FSS2020-0159Description: EPIC - STORAGE - NEW FIRE SPRINKLER SYSTEM / BCOM2019-0067 Type: FIRE SPRINKLER (WEB) Subtype: Status: FINALED Applied: 12/11/2020 EPRS COMMERCIAL/INDUSTRIAL Approved: 3/30/2021 KHET Parcel No: 600020028 Site Address: 79315 HIGHWAY 111 STE 1 LA QUINTA,CA 92253 Subdivision: PM 33588 Block: Lot: 2 Issued: 3/30/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 8/24/2021 KHET Valuation: $105,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: La Quinta Self Storage 147 Appl led to Approved —1 Approved to issued I issued to Firialed ADDITIONAL SITES doa CHRONOLOGY TYPE I STAFF NAME I ACTION DATE I COMPLETION DATE I NOTES SENT EMAIL: Cal -West Fire Protection 1113 N. Gates St. Santa Ana, CA 92703 866-374-9378 This email is provided to document the review of the partial Inspection performed today and to additionally give a Notice of Violation. First, the Inspection Review. A partial Overhead Rough/Hydro Inspection was requested for the 2nd Floor addition of piping. Several notes are provided: [1] Installers have installed a total of 9 -heads (1 added) each branch. – Future As-builts should reflect. [2] Seismic Restraint was not installed per updated plans for the 2.5" cross mains. Printed: Friday, February 24, 2023 11:23:27 AM 1 of 24 RWSYSiEMS E-MAIL I KOHL HETRICK 1 5/10/2021 5/10/2021 [3] Mechanical connections did not consistently have "coupons/cookies" attached at all locations. Crew were attempting to locate in discard boxes. #Back-flush (recorded video) will be required if not all accounted for. [4] Air -relief Vent needs to be added for this new section of pipe at the high -point due to the piping arrangement trapping air. Failed/additional inspections as part of inspection phasing will require additional inspection fee of $161.00 each inspection. I have cleared the Partial OH Rough/Hydro in the permit system as this portion of the system is not intended to be covered and can be inspected again as part of a future additional/partial inspection. Thus, avoiding a reinspection specific to this section and requiring fees. Items still need to be addressed. NOTICE OF VIOLATION This "Notice of Violation" is being provided in application to CA Health & Safety Code, Ch 5.5 Automatic Fire Extinguishing Systems Certification, Article 4. Enforcement, § 927. Violations. The SFM, SFM Designee or AHJ is authorized to inspect project worksites where work on fire protection systems is being performed to ensure that persons performing the work possess valid certifications or registrations as required by this Chapter. The SFM, SFM Designee or AHJ is authorized to require persons performing work to provide proof of applicable certification or registration card. Any person who cannot show proof of certification or registration to the SFM, SFM Designee or AHJ shall be subject to Sections 928 through 932. It was observed that Cal -West Fire Protection (CSLB: 870249) had 2 employees present and working at the project location of 79315 Highway 111, La Quinta, CA 92253 under La Quinta Fire Permit FSS2020-0159, performing install work and in violation of the following: H&S § 925. General Provisions. Printed: Friday, February 24, 2023 11:23:27 AM 2 of 24 RWSYSiEMS a) No person shall engage in the installation of water-based fire protection systems as defined in Section 924.12 without first being certified or registered in accordance with these regulations and have obtained a certification or registration card issued by the Office of the State Fire Marshal (OSFM). An Apprentice or Trainee shall become registered in accordance with the provisions in Article 5. H&S § 934. Employer Responsibility. Every properly licensed contractor performing installation of water-based fire protection systems shall ensure all fire sprinkler fitters under their employment are certified or registered. The licensed contractor shall notify the Office of the State Fire Marshal in writing within seventy-two (72) hours from the date of hire of an employee's status as a trainee, apprentice or certificate holder. H&S § 937. Fire Sprinkler Fitter Trainee Registration. d) Individuals may perform work within the scope of these regulations for no more than ninety (90) days prior to submitting an application to the OSFM. e) The trainee shall work under the direct supervision of a Certified Fire Sprinkler Fitter at all times and shall do the following: 1) Only perform installation of water-based fire protection systems for a properly licensed California Contractors State License Board C-16 contractor. 2) Be registered into a California State or federally approved fire sprinkler fitter apprenticeship program within one (1) year of their date of hire. Alejandro Moreno -Diaz (A010634 — Trainee) was identified as "one of the lead" workers on the installation work. There was comments received that the Journeyman level Sprinkler Fitter was not present and was only on the job a couple times a week. Additionally, Moreno-Diaz's certification is well past expired. The second individual (Name not documented) was identified as a "laborer" and was not able to provide any SFM Sprinkler Fitter Certification information. Printed: Friday, February 24, 2023 11:23:27 AM 3 of 24 RWSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 4 of 24 RWSYSiEMS Failure to correct these issues of certification and having qualified individuals performing the work will result in a Stop Work Order, Notification to the State Fire Marshal and possible additional enforcement in compliance with the laws. In the coming days and weeks I will likely perform unannounced site visits and will ask all observable persons performing work on the fire sprinkler system to provide their Sprinkler Fitter Certification Cards. Please confirm receipt of this notice and advise if you have any questions. EMAIL TO CAL -WEST AND GC: Today's inspection was communicated as being the "final" of the rough partials, however there were some rough elements that were yet to be completed, most notably the drops to the elevator hoistway pit with the indicating(tamper) control valve and water flow switch, & the connection of the new portions of the system to the existing risers. A thorough inspection was nevertheless conducted and thorough notes were taken to document changes and missing elements or corrections, where identified. The inspection essentially failed and requires correction with reinspection. Attached you will find the latest plan set with the inspection notes provided in (Purple) notation to stand out from the red piping details. I will attempt to list elements that are corrections requiring reinspection and separately identify elements that are for notation for revised as-builts that will be required for thorough documentation. Corrections: • More than 20 locations were identified as missing the cut- out coupon being affixed in proximity to the connection. (Comment from "Trainee" lead fitter Alejandro Moreno -Diaz that he will go check the truck to see if he could find them - is unsettling. These should be recovered immediately and Printed: Friday, February 24, 2023 11:23:27 AM 4 of 24 RWSYSiEMS E-MAIL I KOHL HETRICK 1 6/7/2021 6/7/2021 affixed next to the connection right away, not stored in a bucket and affixed later.) o Cal West Fire Protection is required to perform systematic backflush actions in phased intervals of the system to reasonably confirm that all cut-out coupons have been recovered. Such flushing operations shall be performed by Sprinkler Fitter classification and in the presence of the General Contractor (Kevin Ham) Following the flushing of the system to the liable comfort of Cal West — Fitter/Management and the pleasure of the General Contractor — Cal West shall provide a letter on company letter head documenting the actions taken and satisfactory results. This letter shall be wet -signed by the Fitter and the General Contractor and then provided to the La Quinta Office of the Fire Marshal for documentation and record keeping. *This is in addition to the check -box detailed in the NFPA 13 Contractor's Material and Test Certificate for Aboveground Piping required as part of System Acceptance. • 2 locations were noted with painted heads — see plans for locations • Several locations were identified as "Missing Head" and confirmed as reasonably needed based on construction elements and required spacing. Install where "Missing Head" is noted. • 2 portions of pipe, affecting 3 heads was twisted — causing the head deflectors to not sit level, but a drastic angle. —see plan for locations • 1 location was identified as needing to be relocated for conduit obstruction — see plan for location • Portions of the main -runs appear to have had seismic installed at dimensions exceeding their maximum spacing. Possibly 2 lengths of 4 -inch have exceeding lateral seismic restraints. • The existing front covered patio now converted to enclosed self -storage space and display windows is still provided with existing sprinkler coverage of unconfirmed density and hazard design. Installation crew does not intend to remove existing and install new portions of system in this location as the plans show, and wants Cal West designers to confirm that Printed: Friday, February 24, 2023 11:23:27 AM 5 of 24 RWSYSiEMS the supply to this portion of the system from the 2nd story supply main is adequate for the Ordinary Group 2 rating. Plans need to clearly identify if this system is to remain, its piping arrangement, pipe size and the 1 or more points of supply. o The plans need to correctly identify the added heads in the 3 window display bays. o Plans also need to correctly identify the existing coverage and head location in the still exterior shade canopy - see noted area on plan. • The 3 -window display bays were drywalled and connection of the new heads was not able to be confirmed even after cutting small access areas. *Cut-out coupon missing was identified at only 1 accessible of these locations. Reinspection needs to be able to adequately show the connection to existing/new overhead lines. • The elevator hoistway pit protection needs to be installed per plan with an indicating control valve and waterflow switch independently supplying the pit sidewall. (x2 locations) • Provide penetration protection in all fire rated assemblies in compliance with NFPA 13 standards and the CBC. • A transition portion of the main of System 1 was not completed per plan. See plan notes for the location of 3 -inch pipe that reduces off of a T -fitting of the 4" main to a 2.5" main. • I forgot to confirm the name of the Cal West Foreman (Jose Moreno, or Gregory Bartholow?) - As the SFM Certified Sprinkler Fitter, they must be present on the job site whenever a Registered Trainee and/or Apprentice (or uncertified) installers are working on the system (CA H&S 937 item (e) / H&S 938 item (c)). Commentary with the Sprinkler Fitter identified that he has not been constant on the job while these uncertified/unregistered Trainees and Apprentices were performing all of the work. Notes for revised As -Built plans to be required: • 4 -inch main piping serving System 1 needs to be corrected to field conditions. — see plan notes for details. Printed: Friday, February 24, 2023 11:23:27 AM 6 of 24 RWSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 7 of 24 RWSYSiEMS • Update sprinkler head legend to reflect the added TY325 Pendents. • Update plans to reflect as -built locations of seismic restraints if compliant with maximum seismic spacing designs. • See plan notes for added and removed heads where identified as appropriate. • See plan notes for pipe routing changes of branch lines in serving specific heads and rerouting around mechanical and architectural details. Thank you, KOHL HETRICK SERIES OF EMAIL IDENTIFYING SYSTEM FITTERS (UNCERTIFIED/UNREGISTERED/REGISTERED): Thank you for the clarification on today's inspection. We will be working with the field and engineering team to get the updated storage unit layout to make sure we have the correct files and submitted for review right away. I also didn't include Jose Camargo and Pedro Osorio on the list since they were not at this project anymore but I do also have an application number for their certifications. Pedro Osorio — CF21006618AES - ( Trainee Application in process for review ) Jose Camargo — CF21006619AES - ( Trainee Application in process for review ) Thanks, Jose Chavez Operations Manager 8361 Commonwealth Ave Buena Park, CA 90621 Printed: Friday, February 24, 2023 11:23:27 AM 7 of 24 RWSYSiEMS Office: (714) 752-6966 Cell: (714) 928-7992 jchavez@cal-westfire.com From: Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov> Sent: Monday, May 17, 20214:59 PM To: J Chavez <jchavez@cal-westfire.com>; Gonzalo Pena <gpena@ca I-westfi re.com> Cc: Cooley, Sonia@CALFIRE <Sonia.Cooley@fire.ca.gov> Subject: RE: EPIC STORAGE - LA QUINTA - 5-10-2021 PARTIAL INSPECTION Thank you for the list and the update. On May 11th I visited the job site and requested identification from the pipe fitters observed there at that time. I was provided ID's for — Ernesto Carrillo, Jose Camargo & Pedro Osorio Villeda. I see Ernesto in your list. Please identify provisions for Jose and Pedro. For clarification of today's inspection attempt: 1. Overhead Rough/Hydro — Partial inspection for the 1st floor additions to the system were not approved. 2. Significant modifications made in the field that were not compliant with the approved (revised) plans dated 5/4/2021. Portions of the mains were rerouted and moved to deal with architectural impacts. 3. It appeared that the field installers were not provided the current approved set of plans and were following the original approved plans for the seismic restraint installation locations. This is of minor concern as the seismic installed is excessive to what was approved in the revised set. 4. There was no attempt by the installing crew to maintain Printed: Friday, February 24, 2023 11:23:27 AM 8 of 24 RWSYSiEMS E-MAIL KOHL HETRICK 5/17/2021 5/17/2021 red -line notes of changes to the piping arrangement that would be able to be sent back to company designers for updating as -built plans. S. No Fire Sprinkler plan set is showing the current/updated storage unit layout which has modestly changed. Seek updated layout from the Architect. 6. The existing canopy front area that has now been enclosed was not improved as the plans had identified. Field installers were trying to justify the existing pendant coverage as adequate. You need to confirm that the existing coverage is (1) supplied and charged, (2) is of appropriate calculation for Ordinary Hazard Group -II if you would like to keep the existing coverage. a. If not keeping, portion of system should be demoed/improved per approved plans. b. As-builts shall reflect either option. 7. All fitters on site shall produce documentation or card showing their status with the State Fire Marshal for Pipe Fitter Certification. Please let me know if you have any questions. Thank you, KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal Cal Fire/Riverside County Fire Department City of La Quinta CAL FIRE/Riverside County Fire Department Desk: 760-777-7074 1 Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov I www.rvcfire.org Sch: Mon-Thurs Leadership, Competence, Integrity, Safety, Customer Service The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its Printed: Friday, February 24, 2023 11:23:27 AM 9 of 24 RWSYSiEMS employees to serve our community through innovation and partnership. From: J Chavez <jchavez@cal-westfire.com> Sent: Monday, May 17, 202112:04 PM To: Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov>; Gonzalo Pena <gpena@cal-westfire.com> Cc: Cooley, Sonia@CALFIRE <Sonia.Cooley@fire.ca.gov> Subject: RE: EPIC STORAGE - LA QUINTA - 5-10-2021 PARTIAL INSPECTION Warning: this message is from an external user and should be treated with caution. Good Afternoon Inspector Hetrick, Per our conversation earlier this morning, please see below the information requested on the crew members that are working onsite that have the pipe fitter cards and those that are on the trainee application list that we have started working on getting thru to the Cal -Fire website for approval. Gregory Bartholow — A010656 ( Renewal fees have been paid Santos A. Mayorga — A7010 ( Renewal fees have been paid ) Alejandro Moreno -Diaz - A010634 ( Application has been submitted as a Sprinkler Fitter. Had previously completed trainee ) Jose Moreno — A023080 ( Valid Sprinkler Fitter Card ) Ernesto Carrillo — CF21006824EAS ( Trainee Application in process for review ) Hansy Discua — CF21006823EAS ( Trainee Application in process for review ) Alexander Moreno — CF21006634 ( Trainee Application in process for review ) Thanks, Jose Chavez Printed: Friday, February 24, 2023 11:23:27 AM 10 of 24 WSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 11 of 24 RWSYSiEMS Operations Manager 8361 Commonwealth Ave Buena Park, CA 90621 Office: (714) 752-6966 Cell: (714) 928-7992 jchavez@cal-westfire.com From: Hetrick, Kohl@CALFIRE Sent: Tuesday, July 13, 20219:19 AM To: Kevin Ham Subject: 79215 Hwy 111- LQ - Fire Sprinkler Corrosion Concerns Attachments: NFPA 25 -14.2 Internal Insp of Piping.pdf; NFPA 25 - ANNEX D - OBSTRUCTION INVESTIGATION.pdf; FSS2019-0145 - PERMIT DETAILS.pdf Kevin, Thank you for bringing to my attention the additional existing system leak issues. I had already observed some and even directed the need for CalWest to reasonably mitigate. I'm sorry to hear that they are merely putting a band-aid on the long-term issue. This building has been suspected to have had MIC (Micro- biologically Influenced Corrosion) in the fire sprinkler system since my observation of it on 10/23/2019. 1 observed it while inspecting work related to the neighboring tenant's construction improvements. I gave direction to that General Contractor to have a licensed C-16 Contractor to perform a needed NFPA 25 5 -Year Certification of the system. The contractor acquired local company Desert Fire who certified the system at that time. I personally cautioned Desert Fire on certifying the system E-MAIL KOHL HETRICK 7/13/2021 7/13/2021 prior to confirming points of corrosion throughout the 4 -riser systems and overhead mains and cross -mains. Desert Fire representative advised that they were comfortable with Printed: Friday, February 24, 2023 11:23:27 AM 11 of 24 RWSYSiEMS OFFICE MEETING I KOHL HETRICK 1 7/13/2021 7/13/2021 certification. I am presently contacting Desert Fire and requesting the formal documentation of the work/repairs/certification performed, as I had not previously been provided. It may be appropriate for Property Management/Owner to reach out to Desert Fire with the information of continued leaks and corrosion issues in existing portions of the system that they Certified under liability. Alternatively, a C-16 Fire Protection Contractor may be tasked with performing a whole system investigation for other areas of corrosion or obstruction concerns. Attached are excerpts from NFPA 25, the standard for maintaining these systems. Annex D provides good information on the impacts and concerns of corrosion, especially that of MIC. I have also provided the Permit Details for the Floor & Decor permit which has my correspondence on this matter highlighted on page 3. Please let me know if you have any questions. Thank you, KOHL HETRICK Kevin (Superintendent with Colorado West Construction) requested that I visit the site due to concerns with failing portions of the existing system. Kevin advised that they have had a total of 3 leaks in the system due to observed MIC internal pipe corrosion. Cal West Fire Protection went out and did minor pipe replacement repairs. I will be discussing property owner and tenant improvement contractor options for addressing the long-term issue. Last 5 -year was completed by Desert Fire as part of a corrosion mitigation concern under previous FSS2019-0145 for the neighboring tenant Floor & Decor. 5 -year certification posted 10/2019. Printed: Friday, February 24, 2023 11:23:27 AM 12 of 24 WSYSiEMS PRE -CON KOHL HETRICK I 4/12/2021 I 4/12/2021 I M individuals that have theirpSFM Sprinkler Fitter 'ca ds. 2 Discussed project expectations and timelines. CONDITIONS Printed: Friday, February 24, 2023 11:23:27 AM 13 of 24 RWSYSiEMS R L: INFORMATION 'I CLTD NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT Jose Chavez 8361 Commonwealth Ave Buena Park CA 90621 (714)497-7227 CHECK # jchavez@cal- westfire.com BILL TO CAL - WEST FIRE PROTECTION SPECIALIST 1113 N GATES STREET SANTA ANA CA 92703 (714)497-7227 GPENA@CAL- WESTFIRE.COM CONTRACTOR CAL - WEST FIRE PROTECTION SPECIALIST 1113 N GATES STREET SANTA ANA CA I 92703 I (714)497-7227 I I GPENA@CAL- I WESTFIRE.COM OWNER ROB FOX 44045 MARGARITA ROAD, SUITE 100 TEMECULA CA 92592 (714)497-7227 $161.00 $161.00 Printed: Friday, February 24, 2023 11:23:27 AM 13 of 24 RWSYSiEMS FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIRE FAILED OR ADDITIONAL RE- 101-0000-42421 0 $161.00 $161.00 5/25/21 WEB8335 182287 CREDIT Jose Chavez EPRS INSPECTION FIRE FAILED OR ADDITIONAL RE- 101-0000-42421 0 $161.00 $161.00 5/25/21 WEB8335 182287 CREDIT Jose Chavez EPRS INSPECTION FIRE FAILED OR ADDITIONAL RE- 101-0000-42421 0 $161.00 $161.00 7/27/21 WEB8842 132999 CREDIT Jose Chavez EPRS INSPECTION FIRE FAILED OR ADDITIONAL RE- 101-0000-42421 0 $161.00 $161.00 8/23/21 WEB9088 161264 CREDIT Jose Chavez EPRS INSPECTION FIRE MORE THAN 3 REVIEWS - EACH 101-0000-42420 1 $161.00 $161.00 3/30/21 WEB7770 182825 CREDIT Jose Chavez EPRS REVIEW Printed: Friday, February 24, 2023 11:23:27 AM 13 of 24 RWSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 14 of 24 WSYSiEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID Y BY FIRE PLAN REVISION 101-0000-42420 0 $161.00 $161.00 4/27/21 WEB8058 115176 CREDIT Jose Chavez EPRS SUBMITTALS FIRE PLAN REVISION 101-0000-42420 0 $161.00 $161.00 7/28/21 WEB8853 130407 CREDIT Jose Chavez EPRS SUBMITTALS FIRE SPRINKLER SYSTEMS 101-0000-42421 0 $242.00 $242.00 3/30/21 WEB7770 182825 CREDIT Jose Chavez EPRS COMMERCIAL/INDUSTR IAL FIRE SPRINKLER SYSTEMS 101-0000-42420 0 $403.00 $403.00 3/30/21 WEB7770 182825 CREDIT Jose Chavez EPRS COMMERCIAL/INDUSTR IAL PC Total Paid for FIRE FEES: $1,772.00 $1,772.00 RECORDS 101-0000-424160 $10.00 $10.00 3/30/21 WEB7770 182825 CREDIT Jose Chavez EPRS MANAGEMENT FEE Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY 502-0000-436110 $5.00 $5.00 3/30/21 WEB7770 182825 CREDIT Jose Chavez EPRS ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:00 $1,787.00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES 777F DATE DATE Printed: Friday, February 24, 2023 11:23:27 AM 14 of 24 WSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 15 of 24 RWSYSiEMS 5/10/2021 - Partial OH Rough/Hydro Inspection: (1) Branches have 9 heads (1 added) each. (2) Seismic Restraint was not installed per updated plans. (3) Mechanical connections did not have "coupons/cookies" attached at all locations. Crew attempting to locate in discard boxes. OVERHEAD HYRO KHET 5/10/2021 5/10/2021 PARTIALLY PARTIAL - 2ND FLOOR Back-flush required if not all accounted for. APPROVED ADD. (4) Air -relief Vent needs to be added for this new section of pipe at the high -point due to the piping arrangement trapping air. *Two crew -members on site do not have valid/current SFM Sprinkler Pipe Fitter Certification cards. **No (Journeyman) Sprinkler Fitter classification was on site. 5/10/2021 - Partial OH Rough/Hydro Inspection: (1) Branches have 9 heads (1 added) each. (2) Seismic Restraint was not installed per updated plans. (3) Mechanical connections did not have "coupons/cookies" attached at all locations. Crew attempting to locate in discard boxes. OVERHEAD ROUGH KHET 5/10/2021 5/10/2021 PARTIALLY PARTIAL - 2ND FLOOR Back-flush required if not all accounted for. PIPING APPROVED ADD. (4) Air -relief Vent needs to be added for this new section of pipe at the high -point due to the piping arrangement trapping air. *Two crew -members on site do not have valid/current SFM Sprinkler Pipe Fitter Certification cards. **No (Journeyman) Sprinkler Fitter classification was on site. SIGNIFICANT AS -BUILT CHANGES OBSERVED OVERHEAD HYRO KHET 5/17/2021 5/17/2021 DISAPPROVE PARTIAL - 1ST FLOOR AND REQUIRE REVISIONS/CALCS PRIOR TO D REINSPECTION Printed: Friday, February 24, 2023 11:23:27 AM 15 of 24 RWSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 16 of 24 RWSYSiEMS OVERHEAD ROUGH PIPING KHET 5/17/2021 5/17/2021 DISAPPROVE D PARTIAL - IST FLOOR SIGNIFICANT AS -BUILT CHANGES OBSERVED AND REQUIRE REVISIONS/CALCS PRIOR TO REINSPECTION OVERHEAD HYRO KHET 6/7/2021 6/7/2021 APPROVED 1ST FLOOR SYSTEM Corrections: • More than 20 locations were identified as missing the cut-out coupon being affixed in proximity to the connection. (Comment from "Trainee" lead fitter Alejandro Moreno -Diaz that he will go check the truck to see if he could find them - is unsettling. These should be recovered immediately and affixed next to the connection right away, not stored in a bucket and affixed later.) o Cal West Fire Protection is required to perform systematic backflush actions in phased intervals of the system to reasonably confirm that all cut-out coupons have been recovered. Such flushing operations shall be performed by Sprinkler Fitter classification and in the presence of the General Contractor (Kevin Ham) Following the flushing of the system to the liable comfort of Cal West — Fitter/Management and the pleasure of the General Contractor — Cal West shall provide a letter on company letter head documenting the actions taken and satisfactory results. This letter shall be wet -signed by the Fitter and the General Contractor and then provided to the La Quinta Office of the Fire Marshal for documentation and record keeping. *This is in addition to the check -box detailed in the NFPA 13 Contractor's Material and Test Certificate for Aboveground Piping required as part of System Acceptance. • 2 locations were noted with painted heads Printed: Friday, February 24, 2023 11:23:27 AM 16 of 24 RWSYSiEMS OVERHEAD ROUGH PIPING KHET 6/7/2021 6/7/2021 DISAPPROVE D SEE NOTES & ATTACHMENTS — see plans for locations • Several locations were identified as "Missing Head" and confirmed as reasonably needed based on construction elements and required spacing. Install where "Missing Head" is noted. • 2 portions of pipe, affecting 3 heads was twisted — causing the head deflectors to not sit level, but a drastic angle. — see plan for locations • 1 location was identified as needing to be relocated for conduit obstruction — see plan for location • Portions of the main -runs appear to have had seismic installed at dimensions exceeding their maximum spacing. Possibly 2 lengths of 4 -inch have exceeding lateral seismic restraints. • The existing front covered patio now converted to enclosed self -storage space and display windows is still provided with existing sprinkler coverage of unconfirmed density and hazard design. Installation crew does not intend to remove existing and install new portions of system in this location as the plans show, and wants Cal West designers to confirm that the supply to this portion of the system from the 2nd story supply main is adequate for the Ordinary Group 2 rating. Plans need to clearly identify if this system is to remain, its piping arrangement, pipe size and the 1 or more points of supply. o The plans need to correctly identify the added heads in the 3 window display bays. o Plans also need to correctly identify the existing coverage and head location in the still exterior shade canopy - see noted area on plan. Printed: Friday, February 24, 2023 11:23:27 AM 17 of 24 RWSYSiEMS I• The 3 -window display bays were drywalled and connection of the new heads was not able to be confirmed even after cutting small access areas. *Cut-out coupon missing was identified at only 1 accessible of these locations. Reinspection needs to be able to adequately show the connection to existing/new overhead lines. • The elevator hoistway pit protection needs to be installed per plan with an indicating control valve and waterflow switch independently supplying the pit sidewall. (x2 locations) • Provide penetration protection in all fire rated assemblies in compliance with NFPA 13 standards and the CBC. • A transition portion of the main of System 1 was not completed per plan. See plan notes for the location of 3 -inch pipe that reduces off of a T -fitting of the 4" main to a 2.5" main. • I forgot to confirm the name of the Cal West Foreman (Jose Moreno, or Gregory Bartholow?) - As the SFM Certified Sprinkler Fitter, they must be present on the job site whenever a Registered Trainee and/or Apprentice (or uncertified) installers are working on the system (CA H&S 937 item (e) / H&S 938 item (c)). Commentary with the Sprinkler Fitter identified that he has not been constant on the job while these uncertified/unregistered Trainees and Apprentices were performing all of the work. Printed: Friday, February 24, 2023 11:23:27 AM 18 of 24 WSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 19 of 24 RWSYSiEMS ALL CORRECTIONS HAVE BEEN MADE. AS- BUILTS REQUIRED. CERTIFICATION OF BACKFLUSH OF OVERHEAD PIPING TO REMOVE UN -RETRIEVED DEBRIS IS REQUIRED. *ALL OH ROUGHS/HYDROS HAVE BEEN COMPLETED. **DISCUSSED FINAL OVERHEAD ROUGH KHET 6/9/2021 6/9/2021 APPROVED INSPECTION, ACCEPTANCE TESTING AND PIPING CERTIFICATIONS THAT ARE REQUIRED. (C-16 GONZALO WAS PRESENT AND ENSURED COMPLIANCE OF THE SYSTEM AND RED -LINE NOTING OF THE PLANS FOR FUTURE AS - BUILTS) 1 -AIR VENT REQUIRED 2ND FLOOR SYSTEM 1. 1) Install Auxiliary drain signage where missing. 2) Reconnect the disconnected pipe feeding the exterior projection fire sprinkler. 3) Add missing protection in unit on 2nd floor near SW stairway. 4) Address concern for over -spray throughout 1st floor where perceived FIRE FINAL** KHET 7/29/2021 7/29/2021 DISAPPROVE SEE NOTES barriers were not provided. D 5) Restock spare head box with all appropriate head types and quantities. 6) *Mesh screen needed to be installed on all 1st floor units to maintain 18" of clearance from the fire sprinkler head. Reinspection is required and will followup with paperwork or certification. FIRE FINAL** KHET 8/24/2021 1 8/24/2021 1 APPROVED ALL ITEMS ADDRESSED Printed: Friday, February 24, 2023 11:23:27 AM 19 of 24 RWSYSiEMS 1ST FIRE (2 WK) KOHL 12/11/2020 12/29/2020 12/28/2020 REVISIONS REQUIRED SEE ATTACHMENTS HETRICK Attachment Type CREATED OWNER DESCRIPTION 1ST PERMIT TECH (1 ARMANDO 12/11/2020 12/14/2020 12/18/2020 COMPLETE IST SUBMITTAL - PLAN La Quinta Self Storage - DAY) MAGALLON DOC 12/14/2020 EtrakitContractor 2ND FIRE (1 WK) KOHL 1/11/2021 1/18/2021 1/25/2021 REVISIONS REQUIRED SEE ATTACHMENTS HETRICK 1ST SUBMITTAL - 3RD FIRE (1 WK) KOHL 2/22/2021 3/1/2021 3/3/2021 REVISIONS REQUIRED SEE ATTACHMENTS 12/11/2020 EtrakitPublicReg HETRICK CALCULATIONS 1ST FLR. 1 4TH FIRE (1 WK) KOHL 3/24/2021 3/31/2021 3/30/2021 APPROVED SEE ATTACHMENTS AREA 1.PDF HETRICK AREA 1 5TH FIRE (1 WK) KOHL 4/26/2021 5/3/2021 5/4/2021 APPROVED REV 5 - AS BUILTS HETRICK HYDRAULIC 1ST FIRE (1 WK) KOHL 5/25/2021 6/2/2021 6/1/2021 APPROVED REVISION - 6 - AS- HETRICK CALCULATIONS 1ST FLR. BUILTS 2ND FIRE (1 WK) KOHL 7/19/2021 7/27/2021 7/28/2021 APPROVED REVISION 7 - AS AREA 1 HETRICK BUILTS BOND INFORMATION Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED IST SUBMITTAL - PLAN La Quinta Self Storage - DOC 12/14/2020 EtrakitContractor 1 SET Fire Sprinkler Plans.pdf 1ST SUBMITTAL - HYDRAULIC DOC 12/11/2020 EtrakitPublicReg HYDRAULIC CALCULATIONS 1ST FLR. 1 CALCULATIONS 1ST FLR. AREA 1.PDF AREA 1 IST SUBMITTAL - HYDRAULIC DOC 12/11/2020 EtrakitPublicReg HYDRAULIC CALCULATIONS 1ST FLR. 1 CALCULATIONS 1ST FLR. AREA 2.PDF AREA 1 Printed: Friday, February 24, 2023 11:23:27 AM 20 of 24 WSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 21 of 24 WSYSiEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED IST SUBMITTAL - HYDRAULIC DOC 12/11/2020 EtrakitPublicReg HYDRAULIC CALCULATIONS 1ST FLR. 1 CALCULATIONS 1ST FLR. AREA 3.PDF AREA 1 1ST SUBMITTAL - HYDRAULIC DOC 12/11/2020 EtrakitPublicReg HYDRAULIC CALCULATIONS 2ND 1 CALCULATIONS 2ND FLR. AREA 1.PDF FLR. AREA 1 IST SUBMITTAL - HYDRAULIC DOC 12/11/2020 EtrakitPublicReg HYDRAULIC CALCULATIONS 2ND 1 CALCULATIONS 2ND FLR. AREA 2.PDF FLR. AREA 1 1ST SUBMITTAL - HYDRAULIC DOC 12/11/2020 EtrakitPublicReg HYDRAULIC CALCULATIONS 2ND 1 CALCULATIONS 2ND FLR. AREA 3.PDF FLR. AREA 1 La Quinta Self Storage - DOC 1/11/2021 EtrakitPublicReg 2nd Submittal- Plan Set Fire Sprinkler Plans Rev. 1 Rev.1-FIRE COMMENTS 1.pdf Hydraulic Calculations Hydraulic Calculations DOC 1/11/2021 EtrakitPublicReg 1 Rev. 1 Rev. 1. pdf La Quinta Self Storage - LA QUINTA SELF DOC 2/22/2021 EtrakitPublicReg Fire Sprinkler Plan Rev. STORAGE REV.2 FIRE 1 2 SPRINKLER PLAN.pdf La Quinta Self Storage - LA QUINTA SELFSTORAGE DOC 2/22/2021 EtrakitPublicReg Hydraulic Calculations REV.2 1 HYDRAULIC Rev.2 CALCULATIONS.pdf FSS2020-0159 - 2nd PC - DOC 2/22/2021 EtrakitPublicReg Correction Letter CORRECTIONS LETTER - 1 Response RESPONSE LETTER.pdf Printed: Friday, February 24, 2023 11:23:27 AM 21 of 24 WSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 22 of 24 WSYSiEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED FSS2020-0159 - 3rd PC - DOC 3/24/2021 EtrakitPublicReg Correction Letter CORRECTIONS LETTER 1 Response RESPONSE.pdf La Quinta Self Storage - LA QUINTA SELF DOC 3/24/2021 EtrakitPublicReg Hydraulic Calculations STORAGE REV. 4 1 Rev. 4 HYDRAULIC CALCS.pdf La Quinta Self Storage - LA QUINTA SELF DOC 3/24/2021 EtrakitPublicReg Fire Sprinkler Plan Rev. STORAGE REV. 4 - FIRE 1 4 SPRINKLER PLANS.pdf LA QUINTA SELF DOC 4/26/2021 EtrakitPublicReg REV 5 - AS -BUILT FIRE STORAGE AS BUILT - 1 SPRINKLER PLANS FIRE SPRINKLER PLAN.pdf REV 5 - AS -BUILT - LA QUINTA SELF DOC 4/26/2021 EtrakitPublicReg HYDRAULIC STORAGE AS -BUILT - 1 CALCULATION HYDRAULIC CALCS.pdf LA QUINTA SELF DOC 4/26/2021 EtrakitPublicReg REV 5 - AS -BUILT - STORAGE AS -BUILT - 1 SEISMIC BRACING SEISMIC CALCS.pdf HYDRAULIC HYDRAULIC DOC 5/25/2021 EtrakitPublicReg CALCULATIONS AREA 1- CALCULATIONS AREA 1- 1 4 4.pdf LA QUINTA SELF DOC 5/25/2021 EtrakitPublicReg FIRE SPRINKLER PLAN - STORAGE - AS -BUILT 1 AS -BUILT REVISION REVISION.pdf FIRE SPRINKLER LA QUINTA SELF DOC 7/19/2021 EtrakitPublicReg DRAWINGS - ASBUILT STORAGE - AS -BUILT 1 REV. 2 REV. 2.pdf HYDRAULIC LA QUINTA SELF DOC 7/19/2021 EtrakitPublicReg CALCULATIONS AS- STORAGE -HYDRAULIC 1 BUILT REV. 2 CALCS REV. 2.pdf Printed: Friday, February 24, 2023 11:23:27 AM 22 of 24 WSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 23 of 24 WSYSiEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED FSS2020-0159 - IST PC - FSS2020-0159 - IST PC - DOC 12/28/2020 KOHL HETRICK CORRECTIONS CORRECTIONS 1 LETTER.pdf LETTER.pdf DOC 12/28/2020 KOHL HETRICK HYDRAULIC CALC HYDRAULIC CALC 1 PLATE.pdf PLATE.pdf CALFIRE - Sprinkler CALFIRE - Sprinkler DOC 12/28/2020 KOHL HETRICK Fitter Certification 2019 Fitter Certification 2019 1 (IB 18-014).pdf (IB 18-014).pdf DOC 12/28/2020 KOHL HETRICK FSS2020-0159 - 1ST PC - FSS2020-0159 - 1ST PC - 1 PLAN CORRECTIONS.pdf PLAN CORRECTIONS.pdf FSS2020-0159 - 2nd PC - FSS2020-0159 - 2nd PC - DOC 1/25/2021 KOHL HETRICK CORRECTIONS CORRECTIONS 1 LETTER.pdf LETTER.pdf FSS2020-0159 - 3RD PC - FSS2020-0159 - 3RD PC - DOC 3/3/2021 KOHL HETRICK FIRE PLAN FIRE PLAN 1 CORRECTIONS.pdf CORRECTIONS.pdf FSS2020-0159- FSS2020-0159- DOC 3/30/2021 KOHL HETRICK APPROVED PLANS AND APPROVED PLANS AND 1 CALCS.pdf CALCS.pdf DOC 3/30/2021 KOHL HETRICK FSS2020-0159 - COA FSS2020-0159 - COA 1 AND JOB CARD.pdf AND JOB CARD.pdf DOC 4/12/2021 KOHL HETRICK 4-12-2021 - EMAIL - 4-12-2021 - EMAIL - 1 MOU UPDATE.pdf MOU UPDATE.pdf DOC 5/4/2021 KOHL HETRICK FSS2020-0159 - REVISED FSS2020-0159 - REVISED 1 PLANS APPROVED.pdf PLANS APPROVED.pdf DOC 5/10/2021 KOHL HETRICK FSS2020-0159 - 5-10- FSS2020-0159 - 5-10- 1 2021- INSP NOTES.pdf 2021- INSP NOTES.pdf FSS2020-0159 - AS- FSS2020-0159 - AS - DOC 6/1/2021 KOHL HETRICK BUILT REVISIONS - BUILT REVISIONS - 1 APPROVED 6-1-2021.pdf APPROVED 6-1-2021.pdf Printed: Friday, February 24, 2023 11:23:27 AM 23 of 24 WSYSiEMS Printed: Friday, February 24, 2023 11:23:27 AM 24 of 24 WSYSiEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/7/2021 KOHL HETRICK FSS2020-0159 - 6-7-2021 FSS2020-0159 - 6-7-2021 1 INSP NOTES.pdf INSP NOTES.pdf FSS2020-0159 - FINAL FSS2020-0159 - FINAL DOC 7/28/2021 KOHL HETRICK AS-BUILTS-CALCS - AS-BUILTS-CALCS - 1 APPROVED.pdf APPROVED.pdf DOC 7/29/2021 KOHL HETRICK FSS2020-0159 - 7-29- FSS2020-0159 - 7-29- 1 2021 - INSP NOTES.pdf 2021 - INSP NOTES.pdf FSS2020-0159 - 7-29- FSS2020-0159 - 7 -29 - DOC 7/29/2021 KOHL HETRICK 2021 - Insp Corrections 2021 - Insp Corrections 1 flat.pdf flat.pdf Printed: Friday, February 24, 2023 11:23:27 AM 24 of 24 WSYSiEMS ALwFCM IeYnIC NRK{LlAlltlw malMl-F.MtiI.�r11�.w.MM.. n.+�....w-,.oll..y� �•�: Pte' �M ���� �..-ti..- Yom. 6••'7� -_ ..... �. _ ..r. �...: -�- '�,y- � rr- tgcc No.ro ryr:.ro .e'..bw m�.w.R www.. Kym.. �•�: Pte' �M ���� ^ter^ --_. cxm;u c 1 ryca �_•-•-- Kym.. �•�: Pte' �M ���� ^ter^ --_. •-z c 1 .s' Iltaakr5erles' LF67�IF ev s EXISTING UNDERGROUND FOR REFERNECE ONLY 1� O 0 O I x Q ----------------------- NOTE: GENERAL NOTE: ALL WORK ON FIRE PROTECTION SYSTEMS 1 1 SHALL BE PERFORMED ONLY BY INDIVIDUALS POSSESING A VALID CASFM 1 1 FIRE SPRINKLER FITTERCERTIFICATION. ; 1 PON REQUEST BY THE AUTHORITY HAVING1 JURISDICTION, INDIVIDUALS SHALL 1 1 PROVIDE SUCH PROOF OF CERTIFICATION. 1 PROJECT DIRECTORY: O�epa mmt=f Building and Safely Fire Safety It. -, IN.- VICINITY Iywv_