BRES2022-0028Description: JOHNSTON / [1] FRENCH DOOR CHANGE OUT
Type: BUILDING RESIDENTIAL
Subtype: REMODEL
Status: FINALED
Applied: 1/12/2022 ECON
(WEB)
Approved: 1/13/2022 AHI
Parcel No: 762130008 Site Address: 80361 RIVIERA LA QUINTA,CA 92253
Subdivision: TR 28340-2
Block:
Lot: 21
Issued: 1/14/2022 AHI
Lot Sq Ft: 0
Building Sq Ft: 0
Zoning:
Finaled: 2/28/2022 MHU
Valuation: $2,500.00
Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0
No. Unites: 0
Details:
I ADDITIONAL SITES
45 1
1
I Applied to Approved
Approved to Issued
Issued to Finaled
Printed: Thursday, December 28, 2023 1:17:40 PM 1 of 3
WSYSiEMS
IIIIIIIIIIIIq
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
Francisco Dimas
22982 Alcalde Drive,
Suite 100
Laguna Hills
CA
92653
(
Printed: Thursday, December 28, 2023 1:17:40 PM 1 of 3
WSYSiEMS
7= --
PARENT PROJECTS
Printed: Thursday, December 28, 2023 1:17:40 PM 2 of 3
WsYsrEMS
SEQID
INSPECTION TYPE INSPECTOR
SCHEDULED
DATE
COMPLETED RESULT
DATE
REMARKS
NOTES
■
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
LOS ANGELES
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
1/26/22
WEB10507
635019052
CREDIT
CUSTOM WINDOWS
ECON
25
INC DBA RENEW
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00
BSA:
RECORDS
LOS ANGELES
MANAGEMENT FEE -
101-0000-42416
0
$21.00
$21.00
1/14/22
WEB10391
634807734
CREDIT
CUSTOM WINDOWS
ECON
60
MAJOR
INC DBA RENEW
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00
LOS ANGELES
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
1/14/22
WEB10391
634807734
CREDIT
CUSTOM WINDOWS
ECON
ENHANCEMENT FEE
60
INC DBA RENEW
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
DOOR/WINDOW,
634807734
LOS ANGELES
101-0000-42400
0
$70.03
$70.03
1/14/22
WEB10391
CREDIT
CUSTOM WINDOWS
ECON
RETRO/REPAIR, FIRST 7
60
INC DBA RENEW
DOOR/WINDOW,
LOS ANGELES
RETRO/REPAIR, FIRST 7
101-0000-42600
0
$68.36
$68.36
1/14/22
WEB10391
634807734
CREDIT
CUSTOM WINDOWS
ECON
60
PC
I
I
I
I
I
I
I
I
I INC DBA RENEW
Total Paid for WINDOW/SLIDING GLASS
$138.39 $138.39
DOOR/FENESTRATION 2021:
•
7= --
PARENT PROJECTS
Printed: Thursday, December 28, 2023 1:17:40 PM 2 of 3
WsYsrEMS
SEQID
INSPECTION TYPE INSPECTOR
SCHEDULED
DATE
COMPLETED RESULT
DATE
REMARKS
NOTES
FINAL" MHU
2/28/2022
2/28/2022 APPROVED
7= --
PARENT PROJECTS
Printed: Thursday, December 28, 2023 1:17:40 PM 2 of 3
WsYsrEMS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
STATUS
REMARKS
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
DATE
1ST PERMIT TECH —
PERMIT TECH
DOC
1/13/2022
AARON HICKSON
1/12/2022
1/13/2022
1/13/2022
COMPLETE
2116581 Plot plan.pdf
2116581 Plot plan.pdf
ETRAKIT (1 DAY)
BUCKET
DOC
1/12/2022
Etrakit Contractor
Application
Johnston 2116581
Printed: Thursday, December 28, 2023 1:17:40 PM 3 of 3
WsYsrEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
(APPROVED)Johnston
(APPROVED)Johnston
DOC
1/13/2022
AARON HICKSON
1
2116581 Plot plan.pdf
2116581 Plot plan.pdf
DOC
1/12/2022
Etrakit Contractor
Application
Johnston 2116581
1
Aplication.pdf
DOC
1/12/2022
Etrakit Contractor
Plot plan
Johnston 2116581 Plot
1
plan.pdf
DOC
1/12/2022
Etrakit Contractor
(APPROVED) CF1R
Johnston 2116581
1
CF1R.pdf
DOC
1/12/2022
Etrakit Contractor
HOA
Johnston 2116581
1
HOA.pdf
Printed: Thursday, December 28, 2023 1:17:40 PM 3 of 3
WsYsrEMS
I
I
BRES2022-0028 / 80361 RIVIERA
CITY OF LA QUINT,
BUILDING DIVISION i
REVIEWED FOR i
CODE
COMPLIANACEL,
DATE 1 _'j1 3/20223Y fl*1If I
M rr%I A/^r r-41 rl rTrI Pl r—TT
F\ L— r- LPY %,- L— L 1 J r\ L— 1 rw s 1 1 ,
FRENCH DOOR AT FRONT
OF DWELLING. THIS
PERMIT DOES NOT
INCLUDE ANY i
ALTERATIONS TO i
EXISTING i
PENETRATIONS. 2019
CALIFORNIA BUILDING
CODES i
1 - STORY SFD
I I
I ;
I i
-------------------- RIVIERA-----------------------I,-
I I
4ata was calculatefl using the winww 51 computer program wim P1rnL Ydllmaum SPELrral vola mR.
CaUlaGorts based on 3j8" gaP, 3mm [11g") glass, and a gas 911 levelof WK {Argon or ttrypton; unless noted
otherwise (e.g. "Air oArtnnll. HIM &a -Parke use 3/8" and 1/480s.
Winter arW.%mmer NFRQASHRAE environmental co".dltlons used forcaleuladons. Comfort Indoor Glass
Temperature s are for the center portlon of the glass.
Window And Door
Replacement
ALL WORK SHALL CONFORM TO THE
2019 CALIFORNIA BUILDING CODE
2019 CALIFORNIA ELECTRICAL CODE
2019 CALIFORNIA MECHANICAL CODE
2019 CALIFORNIA RESIDENTIAL CODE
For Energy Efficiency Per CRC310.2.5
U -Factor 0.30 SHGC 0.23
SMOKE & CARBON MONOXIDE ALARMS
Smoke Alarms in All Bedrooms and Halls
Carbon Monoxide Alarms Outside All Sleeping
Areas - CRC R315.2_3 & R314.1_3
All Bedrooms Must Have At Least One
Window Or Door Opening Directly To The
Exterior Meeting This Criteria:
Minimum Clear Width =20"
Minimum Clear Height = 24"
Min. Area = 5.7 Sq. Ft. ( 5.0 Sq. Ft. For
Grade Floor Residential )
Maximum Sill Height = 44"
STUCCr
AND Is
ExISTIN
MANAGEMENT ME
STUCCO FLASHIh
BEHIND WATER P.
A MINIMUM OF 1"
ANDERSEN SEALAI
JAMB
MANUFACTURERS APPROVED ENTRY DOOR/ FRENCH DOOR DETAIL
Door
. Cardinal Rl
f.
Superior Glass Products
ENERGY PERFORMANCE
RATINGS
Wactor (us/ 1-P
Solar Heat Gain Coefficient
0,24
0.22
ADDITIONAL PERFORMANCE RATINGS
Visible Light
Reflectance
Reflectance
Transmittance
Out
In
66%
11%
12
4ata was calculatefl using the winww 51 computer program wim P1rnL Ydllmaum SPELrral vola mR.
CaUlaGorts based on 3j8" gaP, 3mm [11g") glass, and a gas 911 levelof WK {Argon or ttrypton; unless noted
otherwise (e.g. "Air oArtnnll. HIM &a -Parke use 3/8" and 1/480s.
Winter arW.%mmer NFRQASHRAE environmental co".dltlons used forcaleuladons. Comfort Indoor Glass
Temperature s are for the center portlon of the glass.
Window And Door
Replacement
ALL WORK SHALL CONFORM TO THE
2019 CALIFORNIA BUILDING CODE
2019 CALIFORNIA ELECTRICAL CODE
2019 CALIFORNIA MECHANICAL CODE
2019 CALIFORNIA RESIDENTIAL CODE
For Energy Efficiency Per CRC310.2.5
U -Factor 0.30 SHGC 0.23
SMOKE & CARBON MONOXIDE ALARMS
Smoke Alarms in All Bedrooms and Halls
Carbon Monoxide Alarms Outside All Sleeping
Areas - CRC R315.2_3 & R314.1_3
All Bedrooms Must Have At Least One
Window Or Door Opening Directly To The
Exterior Meeting This Criteria:
Minimum Clear Width =20"
Minimum Clear Height = 24"
Min. Area = 5.7 Sq. Ft. ( 5.0 Sq. Ft. For
Grade Floor Residential )
Maximum Sill Height = 44"
STUCCr
AND Is
ExISTIN
MANAGEMENT ME
STUCCO FLASHIh
BEHIND WATER P.
A MINIMUM OF 1"
ANDERSEN SEALAI
JAMB
MANUFACTURERS APPROVED ENTRY DOOR/ FRENCH DOOR DETAIL
Door
Win.
Room
Size
Existing
Size
New
Egress
Win
Total
Sq. Ft.
D1
Drawn By: Francisco Dimas
CASITA
74 x 90 FR.DR.
74 x 90 French Door - Tempered
XX SLIDER -SLIDER XO SLIDER -FIXED
46
AWN AWNING WINDOW DH DOUBLE HUNG
SH SINGLE HUNG PDS PATIO DOOR SLIDER
Total 46
Name Charles & Mary Johnston
Address 80361 Riviera
Renewal by Andersen LLC.
City, Zip La Quinta, 92253
22982 Alcalde Drive, Suite 100
Phone 703-963-8010
Laguna Hills, CA 92653
Year Built 2000
(714) 259-5120 LIC. 990416
Drawn By: Francisco Dimas
RF#: 2170814
LEGEND:
J013:2116581 gc
XX SLIDER -SLIDER XO SLIDER -FIXED
GW GARDEN WINDOW CST CASEMENT PIX PICTURE WINDOW
AWN AWNING WINDOW DH DOUBLE HUNG
SH SINGLE HUNG PDS PATIO DOOR SLIDER
RBA Renewal By Andersen Dual Glaze Low - E -4 Windows
SCOPE of WORK:
Replace 1 french door with new french door into existing opening. Like for like.
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CERTIFICATE OF COMPLIANCE
entia
Protea Name: JOHNSTON
rations That Do Not Require HERS Field Verification
Date Prepared: 1/12/2022
MMISSIONO
CF 1R -ALT -05-E
Page 1 of 4
This compliance document is only applicable to simple alterations that do not require HERS verification for compliance. When HERS verification is required, a CF1R-ALT- 01 shall first be registered
with a HERS Provider Data Registry.
Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CFIR-ALT-05 and CF2R- ALT -05 Compliance Documents. Possible exemptions from duct
leakage testing include: less than 40 ft of ducts were added or replaced; or the existing duct system was insulated with asbestos; or the existing duct system was previously tested and passed by a
HERS Rater. If space conditioning systems are altered and are not exempt from HERS verification, then a CFIR-ALT-02 must be completed and registered with a HERS Provider Data Registry.
Alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R -value greater than 5.8 per inch, or Open Cell Spray
Polyurethone Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cubic foot having an R -value of 3.6 per inch, shall complete and register a CF1R-ALT-01 with a HERS Provider Data
Registry.
If more than one person has responsibilityfor installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are
responsible. Alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be met.
Temporary labels shall not be removed before verification by the building inspector.
A. General Information
01
Project Name:
JOHNSTON
02
Date Prepared:
1/12/2022
03
Project Location:
80361 RIVIERA
04
Building Front Orientation (deg or cardinal):
05
CA City:
LA QUINTA
06
Number of Altered Dwelling Units:
07
Zip Code:
92253
08
Fuel Type:
09
Climate Zone:
15
10
Total Conditioned Floor Area (ft):
11
Building Type:
Single Family
12
Slab Area (ft)
13
Project Scope (Select all that apply):
❑ B. Insulation
❑ D. & E. Fenestration/Glazing - ADD
❑ G. Space Conditioning System (Heating, Cooling, Duct system) ❑ Lighting
❑ C. Roof Replacement ❑✓ D. & F. Fenestration/Glazing - REPLACE ❑ H. Water Heating System ❑ Include Mandatory Measures?
CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2020
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CFI R -ALT -05-E (Revised 01/20) _ CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE CF1R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification Page 2 of 4
Project Name: JOHNSTON
Date Prepared: 1/122022
D. Fenestration/Glazing Allowed Areas and Efficiencies (Section 150.2(b)1)
01 02 03 04 05
06
07
Maximum
Maximum
Existing
r No
17
Net Added Fenestration Area (all orientations)
I
18
Is Net Added Fenestration Area 5 0 for all orientations?
Allowed
Allowed
Fenestration
Existing
Maximum
Maximum
Maximum
Maximum
0.30
Fenestration
West -Facing
for All
West -Facing
Allowed
Allowed
Allowed
Allowed
23
Alteration
for All
Fenestration
Orientations
Fenestration
U -Factor
U -Factor
SHGC
SHGC
Type
Orientations (ft2)
Area Only (ft2)
(ft2)
Area (ft2)
(Windows)
(Skylights)
(Windows)
(Skylights)
Comments
F. Fenestration/Glazing Proposed Areas and Efficiencies - Replace (Section 150.2(b)1B)
Note: Doors with greater than or equal to 25 percent glazed area are considered glazed doors and are treated as fenestration
products.
01 02 03 l 04 05 06 07 08
09
1 10
11
12 13 14
Area Area Net
Proposed
Proposed Combined
Fenestration Dynamic Orientation Removed Added Added Proposed U -factor
Proposed
SHGC Exterior SHGC from
Tag/ID Type Frame Type Glazing (N, S, W, E) (ft2) (ft2) Area (ft2) U -factor
Source
SHGC
Source Shading Device CF1R-ENV-03
D1 Operable Non-metalN 46 46 0
0.29
NFRC
0.21
NFRC
ii
Add Row Delete Row I
15
Net Added West -facing Fenestration Area
16
Is Net Added Fenestration Area:5 for west -facing fenestration?
r Yes
r No
17
Net Added Fenestration Area (all orientations)
18
Is Net Added Fenestration Area 5 0 for all orientations?
r Yes
i' No
19
Proposed Fenestration U -factor (Windows)
0.29
20
Required Fenestration U -factor (Windows)
0.30
21
Is the proposed Fenestration U -factor 5 the Required Fenestration U -factor?
i Yes
r No
22
Proposed Fenestration SHGC (Windows)
0.21
23
Required Fenestration SHGC (Windows)
0.23
24
Is the Proposed Fenestration SHGC15 the Required Fenestration SHGC?
4 Yes
r No
25
Proposed Fenestration U -factor (Skylights)
26
Required Fenestration U -factor (Skylights)
27
Is the proposed Fenestration U -factor 5 the Required Fenestration U-factor?l
C Yes
r No
CA Building Energy Efficiency Standards - 2019 Residential Compliance
January 2020
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
'-do
GEG-GFIR-ALT-05-E (Revised 01/20) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE CF111-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification Page 3 of 4
Project Name: JOHNSTON Date Prepared: 1/12/2022
28 Proposed Fenestration SHGC
29 Required Fenestration SHGC
30 Is the Proposed Fenestration SHGC:s the Required Fenestration SHGC? r Yes r No
CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2020
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CFiR-ALT-05-E {Revised 01120)
CERTIFICATE OF COMPLIANCE
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
P.Ject Name: JOHNSTON
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
accurate and complete.
Name:
rartdisco Dimas
F�
Ili I.
CALIFORNIA ENERGY COMMISSION*
CF1R-ALT-05-E
Oat. Prepared: 1/12/2022
Page 4 of 4
RENEWAL BY ANDERSEN OF ORANGE COUNTY „a„—.`
_1 /22/2022 _
Address: CEA/ HERS Certification Identification lirapplicablei:
22982 ALCALDE DR., SUITE 100
City/State/Zip: - phone:
LAGUNA HILLS, CA 92653 714-259-5120
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of
Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency
for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building
owner at occupancy. _ Ji
Res ... cihi. nnci— N.— —
RENEWAL BY ANDERSEN OF ORANGE COUNTY
22982 ALCALDE DR., SUITE 100
LAGUNA HILLS, CA 92653
Responsible Designer Signature:
Date Signed:
License:
990416
Phone:
714-259-5120
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300.
CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2020
Daily requests
Here's a daily digest of the community's requests!
PGA West it Residential Assoc.
-1 -2022
Door replacement
Created by Mary Ellen Johnston (Address K 361 - " T RA.)
The entr y door to our casita is deteriorated and
needs to be replaced. We Would like L <.. .
Nikki Roye ep ied.
Hi Mrs. Johnston, If you are replacing the door like for
like no application is necessary. If...
Nikki Royer replied:
Request changed to In process
Nikki Royer replied:
Request changed to Closed
■'� ��w
---('EM ofdh DESERT
PERMIT #
PLAN LOCATION:
Project Address: 80361 Riviera
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 1 french door with new french door into
Garage
existing opening. Like for like change out.
Applicant Name: Francisco Dimas
Patio/Porch
Address:22982 Alcalde Dr
Email:
City, ST, Zip: Laguna Hills, CA 92653
SF
Telephone: 949-273-1390
Email: francisco.dimas@andersencorp.com
Valuation of Project S 2500
Contractor Name: Renewal by Andersen of Orange County
New SFD Construction:
Address:
Address: 22982 Alcalde Drive
Conditioned Space
SF
City, St, Zip Laguna Hills Ca 92653
Garage
SF
Telephone: 714-259-5120
Patio/Porch
SF
Email:
Fire Sprinklers
SF
State Lic: 990416 City Bus Lic: 0112063
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Construction Type: Occupancy:
Telephone:
Bedrooms:
Stories:
# Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name: Chales & Mary Johnston
New Commercial / Tenant Improvements:
Address: 80361 Riviera
Total Building SF
City, ST, Zip La QUinta, CA 92253
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
Reed
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM 10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License