BSOL2021-0062 - PlansB PV1TITLE PAGEVICINITY MAP PROJECT DESCRIPTION 7.04 KW ROOF MOUNTED PHOTOVOLTAIC ELECTRICAL SYSTEM 22-SUNERGY 320W MODULES 1-SUNNY BOY 7.0 US 240V INVERTER ASPHALT SHINGLE TILT 15° SHEET #: START DATE: 12/17/2020 PRINT DATE:Jun 3, 2021 (5:31 PM) DWG. SCALE:NOTED DRAWN BY: ARMANDO CARDENAS RAUL RESIDENCE PROJECT INFORMATION: OWNER: ADDRESS: 53595 AVENIDA VALLEJO. LA QUINTA, CA 92253 CONTRACTOR SIGNATURE XPHOTOVOLTAIC GENERAL NOTES 1. ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: 2. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION INTAKE OR OPENINGS SHALL NOT BE COVERED BY PHOTOVOLTAIC SYSTEM. 3. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURERS INSTRUCTIONS. (NEC 690.4(D)) 4. ALL OUTDOOR EQUIPMENT SHALL BE NEMA3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 5. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250 6. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVER CURRENT DEVICES LOCATED SO AS TO PROVIDE OVER CURRENT PROTECTION FROM ALL SOURCES [NEC 690.9(A)] 7. ALL PHOTOVOLTAIC (PV) MODULES SHALL BE MOUNTED ON THE ROOF. ADDITIONAL EQUIPMENT OF THE PV SYSTEM SHALL BE LOCATED OUTSIDE THE BUILDING NEAR THE MAIN ELECTRICAL SERVICE [NEC 690.14(C)] 8. THE UTILITY INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE GRID PROVIDER VOLTAGE HAS BEEN RESTORED [NEC 690.61] 9. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING OR COVERING THE ARRAY [NEC 690.18] 10. ALL CONDUIT EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT [NEC 690.31(B) 310.10(D)] 11. THE MODULE CONDUCTORS MUST BE TYPE USE-2 ORL LISTED FOR PHOTOVOLTAIC (PV) WIRE [NEC 690.31(B)] 12. ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION. 14. ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS AND LABELS SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY INSPECTION TO BE PERFORMED BY THE BUILDING DEPARTMENT INSPECTOR. 15. PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING [NEC 690.64 & 705.12] A.EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING MEANS [NEC 705.12(D)(1)] B.THE SUM OF OF THE AMPERE RATING OF THE OVER CURRENT DEVICES IN CURRENTS SUPPLYING POWER TO THE BUS BAR OR CONDUCTOR SHALL NOT EXCEED 120% OF THE RATING OF BUS BAR OR CONDUCTOR [NEC 705.12(D)(2)] C.THE INTERCONNECTION POINT SHALL BE ON THE LINE SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT [NEC 705.32] D.EQUIPMENT CONTAINING OVER CURRENT IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. [NEC 705.12 (D)(4)] E.CIRCUIT BREAKER, IF BACKFEED SHALL BE SUITABLE FOR SUCH OPERATION [NEC 705.12(D)(5) F.TO MINIMIZE OVERHEATING OF THE BUS BAR IN THE PANEL BOARD MAIN CIRCUIT BREAKER AND THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE PHYSICALLY LOCATED AT THE OPPOSITE END OF THE BUS BAR. 16. METALLIC RACEWAYS OR METALLIC ENCLOSURES ARE REQUIRED METHOD FOR INSIDE A BUILDING FOR PV SYSTEM. [NEC 690.31(E)] 17. FLEXIBLE, FINE STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTORS THAT ARE IDENTIFIED AND LISTED FOR SUCH USE. [690.31(E)] 18. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING OVER 30 VOLTS SHALL REQUIRE A TOOL TO OPEN AND SHALL BE MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING" [NEC 690.33(C) & (E)(2) 19.EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN #6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY RACEWAY OR CABLE ARMOR, [NEC 690.46 & 250.120(C)] 20. EQUIPMENT GROUNDING CONDUCTOR FOR PV SYSTEMS WITHOUT GROUND FAULT PROTECTION (GFP) AND INSTALLED ON NON-DWELLING UNIT MUST HAVE AMPACITY OF AT LEAST 2 TIMES THE TEMPERATURE AND CONDUIT FILL CORRECTED CIRCUIT CONDUCTOR AMPACITY. [NEC 690.45(B)] 21. FINE STRANDED CABLES USED FOR BATTERY TERMINALS DEVICES AND CONNECTIONS REQUIRE LUGS AND TERMINALS LISTED AND MARKED FOR THAT USE [NEC 690.74] PROJECT INFORMATION PROJECT NAME: PROJECT ADDRESS: BUILDING DEPARTMENT JURISDICTION: PV SYSTEM SIZE IN KILOWATTS: UTILITY INTERACTIVE: CONTRACTOR: CONTACT NUMBERS: ADDRESS: CONTRACTOR LICENSE NUMBER: 53595 AVENIDA VALLEJO. LA QUINTA, CA 92253 RAUL RESIDENCE CITY OF LA QUINTA 7.04 KW UTILITY INTERACTIVE GOT SOLAR POWER (760) 912-2700 30636 SHERWOOD ST LUCERNE VALLEY, CA 9235 LIC. # 890815 A.P.N.774-122-017 NOTE: ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE BSOL2021-0062 7.04kW SOLAR ARRAY - (22) 320W SUNERGY SUN 72P-35F PANELS W/ (1) SUNNYBOY 7.0-US INVERTER [396SF] 2019 CALIFORNIA BUILDING CODES. 06/04/2021 DRIVEWAY POOL RESIDENCEPROPERTY LINEPROPERTY LINE AVENIDA VALLEJOPROPERTY LINE PROPERTY LINESCALE : 1/16" = 1'-0" 2'-0"0'-0"4'-0"8'-0"16'-0"TILT 15°AZIMUTH 180PV2SITE PLANPROJECT DESCRIPTION 7.04 KW ROOF MOUNTED PHOTOVOLTAIC ELECTRICAL SYSTEM 22-SUNERGY 320W MODULES 1-SUNNY BOY 7.0 US 240V INVERTER ASPHALT SHINGLE TILT 15° SHEET #: START DATE: 12/17/2020 PRINT DATE:Jun 3, 2021 (5:31 PM) DWG. SCALE:NOTED DRAWN BY: ARMANDO CARDENAS RAUL RESIDENCE PROJECT INFORMATION: OWNER: ADDRESS: 53595 AVENIDA VALLEJO. LA QUINTA, CA 92253 CONTRACTOR SIGNATURE XEQUIPMENT ELEVATION NOTES: 1. ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY ( I.E. UL ETC) 2. ALL WIRING MATERIAL SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 3. WHERE THE TERMINAL OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS,. THE SIGN SHALL BE CLEARLY LEGIBLE AND HAVE THE FOLLOWING WORDS:ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 4. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM PHYSICAL DAMAGE. 5. IN ONE AND TWO FAMILY DWELLINGS, LIVE PARTS IN PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150 VOLTS TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENGERGIZED. 6. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR DISPLACEMENT OF A MODULE(S) OR PANEL(S) SECURED BY REMOVABLE FASTENERS. 7. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 8. THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING ROOF COVERING MATERIAL CONDUIT FROM ARRAY NORTH (E) 200A MAIN PANEL W/200A MCB (N) 40A BACKFEED BREAKER (E) 200A MAIN PANEL W/200A MCB (N) 40A BACKFEED BREAKER (N) SUNNY BOY 7.0-US (N) SUNNY BOY 7.0-US (N) 60 AMP A/C DISCONNECT (N) 60 AMP A/C DISCONNECT 06/04/2021 SYSTEM SPECIFICATIONS PV SYSTEM MODULES NUMBER OF MODULES MODULES PER STRING INVERTER MANUFACTURER INVERTER MODEL NUMBER OF INVERTERS ROOF MATERIAL ROOF SLOPE, RISE/RUN MOUNTING EQUIPMENT RACKING SYSTEM PV SYSTEM WEIGHT, LBS/ SF AREA OF PV ARRAY PERCENTAGE OF ROOF COVERED SUNERGY 320W 2X11 SUNNY BOY 7.0 SB-7.0-US 1 ASPHALT SHINGLE 15° UNIRAC UNIRAC 2.57 LBS/SF 387.2 SF 24.6% HEIGHT ABOVE ROOF 3"-5" 22 CONDUIT DETAIL (TYP) 3/4" EMT CONDUIT ROOF LEVEL SS 3/4 " EMT STRAP WOOD 1 1 2" MIN. B B A A A A A A A AAAA B B B B B B B B B 4' 1'-4" J1 JUNCTION BOX (TYP) SCALE : 3/32" = 1'-0" 2'-0"0'-0"4'-0"8'-0"16'-0" PV3PV LAYOUT1. ALL ELECTRICAL SYSTEMS SHALL COMPLY WITH THE LATEST N.E.C. 2. ALL ROOFING PENETRATIONS SHALL EMBED IN STRUCTURAL MEMBERS AND PROPER FLASHING SEALANT SHALL BE USED TO PROVED WATERTIGHT ASSEMBLY. 3. NO PLUMBING OR MECHANICAL VENT SHALL BE COVERED BY COLLECTORS. GENERAL NOTES PROJECT DESCRIPTION 7.04 KW ROOF MOUNTED PHOTOVOLTAIC ELECTRICAL SYSTEM 22-SUNERGY 320W MODULES 1-SUNNY BOY 7.0 US 240V INVERTER ASPHALT SHINGLE TILT 15° SHEET #: START DATE: 12/17/2020 PRINT DATE:Jun 3, 2021 (5:31 PM) DWG. SCALE:NOTED DRAWN BY: ARMANDO CARDENAS RAUL RESIDENCE PROJECT INFORMATION: OWNER: ADDRESS: 53595 AVENIDA VALLEJO. LA QUINTA, CA 92253 CONTRACTOR SIGNATURE XTRIBUTARY AREA PER MOUNT: 10.8 SF (E) 2"X6" ROOF STRUCTURE @ 16" O.C. (TYP) MAX SPAN OF 8'-0" (N) MOUNTS @ 48" O.C. (TYP) 06/04/2021 3 4" EMT CONDUIT 2- #8 THWN-2 1- #8 NEUTRAL 1- #6 GROUND INV A JUNCTION BOX (TYP) A Δ2 Δ1 B 2- #10 PV WIRE 1- #6 GROUND Δ0 (E) AC GROUNDING ELECTRODE 40A TO EXISTING LOADS 200A G (E) UTILITY METER #6 BARE COPPER GROUND (TYP) EGC #6 BARE COPPER GROUND (TYP) EGC 1 11B 1 A11 (N) SUNNY BOY 7.0-US (E) 200A MAIN PANEL W/200A MCB (N) 40A BACKFEED BREAKER 3/4" EMT CONDUIT 4- #10 THWN-2 1- #8 GROUND (N) 60 AMP A/C DISCONNECT PV4THREE LINEDIAGRAM7.15 KW ROOF MOUNTED PV SYSTEM WARNING A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT WITH THE FOLLOWING OR EQUIVALENT MARKING INVERTER OUTPUT CONNECTION DO NOT RELOCATE OVERCURRENT DEVICE BUSS BAR CALCULATION 200 AMP X 1.2 = 240 AMP 240 AMP - 200 AMP MCB = 40 AMP ALLOWABLE BACKFEED PROJECT DESCRIPTION 7.04 KW ROOF MOUNTED PHOTOVOLTAIC ELECTRICAL SYSTEM 22-SUNERGY 320W MODULES 1-SUNNY BOY 7.0 US 240V INVERTER ASPHALT SHINGLE TILT 15° SHEET #: START DATE: 12/17/2020 PRINT DATE:Jun 3, 2021 (5:32 PM) DWG. SCALE:NOTED DRAWN BY: ARMANDO CARDENAS RAUL RESIDENCE PROJECT INFORMATION: OWNER: ADDRESS: 53595 AVENIDA VALLEJO. LA QUINTA, CA 92253 CONTRACTOR SIGNATURE XΔ1 Δ2 INVERTER A DATA (provided by manufacturer) MAKE OF INVERTER MODEL NUMBER MAX. DC VOLT RATING MAX. POWER @ 40 C NOMINAL AC VOLTAGE MAX. AC CURRENT MAX. OCPD SUNNY BOY 7.0 - US 480V 7750W 211-264V @ 240V 29.2A INCLUDED SYSTEM NOTES: 1- SUNNY BOY 7.0-US 240V INVERTER 2 STRINGS OF 11 22 MODULES TOTAL CALCULATIONS: INVERTER A MAX SYSTEM VOLTAGE = 240V MAX CIRCUIT CURRENT = 18A X1.25 = 22.50A AC OUTPUT: 29.2A X 1.25 =36.50A MODULE DATA (provided by manufacturer) MODULE RATINGS AT STC (Standard Test Conditions MAKE OF MODULE MODEL NUMBER MAX. POWER POINT (MPP) CURRENT (IMPP) MAX. POWER POINT (MPP) VOLTAGE (VMPP) OPEN CIRCUIT VOLTAGE (VOC) SHORT CIRCUIT CURRENT (ISC) MAX. SERIES FUSE (OCPD) MAX. POWER (PMAX) MAX. VOLTAGE (TYPICAL LESS THAN 600V DC) SUNERGY 320W SUN 72P-35F 8.53A 37.5V 44.6V 9.03A 15A 320W 1000V 06/04/2021 LABEL # 5 A/C DISCONNECT INVERTER JUNCTION BOX PV PANEL ARRAY LABEL # 6,12 LABEL # 5 LABEL # 5 LABEL # 9, 12 LABEL # 3, 8 LABEL # 1, 4, 7, 8, 10, 13, 14 MAIN SERVICE PANEL NOTE: THIS IS A GENERIC DIAGRAM INTENDED FOR THE LOCATION OF WARNING LABELS. NOT ALL EQUIPMENT DEPICTED HERE MAY BE A PART OF THIS PROJECT, OR IN THIS ORDER CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN YOU ARE HERE A/C DISCONNECT ON GROUND FLOOR PV ARRAY PV5WARNINGLABELSLABELING AND WARNING SIGNS A. PURPOSE PROVIDE EMERGENCY RESPONDERS WITH APPROPRIATE WARNING AND GUIDANCE WITH RESPECT TO ISOLATING THE SOLAR ELECTRIC SYSTEM. THIS CAN FACILITATE IDENTIFYING ENERGIZED ELECTRICAL LINES THAT CONNECT THE SOLAR PANELS TO THE INVERTER, AS SHOULD NOT BE CUT WHEN VENTING FOR SMOKE REMOVAL. B. MAIN SERVICE DISCONNECT: 1. RESIDENTIAL BUILDINGS- THE MARKING MAY BE PLACED WITHIN THE MAIN SERVICE DISCONNECT. THE MARKING SHALL BE PLACED ON THE OUTSIDE COVER IF THE MAIN SERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED. 2. COMMERCIAL BUILDINGS- THE MARKINGS SHALL BE PLACED ADJACENT TO THE MAIN SERVICE DISCONNECTCLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED 3. MARKINGS, VERBIAGE, FORMAT AND TYPE OF MATERIAL a. VERBIAGE: CAUTION; SOLAR ELECTRIC SYSTEM CONNECTED b. FORMAT: (1) WHITE LETTERING ON A RED BACKGROUND (2) MINIMUM 3/8 INCH LETTER HEIGHT (3) ALL LETTERS SHALL BE CAPITALIZED (4) ARIAL OR SIMILAR FONT, NON-BOLD c. MATERIAL: (1) REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969) AS STANDARD FOR WEATHER RATING): DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. C. MARKING REQUIREMENTS ON DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, DC COMBINERS AND JUNCTION BOXES; 1. MARKING: PLACEMENT, VERBIAGE, FORMAT AND TYPE OF MATERIAL. a. PLACEMENT: MARKINGS SHALL BE PLACED EVERY 10 (TEN) FEET ON ALL INTERIOR AND EXTERIOR DC CONDUITS, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES, AT TURNS ABOVE AND/OR BELOW PENETRATIONS, ALL DC COMBINERS AND JUNCTION BOXES. b. VERBIAGE: CAUTION SOLAR CIRCUIT c. THE FORMAT AND TYPE OF MATERIAL SHALL ADHERE TO SECTION B-3.B & C ABOVE D. INVERTERS ARE NOT REQUIRED TO HAVE CAUTION MARKINGS PROJECT DESCRIPTION 7.04 KW ROOF MOUNTED PHOTOVOLTAIC ELECTRICAL SYSTEM 22-SUNERGY 320W MODULES 1-SUNNY BOY 7.0 US 240V INVERTER ASPHALT SHINGLE TILT 15° SHEET #: START DATE: 12/17/2020 PRINT DATE:Jun 3, 2021 (5:32 PM) DWG. SCALE:NOTED DRAWN BY: ARMANDO CARDENAS RAUL RESIDENCE PROJECT INFORMATION: OWNER: ADDRESS: 53595 AVENIDA VALLEJO. LA QUINTA, CA 92253 CONTRACTOR SIGNATURE XWARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED PHOTOVOLTAIC "A/C" DISCONNECT TO BE LOCATED ON EXTERNAL A/C DISCONNECT A/C DISCONNECT TO BE PERMANENTLY MARKED AS FOLLOWS PHOTOVOLTAIC "D/C" DISCONNECT TO BE LOCATED ON EXTERNAL D/C DISCONNECT D/C DISCONNECT TO BE PERMANENTLY MARKED AS FOLLOWS WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Caution SOLAR ELECTRIC SYSTEM CONNECTED TO BE APPLIED TO THE INSIDE OR THE OUTSIDE OF THE MAIN ELECTRICAL PANEL Caution PHOTOVOLTAIC SYSTEM CIRCUIT BREAKER IS BACKFED TO BE PLACED AT DEDICATED CIRCUIT BREAKER (NEC 690.64(B)(4)(7)) WARNING DUAL POWER SUPPLY PHOTOVOLTAIC SYSTEM TO BE LOCATED ON EXTERIOR OF MAIN ELECTRICAL PANEL CAUTION: SOLAR P.V. CIRCUIT TO BE APPLIED TO ALL INTERIOR AND/OR EXTERIOR CONDUIT AND RACEWAYS EVERY 10 (TEN) FEET, AT TURNS AND ABOVE AND OR/BELOW ALL PENETRATIONS ELECTRIC SERVICE PANEL TO BE PERMANENTLY MARKED AS FOLLOWS SYSTEM CHARACTERISTICS SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: KW V DC V DC AMPS AMPS A/C SYSTEM CHARACTERISTICS SYSTEM VOLTAGE: MAXIMUM CURRENT: VOLTS AMPS WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE OVERCURRENT DEVICE AS PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT 2008 NEC 690.64(B)(7) TO BE LOCATED AT POINT OF INTERCONNECTION TO PLACED INSIDE DC DISCONNECT (NEC 690.53) #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED #12 TO BE LOCATED AT MAIN SERVICE PANEL #13 #14 480 7.15 380 9.33 15.0 240 26.25 ORANGE/BLACK RED/WHITE YELLOW/WHITE RED/WHITE ORANGE/BLACK RED/BLACK RED/BLACK ORANGE/BLACK ORANGE/BLACK BLACK/WHITE YELLOW/BLACK ORANGE/BLACK 06/04/2021 9;46, === == Ministry of Industry and Information entrusted the CTC tested the solar module samples randomly detected in Hainan basePOLY CRYSTALLINE MODULE IEC61215 / IEC61730 / IEC61701 / IEC62716 /IEC62804 INMETRO Anti-PID System voltage durability PPP 58042 Additional Environmental Tests Salt Mist Corrosion IEC 61701 Ammonia Corrosion IEC 62716 12 Years Manufacturing Warranty 12 Years 90% Power Output 25 Years 80% Power Output 100%5 0 12 18 25 97.5% 90% 80% Year 'JJKJ<GR[ K  , X U S  = G X X G T Z _ QUALIFICATIONS AND CERTIFICATES Strong mechanical load capacity Color classification Super strong frame Current division  IP68 junction box and connector have a high degree of waterproof, effectively resist the harsh environment; The junction box carries a current of 15A, ensuring high current flow through the modules; Glue-spilled tank has a double-layer waterproof, cross-section with hook-shaped aluminum frame, enhanced by 10% of the mechanical load strength; The module refines the current division, thus effectively reducing the loss Of up to 2% due to mismatch and increasing the power output of the system; Excellent salt spray resistance, anti-ammonia and anti PID, TUV, SUD certification approved; Passed the 2400pa wind load and 5400pa snow load test, ensuring that the module has a stable mechanical life; Modules are packaged according to color classification, to achieve consistent appearance after installation; SUNERGY USA WORKS LLC www.sunergyworks.com MECHANICAL DRAWINGS ELECTRICAL CHARACTERISTICS Maximum Power At STC(Pmax) Short Circuit Current(Isc) Open Circuit Voltage(Voc) Maximum Power Current(Impp) Maximum Power Voltage(Vmpp) Module Efficiency Power Tolerance TEMPERATURE CHARACTERISTICS I-V CURVES Norminal Operating Cell Temperature(Noct) Temperature Coefficient Of Pmax Temperature Coefficient Of Voc Temperature Coefficient Of Lsc ȭrȭ  ȭ  ȭ  ȭ PACKING CONFIGURATION Container Pieces Per Pallet Pallets Per Container Pieces Per Container ȑ-6    ȑ-6ȑ.7    SYSTEM INTEGRATION PARAMETERS Maximum System Voltage Maximum Series Fuse Increased Snowload Acc.to Iec 61215 Operating Temperature Number Of Bypass Diodes VDC 1000V 15A 5400Pa -40d+85ȭ 3 STC: 1000W/m2 irradiance, 25°C cell temperature, AM1.5. = ' < ' <  d = ' < ' <  d MECHANICAL SPECIFICATION Cell Type Number Of Cells Dimensions(AxBxC) Weights Front Glass Frame Junction Box Connector Output Cables Poly Crystalline 156.75x156.75mm 72č6x12Ď 1950x990x35mm 22.5kg 3.2mm Tempered Low Iron Glass Clear Anodized Aluminum Alloy Ip68,with Bypass Diodes Mc4 Compatible Tuv,±length 900mm,4.0mm² = ' < ' <  d NOCT Maximum Power At STC(Pmax) Short Circuit Current(Isc) Open Circuit Voltage(Voc) Maximum Power Current(Impp) Maximum Power Voltage(Vmpp) NOCT: Irradiance at 800W/m² , Ambient Temperature 20°C , wind speed 1m/s .                MOUNTING HOLES ,  䌙 ,,  GROUNDING HOLES  SIDE VIEWff FRONT VIEW ޜਨᶑ⸱䌙   ff, ,, f BACK VIEW  I-V Gurves at SUN325-72P at different Irradiances Cell Temp͹25ȭ CurrentͧAͨVoltage(V) Power voltage current curve at different temperature Normalizedlsc,Voc,Pmaxč%Ď)KRR:KSVKXGZ[XKȭ = ' < ' <  d = ' < ' <  d           SUNNY BOY 3.0-US / 3.8-US / 5.0-US / 6.0-US / 7.0-US / 7.7-US Power with a purpose The residential PV market is changing rapidly. Your bottom line matters more than ever—so we’ve designed a superior residential solution to help you decrease costs at every stage of your business operations. The Sunny Boy 3.0-US/3.8- US/5.0-US/6.0-US/7.0-US/7.7-US join the SMA lineup of field-proven solar technology backed by the world’s #1 service team. This improved residential solution features ShadeFix, SMA’s proprietary technology that optimizes system performance. ShadeFix also provides superior power production with a reduced component count versus competitors, which provides maximum reliability. No other optimized solution generates more power or is as easy as systems featuring SMA ShadeFix and SunSpec certified devices. Finally, SMA Smart Connected will automatically detect errors and initiate the repair and replacement process so that installers can reduce service calls and save time and money. Value-Added Improvements • SunSpec certified technology for cost-effective module-level shutdown • Advanced AFCI compliant to UL 1699B for arc fault protection Optimized Power Production • ShadeFix, SMA’s proprietary shade management solution, produces more power than alternatives • Reduced component count provides maximum system reliability Trouble-Free Service • SMA Service Mobile App provides simplified, expedited field service • Equipped with SMA Smart Connected, a proactive service solution that is integrated into Sunny Portal Reduced Labor • New Installation Assistant with direct access via smartphone minimizes time in the field • Advanced communication interface with fewer components creates 50% faster setup and commissioning SUNNY BOY 3.0-US / 3.8-US / 5.0-US / 6.0-US / 7.0-US / 7.7-US SB3.0-1SP-US-41 / SB3.8-1SP-US-41 / SB5.0-1SP-US-41 / SB6.0-1SP-US-41SB7.0-1SP-US-41 / SB7.7-1SP-US-41 / SB3.0-1TP-US-41 / SB3.8-1TP-US-41SB5.0-1TP-US-41 / SB6.0-1TP-US-41 / SB7.0-1TP-US-41 / SB7.7-1TP-US-41www.SMA-America.com *** Listed warranty terms are applicable in SMA-designated primary support countries, including the U.S., Canada, and Mexico. Reduced terms or restrictions may apply in other Americas regions and territories including the Pacific and Caribbean. Accessories External WLAN antennaEXTANT-US-40 SunSpec CertifiedRapid ShutdownReceivers Cellular Modem KitCELLMODKIT-US-10Revenue Grade Meter KitRGM05KIT-US-10 Technical data Sunny Boy 3.0-US Sunny Boy 3.8-US Sunny Boy 5.0-US 208 V 240 V 208 V 240 V 208 V 240 V Input (DC) Max. PV power 4800 Wp 6144 Wp 8000 Wp Max. DC voltage 600 V Rated MPP voltage range 155 - 480 V 195 - 480 V 220 – 480 V MPPT operating voltage range 100 – 550 V Min. DC voltage / start voltage 100 V / 125 V Max. operating input current per MPPT 10 A Max. short circuit current per MPPT 18 A Number of MPPT tracker / string per MPPT tracker 2/1 3 / 1 Output (AC) AC nominal power 3000 W 3000 W 3330 W 3840 W 5000 W 5000 W Max. AC apparent power 3000 VA 3000 VA 3330 VA 3840 VA 5000 VA 5000 VA Nominal voltage / adjustable 208 V / ●240 V / ●208 V / ●240 V / ●208 V / ●240 V / ● AC voltage range 183 – 229 V 211 – 264 V 183 – 229 V 211 – 264 V 183 – 229 V 211 – 264 V AC grid frequency 60 Hz / 50 Hz Max. output current 14.5 A 12.5 A 16.0 A 16.0 A 24.0 A 21.0 A Power factor (cos ϕ) / harmonics 1 / < 4 % Output phases / line connections 1 / 2 Efficiency Max. efficiency 97.2 %97.6 %97.3 %97.6 %97.3 %97.6 % CEC efficiency 96.0 %96.5 %96.5 %96.5 %96.5 %97.0 % Protection devices DC disconnect device / DC reverse polarity protection ● / ● Ground fault monitoring / Grid monitoring ● AC short circuit protection ● All-pole sensitive residual current monitoring unit (RCMU)● Arc fault circuit interrupter (AFCI)● Protection class / overvoltage category I / IV General data Dimensions (W / H / D) in mm (in)535 x 730 x 198 (21.1 x 28.5 x 7.8) Packaging dimensions (W / H / D) in mm (in)600 x 800 x 300 (23.6 x 31.5 x 11.8) Weight / packaging weight 26 kg (57 lb) / 30 kg (66 lb) Temperature range: operating / non-operating –25°C …+60°C / –40°C …+60°C Environmental protection rating NEMA 3R Noise emission (typical)39 dB(A) Internal power consumption at night < 5 W Topology / cooling concept transformerless / convection Features Ethernet ports 2 Secure Power Supply ●* Display (2 x 16 characters)● 2.4 GHz WLAN / External WLAN antenna ●/○ ShadeFix technology for string level optimization ● Cellular (4G / 3G) / Revenue Grade Meter ○/○** Warranty: 10 / 15 / 20 years ***●/○/○ Certificates and approvals UL 1741, UL 1741 SA incl. CA Rule 21 RSD, UL 1998, UL 1699B Ed. 1, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA V22.2 107.1-1, HECO Rule 14H, PV Rapid Shutdown System Equipment ● Standard features ○ Optional features — Not available NOTE: US inverters ship with gray lids. Data at nominal conditions * Not compatible with SunSpec shutdown devices **Standard in SBX.X-1TP-US-41 Type designation SB3.0-1SP-US-41 / SB3.0-1TP-US-41 SB3.8-1SP-US-41 / SB3.8-1TP-US-41 SB5.0-1SP-US-41 / SB5.0-1TP-US-41 POWER+ SOLUTION The SMA Power+ Solution combines legendary SMA inverter performance and SunSpec certified shutdown devices in one cost-effective, comprehensive package. In addition, SMA ShadeFix technology optimizes power production and provides greater reliability than alternatives. This rapid shutdown solution fulfills UL 1741, NEC 2014, and NEC 2017 requirements and is certified to the power line-based SunSpec Rapid Shutdown communication signal over DC wires, making it the most simple and cost-effective rapid shutdown solution on the market. Visit www.SMA-America.com for more information. Technical data Sunny Boy 6.0-US Sunny Boy 7.0-US Sunny Boy 7.7-US 208 V 240 V 208 V 240 V 208 V 240 V Input (DC) Max. PV power 9600 Wp 11200 Wp 12320 Wp Max. DC Voltage 600 V Rated MPP Voltage range 220 – 480 V 245 - 480 V 270 - 480 V MPPT operating voltage range 100 – 550 V Min. DC voltage / start voltage 100 V / 125 V Max. operating input current per MPPT 10 A Max. short circuit current per MPPT 18 A Number of MPPT tracker / string per MPPT tracker 3 / 1 Output (AC) AC nominal power 5200 W 6000 W 6660 W 7000 W 6660 W 7680 W Max. AC apparent power 5200 VA 6000 VA 6660 VA 7000 VA 6660 VA 7680 VA Nominal voltage / adjustable 208 V / ●240 V / ●208 V / ●240 V / ●208 V / ●240 V / ● AC voltage range 183 – 229 V 211 – 264 V 183 – 229 V 211 – 264 V 183 – 229 V 211 – 264 V AC grid frequency 60 Hz / 50 Hz Max. output current 25.0 A 25.0 A 32.0 A 29.2 A 32.0 A 32.0 A Power factor (cos ϕ) / harmonics 1 / < 4 % Output phases / line connections 1 / 2 Efficiency Max. efficiency 97.3 %97.7 %97.3 %97.9 %97.3 %97.5 % CEC efficiency 96.5 %97.0 %96.5 %97.0 %96.5 %97.0 % Protection devices DC disconnect device / DC reverse polarity protection ● / ● Ground fault monitoring / Grid monitoring ● AC short circuit protection ● All-pole sensitive residual current monitoring unit (RCMU)● Arc fault circuit interrupter (AFCI)● Protection class / overvoltage category I / IV General data Dimensions (W / H / D) in mm (in)535 x 730 x 198 (21.1 x 28.5 x 7.8) Packaging Dimensions (W / H / D) in mm (in)600 x 800 x 300 (23.6 x 31.5 x 11.8) Weight / packaging weight 26 kg (57 lb) / 30 kg (66 lb) Temperature range: operating / non-operating –25°C …+60°C / –40°C …+60°C Environmental protection rating NEMA 3R Noise emission (typical)39 dB(A)45 dB(A) Internal power consumption at night < 5 W Topology / cooling concept transformerless / convection transformerless / fan Features Ethernet ports 2 Secure Power Supply ●* Display (2 x 16 characters)● 2.4 GHz WLAN / External WLAN antenna ●/○ ShadeFix technology for string level optimization ● Cellular (4G / 3G) / Revenue Grade Meter ○/○** Warranty: 10 / 15 / 20 years ***●/○/○ Certificates and approvals UL 1741, UL 1741 SA incl. CA Rule 21 RSD, UL 1998, UL 1699B Ed. 1, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA V22.2 107.1-1, HECO Rule 14H, PV Rapid Shutdown System Equipment ● Standard features ○ Optional features — Not available NOTE: US inverters ship with gray lids. Data at nominal conditions * Not compatible with SunSpec shutdown devices **Standard in SBX.X-1TP-US-41 Type designation SB6.0-1SP-US-41 / SB6.0-1TP-US-41 SB7.0-1SP-US-41 / SB7.0-1TP-US-41 SB7.7-1SP-US-41 / SB7.7-1TP-US-41 Speed the completion of customer proposals and maximize the efficiency of your design team with the Sunny Boy-US series, which provides a new level of flexibility in system design by offering: » Hundreds of stringing configurations and multiple independent MPPTs » SMA’s proprietary ShadeFix technology optimizes power production » Diverse application options including on- and off-grid compatibility SBxx-US-DS-en-38 SMA and Sunny Boy are registered trademarks of SMA Solar Technology AG. Printed on FSC-certified paper. All products and services described as well as technical data are subject to change, even for reasons of country-specific deviations, at any time without notice. SMA assumes no liability for errors or omissions. For current information, see www.SMA-Solar.com.SMA wants to enable your sales team by arming them with an abundance of feature/ benefit support. Show your customers the value of the Sunny Boy-US series by utilizing: » The opportunity to join the SMA PowerUP network of installers who receive in-depth training, enhanced service, and prioritized marketing support » SMA’s 35 year history and status as the #1 global inverter manufacturer instills homeowners with peace of mind and the long-term security they demand from a PV investment » The most economical solution for shade mitigation with superior power production Ensure that your back office business operations run smoothly and succinctly while mitigating potential errors. The Sunny Boy-US series can help achieve cost savings in these areas by providing: » An integrated DC disconnect that simplifies equipment stocking and allows for a single inverter part number » All communications integrated into the inverter, eliminating the need to order additional equipment Expedite your operations in the field by taking advantage of the new Sunny Boy’s installer-friendly feature set including: » Direct access via smartphone and utilization of SMA’s Installation Assistant, which minimizes time/labor spent in the field and speeds the path to commissioning » Simple commissioning and monitoring setup in a single online portal » The fastest, easiest installation thanks to SMA ShadeFix and SunSpec certified shutdown devices SMA understands the factors that contribute to lifetime PV ownership cost, that’s why the Sunny Boy-US series was designed for maximum reliability and backstopped by an unmatched service offering. Benefit from: » SMA Smart Connected, a proactive service solution integrated into Sunny Portal that automatically detects errors and initiates the repair and replacement process » The SMA Service Mobile App, which provides simplified, expedited field service SIMPLE, FLEXIBLE DESIGN VALUE-DRIVEN SALES ENABLEMENT IMPROVED STOCKING AND ORDERING STREAMLINED INSTALLATION AND COMMISSIONING SUPERIOR SERVICE LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART & ASSEMBLY 10/26/2017 PRO SERIES BONDING CLAMPS REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A01PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET END CLAMP MID CLAMP 11 2 "11 16 " PRO SERIES END CLAMP PRO SERIES MID CLAMP END CAP INCLUDED WITH END CLAMP 11 16 " 17 16 " 1" 30mm to 51mm MODULE FRAME PART # TABLE P/N DESCRIPTION 302035M ENDCLAMP PRO 302030M MIDCLAMP PRO - MILL 302030D MIDCLAMP PRO - DRK LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART & ASSEMBLY 10/26/2017 BONDING TOP CLAMPS REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A01APRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION 302027C SM BND MIDCLAMP BC SS 302027D SM BND MIDCLAMP BC DRK SS 302028C SM BND MIDCLAMP EF SS 302028D SM BND MIDCLAMP EF DRK SS 302029C SM BND MIDCLAMP DK SS 302029D SM BND MIDCLAMP DK DRK SS FOR BONDING END CLAMP REFER TO SHEET SM-P05 MID CLAMP END CLAMP BONDING SM MID CLAMP BONDING SM END CLAMP 17 8 " 15 16" 1 4 " 11 2 " 13 16 " 1 8 " VARIES - REFER TO SHEET SM-P05 P1 4 " P5 16 " DETAIL B MID CLAMP TRIM CONNECTIONTRIM DETAIL A TRIM END CLIP A B LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART & ASSEMBLY 9/27/2017 SM TRIM END CLIP REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A02PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 1 15 16 " 3 1 16 " PART # TABLE P/N DESCRIPTION LENGTH 206072D-B SM TRIM DRK 168" 008025S SM TRIM END CLIP - TRIM MODULE FRAME END CLIP LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT KIT DETAIL 9/24/2018 FLASHKIT PRO REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A03PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. 2. PACKAGING: KITS OF 10 PART # TABLE P/N DESCRIPTION 004055M FLASHKIT PRO MILL 004055D FLASHKIT PRO DRK 8 1 16 " 2" 1 7 8 " 12" 3 8 "1 1 4 " 2 7 8 " 3 8 " HEX FLANGE NUT 3 8 "-16 X 1" SS SERRATED T-BOLT LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART & ASSEMBLY 11/19/2018 L-FOOT REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A11PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET SOLARMOUNT LIGHT ON L-FOOT SOLARMOUNT STANDARD ON L-FOOT SOLARMOUNT HD ON L-FOOT MAXIMUM HEIGHT MAXIMUM HEIGHT MAXIMUM HEIGHT MINIMUM HEIGHT MINIMUM HEIGHT 4 15 16 " 4 9 16 " 311 16 " 3 5 8 "4" L-FOOT 3 8 "-16 X 3 4 " T BOLT 3 8 "-16 FLANGE NUT 2" P3 8 " 213 16 " 17 8 " 5 16 " 213 16 "MINIMUM HEIGHT LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART & ASSEMBLY 9/27/2017 L-FOOT REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A04PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET SOLARMOUNT LIGHT ON L-FOOT L-FOOT 2"2" 3" 1 4 "Ø3 8 " 3 8 "-16 X 3 4 " T BOLT 3 8 "-16 FLANGE NUT PART # TABLE P/N DESCRIPTION 304001C L-FOOT SERR W/T-BOLT CLR 304001D L-FOOT SERR W/T-BOLT DRK NOTES: 1. L-FOOT CAN BE INSTALLED IN TWO ORIENTATIONS, PLEASE REFER TO INSTRUCTIONS IN THE QUICK START GUIDE. 2 7 16 "MINIMUM HEIGHT 3 11 16 "MAXIMUM HEIGHT SOLARMOUNT STANDARD ON L-FOOT SOLARMOUNT HD ON L-FOOT 4 1 2 " 4 7 8 " 3 11 16 "3 5 16 " MAXIMUM HEIGHT MAXIMUM HEIGHT MINIMUM HEIGHT MINIMUM HEIGHT LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART & ASSEMBLY 9/27/2017 BONDING SPLICE BAR REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A05PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET BONDING SPLICE BAR 4" 1 1 2 " 15 16 " TYPICAL SPLICE BAR DETAIL TYPICAL EXPANSION JOINT DETAIL 1 2 " #12 X 3 4 " SELF DRILLING SS SCREWS INCLUDED NOTE THAT ONLY 2 SCREWS ARE USED AT AN EXPANSION JOINT. THE SPLICE BAR DOES NOT BOND ACROSS AN EXPANSION JOINT. SEE INSTALLATION GUIDE FOR INSTRUCTION. PART # TABLE P/N DESCRIPTION 303018C BND SPLICE BAR SERRATED CLR 303018D BND SPLICE BAR SERRATED DRK DETAIL A FRONT L-FOOT HINGE DETAIL B REAR TILT LEG A B LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT TILT ASSEMBLY 9/27/2017 LOW PROFILE TILT REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A07PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET NOTES: 1. SEE SM TiH INSTALLATION GUIDE FOR ASSEMBLY INSTRUCTIONS. DETAIL A L FOOT DETAIL B REAR TILT LEG A B LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT TILT ASSEMBLY 9/27/2017 HIGH PROFILE TILT REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A08PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET NOTES: 1. SEE SM TiH INSTALLATION GUIDE FOR ASSEMBLY INSTRUCTIONS. LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT TILT ASSEMBLY 9/27/2017 ADJUSTABLE TILT LEG REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A09PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 1 5 8 " STRUT LENGTHS SQUARE TUBE LENGTHS 1 13 16 " 1 16 " 1" Ø3 8" 1" Ø3 8 " 1 16 " TILT LEG TABLE P/N DESCRIPTION TOTAL ADJUSTABLE LENGTHS SQUARE TUBE STRUT 307107M SM ADJ TILT LEG, 8"-12", W/HDW 8" to 12" 8" 8" 307115M SM ADJ TILT LEG, 18"-30", W/HDW 18" to 30" 18" 18" 307120M SM ADJ TILT LEG, 26"-44", W/HDW 26" to 44" 26" 26" 307134M SM ADJ TILT LEG, 40"-72", W/HDW 40" to 72" 40" 40" ADJUSTABLE LENGTHS 3 8 "-16 SS FLANGE NUT 3 8 "-16 x 3" SS HEX BOLT 3 8 " x 11 2 " x 1 8 " HD FENDER WASHER L-FEET NOT INLCUDED IN TILT LEG KITS 3 8 "-16 x 11 4 " SS HEX BOLT 3 8 " x 1 1 2 " x 1 8 " HD FENDER WASHER 3 8 "-16 STRUT NUT DETAIL A A LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT HD PART & ASSEMBLY 9/27/2017 BOTTOM CLIP REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-A10PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 1"1" 1 1 4 " BOTTOM CLIP PART # TABLE P/N DESCRIPTION 302000C SMHD BOTTOM CLIPS W/HDW CLR 1 4 "-20 X 3 4 "SSHEXHEADBOLT 1 4 " FLAT WASHER 1 4 "-20 SS FLANGE NUT LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DETAIL 9/11/2017 STANDARD RAIL REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-P01PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 2 9 16 " 1 4 " BOLT LOCATION 3 8 " BOLT LOCATION PART # TABLE P/N DESCRIPTION LENGTH 320132M SM RAIL 132" MILL 132" 310132C SM RAIL 132" CLR 132" 320168M SM RAIL 168" MILL 168" 310168C SM RAIL 168" CLR 168" 320168D SM RAIL 168" DRK 168" 320208M SM RAIL 208" MILL 208" 310208C SM RAIL 208" CLR 208" 320240M SM RAIL 240" MILL 240" 310240C SM RAIL 240" CLR 240" 310240D SM RAIL 240" DRK 240" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DETAIL 9/11/2017 LIGHT RAIL REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-P02PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION LENGTH 315168M SM LIGHT RAIL 168" MILL 168" 315168D SM LIGHT RAIL 168" DRK 168" 315240M SM LIGHT RAIL 240" MILL 240" 315240D SM LIGHT RAIL 240" DRK 240" 1 11 16 " 1 4 " BOLT LOCATION 3 8 " BOLT LOCATION LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DETAIL 9/11/2017 HD RAIL REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-P03PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 3" 1 7 8 " 3 8 " BOLT LOCATION BOTTOM CLIP SLOT 1 4 " BOLT LOCATION PART # TABLE P/N DESCRIPTION LENGTH 410144M SMHD, RAIL 144" MILL 144" 410168M SMHD, RAIL 168" MILL 168" 410204M SMHD, RAIL 204" MILL 204" 410240M SMHD, RAIL 240" MILL 240" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DETAIL 9/27/2017 END CAPS REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-P04PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET SOLARMOUNT STANDARD RAIL SOLARMOUNT LIGHT RAIL 15 16 " 27 8 " 3 4 " END CAP OPTIONAL BREAK/CUT LINE PUSH IN FRICTION FIT NOTES: 1. END CAP INCLUDED WITH EVERY END CLAMP. 2. END CAP FITS SOLARMOUNT LIGHT AND STANDARD RAIL PROFILES. B CLAMP 30mm to 32mm Module Thickness (1.18" to 1.26")C CLAMP 33mm to 36mm Module Thickness (1.30" to 1.42") D CLAMP 38mm to 40mm Module Thickness (1.50" to 1.57") E CLAMP 50mm to 51mm Module Thickness (1.97" to 2.00")F CLAMP 45mm to 47mm Module Thickness (1.77" to 1.85") K CLAMP 39mm to 41mm Module Thickness (1.54" to 1.61") TYPICAL END CLAMP DETAILS LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DETAIL 9/27/2017 END CLAMPS - TOP MOUNTING REVISION DATE: DRAWING TYPE: DESCRIPTION:SM-P05PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 1 5 16 " 2 1 16 " 1 19 32 "1 7 16 " 1 13 16 "1 5 8 " 1 4 "Ø 1 1 2 " 3 16 " PART # TABLE P/N DESCRIPTION 302021C SM ENDCLAMP B CLR AL 302021D SM ENDCLAMP B DRK AL 302022C SM ENDCLAMP C CLR AL 302022D SM ENDCLAMP C DRK AL 302023C SM ENDCLAMP D CLR AL 302023D SM ENDCLAMP D DRK AL 303024C SM ENDCLAMP E CLR AL 302024D SM ENDCLAMP E DRK AL 302025C SM ENDCLAMP F CLR AL 302025D SM ENDCLAMP F DRK AL 302026C SM ENDCLAMP K CLR AL 302026D SM ENDCLAMP K DRK AL