BELC2023-1051BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 11/15/2023 ISSUED DATE: 11/16/2023 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Electrical 81180 LEGENDS WAY BELC2023-1051 762310004 Lot 25 MB 285/51 TR 28838-1 AMENDED $20,000.00 RL, 25 Owner:Stephanie McCartney Applicant:MDESIGN GROUP - mariano ramirez 75145 St Charles Place #3, Palm Desert, CA 92211 Contractor:MARGARET A VARGAS 73000 Shadow Mountain Dr, Palm Desert, CA 92260 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 11/16/23 10:26 pm Page 1 of 4 Permit Type: Permit Number: Property Address: Electrical BELC2023-1051 81180 LEGENDS WAY BUILDING PERMIT construction lender preliminary notice from that duty. Printed: 11/16/23 10:26 pm Page 2 of 4 Permit Type: Permit Number: Property Address: Electrical BELC2023-1051 81180 LEGENDS WAY BUILDING PERMIT 400A ELECTRICAL SERVICE CHANGE OUT [200A EXISTING] SURGE PROTECTION DEVICE REQUIRED PER CEC 230.67, A TYPE 1 OR 2 SPD SHALL BE INSTALLED PRIOR TO RELEASE BEING SENT TO UTILITY. THIS PERMIT DOES NOT INCLUDE RELOCATION OF EQUIPMENT OR ANY OTHER WORK. 2022 CALIFORNIA BUILDING CODES. Use of Permit Construction Details 200Existing Service(AMP)400NewService(AMP)NoYes/No RLZoning LDRGeneral Plan Within La Quinta LimitsCity Limits TR 28838-1 AMENDEDSubdivision Name 25Lot Number 93586Centerlines 2125.29Lot Size Lot 25 MB 285/51 TR 28838-1 AMENDED Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00002455 $8.00 Technology Enhancement Fee $8.00 $30.51 Service Changeout / Upgrade $30.51 $21.36 Service Changeout / Upgrade PC $21.36 $115.94 Permit Issuance $115.94 $1.00 Building Standards Administration $1.00 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $4.72 Credit Card Convenience Fee $4.72 $193.53 $193.53 Total for Invoice INV-00002455 Grand Total for Permit $193.53 $193.53 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Review v.1 11/15/2023 0:00 Permit Tech Review v.1 Receive Submittal 11/15/2023 0:00 11/15/2023 15:39 Issue Permit v.1 11/15/2023 15:44 11/16/2023 14:26 Verify Contractor info & Conditions have been met v.1 Generic Action 11/15/2023 15:44 Verify & Invoice Fees v.1 Generic Action 11/16/2023 14:24 Verify Fee Payment & Issue Permit v.1 Generic Action 11/16/2023 14:26 Print, Attach, and Email Building Permit v.1 Create Report 11/16/2023 14:26 11/16/2023 14:26 Inspections v.1 Electrical Underground v.1 Inspection Rough Electrical v.1 Inspection Temp Use of Permanent Power v.1 Inspection Final Inspections v.1 Final Electrical v.1 Inspection Printed: 11/16/23 10:26 pm Page 3 of 4 Permit Type: Permit Number: Property Address: Electrical BELC2023-1051 81180 LEGENDS WAY BUILDING PERMIT Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 11/16/23 10:26 pm Page 4 of 4 PERMIT SNAPSHOT REPORT BELC2023-1051 FOR CITY OF LA QUINTA Electrical 11/15/2023App Date:Project:Permit Type City of La QuintaService Changeout/Upgrade 11/27/2024Exp Date:District:Work Class: 0.00Issued NOT COMPLETEDCompleted:Square Feet:Status: Description: Valuation: 400A ELECTRICAL SERVICE CHANGE OUT [200A EXISTING] SURGE PROTECTION DEVICE REQUIRED PER CEC 230.67, A TYPE 1 OR 2 SPD SHALL BE INSTALLED PRIOR TO RELEASE BEING SENT TO UTILITY. THIS PERMIT DOES NOT INCLUDE RELOCATION OF EQUIPMENT OR ANY OTHER WORK. 2022 CALIFORNIA BUILDING CODES. $20,000.00 Assigned To:Approval Expire Date:11/16/2023 Parcel:Main762310004 Address:81180 Legends Way La Quinta, CA 92253 Main Zone: Applicant MDESIGN GROUP - mariano ramirez 75145 St Charles Place #3 Palm Desert, CA 92211 Business: (760) 219-3068 Applicant MDESIGN GROUP - mariano ramirez 75145 St Charles Place #3 Palm Desert, CA 92211 Business: (760) 219-3068 Owner Stephanie McCartney Home: (760) 219-3068 Contractor MARGARET A VARGAS 73000 Shadow Mountain Dr Palm Desert, CA 92260 Business: (818) 669-0713 Permit Custom Fields Existing Service(AMP)200 NewService(AMP)400 Yes/No No Zoning RL General Plan LDR City Limits Within La Quinta Limits Subdivision Name TR 28838-1 AMENDED Lot Number 25 Centerlines 93586 Lot Size 2125.29 Legal Description Lot 25 MB 285/51 TR 28838-1 AMENDED Attachment File Name Added On Added By Attachment Group Notes Signature___11/15/2023.jpg 11/15/2023 14:38 ,Uploaded via CSS SITE PLAN - NOT APPROVED SET.pdf 11/15/2023 15:39 Mendez, Deisy Other Misc Documents SITE PLAN APPROVED.pdf 11/15/2023 15:41 Mendez, Deisy Available Online APPROVED SITE PLAN *LQ Building Permit.pdf 11/16/2023 14:26 Service, EnerGov Available Online Building Permit at time of issuance Inspection Number Status Inspection Type Actual End DateActual Start DateScheduled End Date Scheduled Start Date Request Date IBLD-007881-202 3 Disapprove d Rough Electrical 11/28/2023 11/28/2023 0:00 11/28/2023 0:00 11/28/2023 10:01 11/28/2023 10:05 Inspectors: Hunt, Mark (Primary) Checklist Item Description Passed Comments Correction Correction No NOT READY, NEW PANEL IS NOT ON SITE Correction Correction No A 400A MAIN SERVICE PANEL IS WIDER THAN THE EXISTING PANEL AND REQUIRES REFRAMING AN EXTERIOR LOAD BEARING SHEAR WALL, PROVIDE DETAIL FROM THE ENGINEER OF RECORD SHOWING THE SEISMIC FIX Created ByNote Date and Time Created 1.Deisy MendezUNABLE TO ROUTE THE FRAMING PLANS SINCE THIS IS AN ELECTRICAL PERMIT - ADVISED TO SUBMIT THE FRAMING CHANGES UNDER THE BRES2021-0095 PERMIT FOR REVIEW AND APPROVAL 01/04/2024 8:57 Invoice No.Amount PaidFeeFee Amount INV-00002455 $8.00 Technology Enhancement Fee $8.00 $30.51 Service Changeout / Upgrade $30.51 $21.36 Service Changeout / Upgrade PC $21.36 $115.94 Permit Issuance $115.94 $1.00 Building Standards Administration $1.00 Page 1 of 278-495 Calle TampicoJanuary 09, 2024 PERMIT SNAPSHOT REPORT (BELC2023-1051) $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $4.72 Credit Card Convenience Fee $4.72 $193.53 $193.53 Total for Invoice INV-00002455 Grand Total for Permit $193.53 $193.53 Condition Description Date Created Satisfied Contractor Information & Business License 11/15/2023 YesContractor Information & Business License Owner-Builder Acknowledgment and Verification 11/15/2023 YesOWNER BUILDER PACKET AND COPY OF DRIVER LICENSE REQUIRED Comments: Pulled as contractor Sub-Contractor List 11/15/2023 YesSUB-CONTRACTOR LIST REQUIRED FOR OWNER BUILDERS Comments: Pulled as contractor Submittal Name Status Received Date Due Date Complete Date Resubmit Completed ApprovedPermit Tech Review v.1 11/15/2023 11/16/2023 11/15/2023 No Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Permit Tech Review (1 Day)HUB Complete 11/15/2023 11/16/2023 11/15/2023 Comments: APPROVED BY JF Workflow Step / Action Name Action Type Start Date End Date Review v.1 11/15/2023 0:00 Permit Tech Review v.1 Receive Submittal 11/15/2023 0:00 11/15/2023 15:39 Issue Permit v.1 11/15/2023 15:44 11/16/2023 14:26 Verify Contractor info & Conditions have been met v.1 Generic Action 11/15/2023 15:44 Verify & Invoice Fees v.1 Generic Action 11/16/2023 14:24 Verify Fee Payment & Issue Permit v.1 Generic Action 11/16/2023 14:26 Print, Attach, and Email Building Permit v.1 Create Report 11/16/2023 14:26 11/16/2023 14:26 Inspections v.1 11/27/2023 0:00 Electrical Underground v.1 Inspection Rough Electrical v.1 Inspection 11/27/2023 0:00 11/28/2023 10:06 Rough Electrical v.2 Inspection 11/28/2023 0:00 Temp Use of Permanent Power v.1 Inspection Final Inspections v.1 Final Electrical v.1 Inspection Page 2 of 278-495 Calle TampicoJanuary 09, 2024 METER / MAIN MAIN 400 AMP CONDUIT PER IID /SCE M #3 CU GROUND TO UFER 1/0 CU TO GAS & WATER GENERAL LIGHTING AT 3W/ S.F. 3W / 3,886 S.F.=11,658 SMALL APPLIANCE CIRCUITS AT 1,500W EA.2/ 1,500 =3,000 VENT HOOD AT 750W EA.1/ 750 = 750 LAUNDRY CIRCUIT AT 1,500W EA.1/ 1,500 = 1,500 DISHWASHER AT 1,500W EA.1/ 1,500 = 1,500 DRYER AT 5,400W EA.1/ 5,400 = 5,400 EXISTING POOL EQUIPMENT 1X / 5,760 = 5,760 SUBTOTAL =29,568 1ST 10,000W AT 100%= 10,000 REMAINING AT 40%= 7,828 6.0 TONS REQUIRED AT 2,016W / TON 2,016W/ 10 TONS = 20,016 TOTAL = 37,844 MAIN SERVICE: 37,844W / 240V = 157 AMPS USE 400AMP MAIN PANEL - CONTRACTOR TO VERY MINIMUM REQUIREMENTS E1.10 ELECTRICAL LAYOUT IS SCHEMATIC AND CAN BE RECONFIGURED BY GENERAL CONTRACTOR. ELECTRICAL NOTES PANEL DIAGRAM 21/4" = 1'-0" SCALE ELECTRICAL CALCULATIONS 31/4" = 1'-0" SCALE ELECTRICAL NOTES 11/4" = 1'-0" SCALE ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E R EPRODUCED OR MODIFIED IN ANY WAY WITHOUT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY D OE S N OT R E LE ASE I N AN Y WAY THE COPYR IGHT AN D OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST SUBMITTAL 11/15/2023 220083 SHEET NAME DESIGNER OWNER STEPHANIE MCCARTNEY ADDRESS 81180 LEGENDS WAY LA QUINTA, CA 92253 PROJECT TYPE PANEL UPGRADE REVISIONS NO.DESCRIPTION DATE 75145 ST CHARLES PLACE #3 PALM DESERT, CA 92211 T: 760-219-3068 C: 760-219-3068 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M DANIEL GRIFFITH 1. ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS (NEW, MODIFIED, REPLACED, OR EXTENDED) SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT OR BY ANY OF THE OTHER MEANS DESCRIBED IN 210.12(A)(2) THROUGH (6). (CEC 210.12(A)) 2. ALL INTERIOR AND EXTERIOR LIGHT FIXTURES SHALL BE A HIGH EFFICACY TYPE FIXTURE AND HAVE A CONTROL DEVICE / SYSTEM IN ACCORDANCE WITH THE 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS / TITLE 24, SECTION 150.0(K)) 3. KITCHEN RECEPTACLES AT KITCHEN COUNTER SHALL BE INSTALLED ABOVE THE SPLASH OR DIRECTLY IN THE SPLASH IF THE SPLASH EXTENDS ABOVE 6". GFCI RECEPTACLES SHALL BE INSTALLED EVERY 48" ON CENTER. COORDINATE ALL LOCATIONS PRIOR TO INSTALLING ROUGH-IN-BOXES. 4. PROVIDE RECEPTACLE FOR THE MICROWAVE APPLIANCE. PROVIDE DEDICATED 20AMP CIRCUIT. 5. RECEPTACLES FOR REFRIGERATOR SHALL BE INSTALLED +48" ABOVE FINISHED FLOOR. PROVIDE A 20AMP DEDICATED CIRCUIT FOR EACH APPLIANCE. 6. MOUNT SWITCHES AND CONVENIENCE OUTLETS AT KITCHEN, BATHROOMS, AND LAUNDRY ROOM COUNTERS HORIZONTALLY AT 40" ABOVE SLAB TO CENTER OF PLATE. 7. ALL FIXED APPLIANCES SHALL BE SECURELY FASTEN IN PLACE. 8. PROVIDE AT LEAST TWO 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS TO SERVE KITCHEN, BREAKFAST ROOM, AND DINING ROOM. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. 9.FOR GARBAGE DISPOSAL AND DISHWASHER, INSTALL A HALF SWITCHED DUPLEX RECEPTACLE AND INSTALL BELOW SINK. CONNECT THESWITCHED SIDE OF THE RECEPTACLE TO A MOTOR RATED WALL SWITCH OR TO THE SINK MOUNTED AIR SWITCH AND PROVIDE A DEDICATED CIRCUIT FOR EACH APPLIANCE WITH A COMMON TRIP DEVICE. 10.PROVIDE A JUNCTION BOX WITH PROPER SUPPORTS FOR PENDANT LIGHT FIXTURES. 12.MOUNT CONVENIENCE RECEPTACLES HORIZONTALLY WITH BOTTOM OF BOX 3' ABOVE SLAB. 13.ALL CONVENIENCE OUTLETS TO BE ON GFI SEPARATE FROM INTERIOR G.F.I. PROTECTED CIRCUITS. 14.TYPICAL LIGHT SWITCH MOUNTING HEIGHT TO BE 37" ABOVE SLAB TO CENTER OF PLATE. MOUNT SWITCHES AND CONVENIENCE OUTLETS AT KITCHEN, BATHROOMS, AND LAUNDRY ROOM COUNTERS HORIZONTALLY AT 40" ABOVE SLAB TO CENTER OF PLATE. 15.ALL SMOKE DETECTORS & CARBON MONOXIDE ALARMS ARE TO REMAIN. IF ANY ARE TO BE REPLACED, PROVIDE A INVENSYS "FIREX" 12000 SERIES "FADCM" SMOKE & CARBON MONOXIDE ALARM. DETECTORS SHALL BE CONNECTED TOGETHER WITH YELLOW WIRE AND ALL CONNECTED TO A COMMON DEDICATED CIRCUIT. DETECTORS SHALL BE PROVIDED WITH A BATTER BACKUP AND AUDIBLE ALARM. PROVIDE PROVISIONS TOLOCK-ON THE SMOKE DETECTOR CIRCUIT BREAKER. INTERCONNECTED SO THAT THE ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OTHER ALARMS IN THE DWELLING UNIT. 16.SINGLE OR MULTIPLE STATION SMOKE ALARM/CARBON MONOXIDE ALARMS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA, IN THE IMMEDIATE VICINITY OF BEDROOMS, IN EACH ROOM USED FOR SLEEPING PURPOSES,IN ENCLOSED COMMON STAIRWELLS OF APARTMENT COMPLEXES AND OTHER MULTIPLE-DWELLING COMPLEXES. 17.EXHAUST FANS LOCATED IN BATH AND SHOWER AREAS SHALL BE CONTROLLED BY A HUMIDISTAT. THE HUMIDISTAT SHALL BE ACCESSIBLE. 18.EXHAUST FANS FOR KITCHENS SHALL BE A MINIMUM OF 100 CFM. 19.LUMINARIES (LIGHT FIXTURES), LIGHTING OUTLETS, AND/OR CEILING FANS LOCATED OVER SPA OR HOT TUB OR WITHIN 5 FEET OF THE INSIDE WALLS OF THE SPA OR HOT TUB SHALL BE A MINIMUM OF 7'-6" ABOVE THE MAXIMUM WATER LEVEL AND SHALL BE PROTECTED BY A GROUND-FAULT CIRCUIT INTERRUPTER. LUMINARIES SHALL BE SUITABLE FOR DAMP. LOCATIONS PER CEC 2022. 20.RECEPTACLE OUTLET LOCATIONS WILL COMPLY WITH CEC ARTICLE 210.52 A.TAMPER RESISTANT RECEPTACLES FOR ALL LOCATIONS DESCRIBED IN 210.52 (I.E., ALL RECEPTACLES IN A DWELLING.) B.WEATHER RESISTANT TYPE FOR RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS (OUTSIDE) C.ARC-FAULT PROTECTION FOR ALL OUTLETS (NOT JUST RECEPTACLES) LOCATED IN ROOMS DESCRIBED IN NEC 210.12(A): KITCHENS, LAUNDRY AREAS, FAMILY, LIVING, BEDROOMS, DINING, HALLS, ETC. D.PROVIDE AT LEAST ONE 20A BRANCH CIRCUIT TO SERVE LAUNDRY OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. CEC210.11(C) (3) 21.ALL LIGHTING SHALL BE HIGH EFFICACY (FLUORESCENT, LED). LED LIGHTING SYSTEMS AND GU-24 LAMP HOLDER SHALL BE LISTED BY ENERGY COMMISSION AND SHALL MEET THE REQUIREMENTS OF TABLE 150-C. WATTS LUMENS/WATTS 5. AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE INSTALLED WITHIN 3 FEET OF THE EDGE AND ADJACENT TO EACH BASIN LOCATION AND SHALL BE GFCI PROTECTED. THE OUTLET SHALL BOT BE INSTALLED IN A FACE UP POSITION. 9. ALL FANS EXHAUST 3' FEET AWAY FROM AN EXTERIOR OPENING. 10. ALL LIGHTS OVER SHOWER OR BATHTUB ENCLOSED BY WALLS AND ENCLOSURES SHALL BE MARKED " SUITABLE FOR WET LOCATIONS". ALL LIGHTS OVER A BATHTUB WITH NO ENCLOSURE SHALL BE MARKED "SUITABLE FOR DAMP LOCATIONS". NO RECEPTACLES ARE PERMITTED IN A BATHTUB OR SHOWER SPACE. 11. NOT USED 12. CARBON MONOXIDE AND SMOKKE ALARMS ARE REQUIRED IN AREAS LEADING TO BEDROOMS AND ON EACH FLOOR LEVEL. 13. ALL KNOB TUBE WIRING THAT IS EXPOSED WHEN WALLS ARE OPENED IS TO BE REMOVED BACK TO THE ATTIC OR UNDER FLOOR ACCESSIBLE SPACES AND SPLICED IN A JUNCTION BOX WITH ROMEX, OR OTHER APPROVED WIRING METHOD, TO BE RUN BACK TO THE ORIGINAL LOCATION. KNOB TUBE BOXES MUST BE REPLACED TO ACCOMMODATE NEW WIRING TYPE. IF REMOVAL OR WIRING WOULD NECESSITATE OPENING OF ADDITIONAL WALLS NOT IN SCOPE, AND THE WIRING IS IN SOUND CONDITION, THEN IT MAY REMAIN. 5 OR LESS >5 TO 15 >15 TO 40 OVER 40 30 45 60 90 1.ALL PERMANENT LIGHTING IN BATHROOMS THAT ARE TO BE REMODELED SHALL BE HIGH EFFICACY (E.G. FLUORESCENT) OR SHALL BE CONTROLLED BY A MOTION SENSOR. 2.ALL LIGHT FIXTURES THAT ARE TO BE RECESSED INTO INSULATED CEILINGS (CAN LIGHTS) SHALL BE INSULATED CONTACTED (I.C.) RATED SO THAT INSULATION CAN BE PLACED OVER THEM. THE LIGHT FIXTURE HOUSING SHALL BE AIRTIGHT TO PREVENT CONDITIONED ARE ESCAPING INTO THE ATTIC OR CEILING CAVITY AND UNCONDITIONED ARE INFILTRATING FROM THE ATTIC OR CEILING CAVITY INTO THE CONDITIONED SPACE. 3.OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED FROM THE 20-AMP BRANCH CIRCUIT WHEN THE CIRCUIT SUPPLIES A SINGLE BATHROOM. 1.ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH ES TABLE 150.0-A. LIGHT SOURCES THAT ARE NOT MARKED "JA8-2016-E SHALL NOT BE INSTALLED IN ENCLOSED LUMINAIRES. ES 150.0(K) 2.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS AT LEAST ONE LUMINAIRE SHALL BE CONTROLLED BY A VACANCY SENSOR. 3.DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LED STYLE LUMINAIRES. TWO EXCEPTIONS: FIXUTRES INSTALLED IN HALLWAYS OR (CLOSETS UNDER 70 SF.) 4.RECESSED CAN LIGHT FIXTURES SHALL BE IC LISTED, AIR TIGHT LABELED, AND NOT BE EQUIPPED WITH A STANDARD MEDIUM BASE SCREW SHELL LAMP HOLDER. ES 150.0(K) 5.SFD OUTDOOR LIGHT FIXTURES THAT ARE ATTACHED TO A BUILDING ARE REQUIRED TO BE HIGH EFFICACY, BE MANUALLY ON/OFF SWITCH CONTROLLED, AND HAVE BOTH MOTION SENSOR AND PHOTOCELL CONTROL. SEE ES 150.0(K) 3 FOR ADDITIONAL CONTROL OPTIONS. 6.PROVIDE AT LEAST ONE 120V-20A BRANCH CIRCUIT TO SERVE BATHROOM RECEPTACLES. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. CEC210.11(C) (3) 7.PROVIDE AT LEAST ONE 20A BRANCH CIRCUIT TO SERVE LAUNDRY OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. CEC210.11(C) (3) 14.IF APPLICABLE: FOR A SINGLE-FAMILY DWELLING, THE SERVICE DISCONNECTING MEANS SHALL HAVE A RATING OF NOT LESS THAN 200 AMPERES WITH A SERVICE PANEL BUSS RATING OF A MINIMUM OF 225 AMPERES. THIS APPLIES TO BOTH NEW SFD’S AND ALL EXISTING SFD’S THAT ARE REPLACING THEIR ELECTRICAL SERVICES. 16. BATHROOM CIRCUITING SHALL BE EITHER: a)A 20-AMPERE CIRCUIT DEDICATED TO EACH BATHROOM, OR b)AT LEAST ONE 20 AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLE OUTLETS. PROJECT DATA SCOPE OF WORK REMOVE EXISTING 200 AMP PANEL ADD NEW 400 AMP PANEL PROPERTY OWNER: STEPHANIE MCCARTNEY AND DANIEL GRIFFITH 81180 LEGENDS WAY LA QUINTA, CA 92253 PROJECT ADDRESS 81180 LEGENDS WAY LA QUINTA, CA 92253 APN: 762-310-004 LEGAL DESCRIPTION: LOT 25 MB 285/51 TR 28838 PROJECT AREAS LOT SIZE: 15,6823 S.F. EXISTING LIVING AREA: 3,886.00 S.F. BUILDING DATA: ZONING: R OCCUPANCY TYPE: R3/U CONSTRUCTION TYPE: VB FIRE SPRINKLERS: NO YEAR BUILT: 1999 PROJECT IS APPROVED UNDER CITY OF LA QUINTA DEPARTMENT OF CODE COMPLIANCE: ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT BUSINESS LICENCE PRIOR TO PERMIT ISSUANCE PER MUNICIPAL CODE, TITLE 5. ALL CONTRACTORS AND/OR OWNER-BUILDERS MUST SUBMIT CERTIFICATE OF WORKER'S COMPENSATION INSURANCE COVERAGE PRIOR TO THE ISSUANCE OF A BUILDING PERMIT PER CALIFORNIA LABOR CODE, SECTION 1800. GENERAL CONTRACTORS AND/OR OWNER-BUILDERS SHALL COMPLETE AND SUBMIT A CONTRACTOR'S LIST FROM THE DEPARTMENT OF CODE COMPLIANCE PRIOR TO REQUEST FOR FINAL INSPECTION. DEPARTMENT OF BUILDING AND SAFETY : APPROVED TEMPORARY SANITARY FACILITIES ( I.E. CHEMICAL TOILETS) SHALL BE IN THE CONSTRUCTION SITE PRIOR TO REQUEST FOR FIRST INSPECTION ). HEALTH AND SAFETY CODE SECTION 5406. CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT OF WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES. 2019 CALIFORNIA BUILDING CODE CBC 2019 CALIFORNIA RESIDENTIAL CODE CRC 2019 CALIFORNIA MECHANICAL CODE CMC 2019 CALIFORNIA PLUMBING CODE CPC 2019 CALIFORNIA ELECTRICAL CODE CEC 2019 CALIFORNIA FIRE CODE CFC 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE CALGREEN 2019 CALIFORNIA ENERGY CODE CEC TITLE 24, PART 2, CALIFORNIA ADMINISTRATIVE CODE HANDICAP COMPLIANCE REGULATIONS AND ALL OTHER LOCAL CODES, ORDINANCES AND STATE AMENDMENTS. 11/15/2023Deisy Mendez 400A ELECTRICAL SERVICE CHANGE OUT [200A EXISTING] SURGE PROTECTION DEVICE REQUIRED PER CEC 230.67, A TYPE 1 OR 2 SPD SHALL BE INSTALLED PRIOR TO RELEASE BEING SENT TO UTILITY. THIS PERMIT DOES NOT INCLUDE RELOCATION OF EQUIPMENT OR ANY OTHER WORK. 2022 CALIFORNIA BUILDING CODES. BELC2023-1051 REMOVE EXISTING 200 AMP PANEL ELECTRICAL METER AND NEW 400 AMPS MAIN DISCONNECT AND MAIN PANEL WITH #3 REBAR UNDERGROUND WITH ACORN CLAMP CONNECTED TO COLD WATER PIPE E1.11 ELECTRICAL LAYOUT IS SCHEMATIC AND CAN BE RECONFIGURED BY GENERAL CONTRACTOR. ELECTRICAL PLAN 11/4" = 1'-0" SCALE ELECTRICAL PLAN ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E R EPRODUCED OR MODIFIED IN ANY WAY WITHOUT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY D OE S N OT R EL E ASE I N AN Y WAY THE COPY R IGHT AN D OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST SUBMITTAL 11/15/2023 220083 SHEET NAME DESIGNER OWNER STEPHANIE MCCARTNEY ADDRESS 81180 LEGENDS WAY LA QUINTA, CA 92253 PROJECT TYPE PANEL UPGRADE REVISIONS NO.DESCRIPTION DATE 75145 ST CHARLES PLACE #3 PALM DESERT, CA 92211 T: 760-219-3068 C: 760-219-3068 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M DANIEL GRIFFITH