Loading...
12-1040 (RER) Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT:,, Residence Remodel 75-591 Talking Rock. CITy. 0 La Quinta CA 92253 F LA QUINTA, BUILDING. & SAFETY DEPT. APPROVED, Project Designer: FOR CONSTRUCTION Mike Perryman 75-591 Talking Rock DA rE 10 Zq 17- BY La Quinta, CA 92553 (310)500 -8553 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, - 77-085 Michigan Drive Palm Desert, Ca 92211 OCTA247012, BY. Job Number - Date: 10/18/2012'' The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developedby EnergySoft, LLC — www.energysoft.com. Ener Pro 5.1 by EnergySoft User Number 6712 RunCode: 2012-10-187I3:28:56 ID: Ll A .- +, j � .y � � ., - ; j � .y � � ., - ; • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11011812012 Date Project Address 75-591 Talking Rock La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 6,800 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 2,500 Existing Wall Wood Framed R-11 3,051 Existing Wall Wood Framed R-13 1,080 Altered Door Opaque Door None 32 Existing Slab Unheated Slab -on -Grade None 6,800 Perim = 480' Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 32.0 0.550 0.67 none none None Existing Skylight 24.0 0.550 0.67 none none None Existing Front (NE) 134.0 1.190 0.83 none none Bug Screen Existing Front (E) 104.0 1.190 0.83 none none Bug Screen Existing Left (SE) 303.0 1.190 0.83 none none Bug Screen Existing Left (S) 64.0 1.190 0.83 none none Bug Screen Existing Rear (SVV) 63.0 1.190 0.83 none none Bug Screen Existing Rear (SVIO 140.0 0.550 0.46 none none Bug Screen New Rear (SVt9 140.0 1.190 0.83 none none Bug Screen Removed Rear (Ko 176.0 1.190 0.83 none none Bug Screen Existing Rear (M 140.0 0.550 0.46 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 4 Central Furnace 80% AFUE Split Air Conditioner .9.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC- Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-10-18T13:28:56 ID: Page 3 of 14 r� L • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11011812012 Date Project Address 75-591 Talking Rock La Quinta California'Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 6,800 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Rear (tom 140.0 1.190 0.83 none none Bug Screen Removed Right (NtM 229.2 1.190 0.83 none none Bug Screen Existing Right (N) 104.0 1.190 0.83 none none Bug Screen Existing Right (N) 140.0 0.550 0.46 none none Bug Screen New Right (N) 140.0 1.190. 0.83 none none Bug Screen Removed HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by EnergySoft User Number 6712 RunCode: 2012-10-187'13:28:56 /D: Page 4 of 14 • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Remodel Building Type ® Single Family ❑ Addition Alone ❑Multi Family m Existing+ Addition/Alteration8/2012 7Da/,,,Residence SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification,,and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2012-10-18713:28:56 ID: Pa ge 5 of 14 • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Residence Remodel ❑ Multi Family m Existing+ Addition/Alteration 10/18/201 ANNUAL ENERGY USE SUMMARY . Standard Proposed Margin TDV kBtu/ft2 r Space Heating 10.77 9.15 1.62 Space Cooling 203.98 190.53 13.45 Farts 32.64 30.41 2.23 Domestic Hot Water 5.29 5.29 0.00 Pumps 0.00 0.00 0.00 Totals 252.68 235.38 17.30 Percent Better Than Standard: 6.8 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 30 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 1,240 238 Fuel Available at Site: Natural Gas (SE) 1,340 367 Raised Floor Area: 0 (SK9 2,060 519 Slab on Grade Area: 6,800 (NKK 1,120 473 Average Ceiling Height: 14.0 Roof 2,556 56 Fenestration . Average U -Factor: 1.02 TOTAL: 1,653 Average SHGC: 0.73 Fenestration/CFA Ratio: 24.3% REMARKS .Traditions Country Club . STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, /18 oi, Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set ,of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with,any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Mike Perryman Address 75-591 Talking Rock Name Mike Perryman City/State/zip La Quint;, CA 92553 Phone (310) 500-8553 Signed License # Date EnerqvPro 5.1 by Ener.QvSdft User Number: 6712 RunCode: 2012-10-18713:28:56 /D: Page 6 of 14 W] CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1&1812012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation . Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status - 4 Location/Comments Roof 2,500 0.049 R-19 0 '0 Existing 4.2.1-A4 Residence Wall 826 0.110 R-11 30 90 Existing 4.3.1-A2 + Residence Wall 176 0.110 R-11 75 _ 90 Existing 4.3.1-A2 Residence Wall 657 _0.110 R-11 120 90 Existing 4.3.1-A2 - Residence Wall 316 0.110 R-11 165 90 Existing 4.3.1-A2 Residence ' Wall. 757 0.110 R-11 210 90 Existing - 4.3.1-A2 Residence Wall 360 0.102 R-13' 210 90 Altered 4.3.1-A3 (E=4.3.1 -A2) Residence Wall 64 0.110 R-11 255 90 Existing 4.3.1-A2 Residence Wall 360 0.102 R-13 255 90 Altered 4.3.1-A3 E=4.3.1 -A2 Residence Wall 219 0.110 R-11 300 90 Existing 4.3.1-A2 Residence Door 32 0.500 None 300 90 Existing 4.5.1-A4 Residence Wall 36 0.110 R-11 345 90 Existing 4.3.1-A2 Residence Wall 360 0.102 R-13 345 90 Altered 4.3.1-A3 E=4.3. I-A2j Residence Slab 6,800 0.730 None 0 180 Existing 4.4.7-A1 Residence FENESTRATION SURFACE DETAILS ' ID Type Area LI -Factor' SHGC - Azm Status Glazing Type Location/Comments 1 Skylight 32.0 0.550 1 Default 0.67 Default 0 Existing Double Non Metal Clear Residence 2 Skylight 24.0 • 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear Residence 3 Window 20.0 1.190 Default 0.83 Default 30 Existin Sin le Metal Clear Residence 4 Window 20.0 1.190 Default 0.83 Default ' 30 Existing Single Metal Clear Residence 5 ' Window 25.0 1.190 Default 0.83 Default 30 Existing Single Metal Clear Residence 6 Window 20.0 1.190 Default. 0.83 Default 30 Existing Single Metal Clear Residence 7 Window 9.0 1.190 Default 0.83 Default 30 Existing Single Metal Clear Residence 8 Window 40.0 1.190 Default 0.83 Default 30 Existing Single Metal Clear Residence 9 Window 40.0 1.190 Default 0.83 Default 75 Existing Single Metal Clear' Residence 10 Window 64.0 1.190 Default 0.83 Default 75 Existing Single Metal Clear Residence 11 Window 64.0 1.190 Default. 0.83 Default 120 Existing Single Metal Clear Residence 12 Window 36.0. , 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence 13 • Window 9.0 1.190 Default .0.83 Default 120 Existing Single Metal Clear Residence 14 Window 9.0 1.190 Default .0.83 Default 120 Existing Single Metal Clear Residence 15 Window 48.0 1.190 Default 0.83 Default 1120 Existing Single Metal Clear Residence 16 Window 48.0 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS - . .. ' ID Exterior Shade Type SHGC- Window ' H t Wd Ove hang Left Fin Len H t LExt RffxF Dist . Len Right Fin H t Dist Len H t 1 None 1.00 2 None 1.00 . 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 , 6 Bug Screen 0.76 7 Bug Screen - 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 -Bug Screen 0.76 15 IBug Screen' 0.76 16 18ug Screen 0.76 s Ener Pro 5.1 by Ener Sof User Number: 6712. Run Code: 2012-10-18713:28:56 ID, Page 7 of 14 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 10/18/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor -C-a-V-it-YTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 36.0 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence 18 Window 1.0 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence 19 Window 1.0 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence 20 Window 1.0 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence 21 Window 1.0 1.190 Default 6.83 Default 120 Existing Single Metal Clear Residence 22 Window 9.0 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence 23 Window 40.0 1.190 Default 0.83 Default 120 Existing Single Metal Clear Residence 24 Window 64.0 1.190 Default 0.83 Default 165 Existing Single Metal Clear Residence 25 Window 63.0 1.190 Default 0.83 Default 210 Existing Single Metal Clear Residence 26 Window 105.0 0.550 NFRC 0.46 NFRC 210 New Dual non Metal Tint Residence 27 Window 35.0 0.550 NFRC 0.46 NFRC 210 New Dual non Metal Tint Residence 28 Window 105.0 1.190 Default 0.83 Default 210 Removed Single Metal Clear Residence 29 Window 35.0 1.190 Default 0.83 Default 210 Removed Single Metal Clear Residence 30 Window 48.0 1.190 Default 0.83 Default 255 Existing Single Metal Clear Residence 31 Window 105.0 0.550 NFRC 0.46 NFRC 255 New Dual non Metal Tint Residence 32 Window 35.01 0.550 NFRC 0.46 NFRC 255 New Dual non Metal Tint Residence (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B =Default Table from Standards, NFRC =Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht in Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bu4 Screen 6.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 JBug Screen 0.76 EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-10-18T13:28:56 ID: Page 8 of 14 • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 11011812012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Window 64.0 1.190 Default 0.83 1 Default 255 Existing Single Metal Clear Residence 34 Window 64.0 1.190 Default 0.83 Default 255 Existing Single Metal Clear Residence 35 Window 105.0 1.190 Default 0.83 Default 255 Removed Single Metal Clear Residence 36 Window 35.0 1.190 Default 0.83 Default 255 Removed Single Metal Clear Residence 37 Window 64.0 1.190 Default 0.83 Default 300 Existing Single Metal Clear Residence 38 Window 64.0 1.190 Default 0.83 Default 300 Existing Single Metal Clear Residence 39 Window 40.0 1.190 Default 0.83 Default 300 Existing Single Metal Clear Residence 40 Window 6.0 1.190 Default 0.83 Default 300 Existing Single Metal Clear Residence 41 Window 6.0 1.190 Default 0.83 Default 300 Existing Single Metal Clear Residence 42 Window 40.2 1.190 Default 0.83 Default 300 Existing Single Metal Clear Residence 43 Window 9.0 1.190 Default 0.83 Default 300 Existing Single Metal Clear Residence 44 Window 40.0 1.190 Default 0.83 Default 345 Existing Single Metal Clear Residence 45 Window 105.0 0.550 NFRC 0.46 NFRC 345 New Dual non Metal Tint Residence 46 Window 35.0 0.550 NFRC 0.46 NFRC 345 New Dual non Metal Tint Residence 47 Window 64.0 1.190 Default 0.83 Default 345 Existing Single Metal Clear Residence 48 Window 105.0 1.190 Default 0.83 Default 345 Removed Single Metal Clear Residence (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Len H t LExt RExt Dist Left Fin Right Fin Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number. 6712 RunCode: 2012-10-18713:28:56 ID: Page 9 of 14 • C] 0 • • •- '. • Projectr. Residence Remodel Single Family ■ Addition Alone Multi Family 10 Existing+ Add ition/Alte ration OPAQUE SURFACE DETAILS W-11 ivill-li�� -----joint Appendix 4 Location/Comments FENESTRATION0 �Emm 0 MI: PRIM Single Metal Clear . ... E Fri dil .- Exterior Shade Type • • • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Residence Remodel Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 110/18/2012 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area ft Existing Altered Removed Volume Year Built HVAC- Residence 6,800 95,200 1989 Totals 1 01 6,8001 01 0 HVAC SYSTEMS ' System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 4 Central Furnace 80% AFUE Split Air Conditioner 9.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Ot . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard 50 gal or Less 1 Small Gas All Pipes Ins 40,000 50 0.57 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 a y Q c System Name Pipe Length Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried Ener Pro 5.1 by EnergySoft User Number: 6712 Run Code: 201 2-10-1 8 713:28:56 ID: Pae 11 of 14 t. MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Residence Remodel Date 110/18/2012 j_ t. MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Residence Remodel Date 110/18/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD; or CF= 1 R -ALT Form) shall supersede the' items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance. specifications whether, they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). Exterior doors and windows are weather-stripped; •all joints and penetrations are caulked and sealed. _117: 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool, Roof is s ecified on the CF -1 R Form.' *§1 50 a : Minimum R-19 insulation'in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design Ialieled.R-Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor: §150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14"or 16. '§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or facto -built fire laces have a closable metal or glass door C'oveririq the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. ' §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor.air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets andallother regulated appliances are certified by the Energy Commission. "§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5: .-§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances ; (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. " 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. §1500): Heatinq systems are equipped with thermostats that meet the setback re uirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. • '`` §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatina sections of hot water pipes are insulated per Standards Table.150-13. ' §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot -water tank shall be insulated to Table 150 -Band Equation -150-A. ' §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table -123-A. 150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. -§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating slstems and/or collectors are certified by the Solar Ratin and Certification Corporation. , EnergyPro 5,1 by EnergySoft User Number: 6712 RunCode: 2012-10-18713:28:56 ID: Page 12 of 14 � s , -MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date " Residence Remodel 11011812012 .§150(m)1: All air -distribution system ducts and plenums'installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- -4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the ;applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. 1150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar,heatin . 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 :Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . -Residential Lighting Measures: -•§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies ,contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps•rated 13 Watts or greater shall be electronic and shall have an output frequency no less than • 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be ratted to consume no more than five watts of power as determined by. §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral exhaust fans, in rooms other than kitchens, shall'meet the applicable requirements of §150(k). -to 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant _ sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed -luminaries in garages; laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a `manual -on occupant sensor.* =§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by En ergySoft User Number. 6712 RunCode: 2012-10-18T13:28:56 ,, ID: Page 13 of 14 0 �4 0 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Residence Remodel 11011812012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. .EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square.feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the .same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that -they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, Nand one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply,with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and.carports with a'total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ,dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-10-18713:28:56 /D: Page 14 of 14