06-2905 (AR) Title 24`°,' TITLE 24 REPORT
CITY OF LA QU1NI .
BUILDING & SAFETY
FOR CONSTRUCTION
Title 24 Report for:
4 Castells Residence oA
55575 Medalist
La Quinta, CA
Project Designer:
,Report Prepared By:
Joan D. Hacker
Insu-form, Inc.
41-921 Beacon Hill, Suite A
Palm Desert, CA 92211
(760) 779-0657
Job Number:
• D AUG 012pp6
Date:
7/31/2006 eY
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.1 by EnergySoft Job Number. User Number: 2655
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 7
HVAC System Heating and Cooling Loads Summary 9
Room Load Summary 10
•
r
Certificate Of Compliance:
Residential
❑ Existing + Add/Alt
(Part 1 of 4) CF -1 R
aSfPlls Residpnre
Project Title
Mcrialict I
()Minta
Natural Gas
Slab on Grade Area:
7/31/2006
Date
S'i97-9 a
Project Address
Building Permit #
Inti i Inc
(760) 779-0657
-form
Documentation Author
Telephone
Plan Check/Date
FnArgyPro
15
Field Check/Date
CompliNgce Method
Climate Zone
TDV Energy Use
Standard
Proposed Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
3.40
3.11
0.29
Space Cooling
119.43
103.24
16.20
Fans
17.66
15.24
2.43
Domestic Hot Water
8.73
8.73
0.00
Pumps
0.00
0.00
0.00
Totals
149.23
130.32
18.91
Building Type:
Standard:
[-X] Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
12.7%
❑ Addition
Total Conditioned Floor Area:
❑ Existing + Add/Alt
Existing Floor Area:
(E) 90 deg
Raised Floor Area:
Natural Gas
Slab on Grade Area:
Fenestration: Average Ceiling Height:
Area: 590 ft 2 Avg. U: 0.87 Number of Dwelling Units:
Ratio: 17.9% Avg. SHGC: 0.70 Number of Stories: '
BUILDING ZONE INFORMATION # of Thermostat
Zone Name Floor Area Volume Units Zone Type Type
IZone 929n 32,E 1 On Conditioned Rpthack
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Wall Wnnd 192 n n74 R-19 R-0 0 An An
Wall Wood 108 a n74 R_19 R_n n 180 P
Wall Wood 100 n_074 CLQ R-0_0 270 _9Q
Rnnf Wood 220 0 025 R_38 R-0 0 _0 n
Wall Wood 224 Q 102 R_13 R_0 0 gd-9f1
nnnr None 24 1.450 None R-0.0 An gn
Wall Wnnd 300 n 109 R_13 R-0 0 An gn
Wall Wnnd 403 Q102 R_13 R-0 0 _d An
Wall Wood 268 0 102 X13 R_0 0 270 _q f)
Wall Wood 310 _p102 R-13 R-0.0 180 An
Rnnf Wnnd 3 070 Q 049 R_19 R-0 0 An n
3,290 ft2
n/a ft2
0 ft2
3,290 ft2
9.9 ft
1.00
Vent
Hgt. Area
—nla
Gains Condition
Y / N Status JA IV Reference Location / Comments
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:3 of 10 1
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Castells Residence 7/31/2006
Project Title Date
FENESTRATION SURFACES
Area Thick. Heat Inside
(so (in.) Cap. Cond. R -Val.
JA IV Reference
Condition
Status
Location/
Comments
PERIMETER LOSSES
Insulation
True Cond.
Location/
#
Type
Overhang
Area U -Factor' SHGCZ
Azm. Tilt Stat. Glazing Type
Comments
J-
Window
Front
(E) 1080 0 870 NERC -010 MERG An _g0_ Fxicting nnuhle Mtl Uncoated Default
Addition
REA. Dist. Len. Hgt. Dist. Len. Hgt.
2
Window
Left
(S) 12.0 0.870 NFRC 0_70 NFRC
180 .90 Existing Double Mtl Uncoated Default
Addition
3
Window
Front
(E) 108.0 0.870 NFRC 0_70 NFRC
90 90 Removed Double Mtl Uncoated Default
Living
Zone
4
Window
Front
(E) 40.0 0.870 NFRC 0_70 NFRC
90 90 Existing Double Mtl Uncoated Default
Living
Zone
5
Window
Front
(E) 12.0 0.870 NFRC 0_70 NFRC
90 90 Removed Double Mtl Uncoated Default
Living
Zone
6
Window
Front
(E) 12.0 0.870 NFRQ0 70 NFRC
90 90 Existing Double Mtl Uncoated Default
Living
Zone
L
Window
Right
(N) 12.0 0.870 NFRQ 0.70 NFRC 0 90 Existing Double Mtl Uncoated Default
Living
Zone
8
Window
Right
(N) 8.0 0.870 NFRC 0_70 NFRC
0 90 Existing Double Mtl Uncoated Default
Living
Zone
6
Window
Bight
(N) 6.8 0.870 NFRQ 0.70 NFRC 0 90 Existing Double Mtl Uncoated Default
Living
Zone
1Q
Window
Right
(N) 30.0 0.870 NFRC 0.70 NFRC 0 90 Existing Double Mtl Uncoated Default
Living
Zone
1
Window
Right
(N) 40.0 0.870 NFRC 0.70 NFRC
0 90 Existing Double Mtl Uncoated Default
Living
Zone
12
Window
Rear
(W) 45.0 0.870 NFRC 0_70 NFRC
270 90 Existing Double Mtl Uncoated Default
Living
Zone
Aa
Window
Rear
CN) 120.0 0.870 NFRC J1.70 NFRC 270 c0_ Existing Double Mtl Uncoated Default
Living
7pne
14
Window
Rear
on 66.7 0.870 NFRC 0_70 NFRC
270 90 Existing Double Mtl Uncoated Default
Living
Zone
15
Window
Left
(S) 90.0 0.870 NFRC 0_70 NFRC
180 90 Existing Double Mtl Uncoated Default
Living
Zone
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING
Area Thick. Heat Inside
(so (in.) Cap. Cond. R -Val.
JA IV Reference
Condition
Status
Location/
Comments
PERIMETER LOSSES
Insulation
Condition
Window
Type
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt. LExt.
REA. Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug
Screen
0.76
9.0
12.0
2.0
0.1 2.0
2.0
2
Bug
Screen
0.76
4.0
3.0
2.0
0.1 2.0
2.0
3
Bug
Screen
0.76
9.0
12.0
2.0
0.1 2.0
2.0
4
Bug
Screen
0.76
4.0
10.0
2.0
0.1 2.0
2.0
5
Bug
Screen
0.76
4.0
3.0
2.0
0.1 2.0
2.0
6
Bug
Screen
0.76
2.0
6.0
2.0
0.1 2.0.
2.0
7
Bug
Screen
0.76
2.0
6.0
2.0
0.1 2.0
2.0
8
Bug
Screen
0.76
2.0
4.0
2.0
0.1 2.0
2.0
9
Buq
Screen
0.76
4.5
1.5
2.0
0.1 2.0
2.0
10
Bug
Screen
0.76
5.0
6.0
2.0
0.1 2.0
2.0
11
Bug
Screen
0.76
6.8
6.0
2.0
0.1 2.0
2.0
12
Bug
Screen
0.76
5.0
3.0
2.0
0.1 2.0
2.0
13
Bug
Screen
0.76
6.8
6.0
2.0
0.1 2.0
2.0
14
Bug
Screen
0.76
6.8
10.0
2.0
0.1 2.0
2.0
15
Bug
Screen
0.76
4.0
2.0
2.0
0.1 2.0
2.0
THERMAL MASS FOR HIGH MASS DESIGN
Type
Area Thick. Heat Inside
(so (in.) Cap. Cond. R -Val.
JA IV Reference
Condition
Status
Location/
Comments
PERIMETER LOSSES
Insulation
Condition
Location/
Type
Length
R -Val. Location
JA IV Reference
Status
Comments
Slab Perimeter
18
None No Insulation
26-A1
New
Addition
Slab Perimeter
90
None No Insulation
26-A1
Existing
Living Zone
Run Initiation Time: 07/31/06 17:33:04 Run Code: 1164392384
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:4 of 10
WATER HEATING SYSTEMS Ratedl Tank Energy Standbyl Tank Insul.
Water Heater # in Input Cap. Condition Factor Loss R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext.
Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing. 0.53n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
A
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
ZEMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Joan D. Hacker
Title/Firm: Title/Firm: Insu-form, Inc.
Address: Address:. 41-921 Beacon Hill, Suite A
Palm Desert: CA 92211
Telephone: Telephone: .(760) 779-0657
Lic. #:
(signature) (date) (si natur (date)
Enforcement Agency
Name:
Title/Firm:
Address: `
Telephone:
(signature/stamp) (date)
Run Inatoatoon Time* 07/31/06 17:33:04 Run Codes 154392384
Ener Pro 4.1 by Ener Soft User Number: 2655 Job Number: Page: 5 of 10
- Certificate Of
Compliance :'Residential
(Part 3 of 4)
CF -1 R
Castells Residence
7/31/2006,
Project Title
Date
HVAC SYSTEMS
Heating
Minimum
Cooling
Minimum Condition
Thermostat
Location
Type
Eff
Type
Eff - Status
Type
Livinq Zone
Central Furnace
60% AFUE
Split Air Conditioner
12.0 SEER Existinq
Setback
'
a
HVAC DISTRIBUTION
Duct
Duct Condition
Ducts
Location
Heating
Cooling
Location
R -Value Status
Tested?
Living Zone
Ducted
Ducted
Attic
4.2 . Existing
No
Hydronic Piping
Pipe Pipe
InsuL,
System Name
Length Diameter
Thick.
WATER HEATING SYSTEMS Ratedl Tank Energy Standbyl Tank Insul.
Water Heater # in Input Cap. Condition Factor Loss R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext.
Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing. 0.53n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
A
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
ZEMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Joan D. Hacker
Title/Firm: Title/Firm: Insu-form, Inc.
Address: Address:. 41-921 Beacon Hill, Suite A
Palm Desert: CA 92211
Telephone: Telephone: .(760) 779-0657
Lic. #:
(signature) (date) (si natur (date)
Enforcement Agency
Name:
Title/Firm:
Address: `
Telephone:
(signature/stamp) (date)
Run Inatoatoon Time* 07/31/06 17:33:04 Run Codes 154392384
Ener Pro 4.1 by Ener Soft User Number: 2655 Job Number: Page: 5 of 10
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
Castells Residence 7/31/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
aaencv determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the
rdequacy of the special justification and documentation submitted. Plan I Field
The Existing Water Heater "Standard Gas 50 gal or Less" has an EF less than the Table R3-11 CEC Default Vintage Values.
The HVAC Svstem "Existing" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement.
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF4R Plan Field
installation certificate.
Run do Time: 07/31106 7.33.0 un Code: 115439 384
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:6 of 10
-Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked'with an asterisk (7 below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. NIA DESIGNER MENT
Building Envelope Measures
§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑x
❑
§ 150(b): Loose fill insulation manufacturers labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑ .
❑X
❑
apply to exterior mass walls).
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
❑
❑x
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
❑x
❑
b. outside air intake with damper and control, flue damper and control
❑
❑x
❑
2. No continuous burning gas pilot lights allowed.
❑
Q
❑
§ 1W ft Air retarding wrap installed to comply wit§ 151 meets requirements specified in the ACM Residential Manual.
❑
❑X
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 permfinch.
❑
❑
❑
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and
ElElinclude
❑X
❑
CF -6R Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
❑
❑
❑
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑x
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient infiltration
❑
❑x
❑
(SHGC), and certification.
Page:7 of 10
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑x
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑X
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑X
❑.
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
❑
❑X
❑
insulation having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑x
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150 -AB or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑x
❑ '
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source
❑
❑X
❑
and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment
❑
❑X
❑
maintenance, and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systemstcollectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number:
Page:7 of 10
Mandatory Measures Summary:. Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
Instructions: Check or initial applicable boxes when completed or check N/A if not
ENFORCE -
DESCRIPTION
applicable.
N/A DESIGNER MENT•
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
,
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,
❑ X❑ ❑
605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of
R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑ X❑ ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑ ® ❑
duct tapes unless such tape is used in combination with mastic and draw bands.
0 ® ❑
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
El ® 11
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ ® ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
4'
❑ ® ❑
7. Flexible ducts cannot have porous inner cores.
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§' 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ® ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (1): Cool Roof material meets specified criteria
❑ ❑ El
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ X❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined❑
X❑ ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ X❑ ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ X❑ ❑
controlled by an occupant sensor that complies with Section i19(d) that does not tum on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ a ' ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ X❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). "
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ' ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number:
Page:8 of 10
11HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Castells Residence 7/31/2006
SYSTEM NAME FLOOR AREA
Living Zone 3,290
Number of Systems
2
Heating System
Output per System
70,000
Total Output (Btuh)
140,000
Output (Btuh/sqft)
42.6
Cooling System
Output per System
58,000
Total Output (Btuh)
116,000
Total Output (Tons)
9.7
Total Output (Btuh/sqft)
35.3
Total Output (sgft/Ton)
340.3
Air System
CFM per System
2,210
Airflow (cfm)
4,420
Airflow (cfm/sqft)
1.34
Airflow (cfm/Ton)
457.2
Outside Air (%)
0.0
Outside Air (cfm/sqft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
CFM
I Sensible
6,291
66,904
4,988
1,885
53,813
0
11,901
6,904
0
0
0
0
0
0
0
0
0
11,901
6,904
90.7051 4,9881
67 622
Existing 70,804 40,973 140,000
Total Adjusted System Output 70,804 40,973 140,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 prn Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0°F 68.5°F 68.5°F 98.3°F
'' Supply Air Ducts
Outside Air
0 cfm Supply Fan Heating Coil 96'8 °F
4420 cfm ROOMS
70.0 OF
68.5 °F
TOOLING SYSTEM PSYCHROMETRICS (Airstream T
11.0/77.6°F 80.5/69.5°F 80.5/69.6°F
Outside Air * "
n cfm
11 1 80.5/69.5 OF
% Return Air Ducts 4
65.5/64.6°F
Supply Fan Cooling Coil
4420 cfm
h Return Air Ducts 1
Supply Air Ducts
68.0 / 65.4 OF
63.3% R.H. ROOMS
78.0/68.8°F
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:9 of 10 1
ROOM LOAD SUMMARY
PROJECT NAME
Castells Residence
DATE
7/31/2006
SYSTEM NAME
Living Zone
FLOOR AREA
3,290
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Addition
Addition
1
1 255
13,347
1,027
1,255
13,347
1,027
265
7,561
Living Zone
Existing Living
1
5,036
53,557
3,962
5,036
53,557
3,962
1,620
46,252
PAGE TOTAL 1 6,291 66,904 4,988 1,885 53,813
TOTAL 1 6,291 66,904 4,988 1,885 53,813
EnergyPro By EnergySoft User Number: User Job Number: Page:10 of 10
R F STRUCTURAL CONSULTANTS; INC.
---------
75'153 MERLE DRIVE, STE. B, PALM DESERT, CA 92211
• r: PHONE (760) 836-1000; .
.FAX(76b)836-0856
E-MAIL. R. FRANGIE@VERIZON.NET
July 25, 2005
Construction is NOT PERMITTFD
' . on the following Code' Holiday_ s: .
Scott's Construction Services
- 55-575 Medallist
New Year's Day F -
La Quinta, Ca. 92253'
s ,
Dr. Martin Luther ung 1r. Day
ry .
Attn.: Scott Carter,
President's Day
Memorial Day
Re.: The Castells Residence remodel
' .. Independence Day ;
55-575 Medallist
Labor Day _
La Quinta, Ca. 92253 ' '
r Veteran's Day
Job no.. 3000
•Thanks0ving Day
Subject: Patio Enclosure -
r ,
Christmas Day a '
Dear Scott
=,
• In regard of the above mentioned project and as per our conversation on July 23, 2006 we submit'
the following:
^
Follow the attached partial framing and foundation plans and details "A", "B", and: "C" for the
enclosure of the patio at the front of the great room
If you.have any questions please do not hesitate to contact our office'
CITY OF LA QUINTA
Zeyad Faqih P.E..DEFT.
SAFETY
f BUILDING&
' - APPROVE®
. O
a-1Nsno
FOR CONSTRU TION
'
WUBECHARGED IFTHE APPRovED
PIANS AND JOB CARD ARE NOT ON
.'DA1M-:AW0L6
t
THE SITE FOR SCHEDUL
r
, .
ON.
NO
. , , :. •
pFE SISI q
C®rT$'i'RTjCTI OSS
i No 57958
October 1st - April 30
M t 7.00 a.m. to 5:30 p.m.
o
to 5:00 P.m-
` ' - : y Exp. 06-30-0
.. ,-
s' 61
Saturday ;UO a.m.
V\
o` ..t':}•
Sunday: None
Government Code Holidays: Non®
'9 F ,
A
', 1... .
OF (,
"AN FARC 041
May 1st -September 30th
ADEQUA
`
Monday -Friday: 6:00 a.m. to 7:00 p.m.
8:00 a:m. to 5:00 P -m-
IS REQUIRED J1 Q B, SITE DURING ,
A V Q S
Saturday:
Sunday: + None
Government Code Holidays: None
PHASES OF C Rfi ll
EMPTIED ASN SSARY. FAILURE TO D s
MAY CAUSE TH ;
►
DUMPED AT THE EXPENSE OF THE OWNER/ ;
- - . '•
CONTRACTOR." . .. .
FLAN I-
3,070 SQ_ FT.
2 !BEDkOc MS, 2-1/2 BATHS Wart C;ASITA
THIS EXQUISITR DBION INCTAIL)E3 DIRECT ACCESS TO THE COURTYARD AND POOL FROM. THE MASTER SUITE
AND MASTER SArii. A BREAKFAST NOOK IS t: A7URV.n IN THE KITCHEN. Ti4Is PLAN ALSO
INCLUDE-1; A SPACIOUS cASITA WITH A FULL BATH AND WALK-IN Clkl3ET.
2 -0
( L(v rN 5P19CL
D
p G 12006 - - - • ' u
;o{c, np . - ,• J •r° • _ , ! ys - • •r S:i11• ' . I .-r . v- '' ' != , t
By ^ • ,`'• '. ;,.C,;., 't Via' '.!`- :,\;, :^ # . l-r : ' _:r;' YM,• -: r l-'. l Op,;• .. _ _ -'•-.r , ;-. . ., : ..: ;
N Q PILDING T.
FOR CON.-FiI C.TIC i
' DATE BY
ni
. di# 'rr • -.i r ..,\ •i , __. _ "'- ` .r ,q :,' i•: y .^ .Y ,` . +f .r,1 • : .-I ' I '•`l. Vi•
tSUM ..i "'• fv_ ' .' ! It .I.({Y' I
16+jIczr ..4 • . . ! ,.. i . • .!' ?r ! i ! )r`rt . .t - +. r
MASMM i
r _ _`-, • ,ter, , !
J 6A#+1LB 1 'r ., ._ ,^' + :. Y •F1 - aY9rA r:
t y :70..'"'), . ^, •'it Y' .,` . :' ••: : f '•''w
t _
YSD2
CASTELLS RESIDENCE- - -
f PATIO ENCLOSURE..., .
a.
r •
i 5.5575 MEDALLIST
LW. 14 ,'.
4
SD2
LA QU I MITA, CA. ;
Xy.
Q:L=4'—S'
14
O AROUND +, ca
—
itiJO 'OPENING E)'
PSL
R. BM.
rykJO.
'N 10
._.
x8 DR. M.
10
E)
EXISTING
.
—2x6
`
STUp
2=2x6
TRIM•
04
CN
iss.
00
Cc
. 4
+...
.
- i - R
,. 1 XI
•
X
- W
•
W~EXISTING
l ..
Ali,'
SD2
C
cc
17 BLW
h .
•
SD2 .+ nr
(
10
,
}l.
18
1 A.
CD
SD2
ABV,
SD
[
18 X'o
HI, TO `LOW
'
.
SD2 S 2 `
_
ROOF
R"
TSO+
10
10
-
T
W/MST48
— —
6x6
"
Y
HDR
C"
XL B
_ rov1TA
BU
1 ING.& SAFETY DEPT.
App. ED
V
:OR CONSTiSUCTION •
• <
SD2
- O
*
- ,
' I
Q
` r , _
... ! A-G) X-1 1. .
N
Z
W
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APROVED-
.-.. , FOR:CONSTRUCTI0r4'I
. 'DATE BY
}
1- WEEP SCREED AT
EXTERIOR PLASTER ONLY
2- EXTERIOR FINISH
-----'
3- 2X STI.IDS Q 16" O.C.
4
3
4- INTERIOR FINISH,
S- 2X P.T. D. F. SILL WITH
8 S
1
5/.9" DIA. X 12" ANCHOR
BOLTS Q 72" O.C. AND
12' MAX. FROM ENDS OF
MUD SILL (U.N.O. ON PLANS)
2"x2"x3/16" WASHER SHALL -
FINISH
io
BE USED
°
a
GRADE
6- UNDERLAYMENTAND
4
VAPOR BARRIER PER
SOILS REPORT
4
\\
_
7- #4 REBAR CONTINUOUS `
NATURAL
'TOP AND BOTTOM
6
°
' GRADE
8- CONCRETE SLAB
iv
Z9-
DASHED ALTERNATIVE
7
D
41'r
-MIN. 6 -MIL VISQUEEN TO
MIN. '12".WELDED LAP
3HAVE
CLR.
AT ALL SEAMS (U.N.O.)
911
12°
U.N.O.
EXTERIOR
BEARING
FOOTING
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APROVED-
.-.. , FOR:CONSTRUCTI0r4'I
. 'DATE BY
0
Z I- EXISTING FOOTING
LL
2- 12" LONG #4 DOWELS AT 18" O.C.
W/ SIMPSON "SET' EPDXY 6" INTO
EXISTING CONC. INSTALL PER
ICBO ER -5272 W/ SPECIAL AINSPECTION
REQUIREMENT
3- CONTINUOUS FOOTING W/ (1) #4
TOP & BOTTOM
B FOUNDATION DETAIL
CITY OF LA QUINT
BUILDING & SAFETY T.
DER
FOR
NSTRUCTION
DATE 13Y
r
r
1- FACE OF STUDS
2- CONCRETE PORCH SLAB
3- CONCRETE SLAB
A UNDERLAYMENTAND
VAPOR BARRIER PER `
SOILS REPORT
5- #4 REBAR CONTINUOUS
TOP AND BOTTOM
(U.N.O.)
6- #3 X 24" DOWELS
24" O.C.
-MIN. 6 -MIL VISQUEEN TO
HAVE MIN. 12" WELDED LAP
AT ALL SEAMS (U.N.O.)
12
U.N.O.
C HOUSE TO PORCH
CITY OF LA QUIN A
BUILDING & SAFETY
APPROVE®
FOR CONSTRUCTION
i. DATE EiY
Scots ry',sf. 5e.-u;cc5 'CASTEL:LS
RESIDENCE'
--J6-0 6 ! 5 7k- O 5 l q. PATIO ENCLOSURE
55575 MEDALLIST
LA QU 1NTA, CA.
too
LT/,ze4 t er.c, '+
o vor UK,} (TGSO
PON
iG lln 0 e-XS '''^ I g IV ,• tJ WC SGI't.CC ►
#All cow 54;.%+, to-, s4 g 11 cc) aej,>e 14e- ul OF LA QUI
, _DING & SAFE NTA
wm, ft,e. 2001 C-4/46em„- e 5 5 r, PPR
ISU;IJ ) I IVe eaSe0 a d4leG4ghtG'*l, Z4 X FOR CON
STR E®
2W$ ,,, u v pA ON
L= y Od es .J l oC < B'—
codo 4 <) 0.e:t.,faces.
. S 0r
l
INSULA ON CERTIFICATE
This is to certify that insulation has been installed in conformance with the current energy
regulation, Caiifornia Administrative Code, Title 24, State of California, In the building at
66 -575 -MEDALLIST DRIVE LUT 10, LA QUINTA CA
-QE
I rNGS:
TYPE: BATTS MAUNFACTURER: Certainteed THICKNESS: R-38
WALLS:
TYPE:ATTS MANUFACTURER: Certain -teed THICKNESS: R-19
GENERAL CONTRACTOR: EFii;•rJNE CO BUILDERS LICENSE #
TITLE:
PARAGON SCHMID BUILDING RODUCTS AM
ASCO Company LICENSE # 221517
eBY: TITLE: ACCOUNT REPRESENTIVE DATE:
INI ULATIM d%1=oilL-i9 TE
i is to certify that insulation has been installed In conformance_..- '"
regulatQ0,, Calitrnia Administrative Code, Title 24, State of Galifor th t ren y
\, s n the building located at
CEIL-- INGS:
TYKE: BAITS M FACTURER; rtainteed THICKNESS: R-38
WALLS:
TYPE: BATTS MA FACTURER: Ce
eed THICKNESS: R -t9
GENERAL CONTR OK: EHLldd(i" C® BUILt7ERS
LICENSE
BY
-___ , TITLE:
PARAGO SCHMID BUILDING PRODUCTS A MASCO Company LICENS 1517
BY: TITLE: ACCOUNT REPRESENTIVE DATE:
.•.. ... ... a/• JJI. is J.. J•..aa a. .. N'..ih.. ...• ... .. /r.L'n 'rY x . a J. r ..
FtalFLl t' 1.7.I gLA7 riTlnW^1CZ KnPtIN-11 C