC Fiberglass n/a 19 n/a 0 E. Slab Floor/Perimeter Insulation (See Section F. For Insulation Requirements For Heated Slabs) This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 3 of 8) Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 F. Heated Slabs Insulation 01 All heated slabs shall be insulated as required by Section 110.8(g). Footings must meet required insulation levels. 02 Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-15 require R-5, and climate zone 16 requires R-10. 03 Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires R-10 vertical and R-7 horizontal. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Minimum Mandatory Measures 01 Insulation - 110.8(a): All installed Insulation is certified and listed with Department of Consumer Affairs, "Standards for Insulating Material". 02 Insulation - 110.8(b): Urea formaldehyde foam insulation is protected by 4 mil polyethylene vapor retarder. 03 Insulation - 110.8(c): Flame spread and smoke density requirements of CBC are met. 04 Raised Floor - 150.0(d): All raised wood-frame floor have a minimum R-19 insulation or equivalent U-factor 05 Slab Floor/Perimeter - 150.0(l): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and is protected from physical damage and UV light deterioration. 06 Above Grade Exterior Wall - 150.0(c)1 and 150.1(c)6: All 2x4 wood-frame walls have a minimum R-13 insulation or equivalent U-factor not exceeding U-0.102. 07 Above Grade Exterior Wall - 150.0(c)2 and 150.1(c)6: All 2x6 wood-frame walls have a minimum R-20 insulation or equivalent U-factor not exceeding U-0.071. 08 Ceiling/Rafter Roof - 150.0(a)1: All wood-frame ceiling have a minimum R-22 insulation or equivalent U-factor. 09 Vapor Retarder - 150(g)1: In Climate Zones 1 through 16, the earth floor of unvented crawl space shall be covered with a Class I or Class II vapor retarder. This requirement shall also apply to controlled ventilation crawl space for buildings complying with the Exception to Section 150.0(d). 10 Vapor Retarder - 150(g)2: In Climate Zones 14 and 16, a Class I or Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air-permeable insulation. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 4 of 8) Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 G. Minimum Mandatory Measures 11 Heated Slabs - 110.8(g): All heated slabs shall be insulated as required. •Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-5 require R-5, and climate zone 16 requires R-10. •Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires R-10 vertical and R-7 horizontal. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. H. Installed Insulation 01 Installed insulation R-values are the same or greater than listed on the CF1R. 02 No gaps or voids between the insulation and framing. 03 No gaps between the sides or ends of batt insulation. 04 Loose-fill insulation must be installed to the minimum installed weight per square foot (density) of the manufacturer's cut sheet for the proposed R-value. 05 Batt insulation is not compressed (no stuffing of the insulation into the cavity) and is installed to its full thickness. 06 Insulation is cut around obstructions such as electrical boxes. 07 Batt insulation is delaminated around all plumbing and electrical lines in ceilings, walls and floors. 08 Band joists are insulated to the same R-value as the wall. 09 In all narrow cavities the insulation shall be cut to fit or filled with expanding foam. 10 Insulation was installed per manufacturer instructions. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. I. Wall Insulation 01 When allowed by manufacturer, low expanding foam shall be used to fill gaps and voids around windows and doors. If not, the cavity must be air tight and filled completely with insulation. Batt insulation must be cut to width. No stuffing allowed. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 5 of 8) Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 I. Wall Insulation 02 Install wall insulation before installing tubs, showers and fireplaces. 03 Electric panels on walls separating conditioned and unconditioned space are sealed and insulated behind the panel with rigid insulation or expanding foam. 04 All walls of interior closets vented to the outside for HVAC or water heating equipment have the same R-value and air barrier as the exterior walls and ceiling. Doors are insulated and weather stripped. 05 Ducting not allowed in exterior walls unless insulated to R6 or greater and the insulation and duct are not crushed. Ducting not allowed in 2x4 wall assemblies. 06 Corner channels, wall intersections, and double sided shear walls insulated to the required R-value before enclosing the wall. 07 Insulation that does not fill the cavity placed against exterior air barrier. 08 Band joists are insulated to the same R-value as the walls. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. J. Ceiling Roof Insulation 01 Insulation extends to the outside edge of the exterior top plates and is flush against any ventilation dams/baffles. 02 Insulation is in direct contact with ceiling, so there are no gaps between the ceiling and the insulation. 03 For chimneys and flues, the insulation is in contact with the sheet metal collar. 04 Can lights are covered with insulation to the same depth as required by the CF1R for ceiling insulation. If not an area weighted calculation is required to be turned in with this compliance document. 05 Walkways and mechanical platforms insulated to the same R-value as required for the ceiling. If not an area weighted calculation is required to be turned in with this compliance document. 06 Insulate soffits by adding an air barrier and cover with insulation, or insulate the entire soffit including floor and walls. 07 Knee walls and skylight shafts are insulated to the wall R-value and in full contact with the interior air barrier. If framing on these surfaces is laid flat batt insulation is cut to fit around the framing. Batt insulation is not allowed to be draped over the framing. 08 Attic access doors insulated to the same R-value as ceiling. The insulation is permanently attached using adhesive or mechanical fasteners. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 6 of 8) Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 J. Ceiling Roof Insulation 09 Attic access must be surrounded with a dam at least the same depth as the insulation to prevent loss of ceiling insulation. 10 Batt insulation cut to fit around cross bracings and truss webs in attic. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. K. Raised Floor Insulation 01 Insulation in full contact with subfloor. 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 04 If the basement is conditioned the walls adjacent to the crawlspace must meet minimum wall R-value requirements. This includes framed stem walls, and vertical concrete retaining walls. 05 If access to the crawl space is from the conditioned area, the raised floor must have an airtight insulated access hatch. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. L. Floor Above Garage Insulation 01 Insulation must be in full contact with subfloor if the air barrier is at the band joist at the garage/house wall. 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 04 If air barrier is at the perimeter of the garage, below conditioned subfloor, the insulation is placed on the garage ceiling. The perimeter of subfloor is also insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 7 of 8) Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 M. Cantilevered Floor Insulation 01 Insulation in full contact with cantilevered subfloor. Insulation hangers spaced at 18 inches or less, insulation hangers do not compress insulation. 02 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 03 Sealed blocking is installed between joists where wall rim joist would be located in the absence of a cantilever. Insulation is placed on both sides of this block. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. N. Attached Porch Roof Insulation 01 The exterior insulated wall at the intersection with the porch roof is fully insulated above, below and behind the roof line. 02 Where truss framing is used, airtight blocking is at the top and bottom of each wall/roof section and insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 8 of 8) Registration Number: 422-P010021377A-000-001-E03059A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-E04060A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. General Information 01 Construction Type Attic 02 Total Attic Area (ft2)2000 03 Radiant Barrier Installed?Yes 04 Attic Space Ventilated or Unventilated?Ventilated 05 Minimum Ventilation Method of Compliance 1/150 Note: in order to comply with the 1/300 exception, a Class I or II vapor retarder is required to be installed in climate zone 14 and 16. B. Radiant Barrier 01 Brand Name and product number 02 Installation Type Attached between truss/rafters, stapled to each side C. Schedule of Lower Vents The Net Free Area (NFA) of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non-manufactured products, assume that the net free area is one third of the total aperture area. 01 02 03 04 Type of Vent For instance, eyebrow vent, eave vent, round vent NFA per vent (in2) (Manufacturer's Specification Sheet)Number of Vents Installed Total NFA Per Vent Type (in2) Other 100 10 1000 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 2 of 5) Registration Number: 422-P010021377A-000-001-E04060A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 D. Schedule of Upper Vents The Net Free Area of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non-manufactured products, assume that the net free area is one third of the total aperture area. 01 02 03 04 Type of Vent (For instance, eyebrow vent, eave vent, round vent, ridge vent) NFA per vent (in2)/Per Linear Foot (Manufacturer's Specification Sheet)Number of Vents/Linear Feet Installed Total NFA Per Vent Type (in2) Other 100 10 1000 E. Required Vent Area 01 Combined NFA of installed upper and lower vents (in2)2000 02 Minimum required combined NFA of upper and lower vents (in2)960 03 NFA of installed upper vents (in2)1000 04 Minimum required NFA of upper vents (in2)288 05 Compliance Statement Building complies F. Radiant Barrier - Additional Requirements Radiant Barrier 01 Radiant barrier must be installed on all vertical surfaces in the attic including gable ends. 02 The emittance of the radiant barrier shall be less than or equal to 0.05 as tested with ASTM C1371, or E408. 03 The product shall meet all requirements for California certified insulation materials (radiant barriers) of the Department of Consumer Affairs, Bureau of Electronic and Appliance Repair, Home Furnishings and Thermal Insulation, as specified by CCR, Title 24, Part 12, Chapter 12-13, Standards for Insulating Material 04 When determining the Total Attic Area, the area over unconditioned spaces such as the garage is included when the attic spaces are connected NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 3 of 5) Registration Number: 422-P010021377A-000-001-E04060A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 G. Attic Ventilation - Additional Requirements Lower Vents 01 Lower vents are within one foot of the eave. Upper Vents 02 Upper vents are within three feet of the ridge. Vent Area 03 The NFA of upper vents must be within required NFA range of upper vents Note: per Exception to R806.2 of the CBC Title 24, Part2, Vol.2.5, if the net free ventilating area is less than 1:150, then the upper ventilation must be at least 40% and no more than 50%. Part 2 contains additional requirements that must be met if the area is less than 1:150. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. H. Roofing Products (Cool Roof) Installation Information 01 02 03 04 05 06 07 08 09 10 11 12 Tag/ID Roof Pitch CRRC Product ID Number Product type CRRC Listed Aged Solar Reflectance Installed Required Initial Solar Reflectance Aged Solar Reflectance Thermal Emittance SRI Aged Solar Reflectance Thermal Emittance SRI Attic Zone 1 Roof pitch is >= 2 :12 Clay roof tiles Yes .79 .69 .3 5658115642 0.79 0.9 2165465455 Attic Zone 2 Roof pitch is >= 2 :12 Clay roof tiles No .9 .6 .3 513465489 0.79 0.9 Attic Zone 3 Roof pitch is >= 2 :12 Clay roof tiles No .9 .6 .3 656654654 0.79 0.9 Attic Zone 4 Roof pitch is >= 2 :12 Clay roof tiles No .9 .6 .3 125654546 0.79 0.9 Attic Zone 5 Roof pitch is >= 2 :12 Clay roof tiles No .9 .6 .3 12565465 0.79 0.9 Attic Zone 6 Roof pitch is >= 2 :12 Clay roof tiles No .9 .6 .33 3214646 0.79 0.9 3651564 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 4 of 5) Registration Number: 422-P010021377A-000-001-E04060A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 I. Roofing Products (Cool Roof) - Additional Requirements 01 Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements 02 Liquid field applied coatings must comply with installation criteria from section 110.8(i)4 03 Mass roof 25 lb/ft2 or greater: Mass roofs are not required to have a cool roof even if the climate zone specifies minimum performance requirements The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 5 of 5) Registration Number: 422-P010021377A-000-001-E04060A-0000 Registration Date/Time: 2023-04-24   13:59:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:57 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-E21021A-0000 Registration Date/Time: 2023-04-24   13:20:11 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:11 CERTIFICATE OF INSTALLATION CF2R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Air Barrier Materials 01 A continuous sealed exterior air barrier is required in all thermal envelope assemblies to limit air movement between unconditioned/ outside spaces and conditioned/ inside spaces, and must comply using one of the following methods: 1.Using individual materials that have an air permeance not exceeding 0.004 cfm/ft2 under a pressure differential of 0.3 in. w.g. (1.57 pcf) (0.02 L/s.m2 at 75 pa) when tested in accordance with ASTM E2178; or 2.Using assemblies of materials and components that have an average air leakage not to exceed 0.04 cfm/ft2 under a pressure differential of 0.3 in. w.g. (1.57 pcf) (0.2 L/s.m2 at 75 pa) when tested in accordance with ASTM E2357, ASTM E1677, ASTM E1680, or ASTM E283; or 3.Testing the complete building and demonstrating that the air leakage rate of the building envelope does not exceed 0.40 cfm/ft 2 under a pressure differential of 0.3 in. w.g. (1.57 pcf) (2.0 L/s.m2 at 75 pa) when tested in accordance with ASTM E779 or an equivalent approved method. 02 Method of Compliance Method 1 (Individual Materials) Note:      SPF insulation is an acceptable air barrier and sealant when installed to a minimum thickness of 2 inches for closed cell and 5.5 inches for open cell, except where not allowed by manufacturer (e.g. flues, vents, can lights, etc). The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. B. Raised Floor Adjacent to Unconditioned Space or Separate Dwelling Units 01 All gaps in the raised floor are sealed. 02 All chases sealed at floor level using a sealed hard cover. 03 All holes (e.g. for plumbing and electrical wires) that penetrate the floor or bottom plates of walls are sealed. 04 Subfloor sheathing is glued or sealed at all panel edges to create a continuous air tight subfloor air barrier. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. C. Walls Adjacent to Unconditioned Space 01 All penetrations through the exterior wall air barrier are sealed to provide an air-tight envelope to unconditioned spaces such as the outdoors, attic, garage and crawl space. 02 Exterior wall air barrier is sealed to the top plate and bottom plate in each stud bay. 03 All electrical boxes, including knockouts that penetrate the air barrier to unconditioned space are sealed. 04 All openings in top and bottom plate, including all interior and exterior walls, to unconditioned space are sealed; such as holes drilled for electrical and plumbing. 05 Exterior bottom plates (all stories) are sealed to the floor. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 2 of 5) Registration Number: 422-P010021377A-000-001-E21021A-0000 Registration Date/Time: 2023-04-24   13:20:11 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:11 C. Walls Adjacent to Unconditioned Space 06 All gaps around windows and doors are sealed. The sealant used follows manufacturer specifications. 07 Rim joist gaps and openings are fully sealed. 08 Fan exhaust duct outlet/ damper at the exterior wall are sealed. 09 Knee walls have solid and sealed blocking at the bottom, top, left and right sides to prevent air movement into insulation. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. D. Ceiling Air Barrier Adjacent to Unconditioned Space 01 There is a continuous air barrier at the ceiling level. All openings into walls, drops, chases or double walls are sealed. 02 All penetrations through the top plate of interior and exterior walls are sealed. 03 Fire sprinklers penetrating a ceiling air barrier shall be sealed to prevent air movement according to the manufacturer's instructions. 04 All fixtures cut into the ceiling air barrier (e.g. HVAC registers, electrical boxes, fire alarm boxes, exhaust fan housing, and recessed lighting fixtures) are sealed to the surrounding dry wall. If it is not possible to seal the fixture directly, a secondary air barrier shall be created around the fixture. 05 All installed recessed lighting fixtures that penetrate the ceiling to unconditioned space are rated to be Insulation Contact and Airtight (IC and AT) which allow direct contact with insulation. 06 All dropped ceiling areas are covered with hard covers that are sealed to the framing, or else the bottom and sides of dropped ceiling areas are all insulated and sealed as ceilings and walls as required on the Certificate of Compliance. 07 All vertical chases (e.g. HVAC ducts and plumbing) and soffits are sealed at the ceiling level. 08 Chimneys and flues require sheet metal flashing at the ceiling level. The flashing shall be sealed to the chimney/flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 09 Framing locations where air may move down into the walls from the attic (e.g. double walls, pocket doors, architectural bump-outs, etc) have a sealed hard cover to prevent air movement. 10 Attic access forms an airtight seal between the conditioned space and unconditioned space. Vertical attic access requires mechanical compression using screws or latches. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. E. Roof Air Barrier - Unvented Attics Adjacent to Unconditioned Space 01 There is a continuous air barrier at the roof deck and gable ends. 02 Chimneys and flues require sheet metal flashing at the roof deck. The flashing shall be sealed to the chimney/flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 03 All penetrations in the roof deck and gable ends for plumbing, electrical, etc. are sealed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 3 of 5) Registration Number: 422-P010021377A-000-001-E21021A-0000 Registration Date/Time: 2023-04-24   13:20:11 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:11 F. Conditioned Space Above Or Adjacent To Garage Air Barrier 01 All penetrations in the subfloor above the garage into conditioned space must follow the raised floor air barrier requirements above. 02 Infiltration between the space above the garage and subfloor is prevented by one of the following methods: •Seal all edges of garage ceiling (typically drywall) at the perimeter of the garage to create a continuous air tight surface between the garage and adjacent conditioned envelope. Seal all plumbing, electric and mechanical penetrations between the garage and the adjacent conditioned space. For an open-web truss, airtight blocking is added on four sides of the garage perimeter. Insulation can be placed on the garage ceiling. •Seal the band joist above the wall at the garage to conditioned space transition. Seal all subfloor seams and penetrations between the garage and adjacent conditioned space. Insulation must be placed in contact with the subfloor below the conditioned space. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Cantilevered Floor Air Barrier 01 Airtight blocking is installed between joists where the wall rim joist would have been located in the absence of a cantilever. 02 Exterior sheathing is installed to the bottom of the cantilever so that there is a continuous air and weather barrier for the cantilever. The cantilevered joist must be insulated to the same R value as would be required for the subfloor prior to closing. 03 Any gaps, cracks or penetrations in the air barrier of the cantilever are sealed. Recessed can lights in the cantilever are IC and AT and properly sealed to the sheathing. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. H. Walls For Attached Porch, Attic, Double Wall Air Barrier 01 An exterior wall air barrier is required at the intersection of the porch and exterior wall when there is conditioned space on the other side. The exterior wall includes an air barrier where the attic attaches to the conditioned space. 02 Truss framing blocking is used at the top and bottom of each wall/ roof section. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. I. Air Barriers in Multifamily Dwellings 01 Each dwelling unit must be sealed to stop air movement between dwelling units. Treat adjacent dwelling units as unconditioned space for air sealing. 02 All penetrations through the floor and ceiling of each dwelling unit are sealed including, electric and gas utilities, water pipes, drain pipes, fire protection service pipes, and communication wiring. 03 Elevator penthouse, mechanical penthouse, stairwell doors, roof access hatches, and plumbing stacks that separate conditioned and unconditioned space are all sealed. 04 Vertical chases for garbage chutes, elevator shafts, HVAC ducting and plumbing shall be treated as unconditioned space for sealing. 05 Common hallways shall be treated as unconditioned space for sealing. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 4 of 5) Registration Number: 422-P010021377A-000-001-E21021A-0000 Registration Date/Time: 2023-04-24   13:20:11 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:11 J. Special Requirements for SIPs 01 SIPs are considered an air barrier when properly sealed at top, bottom, sides and all penetrations. 02 Air barrier is continuous across all surfaces, including between SIPs and non-SIP sections. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. K. Special Requirements for ICF 01 ICF sections are considered an air barrier when properly sealed at top, bottom, sides and all penetrations. 02 Air barrier is continuous across all surfaces, including between ICF and non-ICF sections. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 5 of 5) Registration Number: 422-P010021377A-000-001-E21021A-0000 Registration Date/Time: 2023-04-24   13:20:11 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:11 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-E22020A-0000 Registration Date/Time: 2023-04-24   13:20:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:06 CERTIFICATE OF INSTALLATION CF2R-ENV-22-H QII - Insulation Installation (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Insulation Materials Installed 01 Roof Deck Insulation Material Installed n/a 02 Ceiling Insulation Material Installed n/a 03 Exterior Wall Insulation Material Installed Batt and Blanket 04 Raised Floor Insulation Material Installed n/a 05 Slab Edge Insulation Material Installed n/a B. All Surfaces 01 Air barrier installation and preparation for insulation was done and verified prior to insulation being installed. 02 All surfaces between conditioned and unconditioned space are sealed and insulated to meet or exceed the levels specified on the Certificate of Compliance 03 All structural framing areas shall be insulated in a manner that resists thermal bridging through the assembly separating conditioned from unconditioned space. Structural bracing, tie-downs, and framing of steel, or specialized framing used to meet structural requirements of the CBC are allowed and must be insulated. These areas shall be called out on the building plans with diagrams and/ or specified design drawings indicating the R-value of insulation and fastening method to be used. 04 All insulation was installed according to the manufacturer's installation instructions. 05 Labels or specification/ data sheets for each insulation material shall be provided to the HERS rater. Loose-fill material includes insulation material bag labels or coverage charts. 06 Loose-fill insulation - the installed depth and density of insulation is verified in at least 6 random locations to ensure that the minimum thickness and installed density meet R-value specified on the Certificate of Compliance, and are consistent with the manufacturer's coverage chart. 07 If kraft paper faced insulation is used, paper is installed on the conditioned (warm in winter) side of surface. Paper must be in contact with air barrier to within 2" framing (stud, joists, etc.). The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. C. Raised Floor Adjacent to Unconditioned Space 01 Insulation is in full contact with the subfloor. 02 Insulation hangers are spaced at 18 inches or less. Insulation hangers do not compress insulation. 03 Netting, or mesh, can be used if the cavity under the floor is filled and in contact with the subfloor. 04 When daylight basements are adjacent to crawlspaces, if the basement is conditioned the walls adjacent to the crawlspace are insulated to the R-value listed on the Certificate of Compliance. This includes framed stem walls, and vertical concrete retaining walls. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-22-H QII - Insulation Installation (Page 2 of 5) Registration Number: 422-P010021377A-000-001-E22020A-0000 Registration Date/Time: 2023-04-24   13:20:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:06 C. Raised Floor Adjacent to Unconditioned Space 05 If access to the crawlspace is from the conditioned area the raised floor includes an airtight insulated access hatch. Where possible locate crawl space access on the exterior. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. D. Walls Adjacent to Unconditioned Space 01 Insulation quality was verified prior to the installation of the interior air barrier (typically gypsum board). 02 Loose-fill and batt insulation is in contact with all six sides of wall cavities (top, bottom, back, left, right, front [to be installed later]) with no gaps, voids or compression. Special Situation: Where framing depth is greater than required insulation thickness (e.g., double walls or framed bump-outs) a secondary air barrier shall be installed and in contact with the insulation, so that the insulation fills the cavity formed by the additional air barrier. 03 Insulation fits snuggly around obstructions (e.g., electrical boxes, plumbing and wiring) with no gaps, voids or compression. 04 Structural metal tie-downs and shear panels are insulated between exterior air barrier and metal. 05 Hard to access wall stud cavities, such as corner channels or wall intersections, are insulated to the proper R-value prior to the installation of exterior sheathing or exterior stucco lathe. 06 Insulation and interior air barrier are installed behind tub, shower, fireplace enclosures and stairwells to the R-value listed on the Certificate of Compliance when located against exterior walls. 07 All single-member window and door headers shall be insulated to a minimum of R-3 for a 2x4 framing, or equivalent width, and a minimum of R-5 for all other assemblies. No header insulation is required for single-member headers that are the same width as the wall, provided that the entire wall has at least R-2 insulation. 08 After insulation is installed: All insulated walls have interior and exterior air barriers, including kneewalls and walls of skylight wells. Exception: Rim joists. Interior air barrier (typically gypsum board) is sealed to top plate. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. E. Ceiling Adjacent to Unconditioned Space 01 Insulation extends to the outside surface of the exterior wall. 02 Insulation is in direct contact with the ceiling air barrier so there are no gaps, voids or compression. 03 Chimneys and flues (except zero clearance) have a sheet metal collar at the ceiling level to prevent contact with the insulation. The collar is at least as tall as the depth of the insulation. There is a minimum 1" clearance between the collar and the chimney/flue for double wall vent, and 6" for single wall vent, unless manufacturer's instructions require otherwise. The collar is sealed to the ceiling with high temperature sealant to prevent air leakage. The insulation is in contact with the sheet metal collar. 04 Recessed can lights penetrating the ceiling air barrier are covered with insulation to the depth needed to meet the ceiling R-value specified on the Certificate of Compliance. 05 External surfaces of steel studs, steel-framed kneewalls, skylight shafts, and gable ends are covered with insulation. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-22-H QII - Insulation Installation (Page 3 of 5) Registration Number: 422-P010021377A-000-001-E22020A-0000 Registration Date/Time: 2023-04-24   13:20:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:06 F. Ceiling Insulation in Vented Attics 01 Required eave ventilation shall not be obstructed. The net-free ventilation area of the eave vent is maintained. 02 Eave vent baffles and dams are installed to prevent air movement under or into the ceiling insulation. 03 Attic access is insulated to the same R-value required by the Certificate of Compliance for ceiling insulation and the insulation is permanently attached using adhesive or mechanical fasteners. 04 Attic access must have a dam around the access to at least the same depth as the insulation. 05 Attic rulers specified to the installed loose-fill material (brand and type) are installed and evenly distributed throughout the attic to verify depth (one ruler for every 250 ft2). The rulers are clearly readable and scaled to read inches of insulation and the R-value installed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Insulation in unvented Attics 01 The roof sheathing is the air barrier and is sealed to prevent air movement to the outside. 02 Insulation is in full contact with the air barrier (roof sheathing). 03 If insulated using air permeable insulation, gable end walls are sealed and insulated the same as exterior walls, including interior air barrier. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. H. Insulation in Vented Attics (High Performance Vented Attics) 01 Insulation is in full contact with roof sheathing and firmly supported to prevent sagging. 02 Batt insulation between roof trusses is acceptable with minimal gaps and voids caused by roof truss members. 03 Insulation is not required on gable end walls. 04 Required roof deck insulation over any conditioned space, or HVAC ducts, is installed on the entire attic roof deck; even over unconditioned spaces (e.g., garage, covered porch). Roof deck of attic over unconditioned space without HVAC ducts and separated from other attics by a sealed air barrier do not need to be insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. I. Special Requirements for Skylight Shafts and Attic Knee Walls 01 Insulation must meet all the requirements for walls and insulation is in contact with the air barrier on all six sides unless SPF is used. 02 Insulation shall be in full contact with the interior wall finish. Batt insulation must be cut to fit around 2x4's that are laid flat. 03 Skylight shafts and attic knee walls shall be completely enclosed by vertical and horizontal framing, including horizontal plates at the top and bottom of the insulation. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-22-H QII - Insulation Installation (Page 4 of 5) Registration Number: 422-P010021377A-000-001-E22020A-0000 Registration Date/Time: 2023-04-24   13:20:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:06 J. Special Requirements for Floors Above Garages 01 If the air barrier is at the perimeter of the garage below the conditioned subfloor, then the insulation may be placed on the garage ceiling. The perimeter of the subfloor must also be insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. K. Special Requirements for Cantilevered Floors 01 Sealed blocking shall be installed between joists where the wall rim joist would have been located in the absence of a cantilever. Insulation shall be placed on both sides of the block. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. L. Special Requirements for Attached Porches 01 Exterior wall at the intersection of the porch roof is fully insulated above, below and behind the roof line. 02 Where truss framing is used, airtight blocking is used at the top and bottom of each wall/ roof section and is insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. M. Special Requirements for SPF Insulation 01 Installed product meets the claimed R-value per inch. Non-standard values are supported by an ICC Evaluation Service Report (ESR) number (e.g., ESR-xxxx) and documented on the CF2R-ENV-03. Non-standard values are anything greater than R-5.8/inch for closed cell and R-3.6/inch for open cell. 02 Installed thickness meets the required R-value from the Certificate of Compliance. Verified in at least 6 random places for each surface type: floors, walls and ceilings. 03 Insulation is spray applied to fully adhere to structural assembly framing, floor and ceiling joists, and other framing surfaces within the construction cavity. 04 If multiple layers are applied, each foam lift (e.g., spray application) adheres to the substrate and foam interfaces. 05 Closed cell SPF: In area where an air barrier is required the foam is at least 2" thick. 06 Open cell SPF: In area where an air barrier is required the foam is at least 5.5" thick. 07 Open cell SPF: Depressions in the foam insulation are not greater than 1/2" of the required thickness provided these depressions do not exceed 10% of the surface area being insulated. 08 Open cell SPF: Insulation completely fills cavities of 2x4 framing. 09 SPF insulation is not applied directly to recessed lighting fixtures unless specifically allowed by manufacturer's instructions. when not allowed, can lights are: A.Covered with a minimum of 1.5" of mineral fiber insulation or B.Enclosed in a manufacturer's approved box fabricated from an approved material, such as 18 gauge sheet metal or 1/2" gypsum board. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-22-H QII - Insulation Installation (Page 5 of 5) Registration Number: 422-P010021377A-000-001-E22020A-0000 Registration Date/Time: 2023-04-24   13:20:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:20:06 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-L01025A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:25:55 CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Installed Lighting and Controls Select Yes or No according to whether your work on the project includes each of the following types of lighting and controls. See sections B through H for applicable requirements. 01 High Efficacy luminaires installed in any interior rooms. (See Section B.) No 02 JA8 compliant luminaires and controls installed in any interior rooms. (See Section B.) No 03 Recessed downlight luminaires in ceilings in any interior room (See Section C). No 04 Screw-based luminaires installed in any interior rooms (See Section D.) No 05 Enclosed or recessed luminaires installed in any interior room (See Section D). No 06 Lighting and controls in bathrooms (See Section E.)No 07 Lighting and controls in laundry rooms (See Section E.)No 08 Lighting and controls in utility rooms (See Section E.)No 09 Lighting and controls in garage (See Section E.)No 10 Outdoor lighting and controls (See Section H.)No 11 Blank electrical boxes installed more than 5 feet from finished floor. (See Section F.) No 12 Internally illuminated address signs. (See Section G.)No B. High Efficacy Luminaires and Controls This section does not apply to this project. C. Recessed Downlight LuminaIres in Ceilings This section does not apply to this project. D. Additional Luminaire Requirements This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 2 of 3) Registration Number: 422-P010021377A-000-001-L01025A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:25:55 E. Additional Lighting Controls This section does not apply to this project. F. Blank Electrical Boxes This section does not apply to this project. G. Address Signs This section does not apply to this project. H. Single Family Outdoor Lighting This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 3 of 3) Registration Number: 422-P010021377A-000-001-L01025A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:25:55 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 14) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. General Information 01 Dwelling Unit Name Single Family Dwelling 02 Climate Zone 15 03 Dwelling Unit Total Conditioned Floor Area (ft2)9391 04 Number of Space Conditioning Systems in this dwelling unit.6 05 Certificate of Compliance Type Performance (CF1R-PRF)06 Method Used to Calculate HVAC Loads ACCA Manual J 07 Calculated Dwelling Unit Sensible Cooling Load (Btu/h)156000 08 Calculated Dwelling Unit Heating Load (Btu/h)186000 09 Dwelling Unit Number of Bedrooms 6 MCH-01a - Space Conditioning Systems Ducts and Fans - For use with Performance Certificate of Compliance NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 2 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 B. Design Space Conditioning (SC) System Component Specifications from CF1R This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project. 01 02 03 04 05 06 07 08 09 10 11 SC System ID/Name from CF1R SC System Type Heating System Type Cooling System Type Central Fan Ventilation Cooling System Type Distribution System Type Required Thermostat Type Low Leakage Air-Handling Unit (LLAHU) Status Bypass Duct Status Cooling Zoning Type Cooling System Compressor Speed HVAC System 11 Heat pump heating cooling Central split HP Central split HP Not a CFVCS Outdoor locations Setback Yes credit is taken No Bypass Duct Not Zonal Multi-speed HVAC System 22 Heat pump heating cooling Central split HP Central split HP Not a CFVCS Outdoor locations Setback Yes credit is taken No Bypass Duct Not Zonal Multi-speed HVAC System 33 Heat pump heating cooling Central split HP Central split HP Not a CFVCS Outdoor locations Setback Yes credit is taken No Bypass Duct Not Zonal Multi-speed HVAC System 44 Heat pump heating cooling Central split HP Central split HP Not a CFVCS Unconditioned attic Setback No, credit is not taken No Bypass Duct Not Zonal Multi-speed HVAC System 55 Heat pump heating cooling Central split HP Central split HP Not a CFVCS Unconditioned attic Setback Yes credit is taken No Bypass Duct Not Zonal Multi-speed HVAC System 66 Heat pump heating cooling Central split HP Central split HP Not a CFVCS Unconditioned attic Setback Yes credit is taken No Bypass Duct Not Zonal Multi-speed Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 3 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 C. Design Space Conditioning (SC) System Compliance Requirements from CF1R This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project. 01 02 03 04 05 06 07 08 09 10 11 12 SC System ID/ Name from CF1R Heating Efficiency Type Minimum Heating Efficiency Value (%) Heat Pump Heating Capacity at 47 °F Heat Pump Heating Capacity at 17 °F Minimum Cooling Efficiency SEER Minimum Cooling Efficiency EER/CEER Minimum Cooling System Airflow Rate (CFM/ton) Maximum Fan Efficacy (W/CFM) Modeled Duct R-Value Central Fan Ventilation Cooling Airflow Central Fan Ventilation Cooling Fan Efficacy HVAC System 11 HSPF 11 59000 49500 21 13 350 0.31 R-8 n/a n/a HVAC System 22 HSPF 11 59000 49500 21 13 350 0.31 R-8 n/a n/a HVAC System 33 HSPF 10.5 34600 32600 21 13 350 0.22 R-8 n/a n/a HVAC System 44 HSPF 10 27600 26200 18.6 12.5 350 0.18 R-8 n/a n/a HVAC System 55 HSPF 10.5 34600 32600 21 13 350 0.24 R-8 n/a n/a HVAC System 66 HSPF 10.5 34600 32600 21 13 350 0.28 R-8 n/a n/a Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 4 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 D. Installed Space Conditioning (SC) System Component Information 01 02 03 04 05 06 07 08 09 10 SC System ID/ Name from CF1R SC System Description of Area Served Conditioned Floor Area Served by the System (ft2) Heating System Type Cooling System Type Number of Indoor Units for this System Distribution System Type SC System Thermostat Type Cooling Zoning Type Cooling System Compressor Speed Type HVAC System 11 Master 1391 Central split HP Central split HP 1 Outdoor locations Setback Not Zonal Multi-speed HVAC System 22 Bedrooms 1000 Central split HP Central split HP 1 Outdoor locations Setback Not Zonal Multi-speed HVAC System 33 Kids room 1750 Central split HP Central split HP 1 Outdoor locations Setback Not Zonal Multi-speed HVAC System 44 Kitchen 1750 Central split HP Central split HP 1 Unconditioned attic Setback Not Zonal Multi-speed HVAC System 55 Living Room 1750 Central split HP Central split HP 1 Unconditioned attic Setback Not Zonal Multi-speed HVAC System 66 Great Room 1750 Central split HP Central split HP 1 Unconditioned attic Setback Not Zonal Multi-speed Notes: E. Installed Heating System Equipment Information (not heat pumps) This section does not apply to this project. F. Installed Cooling System Outdoor Condensing Unit or Package Unit Equipment Information (not heat pumps) This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 G. Installed Split System Indoor Unit ( Coil or Fan Coil) Equipment Information - applicable to DX or hydronic heating or cooling, coils and fan coil units. Systems with more than one indoor unit coil or fan coil unit (e.g. multi-split systems) shall provide information for each of the system indoor coils or fan coil units. 01 02 03 04 05 06 07 08 09 10 SC System ID/ Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Indoor Unit Type Indoor Unit Duct Status Does Indoor Unit Provide CFI IAQ Ventilation? Indoor Unit Manufacturer Indoor Unit Model Number Indoor Unit Serial Number Indoor Unit Nominal Cooling Capacity (ton) HVAC System 11 Master Master HP Coil Ducted > 10ft length No Carrier FN1AAF01500 13456 Value not required HVAC System 22 Bedrooms Bedrooms HP Coil Ducted > 10ft length No Carrier FN1AAF01500 13456 Value not required HVAC System 33 Kids room Kids room HP Coil Ducted > 10ft length No Carrier FN1AAF01500 13456 Value not required HVAC System 44 Kitchen Kitchen HP Coil Ducted > 10ft length No Carrier FN1AAF01500 13456 Value not required HVAC System 55 Living Room Living Room HP Coil Ducted > 10ft length No Carrier FN1AAF01500 13456 Value not required HVAC System 66 Great Room Great Room HP Coil Ducted > 10ft length No Carrier FN1AAF01500 13456 Value not required Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 H. Installed Heat Pump System - Split System Condensing Unit or Package Unit Equipment Information 01 02 03 04 05 SC System ID/ Name from CF1R SC System Description of Area Served Condenser or Package Unit Manufacturer Condenser or Package Unit Model Number Condenser or Package Unit Serial Number HVAC System 11 Master HVAC System 22 Bedrooms HVAC System 33 Kids room HVAC System 44 Kitchen HVAC System 55 Living Room HVAC System 66 Great Room Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 I. Installed Heat Pump System -Efficiency and Performance Compliance Information 01 02 03 04 05 06 07 08 09 10 SC System ID/ Name from CF1R SC System Description of Area Served Heating Efficiency Type Heating Efficiency Value System Rated Heating Capacity at 47 °F System Rated Heating Capacity at 17 °F System Rated Cooling Efficiency SEER System Rated Cooling Efficiency EER/CEER System Cooling Capacity at Design Conditions (Btu/h) Condenser Nominal Capacity (ton) HVAC System 11 Master HSPF 96 59000 49500 21 13 36000 3 HVAC System 22 Bedrooms HSPF 96 59000 49500 21 13 36000 3 HVAC System 33 Kids room HSPF 96 34600 32600 21 13 36000 3 HVAC System 44 Kitchen HSPF 95.99 27600 26200 18.6 12.5 36000 3 HVAC System 55 Living Room HSPF 95.99 34600 32600 21 13 60000 4.99 HVAC System 66 Great Room HSPF 96 34600 32600 21 13 60000 5 Notes: J. Installed Duct System Information 01 02 03 04 05 06 07 08 09 10 11 12 13 14 SC System ID/ Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Supply Duct Location Supply Duct R-Value Return Duct Location Return Duct R-Value Exception from Min R-Value Method of compliance with Airflow and Fan Efficacy Req's in 150.0(m)13 Bypass Duct Status Number of Air Filter Devices on Indoor Unit Can Approved Airflow Protocols be used to test this System? Can Approved Fan Efficacy Protocol be used to test this System? Total Duct Length HVAC System 11 Master Master Uncondition edAttic R8 Uncondition edAttic R8 NoException HERS_FanEff icacyAirflow Rate false 1 Yes Yes DuctsGT10F t HVAC System 22 Bedrooms Bedrooms Uncondition edAttic R8 Uncondition edAttic R8 NoException HERS_FanEff icacyAirflow Rate false 1 Yes Yes DuctsGT10F t NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 8 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 J. Installed Duct System Information 01 02 03 04 05 06 07 08 09 10 11 12 13 14 SC System ID/ Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Supply Duct Location Supply Duct R-Value Return Duct Location Return Duct R-Value Exception from Min R-Value Method of compliance with Airflow and Fan Efficacy Req's in 150.0(m)13 Bypass Duct Status Number of Air Filter Devices on Indoor Unit Can Approved Airflow Protocols be used to test this System? Can Approved Fan Efficacy Protocol be used to test this System? Total Duct Length HVAC System 33 Kids room Kids room Uncondition edAttic R8 Uncondition edAttic R8 NoException HERS_FanEff icacyAirflow Rate false 0 Yes Yes DuctsGT10F t HVAC System 44 Kitchen Kitchen Uncondition edAttic R8 Uncondition edAttic R8 NoException HERS_FanEff icacyAirflow Rate false 0 Yes Yes DuctsGT10F t HVAC System 55 Living Room Living Room Uncondition edAttic R8 Uncondition edAttic R8 NoException HERS_FanEff icacyAirflow Rate false 1 Yes Yes DuctsGT10F t HVAC System 66 Great Room Great Room Uncondition edAttic R8 Uncondition edAttic R8 NoException HERS_FanEff icacyAirflow Rate false 1 Yes Yes DuctsGT10F t NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 9 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 K. Installed Air Filter Device Information Mandatory requirements for air filter devices are specified in Section 150.0(m)12. The installer shall place a sticker in or near the filter grille displaying the filter grille/rack design airflow rate and the maximum allowed clean filter pressure drop at the design airflow rate. This will inform the occupant of the airflow vs pressure drop performance required for replacement air filters. 01 02 03 04 05 06 07 08 09 10 11 12 13 SC System ID/ Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Air Filter Device Name or Description of Area Served Air Filter Device Type Design Airflow Rate for Air Filter Device (cfm) Air Filter Nominal Depth (inch) Air Filter Nominal Length (inch) Air Filter Nominal Width (inch) Air Filter Calculated Nominal Face Area (inch2) Air Filter Required Minimum Face Area (inch2) Face Area Compliance Design Allowable Pressure Drop for Air Filter Device (inch W.C.) HVAC System 11 Master Master Filter 1 Filter Grille 1200 3 36 36 1296 Specified by System Designer Specified by System Designer .25 HVAC System 22 Bedrooms Bedrooms Filter 2 Filter Grille 1200 3 36 36 1296 Specified by System Designer Specified by System Designer .25 HVAC System 33 Kids room Living Room Filter 3 Filter Grille 12000 4 36 36 1296 Specified by System Designer Specified by System Designer .25 HVAC System 44 Kitchen Great Room Filter 4 Filter Grille 1 4 36 36 1296 Specified by System Designer Specified by System Designer .25 Notes: L. Air Filter Device Requirements 01 The system shall be designed to ensure that all recirculated air and all outdoor air supplied to the occupiable space is filtered before passing through the system's thermal conditioning components. 02 The system shall be designed to accommodate the clean-filter pressure drop imposed by the system air filter device(s). The design airflow rate and maximum allowable clean-filter pressure drop at the design airflow rate applicable to each air filter shall be determined by the system designer. The system installer shall affix a sticker/label to each system air filter grille/rack location that discloses the filter's design airflow rate and the filter's maximum allowable clean-filter pressure drop at the design airflow rate. The sticker/labels shall be permanently affixed to the air filter grille/rack, readily legible, and visible to a person replacing the air filter. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 10 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 L. Air Filter Device Requirements 03 All system air filter devices shall be located and installed in such a manner as to allow access and regular service by the system owner. 04 The system shall be provided with air filter media having a designated efficiency equal to or greater than MERV 13 when tested in accordance with ASHRAE Standard 52.2, or a particle size efficiency rating equal to or greater than 50% in the 0.30 to 1.0 µm range and equal to or greater than 85 percent in the 1.0 - 3.0 µm range when tested in accordance with AHRI Standard 680. 05 The system shall be provided with air filters that have been labeled by the manufacturer to disclose efficiency and pressure drop ratings that conform to the efficiency and pressure drop requirements for the air filter grilles/racks.. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met M. HERS Verification Requirements For Duct Systems 01 02 03 04 05 06 07 08 09 10 SC System ID/ Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served MCH-20 Duct Leakage Test MCH-21 Duct Location Verification MCH-22 AHU Fan Efficacy (W/cfm) MCH-23 AHU Airflow Rate (cfm/ton) MCH-28 Return Duct Design Table 150.0-B or C MCH-29 Supply Duct Surface Area R-Value Buried Ducts MCH30 Central Fan Ventilation Cooling Credit HVAC System 11 Master Master Yes No Yes Yes No No No HVAC System 22 Bedrooms Bedrooms Yes No Yes Yes No No No HVAC System 33 Kids room Kids room Yes No Yes Yes No No No HVAC System 44 Kitchen Kitchen Yes No Yes Yes No No No HVAC System 55 Living Room Living Room Yes No Yes Yes No No No HVAC System 66 Great Room Great Room Yes No Yes Yes No No No Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 11 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 N. HERS Verification Requirements For Space Conditioning Equipment 01 02 03 04 05 SC System ID/ Name from CF1R SC System Description of Area Served MCH-25 Refrigerant Charge MCH-26 Rated SC System Equipment Verification MCH-33 VCHP Compliance Credit HVAC System 11 Master Yes Yes No HVAC System 22 Bedrooms Yes Yes No HVAC System 33 Kids room Yes Yes No HVAC System 44 Kitchen No Yes No HVAC System 55 Living Room Yes Yes No HVAC System 66 Great Room Yes Yes No Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 12 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 O. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 150.0(h)1 and 2). 04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature rise specification. See Section 150.0(h)4. 05 Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment 06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. 09 Liquid Line Filter Drier: A liquid line filter drier shall be installed according to the manufacturer's specifications 150.0(h)3B 10 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)1 and 2. Air Distribution System Ducts, Plenums and Fans 11 Insulation: The minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)1. 12 Connections and Closures: All installed air-distribution system ducts and plenums must meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0, otherwise a minimum of R-4.2 is allowed if the system is enclosed entirely in conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Exceptions for ducts in interior wall cavities or exposed ducts entirely in conditioned space are specified in Section 150.0(m)1B. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 13 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 O. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heat Pump Thermostat 13 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 14 The thermostat shall be installed in accordance with the manufacturers published installation specifications 15 First stage of heating shall be assigned to heat pump heating. 16 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 14 of 14) Registration Number: 422-P010021377A-000-001-M01001A-0000 Registration Date/Time: 2023-04-24   13:14:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:19 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M27005A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:14:32 CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2.-2016 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings subject to amendments specified by Title 24, Part 6 Section 150.0(o)1. A. Dwelling Mechanical Ventilation - General Information 01 Dwelling unit name Single Family Dwelling 02 Building Type Single family detached 03 Project scope Newly Constructed 04 Total Conditioned Floor Area of Dwelling Unit (For addition projects the conditioned floor area equals existing area plus addition area. ) 9391 05 Number of Bedrooms in Dwelling Unit (For addition projects the number of bedrooms equals the existing bedrooms plus addition bedrooms) 6 06 Ventilation System Type Exhaust 07 Ventilation Operation Schedule Continuous Note: Non-dwelling units do not meet the definition for a dwelling unit as defined in Section 100.1(b). Non-dwelling units are not designed to provide independent living facilities and do not provide permanent provisions for living, sleeping, eating, cooking and sanitation. B. Single Family Attached/Detached General Information 01 Average Ceiling Height 8 02 Total Conditioned Volume 75128 03 Vertical distance between the lowest and highest above grade points within the pressure boundary in feet 22 04 Air Changes Per Hour at 50 Pa Default 05 Name of ANSI/ASHRAE Standard 62.2-2016 weather station for climate zone Palm Springs Intl 06 Weather and shielding factor (wsf) (Based on city identified above)0.45 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 2 of 5) Registration Number: 422-P010021377A-000-001-M27005A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:14:32 C. Ventilation - Total Ventilation Rate A mechanical supply system, exhaust system or combination thereof shall provide whole-building ventilation with outdoor air each hour at no less than the rate in 150.0(o)1Ci 01 Total Required Ventilation Rate (Qtot)334.23 02 Enclosure Leakage Rate (Q50)2504.27 03 Effective Annual Average Infiltration Rate (Qinf 86.96 04 Total Exterior Envelope Surface Area n/a 05 Unshared Exterior Envelope Surface Area (exclude surface areas attached to garages or other dwelling units) n/a 06 Required Mechanical Ventilation Rate (Qfan)311.6 D. Installed Ventilation - Total Ventilation Rate A mechanical supply system, exhaust system, or combination thereof shall provide whole-building ventilation with outdoor air each hour at no less than the rate in 150.0(o)1Ci 01 02 03 04 05 Fan Name Fan Location Runtime (min/hr)Installed Mechanical Ventilation Rate (CFM) Equivalent Continuous Ventilation (CFM) 60 400 400 06 Total Installed Continuous Ventilation (CFM)400 E. Compliance Statement 01 Building Passes Mechanical Ventilation RateTest F. Other Requirements The items listed below (6.1 through 6,6 abd 6.8 through 6.9) correspond to the information given in ASHRAE 62.2 Section 6 "Other Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.8) for information describing these "Other Requirements". The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable. 01 6.1 Adjacent Spaces and Transfer Air.Measures shall be taken to minimize air movement across envelope components to dwelling units from adjacent spaces such as garages, unconditioned crawl spaces, unconditioned attics and other dwelling. Supply and balanced ventilation systems shall be designed and constructed to provide ventilation air directly from the outdoors.      6.1.1 Compliance for Attached Dwelling Units . One method of demonstrating compliance with Section 6.1 shall be to verify a leakage rate below a maximum of 0.3 cfm per ft2 (150 L/s per 100 m2) of the dwelling unit envelope per area (i.e. the sum of the area of walls between dwelling units, exterior walls, ceiling and floor) at a test pressure of 50 Pa by a blower door test conducted in accordance with either ANSI/ASTME779 or ANSI/ASTM-E1827. The test shall be conducted with the dwelling unit as if it were exposed to outdoor air on all sides, top and bottom by opening doors and windows of adjacent dwelling units. 02 6.2 Instructions and Labeling.Information on the ventilation design and/or ventilation systems installed, instructions on their proper operation to meet the requirements of this standard, and instructions detailing any required maintenance (similar to that provided for HVAC systems) shall be provided to the owner and the occupant of the dwelling unit. Controls shall be labeled as to their function (unless that function is obvious, such as toilet exhaust fan switches). See Chapter 13 of Guideline 245 for information on instructions and labeling. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 3 of 5) Registration Number: 422-P010021377A-000-001-M27005A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:14:32 F. Other Requirements The items listed below (6.1 through 6,6 abd 6.8 through 6.9) correspond to the information given in ASHRAE 62.2 Section 6 "Other Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.8) for information describing these "Other Requirements". The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable. 03 6.3 Clothes Dryers.Clothes dryers shall be exhausted directly to the outdoors. Exception: Condensing dryers plumbed to a drain. 04 6.4 Combustion and Solid-Fuel Burning Appliances.      6.4.1 Combustion and solid-fuel burning appliances must be provided with adequate combustion and ventilation air and vented in accordance with manufacturer installation instructions, NFPA 54 ANSI Z223.1,National Fuel Gas Code , NFPA 31,Standard for the Installation of Oil-Burning Equipment , or NFPA 211,Standard for Chimneys, Fireplaces, Vents, and Solid-Fuel Burning Appliances , or other equivalent code acceptable to the building official.      6.4.2 Where atmospherically vented combustion appliances or solid-fuel burning appliances are located inside the pressure boundary, the total net exhaust flow of the two largest exhaust fans (not including a summer cooling fan intended to be operated only when windows or other air inlets are open) shall not exceed 15 cfm/100 ft2 (75 L/s per 100 m2) of occupiable space when in operation at full capacity. If the designed total net flow exceeds this limit, the net exhaust flow must be reduced by reducing the exhaust flow or providing compensating outdoor airflow. Atmospherically vented combustion appliances do not include direct-vent appliances. Combustion appliances that pass safety testing performed according to ANSI/BPI-1200, Standard Practice for Basic Analysis of Buildings, 21 shall be deemed as complying with Section 6.4.2 05 6.5 Air Tightness Requirements      6.5.1 Garages.When an occupiable space adjoins a garage, the design must prevent migration of contaminants to the adjoining occupiable space. Air seal the walls, ceilings, and floors that separate garages from occupiable space. To be considered air sealed, all joints, seams, penetrations, openings between door assemblies and their respective jambs and framing, and other sources of air leakage through wall and ceiling assemblies separating the garage from the residence and its attic area shall be caulked, gasketed, weather stripped, wrapped, or otherwise sealed to limit air movement. Doors between garages and occupiable spaces shall be gasketed or made substantially airtight with weather stripping. 06 6.6 Ventilation Opening Area.Spaces shall have ventilation openings as listed below. Such openings shall meet the requirements of Section 6.8. Exception: Attached dwelling units and spaces that meet the local ventilation requirements set for bathrooms in Section 5 [of ASHRAE 62.2].      6.6.1 Habitable Spaces.Each habitable space shall be provided with ventilation openings with an openable area not less than 4% of the floor area or less than 5 ft2 (0.5 m2).      6.6.1 Toilets and Utility Rooms Toilets and utility rooms shall be provided with ventilation openings with an openable area not less than 4% of the floor area or less than 1.5 ft2 (0.5 m2). Exceptions: 1.Utility rooms with a dryer exhaust duct. 2.Toilet compartments in bathrooms. 07 6.8 Air Inlets.Air inlets that are part of the ventilation design shall be located a minimum of 10 ft (3 m) from known sources of contamination such as a stack, vent, exhaust hood, or vehicle exhaust. The intake shall be placed so that entering air is not obstructed by snow, plantings, or other material. Forced air inlets shall be provided with rodent/insect screens (mesh not larger than 1/2 inch [13 mm]). 1.Ventilation openings in the wall may be as close as a stretched-string distance of 3 ft (1 m) from sources of contamination exiting through the roof or dryer exhausts. 2.No minimum separation distance shall be required between windows and local exhaust outlets in kitchens and bathrooms. 3.Vent terminations covered by and meeting the requirements of the National Fuel Gas Code NFPA 54/ ANSI Z223.1)7 or equivalent. 4.Where a combined exhaust/intake termination is used to separate intake air from exhaust air originating in a living space other than kitchens, no minimum separation distance between these two openings is required. For these combined terminations, the exhaust air concentration within the intake air shall not exceed 10%, as established by the manufacturer. 08 6.9 Carbon Monoxide Alarms.A carbon monoxide alarm shall be installed in each dwelling unit in accordance with NFPA 720,Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment 14, and shall be consistent with requirements of applicable laws, codes, and standards. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 4 of 5) Registration Number: 422-P010021377A-000-001-M27005A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:14:32 G. Air Moving Equipment The items listed below (7.1 through 7.4) correspond to the information given in ASHRAE 62.2 Section 7 "Air-Moving Equipment". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.9) for information describing these requirements in more detail. The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 7.1 through 7.4 if applicable. 01 7.1 Selection and Installation.Ventilation devices and equipment shall be tested and listed in accordance with ANSI/ASHRAE Standard 51/ AMCA 210,Laboratory Methods of Testing Fans for Aerodynamic Performance Rating, and ANSI/AMCA Standard 300,Reverberant Room Method for Sound Testing of Fans, and rated in accordance with the airflow and sound rating procedures of the Home Ventilating Institute (HVI) (HVI 915,Loudness Testing and Rating Procedure; HVI 916 Airflow Test Procedure; and HVI 920,Product Performance Certification Procedure Including Verification and Challenge). Installations of systems or equipment shall be carried out in accordance with manufacturers' design requirements and installation instructions. 02 7.2 Sound Ratings for Fans.Ventilation fans shall be rated for sound at no less than the minimum airflow rate required by this standard, as noted below. These sound ratings shall be at a minimum of 0.1 in. w.c. (25 Pa) static pressure in accordance with the HVI procedure referenced in 7.1. Exception: HVAC air handlers and remote mounted fans need not meet sound requirements. To be considered for this exception, a remote mounted fan must be mounted outside the habitable spaces, bathrooms, toilets, and hallways, and there must be at least 4 ft (1 m) of ductwork between the fan and the intake grille.      7.2.1 Dwelling Unit Ventilation or Continuous Local Exhaust Fans.These fans shall be rated for sound at a maximum of 1.0 sone.      7.2.2 Demand-Controlled Local Exhaust Fans.Bathroom exhaust fans used to comply with Section 5.2 shall be rated for sound at a maximum of 3 sone, Kitchen exhaust fans used to comply with Section 5.2 shall be rated for sound at a maximum of 3 sone at one or more airflow settings greater than or equal to 100 cfm (47 L/s). Exceptions: 1.Fans with minimum airflow settings exceeding 400 cfm (189 L/s) need not comply. 2.Kitchen Range hoods may be rated for sound at the static pressure determined at working speed as specified in HVI 916 section 7. 03 7.3 Exhaust Ducts.      7.3.1 Multiple Exhaust Fans Using One Duct.Exhaust fans in separate dwelling units shall not share a common exhaust duct. If more than one of the exhaust fans in a dwelling unit shares a common exhaust duct, each fan shall be equipped with a back draft damper to prevent the recirculation of exhaust air from one room to another through the exhaust ducting system.      7.3.2 Single Exhaust Fan Ducted to Multiple Inlets.Where exhaust inlets are commonly ducted across multiple dwelling units, one or more exhaust fans located downstream of the exhaust inlets shall be designed and intended to run continuously, or a system of one or more backdraft dampers shall be installed to isolate each dwelling unit from the common duct when the fan is not running. 04 7.4 Supply Ducts.Where supply outlets are commonly ducted across multiple dwelling units, one or more supply fans located upstream of the supply inlets shall be designed and intended to run continuously, or a system of one or more backdraft dampers shall be installed to isolate each dwelling unit from the common duct when the fan is not running. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 5 of 5) Registration Number: 422-P010021377A-000-001-M27005A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:14:32 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M32036A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:53 CERTIFICATE OF INSTALLATION CF2R-MCH-32-H Local Mechanical Exhaust (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Equation and table numbering on this form corresponds to the numbering for that information in the published ANSI/ASHRAE Standard 62.2-2010 A. Local Mechanical Exhaust - General Information 01 Dwelling Unit Name Single Family Dwelling 02 Building Type Single family attached 03 Total Kitchen Floor Area 2000 04 Kitchen Average Ceiling Height 10 05 Kitchen Total Conditioned Volume 20000 06 Kitchen Type Non-Enclosed NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-32-H Local Mechanical Exhaust (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M32036A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:53 B. Local Mechanical Exhaust System - Fan selection and duct design criteria for compliance Local mechanical exhaust fans shall be installed in each kitchen and bathroom. Delivered local ventilation rates: •All local ventilation rates have been measured using a flow hood, flow grid, or other airflow measuring device and meet the requirements of 62.2 Tables 5.1 or 5.2. OR •The airflow rating at a pressure of 0.25 in. w.c. of a certified fan is assumed because the local ventilation system duct sizing meets the prescriptive requirements of 62.2 Table 5.3, or manufacturer's design criteria. Table 5.1 Intermittent Local Ventilation Exhaust Airflow Rates Application Airflow Notes Kitchen 100 cfm Vented range hood (including appliance-range hood combinations) required if exhaust fan flow is less than 5 ACH. Bathroom 50 cfm Table 5.2 Continuous Local Ventilation Exhaust Airflow Rates Application Airflow Notes Kitchen 5 ACH Based on Kitchen volume. Bathroom 20 cfm Table 5.3 Prescriptive Duct Sizing Requirements Duct Type Flex Duct Smooth Duct Fan Rating cfm @ 0.25 in. w.g.50 80 100 125 50 80 100 125 Maximum Allowable Duct Length (ft) Diameter, (in)Flex Duct Smooth Duct 3 X X X X 5 X X X 4 70 3 X X 105 35 5 X 5 NL 70 35 20 NL 135 85 55 6 NL NL 125 95 NL NL NL 145 7 and above NL NL NL NL NL NL NL NL This table assumes no elbows. Deduct 15 ft of allowable duct length for each turn, elbow, or fitting. Interpolation and extrapolation in 62.2 Table 5.3 is not allowed. For airflow values not listed, use the next higher value. This table is not applicable for airflow > 125 cfm. NL = no limit on duct length of this size. X = not allowed, any length of duct of this size with assumed turns, elbows, fittings will exceed the rated pressure drop. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-32-H Local Mechanical Exhaust (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M32036A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:53 C. Kitchen Exhaust Systems 01 02 03 04 05 06 07 08 09 10 11 System Name Manufactur er Name System Type HVI or AHAM Directory Listed Model Number HVI or AHAM Directory Listed Rated Airflow HVI or AHAM Directory Listed Sound Rating Minimum Airflow (defaults to rated airflow) Operation Schedule Required Minimum Ventilation Rate (if demand controlled) Maximum Sound Rating Compliance Statement 1 ALTRA Vented Range Hood 56544 654648 .9 200 Demand Control 100 3 sone Complies D. Continuous Kitchen Exhaust 01 Total Continuous Ventilation Airflow n/a 02 Required Minimum Continuous Ventilation Airflow n/a 03 Compliance Statement n/a E. Other Requirements 01 Demand control exhaust system shall be provided with at least one of the following: 1.A readily accessible occupant-controlled on-off control. 2.An automatic control that does not impeded occupant on control. 02 Nonenclosed kitchens shall be provided with a demand-controlled mechanical exhaust system. 03 Each continuous mechanical exhaust system shall be provided with a readily accessible manual on-off control. (Multifamily dwellings are exempt from readily accessible requirement. ) 04 Continuous mechanical exhaust systems shall be designed to operate during all occupiable hours. 05 Exhaust fans in separate dwelling units shall not share a common exhaust duct. Exhaust inlets from more than one dwelling unit may be served by a single exhaust fan downstream of all the exhaust inlets if the fan is designated and intended to run continuously or if each inlet is equipped with a back-draft damper to prevent cross-contamination when the fan is not running. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-32-H Local Mechanical Exhaust (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M32036A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:53 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20030A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:25:56 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Location or Area Served Master 03 Indoor Unit Name or Description of Area Served Master 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20030A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:25:56 B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1391 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.03 10 Calculated Target Allowable Duct Leakage (cfm)36 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)36 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20030A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:25:56 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23035A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:53 CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Description of Area Served Master 03 Indoor Unit Name Master 04 System Installation Type New 05 Nominal Cooling Capacity (tons)3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23035A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:53 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1050 03 Actual System Airflow Rate Measurement (cfm)1804 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Installation. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23035A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:53 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22052A-0000 Registration Date/Time: 2023-04-24   13:59:55 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:58 CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 11 02 System Location or Area Served Master 03 Indoor Unit Name or Description of Area Served Master 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 214 02 Actual Tested Airflow from MCH-23 (cfm)1804 03 Required Fan Efficacy (Watts/cfm)0.31 04 Actual Fan Efficacy (Watts/cfm)0.12 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22052A-0000 Registration Date/Time: 2023-04-24   13:59:55 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:58 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22052A-0000 Registration Date/Time: 2023-04-24   13:59:55 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:58 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25029A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:59:52 CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Each system requiring refrigerant charge verification will be documented on a separate certificate. 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Location or Area Served Master 03 Condenser (or package unit) Make or Brand 04 Condenser (or package unit) Model Number 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) Serial Number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer). This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling MCH-25b - Refrigerant Charge Verification - Subcooling Method NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 2 of 5) Registration Number: 422-P010021377A-000-001-M25029A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:59:52 B. Metering Device Verification Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2023-04-04 02 Date of Digital Thermocouple Calibration 2023-04-04 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Master 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 3 of 5) Registration Number: 422-P010021377A-000-001-M25029A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:59:52 F. Data Collection and Calculations Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2. 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure ( °F) 70 02 Measured Condenser Air Entering Dry-Bulb Temperature (Tcondenser, db) 75 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method 04 Measured Liquid Line Temperature (Tliquid) ( °F)102.3 05 Measured Liquid Line Pressure (Pliquid) (psig)256.3 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 ( °F) 111.2 07 Measured Subcooling (Line F06 - Lilne F04 ( °F)8.9 08 Target Subcooling from Manufacturer ( °F)8 09 Compliance Statement:System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) ( °F)60.3 02 Measured Suction Line Pressure (Psuction) (psig)105.4 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 ( °F) 51.2 04 Measured Superheat (Line G01- Line G03) ( °F)9.1 05 Measured Superheat (Line G04) is between 4 °F and 25 °F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement Metering device verification passes MCH-25d - Refrigeration Charge Verification - Fault Indicator Display (FID) H. Fault Indicator Display This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 4 of 5) Registration Number: 422-P010021377A-000-001-M25029A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:59:52 I. Fault Indicator Display Additional Requirements This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 5 of 5) Registration Number: 422-P010021377A-000-001-M25029A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:59:52 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26049A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:53 CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Description of Area Served Master 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 16546464 09 Does the directory used to certify product performance require a specific air handler, furnace or fan coil make and model? No 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from nameplate of installed system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 11 Master Master HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26049A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:53 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 11 Master Master HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 59000 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating Output at 17 Degrees F 49500 04 Installed Heating Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26049A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:53 G. Verified Heat Pump HSPF 01 Required minimum HSPF 11 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil This section does not apply to this project. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. J. Verified Space Conditioning System TXV 01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26049A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:53 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20009A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:33 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Location or Area Served Bedrooms 03 Indoor Unit Name or Description of Area Served Bedrooms 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20009A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:33 B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1000 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)60 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)0.1 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20009A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:33 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23011A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:14:34 CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Description of Area Served Bedrooms 03 Indoor Unit Name Bedrooms 04 System Installation Type New 05 Nominal Cooling Capacity (tons)2 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23011A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:14:34 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)700 03 Actual System Airflow Rate Measurement (cfm)1074 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Installation. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23011A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:14:34 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22013A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:36 CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 22 02 System Location or Area Served Bedrooms 03 Indoor Unit Name or Description of Area Served Bedrooms 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 2 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 100 02 Actual Tested Airflow from MCH-23 (cfm)1074 03 Required Fan Efficacy (Watts/cfm)0.31 04 Actual Fan Efficacy (Watts/cfm)0.09 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22013A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:36 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22013A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:36 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25027A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Each system requiring refrigerant charge verification will be documented on a separate certificate. 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Location or Area Served Bedrooms 03 Condenser (or package unit) Make or Brand 04 Condenser (or package unit) Model Number 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) Serial Number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer). This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling MCH-25b - Refrigerant Charge Verification - Subcooling Method NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 2 of 5) Registration Number: 422-P010021377A-000-001-M25027A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 B. Metering Device Verification Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2023-04-04 02 Date of Digital Thermocouple Calibration 2023-04-04 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Bedrooms 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 3 of 5) Registration Number: 422-P010021377A-000-001-M25027A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 F. Data Collection and Calculations Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2. 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure ( °F) 77 02 Measured Condenser Air Entering Dry-Bulb Temperature (Tcondenser, db) 95 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method 04 Measured Liquid Line Temperature (Tliquid) ( °F)103.4 05 Measured Liquid Line Pressure (Pliquid) (psig)241.2 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 ( °F) 112.4 07 Measured Subcooling (Line F06 - Lilne F04 ( °F)9 08 Target Subcooling from Manufacturer ( °F)8 09 Compliance Statement:System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) ( °F)60.4 02 Measured Suction Line Pressure (Psuction) (psig)108.6 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 ( °F) 50.4 04 Measured Superheat (Line G01- Line G03) ( °F)10 05 Measured Superheat (Line G04) is between 4 °F and 25 °F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement Metering device verification passes MCH-25d - Refrigeration Charge Verification - Fault Indicator Display (FID) H. Fault Indicator Display This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 4 of 5) Registration Number: 422-P010021377A-000-001-M25027A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 I. Fault Indicator Display Additional Requirements This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 5 of 5) Registration Number: 422-P010021377A-000-001-M25027A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26032A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:25:56 CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Description of Area Served Bedrooms 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 1254879 09 Does the directory used to certify product performance require a specific air handler, furnace or fan coil make and model? Non-furnace air-handling unit 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from nameplate of installed system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 22 Bedrooms Bedrooms HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26032A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:25:56 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 22 Bedrooms Bedrooms HP Coil CARRIER 25VA436A00 3 CARRIER 25VA436A00 3 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 59000 02 Installed Heating BTU Output at 47 Degrees F 59000 03 Required Heating Output at 17 Degrees F 49500 04 Installed Heating Output at 17 Degrees F 49500 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26032A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:25:56 G. Verified Heat Pump HSPF 01 Required minimum HSPF 11 02 Installed HSPF 11 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil 01 If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of Certified Product Performance. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. J. Verified Space Conditioning System TXV 01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26032A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:25:56 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20003A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Location or Area Served Kids room 03 Indoor Unit Name or Description of Area Served Kids room 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20003A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)60 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)40 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20003A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23006A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:14:32 CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Description of Area Served Kids room 03 Indoor Unit Name Kids room 04 System Installation Type New 05 Nominal Cooling Capacity (tons)3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23006A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:14:32 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1050 03 Actual System Airflow Rate Measurement (cfm)1089 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Installation. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23006A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:14:32 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22008A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:33 CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 33 02 System Location or Area Served Kids room 03 Indoor Unit Name or Description of Area Served Kids room 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 100 02 Actual Tested Airflow from MCH-23 (cfm)1089 03 Required Fan Efficacy (Watts/cfm)0.22 04 Actual Fan Efficacy (Watts/cfm)0.09 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22008A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:33 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22008A-0000 Registration Date/Time: 2023-04-24   13:14:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:33 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25031A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Each system requiring refrigerant charge verification will be documented on a separate certificate. 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Location or Area Served Kids room 03 Condenser (or package unit) Make or Brand 04 Condenser (or package unit) Model Number 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) Serial Number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer). This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling MCH-25b - Refrigerant Charge Verification - Subcooling Method NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 2 of 5) Registration Number: 422-P010021377A-000-001-M25031A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 B. Metering Device Verification Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2023-04-04 02 Date of Digital Thermocouple Calibration 2023-04-04 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Kids room 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 3 of 5) Registration Number: 422-P010021377A-000-001-M25031A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 F. Data Collection and Calculations Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2. 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure ( °F) 70 02 Measured Condenser Air Entering Dry-Bulb Temperature (Tcondenser, db) 76 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method 04 Measured Liquid Line Temperature (Tliquid) ( °F)102.6 05 Measured Liquid Line Pressure (Pliquid) (psig)256.3 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 ( °F) 110.5 07 Measured Subcooling (Line F06 - Lilne F04 ( °F)7.9 08 Target Subcooling from Manufacturer ( °F)8 09 Compliance Statement:System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) ( °F)60.3 02 Measured Suction Line Pressure (Psuction) (psig)102.3 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 ( °F) 52 04 Measured Superheat (Line G01- Line G03) ( °F)8.3 05 Measured Superheat (Line G04) is between 4 °F and 25 °F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement Metering device verification passes MCH-25d - Refrigeration Charge Verification - Fault Indicator Display (FID) H. Fault Indicator Display This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 4 of 5) Registration Number: 422-P010021377A-000-001-M25031A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 I. Fault Indicator Display Additional Requirements This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 5 of 5) Registration Number: 422-P010021377A-000-001-M25031A-0000 Registration Date/Time: 2023-04-24   13:25:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:25:56 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26033A-0000 Registration Date/Time: 2023-04-24   13:27:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:27:39 CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Description of Area Served Kids room 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 16546464 09 Does the directory used to certify product performance require a specific air handler, furnace or fan coil make and model? Non-furnace air-handling unit 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from nameplate of installed system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 33 Kids room Kids room HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26033A-0000 Registration Date/Time: 2023-04-24   13:27:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:27:39 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 33 Kids room Kids room HP Coil carrier 25VANA436A 00 CARRIER 25VANA436A 00 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 34600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating Output at 17 Degrees F 32600 04 Installed Heating Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26033A-0000 Registration Date/Time: 2023-04-24   13:27:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:27:39 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10.5 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil 01 If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of Certified Product Performance. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. J. Verified Space Conditioning System TXV 01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26033A-0000 Registration Date/Time: 2023-04-24   13:27:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:27:39 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20002A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 44 02 Space Conditioning System Location or Area Served Kitchen 03 Indoor Unit Name or Description of Area Served Kitchen 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?No, credit is not taken 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20a - Completely New Duct System B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)60 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)41 12 Compliance Statement System passes leakage test NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20002A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. 02 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 03 All supply and return register boots were sealed to the drywall. 04 Building cavities were not used as plenums or platform returns in lieu of ducts. 05 If cloth backed tape was used it was covered with Mastic and draw bands. 06 All connection points between the air handler and the supply and return plenums are completely sealed. Visual Inspection at Final Construction Stage (applicable if system was tested at rough-in). After installing the interior finishing wall and verifying that the above rough-in tests was completed, the following procedure must be performed 07 For all supply and return registers, verify that the spaces between the register boot and the interior finishing wall are properly sealed. 08 If the house rough-in duct leakage test was conducted without an air handler installed, inspect the connection points between the air handler and the supply and return plenums to verify that the connection points are properly sealed. 09 Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20002A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23048A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:53 CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 44 02 Space Conditioning System Description of Area Served Kitchen 03 Indoor Unit Name Kitchen 04 System Installation Type New 05 Nominal Cooling Capacity (tons)5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23048A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:53 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1750 03 Actual System Airflow Rate Measurement (cfm)1845 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Installation. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23048A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:53 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22050A-0000 Registration Date/Time: 2023-04-24   13:59:54 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:54 CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 44 02 System Location or Area Served Kitchen 03 Indoor Unit Name or Description of Area Served Kitchen 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 321 02 Actual Tested Airflow from MCH-23 (cfm)1845 03 Required Fan Efficacy (Watts/cfm)0.18 04 Actual Fan Efficacy (Watts/cfm)0.17 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22050A-0000 Registration Date/Time: 2023-04-24   13:59:54 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:54 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22050A-0000 Registration Date/Time: 2023-04-24   13:59:54 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:54 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26056A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 44 02 Space Conditioning System Description of Area Served Kitchen 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 16564654 09 Does the directory used to certify product performance require a specific air handler, furnace or fan coil make and model? No 10 Does the directory used to certify product performance require a time delay relay (+TDR)? No 11 Does the directory used to certify product performance require a TXV (+TXV)? No B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from nameplate of installed system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 44 Kitchen Kitchen HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26056A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 44 Kitchen Kitchen HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 18.6 02 Installed SEER 18.6 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 27600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating Output at 17 Degrees F 26200 04 Installed Heating Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26056A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil This section does not apply to this project. I. Verified Space Conditioning System Time Delay Relay This section does not apply to this project. J. Verified Space Conditioning System TXV This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26056A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20012A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:34 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 55 02 Space Conditioning System Location or Area Served Living Room 03 Indoor Unit Name or Description of Area Served Living Room 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20012A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:34 B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)4.99 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)99.8 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)33 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20012A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:34 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23016A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:52 CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 55 02 Space Conditioning System Description of Area Served Living Room 03 Indoor Unit Name Living Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons)5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23016A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:52 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1750 03 Actual System Airflow Rate Measurement (cfm)1802 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Installation. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23016A-0000 Registration Date/Time: 2023-04-24   13:59:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:52 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22054A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:57 CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 55 02 System Location or Area Served Living Room 03 Indoor Unit Name or Description of Area Served Living Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 233 02 Actual Tested Airflow from MCH-23 (cfm)1802 03 Required Fan Efficacy (Watts/cfm)0.24 04 Actual Fan Efficacy (Watts/cfm)0.13 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22054A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:57 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22054A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:57 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25061A-0000 Registration Date/Time: 2023-04-24   14:01:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:01:45 CERTIFICATE OF INSTALLATION CF2R-MCH-25-E Refrigerant Charge Verification (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Each system requiring refrigerant charge verification will be documented on a separate certificate. 01 Space Conditioning System Identification or Name HVAC System 55 02 Space Conditioning System Location or Area Served Living Room 03 Condenser (or package unit) Make or Brand 04 Condenser (or package unit) Model Number 05 Nominal Cooling Capacity (tons) of Condenser 4.99 06 Condenser (or package unit) Serial Number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer). This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.New package unit factory charge 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status HERS verification of refrigerant charge is not required MCH-25f - Refrigerant Charge Verification - New Package Unit With Factory Charge NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-E Refrigerant Charge Verification (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M25061A-0000 Registration Date/Time: 2023-04-24   14:01:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:01:45 B. Measurement Access Hole (MAH) Verification Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 C. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Living Room 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: D. Verification of New Package Unit Factory Charge Note: There is no HERS verification requirement for the MCH-25f . The Enforcement Agency has responsibility for verification of the MCH-25f. 01 The responsible person's signature on this document affirms that this new package unit has correct refrigerant charge as provided by the manufacturer prior to shipment from the factory, and no modifications have been made to this packaged unit that would result in a change to the amount of refrigerant in the unit. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-E Refrigerant Charge Verification (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M25061A-0000 Registration Date/Time: 2023-04-24   14:01:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:01:45 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26044A-0000 Registration Date/Time: 2023-04-24   14:01:44 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   14:01:45 CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 55 02 Space Conditioning System Description of Area Served Living Room 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 31655646465 09 Does the directory used to certify product performance require a specific air handler, furnace or fan coil make and model? No 10 Does the directory used to certify product performance require a time delay relay (+TDR)? No 11 Does the directory used to certify product performance require a TXV (+TXV)? No B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from nameplate of installed system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 55 Living Room Living Room HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26044A-0000 Registration Date/Time: 2023-04-24   14:01:44 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   14:01:45 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 55 Living Room Living Room HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 34600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating Output at 17 Degrees F 32600 04 Installed Heating Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26044A-0000 Registration Date/Time: 2023-04-24   14:01:44 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   14:01:45 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10.5 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil This section does not apply to this project. I. Verified Space Conditioning System Time Delay Relay This section does not apply to this project. J. Verified Space Conditioning System TXV This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26044A-0000 Registration Date/Time: 2023-04-24   14:01:44 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   14:01:45 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20014A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:37 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 66 02 Space Conditioning System Location or Area Served Great Room 03 Indoor Unit Name or Description of Area Served Great Room 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20014A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:37 B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)5 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)100 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)60 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20014A-0000 Registration Date/Time: 2023-04-24   13:14:34 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:37 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23045A-0000 Registration Date/Time: 2023-04-24   13:59:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:40 CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 66 02 Space Conditioning System Description of Area Served Great Room 03 Indoor Unit Name Great Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons)5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23045A-0000 Registration Date/Time: 2023-04-24   13:59:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:40 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1750 03 Actual System Airflow Rate Measurement (cfm)1825 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Installation. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23045A-0000 Registration Date/Time: 2023-04-24   13:59:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:59:40 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22046A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:53 CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 66 02 System Location or Area Served Great Room 03 Indoor Unit Name or Description of Area Served Great Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 265 02 Actual Tested Airflow from MCH-23 (cfm)1825 03 Required Fan Efficacy (Watts/cfm)0.28 04 Actual Fan Efficacy (Watts/cfm)0.15 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22046A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:53 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22046A-0000 Registration Date/Time: 2023-04-24   13:59:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:59:53 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25062A-0000 Registration Date/Time: 2023-04-24   14:01:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:01:45 CERTIFICATE OF INSTALLATION CF2R-MCH-25-E Refrigerant Charge Verification (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Each system requiring refrigerant charge verification will be documented on a separate certificate. 01 Space Conditioning System Identification or Name HVAC System 66 02 Space Conditioning System Location or Area Served Great Room 03 Condenser (or package unit) Make or Brand 04 Condenser (or package unit) Model Number 05 Nominal Cooling Capacity (tons) of Condenser 5 06 Condenser (or package unit) Serial Number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer). This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.New package unit factory charge 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status HERS verification of refrigerant charge is not required MCH-25f - Refrigerant Charge Verification - New Package Unit With Factory Charge NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-E Refrigerant Charge Verification (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M25062A-0000 Registration Date/Time: 2023-04-24   14:01:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:01:45 B. Measurement Access Hole (MAH) Verification Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 C. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Great Room 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: D. Verification of New Package Unit Factory Charge Note: There is no HERS verification requirement for the MCH-25f . The Enforcement Agency has responsibility for verification of the MCH-25f. 01 The responsible person's signature on this document affirms that this new package unit has correct refrigerant charge as provided by the manufacturer prior to shipment from the factory, and no modifications have been made to this packaged unit that would result in a change to the amount of refrigerant in the unit. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-E Refrigerant Charge Verification (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M25062A-0000 Registration Date/Time: 2023-04-24   14:01:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:01:45 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26057A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 66 02 Space Conditioning System Description of Area Served Great Room 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 231654654 09 Does the directory used to certify product performance require a specific air handler, furnace or fan coil make and model? Non-furnace air-handling unit 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from nameplate of installed system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 66 Great Room Great Room HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26057A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 66 Great Room Great Room HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 34600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating Output at 17 Degrees F 32600 04 Installed Heating Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26057A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10.5 02 Installed HSPF 16 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil 01 If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of Certified Product Performance. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. J. Verified Space Conditioning System TXV 01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26057A-0000 Registration Date/Time: 2023-04-24   13:59:56 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20190501 Report Generated: 2023-04-24   13:59:57 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable): NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-B02004A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 1 of 5) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Design Dwelling Unit Water Heating Systems Information This table reports the water heating system features that were specified on the registered CF1R compliance document for this project. 01 02 03 04 05 06 07 08 09 10 Dwelling Unit Name Water Heating System ID or Name Water Heating System Type Water-Heater Type # of Like (or Identical) Water Heaters in System Fuel Type Rated Input Type Rated Input Value Dwelling Unit DHW System Distribution Type Compact Distrib. Single Family Dwelling DHW Sys 1 Domestic Hot Water (DHW) Commercial Storage 2 Natural Gas Btu/Hr 85000.00 Standard Distribution System None B. Installed Dwelling Unit Water Heating Systems Information This table reports the water heating system features that were installed in this project. 01 02 03 04 05 06 07 08 09 10 Dwelling Unit Name Water Heating System ID or Name Water Heating System Type Water-Heater Type # of Like (or Identical) Water Heaters in System Fuel Type Rated Input Type Rated Input Value Dwelling Unit DHW System Distribution Type Compact Distrib. Single Family Dwelling DHW Sys 1 Domestic Hot Water (DHW)Commercial Storage 2 Natural Gas Btu/Hr 85000 Standard Distribution System None C. Design Dwelling Unit Water Heating Efficiency Information This table reports the water heater(s) efficiency features specified on the registered CF1R compliance document for this project. 01 02 03 04 05 06 07 Water Heating System ID or Name Heating Efficiency Type Heating Efficiency Value Standby Loss (%)Exterior Insul. R-Value Water Heater Storage Volume (gal)Tank Location DHW Sys 1 TE 0.81 0.02 0 75.00 n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 2 of 5) Registration Number: 422-P010021377A-000-001-B02004A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 D. Installed Dwelling Unit Water Heating Efficiency Information This table reports the water heating system features that were installed in this project. 01 02 03 04 05 06 07 Water Heating System ID or Name Heating Efficiency Type Heating Efficiency Value Standby Loss (%)Exterior Insul. R-Value Water Heater Storage Volume (gal)Tank Location DHW Sys 1 TE 0.81 0.02 0 75 n/a E. Installed Water Heater Manufacturer Information 01 02 03 Water Heating System ID or Name Manufacturer Model Number DHW Sys 1 ao smith 65481255 DHW Sys 1 ao smith 65481255 F. Mandatory Measures For All Domestic Hot Water Distribution Systems 01 Equipment shall meet the applicable requirements of the Appliance Efficiency Regulations (Section 110.3(b)1). 02 Unfired storage tanks are insulated with an external R-12 or combination of R-16 internal and external Insulation. (Section 110.3(c)4). NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 3 of 5) Registration Number: 422-P010021377A-000-001-B02004A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 F. Mandatory Measures For All Domestic Hot Water Distribution Systems 03 All domestic hot water pipes shall be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions shall have a minimum insulation wall thickness of 1 inch or a minimum insulation R-value of 7.7 (RA4.4.1) •The first 5 feet (1.5 meters) of cold water pipes from the storage tank. •All piping with a nominal diameter of 3/4 inch (19 millimeter) and less than 1 inch.. •All hot water pipes from the heating source to the kitchen fixtures. •Piping from the heating source to storage tank or between tanks. •All piping associated with a recirculation system. •All underground piping. •Insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. •Piping that penetrates framing members shall not be required to have pipe insulation for the distance of the framing penetration. •Piping that penetrates metal framing shall use grommets, plugs, wrapping or other insulating material to assure that no contact is made with the metal framing. Insulation shall butt securely against all framing members. •Piping installed in interior or exterior walls that is surrounded on all sides by at least 1 inch (2.5 cm) of insulation. •Piping installed in crawl space with a minimum of 1 inch (2.5 cm) of crawl space insulation above and below. •Piping installed in attics with a minimum of 4 inches (10 cm) of attic insulation on top •Piping insulation shall fit tightly and all elbows and tees shall be fully insulated. 04 For Gas or Propane Water Heaters: Ensure the following are installed (Section 150.0(n)) 1.A dedicated 120V, 20A electrical receptacle connected to the electrical panel with a 120/240V 3 conductor, 10AWG copper branch circuit, within 3 feet from the water heater and accessible with no obstructions 1.The conductor shall be labeled with the word "Spare" on both ends; and 2.A reserved single pole circuit breaker space next to the circuit breaker next to the branch circuit labeled "Future" 240V shall be provided. 2.A Category III or IV vent, or a Type B vent with straight pipe between outside and water heater 3.A condensate drain no more than 2 inches higher than the base on water heater for natural draining 4.A gas supply line with capacity of at least 200,000 Btu/Hr The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Compact Hot Water Distribution (CHWDS) RA4.4.6 This section does not apply to this project. H. Parallel Piping Requirements (PP) (RA4.4.4) This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 4 of 5) Registration Number: 422-P010021377A-000-001-B02004A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 I. Point of Use Requirements (POU) (RA4.4.5) This section does not apply to this project. J. Mandatory Requirements For All Recirculation Systems (RA4.4.7) This section does not apply to this project. K. Recirculation Non-Demand Controls Requirements (R-ND) (RA4.4.8) This section does not apply to this project. L. Demand Recirculation Manual Control (R-DRmc) (RA4.4.9)/ Sensor Control Requirements (RDRsc) (RA4.4.10) This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 5 of 5) Registration Number: 422-P010021377A-000-001-B02004A-0000 Registration Date/Time: 2023-04-24   13:14:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:14:32 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-P01063A-0000 Registration Date/Time: 2023-04-24   14:01:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:01:46 CERTIFICATE OF INSTALLATION CF2R-PVB-01-E Photovoltaic Systems (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. General Information 01 Project Location (City)La Quinta 02 Building type Single family 03 Climate Zone 15 04 Method of Compliance:Performance 05 Qualifying Exceptions No PV - limited solar access (Trigger CF2R-SRA-01)06 Community Solar n/a B. Design Photovoltaic Systems Information This section does not apply to this project. C. Installed Photovoltaic Systems Information This section does not apply to this project. D. Shading Requirement This section does not apply to this project. E. Solar Access Verification 01 The installer shall provide documentation that demonstrates the shading condition of the actual installation of the PV module is consistent with the shading requirement in Table D. The verification must be done by measurements from an approved solar assessment tool or other CEC approved alternative methods. The satellite, drone or other digital image of the obstructions that cast shadows on the PV array must be created and dated after the installation of the photovoltaic system. If the image is dated before the installation, then additional on-site pictures must be attached to clearly show that the installed system matches the system modeled in the solar assessment report. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. F. System Monitoring Requirements This section does not apply to this project. G. Qualifying Exception Requirement Limited Solar Access The installer shall provide documentation of the roof area limitations that justify the exception. Documentation may include roof plans, aerial photos, satellite images, 3D model, or other documentation that clearly shows the available roof areas that meet the solar access requirements. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PVB-01-E Photovoltaic Systems (Page 2 of 3) Registration Number: 422-P010021377A-000-001-P01063A-0000 Registration Date/Time: 2023-04-24   14:01:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:01:46 H. SMUD Solar Share Program This section does not apply to this project. I. Compliance Statement 01 Pass - dwelling does comply with the Photovoltaic System requirements NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PVB-01-E Photovoltaic Systems (Page 3 of 3) Registration Number: 422-P010021377A-000-001-P01063A-0000 Registration Date/Time: 2023-04-24   14:01:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:01:46 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-R01065A-0000 Registration Date/Time: 2023-04-24   14:01:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:01:46 CERTIFICATE OF INSTALLATION CF2R-SRA-01-E Solar Ready Buildings - New Construction (Page 1 of 2) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. General Information Only use this form if the newly constructed do not have a PV system installed. Do not use this form to show solar ready compliance for hotel/motel occupancies and high-rise multifamily buildings with ten stories or fewer and all other nonresidential buildings with three stories or fewer. Instead, use form NRCC-SRA-01-E 01 Building Type Single family 02 Method of Compliance Permanently installed solar water heating system B. Building Meets the Solar Ready Requirements This section does not apply to this project. C. Residence not in an Applicable Subdivision This section does not apply to this project. D. Permanently Installed Solar Water Heating System 01 Solar Water Heating System Rating OG-300 02 Solar savings fraction of the proposed solar water heating system 0.5 03 Compliance Statement System complies The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. E. Smart Thermostats and Alternative Efficiency Measure (Single Family) This section does not apply to this project. F. Smart Thermostats and Alternative Efficiency Measure (Multifamily) This section does not apply to this project. G. Roof is Designed for Vehicle Traffic or Parking or for Heliport (Applies to Low-rise Multifamily only) This section does not apply to this project. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-SRA-01-E Solar Ready Buildings - New Construction (Page 2 of 2) Registration Number: 422-P010021377A-000-001-R01065A-0000 Registration Date/Time: 2023-04-24   14:01:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:01:46 Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Signature Date: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4.I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Butch White Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Breeze Air Conditioning LLC Position With Company (Title): Contractor/Installer Address: 75-145 Street Charles Place CSLB License: 1045015 City/State/Zip: Palm Desert CA 92211 Phone: (760) 346-0855 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-E21021A-E21A Registration Date/Time: 2023-04-24   13:33:21 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:21 CERTIFICATE OF VERIFICATION CF3R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 1 of 6) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Air Barrier Materials 01 A continuous sealed exterior air barrier is required in all thermal envelope assemblies to limit air movement between unconditioned/ outside spaces and conditioned/ inside spaces, and must comply using one of the following methods: 1.Using individual materials that have an air permeance not exceeding 0.004 cfm/ft2 under a pressure differential of 0.3 in. w.g. (1.57 pcf) (0.02 L/s.m2 at 75 pa) when tested in accordance with ASTM E2178; or 2.Using assemblies of materials and components that have an average air leakage not to exceed 0.04 cfm/ft2 under a pressure differential of 0.3 in. w.g. (1.57 pcf) (0.2 L/s.m2 at 75 pa) when tested in accordance with ASTM E2357, ASTM E1677, ASTM E1680, or ASTM E283; or 3.Testing the complete building and demonstrating that the air leakage rate of the building envelope does not exceed 0.40 cfm/ft 2 under a pressure differential of 0.3 in. w.g. (1.57 pcf) (2.0 L/s.m2 at 75 pa) when tested in accordance with ASTM E779 or an equivalent approved method. 02 Method of Compliance Method 1 (Individual Materials) 03 Verification Status Pass - all applicable requirements are met. 04 Correction Notes Note:      SPF insulation is an acceptable air barrier and sealant when installed to a minimum thickness of 2 inches for closed cell and 5.5 inches for open cell, except where not allowed by manufacturer (e.g. flues, vents, can lights, etc). The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. B. Raised Floor Adjacent to Unconditioned Space or Separate Dwelling Units 01 All gaps in the raised floor are sealed. 02 All chases sealed at floor level using a sealed hard cover. 03 All holes (e.g. for plumbing and electrical wires) that penetrate the floor or bottom plates of walls are sealed. 04 Subfloor sheathing is glued or sealed at all panel edges to create a continuous air tight subfloor air barrier. 05 Verification Status Pass - all applicable requirements are met. 06 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. C. Walls Adjacent to Unconditioned Space 01 All penetrations through the exterior wall air barrier are sealed to provide an air-tight envelope to unconditioned spaces such as the outdoors, attic, garage and crawl space. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 2 of 6) Registration Number: 422-P010021377A-000-001-E21021A-E21A Registration Date/Time: 2023-04-24   13:33:21 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:21 C. Walls Adjacent to Unconditioned Space 02 Exterior wall air barrier is sealed to the top plate and bottom plate in each stud bay. 03 All electrical boxes, including knockouts that penetrate the air barrier to unconditioned space are sealed. 04 All openings in top and bottom plate, including all interior and exterior walls, to unconditioned space are sealed; such as holes drilled for electrical and plumbing. 05 Exterior bottom plates (all stories) are sealed to the floor. 06 All gaps around windows and doors are sealed. The sealant used follows manufacturer specifications. 07 Rim joist gaps and openings are fully sealed. 08 Fan exhaust duct outlet/ damper at the exterior wall are sealed. 09 Knee walls have solid and sealed blocking at the bottom, top, left and right sides to prevent air movement into insulation. 10 Verification Status Pass - all applicable requirements are met. 11 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. D. Ceiling Air Barrier Adjacent to Unconditioned Space 01 There is a continuous air barrier at the ceiling level. All openings into walls, drops, chases or double walls are sealed. 02 All penetrations through the top plate of interior and exterior walls are sealed. 03 Fire sprinklers penetrating a ceiling air barrier shall be sealed to prevent air movement according to the manufacturer's instructions. 04 All fixtures cut into the ceiling air barrier (e.g. HVAC registers, electrical boxes, fire alarm boxes, exhaust fan housing, and recessed lighting fixtures) are sealed to the surrounding dry wall. If it is not possible to seal the fixture directly, a secondary air barrier shall be created around the fixture. 05 All installed recessed lighting fixtures that penetrate the ceiling to unconditioned space are rated to be Insulation Contact and Airtight (IC and AT) which allow direct contact with insulation. 06 All dropped ceiling areas are covered with hard covers that are sealed to the framing, or else the bottom and sides of dropped ceiling areas are all insulated and sealed as ceilings and walls as required on the Certificate of Compliance. 07 All vertical chases (e.g. HVAC ducts and plumbing) and soffits are sealed at the ceiling level. 08 Chimneys and flues require sheet metal flashing at the ceiling level. The flashing shall be sealed to the chimney/flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 09 Framing locations where air may move down into the walls from the attic (e.g. double walls, pocket doors, architectural bump-outs, etc) have a sealed hard cover to prevent air movement. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 3 of 6) Registration Number: 422-P010021377A-000-001-E21021A-E21A Registration Date/Time: 2023-04-24   13:33:21 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:21 D. Ceiling Air Barrier Adjacent to Unconditioned Space 10 Attic access forms an airtight seal between the conditioned space and unconditioned space. Vertical attic access requires mechanical compression using screws or latches. 11 Verification Status Pass - all applicable requirements are met. 12 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. E. Roof Air Barrier - Unvented Attics Adjacent to Unconditioned Space 01 There is a continuous air barrier at the roof deck and gable ends. 02 Chimneys and flues require sheet metal flashing at the roof deck. The flashing shall be sealed to the chimney/flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 03 All penetrations in the roof deck and gable ends for plumbing, electrical, etc. are sealed. 04 Verification Status Pass - all applicable requirements are met. 05 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. F. Conditioned Space Above Or Adjacent To Garage Air Barrier 01 All penetrations in the subfloor above the garage into conditioned space must follow the raised floor air barrier requirements above. 02 Infiltration between the space above the garage and subfloor is prevented by one of the following methods: •Seal all edges of garage ceiling (typically drywall) at the perimeter of the garage to create a continuous air tight surface between the garage and adjacent conditioned envelope. Seal all plumbing, electric and mechanical penetrations between the garage and the adjacent conditioned space. For an open-web truss, airtight blocking is added on four sides of the garage perimeter. Insulation can be placed on the garage ceiling. •Seal the band joist above the wall at the garage to conditioned space transition. Seal all subfloor seams and penetrations between the garage and adjacent conditioned space. Insulation must be placed in contact with the subfloor below the conditioned space. 03 Verification Status Pass - all applicable requirements are met. 04 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Cantilevered Floor Air Barrier 01 Airtight blocking is installed between joists where the wall rim joist would have been located in the absence of a cantilever. 02 Exterior sheathing is installed to the bottom of the cantilever so that there is a continuous air and weather barrier for the cantilever. The cantilevered joist must be insulated to the same R value as would be required for the subfloor prior to closing. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 4 of 6) Registration Number: 422-P010021377A-000-001-E21021A-E21A Registration Date/Time: 2023-04-24   13:33:21 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:21 G. Cantilevered Floor Air Barrier 03 Any gaps, cracks or penetrations in the air barrier of the cantilever are sealed. Recessed can lights in the cantilever are IC and AT and properly sealed to the sheathing. 04 Verification Status Pass - all applicable requirements are met. 05 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. H. Walls For Attached Porch, Attic, Double Wall Air Barrier 01 An exterior wall air barrier is required at the intersection of the porch and exterior wall when there is conditioned space on the other side. The exterior wall includes an air barrier where the attic attaches to the conditioned space. 02 Truss framing blocking is used at the top and bottom of each wall/ roof section. 03 Verification Status Pass - all applicable requirements are met. 04 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. I. Air Barriers in Multifamily Dwellings 01 Each dwelling unit must be sealed to stop air movement between dwelling units. Treat adjacent dwelling units as unconditioned space for air sealing. 02 All penetrations through the floor and ceiling of each dwelling unit are sealed including, electric and gas utilities, water pipes, drain pipes, fire protection service pipes, and communication wiring. 03 Elevator penthouse, mechanical penthouse, stairwell doors, roof access hatches, and plumbing stacks that separate conditioned and unconditioned space are all sealed. 04 Vertical chases for garbage chutes, elevator shafts, HVAC ducting and plumbing shall be treated as unconditioned space for sealing. 05 Common hallways shall be treated as unconditioned space for sealing. 06 Verification Status Pass - all applicable requirements are met. 07 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. J. Special Requirements for SIPs 01 SIPs are considered an air barrier when properly sealed at top, bottom, sides and all penetrations. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 5 of 6) Registration Number: 422-P010021377A-000-001-E21021A-E21A Registration Date/Time: 2023-04-24   13:33:21 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:21 J. Special Requirements for SIPs 02 Air barrier is continuous across all surfaces, including between SIPs and non-SIP sections. 03 Verification Status Pass - all applicable requirements are met. 04 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. K. Special Requirements for ICF 01 ICF sections are considered an air barrier when properly sealed at top, bottom, sides and all penetrations. 02 Air barrier is continuous across all surfaces, including between ICF and non-ICF sections. 03 Verification Status Pass - all applicable requirements are met. 04 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. L. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H QII - Air Infiltration Sealing - Framing Stage (Page 6 of 6) Registration Number: 422-P010021377A-000-001-E21021A-E21A Registration Date/Time: 2023-04-24   13:33:21 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:21 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-E22020A-E22A Registration Date/Time: 2023-04-24   13:33:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:19 CERTIFICATE OF VERIFICATION CF3R-ENV-22-H QII - Insulation Installation (Page 1 of 7) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Insulation Materials Installed 01 Roof Deck Insulation Material Installed n/a 02 Ceiling Insulation Material Installed n/a 03 Exterior Wall Insulation Material Installed Batt and Blanket 04 Raised Floor Insulation Material Installed n/a 05 Slab Edge Insulation Material Installed n/a 06 Verification Status Pass - all applicable requirements are met. B. All Surfaces 01 Air barrier installation and preparation for insulation was done and verified prior to insulation being installed. 02 All surfaces between conditioned and unconditioned space are sealed and insulated to meet or exceed the levels specified on the Certificate of Compliance 03 All structural framing areas shall be insulated in a manner that resists thermal bridging through the assembly separating conditioned from unconditioned space. Structural bracing, tie-downs, and framing of steel, or specialized framing used to meet structural requirements of the CBC are allowed and must be insulated. These areas shall be called out on the building plans with diagrams and/ or specified design drawings indicating the R-value of insulation and fastening method to be used. 04 All insulation was installed according to the manufacturer's installation instructions. 05 Labels or specification/ data sheets for each insulation material shall be provided to the HERS rater. Loose-fill material includes insulation material bag labels or coverage charts. 06 Loose-fill insulation - the installed depth and density of insulation is verified in at least 6 random locations to ensure that the minimum thickness and installed density meet R-value specified on the Certificate of Compliance, and are consistent with the manufacturer's coverage chart. 07 If kraft paper faced insulation is used, paper is installed on the conditioned (warm in winter) side of surface. Paper must be in contact with air barrier to within 2" framing (stud, joists, etc.). 08 Verification Status Pass - all applicable requirements are met. 09 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. C. Raised Floor Adjacent to Unconditioned Space 01 Insulation is in full contact with the subfloor. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H QII - Insulation Installation (Page 2 of 7) Registration Number: 422-P010021377A-000-001-E22020A-E22A Registration Date/Time: 2023-04-24   13:33:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:19 C. Raised Floor Adjacent to Unconditioned Space 02 Insulation hangers are spaced at 18 inches or less. Insulation hangers do not compress insulation. 03 Netting, or mesh, can be used if the cavity under the floor is filled and in contact with the subfloor. 04 When daylight basements are adjacent to crawlspaces, if the basement is conditioned the walls adjacent to the crawlspace are insulated to the R-value listed on the Certificate of Compliance. This includes framed stem walls, and vertical concrete retaining walls. 05 If access to the crawlspace is from the conditioned area the raised floor includes an airtight insulated access hatch. Where possible locate crawl space access on the exterior. 06 Verification Status Pass - all applicable requirements are met. 07 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. D. Walls Adjacent to Unconditioned Space 01 Insulation quality was verified prior to the installation of the interior air barrier (typically gypsum board). 02 Loose-fill and batt insulation is in contact with all six sides of wall cavities (top, bottom, back, left, right, front [to be installed later]) with no gaps, voids or compression. Special Situation: Where framing depth is greater than required insulation thickness (e.g., double walls or framed bump-outs) a secondary air barrier shall be installed and in contact with the insulation, so that the insulation fills the cavity formed by the additional air barrier. 03 Insulation fits snuggly around obstructions (e.g., electrical boxes, plumbing and wiring) with no gaps, voids or compression. 04 Structural metal tie-downs and shear panels are insulated between exterior air barrier and metal. 05 Hard to access wall stud cavities, such as corner channels or wall intersections, are insulated to the proper R-value prior to the installation of exterior sheathing or exterior stucco lathe. 06 Insulation and interior air barrier are installed behind tub, shower, fireplace enclosures and stairwells to the R-value listed on the Certificate of Compliance when located against exterior walls. 07 All single-member window and door headers shall be insulated to a minimum of R-3 for a 2x4 framing, or equivalent width, and a minimum of R-5 for all other assemblies. No header insulation is required for single-member headers that are the same width as the wall, provided that the entire wall has at least R-2 insulation. 08 After insulation is installed: All insulated walls have interior and exterior air barriers, including kneewalls and walls of skylight wells. Exception: Rim joists. Interior air barrier (typically gypsum board) is sealed to top plate. 09 Verification Status Pass - all applicable requirements are met. 10 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. E. Ceiling Adjacent to Unconditioned Space 01 Insulation extends to the outside surface of the exterior wall. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H QII - Insulation Installation (Page 3 of 7) Registration Number: 422-P010021377A-000-001-E22020A-E22A Registration Date/Time: 2023-04-24   13:33:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:19 E. Ceiling Adjacent to Unconditioned Space 02 Insulation is in direct contact with the ceiling air barrier so there are no gaps, voids or compression. 03 Chimneys and flues (except zero clearance) have a sheet metal collar at the ceiling level to prevent contact with the insulation. The collar is at least as tall as the depth of the insulation. There is a minimum 1" clearance between the collar and the chimney/flue for double wall vent, and 6" for single wall vent, unless manufacturer's instructions require otherwise. The collar is sealed to the ceiling with high temperature sealant to prevent air leakage. The insulation is in contact with the sheet metal collar. 04 Recessed can lights penetrating the ceiling air barrier are covered with insulation to the depth needed to meet the ceiling R-value specified on the Certificate of Compliance. 05 External surfaces of steel studs, steel-framed kneewalls, skylight shafts, and gable ends are covered with insulation. 06 Verification Status Pass - all applicable requirements are met. 07 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. F. Ceiling Insulation in Vented Attics 01 Required eave ventilation shall not be obstructed. The net-free ventilation area of the eave vent is maintained. 02 Eave vent baffles and dams are installed to prevent air movement under or into the ceiling insulation. 03 Attic access is insulated to the same R-value required by the Certificate of Compliance for ceiling insulation and the insulation is permanently attached using adhesive or mechanical fasteners. 04 Attic access must have a dam around the access to at least the same depth as the insulation. 05 Attic rulers specified to the installed loose-fill material (brand and type) are installed and evenly distributed throughout the attic to verify depth (one ruler for every 250 ft2). The rulers are clearly readable and scaled to read inches of insulation and the R-value installed. 06 Verification Status Pass - all applicable requirements are met. 07 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Insulation in unvented Attics 01 The roof sheathing is the air barrier and is sealed to prevent air movement to the outside. 02 Insulation is in full contact with the air barrier (roof sheathing). 03 If insulated using air permeable insulation, gable end walls are sealed and insulated the same as exterior walls, including interior air barrier. 04 Verification Status Pass - all applicable requirements are met. 05 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H QII - Insulation Installation (Page 4 of 7) Registration Number: 422-P010021377A-000-001-E22020A-E22A Registration Date/Time: 2023-04-24   13:33:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:19 H. Insulation in Vented Attics (High Performance Vented Attics) 01 Insulation is in full contact with roof sheathing and firmly supported to prevent sagging. 02 Batt insulation between roof trusses is acceptable with minimal gaps and voids caused by roof truss members. 03 Insulation is not required on gable end walls. 04 Required roof deck insulation over any conditioned space, or HVAC ducts, is installed on the entire attic roof deck; even over unconditioned spaces (e.g., garage, covered porch). Roof deck of attic over unconditioned space without HVAC ducts and separated from other attics by a sealed air barrier do not need to be insulated. 05 Verification Status Pass - all applicable requirements are met. 06 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. I. Special Requirements for Skylight Shafts and Attic Knee Walls 01 Insulation must meet all the requirements for walls and insulation is in contact with the air barrier on all six sides unless SPF is used. 02 Insulation shall be in full contact with the interior wall finish. Batt insulation must be cut to fit around 2x4's that are laid flat. 03 Skylight shafts and attic knee walls shall be completely enclosed by vertical and horizontal framing, including horizontal plates at the top and bottom of the insulation. 04 Verification Status Pass - all applicable requirements are met. 05 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. J. Special Requirements for Floors Above Garages 01 If the air barrier is at the perimeter of the garage below the conditioned subfloor, then the insulation may be placed on the garage ceiling. The perimeter of the subfloor must also be insulated. 02 Verification Status Pass - all applicable requirements are met. 03 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H QII - Insulation Installation (Page 5 of 7) Registration Number: 422-P010021377A-000-001-E22020A-E22A Registration Date/Time: 2023-04-24   13:33:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:19 K. Special Requirements for Cantilevered Floors 01 Sealed blocking shall be installed between joists where the wall rim joist would have been located in the absence of a cantilever. Insulation shall be placed on both sides of the block. 02 Verification Status Pass - all applicable requirements are met. 03 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. L. Special Requirements for Attached Porches 01 Exterior wall at the intersection of the porch roof is fully insulated above, below and behind the roof line. 02 Where truss framing is used, airtight blocking is used at the top and bottom of each wall/ roof section and is insulated. 03 Verification Status Pass - all applicable requirements are met. 04 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. M. Special Requirements for SPF Insulation 01 Installed product meets the claimed R-value per inch. Non-standard values are supported by an ICC Evaluation Service Report (ESR) number (e.g., ESR-xxxx) and documented on the CF2R-ENV-03. Non-standard values are anything greater than R-5.8/inch for closed cell and R-3.6/inch for open cell. 02 Installed thickness meets the required R-value from the Certificate of Compliance. Verified in at least 6 random places for each surface type: floors, walls and ceilings. 03 Insulation is spray applied to fully adhere to structural assembly framing, floor and ceiling joists, and other framing surfaces within the construction cavity. 04 If multiple layers are applied, each foam lift (e.g., spray application) adheres to the substrate and foam interfaces. 05 Closed cell SPF: In area where an air barrier is required the foam is at least 2" thick. 06 Open cell SPF: In area where an air barrier is required the foam is at least 5.5" thick. 07 Open cell SPF: Depressions in the foam insulation are not greater than 1/2" of the required thickness provided these depressions do not exceed 10% of the surface area being insulated. 08 Open cell SPF: Insulation completely fills cavities of 2x4 framing. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H QII - Insulation Installation (Page 6 of 7) Registration Number: 422-P010021377A-000-001-E22020A-E22A Registration Date/Time: 2023-04-24   13:33:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:19 M. Special Requirements for SPF Insulation 09 SPF insulation is not applied directly to recessed lighting fixtures unless specifically allowed by manufacturer's instructions. when not allowed, can lights are: A.Covered with a minimum of 1.5" of mineral fiber insulation or B.Enclosed in a manufacturer's approved box fabricated from an approved material, such as 18 gauge sheet metal or 1/2" gypsum board. 10 Verification Status Pass - all applicable requirements are met. 11 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. N. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H QII - Insulation Installation (Page 7 of 7) Registration Number: 422-P010021377A-000-001-E22020A-E22A Registration Date/Time: 2023-04-24   13:33:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:19 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M27005A-M27A Registration Date/Time: 2023-04-24   13:32:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:32:23 CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2.-2016 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings subject to amendments specified by Title 24, Part 6 Section 150.0(o)1. A. Dwelling Mechanical Ventilation - General Information 01 Dwelling unit name Single Family Dwelling 02 Building Type Single family detached 03 Project scope Newly Constructed 04 Total Conditioned Floor Area of Dwelling Unit (For addition projects the conditioned floor area equals existing area plus addition area. ) 9391 05 Number of Bedrooms in Dwelling Unit (For addition projects the number of bedrooms equals the existing bedrooms plus addition bedrooms) 6 06 Ventilation System Type Exhaust 07 Ventilation Operation Schedule Continuous Note: Non-dwelling units do not meet the definition for a dwelling unit as defined in Section 100.1(b). Non-dwelling units are not designed to provide independent living facilities and do not provide permanent provisions for living, sleeping, eating, cooking and sanitation. MCH-27a - Single Family Attached/Detached B. Single Family Attached/Detached General Information 01 Average Ceiling Height 8 02 Total Conditioned Volume 75128 03 Vertical distance between the lowest and highest above grade points within the pressure boundary in feet 22 04 Air Changes Per Hour at 50 Pa Default 05 Name of ANSI/ASHRAE Standard 62.2-2016 weather station for climate zone Palm Springs Intl 06 Weather and shielding factor (wsf) (Based on city identified above)0.45 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M27005A-M27A Registration Date/Time: 2023-04-24   13:32:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:32:23 C. Ventilation - Total Ventilation Rate A mechanical supply system, exhaust system or combination thereof shall provide whole-building ventilation with outdoor air each hour at no less than the rate in 150.0(o)1Ci 01 Total Required Ventilation Rate (Qtot)334.23 02 Enclosure Leakage Rate (Q50)2504.27 03 Effective Annual Average Infiltration Rate (Qinf 86.96 04 Total Exterior Envelope Surface Area n/a 05 Unshared Exterior Envelope Surface Area (exclude surface areas attached to garages or other dwelling units) n/a 06 Required Mechanical Ventilation Rate (Qfan)311.6 D. Installed Ventilation - Total Ventilation Rate A mechanical supply system, exhaust system, or combination thereof shall provide whole-building ventilation with outdoor air each hour at no less than the rate in 150.0(o)1Ci 01 02 03 04 05 Fan Name Fan Location Runtime (min/hr)Installed Mechanical Ventilation Rate (CFM) Equivalent Continuous Ventilation (CFM) 60 400 400 06 Total Installed Continuous Ventilation (CFM)400 E. Compliance Statement 01 Building Passes Mechanical Ventilation RateTest F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M27005A-M27A Registration Date/Time: 2023-04-24   13:32:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200401 Report Generated: 2023-04-24   13:32:23 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M32036A-M32A Registration Date/Time: 2023-04-24   13:33:17 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 CERTIFICATE OF VERIFICATION CF3R-MCH-32-H Local Mechanical Exhaust (Page 1 of 2) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Equation and table numbering on this form corresponds to the numbering for that information in the published ANSI/ASHRAE Standard 62.2-2010 A. Local Mechanical Exhaust - General Information 01 Dwelling unit name Single Family Dwelling 02 Building Type Single family attached 03 Total Kitchen Floor Area 2000 04 Kitchen Average Ceiling Height 10 05 Kitchen Total Conditioned Volume 20000 06 Kitchen Type Non-Enclosed B. Kitchen Exhaust System 01 02 03 04 05 06 07 08 09 10 11 System Name Manufacturer Name System Type HVI or AHAM Directory Listed Model Number HVI or AHAM Directory Listed Rated Airflow HVI or AHAM Directory Listed Sound Rating Minimum Airflow (defaults to rated airflow) Operation Schedule Required Minimum Ventilation Rate (if demand controlled) Maximum Sound Rating Compliance Statement 1 ALTRA Vented Range Hood 56544 654648 .9 200 Demand Control 100 3 sone Complies C. Continuous Kitchen Exhaust 01 Total Continuous Ventilation Airflow n/a 02 Required Minimum Continuous Ventilation Airflow n/a 03 Compliance Statement n/a D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-32-H Local Mechanical Exhaust (Page 2 of 2) Registration Number: 422-P010021377A-000-001-M32036A-M32A Registration Date/Time: 2023-04-24   13:33:17 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed:   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20030A-M20A Registration Date/Time: 2023-04-24   13:32:25 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:25 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Location or Area Served Master 03 Indoor Unit Name or Description of Area Served Master 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1391 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.03 10 Calculated Target Allowable Duct Leakage (cfm)36 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm) 36 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20030A-M20A Registration Date/Time: 2023-04-24   13:32:25 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:25 B. Duct Leakage Diagnostic Test 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test 15 Notes:  C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. 08 Verification Status:Pass - all applicable requirements are met. 09 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20030A-M20A Registration Date/Time: 2023-04-24   13:32:25 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23035A-M23A Registration Date/Time: 2023-04-24   13:32:28 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Description of Area Served Master 03 Indoor Unit Name Master 04 System Installation Type New 05 Nominal Cooling Capacity (tons)3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23035A-M23A Registration Date/Time: 2023-04-24   13:32:28 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1050 03 Actual System Airflow Rate Measurement (cfm)1804 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Verification. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 09 Verification Status:Pass - all applicable requirements are met. 10 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23035A-M23A Registration Date/Time: 2023-04-24   13:32:28 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22052A-M22A Registration Date/Time: 2023-04-24   13:54:43 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:28 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 11 02 System Location or Area Served Master 03 Indoor Unit Name or Description of Area Served Master 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 214 02 Actual Tested Airflow from MCH-23 (cfm)1804 03 Required Fan Efficacy (Watts/cfm)0.31 04 Actual Fan Efficacy (watts/cfm)0.12 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22052A-M22A Registration Date/Time: 2023-04-24   13:54:43 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:28 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater 08 Verification Status Pass - all applicable requirements are met. 09 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22052A-M22A Registration Date/Time: 2023-04-24   13:54:43 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:28 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25029A-M25A Registration Date/Time: 2023-04-24   13:52:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:02:25 CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information HERS Rater to field-verify all system information, discrepancies to be noted by overwriting entry. 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Location or Area Served Master 03 Condenser (or package unit) make or brand 04 Condenser (or package unit) model number 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) serial number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer) This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling 18 Refrigerant charge verification method used by HERS Rater.Subcooling MCH-25b - Refrigerant Charge Verification - Subcooling Method NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M25029A-M25A Registration Date/Time: 2023-04-24   13:52:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:02:25 B. Metering Device Verification HERS Rater is required to visually field verify all information from CF2R. Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration HERS Raters are required to calibrate their diagnostic tools. Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2023-04-04 02 Date of Digital Thermocouple Calibration 2023-04-04 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification HERS Raters are required to visually field verify MAH. Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Master 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M25029A-M25A Registration Date/Time: 2023-04-24   13:52:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:02:25 F. Data Collection and Calculations HERS Rater must independently collect all data in this section. Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure ( °F) 70 02 Measured Condenser Air Entering Dry-Bulb Temperature (Tcondenser, db) 75 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method 04 Measured Liquid Line Temperature (Tliquid) ( °F)102.3 05 Measured Liquid Line Pressure (Pliquid) (psig)256.3 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 ( °F) 111.2 07 Measured Subcooling (Line F06 - Lilne F04 ( °F)8.9 08 Target Subcooling from Manufacturer ( °F)8 09 Compliance Statement:System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification HERS Rater must independently collect all data in this section. Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) ( °F)60.3 02 Measured Suction Line Pressure (Psuction) (psig)105.4 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 ( °F) 51.2 04 Measured Superheat (Line G01- Line G03) ( °F)9.1 05 Measured Superheat (Line G04) is between 3 °F and 26 °F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement:Metering device verification passes H. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M25029A-M25A Registration Date/Time: 2023-04-24   13:52:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   14:02:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed:   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26049A-M26A Registration Date/Time: 2023-04-24   13:56:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 11 02 Space Conditioning System Description of Area Served Master 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 16546464 09 Does the directory used to certify product performance require a specific air handler/furnace make and model? No 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from Nameplate of Installed System Component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 11 Master Master HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26049A-M26A Registration Date/Time: 2023-04-24   13:56:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name on CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 11 Master Master HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 59000 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating BTU Output at 17 Degrees F 49500 04 Installed Heating BTU Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF2R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26049A-M26A Registration Date/Time: 2023-04-24   13:56:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 G. Verified Heat Pump HSPF 01 Required minimum HSPF 11 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil This section does not apply to this project. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. 02 Verification Status:Pass - all applicable requirements are met. 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. J. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26049A-M26A Registration Date/Time: 2023-04-24   13:56:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20009A-M20A Registration Date/Time: 2023-04-24   13:32:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:36 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Location or Area Served Bedrooms 03 Indoor Unit Name or Description of Area Served Bedrooms 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1000 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)60 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm) 0.1 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20009A-M20A Registration Date/Time: 2023-04-24   13:32:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:36 B. Duct Leakage Diagnostic Test 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test 15 Notes:  C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. 08 Verification Status:Pass - all applicable requirements are met. 09 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20009A-M20A Registration Date/Time: 2023-04-24   13:32:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:36 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23011A-M23A Registration Date/Time: 2023-04-24   13:32:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:32:39 CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Description of Area Served Bedrooms 03 Indoor Unit Name Bedrooms 04 System Installation Type New 05 Nominal Cooling Capacity (tons)2 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23011A-M23A Registration Date/Time: 2023-04-24   13:32:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:32:39 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)700 03 Actual System Airflow Rate Measurement (cfm)1074 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Verification. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 09 Verification Status:Pass - all applicable requirements are met. 10 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23011A-M23A Registration Date/Time: 2023-04-24   13:32:39 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:32:39 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22013A-M22A Registration Date/Time: 2023-04-24   13:32:44 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:44 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 22 02 System Location or Area Served Bedrooms 03 Indoor Unit Name or Description of Area Served Bedrooms 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 2 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 100 02 Actual Tested Airflow from MCH-23 (cfm)1074 03 Required Fan Efficacy (Watts/cfm)0.31 04 Actual Fan Efficacy (watts/cfm)0.09 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22013A-M22A Registration Date/Time: 2023-04-24   13:32:44 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:44 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater 08 Verification Status Pass - all applicable requirements are met. 09 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22013A-M22A Registration Date/Time: 2023-04-24   13:32:44 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:44 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25027A-M25A Registration Date/Time: 2023-04-24   13:33:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:05 CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information HERS Rater to field-verify all system information, discrepancies to be noted by overwriting entry. 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Location or Area Served Bedrooms 03 Condenser (or package unit) make or brand 04 Condenser (or package unit) model number 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) serial number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer) This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling 18 Refrigerant charge verification method used by HERS Rater.Subcooling MCH-25b - Refrigerant Charge Verification - Subcooling Method NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M25027A-M25A Registration Date/Time: 2023-04-24   13:33:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:05 B. Metering Device Verification HERS Rater is required to visually field verify all information from CF2R. Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration HERS Raters are required to calibrate their diagnostic tools. Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2023-04-04 02 Date of Digital Thermocouple Calibration 2023-04-04 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification HERS Raters are required to visually field verify MAH. Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Bedrooms 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M25027A-M25A Registration Date/Time: 2023-04-24   13:33:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:05 F. Data Collection and Calculations HERS Rater must independently collect all data in this section. Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure ( °F) 77 02 Measured Condenser Air Entering Dry-Bulb Temperature (Tcondenser, db) 95 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method 04 Measured Liquid Line Temperature (Tliquid) ( °F)103.4 05 Measured Liquid Line Pressure (Pliquid) (psig)241.2 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 ( °F) 112.4 07 Measured Subcooling (Line F06 - Lilne F04 ( °F)9 08 Target Subcooling from Manufacturer ( °F)8 09 Compliance Statement:System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification HERS Rater must independently collect all data in this section. Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) ( °F)60.4 02 Measured Suction Line Pressure (Psuction) (psig)108.6 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 ( °F) 50.4 04 Measured Superheat (Line G01- Line G03) ( °F)10 05 Measured Superheat (Line G04) is between 3 °F and 26 °F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement:Metering device verification passes H. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M25027A-M25A Registration Date/Time: 2023-04-24   13:33:06 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:05 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26032A-M26A Registration Date/Time: 2023-04-24   13:33:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:08 CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 22 02 Space Conditioning System Description of Area Served Bedrooms 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 1254879 09 Does the directory used to certify product performance require a specific air handler/furnace make and model? Non-furnace air-handling unit 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from Nameplate of Installed System Component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 22 Bedrooms Bedrooms HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26032A-M26A Registration Date/Time: 2023-04-24   13:33:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:08 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name on CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 22 Bedrooms Bedrooms HP Coil CARRIER 25VA436A00 3 CARRIER 25VA436A00 3 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 59000 02 Installed Heating BTU Output at 47 Degrees F 59000 03 Required Heating BTU Output at 17 Degrees F 49500 04 Installed Heating BTU Output at 17 Degrees F 49500 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF2R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26032A-M26A Registration Date/Time: 2023-04-24   13:33:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:08 G. Verified Heat Pump HSPF 01 Required minimum HSPF 11 02 Installed HSPF 11 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil 01 If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of Certified Product Performance. 02 Verification Status:Pass - all applicable requirements are met. 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. 02 Verification Status:Pass - all applicable requirements are met. 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. J. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26032A-M26A Registration Date/Time: 2023-04-24   13:33:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:08 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20003A-M20A Registration Date/Time: 2023-04-24   13:32:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:09 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Location or Area Served Kids room 03 Indoor Unit Name or Description of Area Served Kids room 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)60 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm) 40 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20003A-M20A Registration Date/Time: 2023-04-24   13:32:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:09 B. Duct Leakage Diagnostic Test 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test 15 Notes:  C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. 08 Verification Status:Pass - all applicable requirements are met. 09 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20003A-M20A Registration Date/Time: 2023-04-24   13:32:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:09 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23006A-M23A Registration Date/Time: 2023-04-24   13:32:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:32:12 CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Description of Area Served Kids room 03 Indoor Unit Name Kids room 04 System Installation Type New 05 Nominal Cooling Capacity (tons)3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23006A-M23A Registration Date/Time: 2023-04-24   13:32:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:32:12 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1050 03 Actual System Airflow Rate Measurement (cfm)1089 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Verification. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 09 Verification Status:Pass - all applicable requirements are met. 10 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23006A-M23A Registration Date/Time: 2023-04-24   13:32:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:32:12 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22008A-M22A Registration Date/Time: 2023-04-24   13:32:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:19 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 33 02 System Location or Area Served Kids room 03 Indoor Unit Name or Description of Area Served Kids room 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 100 02 Actual Tested Airflow from MCH-23 (cfm)1089 03 Required Fan Efficacy (Watts/cfm)0.22 04 Actual Fan Efficacy (watts/cfm)0.09 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22008A-M22A Registration Date/Time: 2023-04-24   13:32:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:19 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater 08 Verification Status Pass - all applicable requirements are met. 09 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22008A-M22A Registration Date/Time: 2023-04-24   13:32:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:19 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M25031A-M25A Registration Date/Time: 2023-04-24   13:33:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:12 CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information HERS Rater to field-verify all system information, discrepancies to be noted by overwriting entry. 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Location or Area Served Kids room 03 Condenser (or package unit) make or brand 04 Condenser (or package unit) model number 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) serial number 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable)n/a 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer) This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified for all indoor units using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55 °F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2023-04-24 15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling 18 Refrigerant charge verification method used by HERS Rater.Subcooling MCH-25b - Refrigerant Charge Verification - Subcooling Method NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M25031A-M25A Registration Date/Time: 2023-04-24   13:33:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:12 B. Metering Device Verification HERS Rater is required to visually field verify all information from CF2R. Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration HERS Raters are required to calibrate their diagnostic tools. Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2023-04-04 02 Date of Digital Thermocouple Calibration 2023-04-04 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification HERS Raters are required to visually field verify MAH. Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 02 03 Indoor Unit Name or Description of Area Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status Kids room 1050 System complies with minimum airflow rate requirements 04 SC System complies with Minimum System Airflow Rate Verification Notes: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M25031A-M25A Registration Date/Time: 2023-04-24   13:33:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:12 F. Data Collection and Calculations HERS Rater must independently collect all data in this section. Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure ( °F) 70 02 Measured Condenser Air Entering Dry-Bulb Temperature (Tcondenser, db) 76 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method 04 Measured Liquid Line Temperature (Tliquid) ( °F)102.6 05 Measured Liquid Line Pressure (Pliquid) (psig)256.3 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 ( °F) 110.5 07 Measured Subcooling (Line F06 - Lilne F04 ( °F)7.9 08 Target Subcooling from Manufacturer ( °F)8 09 Compliance Statement:System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification HERS Rater must independently collect all data in this section. Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) ( °F)60.3 02 Measured Suction Line Pressure (Psuction) (psig)102.3 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 ( °F) 52 04 Measured Superheat (Line G01- Line G03) ( °F)8.3 05 Measured Superheat (Line G04) is between 3 °F and 26 °F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement:Metering device verification passes H. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M25031A-M25A Registration Date/Time: 2023-04-24   13:33:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20200901 Report Generated: 2023-04-24   13:33:12 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26033A-M26A Registration Date/Time: 2023-04-24   13:33:14 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:14 CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 33 02 Space Conditioning System Description of Area Served Kids room 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 16546464 09 Does the directory used to certify product performance require a specific air handler/furnace make and model? Non-furnace air-handling unit 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from Nameplate of Installed System Component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 33 Kids room Kids room HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26033A-M26A Registration Date/Time: 2023-04-24   13:33:14 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:14 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name on CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 33 Kids room Kids room HP Coil carrier 25VANA436A 00 CARRIER 25VANA436A 00 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 34600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating BTU Output at 17 Degrees F 32600 04 Installed Heating BTU Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF2R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26033A-M26A Registration Date/Time: 2023-04-24   13:33:14 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:14 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10.5 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil 01 If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of Certified Product Performance. 02 Verification Status:Pass - all applicable requirements are met. 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. 02 Verification Status:Pass - all applicable requirements are met. 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. J. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26033A-M26A Registration Date/Time: 2023-04-24   13:33:14 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   13:33:14 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20002A-M20A Registration Date/Time: 2023-04-24   13:32:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:47 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 44 02 Space Conditioning System Location or Area Served Kitchen 03 Indoor Unit Name or Description of Area Served Kitchen 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?No, credit is not taken 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20a - Completely New Duct System NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M20002A-M20A Registration Date/Time: 2023-04-24   13:32:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:47 B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)3 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)60 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)41 12 Compliance Statement System passes leakage test 13 Notes: C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. 02 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 03 All supply and return register boots were sealed to the drywall. 04 Building cavities were not used as plenums or platform returns in lieu of ducts. 05 If cloth backed tape was used it was covered with Mastic and draw bands. 06 All connection points between the air handler and the supply and return plenums are completely sealed. Visual Inspection at Final Construction Stage (applicable if system was tested at rough-in). After installing the interior finishing wall and verifying that the above rough-in tests was completed, the following procedure must be performed 07 For all supply and return registers, verify that the spaces between the register boot and the interior finishing wall are properly sealed. 08 If the house rough-in duct leakage test was conducted without an air handler installed, inspect the connection points between the air handler and the supply and return plenums to verify that the connection points are properly sealed. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M20002A-M20A Registration Date/Time: 2023-04-24   13:32:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:47 09 Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used. 10 Verification Status:Pass - all applicable requirements are met. 11 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M20002A-M20A Registration Date/Time: 2023-04-24   13:32:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:47 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23048A-M23A Registration Date/Time: 2023-04-24   13:51:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 44 02 Space Conditioning System Description of Area Served Kitchen 03 Indoor Unit Name Kitchen 04 System Installation Type New 05 Nominal Cooling Capacity (tons)5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23048A-M23A Registration Date/Time: 2023-04-24   13:51:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1750 03 Actual System Airflow Rate Measurement (cfm)1845 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Verification. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 09 Verification Status:Pass - all applicable requirements are met. 10 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23048A-M23A Registration Date/Time: 2023-04-24   13:51:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22050A-M22A Registration Date/Time: 2023-04-24   13:51:13 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 44 02 System Location or Area Served Kitchen 03 Indoor Unit Name or Description of Area Served Kitchen 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 321 02 Actual Tested Airflow from MCH-23 (cfm)1845 03 Required Fan Efficacy (Watts/cfm)0.18 04 Actual Fan Efficacy (watts/cfm)0.17 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22050A-M22A Registration Date/Time: 2023-04-24   13:51:13 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater 08 Verification Status Pass - all applicable requirements are met. 09 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22050A-M22A Registration Date/Time: 2023-04-24   13:51:13 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26056A-M26A Registration Date/Time: 2023-04-24   14:00:17 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:00:17 CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 44 02 Space Conditioning System Description of Area Served Kitchen 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 16564654 09 Does the directory used to certify product performance require a specific air handler/furnace make and model? No 10 Does the directory used to certify product performance require a time delay relay (+TDR)? No 11 Does the directory used to certify product performance require a TXV (+TXV)? No B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from Nameplate of Installed System Component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 44 Kitchen Kitchen HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26056A-M26A Registration Date/Time: 2023-04-24   14:00:17 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:00:17 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name on CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 44 Kitchen Kitchen HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 18.6 02 Installed SEER 18.6 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 27600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating BTU Output at 17 Degrees F 26200 04 Installed Heating BTU Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF2R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26056A-M26A Registration Date/Time: 2023-04-24   14:00:17 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:00:17 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil This section does not apply to this project. I. Verified Space Conditioning System Time Delay Relay This section does not apply to this project. J. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26056A-M26A Registration Date/Time: 2023-04-24   14:00:17 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:00:17 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20012A-M20A Registration Date/Time: 2023-04-24   13:32:50 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:50 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 55 02 Space Conditioning System Location or Area Served Living Room 03 Indoor Unit Name or Description of Area Served Living Room 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)4.99 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)99.8 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm) 33 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20012A-M20A Registration Date/Time: 2023-04-24   13:32:50 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:50 B. Duct Leakage Diagnostic Test 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test 15 Notes:  C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. 08 Verification Status:Pass - all applicable requirements are met. 09 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20012A-M20A Registration Date/Time: 2023-04-24   13:32:50 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:50 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23016A-M23A Registration Date/Time: 2023-04-24   13:56:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:28 CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 55 02 Space Conditioning System Description of Area Served Living Room 03 Indoor Unit Name Living Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons)5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23016A-M23A Registration Date/Time: 2023-04-24   13:56:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:28 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1750 03 Actual System Airflow Rate Measurement (cfm)1802 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Verification. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 09 Verification Status:Pass - all applicable requirements are met. 10 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23016A-M23A Registration Date/Time: 2023-04-24   13:56:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:28 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22054A-M22A Registration Date/Time: 2023-04-24   13:56:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:28 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 55 02 System Location or Area Served Living Room 03 Indoor Unit Name or Description of Area Served Living Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 233 02 Actual Tested Airflow from MCH-23 (cfm)1802 03 Required Fan Efficacy (Watts/cfm)0.24 04 Actual Fan Efficacy (watts/cfm)0.13 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22054A-M22A Registration Date/Time: 2023-04-24   13:56:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:28 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater 08 Verification Status Pass - all applicable requirements are met. 09 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22054A-M22A Registration Date/Time: 2023-04-24   13:56:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:28 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26044A-M26A Registration Date/Time: 2023-04-24   14:01:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:03:52 CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 55 02 Space Conditioning System Description of Area Served Living Room 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 31655646465 09 Does the directory used to certify product performance require a specific air handler/furnace make and model? No 10 Does the directory used to certify product performance require a time delay relay (+TDR)? No 11 Does the directory used to certify product performance require a TXV (+TXV)? No B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from Nameplate of Installed System Component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 55 Living Room Living Room HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26044A-M26A Registration Date/Time: 2023-04-24   14:01:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:03:52 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name on CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 55 Living Room Living Room HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 34600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating BTU Output at 17 Degrees F 32600 04 Installed Heating BTU Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF2R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26044A-M26A Registration Date/Time: 2023-04-24   14:01:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:03:52 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10.5 02 Installed HSPF 12 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil This section does not apply to this project. I. Verified Space Conditioning System Time Delay Relay This section does not apply to this project. J. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26044A-M26A Registration Date/Time: 2023-04-24   14:01:20 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:03:52 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M20014A-M20A Registration Date/Time: 2023-04-24   13:32:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:52 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information 01 Space Conditioning System Identification or Name HVAC System 66 02 Space Conditioning System Location or Area Served Great Room 03 Indoor Unit Name or Description of Area Served Great Room 04 Building Type from CF-1R Single family 05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 06 Verified Low Leakage Air Handling Unit Credit from CF1R?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be used 07 Duct System Compliance Category New 08 Portions of Duct Located in Garage?No 09 Is the system type Small Duct High Velocity (SDHV) ?No MCH-20c - Low Leakage Air-Handling Unit (LLAHU) B. Duct Leakage Diagnostic Test 01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method 02 Condenser Nominal Cooling Capacity (ton)5 03 Indoor Unit Nominal Cooling Capacity n/a 04 Heating Capacity (kBtu/h)n/a 05 Conditioned Floor Area Served by this HVAC System (ft2)1750 06 Measured AHU Airflow (cfm)n/a 07 Duct Leakage Test Conditions Test final 08 Duct Leakage Test Method Total leakage 09 Leakage Factor 0.05 10 Calculated Target Allowable Duct Leakage (cfm)100 11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm) 60 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M20014A-M20A Registration Date/Time: 2023-04-24   13:32:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:52 B. Duct Leakage Diagnostic Test 12 Air Handling Unit Manufacturer Name 13 Air Handling Unit Model Number 14 Compliance Statement System passes leakage test 15 Notes:  C. Additional Requirements for Compliance 01 The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air-Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. 08 Verification Status:Pass - all applicable requirements are met. 09 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M20014A-M20A Registration Date/Time: 2023-04-24   13:32:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   13:32:52 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Breeze Air Conditioning LLC Responsible Builder or Installer Name: Butch White CSLB License: 1045015 HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2023-04-24   NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M23045A-M23A Registration Date/Time: 2023-04-24   13:54:18 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:01:01 CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 Space Conditioning System Identification or Name HVAC System 66 02 Space Conditioning System Description of Area Served Great Room 03 Indoor Unit Name Great Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons)5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus ALNOR 03 Model number of Airflow Measurement Apparatus EBT731 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index. html MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M23045A-M23A Registration Date/Time: 2023-04-24   13:54:18 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:01:01 D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton)350 02 Required Minimum System Airflow Target (cfm)1750 03 Actual System Airflow Rate Measurement (cfm)1825 04 Compliance Statement:System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Verification. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 09 Verification Status:Pass - all applicable requirements are met. 10 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M23045A-M23A Registration Date/Time: 2023-04-24   13:54:18 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:01:01 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M22046A-M22A Registration Date/Time: 2023-04-24   13:54:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. Ducted Cooling System Information 01 System Identification or Name HVAC System 66 02 System Location or Area Served Great Room 03 Indoor Unit Name or Description of Area Served Great Room 04 System Installation Type New 05 Nominal Cooling Capacity (tons) of Condenser 5 06 Condenser Speed Type Multi-speed 07 Cooling System Zonal Control Type Not Zonal 08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 09 System Bypass Duct Status No Bypass Duct 10 Date of System Airflow Rate Measurement 2023-04-24 11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement 12 Central Fan Ventilation Cooling System Status Not a CFVCS B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used.Portable Watt Meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 265 02 Actual Tested Airflow from MCH-23 (cfm)1825 03 Required Fan Efficacy (Watts/cfm)0.28 04 Actual Fan Efficacy (watts/cfm)0.15 05 Compliance Statement:System fan efficacy complies NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) Registration Number: 422-P010021377A-000-001-M22046A-M22A Registration Date/Time: 2023-04-24   13:54:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater 08 Verification Status Pass - all applicable requirements are met. 09 Correction Notes The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Registration Number: 422-P010021377A-000-001-M22046A-M22A Registration Date/Time: 2023-04-24   13:54:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20210501 Report Generated: 2023-04-24   14:02:25 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010021377A-000-001-M26057A-M26A Registration Date/Time: 2023-04-24   13:58:30 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:28 CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Lot 66 Madison Club Enforcement Agency: Palm Desert, City of Permit Number: 2021 Dwelling Address: 81-370 Peary Place City: La Quinta Zip Code: 92260 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 Space Conditioning System Identification or Name HVAC System 66 02 Space Conditioning System Description of Area Served Great Room 03 Status: SEER Performance Compliance Credit Check Yes 04 Status: EER Performance Compliance Credit Check No 05 Status: Heat Pump Heating Output Performance Compliance Check Yes 06 Status: HSPF Performance Compliance Credit Check Yes 07 Directory used to certify product performance AHRI 08 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 231654654 09 Does the directory used to certify product performance require a specific air handler/furnace make and model? Non-furnace air-handling unit 10 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 11 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from Nameplate of Installed System Component 05 06 07 08 09 10 SC System ID/Name from CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 66 Great Room Great Room HP Coil Carrier FN1AAF0150 0 n/a n/a NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) Registration Number: 422-P010021377A-000-001-M26057A-M26A Registration Date/Time: 2023-04-24   13:58:30 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:28 C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. 01 02 03 04 Data from the Directory used to certify product performance for the rated system component 05 06 07 08 09 10 SC System ID/Name on CF1R SC System Description of Area Served Indoor Unit Name or Description of Area Served Installed Indoor Unit Type Outdoor Condenser or Package Unit - Installed Manufacture r Name Outdoor Condenser or Package Unit - Installed Model Number Indoor Unit - Installed Manufacture r Name Indoor Unit - Installed Model Number Installed Furnace Manufacture r Name Installed Furnace Model Number HVAC System 66 Great Room Great Room HP Coil CARRIER 25VNA460A0 03 CARRIER 25VNA460A0 03 n/a n/a D. Verified Cooling System SEER 01 Required minimum SEER 21 02 Installed SEER 21 03 Compliance Statement:System passes SEER verification Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. E. Verified Cooling System EER This section does not apply to this project. F. Verified Heat Pump Heating Output 01 Required Heating BTU Output at 47 Degrees F 34600 02 Installed Heating BTU Output at 47 Degrees F 60000 03 Required Heating BTU Output at 17 Degrees F 32600 04 Installed Heating BTU Output at 17 Degrees F 60000 05 Compliance Statement:System Passes Heat Pump Heating Output Performance Compliance Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF2R. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) Registration Number: 422-P010021377A-000-001-M26057A-M26A Registration Date/Time: 2023-04-24   13:58:30 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:28 G. Verified Heat Pump HSPF 01 Required minimum HSPF 10.5 02 Installed HSPF 16 03 Compliance Statement:System Passes HSPF Verification Signature by responsible person on this compliance document certifies that the installed heat pump equipment meets or exceeds the required value listed on the CF1R. H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil 01 If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of Certified Product Performance. 02 Verification Status:Pass - all applicable requirements are met. 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. I. Verified Space Conditioning System Time Delay Relay 01 If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. 02 Verification Status:Pass - all applicable requirements are met. 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. J. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Registration Number: 422-P010021377A-000-001-M26057A-M26A Registration Date/Time: 2023-04-24   13:58:30 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2019 Residential Compliance Report Version: 2019.1.006 Schema Version: rev 20191201 Report Generated: 2023-04-24   14:02:28 Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Company: MLC Building Performance Date Signed: 2023-04-24 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Verification is true and correct. 2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name:CSLB License: HERS Provider Data Registry Information Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable) HERS Rater Information HERS Rater Company Name: Responsible Rater Name:Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider:Date Signed: NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Scan to Validate CHEERS REGISTRY PROJECT STATUS REPORT CERTIFICATE OF COMPLIANCE (CF1R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS 02/15/2022 CF1R-PRF-01-E Performance Compliance 422-P010021377A-000-000-0000000-0000 CERTIFICATE OF INSTALLATION (CF2R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS 04/24/2023 CF2R-ENV-01-E Fenestration 422-P010021377A-000-001-E01058A-0000 04/24/2023 CF2R-ENV-03-E Insulation Installation 422-P010021377A-000-001-E03059A-0000 04/24/2023 CF2R-ENV-04-E Roofing Radiant Barrier 422-P010021377A-000-001-E04060A-0000 04/24/2023 CF2R-ENV-21-H QII 422-P010021377A-000-001-E21021A-0000 04/24/2023 CF2R-ENV-22-H QII 422-P010021377A-000-001-E22020A-0000 04/24/2023 CF2R-LTG-01-E Lighting 422-P010021377A-000-001-L01025A-0000 04/24/2023 CF2R-MCH-01a-E HVAC, Ducts and Fans 422-P010021377A-000-001-M01001A-0000 J04 changed from "Outdoors" to "UnconditionedAttic" J06 changed from "Outdoors" to "UnconditionedAttic" J04 changed from "Outdoors" to "UnconditionedAttic" J06 changed from "Outdoors" to "UnconditionedAttic" J04 changed from "Outdoors" to "UnconditionedAttic" J06 changed from "Outdoors" to "UnconditionedAttic" 04/24/2023 CF2R-MCH-27a-H Mechanical Ventilation 422-P010021377A-000-001-M27005A-0000 04/24/2023 CF2R-MCH-32-H Local Mechanical Exhaust 422-P010021377A-000-001-M32036A-0000 04/24/2023 CF2R-PLB-02a-E Single Family Hot Water 422-P010021377A-000-001-B02004A-0000 PROJECT SUMMARY Project Name:Lot 66 Madison Club Address:81-370 Peary Place City, State, Zip:La Quinta, CA 92260 Building Department:Palm Desert, City of Permit Number:2021 Building Energy Code:2019 Standards ENERGY CODE COMPLIANCE COMPLETE HERS VERIFIABLE MEASURES COMPLETE NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. Page 1 of 6 - continued on next page - Scan to Validate CHEERS REGISTRY PROJECT STATUS REPORT CERTIFICATE OF INSTALLATION (CF2R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS 04/24/2023 CF2R-PVB-01-E Photovoltaic Systems 422-P010021377A-000-001-P01063A-0000 04/24/2023 CF2R-SRA-01-E Solar New Construction 422-P010021377A-000-001-R01065A-0000 Bedrooms 04/24/2023 CF2R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20009A-0000 04/24/2023 CF2R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22013A-0000 04/24/2023 CF2R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23011A-0000 Great Room 04/24/2023 CF2R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20014A-0000 04/24/2023 CF2R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22046A-0000 04/24/2023 CF2R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23045A-0000 HVAC System 11 04/24/2023 CF2R-MCH-25b-H Refrigerant Charge 422-P010021377A-000-001-M25029A-0000 04/24/2023 CF2R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26049A-0000 HVAC System 22 04/24/2023 CF2R-MCH-25b-H Refrigerant Charge 422-P010021377A-000-001-M25027A-0000 04/24/2023 CF2R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26032A-0000 HVAC System 33 04/24/2023 CF2R-MCH-25b-H Refrigerant Charge 422-P010021377A-000-001-M25031A-0000 04/24/2023 CF2R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26033A-0000 HVAC System 44 04/24/2023 CF2R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26056A-0000 NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. Page 2 of 6 - continued on next page - Scan to Validate CHEERS REGISTRY PROJECT STATUS REPORT CERTIFICATE OF INSTALLATION (CF2R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS HVAC System 55 04/24/2023 CF2R-MCH-25f-E Refrigerant Charge 422-P010021377A-000-001-M25061A-0000 04/24/2023 CF2R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26044A-0000 HVAC System 66 04/24/2023 CF2R-MCH-25f-E Refrigerant Charge 422-P010021377A-000-001-M25062A-0000 04/24/2023 CF2R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26057A-0000 Kids room 04/24/2023 CF2R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20003A-0000 04/24/2023 CF2R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22008A-0000 04/24/2023 CF2R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23006A-0000 Kitchen 04/24/2023 CF2R-MCH-20a-H Duct Leakage 422-P010021377A-000-001-M20002A-0000 04/24/2023 CF2R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22050A-0000 04/24/2023 CF2R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23048A-0000 Living Room 04/24/2023 CF2R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20012A-0000 04/24/2023 CF2R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22054A-0000 04/24/2023 CF2R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23016A-0000 Master 04/24/2023 CF2R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20030A-0000 04/24/2023 CF2R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22052A-0000 NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. Page 3 of 6 - continued on next page - Scan to Validate CHEERS REGISTRY PROJECT STATUS REPORT CERTIFICATE OF INSTALLATION (CF2R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS 04/24/2023 CF2R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23035A-0000 CERTIFICATE OF VERIFICATION (CF3R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS 04/24/2023 CF3R-ENV-21-H QII 422-P010021377A-000-001-E21021A- E21A 04/24/2023 CF3R-ENV-22-H QII 422-P010021377A-000-001-E22020A- E22A 04/24/2023 CF3R-MCH-27a-H Mechanical Ventilation 422-P010021377A-000-001-M27005A- M27A 04/24/2023 CF3R-MCH-32-H Local Mechanical Exhaust 422-P010021377A-000-001-M32036A- M32A Bedrooms 04/24/2023 CF3R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20009A- M20A 04/24/2023 CF3R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22013A- M22A 04/24/2023 CF3R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23011A- M23A Great Room 04/24/2023 CF3R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20014A- M20A 04/24/2023 CF3R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22046A- M22A 04/24/2023 CF3R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23045A- M23A HVAC System 11 04/24/2023 CF3R-MCH-25b-H Refrigerant Charge 422-P010021377A-000-001-M25029A- M25A 04/24/2023 CF3R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26049A- M26A HVAC System 22 04/24/2023 CF3R-MCH-25b-H Refrigerant Charge 422-P010021377A-000-001-M25027A- M25A 04/24/2023 CF3R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26032A- M26A NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. Page 4 of 6 - continued on next page - Scan to Validate CHEERS REGISTRY PROJECT STATUS REPORT CERTIFICATE OF VERIFICATION (CF3R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS HVAC System 33 04/24/2023 CF3R-MCH-25b-H Refrigerant Charge 422-P010021377A-000-001-M25031A- M25A 04/24/2023 CF3R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26033A- M26A HVAC System 44 04/24/2023 CF3R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26056A- M26A HVAC System 55 04/24/2023 CF3R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26044A- M26A HVAC System 66 04/24/2023 CF3R-MCH-26-H High SEER & EER 422-P010021377A-000-001-M26057A- M26A Kids room 04/24/2023 CF3R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20003A- M20A 04/24/2023 CF3R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22008A- M22A 04/24/2023 CF3R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23006A- M23A Kitchen 04/24/2023 CF3R-MCH-20a-H Duct Leakage 422-P010021377A-000-001-M20002A- M20A 04/24/2023 CF3R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22050A- M22A 04/24/2023 CF3R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23048A- M23A Living Room 04/24/2023 CF3R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20012A- M20A 04/24/2023 CF3R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22054A- M22A 04/24/2023 CF3R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23016A- M23A NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. Page 5 of 6 - continued on next page - Scan to Validate CHEERS REGISTRY PROJECT STATUS REPORT CERTIFICATE OF VERIFICATION (CF3R) DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS Master 04/24/2023 CF3R-MCH-20c-H Duct Leakage 422-P010021377A-000-001-M20030A- M20A 04/24/2023 CF3R-MCH-22a-H Fan Efficacy 422-P010021377A-000-001-M22052A- M22A 04/24/2023 CF3R-MCH-23a-H Airflow Rate 422-P010021377A-000-001-M23035A- M23A NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. Page 6 of 6