BSOL2022-0392 - Plan Revision 1-2019 CALIFORNIA ELECTRICAL CODE (CEC)-2019 CALIFORNIA BUILDING CODE (CBC)-2019 CALIFORNIA RESIDENTIAL CODE (CRC)-2019 CALIFORNIA GREEN CODE (CGC)-2019 CALIFORNIA MECHANICAL CODE (CMC)-2019 CALIFORNIA PLUMBING CODE (CPC)-2019 CA FIRE CODE TITLE 24 SUPPLEMENT-ANY OTHER LOCAL AMENDMENTSMACLELLAN, DOUGLAS & NORA RESIDENCEPHOTOVOLTAIC SYSTEM PROJECT (ROOF-MOUNT): 8.000 kW (DC) / 7.360 kW (AC)-METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLESHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BEBONDED IN ACCORDANCE WITH CEC 250.97 & 290.92(B).-FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITHTERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IDENTIFIED ANDLISTED FOR SUCH USE, CEC 690.31(H) & 110.14.-CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORSTHAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTSSHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECTUNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING”, CEC 690.33(C) &(E)(2).-EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY ORCABLE ARMOR, CEC 690.46 & 250.120(C).-THE INTERCONNECTION POINT SHALL BE ON THE LINE SIDE OF ALLGROUND-FAULT PROTECTION EQUIPMENT, CEC 705.32-DC PV SOURCE OR DC PV OUTPUT CIRCUITS SHALL BE CONTAINED INMETAL RACEWAYS, TYPE MC CABLE OR METALLIC ENCLOSURES WHENINSIDE THE BUILDING, CEC 690.31(G).-CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH ASTHOSE NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED, CEC300.4.-PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUSTALSO BE APPROVED BY THE ELECTRICAL UTILITY COMPANY.-FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPESOF NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDED,CEC 250.104.-ALL EXTERIOR CONDUITS SHALL BE PAINTED TO MATCH THE COLOR OFTHE SURROUNDING AREA (ROOF, SIDING, AND STUCCO).-GROUNDING ROD ELECTRODES SHALL BE INSTALLED 8’ MINIMUM INCONTACT WITH SOIL, CEC 250.53(G).-EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, &VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED ORBLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM.-EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLYLOCATED CLOSER THAN 12” FROM THE PROPOSED MODULES, MUST BEREROUTED, OR MUST BE EXTENDED A MINIMUM OF 6” ABOVE THESURFACE OF THE MODULES, CPC 906.1. ·-EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES,WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE EXTENDED 12”ABOVE THE MODULES’ TOP SURFACE, CMC 802.6.2(1) & CPC 509.6.2(1). ·-THE MARKINGS, “WARNING: PHOTOVOLTAIC POWER SOURCE”, FOR DCRACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10’ O.C.; AND BENDS,ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, ORBARRIERS, CEC 690.31(G)(4). ·-PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGSINDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS ONLY NO LOADSARE TO BE CONNECTED. ·-WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTINGELECTRICAL EQUIPMENT, CEC 110.26. ·-RESIDENTIAL TYPE PV CIRCUITS OVER 150-VOLTS TO GROUND MUST NOTBE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED,CEC 690.7(D). ·-A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITHCAL-OSHA REGULATIONS. ·-ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BEINSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. ·-LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZEDAND SHALL BE A MINIMUM HEIGHT OF 3/8’’ IN WHITE ON A REDBACKGROUND. ·-WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKINGMUST BE PROVIDED ON THE PANELBOARD TO INDICATE-GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREAOF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET MINIMUM TOOTHER STRUCTURES AND PROPERTY LINES, CRC R331.3 & R302.1.-705.10 DIRECTORY. A PERMANENT PLAQUE OR DIRECTORY DENOTING THELOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ONOR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENTLOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FORALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEINGINTERCONNECTED. THE MARKING SHALL COMPLY WITH 110.21(B)-705.12 POINT OF CONNECTION. THE OUTPUT OF AN INTERCONNECTEDELECTRIC POWER SOURCE SHALL BE CONNECTED AS SPECIFIED IN705.12(A) OR (B).-ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALLCOMPLY WITH THE FOLLOWING APPLICABLE CODES: - 2019 CBC /2019 IBC - 2019 CRC / 2019 IRC - 2019 CEC / 2017 NEC - 2019 CMC / 2019UMC - 2019 CPC / 2019 UPC - 2019 CFC / 2019 IFC - 2019 BUILDINGENERGY EFFICIENCY STANDARDS-ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDINGALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES.-ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED INACCORDANCE WITH CEC ARTICLE 250.-ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALLHAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDEOVERCURRENT PROTECTION FROM ALL SOURCES, CEC 690.9(A).-ALL EQUIPMENT OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWNINITIATION) SHALL BE LOCATED NEAR THE MAIN ELECTRICALSERVICE EQUIPMENT, CEC 690.13, 690.15.-RAPID SHUTDOWN EQUIPMENT TO PROVIDE CONTROLLEDCONDUCTORS THAT ARE MORE THAN 5 FEET IN LENGTH INSIDE ABUILDING OR MORE THAN 10 FEET FROM A PV ARRAY LIMITATION TONOT MORE THAN 30 VOLTS AND 240 VOLT-AMPERES WITHIN 30SECONDS OF RAPID SHUTDOWN INITIATION, CEC 690.12.-THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLYDE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICALPRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OFVOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTILTHE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORKVOLTAGE HAS BEEN RESTORED, CEC 690.61 & 705.40.-DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVEREXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAYDURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPENCIRCUITING, OR COVERING THE ARRAY WITH OPAQUE COVERING,CEC 690.18.-ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED ANDIDENTIFIED FOR USE IN DIRECT SUNLIGHT, CEC310.10(D) AND690.31(C) THROUGH (G).-ALL CONDUCTORS TO BE OF MATERIAL APPROVED BY THE CODEAND THEIR INSULATIONS TO BE RATED TO NOT LESS THAN 90OC600-VOLTS MINIMUM-INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULESSHALL BE USE-2 OR PV-WIRE TYPE FOR GROUNDED DC SYSTEMS,CEC 690.31(B); AND PV-WIRE TYPE FOR UNGROUNDED DC SYSTEMS,(AS IN TRANSFORMERLESS INVERTERS OR MICROINVERTERS WITHISOLATED GROUNDS), CEC 690.35(D).-FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS ANDTERMINALS LISTED AND MARKED FOR THE USE, CEC 110.14 &690.74(A).-ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END FORUNIQUE IDENTIFICATION, CEC 690.31(B).-ALL GROUNDED, (NEUTRAL), CONDUCTORS’ INSULATION SHALL BESOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC 200.6, 200.7, &400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIREWITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREENWITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OFUNGROUNDED CONDUCTORS SHALL BE OTHER THAN FORGROUNDED, (NEUTRAL)-MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDECONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, CEC705.31.-CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTINGMEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENTON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.12(D).-DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPERACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, CEC690.31(G)-RACEWAYS IN ENCLOSED PORTIONS OF THE BUILDING MUST RUNALONG BOTTOM OF LOAD-BEARING MEMBERS, CC R324.7.2.7.-705.6 EQUIPMENT APPROVAL. ALL EQUIPMENT SHALL BE APPROVEDFOR THE INTENDED USE. INTERACTIVE INVERTERS FORINTERCONNECTIONS TO SYSTEMS INTERACTIVE EQUIPMENTINTENDED TO OPERATE IN PARALLEL WITH THE ELECTRIC POWERSYSTEM INCLUDING, BUT NOT LIMITED TO, INTERACTIVE INVERTERS,ENGINE GENERATORS, ENERGY STORAGE EQUIPMENT, AND WINDTURBINES SHALL BE LISTED AND OR FIELD LABELED FOR THEINTENDED USE OF INTERACTION SERVICE.-705.8 SYSTEM INSTALLATION. INSTALLATION OF ONE OR MOREELECTRICAL POWER PRODUCTION SOURCE(S) OF ELECTRICITYSHALL BE PERFORMED ONLY BY QUALIFIED PERSONS.TITLE SHEET54260 DARK STAR DRLA QUINTA, CA 92253RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022T-1PROPERTY AND BUILDING INFORMATION:HOMEOWNER FULL NAME:MACLELLAN, DOUGLAS & NORAPROPERTY ADDRESS:54260 DARK STAR DR, LA QUINTA, CA 92253APN:780140015OCCUPANCY:R-3TYPE OF CONSTRUCTION:V-BNUMBER OF STORIES:SINGLEMACLELLAN, DOUGLAS & NORASOLAR PHOTOVOLTAIC SYSTEM NOTES:SCOPE OF WORK:PV MODULES:(20) URECO FBM400MFG-BB (400W)OPTIMIZERS:SOLAREDGE P505INVERTER(S):(1) SOLAREDGE SE7600H-US (7600W)PV SYSTEM SQ. FT.:476.0 SQ. FT.ELECTRICAL WORK:(N/A)BATTERIES:(2) SOLAREDGE BAT-10K1P (TOTAL: 20 KWH)GOVERNING CODES:-WORKING CLEARANCES AROUND ALL ELECTRICALEQUIPMENT SHALL BE MAINTAINED IN ACCORDANCEWITH CEC 110.26.-PV EQUIPMENT AND ALL ASSOCIATED WIRING ANDINTERCONNECTIONS SHALL ONLY BE INSTALLED BYQUALIFIED PERSONS. CEC 690.4 (E)-ROOFTOP MOUNTED PV SYSTEM PANELS ANDMODULES SHALL MEET A MINIMUM FIRECLASSIFICATION AS REQUIRED BY R902.4 AND CBC1505.9.-ROOF ACCESS POINTS. ROOF ACCESS POINTS SHALLBE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGSSUCH AS WINDOWS OR DOORS, AND LOCATED ATSTRONG-POINTS OF BUILDING CONSTRUCTION IN LOCATIONSWHERE THE ACCESS DOES NOT CONFLICT WITHOVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS (R331.4.1).LADDERS SHALL BE OSHAAPPROVED AND SECURED TO THE STRUCTURE FORINSPECTION PURPOSES.CONTRACTORS AREREQUIRED TO BE PRESENT FOR THE FIRST AND/ORFINAL INSPECTIONS.-APPROVED SMOKE AND CARBON MONOXIDE ALARMSARE REQUIRED WITHIN THE DWELLING UNIT ANDSHALL BE FIELD VERIFIED EITHER THROUGH FINALBUILDING INSPECTION. SMOKE ALARMS AREREQUIRED TO BE INSTALLED IN ALL BEDROOMS,OUTSIDE EACH BEDROOM, AND AT LEAST ONE ONEACH FLOOR OF THE HOUSE. CARBON MONOXIDEALARMS ARE REQUIRED OUTSIDE EACH BEDROOMAND AT LEAST ONE ON EACH FLOOR OF THE HOUSE.R314.1, R315.1-ALL WORK SHALL COMPLY WITH THE CURRENTCALIFORNIA CODE OF REGULATIONS TITLE 24 ANDMANUFACTURER'S LISTINGS.-PRIOR TO CALLING FOR FINAL INSPECTION, THECONTRACTIOR SHALL:1.BE COMPLETED WITH THE WORK.2.HAVE A LADDER IN PLACE AND SECURED TO THEROOF.3.HAVE THE SYSTEM ENERGIZED READY FOR THERAPID SHUTDOWN VERIFICATION BY THE CITYINSPECTOR.GENERAL NOTES:TABLE OF CONTENTS:T-1TITLE PAGED-1SITE PLAND-2PLOT PLAND-3STRUCTURAL DETAILSE-1SINGLE LINE DIAGRAMP-1PLACARDSS-1+EQUIPMENT SPEC SHEETS 12/08/2022BSOL2022-0392REVISION 1: CHANGED PANEL QUANTITY AND TYPE, (20)400W URECO FBM PANELS, NO OTHER CHANGES TOSYSTEM ATTRIBUTES. 7.92kW SOLAR ARRAY - (18) 440W URECOPANELS+SOLAREDGE P505 OPTIMIZERS W/(1)SOLAREDGE SE7600H-US INVERTER, (1) SOLAREDGEBACK UP INTERFACE AND (2) SOLAREDGE 10KWHENERGY BANK BATTERIES [428SF] 2019 CALIFORNIAELECTRICAL CODE.
DARK STAR DRPROPERTY LINE(E)
D
R
I
V
E
W
A
Y (E) POOL(E) PATIOSITE PLAN54260 DARK STAR DRLA QUINTA, CA 92253D-1RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022MACLELLAN, DOUGLAS & NORA1/16" = 1'-0" 12/08/2022BSOL2022-0392REVISION 1
3'3'1'-6"AC
MP
IN JBBA
BA
BI
BS
PLOT PLAN54260 DARK STAR DRLA QUINTA, CA 92253D-2RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022PV SYSTEM INFO:PV MODULES:(20) URECO FBM400MFG-BBINVERTER(S):(1) SOLAREDGE SE7600H-USMOUNTING TYPE:ROOF MOUNTEDROOF MATERIAL:CONCRETE S. TILEROOF FRAMING:2X4 @ 24" O.C.MAX SPAN:8'-0"ROOF SLOPE:18°AZIMUTH(S):23°MACLELLAN, DOUGLAS & NORALEGENDJB(N) NEMA-3R JUNCTION BOXIN (N) SOLAREDGE INVERTERAC(N) AC DISCONNECTMP(E) MAIN DISCONNECT & UTILITY METERBI(N) SOLAREDGE BACKUP INTERFACEBS(N) BACKUP SUBPANELBA(N) SOLAREDGE BAT-10K1P BATTERY UNIT3/32" = 1'-0"GENERAL NOTES:-ALL CONDUIT ON ROOF TO BE INSTALLED7/8" OR MORE OFF ROOF SURFACE-A CLEARANCE OF AT LEAST 30 INCHES WIDEAND 36 INCHES DEEP SHALL BE PROVIDEDAROUND ALL ELECTRICAL EQUIPMENT. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRETHE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWSOR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.= FIRE PATHWAY= ROOF ACCESS POINTROOF AREA COVERAGETOTAL ROOF AREA (SQ. FT.):5094.00TOTAL PV AREA (SQ. FT.):476.0TOTAL % OF ROOF COVERAGE (ALL MODULES):9.34%ARRAY 1:TILT: 20°AZIMUTH: 23°R E G I S T E R E D P R O F E S S I O N A L E N G I N E E RC I V I LNo. C70784Exp. 06/30/2023S T A T E O F C A L I F O R N I APHONG TRUONG 12/08/2022BSOL2022-0392REVISION 1
L-Bracket(2)5/16" x 3-1/2"SS Lag Bolt w/2.5" Min. PenetrationPEGASUSTile Replacement2X4 @ 24" O.C.IRONRIDGESolar RailingMAX SPAN: 8'-0"ROOF FRAMING: 2X4 @ 24" O.C.ROOF FRAMINGIRONRIDGE RACKINGw/ PEGASUS ATTACHMENTSNote:Arrays are supported at aMaximum of 6 feet horizontalspacing.Panels shall have 3-inchclearance from the roofsurface to the lowestedge of panel/ supportframing. Highest edge ofpanel will not be over24" above roof surface.D-31STRUCTURAL DETAILS54260 DARK STAR DRLA QUINTA, CA 92253D-3RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022MACLELLAN, DOUGLAS & NORAN.T.S2TYP. ATTACHMENT LAYOUTN.T.SELEVATION FOR TYP. SOLAR ARRAY31N.T.SROOF ATTACHMENT DETAILR E G I S T E R E D P R O F E S S I O N A L E N G I N E E RC I V I LNo. C70784Exp. 06/30/2023S T A T E O F C A L I F O
R
N I APHONG TRUONG 12/08/2022BSOL2022-0392REVISION 1
MAXIMUM SYSTEM VOLTAGE [NEC 690.7]VOLTAGE CORRECTIONFACTOR:1.12MODULE Voc:37.201ADJUSTED VOLTAGE (V):41.66MAXIMUM VOLTAGE (V):83.0 V54260 DARK STAR DRLA QUINTA, CA 92253SINGLE LINE DIAGRAME-1RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022MODULE SPECIFICATIONS:MANUFACTURER:URECOMODEL NO.:FBM400MFG-BBPEAK POWER:400 WVoc:37.20 VVmp:31.17 VIsc:13.68 AImp:12.84 AOCPD CALCULATIONS:MAX AC OUTPUT (AMPS)125%RESULT (AMPS)OCPD SIZE(AMPS)32.001.2540.0040.00CEC 705.12(D)(2)(3)(B)WHERE TWO SOURCES, ONE A UTILITY AND THE OTHER AN INVERTER,ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS,THE SUM OF 125% OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT ANDTHE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBARSHALL NOT EXCEED 120% OF THE AMPACITY OF THE BUSBAR.AC NAMEPLATE ELECTRICAL CALCULATIONSMODULE PTCRATING:# OFMODULES:INVERTEREFFICIENCYRATING (%)SYSTEM ACNAMEPLATERATING (kW)375.50200.987.360DC WIRE/CONDUIT SCHEDULE:TAGCONDUITTYPECONDUCTORQTY.CONDUCTORSIZECONDUCTORTYPEWIRE RATING(AMPS)CONDUIT FILLDERATETEMP.DERATEADJUSTEDWIREAMPERAGECIRCUIT ISCCIRCUIT ISC* 1.25 * 1.25GNDSIZEGNDTYPE1FREE AIR2 (1+, 1-)#12PV WIRE401.00.9136.4015.018.75#6BARE23/4" EMT4 (2+, 2-)#10THWN-2400.80.9129.1215.018.75#8THWN-2AC WIRE/CONDUIT SCHEDULE:TAGCONDUITTYPECONDUCTORQTY.CONDUCTORSIZECONDUCTORTYPEWIRE RATING(AMPS)CONDUIT FILLDERATETEMP.DERATEADJUSTEDWIREAMPERAGECIRCUITAMPSCIRCUITAMPS * 1.25GNDSIZEGNDTYPE33/4" EMT3 (1+, 1-, 1N)#8THWN-2551.00.9150.0532.040.00#8THWN-2MACLELLAN, DOUGLAS & NORAMICROINVERTER SPECIFICATIONS:MANUFACTURER:SOLAREDGEMODEL NO.:SE7600H-USPEAK POWER:7600 WMAX INPUT VOLTAGE:480 VNOMINAL AC VOLTAGE:240 VMAX AC CURRENT:1.21 A(TOTAL COMBINED)MODULES PER DCOPTIMIZER:GENERAL NOTES:-ALL MODULES WILL BE GROUNDED INACCORDANCE WITH CODE AND THEMANUFACTURER'S INSTALLATIONINSTRUCTIONS-ALL PV EQUIPMENT SHALL BE LISTED BY ARECOGNIZED TESTED LAB-SERVING UTILITY WILL BE NOTIFIED BEFOREACTIVATION OF PV SYSTEM-WHEN A BACKFED BREAKER IS THE METHODOF UTILITY INTERCONNECTION, THEBREAKER SHALL NOT READ LINE AND LOAD-WHEN A BACKFED BREAKER IS THE METHODOF UTILITY INTERCONNECTION, THEBREAKER SHALL BE INSTALLED ON THE ENDOF THE BUSBAR FARTHEST AWAY FROM THEMAIN BREAKER-WORK CLEARNACES AROUND ELECTRICALEQUIPMENT WILL BE MAINTAINED PER NEC110.26(a)(1), 110.26(a)(3)-ALL METALLIC RACEWAYS AND EQUIPMENTSHALL BE BONDED AND ELECTRICALLYCONTINUOUS.-ALL PV EQUIPMENT, SYSTEMS AND ALLASSOCIATED WIRING ANDINTERCONNECTIONS SHALL BE INSTALLEDBY QUALIFIED PERSONS.-THE PHOTOVOLTAIC SYSTEM CONDUCTORSSHALL BE INDENTIFIED AND GROUPED. THEMEANS OF IDENTIFICATION SHALL BEPERMITTED BY SEPARATED COLOR CODING,MARKING TAPE, TAGGINGS OR OTHERAPPROVED MEANS. (NEC 690.4(B)-MODULES AND RAILS SHALL BEELECTRICALLY BONDED TO GROUND VIARAIL INTEGRATED BONDING UL2703 LISTEDGROUNDING METHOD.-THE PHOTOVOLTAIC SYSTEM IS RAPIDSHUTDOWN COMPLIANT PER CEC 690.12-ALL CONDUIT ON ROOF TO BE INSTALLED7/8" OR MORE OFF ROOF SURFACEGROUNDING NOTES:-COLD WATER BOND TO BE INSTALLEDWITHIN 5 FEET-2 SUPPLEMENTAL GROUND RODS-(5/8" DIA., 8'-0") SHALL BE INSTALLED ATLEAST 6' APART IF EXISTING UFER IS NOTFOUND-CONNECTION TO THE INTERIOR METALWATER PIPING SHALL BE MADE WITH #4ARMORED CABLE WITHIN 5 FT. OF THE POINTOF ENTRANCEGROUNDING DETAIL FOR SOLAR ARRAY:*UL 486B listed,AL9CU rated. Forcopper and aluminumconductorcombinations up to90° C, 600 Voltapplications. ULRecognized forgrounding, bonding,and direct burial.Equipment Grounding (c16.10)System Grounded at MainService PanelUnderside ofSolar Panels#6 Copper Equipment GroundingConductor ThroughoutAC DisconnectGround Lug used forEquipment GroundingConductor16A Bypass Diodelocated here at PVjunction box (typ.)Max Voltage: 600VSolar RailsGrounding ConductorStainless ScrewMODULEFRAMEIlsco Grounding Lug*#GBL-4DBTStainless Screwinstalled per manufacturer'sspecificationsMECHANICAL GROUND LUG DETAIL FOR RACKING AND MODULES:SERVICE LOAD CALCULATIONS:BUSBAR RATING(AMPS)MULTIPLIER(120%)RESULT2001.20240.00MAIN BREAKERRATING (AMPS)INVERTEROUTPUT * 125%ALLOWABLE BACK FEED20040.0040.00INVERTER OUTPUT (40.00A) </= ALLOWABLE BACKFEED (40A)THEREFORE OKGDCAC(N)NEMA 3RJUNCTION BOX23(N) 1 - BATTERYBAT-10K1P(2) #10 THWN-2(1) #8 AWG GEC(5) #24 AWG - RS4853/4 EMT"1G(N) 40APVBREAKER(N)200A BACKUPSUBPANEL(3) 3/0 THWN-2 CONDUCTORS(1) #2 AWG GEC2" EMT CONDUIT(N) 200ASUBPANELBREAKERBACKUP LOADS
(N)SOLAREDGEBI-NUSGN-01BACKUPINTERFACE(N)SOLAREDGE SE7600H-USINVERTER (W/ INTEGRATEDDC DISCONNECT)1 STRING OF (10) MODULESW/ SOLAREDGE SOLAREDGE P505OPTIMIZERS1 STRING OF (10) MODULESW/ SOLAREDGE SOLAREDGE P505OPTIMIZERS(N)60A NON-FUSEDAC DISCONNECTDU222RB(LOCKABLE IN THEOFF POSITION,NON-FUSED WITHVISIBLE BLADES)200A LUGSFOR BACKUPSUBPANELGN(E) 400A SPLIT-BUS MAIN SERVICE PANEL240V, 1-PHASE, 3WM(E) 200AMAINBREAKER(END-FED)(E) 200AMAINBREAKER(END-FED)(E) #4 GEC3(N) 1 - BATTERYBAT-10K1P(E) (2) 3/0 THWN-2WITHIN 2" EMTEXTERNAL RAPIDSHUT DOWNSWITCHREQUIRED 12/08/2022BSOL2022-0392REVISION 1
NACMPINJBBABABIBSPLACARDS54260 DARK STAR DRLA QUINTA, CA 92253P-1RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022WARNINGPANEL CONTAINS D.C. SOLAR POWERSYSTEM DISCONNECT MAY NOT DE-ENERGIZE ALL POWER SOURCESInstall on DC DisconnectWARNING:INVERTER OUTPUT CONNECTION. DO NOTRELOCATE THIS OVERCURRENT DEVICE.Install on Inverter(s) output connection.WARNING: ELECTRIC SHOCK HAZARD IF AGROUND FAULT IS INDICATED, NORMALLYGROUNDED CONDUCTORS MAY BEUNGROUNDED AND ENERGIZEDInstall on InverterSign and Markings Format:(1) White lettering on redbackground(2) Minimum 3/8 - inch letterheight(3) All letters to be capitalized(4) Arial or similar font, non-bold(5) Signage - permanentreflective weather resistantmaterial suitable for theenvironment(6) Plaques shall be metal orplastic with engraved ormachine printed letters orelectro-photo plating, in acontrasting color. The plaqueshall be attached to serviceequipment with rivetsor screws.Typical CautionSignage per CEC690 Requirements:MACLELLAN, DOUGLAS & NORAInstall on Main PanelPHOTOVOLTAIC SYSTEM EQUIPPEDWITH RAPID SHUTDOWN!SOLAR ELECTRICPV PANELSInstall on Main PanelTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUTDOWN PV SYSTEM ANDREDUCE SHOCK HAZARDIN THE ARRAYMAXIMUM SYSTEM VOLTAGE: 480 VMAXIMUM CIRCUIT CURRENT: 20.0 AMAX RATED OUTPUTCURRENT OF THE CHARGECONTROLLER OR DC-TO-DCCONVERTER (IF INSTALLED): N/AInstall on InverterPV INVERTER DC DISCONNECTCOMPLETE SYSTEM SHUTDOWN IS ACHIEVED BYINITIATING THE RAPID SHUTDOWN DEVICE ANDENSURING THIS DC DISCONNECT IS IN THE OFFPOSITION.Install on Inverter and Main Service PanelCAUTION: DUAL POWER SOURCESECOND SOURCE IS AC BATTERYInstall on Service Disconnect and Subpanels WARNING: THIS EQUIPMENT FED BY MULTIPLESOURCES. TOTAL RATING OF ALL OVERCURRENTDEVICES, EXCLUDING MAIN SUPPLY OVERCURRENTDEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR.Install on Battery Subpanel and panels that comply with CEC 705.12(D)(2)(3)(c)CAUTION: TRI POWER SOURCE SECONDSOURCE IS AC BATTERY THIRD SOURCE ISPHOTOVOLTAIC SYSTEMInstall on Service Disconnect and SubpanelsWARNING: ELECTRIC SHOCK HAZARD IF AGROUND FAULT IS INDICATED, NORMALLYGROUNDED CONDUCTORS MAY BE UNGROUNDEDAND ENERGIZEDInstall on Batteries and InvertersWARNING:TURN OFF PHOTOVOLTAIC AC DISCONNECTSPRIOR TO WORKING INSIDE PANELInstall on AC service section and all AC sub-PanelsTHIS SERVICE IS FED FROM MULTIPLE SOURCES: GRID AND PV ARRAYInstall on Main ServiceWARNING: ELECTRICAL SHOCK HAZARDDO NOT TOUCH TERMINALS. TERMINALS ONBOTH LINE AND LOAD SIDES MAY BEENERGIZED IN THE OPEN POSITIONInstall on pull boxes with internal terminalsCAUTION:PHOTOVOLTAIC SYSTEMCIRCUIT BREAKER IS BACKFEDInstall on Point of ConnectionPlace every 10 feet on all interior and exterior DCconduits, raveways, enclosures,and cable assemblies,at turns, above and /or below penetrations,all DCcombiners, and junction boxes.WARNING: PHOTOVOLTAICPOWER SOURCEInstall on AC DisconnectWARNING -DUAL POWERSUPPLY PHOTOVOLTAICSYSTEMInstall of face of all sub panels and electrical service panelPHOTOVOLTAIC SYSTEM EQUIPPEDWITH RAPID SHUTDOWNInstall on Main PanelRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEMInstall on rapid shutdown deviceWARNING: POWER SOURCE OUTPUTCONNECTION - DO NOT RELOCATE THISOVERCURRENT PROTECTION DEVICEInstall on Main ServiceCAUTIONMULTIPLE SOURCES OF POWERPHOTOVOLTAIC SYSTEM AC DISCONNECTOPERATING CURRENT: 32.00 AOPERATING VOLTAGE: 240VMAIN PANELAC DISCONNECT 12/08/2022BSOL2022-0392REVISION 1
MODULE SPEC SHEET54260 DARK STAR DRLA QUINTA, CA 92253S-1RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022MACLELLAN, DOUGLAS & NORA
INVERTER SPEC SHEET54260 DARK STAR DRLA QUINTA, CA 92253S-2RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022MACLELLAN, DOUGLAS & NORA
INVERTER SPEC SHEET54260 DARK STAR DRLA QUINTA, CA 92253S-3RESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022MACLELLAN, DOUGLAS & NORA
54260 DARK STAR DRLA QUINTA, CA 92253BACKUP INTERFACE SPECS-4MACLELLAN, DOUGLAS & NORARESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022
ATTACHMENT SPECRESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022MACLELLAN, DOUGLAS & NORA54260 DARK STAR DRLA QUINTA, CA 92253S-5
BATTERY SPEC SHEET54260 DARK STAR DRLA QUINTA, CA 92253S-6MACLELLAN, DOUGLAS & NORARESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022
HEAT ALARM SPEC SHEET54260 DARK STAR DRLA QUINTA, CA 92253S-7MACLELLAN, DOUGLAS & NORARESIDENCE NAME:JOBSITE ADDRESS:TO SCALE ON (11x17) PAPER9/28/2022