BELC2023-1012DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Electrical
Permit Number:
BELC2023-1012
Property Address:
48704 VISTA PALOMINO
APN:
602200021
Legal Description
Lot 61 MB 289/77 TR 29306
Property Zoning:
RL, 61
Valuation:
$1,949.00
BUILDING PERMIT
PHONE (760) 777-7125
�� WWW.LAQUINTACA.GOV
APPLIED DATE: 09/07/2023
eca QISSUED DATE: 09/11/2023
CALIFORNIA
Owner: Robert & Susan Anderson
Applicant: Sherryl Hegge
83852 Avenue 45, Indio, CA 92201
Contractor: Isabel Torres / 748171
83852 AVE 45, INDIO, CA 92201
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 1/20/24 12:04 am Page 1 of 3
1-31111111]1Z"a4 N IT, IkI
Permit Type: Electrical
Permit Number: BELC2023-1012
Property Address: 48704 VISTA PALOMINO
INSTALL (1) 240V 40AMP DEDICATED CIRCUIT AT GARAGE FOR VEHICLE CHARGING. 2022 CALIFORNIA BUILDING CODES.
instruction net;.
New Electrical Square 0 Number of 1 Number of Residential 0
Footage Receptacle/Switch/Lig Appliances
ht(s)
Number of 0 Number of Power 0 Number of Signs 0
Non -Residential Apparatus
Appliances
Fee Amount
Amount Paid
INV -00000506 Credit Card Convenience Fee
Electrical Service?
No
Temporary Power
No
Miscellaneous 0
$110.88
$110.88
Service?
Electrical
Zoning
RL
General Plan
LDR
City Limits Within La Quinta Limits
Subdivision Name
TR 29306
Lot Number
61
Centerlines 15764
Lot Size
1703.19
Legal Description
Lot 61 MB 289/77 TR
$134.15
$134.15
29306
Type Group Sq Ft Value
Invoice No. Fee
Fee Amount
Amount Paid
INV -00000506 Credit Card Convenience Fee
$3.27
$3.27
Permit Issuance
$110.88
$110.88
Building Standards Administration
$1.00
$1.00
Technology Enhancement Fee
$8.00
$8.00
Digital Archiving and Records Management Fee - OTC
$11.00
$11.00
Total for Invoice INV -00000506
$134.15
$134.15
Grand Total for Permit
$134.15
$134.15
Workflow Step / Action Name
Action Type
Start Date
End Date
Application Completeness Check v.1
09/07/2023 12:00
09/07/2023 12:00
.......................................................................................................................................................................................................................................................................................................
Submittal Document Verification v.1
....................................................
Generic Action
09/07/2023 12:00
Plan Check v.1
09/07/2023 0:00
09/08/2023 15:52
Building Review (1 Day) v.1
Receive Submittal
09/07/2023 0:00
09/08/2023 15:52
Permit Issuance v.1
09/08/2023 15:52
09/11/2023 14:18
Verify Contractor info & Conditions have been met v.1
Generic Action
09/08/2023 15:52
Verify & Invoice Fees v.1
Generic Action
09/08/2023 15:52
.. ......... ......... ......... ......... .........
Verify Fee Payment & Issue Permit v.1
......... ......... .........
Generic Action
......... ......... .........-
09/11/2023 14:16
Print, Attach, and Email Building Permit v.1
Create Report
09/11/2023 14:19
09/11/2023 14:20
Electrical Inspections v.1
Underground Electrical v.1
9
Inspection
p
Rough Electrical v.1
Inspection
Final Inspections v.1
09/25/2023 0:00
09/27/2023 12:28
Final Electrical v.1
Inspection
09/25/2023 0:00
09/27/2023 12:28
Printed: 1/20/24 12:04 am Page 2 of 3
1-31111111]1Z"a4 N IT, IkI
Permit Type: Electrical
Permit Number: BELC2023-1012
Property Address: 48704 VISTA PALOMINO
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
iurisdiction shall not be valid.
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Printed: 1/20/24 12:04 am Page 3 of 3
=AEC--- M..W s 3..aC
Aw mw
83852 AVENUE 45 INDIO, CA 92201
CA. LIC# 748173
ELECTRICAL LOAD CALCULATION
BELC2023-1012
Cl N OF LA QU N TA
BU LEI N GCI VI S CN
REM EV'ED FOR
CCCE CCIYLJ AN CE
Em J.ANAYA oqE: 09108/2023
INSTALL (1) 240V 40A DEDICATED CIRCUIT AT GARAGE FOR
VEHICLE CHARGING. 2022 CALIFORNIA BUILDING CODES.
CUSTOMER
DR ROBERT ANDERSON 19263364
DATE
September 5, 2023
/
SQUARE FEET LIVING
2,000
3
6,000
GD
1,140
1
1,140
DW
1,128
1
1,128
SMALL APPLIANCES
1,500
3
4,500
MICRO
4,200
0
0
CART CHARGER
1,800
0
0
DUAL FUEL RANGE
4,200
0
0
DOUBLE OVEN
6,250
1
6,250
COOKTOP
720
1
720
WASHER
1,080
1
11080
DRYER
720
1
720
ELECTRIC PATIO HEATERS
0
0
0
WATER COOL
0
0
0
POOL POWER 50 AMP
2,880
3
8,640
LANDSCAPE FUTURE
1,500
1
1,500
TOTAL -KW
31,678
PERCENT
KW
1st 10,000 KW
100%
10,000 10,000
REMAINDER
40%
21,678 8,671
EV CHARGER 40
7,680
1
100%
7,680
FURNACE
1,500
2
100%
3,000
A/C COMPRESSORS #1
6,432
2
100%
12,864
A/C
3,620
0
100%
0
A/C COMPRESSORS #3
3,840
1
100%
3,840
A/C COMPRESSORS #4
0
0
100%
0
TOTAL
46,055
DIVIDED BY
240 V
191.90 AMPS
USE
200 AMP SERVICE
Typical , Installation Wiring
Customer Name_2 _lL r_LTj2+ ---------
Project
_ __ _,^—
Project Address�oK its �I�vr�tt,Jo _�• _____
CI TY OF LA QU N TA
BU LONGONASON
REM EV'ED FCR
COLE COMM AN CE
J.ANAYA -: 09/08/2023
F-1.2 Pole 50 Amp Breaker w/ 6/3 Cu Ramex (in wall)
KT2 Pole LApAmp Breaker w/3#6 Cu + ! #8 Gnd 3/41, Conduit
❑ 2 Pole 50 Amp Breaker wl Combination Of Romex * Conduit
n 2 Pole 60 Amp Breaker w/ 4/3 Cu Romex (in wall)
2 Pole 60 Amp Breaker w/2 #6Cu + #8 Gnd 3/4" Conduit
2 Pole 50 Amp Breaker wl 213 Cu Romex (in Wall)
2 Pole 50 Amp Breaker w/ 2#4 Cu + #8 Gnd I " Conduit
VEr5ting Service 200 Amps
i5ting Service 400 Amps
flenates Outlet or Charging Station location
F1
50-90 Amps
RStandard 40 Amp Charging Station In5tall
❑ Standard GO Amp Charging Station f n5tall
❑Standard 50 Amp Charging Station Install
Hegge Electrical Contractors Inc.
63-852 Ave. 45
Indio, Ca. 92201
Lic# 748 17 1
T-=5 L
T=SLn
Gen 3 Wall Connector Manual
48A Single Phase
PRODUCT OVERVIEW
This manual applies to Wall Connectors identified by part number 1457768-**-*
Product Specifications
Voltage and Wiring
Nominal 200-240 V AC single-phase
Current Output Range
12 - 48 amps
Terminal Blocks
12-4 AWG (3.5 - 25 mm2), copper only
Supported Conduit Sizing
3/ in (21 mm) default, 1 in (27 mm) optional
Grounding Scheme
TN/TT
Frequency
50/60 Hz
Cable Length
7.3 m (24 ft)
Wall Connector Dimensions
Height: 13.6 in (345 mm)
Wire Box Bracket Dimensions
Width: 6.1 in (155 mm)
Depth: 4.3 in (110 mm)
Height: 9.8 in (250 mm)
Width: 4.7 in (120 mm)
Depth: 2.0 in (50 mm)
Weight (including wirebox) 10 Ib. (4.5 kg)
Operating Temperature -22°F to 122°F (-30°C to 50°C)
Storage Temperature -40°F to 185°F (-40°C to 85°C)
Enclosure Rating Type 3R
Ventilation Not required
Means of Disconnect External branch circuit breaker
Ground Fault Circuit Interrupter Integrated, no additional required (CCID20)
Wi-Fi 2.4 GHz, 802.11b/g/n
Agency Approvals cULus - E351001
Transportation and storage: Ensure that Wall Connector is within storage temperature when moving,
transporting, or storing.
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Gen 3 Wall Connector Manual 5
1 PRODUCT OVERVIEW
Circuit Breaker Rating / Maximum Output
Power Output
For maximum power output, install a standard double pole 60 amp circuit breaker. Wall Connector includes
integrated GFCI protection - do not install a GFCI circuit breaker.
Wall Connector incorporates automatic load management, which allows the max output to be customized to
an existing power supply. If the electrical supply is unable to support the 60 amp configuration, select a
lower amperage configuration.
Circuit breaker (amps)
60
50
40
30
20
15
Max output (amps)
48
40
32
24
16
12
Power output at 240 volts (kW)
2` NOTE: External disconnect switches are neither required nor recommended.
11.5
9.6
7.6
5.7
3.8
2.8
LNOTE: Circuit breaker size is programmed during the commissioning process. See Commissioning
Procedure on page 28 for details.
NOTE: Some Tesla vehicles may draw less current than the max output. Actual charging rate depends
on Wall Connector output and onboard charger in the vehicle.
Branch Circuit Conductors and Ground Wire
• If installing for less than maximum power, refer to local electrical code to select correct conductors
and ground wire size that are suitable for the chosen circuit breaker.
• If installing for maximum power, use minimum 6 AWG, 90° C -rated copper wire for conductors.
NOTE: Upsize conductors if necessary.
• For sites with multiple Wall Connectors, each Wall Connector must have its own branch circuit with L1,
L2/N, and Ground.
• COPPER WIRE TERMINATIONS ONLY for landing in Wall Connector wirebox terminals. Conductors
can be stranded or solid.
• Hardwire branch circuits to disconnects or circuit breakers. Do NOT install cord -and -plug type
connections.
• For outdoor installations, use watertight fittings when securing feeder wires to the wirebox.
Gen 3 Wall Connector Manual 6
PRODUCT OVERVIEW
Grounding Connections
Wall Connector must have a ground path back to the main equipment earthing point on site. Without a
proper ground connection, the Wall Connector will fault during a ground assurance test. Equipment -
grounding conductor must be run with the circuit conductors and connected to the equipment -grounding
terminal in the wirebox. Install a ground (PE) wire sized according to local electrical code.
Gen 3 Wall Connector Manual