Loading...
BRES2021-0782DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Building Residential BRES2021-0782 80561 VIA SAVONA 777120005 $30,000.00 Declaration / Acknowledgement BUILDING PERMIT Ottigta CALIFORNIA PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 11/04/2021 ISSUED DATE: 03/01/2022 Owner: Jason Spire 80561 Via Savona, La Quinta, CA 92253 Applicant: Tyler Gallaudet 54065 AVENIDA DIAZ, LA QUINTA, CA 92253 Contractor: Tyler Gallaudet 54065 AVENIDA DIAZ, LA QUINTA, CA 92253 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.Ieg info.ca.gov/calaw. html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 10/24/23 11:04 pm Page 1 of 3 BUILDING PERMIT Permit Type: Building Residential Permit Number: BRES2021-0782 Property Address: 80561 VIA SAVONA Use of Permit SPIRE / REPLACE (10) WINDOWS AND FIREPLACE *** REPLACE (10) WINDOWS ALONG EAST SIDE OF DWELLING, RAISE AND LOWER VARIOUS WINDOW HEIGHTS + REMOVE EXISTING FIREPLACE AND REPLACE WITH NEW FACTORY -BUILT MASONRY UNIT MASON-LITE [CONVENTIONAL LIGHT -FRAME CONSTRUCTION]. THIS PERMIT DOES NOT INCLUDE ELECTRICAL OR ALTERATIONS 1 OTHER AREAS OF THE DWELLING. 2019 CALIFORNIA BUILDING CODES. Construction Details Residential Work Type Remodel Code Edition Number of Door/Window Retrofit/Repair New Electrical Square Footage 2019 10 0 Conditioned Square 0 Footage Building/Unit R-3: 1 & 2 Family Occupancy Dwellings Classification(s) Number of 1 Fireplace(s) Construction Type V-B Grading Required? No Number of Flag or 0 Light Pole(s)? Valuation Details Financial Information Invoice No. PERMIT-BRES2021-078 2 Fee DOOR/WINDOW, RETRO/REPAIR, FIRST 7 HOURLY CHARGE - CITY BUILDING STAFF RECORDS MANAGEMENT FEE - MAJOR DOOR/WINDOW, RETRO/REPAIR, FIRST 7 PC BSAS SB1473 FEE TECHNOLOGY ENHANCEMENT FEE DOOR/WINDOW, RETRO/REPAIR, EA ADDITION 5 FIREPLACE PC FIREPLACE SMI - RESIDENTIAL Total for Invoice PERMIT-BRES2021-0782 Fee Amount Amount Paid $70.03 $70.03 $41.75 $41.75 $21.00 $21.00 $68.36 $68.36 $2.00 $2.00 $5.00 $5.00 $11.67 $11.67 $250.10 $250.10 $166.73 $166.73 $3.90 $3.90 $640.54 $640.54 Grand Total for Permit $640.54 $640.54 Workflow / Inspections Workflow Step / Action Name Inspections v.1 FINAL** v.3 FINAL** v.2 FINAL** v.1 LATH v.1 OKAY TO WRAP v.1 Action Type Inspection Inspection Inspection Inspection Inspection Start Date End Date 11/04/2021 0:00 Printed: 10/24/23 11:04 pm Page 2 of 3 BUILDING PERMIT Permit Type: Permit Number: Property Address: Building Residential BRES2021-0782 80561 VIA SAVONA Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 10/24/23 11:04 pm Page 3 of 3 PERMIT SNAPSHOT REPORT BRES2021-0782 EL is Permit Type Building Residential Work Class: Building Residential Status: Finaled Valuation: $30,000.00 Project: District: Square Feet: Assigned To: City of La Quinta 0.00 Description: SPIRE / REPLACE (10) WINDOWS AND FIREPLACE """ REPLACE (10) WINDOWS ALONG EAST OF DWELLING, RAISE AND LOWER VARIOUS WINDOW HEIGHTS + REMOVE EXISTING FIREPLd AND REPLACE WITH NEW FACTORY -BUILT MASONRY UNIT BY MASON-LITE [CONVENTIONAL LIGHT -FRAME CONSTRUCTION]. THIS PERMIT DOES NOT INCLUDE ELECTRICAL OR ALTERAT TO OTHER AREAS OF THE DWELLING. 2019 CALIFORNIA BUILDING CODES. App Date: Exp Date: Completed: Approval Expire Date: 11/04/2021 NOT AVAILABLE 08/31/2022 03/01/2022 Parcel: 777120005 Main Address: 80561 Via Savona La Quinta, CA 92253 Main Zone: Contractor Applicant Owner GALLAUDET CONSTRUCTION GALLAUDET CONSTRUCTION Jason Spire 54065 AVENIDA DIAZ 54065 AVENIDA DIAZ 80561 Via Savona LA QUINTA, CA 92253 LA QUINTA, CA 92253 La Quinta, CA 92253 Business: (760) 413-7552 Business: (760) 413-7552 Business: (760) 413-7552 Mobile: (760) 413-7552 Mobile: (760) 413-7552 Permit Custom Fields Residential Work Type Remodel Conditioned Square 0 Construction Type V-B Footage Code Edition 2019 Building/Unit R-3: 1 & 2 Family Grading Required? No Occupancy Dwellings Classification(s) Number of 10 Number of Fireplace(s) 1 Number of Flag or Light0 Door/Window Pole(s)? Retrofit/Repair New Electrical Square 0 Footage Attachment File Name BRES2021-0782 - ENERGY REPORT (APPROVED).pdf BRES2021-0782 - PLAN (APPROVED).pdf Added On Added By Attachment Group Notes 03/17/2022 9:16 Fuson, Jake Available Online 03/17/2022 9:16 Fuson, Jake Available Online Inspection Number EGON :220411023 Approved Exterior Lath 052400 Comments: eTRAKiT Inspection Request Inspectors: Clayton, Duane (Primary) ECON:220818010 Disapprove Final Building 155007 d Comments: eTRAKiT Inspection Request Inspectors: Clayton, Duane (Primary) ECON:220825021 Canceled Final Building 639314 Comments: eTRAKiT Inspection Request Inspectors: Clayton, Duane (Primary) ECON:220830122Approved Final Building 210249 Comments: eTRAKiT Inspection Request Inspectors: Clayton, Duane (Primary) JAN:22031605111 Approved Okay to Wrap Status Inspection Type Request Scheduled Start Scheduled End Actual Start Date Actual End Date Date Date Date 04/12/2022 04/12/2022 0:00 04/12/2022 0:00 04/12/2022 0:00 08/19/2022 08/19/2022 0:00 08/19/2022 0:00 08/29/2022 08/29/2022 0:00 08/29/2022 0:00 08/31/2022 08/31/2022 0:00 08/31/2022 0:00 03/17/2022 03/17/2022 0:00 03/17/2022 0:00 08/19/2022 0:00 08/29/2022 0:00 08/31/2022 0:00 03/17/2022 0:00 October 24, 2023 78-495 Calle Tampico Page 1 of 3 PERMIT SNAPSHOT REPORT (BRES2021-0782) 00683 Inspectors: Anaya, Julio (Primary) Note 1. AHI """ Nov 5 2021 1:56PM """ EMAIL REQUESTING ENERGY FOR NEW WINDOWS 2. JFU """ Dec 15 2021 5:37PM """ NOTIFIED APPLICANT OF 1S1 REVIEW COMMENTS VIA EMAIL. 3. 4. 5. JFU """ Feb 1 2022 10:49AM """ 2ND SUBMITTAL RECEIVED V ETRAKIT. JFU """ Feb 17 2022 1:23PM """ LEFT VOICEMAIL WITH APPLICANT TO DISCUSS 2ND REVIEW COMMENTS. JFU """ Feb 28 2022 3:19PM """ NOTIFIED APPLICANT/CONTRACTOR THAT PLANS ARE APPROVED AN PERMIT IS READY TO ISSUE. 6. SPIRE / REPLACE (10) WINDOWS AND FIREPLACE """ REPLACE (10) WINDOWS ALONG EAST SIDE OF DWELLING, RAISE AND LOWER VARIOUS WINDOW HEIGHTS + REMOVE EXISTING FIREPLACE AND REPLACE WITH NEW FACTORY -BUILT MASONRY UNIT BY MASON-LITE [CONVENTIONAL LIGHT -FRAME CONSTRUCTION]. THIS PER DOES NOT INCLUDE ELECTRICAL OR ALTERATIONS TO OTI• AREAS OF THE DWELLING. 2019 CALIFORNIA BUILDING CODES. Created By Aaron Hickson Jake Fuson Jake Fuson Jake Fuson Jake Fuson Jake Fuson Date and Time Created 11/05/2021 0:00 12/15/2021 0:00 02/01/2022 0:00 02/17/2022 0:00 02/28/2022 0:00 02/28/2022 15:09 Invoice No. Fee PERMIT-BRES2021-078:DOOR/WINDOW, RETRO/REPAIR, FIRST 7 HOURLY CHARGE - CITY BUILDING STAFF RECORDS MANAGEMENT FEE - MAJOR DOOR/WINDOW, RETRO/REPAIR, FIRST 7 PC BSAS SB1473 FEE TECHNOLOGY ENHANCEMENT FEE DOOR/WINDOW, RETRO/REPAIR, EA ADDITION 5 FIREPLACE PC FIREPLACE SMI - RESIDENTIAL Total for Invoice PERMIT-BRES2021-0782 Fee Amount $70.03 $41.75 $21.00 $68.36 $2.00 $5.00 $11.67 $250.10 $166.73 $3.90 Amount Paid $70.03 $41.75 $21.00 $68.36 $2.00 $5.00 $11.67 $250.10 $166.73 $3.90 $640.54 $640.54 Grand Total for Permit $640.54 $640.54 Activity Type Other Activity Comments: INCOMPLETE / / / Other Activity Activity Number Name Workflow Action Name ECON:211104113302031ST PERMIT TECH - 1 ETRAKIT (1 DAY) User Aaron Hickson Created On 11/08/2021 AHI:21111509192101191ST BLDG NS - Jake Fuson 12/15/2021 ETRAKIT (1 DAY) Comments: REVISIONS REQUIRED / Dec 15 2021 5:38PM / JFU / •THE U-FACTORS OF THE WINDOWS DON'T MATCH THE ENERGY REPORT (REALLY ONLY THE 3080 WINDOW NEEDS TO BE CHANGED AS ALL OF THE OTHER ONES ARE ACTUALLY MORE EFFICIENT THAN THEY WERI MODELED) • THE LAST SHEET OF THE ENERGY REPORT NEEDS TO BE SIGNED BY JON SCOTT AND YOU • UNABLE TO MATCH THE WINDOWS IN THE ENERGY REPORT WITH THE WINDOWS ON THE PLANS SINCE THE WINDOW SIZES ARE CHAN THE WINDOW SIZES AREN'T ON THE ACTUAL PLANS, AND THE WINDOWS IN THE ENERGY REPORT AREN'T NUMBERED OR NAMED TO CORR WITH THE PLANS. PLEASE ADD THE WINDOW SIZES TO THE PLANS AND LABEL EACH WINDOW #1, #2, ETC OR A, B, C • SPECIFY THE HEADER SIZE AT THE RAISED WINDOWS (ORIGINAL PLANS SHOW 6X6) • DESIGNER MUST SIGN ALL PLAN SHEETS October 24, 2023 78-495 Calle Tampico Page 2 of 3 PERMIT SNAPSHOT REPORT (BRES2021-0782) Other Activity JFU:22020110484702312ND BLDG NS — ETRAKIT (1 WK) Comments: REVISIONS REQUIRED / Feb 17 2022 1:22PM / JFU / -AREAS OF GLAZING IN ENERGY REPORT DON'T MATCH PLANS - SHOW U-FACTORS & SHGC VALUES ON PLANS - WINDOW TAGS DON'T MATCH ENERGY REPORT, (2) WINDOWS LABELED AS "NEW" WITH NO NUMBER TO IDENTIFY WHICH THESE ARE Other Activity JFU:22022803144606093RD BLDG NS — Jake Fuson 02/28/2022 ETRAKIT (1 DAY) Comments: APPROVED / / / Jake Fuson 02/17/2022 Workflow Step / Action Name Inspections v.1 FINAL** v.3 FINAL** v.2 FINAL** v.1 LATH v.1 OKAY TO WRAP v.1 Action Type Inspection Inspection Inspection Inspection Inspection Start Date End Date 11/04/2021 0:00 October 24, 2023 78-495 Calle Tampico Page 3 of 3 BRES2021-0782 REPLACE (10) WINDOWS ALONG EAST SIDE OF DWELLING, RAISE AND LOWER VARIOUS WINDOW HEIGHTS + REMOVE EXISTING FIREPLACE AND REPLACE WITH NEW FACTORY -BUILT MASONRY UNIT BY MASON-LITE [CONVENTIONAL LIGHT -FRAME CONSTRUCTION]. THIS PERMIT DOES NOT INCLUDE ELECTRICAL OR ALTERATIONS TO OTHER AREAS OF THE DWELLING. 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE02/28/2022 By jrr Google Maps CONSTRUCTION HOURS October 1st -April 30 Monday - Friday: 7:00 a.m. to 5:30 p.m. Saturday : 8:00 a.m. to 5:00 p.m. Sunday :None Government Code Holidays: None May 1st - September 30th Monday - Friday: 8:00 a.m. to 7:00 p.m. Saturday : 8:00 a.m. to 5:00 p.m. Sunday None Government Code Holidays: None Construction is NOT PERMITTED in the following Code Holidays: New Yeas Day Dr. Martin Luther king Jr. Day President`; Day Memorial Day Independence Day Labor Day Veteran&Day Thanksgiving Day Christmas Ave "AN ADEQUATELY SIZE❑ ❑EBRIS CONTAINER IS REQUIRED ON THE JOB SITE ❑URING ALL PHASES OF CONSTRUCTION AND MUST BE EMPTIED AS NECESSARY. FAILURE TO DO S❑ MAY CAUSE THE CITY TO HAVE THE CONTAINER DUMPED AT THE EXPENSE OF THE OWNER / CONTRACTOR." Spire Residence Fireplace and Windows Remodel 0 0 52nd Avis wii 5avono Site: 80-561 Via Savona, La Quinta, Ca. 20 ft 11/4/21, 8:40 PM Table of Contents AA -Contents / Site Plan Al -Existing Elevation B1 -Window Schedule / Fireplace Location Cl -New Elevations D1 -Details Scope of permitted work: - Replace existing gas fire place with 60" Masonlite fireplace unit. Gas usage to remain the same. - Replace 10 Windows. Some of the windows suffer from differed -maintenance, and home owner is replacing those in the main living area at this time. Contents/ SPIRE RESIDENCE Gallaudet Construction 80561 Via Savona 54-065Avenida Diaz, La Quinta, Ca. 92253 Site Plan La Quinta, Ca. 92253 (760) 413-7552 tyler@gallaudet.com REVISIONS 4- 44 AA 10/30/21 T.P. ® &REAT RM. TOP OF PIN. FFT FI FVATION SLAB 12 F6 F& TM FRONT COURTYARD FI FVATION SCALE: I/4"=I'-0" T.P. SLAB CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DA,TE02/28/2022 6Y 3� Existing Elevations SPANISH BUNGALOW SCALE: I/4"=1'-O. SPIRE RESIDENCE Gallaudet Construction Elevation Plan 80561 Via Savona 54-065Avenida Diaz, La Quinta, Ca. 92253 (760) 413-7552 tyler@gallaudet.com La Quinta, Ca. 92253 REVISIONS Al 10/30/21 not to scale rr-i I I I I Window # Width Height Area (sgft) U-Factor SHGC Frame 35.5" 83.5" 20.6 0.51 0.196 Aluminum 35.5" 83.5" 20.6 0.51 0.196 Aluminum 35.5" 83.5" 20.6 4 • 35.5" 83.5" 0.51 20.6 0.51 15.5" 58.5" 6.3 15.5" 58.5" 0.196 Aluminum 0.196 0.51 0.196 6.3 0.51 0.196 Aluminum Aluminum Aluminum 8 0 9 35.5" 59.5" 14.7 0.51 59.5" 23.5" 9.7 0.51 59.5" 23.5" 9.7 0.51 53" 55.625" 20.1 0.51 53" 55.625" 20.1 0.51 WALL ABOVE SEE ROOF PLAN Ji iFL ' rI-t ` tr 1 Wet Bar GLO. 10b N >el Covered Patio 19'-I• GLO. I1I II Great Room 9' siizs,/Entry i , 19'-I' GLe I , il I \ is rirs J 0.196 0.196 0.196 0.196 0.196 Aluminum WALL ABOVE SEE ROOF PLAN Aluminum Aluminum Aluminum Aluminum Dinin 10'-I• o 0 Courtyard 1 Garage 2 TeOvw CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DA,TE02/28/2022 By IF 2._5"',,$ Garage 1 TO ENTRY GELL TO ` BARBS 7 ti i mLL iaetO ////////////// 1.-0 12'-2" FI C)C)R PI AN AlfFNfA FLFV C SPIRE RESIDENCE Gallaudet Construction 80561 Via Savona 54-065Avenida Diaz, La Quinta, Ca. 92253 (760) 413-7552 tyler@gallaudet.com La Quinta, Ca. 92253 New Window Schedule I REVISIONS A_ A_ A_ A_ B1 10/30/21 not to scale e GREAT RM. T.P J 61 Y Y 0 TOP OF WIN TP. • GMAT RM. OP OF WIN. T 61 61 61 61 61 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 02/28/2022 By 3- F TIP. 2' New Bifold Corner unit from La Cantina LEFT ELEVATION New Windows by Western SPANISH BUNGALOW d Id 12' New Windows by Western FRONT COURTYARD ELEVATION T.P. SLAB Notes - Replacing 10 windows total, as shown. Windows are by Western, with the exception of the bi-fold corner unit at the bar, by La Cantina. Cut sheets of all are attached. - 3ea. Dining Room windows and Hall window to be extended downward, with the finished sill approximately 6.5" above finished floor to allow for baseboard on the interior. Conventional Framing Standards will be used in lowering the windows. - 2ea. Fireplace wall windows to replaced with clerestory windows to allow for interior shelving re -design, while maintaining the natural light source for the room. Window headers will need to be raised to accommodate clerestory location, new Headers to be 6"x10". - Additional 2x 6 furr wall to be framed inside of the exterior fireplace wall to allow for larger depth of new fireplace and avoid altering the building setback, using conventional framing standards. This wall shall not be load bearing, and have no structural elements. - Fireplace Engineering and cut sheets attached. - Window cut -sheets attached showing sizing and styles. SPIRE RESIDENCE Gallaudet Construction New Elevations 8o561. Via Savona 54-065Av13-75 Diaz, La Quints, dCa.et 92253 (760) 413-7552 tyler@gallaudet.com La Quinta, Ca. 92253 f I REVISIONS A_ A_ A_ A_ Cl 10/30/21 not to scale Fireplace Framing Dimensions A WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. I Figure 10 I Cross -sectional Top View: Combustible Floor Systems NON-COMBUSTIBLE FACING MATERIAL EXTENSION MIN MIN 2" MIN. FROM REAR AND SIDES TO COMBUSTIBLES Fireplace Framing Dimensions: Non -Combustible Floor Systems 1 MiN. CLEARANCE sloEs, REAR AND Top oF FIREPLACE DOME ••IF METAL FRAMING IS USED MAINTAIN A 1/2 INCH MIN. AIR SPACE FROM TOP OF LINTEL. 'IF WOOD FRAMING IS UTILIZED IT MUST BE HELD 18 INCHES MIN. FROM TOP OF LINTEL AND 2INCHES MIN. CLEARANCE MUST BE MAINTAINED ALLAROUND FIREPLACE DOME. MAINTAIN THE 2- CLEARANCE TO COMBUSTIBLES ABOVE THE DOME. DO NOT ATTACH COMBUSTIBLE MATERIALS ON TOP OF THE DOME. Model W MFP-33 41" MFP-39 47" MFP-44 52" MFP-49 57" MFP-63 71" Double Top Plat a 01 10 Lap Double Top Plate min. 4' Fireplace Framing Dimensions I Figure 12 Cross -sectional Top View (Corner Install): Combustible Floor Systems 1 Figure 131 MIN MAINTAINTHE2"CLEARANCE TO COMBUSTIBLES ABOVE THE DOME. DO NOT ATTACH COMBUSTIBLE MATERIALS ON TOP OF THE DOME. NON-COMBUSTIBLE FACING (NOT SUPPLIED). Condition Dim."H"'• with 8" platform 10-1/2" with 8" platform 12-1/2" without platform (non-combustible floors) 4-1/2' MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS ." MEASURED FROM FLOOR TO TOP OF FIREBRICK LINER Top Cripples • 1 n a Header Trimmer— King Stud-. 1 Header Trimmer-c King Stud Sill Studs 5 floor ' .., a , r ' , Q 2009, !me ACI- I odor Rough Opening Window Rough Opening Bottom Plate Conventional Framing Standard Bottom Cripples Model MFP-33 MFP-39 MFP-44 MFP-49 MFP-63 A 70-1/2" 82-1/2" 84-1/4" 86" 91" Not as provided art of fireplace P P MIN or sold by MFl. Where the flooring mate ial at the opening of the fireplace is combustible, it is required that the hearth extension be covered with a non-combustible material. The extension should be set flush against the front of the fireplace front and measure 20" minimum at the front (1'-8" min) and 12" minimum (1'-0" min beyond the sides of the fireplace opening as shown in Figure 10 and 12. If a raised hearth extension is being installed, it must be constructed of non-combustible material and any material under the structure must also be non-combustible. If using a raised hearth or metal base plate, note that a combustible wood header must be no closer than 2" to the top of the dome (see Figure 13). Attention: You will note that there will be a gap between the fireplace front and the extension of the non-combustible hearth material. Be certain that you seal this with non-combustible material. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE02/28/2022 By JF - Conventional 2x6 Framing to be used on non -bearing furr wall. 2x6 stud 16" o.c. - On bearing wall, existing, or same size, window headers to be raised to accommodate clerestory location, with new trimmers; bottom cripples will be replaced accordingly at 16"o.c. Fireplace Framing Dimensions I Figure 14 I Non -Combustible Floor Systems NTAIN CLEARANCE WOOD FRAMING A'o E. MIN DET C.. OOa SECTION A-A • AIRSPACE CLEARANCE TO FETE I Figure 15 I Combustible Floor Systems A-44-1 I Y MIN II LNrr,,l ° II Bongo II I L___ JI H4 H5 A-441-1 F.L,LA104 JOIST DETAIL"C" H3 E. MIN Id ill DET "C" 112' CEMENT H3 • AIRSPACE CLEARANCE TO COMBUSTIBLES SECTION A -A MODEL W1 Hi H2 H3 H4 H5 MFP-33 41" 32-1/2" 56-1/4" 7" 39-1/2" 63-1/4" MFP-39 47" 40-1/2" 64-1/4" 7" 47-1/2" 71-1/4" MFP-44 MFP-49 52" 57" 40-1/2" 40-1/2" 64-1/4" 64-1/4" 7" 7" 47-1/2" 47-12" 71-1/4" 71-1/4" MFP63 71" 42-3/4" 75' 9" 51-3/4" 84• 12 Safety Information WARNING: THIS FIREPLACE HAS NOT BEEN TESTED FOR USE WITH AN UNVENTED GAS LOG SET. TO REDUCE THE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO FIRE- PLACE. WARNING: THIS FIREPLACE HAS BEEN TESTED FOR USE WITH OPTIONAL MASON-LITE GLASS DOORS MFPXX-GD ONLY. WARNING: For MFP-33,39,44: Install only approved, listed UL 103-12" I.D. Class A Chimney System. For MFP-49: Install only approved, listed UL 103-14' I.D. Class A Chimney System. For MFP-63: Install only approved, listed UL 103-16' I.D. Class A Chimney System. Chimney maximum height: 40 feet Chimney minimum height: 14 feet (with offset = 17 feet) 2 offsets maximum. Important: Follow the chimney pipe manufacturer's instructions on the installation of their specific flue system. NOTICE: when installed in Canada, the Mason-lile needs to use ULC S-604 and ULC-610 listed chimney(Only Y Canadian approved chimney) GUIDELINES FOR USE: All current and future users of Mason-Lite Fireplaces are charged with the responsibility for full knowledge of the information contained within this manual which includes: Strict requirements for assembly. Detailed instructions for installation. Cautionary guidelines for use. On -going maintenance instructions. It is the responsibility of the distributor, subcontractor and/or the general contractor - whoever shoulders the liability for installation of this product - to see to it that the work is in complete compliance with the guidelines and instructions in this manual. Note that the general contractor is the party accountable for seeing that adequate clearances are provided from all firebox surtaces per specifications in this manual. DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS FIREPLACE. 13 The Mason-Lite is Designed for Use Only with: - Solid Wood Logs - Plumbed LPG or Natural Gas Log Lighter. - Plumbed ANSI Z21.60 Decorative Gas Log. DO NOT USE OR STORE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR GASES IN OR NEAR THE FIREPLACE) ATTENTION: A fire or an explosion could occur causing property damage, injury or loss of Tide if you do not follow the information in this manual! NOTE: THIS MANUAL MUST BE REPRODUCED ONLY IN ITS ENTIRETY. Before Beginning the Installation Read these instructions carefully before beginning the installation of this fireplace. Also, if installing an ANSI Z21.60 Decorative Gas Log, read the gas log appliance manufacturer's literature regarding sizing and suitability for the installation into this enclosure prior to installation. Statement of Intended Use: The Mason-Lite MasonryFireplace is a modular refractory P is masonry unit designed for field assembly. The firebox is constructed using pre -cast, interlocking refractory blocks. The blocks are then secured to each other using Mortar. The system includes all parts necessary for the assembly of a complete masonry fireplace. In addition to the basic enclosure, a standard 1-1/8" thick, high temperature refractory brick is required to line the interior of the firebox and can be purchased from the manufacturer. These fireplaces are not intended to serve as a primary heat source, rather, the fireplace was expressly created as a supplemental source of heat. The unit is designed for use with solid fuels such as cord wood. WARNING: Any application other than the "Intended Use" as stated above is in violation of the manufacturer's instructions and is hereby prohibited. Such violation may c immediate hazard, property damage or loss of life and will void all liabilities to the manufacturer and will void all warranties explicit or Implied. PROPOSED FIREPLACES SHALL BE PROVIDED WITH THE FOLLOWING: (CENC §150.0(E)) a)CLOSABLE METAL OR GLASS DOORS COVERING THE ENTIRE OPENING OF THE FIREBOX; b)A 6-SQUARE INCH COMBUSTION AIR INTAKE WITH READILY ACCESSIBLE, OPERABLE AND TIGHT -FITTING DAMPER; AND c)A FLUE DAMPER WITH A READILY ACCESSIBLE CONTROL FACTORY -BUILT WOOD -BURNING FIREPLACES SHALL BE TESTED IN ACCORDANCE WITH UL 127 AND SHALL BE QUALIFIED AT THE U.S. EPA'S VOLUNTARY FIREPLACE PROGRAM PHASE 2 EMISSIONS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.5. (CRC R1004.1). DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF CHIMNEYS FOR FACTORY -BUILT FIREPLACES EXCEPT WHERE THE SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY -BUILT FIREPLACE SYSTEM AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SPIRE RESIDENCE Details Gallaudet Construction 80561 Via Savona 54-065Avenida Diaz, La Quinta, Ca. 92253 (760) 413-7552 tyler@gallaudet.com La Quinta, Ca. 92253 REVISIONS A_ A_ A_ A_ D1 10/30/21 not to scale