BMCH2021-0298Description: JOHNSTON / HVAC CHANGE OUT Type: MECHANICAL - HVAC Subtype: Status: ISSUED Applied: 8/19/2021 ECON CHANGEOUT (WEB) Approved: 8/20/2021 AHI Parcel No: 762130008 Site Address: 80361 RIVIERA LA QUINTA,CA 92253 Subdivision: TR 28340-2 Block: Lot: 21 Issued: 8/26/2021 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $9,682.00 Occupancy Type: Construction Type: Expired: 2/22/2022 AMA No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: HVAC CHANGE OUT - 16 SEER/ 80 AFUE SPLIT SYSTEM. LIKE FOR LIKE NO CHANGE OF LOCATION. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2019 CALIFORNIA BUILDING CODES. Printed: Thursday, December 28, 2023 1:22:10 PM 1 of 3 WSYSiEMS CHRONOLOGY NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT IE INC - NICOLE LEWIS 31225 LA BAYA WESTLAKE VILLAGE ca 91362 (760)601-3500 nlewis@ipermitca.com CONTRACTOR HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS CA 92276 (760)601-3500 FRANCISCO@CALLTHE GENERAL.COM OWNER HARLAN JOHNSTON 80361 RIVIERA La Quinta Ca 92276 (760)601-3500 Printed: Thursday, December 28, 2023 1:22:10 PM 1 of 3 WSYSiEMS DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 8/26/21 WEB9140 63215447224 CREDIT AEC1021 ECON Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: HVAC CHANGEOUT - 101-0000-42402 0 $40.25 $40.25 8/26/21 WEB9140 632147224 CREDIT AEC1021 ECON SPLIT -SYSTEM 54 HVAC CHANGEOUT - 101-0000-42600 0 $80.50 $80.50 8/26/21 WEB9140 632147224 CREDIT AEC1021 ECON SPLIT -SYSTEM PC 54 Total Paid for MECHANICAL CHANGEOUT 2019: $120.75 $120.75 PERMIT ISSUANCE 101-0000-424040 $101.97 $101.97 8/26/21 WEB9140 632 7224 CREDIT AEC1021 ECON 5 Total Paid for PERMIT ISSUANCE: $101.97 $101.97 RECORDS 101-0000-424160 $10.00 $10.00 8/26/21 WEB9140 632147224 CREDIT AEC1021 ECON MANAGEMENT FEE 54 Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY 502-0000-436110 $5.00 $5.00 8/26/21 WEB9140 632147224 CREDIT AEC1021 ECON ENHANCEMENT FEE 54 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS: REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS DATE REMARKS NOTES 1ST PERMIT TECH — PERMIT TECH 8/19/2021 8/20/2021 8/20/2021 COMPLETE ETRAKIT (1 DAY) BUCKET Printed: Thursday, December 28, 2023 1:22:10 PM 2 of 3 WsYsrEMS Printed: Thursday, December 28, 2023 1:22:10 PM 3 of 3 WsYsrEMS CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) CF1R-ALT-02-E (Page 1 of 3) Project Name: HARLAN JOHNSTON I Date Prepared: 2021-08-18 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF111-ALT-02 document for each dwelling unit. 01 Project Name HARLAN JOHNSTON 02 Date Prepared 2021-08-18 03 Project Location 80361 Riviera 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name HARLAN JOHNSTON Name Location or Area SC System (ft) ucted system? ducted Dwelling Unit Conditioned Floor system 07 Zip Code 92253 08 Area (ft) 4200 component? components? Number of Space Conditioning LO9 Climate Zone 15 10 (SC) Systems in this Dwelling 1 1 Unit: Altered space B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 SC System ID or SC System CFA served by this Is the SC system a Installing a refrigerant Installing new SC Installing more Installing entirely Installing entirely Name Location or Area SC System (ft) ucted system? ducted containing system than 40 feet of new duct system? new SC system? Alteration Type Served component? components? ducts? Altered space System 1 Location 1 4200 Yes Yes Yes No No No conditioning syste m C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 421-A020122555A-000-000-0000000-0000 Registration Date/Time: 2021-08-18 12:18:04 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.005 Report Generated: 2021-08-18 12:23:37 Schema Version: rev 20210501 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 13 SC System Heating Cooling Description Altered Heating Minimum Altered Cooling Minimum Required New or System ID/ of Area Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct Name Served System Type Components Type Value System Type Components Type Value Type Duct Length R -Value All new All new N/A - no System 1 Location 1 Central gas heating AFUE 0.8 Central split cooling SEER 16 Setback ducts n/a furnace components AC components replaced. Indoor coil Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15 percent or <= 10 percent leakage to outside, or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. Exceptions: Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25. Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 421-A020122555A-000-000-0000000-0000 Registration Date/Time: 2021-08-18 12:18:04 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.005 Report Generated: 2021-08-18 12:23:37 Schema Version: rev 20210501 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Nicola Schleehauf N I. wlzu S Company: Signature Date: iPermit 2021-08-18 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive City/State/Zip: Phone: Westlake Village CA 91362 818-735-7876 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Patrick Somers Patr6ckl Soinews- Company : Date Signed: General Air Conditioning 2021-08-18 Address: License: 31170 Reserve Drive 686310 City/State/Zip: Phone: Thousand Palms CA 92276 760-343-7488 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 421-A020122555A-000-000-0000000-0000 Registration Date/Time: 2021-08-18 12:18:04 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.005 Report Generated: 2021-08-18 12:23:37 Schema Version: rev 20210501