BPOL2023-1056PERMIT SNAPSHOT REPORT BPOL2023-1056
FOR CITY OF LA QUINTA
Pool 10/24/2023App Date:Project:Permit Type
City of La QuintaPool Construction (Private)NOT AVAILABLEExp Date:District:Work Class:
0.00Approved with Conditions NOT COMPLETEDCompleted:Square Feet:Status:
Description:
Valuation:
POOL AND SPA,BBQ AND FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT
INCLUDE EQUIPMENT ENCLOSURE OR OUTDOOR SHOWER. TWO DROWNING PREVENTION SAFETY
FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION.
2022 CALIFORNIA BUILDING CODE.
$150,000.00 Assigned To:Approval
Expire Date:
Parcel:Main762310004 Address:81180 Legends Way
La Quinta, CA 92253
Main Zone:
Applicant
Enrique Zarate
40644 Carter Lane Bermuda
Dunes
Bermuda Dunes, CA 92203
Business: (760) 396-8936
Owner
FRANK CELEDON
Permit Custom Fields
Engineer of Record Pool Engineering Quantity of Detached
Spa(s)/Water
Feature(s)
0 BBQ Electrical (EA)11
Number of Gas
Outlet(s)
1 Mechanical Equipment
Relocation (QTY)
1 Garden Wall Linear
Foootage
136
Combination Retaining
Wall Linear Footage
0 Total Wall Length
(Linear Footage)
136 Zoning RL
General Plan LDR City Limits Within La Quinta Limits Subdivision Name TR 28838-1 AMENDED
Lot Number 25 Lot Size 2125.29 Centerlines 93586
Legal Description Lot 25 MB 285/51 TR
28838-1 AMENDED
Attachment File Name Added On Added By Attachment Group Notes
Signature_Enrique_Zarate_10/25/2023.j
pg
10/24/2023 18:59 Zarate, Enrique Uploaded via CSS
PLAN SET (APPROVED)_v1.pdf 11/03/2023 11:16 Mendez, Deisy Available Online Site Plan
Invoice No.Amount PaidFeeFee Amount
NOT INVOICED $0.00 Block Wall - Each Additional 50 LF $18.31
$0.00 Block Wall - First 100 LF $61.02
$0.00 Gas Piping System Outlets $15.26
$0.00 Swimming Pool / Spa PC $124.49
$0.00 Swimming Pool / Spa $228.84
$0.00 Receptacle, switch, lighting, or other outlets $30.51
$0.00 Condenser/Compressor $45.77
$0.00 Gas Piping System Outlets PC $30.51
$0.00 Building Standards Administration $6.00
$0.00 Condenser/Compressor PC $30.51
$0.00 Block Wall - First 100 LF PC $76.28
$0.00 Digital Archiving and Records Management Fee - OTC $12.00
$0.00 Technology Enhancement Fee $8.00
$0.00 Credit Card Convenience Fee $17.30
$0.00 Receptacle, switch, lighting, or other outlets PC $30.51
$735.31 $0.00 Total for Invoice NOT INVOICED
Page 1 of 278-495 Calle TampicoJanuary 09, 2024
PERMIT SNAPSHOT REPORT (BPOL2023-1056)
Grand Total for Permit $735.31 $0.00
Condition Description Date Created Satisfied
Contractor Information & Business
License
11/03/2023 NoContractor Information & Business License
Submittal Name Status Received Date Due Date Complete Date Resubmit Completed
ApprovedBuilding Review (1 Day) v.1 10/25/2023 11/01/2023 11/03/2023 No Yes
Completed
Date
Due
Date
Assigned
DateStatusAssigned UserDepartmentItem Review Name
Building (1 Day)Building Anaya, Julio Approved 10/25/2023 11/01/2023 11/03/2023
Comments: POOL AND SPA,BBQ AND FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE OR
OUTDOOR SHOWER. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
Completed
Date
Due
Date
Assigned
DateStatusAssigned UserDepartmentItem Review Name
Planning (1WK)Planning/Zoning Lima, Jack Not Required 10/25/2023 11/01/2023 10/26/2023
Comments: LANDSCAPE CHANGES
Workflow Step / Action Name Action Type Start Date End Date
Application Completeness Check v.1 10/25/2023 7:52 10/25/2023 7:52
Submittal Document Verification v.1 Generic Action 10/25/2023 7:52
Plan Check v.1 10/25/2023 0:00 11/03/2023 11:16
Building Review (1 Day) v.1 Receive Submittal 10/25/2023 0:00 11/03/2023 11:16
Permit Issuance v.1 11/03/2023 11:17
Verify Contractor info & Conditions have been met v.1 Generic Action 11/03/2023 11:17
Verify & Invoice Fees v.1 Generic Action
Verify Fee Payment & Issue Permit v.1 Generic Action
Print, Attach, and Email Building Permit v.1 Create Report
Pool Permit Inspection v.1
Pre-Gunite v.1 Inspection
Underground Plumbing v.1 Inspection
Underground Electrical v.1 Inspection
Underground Gas v.1 Inspection
Deck Bond v.1 Inspection
Pre-Plaster v.1 Inspection
Footing v.1 Inspection
Bond Beam v.1 Inspection
Inspections - Final v.1
Final Pool v.1 Inspection
Page 2 of 278-495 Calle TampicoJanuary 09, 2024
GAS
GASGAS
•
•
1.
2.
3.
4.
5.
•
1.
2.
3.
4.
5.
6.
•
NOTE:
EVERY PERSON WHO OWNS OR WHO IS IN POSSESSION OF LAND
UPON WHICH A SWIMMING POOL IS LOCATED SHALL CONSTRUCT AND
MAINTAIN IN GOOD CONITION COMPLETELY SURROUNDED SUCH
PARCEL OF LAND OR THE SWIMMING POOL ITSELF, AN ENCLOSURE
NOT LESS THAN FIVE FEET IN HEIGHT, CONSISTING OF A FENCE,
WALL., BUILDINGS, OR COMBINATION THEROF. (EXCEPTION; WITHIN A
WALLED, GATED COMMUNITY, WHEN THE SWIMMING POOL IS LOCATED
IN A REAR OR SIDE YARD THAT ABUTS A GOLF COURSE OR OTHER
COMMON OPEN SPACE
THE ENCLOSURE SHALL BE CONSTRUCTED OF SUBSTANBIAL
MATERIAL, AS ALLOWED ELSEWHERE IN LA QUNITA MUNICIPAL CODE,
AND SHALL HAVE ALL OF THE FOLLOWING CHARACTERISTICS.
ANY ACCESS GATES THROUGH THE ENCLOSURE OPEN AWAY
FROM THE SWIMMING POOL, AND ARE SELF-CLOSING WITH A
SELF-LATCHING DEVICE PLACED NO LOWER THAN 60 INCHES
(1524MM)
A MAXIMUM HEIGHT OF 60 INCHES (1524MM)
A MAXIMUM VERTICAL CLEARANCE FROM THE GROUNF TO THE
BOTTOM OF THE ENCLOSURE OF 2 INCHES (51MM)
GAPS OR VOIDS. IF ANY DO NOT ALLOW PASSAGE OF A SPHERE
EQUAL TO OR GREATER THAN 4 INCHES (102 MM) IN DIAMETER
AN OUTSIDE SURFACE FREE OF POTRUSIONS, CAVITIES OR
OTHER PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS
HANDHOLDS OR FOOTHOLDS THAT COULD ENABLE A CHILDE
BELOW THE AGE OF FIVE YEARS TO CLIMB OVER
FILTERING AND HEATING EQUIPMENT. USE OF EQUIPMENT SHALL
COMPLY WITH THE FOLLOWING REQUIREMENTS.
MECHANICAL POOL EQUIPMENT SUCH AS PUMP, FILTER, OR
HEATER, MAY BE LOCATED WITHIN THE FRONT OT REAR YARD
AREAS. THE EQUIPMENT SHALL BE ENCLOSED ON AT LEAST
THREE SIDES BY A MASONRY WALL WITH AN OPEN SIDE NOT
VISIBLE TO THE STREET.
MECHANICAL POOL EQUIPMENT MAY BE IN AN AREA BETWEEN
THE SIDE PROPERTY LINE AND THE RESIDENCE PROVIDED A 5
FOOT SETBACK, CLEAR OF ANY PERMANENT OBSTRUCTIONS IS
MAINTAINED BETWEEN THE SIDE YARD PROPERTY LINE AND ANY
MECHANICAL POOL EQUIPMENT.
WHERE THERE IS NO SIDE PROPERTY LINE WALL, MECHANICAL
POOL EQUIPMENT MAY BE IN A SIDE OF FIVE FEET OR LESS ONLY
IF A RECORDED EASEMENT IN PERPETUITY EXISTS FOR THE
SUBJECT PROPERTY TO USE THE ADJACENT SIDE YARD OF THE
ABUTTING PROEPRTY FOR ACCESS AND A MINIMUM FIVE FEET
DISTANCE BETWEEN THE EQUIPMENT AND ADJACENT
OBSTRUCTION (I.E. BUILDING WALL) IS PROVIDED.
MECHANICAL POOL EQUIPMENT MAY BE IN A SIDE OF FIVE FEET
IF APPROVED BY THE DESIGN AND DEVELOPMENT DIRECTOR IF
EXTENTUATING CIRCUMSTANCES EXIST AND THERE IS A THREE
FOOT CLEARANCE OF ANY PERMANENT OBSTRUCTIONS.
INSTALLATIONS OF POOL SYSTEMS AND EQUIPMENT WILL
COMPLY WITH SECTION 114-MANDATORY REQUIREMENTS
ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03
FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF
RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO
INSPECTION APPROVAL.
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO
ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART
680.26.
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA PLUMBING CODE. TITLE 24, PART 5
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS
OWNER RESPONSIBILITES
1.
2.
3.
4.
5.
DETERMINE THE APPROXIMATE ELEVATION OF POOL OR
SPA LAYOUT ON DAY OF EXCAVATION
TAKE NOTICE THAT POL AND EQUIPMENT LOCATIONS ARE
SUBJECT ACCEPTANCE OF LOCAL BUILDING DEPARTMENT
AT THE TIME OF ISSUANCE OF PERMIT
WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR
SEVEN DAYS AFTER SHELL IS INSTALLED.
SEE THAT ALL FENCING, GATESM AND GARAGE DOORS
MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO
PREPLASTER INSPECTION
FILL POOL IMMEDIATELY AFTER PLASTER. (FOLLOW
INSTRUCTIONS -- DO NOT USE RUBBER HOSE)
GENERAL NOTES
IF ANY DISCREPENCIES OR MEASUREMENTS ARE INCORRECT
THE CONTRACTOR MUST NOTIFY BLACK DIAMOND DRAFTING
& DESIGN OWNER. IF CONTRACTOR FAILS TO DO SO, BLACK
DIAMOND DRAFTING & DESIGN SHALL NOT BE RESPONSIBLE
FOR ANY CHANGES OR REVISIONS
D10
8190
-9"-18"
-36"-66"-36"
-9"WD
USUS-9"-18"-27"-36"-27"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"
3' - 5 3/4"71' - 6 29/32"14' - 0 15/16"
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/13/2023 3:58:11 PMCS
COVER SHEET
Project Number
GRIFFITH
RESIDENCE
Author
Checker
NEW OUTDOOR
PROJECT
81180 LEGENDS WAY, LA
QUINTA, CA, 92253
1/16" = 1'-0"1COVER SHEET
THE GRIFITH RESIDENCE
811180 LEGENDS WAY
PGA WEST C .C.
SHEET INDEX
CS - COVER SHEET
CS2 - COLORS AND MATERIALS
X1 - EXISTING / DEMO
C1 - CONSTRUCTION PLAN
C1.2 - CONSTRUCTION DETAILS
C1.3 - CONSTRUCTION DETAILS CONT'D
LS1 - LANDSCAPE PLANTING
L1 - LIGHTING PLAN
SCOPE OF WORK
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
1.
2.
3.
4.
5.
BACK YARD DEMO / CONSTRUCTION
DEMO POOL
DEMO SPA
DEMO HARDSCAPE
DEMO BBQ
DEMO PLANTS PER SHEET X-1
REPLACE POOL EQUIPMENT
BUILD NEW POOL AND SPA PER
PLAN
BUILD NEW FIRE PIT WITH BENCH
BUILD NEW PLANTER WITH
STORAGE
BUILD NEW BBQ AND BAR
REPAIR EXISTING WROUGHT IRON
GATE
INSTALL HARDSCAPE WIT TURF
STRIPS
INSTALL NEW LANDSCAPE AND
LIGHTING PER PLAN
BUILD TWO NEW OUTDOOR
SHOWERS
BUILD 2 NEW BLOCK WALLS WITH
GATE FOR PRIVACY FOR OUTDOOR
SHOWER ON NORTH SIDE
FRONT YARD
DEMO EXISTING DRIVEWAY AND
WALKWAY
REMOVE PLANTS PER SHEET X-1
REPLACE FRONT ENTRY
COURTYARD DOOR T.B.D.
ADD NEW LANDSCAPE AND
LIGHTING
BUILD 3+18" SQUARE PLANTER BLACK DIAMONDDRAFTING & DESIGN11/03/2023J.ANAYA
BPOL2023-1056
POOL AND SPA,BBQ AND FIRE PIT AT REAR YARD [POOL
ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT
ENCLOSURE OR OUTDOOR SHOWER. TWO DROWNING
PREVENTION SAFETY FEATURES AND THE REQUIRED
ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/13/2023 4:05:49 PMCS2
COLORS AND
MATERIALS
Project Number
GRIFFITH
RESIDENCE
Author
Checker
NEW OUTDOOR
PROJECT
81180 LEGENDS WAY, LA
QUINTA, CA, 92253
COLORS & MATERIALS
DIAMOND SCALE WATERLINE
96 DREAM OZ TURF
MAYRA LIMESTONE TILE FOR BENCHES /
RAISED BOND BEAM
MAYRA LIMESTONE COPING
MODERN EDGE
TUX WHITE 1"X2" SPA
SPILLWAY / TRIM TILE
ON BENCHES AND
STEPS
WHITE SMOOTH STUCCO ON BAR/ BACK
OF RAISED BOND BEAM
IPE WOOD ON BBQ ONLY
KICHLER
PATH LIGHT
KICHLER
UP LIGHT
BLAZE PIZZA OVEN
PALM SHADE CAESERSTONE ON COUNTER TOP
HISENSE MINI FRIDGE
MODEL#HBC54D6AS
ICE DROP IN LION
BRAND MODEL #
2853074
POOL MATERIALS
HARDSCAPE
LIGHTING
BBQ / BAR / FIRE PIT AND BENCH FINISHES
BBQ / BAR INSERTS
BLAZE 50 LB 15" WIDE
OUTDOOR RATED ICE
MAKER (BLZ-
ICEMKR-50GR)
EVO AFFINITY 30G BUILT
INGRILL (HOMEOWNER
PURCHASED)
DCS 36" NATURAL GAS
W/ ROTISSEIRE
(BE1-36RC-N)
DCS 36"
DOUBLE DOOR
ACCES
(ADM1-20X36)
ONE FOR BAR /
ONE FOR
UNDER BBQ
DCS 20" R0LL OUT
TRASH BIN (TB1-20)
KUZCO
LIGHTING
EW71412-GY
ANGELUS 4"X12" SAND
COPPER STONE PAVER BLACK DIAMONDDRAFTING & DESIGNAQUAWHITE MINI PEBBLE
24"X24" PORCELAIN PAVER
OUTDOOR WALL
SCONCE
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/13/2023 4:06:43 PMX1
EXISTING / DEMO
PLAN
Project Number
GRIFFITH
RESIDENCE
Author
Checker
EXISTING PLAN
81180 LEGENDS WAY, LA
QUINTA, CA, 92253
EXISTING LANDSACPE IN BOXED
REGION TO REMAIN
EXISTING PALM TREE TO BE REMOVED
EXISTING PALM TREE
TO BE REMAIN
EXISTING PALM TREE
TO REMAIN
EXISTING BBQ TO BE REMOVED.
EXISTING GAS RISER AND ELECTRICAL
LINES TO REMAIN
EXISTING
DRIVEWAY
AND
WALKWAY TO
BE REMOVED
EXISTING POOL EQUIPMEN TO BRE
REPLACED. PLEASE REFER TO SHEET C-1
EXISTING WROUGHT IRON
GATE SELF CLOSING -
SELF LATCHING TO
REMAIN
EXISTING FRONT
GATE TO BE
REPLACED
EXISTING GATE TO BE REPAIRED.
PLEASE REFER TO SHEET C1TRUE BLACK DIAMONDDRAFTING & DESIGND10
8190
EXISTING PALM TREES REMOVAL TO BE DETERMINED UPON POOL CONSTRUCTION
1/8" = 1'-0"1Site
MEDITERAANEAN FAN PALM AND BUSHES
TO BE REMOVED
BUSHES, BOULDER AND
MEDITERANEAN FAN PALM TO BE
REMOVED
MEDITERNANEAN FAN PALM AND
BUSHES TO BE REMOVED
BOULDER, BUSHES AND MEDITERANEAN
FAN PALM TO BE REMOVED
NOTE: ALL SYMBOLS IN RED SHALL BE REMOVED /
DEMOED
BBQ
POOL & SPA
HARDSCAPE
EXISTING HARDSCAPE , POOL AND SPA
TO BE REMOVED / DEMOED
D10
8190
42' - 0"21' - 0"9' - 0"10' - 0"14' - 0"13' - 0"13' - 0"3' - 0"-9"-18"
-36"-66"-36"
-9"WD
USUS-9"-18"-27"-36"
12' - 6"12' - 6"3' - 0"6' - 6"10' - 0"4' - 0"-27"12' - 0"13' - 0"13' - 0"
3' - 0"
EXISTING
A/C UNITS
TO REMAIN
96 OZ GOLD
STANDARD
TURF
PORCELAIN PAVER
WHITE R11 MATTE
24X48
BLACK MEXICAN
BEACH PEBBLE
ORCO PAVER
MANOR GRAY
PLANK
49' - 6"
3' - 5"
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:7/16/2023 5:16:54 PMC-1
CONSTRUCTION
PLAN
Project Number
THE GRIFITH
RESIDENCE
Author
Checker
STEPHANIE & DAN
GRIFITH
81180 LEGENDS WAY, LA
QUINTA, CA, 92253
1/8" = 1'-0"1POOL PLAN
1
2
3
4
56
7
89
ITEMIZED LEGEND
CALLOUT # DESCRIPTION
1 (3) NEW 12'-6" X 12'-6" +18" HEIGHT PLANTER TO BE BUILT OUT OF 8"X8"X16"
PRECISION BLOCK
2 EXISTING DRIVEWAY / FRONT WALKWAY TO BE REMOVED. 1600 SQFT OF NEW
AQUALINA ORCO PAVERS IN MANOR COLOR TO BE INSTALLED. 4" OF CLASS - 2 ROAD
BASE TO BE COMPACTED @95%. 2" MINIMUM OF BEDDING SAND TO BE HAND
TROWELED WITH PROPER PITCH AWAY FROM DWELLING.
3 NEW OUT DOOR SHOWER HARDSCAPE TO MATCH POOL DECK. NEW DRAIN 3" ROUND
DRAIN TO BE INSTALLED. NEW SHOWER SYSTEM TO BE INSTALLED PLEASE REFER TO
ARCHITECTURAL PLANS PER "MDESIGN GROUP, INC."
4 ALL NEW JANDY POOL EQUIPMENT TO BE INSTALLED. (1) JANDY CV CARTRIDGE
FILTER CV 580. (1) JANDY VERSA TEMP HEAT/CHILL PUMP. (2) VS FLOPRO 2.7 HP DV2A
PUMPS (1) AQUA LINK RS POOL/SPA AUTOMATION SYSTEM WITH 36" CLEARANCE
MINIMUM. POOL EQUIPMENT TO BE SEISMICALLY ANCHORED
5 NEW CMU FREE STANDING BBQ WITH (1) 32" GRILL (1) 32" DRAWER DOOR COMBO (1)
24" WIDE HISENSE UNDER COUNTER FRIDGE (1) EVO GRIDDLE (1) PIZZA OVEN WITH
32" WIDE ACCESS DOORS. (2) EXTERIOR GFCI WEATHER PROOF OUTLETS (3) GFCI
UNDERCOUNTER WEATHER PROOF OUTLETS
6 NEW CMU FREE STANDING BAR. (4) TOTAL INSERTS .(1) ICE MAKER (1) PULL OUT
TRASH CAN (1) ICE BUCKET DROP IN (1) DOUBLE ACCESS DOORS
7 NEW SUNKEN ATRIUM WITH NEW 3'-0" X 6'-6" +18" HEIGHT FIRE PIT TO BE BUILT OUT
OF 6"X8"X16" BLOCK. 1" POLYETHYLENE GAS LINE TO BE RAN FROM GAS METER AND
WRAPPED WITH YELLOW TRACER WIRE. NEW BENCHES TO BE BUILT OUT OF
8"X8"X16" PRECISION BLOCK.
8 NEW (21'-0" X 42'-0" +0") POOL/SPA/TANNING SHELF TO BE BUILT OUT OF SHOTCRETE.
AQUA BLUE MINI PEBBLE TO BE INSTALLED. WHITE DIAMOND SCALE WATERLINE TILE
TO BE INSTALLED AROUND POOL AND SPA WATERLINE. WHITE TUX 1"X2" TRIM TILE
ON ALL STEP / BENCHES EDGES AND SPA INFINITY LIP. (2) BUBBLERS AS RETURN
NON L.E.D. WITH (2) UMBRELLA SLEEVES.
9 900 SQUARE FEET OF 96 OZ GOLD STANDARD TURF TO BE INSTALLED.
10 1800 SQFT OF NEW WHITE R11 MATTE 24"x48" CROSSOVER WHITE R11 MATTE 24"X48"
PORCELAIN PAVER TO BE INSTALLED IN 4'-0" X 10'-0" PADS WITH TURF STRIPS.
11 OUT DOOR SHOWER TO BE INSTALLED. PLEASE REFER TO ARCHITECTURAL PLANS
PER "MDESIGN GROUP, INC"
12 (2) NEW PRIVACY 5' HEIGHT BLOCK WALLS TO BE BUILT OUT OF 6"X8"X16" CMU
PRECISION BLOCK TO BE COVERED IN WHITE SMOOTH STUCCO. NEW 3'-6"
WIDEWROUGHT IRON GATE TO BE INSTALLED
13 NEW +30" HEIGHT RAISED PLANTER BOND BEAM WITH (3) SHEER DESCENTS EACH AT
8' WIDE TO BE EVENLY SPACED OUT. INSIDE OF PLANTER TO BE WATERPROOFED.
RAISED PLANTER TO BE BUILT OUT OF 6"X8"X16" CMU PRECISION BLOCK
14 PRE FABRICATED COLD PLUNGE TO BE PURCHASED BY HOMEOWNER AND
INSTALLED BY CONTRACTOR. BLACK EMXIACAN BEACH PEBBLE TO BE PLACED
AROUND HARDSCAPE AS INDICATED ON PLAN.
10
11
12
EXISTING GAS METER
EXISTING ELECTRICAL METER
13
PROPERTY LINE TRUE14
HATCH LEGEND
MATERIAL QUANTITY
WATERLINE TILE 166 LFWHITE DIAMOND SCALE
TRIM TILE WHITE TUX N.P.T. WHITE GROUT 100'LF @ 1"
COPING PORCELAIN PAVER MODERN
EDGE COPING
120' LF
BUBBLER 2RETURN LINE BUBBLER
UMBRELLA SLEEVE TANNING SHELF 2
SPA LIGHT JANDY L.E.D. MINI 1
POOL LIGHTS JANDY L.E.D. LARGE 4
BBQ / BAR/ BOND
BEAM CAP
PALM SHADE CAESER STONE ~200 SQFT
BACK YARD PAVING PORCELAIN PAVER 24X48
WHITE R11 MATTE
1800 SQFT
GOLD STD 96 OZ TURFTURF 900 SQFT
DRIVEWAY / WALKWAY ORCO GRAY MANOR PLANK 1600 SQFT BLACK DIAMONDDRAFTING & DESIGNDigitally signed by Matthew Thompson on 09/27/2023 - 1695798000 - 23-08466-dg
100
NOT PART OF
SCOPE OF WORK,
WORK BY OTHERS
11/03/2023J.ANAYA
BPOL2023-1056
POOL AND SPA,BBQ AND FIRE PIT AT REAR YARD [POOL ENGINEERING]
THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE OR
OUTDOOR SHOWER. TWO DROWNING PREVENTION SAFETY FEATURES
AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
Digitally signed by Matthew Thompson on 09/27/2023 - 1695798000 - 23-08466-dg
GAS
GASGAS
D10
8190
19' - 1"9' - 0"10' - 0"14' - 0"13' - 0"13' - 0"-9"-18"
-36"-66"-36"
-9"WD
USUS-9"-18"-27"-36"-27"13' - 0"3' - 0"
EXISTING
A/C UNITS
TO REMAIN
96 OZ "DREAM"
TURF
PORCELAIN PAVER
SAND SQUARE 24"X24"
BLACK MEXICAN BEACH
PEBBLE
ANGELUS 4"X12" SAND
COPPER STONE
4' - 4"
3' - 0"
30' TOTAL FEET OF NEW
GAS LINE TO BE TAPPED
IN FROM EXISTING BBQ
GAS. 1" POLYETHYLENE
GAS LINE TO BE RAN TO
NEW FIR EPIT LOCATION.
GAS LINE TO BE WRAPPED
IN YELLOW TRACER WIRE.
GAS LINE SHALL BE DUG
18" BELOW FINISHED
GRADE MINIMUM
15' - 5"
26' - 0"15' - 2"8' - 2"13' - 0"5' - 1"
14' - 6"
40' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"
3' - 6"71' - 7"14' - 1"60' - 4"9' - 1"12' - 0"5' - 0"6' - 6"3' - 0"2' - 7"2' - 7"1' - 11"2' - 0"8' - 6"9' - 0"2
C-38' - 5"8' - 1"0' - 6"
49' - 0"7' - 0"
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/24/2023 2:44:19 PMC-1
CONSTRUCTION
PLAN
Project Number
THE GRIFFITH
RESIDENCE
Author
Checker
STEPHANIE & DAN
GRIFFITH
81180 LEGENDS WAY, LA
QUINTA, CA, 92253
1/8" = 1'-0"1PLAN VIEW
1
2
3
4
56
7
89
ITEMIZED LEGEND
CALLOUT
#
DESCRIPTION
1 (3) NEW 12'-6" X 12'-6" +18" HEIGHT PLANTER TO BE BUILT OUT OF 8"X8"X16"
PRECISION BLOCK
2 EXISTING DRIVEWAY / FRONT WALKWAY TO BE REMOVED. 1600 SQFT OF NEW
AQUALINA ORCO PAVERS IN MANOR COLOR TO BE INSTALLED. 4" OF CLASS - 2
ROAD BASE TO BE COMPACTED @95%. 2" MINIMUM OF BEDDING SAND TO BE HAND
TROWELED WITH PROPER PITCH AWAY FROM DWELLING.
3 NEW OUT DOOR SHOWER HARDSCAPE TO MATCH POOL DECK. NEW DRAIN 3" ROUND
DRAIN TO BE INSTALLED. NEW SHOWER SYSTEM TO BE INSTALLED PLEASE REFER
TO ARCHITECTURAL PLANS PER "MDESIGN GROUP, INC."
4 ALL NEW JANDY POOL EQUIPMENT TO BE INSTALLED. (1) JANDY CV CARTRIDGE
FILTER CV 580. (1) JANDY VERSA TEMP HEAT/CHILL PUMP. (2) VS FLOPRO 2.7 HP
DV2A PUMPS (1) AQUA LINK RS POOL/SPA AUTOMATION SYSTEM WITH 36"
CLEARANCE MINIMUM. POOL EQUIPMENT TO BE SEISMICALLY ANCHORED
5 NEW CMU FREE STANDING BBQ WITH (1) 32" GRILL (1) 32" DRAWER DOOR COMBO (1)
24" WIDE HISENSE UNDER COUNTER FRIDGE (1) EVO GRIDDLE (1) PIZZA OVEN WITH
32" WIDE ACCESS DOORS. (2) EXTERIOR GFCI WEATHER PROOF OUTLETS (3) GFCI
UNDERCOUNTER WEATHER PROOF OUTLETS
6 NEW CMU FREE STANDING BAR. (4) TOTAL INSERTS .(1) ICE MAKER (1) PULL OUT
TRASH CAN (1) ICE BUCKET DROP IN (1) DOUBLE ACCESS DOORS
7 NEW 3'-0" X 6'-6" +18" HEIGHT FIRE PIT TO BE BUILT OUT OF 6"X8"X16" BLOCK. 1"
POLYETHYLENE GAS LINE TO BE RAN FROM GAS METER AND WRAPPED WITH YELLOW
TRACER WIRE. NEW BENCHES TO BE BUILT OUT OF 8"X8"X16" PRECISION BLOCK.
8 NEW (21'-0" X 42'-0" +0") POOL/SPA/TANNING SHELF TO BE BUILT OUT OF
SHOTCRETE. AQUA BLUE MINI PEBBLE TO BE INSTALLED. WHITE DIAMOND SCALE
WATERLINE TILE TO BE INSTALLED AROUND POOL AND SPA WATERLINE. WHITE TUX
1"X2" TRIM TILE ON ALL STEP / BENCHES EDGES AND SPA INFINITY LIP. (2)
BUBBLERS AS RETURN NON L.E.D. WITH (2) UMBRELLA SLEEVES.
9 900 SQUARE FEET OF 96 OZ GOLD STANDARD TURF TO BE INSTALLED.
10 1800 SQFT OF NEW WHITE R11 MATTE 24"x48" CROSSOVER WHITE R11 MATTE
24"X48" PORCELAIN PAVER TO BE INSTALLED IN 4'-0" X 10'-0" PADS WITH TURF
STRIPS.
11 OUT DOOR SHOWER TO BE INSTALLED. PLEASE REFER TO ARCHITECTURAL PLANS
PER "MDESIGN GROUP, INC"
12 (2) NEW PRIVACY 5' HEIGHT 16'-6" TOTAL LINEAR FEET BLOCK WALLS TO BE BUILT
OUT OF 6"X8"X16" CMU PRECISION BLOCK TO BE COVERED IN WHITE SMOOTH
STUCCO. NEW 3'-6" WIDEWROUGHT IRON GATE TO BE INSTALLED
13 NEW +16" HEIGHT RAISED BOND BEAM WITH (3) SHEER DESCENTS EACH AT 8' WIDE
TO BE EVENLY SPACED OUT. RAISED BONDBEAM TO BE BUILT WITH RAISED
SHOTCRETE/ GUNNITE WALL PER POOL ENGINEERING
14 PRE FABRICATED COLD PLUNGE TO BE PURCHASED BY HOMEOWNER AND
INSTALLED BY CONTRACTOR. BLACK EMXIACAN BEACH PEBBLE TO BE PLACED
AROUND HARDSCAPE AS INDICATED ON PLAN.
15 NEW RAISED PLANTER BUILT OUT OF CMU PRECISION BLOCK WITH STORAGE
UNDERNEATH IT. PLEASE REFER TO DETAILS ON C-3
16 NEW WROUGHT IRON GATE PAINTED BLACK WITH SELF LATCHING - SELF CLOSING
GATE TO BE INSTALLED @ 4' HEIGHT
10
11
12
EXISTING GAS METER
EXISTING ELECTRICAL METER
13
PROPERTY LINE TRUE14
HATCH LEGEND
MATERIAL QUANTITY
WATERLINE TILE 166 LFWHITE DIAMOND SCALE
TRIM TILE WHITE TUX N.P.T. WHITE GROUT 100'LF @ 1"
COPING MAYRA WHITE 5CM MODERN EDGE 120' LF
BUBBLER 2RETURN LINE BUBBLER
UMBRELLA SLEEVE TANNING SHELF 2
SPA LIGHT JANDY L.E.D. MINI 1
POOL LIGHTS JANDY L.E.D. LARGE 4
BBQ / BAR / FIREPIT PALM SHADE CAESER STONE ~200 SQFT
BACK YARD PAVING PORCELAIN PAVER SAND SQUARE
24"X24"
1800 SQFT
GOLD STD 96 OZ TURFTURF 900 SQFT
DRIVEWAY / WALKWAY ANGELUS 4"X12" SAND
COPPER STONE PAVER
1900 SQFT BLACK DIAMONDDRAFTING & DESIGNEXISTING WROUGHT
IRON TO BE
REPARIED
EXISTING SELF
LATCHING / SELF
CLOSING GATE TO
REMAIN
FRONT ENTRY
DOORS TO BE
REPLACED.
DOORS SPECS
T.B.D.
15
16
F.G.
0' - 0"
FOOTING-1' - 4"
TOP OF BBQ3' - 0"
1' - 3"3' - 0"0' - 6"2' - 0"0' - 6"2' - 7"0' - 8"2' - 0"0' - 6"1' - 4"EVO AFFINITY 30G BUILT IN
FLATTOP NATURAL GAS
(10-0055-NG)
26" BUILT IN NATURAL GAS
OUTDOOR PIZZA OVEN
(BLZ-26-PZOVN-NG
GFCI WEATHER PROOF OUTLETS
"IPE WOOD" VERTICAL
SLATS TO BE
INSTALLED
F.G.0' - 0"
FOOTING-1' - 4"
TOP OF BAR
3' - 0"
TOWEL/STORAGE AREA ON BAR
PALM SHADE CASERSTONE TO GO ON CAP
13' - 4"3' - 0"2' - 7"0' - 6"GFCIWPGFCIWPGFCIWP13' - 0"
0' - 9"3' - 0"4' - 4"10' - 4"1' - 2"2' - 2"
13' - 0"0' - 2"3' - 1"GFCI
WP
GFCI
WP
GFCI
WP
GFCIWPGFCIWP1' - 0"
NEW POOL WALL
#4 REBAR @18" O.C.1' - 6"#4 REBAR CONTIUOUS
#4 REBAR @ 18" O.C. GROUT FILL CELLS CONTAINING REBAR
6"X8"X16" CONC. BLOCK AND STUCCO FINISH TO
MATCH RESIDENCE
#4 REBAR CONTINUOUS
CONCRETE FOOTING PER CITY
STANDARDS 3250 PSI
BEND ALTERNATIVELY FROM SIDE TO SIDE
95% COMPACY SUBGRADE
FINISHED GRADE
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/24/2023 3:00:12 PMC1.2
CONSTRUCTION
DETAILS
Project Number
GRIFITH
RESIDENCE
Author
Checker
CONSTRUCTION
81180 LEGENDS WAY
1/2" = 1'-0"1Section 1
1/2" = 1'-0"2BAR ELEVATION
1/2" = 1'-0"3BBQ PLAN
1/2" = 1'-0"4BAR PLAN
36" DCS SERIES 9 NATURAL GAS
GRILL WITH ROTISSERIE
(BE1-36RC-N) WITH DCS 36"
DOUBLE ACCESS DOOR (ADN1-
20X36)
HISENSE 24" WIDE
STAINLESS STEEL BUILT
IN WITH GLASS DOOR
DCS 36" DOUBLE ACCESS DOOR
(ADN1- 20X36)
BLAZE 50 LBS 15" OUTDOOR RATED
ICE MAKER (BLZ-ICEMKR-50GR)
LION SATINLESS STEEL DROP IN BIN
WITH CONDIMENT TRAY (2853074)
GFCI WEATHER RATED OUTLETS
2500 PSI 16" DEEP FOOTING
#4 REBAR CONTINOUS
6"X8"X16" CMU BLOCK,
GROUT, FILL ALL CELLS
MAYRA WHITE LIMESTONE
NOSE BAR
COLOR CHANGING
L.E.D.
EXPANSION JOINT
HARDSCAPE T.B.D.90% COMPACTED SUBGRADE
6
4" LAVA ROCK
GAS GRATE WITH FIRE ROCK
PALM SHADE CAESERSTONE TO WRAP AROUND FIRE PIT
#4 REBAR @ 18" O.C.
6"X8"X16" CMU BLOCK
#4 REBAR CONTINOUS
PORCELAIN PAVER R11
CROSS OVER REFER
TO SHEET C1 FOR
FURTHER DETAIL
CONCRETE FOOTING, 3250 PSI
95% COMPACTED SUBGRADE3/4" DIA GRAVEL
1" GAS LINE
1/2" = 1'-0"5FIRE-PIT SECTION
NOTCH FOR L.E.D.
STRIP UNDER FIRE PIT BLACK DIAMONDDRAFTING & DESIGN 1/2" = 1'-0"7 RAISED PLANTER W/ SHEER DESCENT
BOTTOM INLET SHEER DESCENT
SHEER DESCENT SUPPLY LINE
#4 REBAR CONTINOUS
WATER LINE
DIAMOND SCALE
WATERLINE TILE
PER SHEET C1
1/2" = 1'-0"8BLOCK WALL
4' - 0"9' - 5"
8' - 6"1' - 0"#5 REBAR SPACED AT EVERY 8" HORINTALLY
WITH TIES ON EACH INTERSECTION.
CONCRETE SLAB TO BE POURED @3250 PSI
SUPERBLOCKADE CEMENTIOUS
WATERPROOFING MEMBRANE TO BE
HAND TROWLED. 2 COATS MINIMUM
6"X8"X16" ANGLEUS CMU PRECISION BLOCK
#5 VERTICAL REBAR
#4 HORIZONTAL REBAR
#4 HORIZONTAL REBAR SPACED AT EVERY 1'
CONCRETE FOOTING TO BE POURED AT 3250 PSI2' - 10"1' - 2"2' - 7"9' - 0"
#5 VERTICAL REBAR WITH TIES
#4 HORIZONTAL REBARS
TO LAP AROUND
PERIMETER OF
STRUCTURE. TIES AT
EACH INTERSECTION
#5 REBAR SPACED AT EVERY 8" HORINTALLY
WITH TIES ON EACH INTERSECTION.
0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 2"3' - 11"0' - 8"0' - 10"0' - 8"
3' - 0"
BLACK PAINT COATED WROUGHT
IRON FENCE TO BE INSTALLED
PER LINE ITEM #16
BLACK PAINT COATED WROUGHT IRON GATE WITH
HINGES TO BE SELF LATCHING / SELF CLOSING
8"X10"
FOOTING FOR
FENCE POST
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/16/2023 7:30:24 PMC-3
CONSTRUCTION
DETAILS
Project Number
THE GRIFFITH
RESIDENCE
Author
Checker
STEPHANIE & DAN
GRIFFITH
81180 LEGENDS WAY, LA
QUINTA, CA, 92253
1/2" = 1'-0"1RAISED PLANTER / STORAGE
1" = 1'-0"2WROUGHT IRON FENCE / GATE BLACK DIAMONDDRAFTING & DESIGN
D10
8190
-9"-18"
-36"-66"-36"
-9"WD
USUS-9"-18"-27"-36"
12' - 6"12' - 6"-27"EXISTING
PUTTING
GREEN TO
REMAIN
NO
LANDSCAPE/LIGHTING
TO BE ALTERED IN
THIS AREA
EXISTING SOD
TO REMAIN
EXISTING SOD
TO REMAIN
LANDSCAPE LEGEND
phoneix dactylifera
/ date palm
SYMBOL COMMON NAME QTY
asparagus 'meyeri"15
nerium oleandor /
petite salmon
mexican bush sage 26
dianella tasmanica / falx lilly 18
34
strelitza reginae/
bird of paradise
19
2
GALLON
15
10 6
10
39
13
15
caesalpina pulcherrima/
red bird of paradise
15/25 3
129
PINK BOUGAINVILLEA 605' HEIGHT
10' HEIGHT
•
•
•
•
•
•
•
ALL PLANTS. TREES/ SHRUBS SHALL BE LOCALLY GROWN
AND PURCHASED.
THESE PLANTS ARE CALLED OUT FROM LOCAL MOON
NURSERY
CONTRACTOR TO COORDINATE APPROVAL. CONTRACTOR
SHALL REMOVE ALL GROWER STAKES, TAGS AND
RIBBONS.
CONTRACTOR TO MAINTAIN PROPER DRAINAGE AND
DIRECT ALL WATER AS TO PREVENT STANDING WATER
NO PLANTS SHALL BE PLANTED THAT WILL CREATE A
VISUAL OBRSTUCTION OF SIGHT LINE VEHICLE TRAFIC
ALL PLANTING SHALL BE VERIFIED AND APPROVED FROM
HOMEOWNER WITH CONTRACTOR.
ALL PLANTING AREAS EXCEPT LAWNS SHALL BE
COVERED WITH MINIMUM 3" OF ORGANIC MULCH UNLESS
NOTED
ALL LANDSCAPE SHALL HAVE THESE REQUIRED SETBACKS
PER PGA WEST HOA REQUIREMENTS AND GUIDELINES PER
PLANT PALLETE
LANDSCAPE NOTESTRUElavendula stoechas
/ spanish lavender
lirope muscari / majestic
LEMON COVE 1-2" ON ALL
PLANTER BEDS
LEMON COVE 1-2" ON ALL
PLANTER BEDSLEMON COVE 1-2" ON ALL
PLANTER BEDS
EXISTING CALIFORNIA PALM TREES TO
REMAIN
ASPARGUS 'MEYERI'
DIANELLA TASMANICA 'FLAX LILLY'
LAVANDULA STOECHAS 'SPANISH LAVENDER'
LIROPE MUSCARI 'MAJESTIC'
NERIUM OLEANDER DWARD 'PINK LADY/ PETITE
SALMON'
STRLITZA REGINAE 'BIRD OF PARADISE'
BOUGAINVILLEA 'RASBERRY ICE, ROSENKA TORCH
GLOW'
MINIMUM SPACING REQUIREMENT
4'-6' MINIMUM
4' MINIMUM
3'-4' MINIMUM
1'-2' MINIMUM
3' MINIMUM
2'-3' MINIMUM
3' MINIMUM
EXISTING TREE AND
SAGO PALM TO
REMAIN
2' - 6"2' - 7"existing palms to remain
7' - 8"5' - 1"9' - 7"BLACK DIAMONDDRAFTING & DESIGNPROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/16/2023 7:24:21 PMLS1
PLANTING PLAN
GRIFFITH
RESIDENCE
Author
Checker
LANDSCAPE
81180 LEGENDS WAY, LA
QUINTA, CA, 92253
1/8" = 1'-0"1PLANTING PLAN Copy 1
3 TYP. PATHLIGHT
1
2
3
5
LOW VOLTAGE LIGHT FIXTURE-SEE
LEGEND
1
3 COMPACTED SOIL
SPIKE MOUNT-SEE MFG. SPECTS
LANDSCAPE TOP SURFACE MATERIAL,
FINISH SURFACE -SEE
PLANTING PLAN
*SPIKE MOUNT TO NOT BE EXPOSE ,
BARIED
BELOW TOP SURFACE MATERIAL
4
2
5 VARIES4
LOW VOLTAGE CABLE-SEE MFG. SPECS
*LEAVE 18" MIN. WIRE LOOP
COILED BELOW FIXTURE FOR
SERVICE.
NTS
2 TYP. UP LIGHT
1
2
4
3
5
1 LIGHT FIXTURE - SEE LEDGEND
2 FINISH GRADE (F.G.)
3 COMPACTED SOIL
LOW VOLTAGE CABLE-SEE MFG. SPECS
*LEAVE 18" MIN. WIRE LOOP
COILED BELOW FIXTURE FOR
SERVICE.
4
5 SPIKE MOUNT-SEE MFG. SPECTS
NTS
1 TYP. TRANSFORMER
1
2
2
3
4 4
VARIES1
5
LOW VOLTAGE TRANFORMER - SEE
LEDGEND
1
WP-GFI ELECTRICAL OUTLET W/ COVER
*CONTRACTRO TO OBTAIN PERMIT
2
MOUNTING SURFACE
*CONTRACTOR TO VERIFY LOCATION W/
OWNER PRIOT
TO CONSTRUCTION
3
LENGTH OF WIRE AND JUNCTION BOX TO
BE DETERMINED.
*ELECTRICAL PER CONTRACTOR
4
5 FS - SEE HARDSCAPE PLA
FRONT VIEW SIDE VIEW
NTS
D10
8190
-9"-18"
-9"WD
USUS-9"-18"-27"-36"-27"EXISTING
A/C UNITS
TO REMAIN
300 WATT
TRANSFORMER
300 WATT
TRANSFORMER
KICHLER LOW VOLTAGE SPOT LIGHT
KICHLER LOW VOLTAGE PATH LIGHT
LIGHTING LEGEND
SYMBOL NAME QTY
KUZCI LIGHTING CASA
12" WIDE LED OUTDOR
WALL SCONCE
12
KICHLER LOW VOLTAGE
2.4 WATT SPOT LIGHT
KICHLER LOW VOLTAGE
2.4 WATT PATH LIGHT
19
37
MILLENNIUM LIGHITNG
BARKELEY 22" TALL
OUTDOOR WALL
SCONCE IN POWDER
COAT BLACK
REPLACEABLE BULB
5
PROJECT NO:
DRAWN BY:
CHECKED BY:
OWNER:
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT MANAGER:CONSULTANT:10/16/2023 7:25:07 PML-1
LANDSCAPE
LIGHTING
Project Number
GRIFITH
RESIDENCE
Author
Checker
LIGHTING
81180LEGENDS WAY, LA
QUINTA, CA, 92253
1/8" = 1'-0"1Level 1 Copy 1 BLACK DIAMONDDRAFTING & DESIGN