Loading...
BSOL2023-1098DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar BSOL2023-1098 59315 ALMERIA 764691067 $38,000.00 Declaration / Acknowledgement BUILDING PERMIT Ottigta CALIFORNIA Owner: John Vander Lans PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 12/15/2023 ISSUED DATE: 01/02/2024 Applicant: Zeke Alvarez 117 N SUNNYSIDE AVE, CLOVIS, CA 93611 Contractor: Zeke Alvarez / 938313 117 N SUNNYSIDE AVE, CLOVIS, CA 93611 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 1/2/24 9:55 pm Page 1 of 3 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2023-1098 Property Address: 59315 ALMERIA Use of Permit 16.15kW SOLAR ARRAY - (38) 425W HANWHA Q.TRON BLK M-G2+ PANELS W/ SOLAREDGE SE11400H-US W/ S440 POWER OPTIMIZERS [760SF] 2022 CALIFORNIA BUILDING CODES. Construction Details PV System Type PV Miscellaneous Equipment EA Residential 0 System Size (kW DC) 16.15 PV Strings (EA) 3 Valuation Details Group Financial Information Invoice No. Fee INV-00003307 Permit Issuance Technology Enhancement Fee Building Standards Administration Digital Archiving and Records Management Fee - OTC Solar (PV) More than 10kW PC Solar (PV) More than 10kW Total for Invoice INV-00003307 Fee Amount $115.94 $8.00 $1.52 $12.00 $45.77 $45.77 $229.00 Amount Paid $115.94 $8.00 $1.52 $12.00 $45.77 $45.77 $229.00 Grand Total for Permit $229.00 $229.00 Workflow / Inspections Workflow Step / Action Name Application Completeness Check v.1 Submittal Document Verification v.1 Action Type Plan Check v.1 Building Review (1 Day) v.1 Start Date End Date 12/15/2023 9:50 12/15/2023 9:50 Generic Action 12/15/2023 9:50 12/15/2023 0:00 12/27/2023 13:59 Receive Submittal 12/15/2023 0:00 12/27/2023 13:59 Permit Issuance v.1 12/27/2023 14:00 01/02/2024 13:55 Verify Contractor info & Conditions have been met v.1 Generic Action 12/27/2023 14:00 Verify & Invoice Fees v.1 Generic Action 12/27/2023 14:00 Verify Fee Payment & Issue Permit v.1 Generic Action 01/02/2024 13:55 Print, Attach, and Email Building Permit v.1 Create Report 01/02/2024 13:55 01/02/2024 13:55 Solar Inspections v.1 Rough Electrical v.1 Inspection Temp Use of Permanent Power v.1 Inspection Inspections - Final v.1 Solar Final v.1 Inspection Printed: 1/2/24 9:55 pm Page 2 of 3 BUILDING PERMIT Permit Type: Permit Number: Property Address: Solar BSOL2023-1098 59315 ALMERIA Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 1/2/24 9:55 pm Page 3 of 3 CONSTRUCTION HOURS October 1st - April 30 Monday - Friday: 7:00 a.m. to 5:30 p.m. Saturday : 8:00 a.m. to 5:00 p.m. Sunday : None Government Code Holidays: None May 1st - September 30th Monday - Friday: 6:00 a.m. to 7:00 p.m. Saturday : 8:00 a.m. to 5:00 p.m. Sunday : None Government Code Holidays: None BSOL2023-1098 16.15kW SOLAR ARRAY - (38) 425W HANWHA Q.TRON BLK M-G2+ PANELS W/ SOLAREDGE SE11400H-US W/ S440 POWER OPTIMIZERS [760SF] 2022 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 12/27/2023 BY IF THE VANDER LANS RESIDENCE 59315 ALMERIA, LA QUINTA, CA 92253 11.400 kW (AC) AND 16.150 kW (DC) PHOTOVOLTAIC SYSTEM Construction is NOT PERMITTED in the following Code Holidays: New Year's Day Dr. Martin Luther King Jr. Day President's Day Memorial Day Independence Day Labor Day Veteran's Day Thanksgiving Day Christmas "AN ADEQUATELY SIZED DEBRIS CONTAINER IS REQUIRED ON THE JOB SITE DURING ALL PHASES OF CONSTRUCTION AND MUST BE EMPTIED AS NECESSARY. FAILURE TO DO SO MAY CAUSE THE CITY TO HAVE THE CONTAINER DUMPED AT THE EXPENSE OF THE OWNER / CONTRACTOR." Signed: 12/14/2023 COVER SHEET PLANET SOLAR 73820 DINAH SHORE DRIVE PALM DESERT, CA, 92211 LIC# 938313, CLASS B, C10 760.341.1413 ZEKE©PLANETSOLAR.COM SIGNED: DATE: 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: SQ.FT c-1 1 MODULE DIM: 67.8" X 44.6" MODULE WEIGHT: 47.2 I bs NUMBER OF STORIES: 01 STRUCTURE TYPE: SFR NUMBER OF ROOFS UTILIZED: 04 ROOF FRAMING: 2" X 4" ROOF TRUSSES: 24" 0.C. SPACING INVERTER (38 PV MODULES): (02)STRINGS OF (13) MODULES (13) WITH POWER OPTIMIZERS (01)STRING OF (12) MODULES (12) WITH POWER OPTIMIZERS Structural On ly �` 4U Y til e, 2 3 I."C 88783 m F��o F Ca FIRE CLEARANCES ADHERED AS PER SECTION R324.6 OF 2022 CRC 3'-0" FROM EDGE 1'-6" FROM RIDGE 1'-6" FROM VALLEYS I VICINITY MAP (N)JUNCTION BOX ON ROOF * do* (N)PV ARRAY ON ROOF (N)PV MODULES WITH POWER OPTIMIZERS PHOTOVOLTAIC INSTALLATION PLAN SCALE: 1 "=20' (N) INVERTER (INSIDE GARAGE) 3/4" EMT CONDUIT ON ROOF/UNDER EAVE /IN ATTIC ROOF ACCESS AS PER SECTION R324.6 OF 2022 CRC (E) MAIN SERVICE PANEL AND UTILITY METER (OUTSIDE) (N) AC UTILITY DISCONNECT SWITCH (OUTSIDE) CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 12/27/2023 BY J F NEW CONSTRUCTION SCOPE OF WORK THIS PROJECT CONSISTS OF THE INSTALLATION OF (38) PHOTOVOLTAIC MODULES WITH (38) POWER OPTIMIZERS AND (01) UTILITY INTERACTIVE INVERTER. PV MODULES WILL BE MOUNTED TO AN EXISTING COMPOSITE UNDER ARRAYS/EXISTING CEMENT S-TILE AROUND ARRAYS ROOFTOP USING IRONRIDGE ATTACHMENTS AND IRONRIDGE RAIL. THE ATTACHMENT SYSTEM IS SPECIFICALLY DESIGNED TO WITHSTAND 130MPH WIND LOADS AND SEISMIC LOADS ON EXISTING ROOFTOPS. REFER TO CODE COMPLIANT INSTALLATION MANUAL FOR DETAILED INFORMATION AND WATER PROOFING SPECIFICATIONS. SHEET INDEX SHEET NO. INDEX NO. DESCRIPTION: 01 C-1 COVER SHEET 02 T-1 TITLE SHEET 03 M-1 PHOTOVOLTAIC EQUIPMENT PLAN 04 E-1 SINGLE LINE DIAGRAM 05 D-1 PHOTOVOLTAIC MODULE DATA SHEET 06 D-2 INVERTER DATA SHEET 07 D-3 OPTIMIZER DATA SHEET 08 D-4 ATTACHMENT DATA SHEET 09 D-5 RAIL DATA SHEET 10 L-1 WARNING PLACARDS PROJECT JURISDICTION PREPARED FOR: CITY OF COUNTY: ADDRESS: CITY, STATE,ZIP PH: CITY OF LA QUINTA 78495 CALLE TAMPICO, LA QUINTA, CA 92253 760-777-7012 CODE COMPLIANCE ALL WORK SHALL CONFORM TO ALL PERTINENT CODES, REGULATIONS, LAWS, AND ORDINANCES AS REQUIRED BY STATE OF CALIFORNIA. 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA FIRE CODE PV SYSTEM SPECIFICATIONS HANWHA Q.TRON BLK M-G2+ SERIES 425W 38 SOLAREDGE SE11400H-US HD -WAVE INVERTER(240V) S440 POWER OPTIMIZERS 01 38 IRONRIDGE QM-LM-01 ATTACHMENTS IRONRIDGE XR100 RAIL 18° 151 ° 241 ° 61° 16.150kW MODULE QTY. INVERTER OTY. RACKING TILT AZIMUTH DC POWER RATING (STC) TITLE SHEET w U z w V) 0 Lf) N Q (NI 0) �wQ Z Q J Q wiz z z LC) O > w PLANET SOLAR 73820 DINAH SHORE DI PALM DESERT, CA, 922 LIC# 938313, CLASS B, 760.341.1413 ZEKE©PLANETSOLAR.COI SIGNED: 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: SQ.FT 2 T-1 3/8" HARDWARE L—BRACKET— T.O. M FROM ROOF SURFACE 5" M N. 3" MIN MODULE CLAMP SOLAR MODULE MOUNTING RAIL COMPOSITE' SHEATING 5/16" x 3-1/2" LAG SCREW 2.5" MIN EMBEDMENT DEPTH SS BOLT AND FLANGE NUT FLASHING SEALANT APPLIED BELOW AND TOP 2" X 4" TRUSSES PV ATTACHED W/IRONRIDGE ATTACHMENTS AND IRONRIDGE RAIL SYSTEM. REFER TO DATA SHEETS FOR WIND AND VERTICAL FORCE DESIGN CHARACTERISTICS 18° COMPOSITE UNDER ARRAYS 2X4 TRUSSES @ 24" 0.C. RIDGE BOARD 9'-0" FROM EAVE TO GROUND CEMENT S—TILE AROUND ARRAY PANELS TO BE MOUNTED NO MORE THAN 10 INCHES 3' 0" OVERHANG MAXIMUM FROM ROOF SURFACE ATTACHMENT SPACING 72"OC CONNECTION DETAIL N.T.S. SECTION PLAN N.T.S. AERIAL VIEW ROOF LOAD CALCULATION ROOF: 38 PANELS PV AREA SINGLE MODULE: 20.99 SQ. FT. PV AREA TOTAL: 797.62 SQ. FT. PV PANEL WEIGHT = 47.2 Ibs MOUNTING HARDWARE WEIGHT=10 Ibs/panel ENTIRE WEIGHT ON ROOF: (47.2 Ibs, panels)x(38)+ (1.5 Ibs, optimizers)x(38)+ (10 Ibs, structure)x(38)=2,230.6 Ibs [1,793.6+57+380] 2,230.6 Ibs/797.62 sq.ft.= 2.79 Ibs/sqft 10 n GBL GROUNDING PER 2022 CEC 690.43, UL 2703 LISTED NEW CONSTRUCTION /1-18' 8" -1'-6 \1\\\\\\\\\ 0 0 0 D D ATTACH MODULES TO STRUCTURE PER DETAILS AND DATA SHEET 0 I II FIRE CLEARANCES ADHERED AS PER SECTION R324.6 OF 2022 CRC 3'—O" FROM EDGE 1'-6" FROM RIDGE 1'-6" FROM VALLEYS EXISTING 2"X4" TRUSSES @ 24" O.C. 0 0 1' a 1 0 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE12/27/2023 BY �F (N)PV ARRAY ON ROOF 0 \\\\\\\\\\\\\ \ 1, (N)PANEL RAILS 29' 11" (N)PV MODULES WITH POWER OPTIMIZERS P 0 (N) INVERTER (INSIDE GARAGE) (N)JUNCTION BOX ON ROOF (N) AC UTILITY DISCONNECT SWITCH (OUTSIDE) 3/4" EMT CONDUIT ON ROOF/UNDER EAVE /IN ATTIC (E) MAIN SERVICE PANEL AND UTILITY METER (OUTSIDE) !0 CLASS 1 — DIVISION 1 METALLIC CONDUIT W/NO JOINTS OUTSIDE (E) MAIN SERVICE PANEL AND UTILITY MET1R 'L (N) AC UTILITY DISCONNECT SWITCH (N) JUNCTION BOX ON ROOF INSIDE GARAGE (N) INVERTER J TO ARRAYS GRADE PV EQUIPMENT PLAN w U z w r7 o Ln 05 _ N w <CC LJJ z Z U J QQ J Q CC z om� Z �n o > w MAIN SERVICE ELEVATION GENERAL NOTES: 1. CONDUIT RUNS ARE DIAGRAMMATIC_ SUBJECT TO FIELD CONDITIONS AND INSTALLATION CONTRACTOR'S FINAL LOCATIONS THAT MEET NEC REQUIREMENTS. 2. ALL EQUIPMENT INSTALLED SHALL BE IN ACCORDANCE WITH ALL LOCAL BUILDING AND ELECTRICAL CODES. 3. THIS SYSTEM HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITH STAND 130 MPH WIND —LOADS. REFER TO RACKING DATASHEET. 4. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND UNDERSTANDING THE SECTION OF THE INVERTERS OPERATION AND MAINTENANCE MANUAL THAT PERTAINS TO THE SAFETY AND PROPER INSTALLATION. 5. THE SYSTEM SHALL NOT BE INTERCONNECTED UNTIL APPROVAL FROM LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. 6. ALL CONDUCTORS TO BE COPPER UNLESS SPECIFIED OTHERWISE. 7. THE SOLAR PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 8. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHT RESISTANT. 9. THIS IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES PV LAYOUT PLAN SCALE: 1 "=15' PLANET SOLAR 73820 DINAH SHORE DRIVE PALM DESERT, CA, 92211 LIC# 938313, CLASS B, C10 760.341.1413 ZEKE©PLANETSOLAR.COM SIGNED: DATE: 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING:---- SQ.FT M-1 3 MODULES 00 (3) #6 EGC J BOX (1) #6 EGC GENERAL NOTES: 1. IF SERVICE PANELS DO NOT HAVE EXISTING GROUNDING ELECTRODE, IT IS THE CONTRACTORS RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 2. #6 BARE COPPER GROUND TO BE ATTACHED TO EACH MODULE DIRECTLY VIA GROUND LUGS AND ATTACHED TO EACH RAIL WITH LUGS 3. EACH SOLAR MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE PER THE MANUFACTURER'S INSTRUCTIONS. N)PV INVERTER (1) #6 EGC (N) AC DISCONNECT BOND TO CHASSIS (TYP. (1) #6 EGC (N) ATTACH NEW GEC TO EXISTING BY IRREVERSIBLE MEANS (E) SERVICE PANEL BOND TO CHASSIS (TYP.) I I I 4-' PV ARRAY INFORMATION Module Wattage Number of Modules VALUE 425W 38 Module (VOC) 38.67V Module (VMP) 32.98V Module (ISC) 13.49A Module (IMP) 12.88A Max Voc of Inverter 480V DESCRIPTION Input Total Input Input Input Short Input data from PV Module data sheet Modules for PV system data from PV Module data sheet data from PV Module data sheet data from PV Module data sheet circuit data from PV Module data sheet data from Inverter data sheet 41° Average high temperature °F 6° Record low temperature "F Modules per String 13,12 Number of String 2,1 Branch VOC 502.71 V Module string configuration Module string configuration Module Voc x Number of Modules per Branch Branch VMP 428.74V Module Vmp x Number of Modules per Branch Branch ISC 40.47A Module Isc x Number of Branches OVERALL SYSTEM AMPRE 47.5A max output inverter GROUNDING DETAIL PV SYSTEM VALUES MODULES TO INVERTERS TOTAL PV SYSTEM RATING = (MODULE WATTS) X (# OF MODULES IN ARRAY) MAX PV SYSTEM VOLTAGE = (VOC VOLTS) X (# OF MODULES) X CEC FACTOR MAX CIRCUIT CURRENT = CEC FACTOR X (TOTAL SYSTEM WATT/ TOTAL SYSTEM VOLT) (3) #10 USE-2 - POSITIVE (3) #10 USE-2 - NEGATIVE (3) #6 COPPER (GND) (3) 3/4" EMT CONDUIT PV ARRAYS WITH POWER OPTIMIZERS 00 / (2 STRINGS OF 13) MODULES WITH (13) POWER OPTIMIZERS (1) STRING OF (12) MODULES WITH (12 POWER OPTIMIZERS 1 • • • • • • HEM • • • SINGLE LINE WIRING DIAGRAM SCALE: N.T.S. SYSTEM CALCULATIONS (INVERTER "A") STRING: (425Wdc X 13 MODULES) =5,525 Wdc (38.67 Vdc X 13 MODULES ) = 502.71 Vdc -> voltage limited by solaredge optimizer, complies 1.25 X (5,525Wdc/502.71 Vdc)= 13.73 Adc X 3 STRINGS=41.19 Adc = LOAD TO INVERTER < 45A, system complies SYSTEM: 11,400 Wac 240V 1.25 x 47.5Aac MAX OUTPUT INVERTER= 59.375Aac 38 MODULES X 425Wdc =16,150 Wdc -> LESS THAN 17,650 Wdc SYSTEM COMPLIES WIRE CHART #10AWG 090C = 40A x temp deration #6AWG 090C = 75A x temp deration of Signed. D< 12/23 DC INTERCONNECTION CIRCUIT (3) #10 THWN-2 - POSITIVE (3) #10 THWN-2 - NEGATIVE (1) #6 THWN-2 (GND) (1) 3/4" EMT CONDUIT J-BOX NEC 310.15(B)(3)(A) ACTUAL of 80% for 4 conductors = 32A > 13.73A, system complies 80% for 4 conductors 60A > 59.375A, system complies MAXIMUM NUMBER OF MODULE IN STRING: 13 OPERATING CURRENT: OPERATING VOLTAGE: MAXIMUM SYSTEM VOLTAGE: MAXIMUM SHORT-CIRCUIT CURRENT: 47.5A 400V 480V 59.375A (N)SOLAREDGE HD -WAVE SE11400H-US (240V) INVERTER (INSIDE GARAGE) DC - A 45A MAX 47.5A HHTCarn1ED DC DISCONNECT GENERAL NOTES 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL CONDUCTORS TO BE COPPER UNLESS NOTED OTHERWISE. 3. INTERMODULE WIRING-DURASHEATH LOW -VOLTAGE POWER, UNSHIELDED, EPR, HYP, VOLTS: 600VDC, U.L. TYPE RHH/RHW-2/USE-2 CONDUCTOR SIZE (AWG/KEMIL) 10, RATED AT 90' WET OR DRY WITH MULTI -CONTACT LOCKABLE CONNECTORS 4. ANY DC WIRING RUNS IN THE INTERIOR OF THE HOME SHALL BE RUN IN A METAL CONDUIT OR RACEWAY AND CLEARLY MARKED "CAUTION DC -CIRCUIT" EVERY 5 FEET PER CODE REQUIREMENTS. 5. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. 6. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE PV CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 7. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALUC WATER PIPING. IT IS THE CONTRACTORS RESPONSIBILITY TO INSTALL A NEW SUPPLEMENTAL GROUNDING ELECTRODE. 8. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER NEC 110.3(B) 9. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH TERMINALS - terminals ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION." 10. LABEL "PHOTOVOLTAIC UTILITY INTERACTIVE INVERTER" AND "WARNING POTENTIAL ARC FLASH HAZARD CAN CAUSE: SHOCK, BURN, OR DEATH." 11. LABEL "PV SYSTEM UTILITY DISCONNECT SWITCH" SWITCH COVER TO BE LOCKED AT ALL TIMES. SWITCH TO BE VISIBLE BLADE AND ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22 12. LABEL BREAKER "PHOTOVOLTAIC ELECTRIC POWER SOURCE" PER NEC 705.10 AND "BREAKERS ARE BACKFED" PER NEC 690.64(B)(5) 13. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 14. LABEL "CAUTION" SOLAR CIRCUIT SHALL BE ON ALL EXPOSED CONDUIT, ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES AND ALL AC CONDUIT ON MICRO -INVERTER SYSTEMS. 15. SEE DERATING PLACARD AND "LOAD CALCS TO BE FIELD VERIFIED BY INSPECTOR AT FIRST INSPECTION" 16. PV CONNECTION IN PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION. PV SYSTEM BOM ITEM: DESCRIPTION: QTY. PHOTOVOLTAIC MODULES: HANWHA Q.TRON 425W MODEL: Q.TRON BLK M-G2+ SERIES 425W 38 POWER OPTIMIZERS, S440, SOLAREDGE 38 JUNCTION BOX NEMA 3R 1 INVERTER: SOLAREDGE SE11400H-US HD -WAVE INVERTER 1 sze O O 60A AC UTILITY DISCONNECT SWITCH, 240V SOLAR READY 400A SPLIT MAIN SERVICE PANEL 200A / 200A BUSS AND MCB'S SYSTEM GROUND 1 1 1 PV SINGLE LINE BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY COMPANY 1 RESERVED 0 RESERVED 0 RESERVED 0 (E)SOLAR READY 400A SPLIT MAIN SERVICE PANEL 200A / 200A BUSS AND MCB'S 0 (OUTSIDE) (E)UTILITY METER 120/240VAC DEDICATED PV SOLAR PORT, 200A ALLOWABLE (N) 60A PV (N)60A AC UTILITY DISCONNECT SWITCH NEMA-3R, 240V (OUTSIDE) (1) 3/4" EMT CONDUIT (3) #6 THWN-2 (1) #6 THWN-2 (GND) (1) 3/4" EMT CONDUIT (3) #6 THWN-2 (1) #6 THWN-2 (GND) M (E) LOADS (E) 200A MCB 7 (E) 200A1 MCB i (E) LOADS /\ / \ CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 12/27/2023 BY I F 85°-90° C TEMP (185° 9 Size AGW or MCIN AMPERES 14 25 12 30 10 40 S 55 6 75 4 95 2 125 1 145 1/0 190 2/0 215 3/0 250 W 0 0NO] 0 0 Q O 0 Q JO N In < _ I- w 0 wMz (Jr)ZV)r) < 0WCO7-J I- CDO C w o a1 Z N w Jr0 < (.00 W 0-NO_JNNI w H- 0 W z 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING:---- SQ.FT [-1 4 Q.TRON BLK M-G2+ SERIES 410-430Wp 1108Cells 22.4% Maximum Module Efficiency MODEL Q.TRON BLK M-G21 The ideal solution for: Rooftop arrays on [1 residential buildings MODULE DATA SHEET SCALE: N.T.S. a.ANTUM High performance Qcells N-type NM solar cells Warranty OCEAN LaJ E 21635 -1 Exp: 09/30/24 *4ECTR1�P�ci� Q.ANTUM NEO Technology with optimized module layout boosts module efficiency up to 22.4%. A reliable investment Inclusive 25-year product warranty and 25-year linear performance warranty'. Enduring high performance Long-term yield security with Anti LeTID Technology, Anti PID Technology2, Hot -Spot Protect. Extreme weather rating High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (3600 Pa). Innovative all-weather technology Optimal yields, whatever the weather with excellent low -light and temperature behaviour. The most thorough testing programme in the industry Qcells is the first solar module manufacturer to pass the most comprehensive quality programme in the industry: The new "Quality Controlled PV" of the independent certification institute TUV Rheinland. See data sheet on rear for further information. APT test conditions according to IEC/TS 62804-1:2015, method A (-1500V, 96 h) cem�pnm w (67111,7, r N BLK M-G2+ SERIES ■ Mechanical Specification Format 67.8 in x 44.6 in x 1.18 in (including frame) (1722 mm x 1134 mm x 30 mm) Weight 47.2 Ibs (21.4 kg) Front Cover 0.13 in (3.2 mm) thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Cell Black anodised aluminium 6 .18 monocrystalline Q.ANTUM NEO solar half cells Junction box 2.09-3.98in x 1.26-2.36inx 0.59-0.71in (53-101 mm x 32-60 mm x 15-18 mm), Protection class IP67, with bypass diodes Cable 4mm2 Solar cable; (+)>59.4 in (1510 mm), (-)>_ 59.4 in (1510mm) Connector Staubli MC4; IP68 ■ Electrical Characteristics 36.6 1960m161 ,a.6.071mon 4. a,«,wreP ae016 145mm1 Label a . Mounting slots ▪ IDaTAaa =ssa•(worn.) 6 Es.8,8,81umM rpo mml POWER CLASS 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W /-0 W) E E Power at MPP' Short Circuit Current' Open Circuit Voltage' Current at MPP Voltage at MPP Efficiency' PMPP [W] [A] Isc Von [V] MPP [A] VMPP M n [%] MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 E E 3 Power at MPP Short Circuit Current Open Circuit Voltage Current at MPP Voltage at MPP PMPP [W] Isc [A] Voc M ImPP [A] VMPP [V] 410 13.39 38.58 12.68 32.32 >_ 21.4 310.0 10.79 36.61 9.97 31.09 415 415 13.42 38.61 12.75 32.55 >_ 21.6 313.8 10.82 36.63 10.03 31.29 DETAIL oAaI n6�1 o5r2455onn I-OI0ar a 5 mml 420 420 13.46 38.64 12.82 32.77 >_ 21.9 317.6 10.84 36.66 10.09 31.48 425 425 13.49 38.67 12.88 32.98 a 22.2 321.4 10.87 36.69 10.15 31.66 'Measurement tolerances PMPP±396; Isc: Voc±5% at STC: 1000 W/m2, 25±2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m2. NMOT, spectrum AM 1.5 °cells PERFORMANCE WARRANTY 05 10 15 At least 98.5% of nominal power during first year. Thereafter max. 0.33%degradation per year. At least 95.53 % of nominal power up to 10 years. At least 90.58% of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the °cells sales 20 25 organisation of your respective YEARS country. 'Standard terms of guarantee for the 5 PV companies highest production capacity in 2021(February 2021) TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc Temperature Coefficient of PMPP th the ■ Properties for System Design Maximum System Voltage Maximum Series Fuse Rating Max. Design Load, Push/Pull' Max. Test Load, Push/Pull' ' See Installation Manual vsos [V] [A DC] [Ibs/ft2] [Ibs/ft2] ■ Qualifications and Certificates Quality Controlled PV - TUV Rheinland; IEC 61215,2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. QsNA°SIA .730 C E a [%/K] y [%/K] PERFORMANCE AT LOW IRRADIANCE 110 ± 100 o w 80 200 900 800 800 1000 IRRADIANCE [W/m') Typical module performance under low irradiance conditions in comparison to STC conditions (25°C,1000 W/m). +0.04 Temperature Coefficient of Voc -0.30 Nominal Module Operating Temperature 1000 (IEC)/1000 (UL) PV module classification 20 Fire Rating based on ANSI/UL 61730 75 (3600 Pa)/50 (2400 Pa) 113 (5400 Pa)/75 (3600 Pa) Permitted Module Temperature on Continuous Duty 430 430 13.53 38.70 12.95 33.20 >-22.4 325.2 10.90 36.71 10.21 31.85 [3 [%/K] -0.24 NMOT [°Fl 109±5.4 (43+-3°C) Class II C / TYPE 2 -40°F up to +185°F (-40 °C up to +85 °C) Qcells pursues minimizing paper output in consideration of the global environment. Note: Installation instructions must be followed. Contact our technical service for further information on approved installation of this product. Hanwha 0 CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA 1 TEL +1 949 748 59 961 EMAIL hqc-inquiry@gcells.com 1 WEB www.gcells.com ()cells ® Ocelle O.TRON_BLK M-G2 ubject to technic MODULE DATA SHEET PLANET SOLAR I 73820 DINAH SHORE DRIVE PALM DESERT, CA, 92211 LIC# 938313, CLASS B, C10 760.341.1413 ZEKE©PLANETSOLAR.COM SIGNED: DATE: 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: SQ.FT D-1 5 Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US O 0 O E) O solar;;,, IL • r Q O O - BolarZa HD 0 0 O SJ3flJ3AN Optimized installation with HD -Wave technology ► Specifically designed to work with power optimizers ■ Record -breaking 99%weighted efficiency ► Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 solaredge.com INVERTER DATA SHEET SCALE: N.T.S. 1 UL1741 SA certified, for CPUC Rule 21 grid compliance ► Small, lightweight, and easy to install both outdoors or indoors / Buift-in module -level monitoring ► Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solar-••= / Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER APPLICABLE TO INVERTERS WITH PART NUMBER OUTPUT SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US SEXXXXH-XXXXXBXX4 Rated AC Power Output 3000 3800 @ 240V 3300 @.208V- 5000 6000 @ 240V 5000 @ 208V 7600 10100 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @.208V. 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min —Nor —Max_ (211 -.240 - 264) V V V V .i sI i Vac AC Output Voltage Min. -Nam. -Max (183 - 208 - 229) - ✓ - ✓ - - ✓ Vac AC Frequency (Nominal) 59.3 - 50 - 505i0 Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V _ 16 - 24 - - 48.5 A Power Factor 1, Adjustable-0,85.to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection. Country Conk urable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 I 17550 W Maximum DC Power @208V - 5100 - 7750 - - 1 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vtfc Maximum Input Current @240Vu 8.5 10.5 135 I 165 20 27 I 30.5 Ade Maximum Input Current @208Va - 9 - 13.5 - - I 27 Adc Max. Input Short CircuitCurrent 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ku Sensitivity Maximum Inverter Eltdency 99 I 99.2 %s CEC Weighted Efficiency 99 99 @ 244V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1).For other regional settings please contact So a rEdge support (33 A higher current source may be used; the Inverter Vol II Iimlt its Input airrent to the values stated E 21635 —I CD Exp: 09/30/24 F\CTRI����Q e-0 CA`�Fo Signed. 12/23 INVERTER DATA SHEET w U z w V) o Lr) N Q N < Z Q Q J Q Lin I— Z_ Wp 0-) Z LC) > Q w PLANET SOLAR 73820 DINAH SHORE DRIVE PALM DESERT, CA, 92211 LIC# 938313, CLASS B, C10 760.341.1413 ZEKE©PLANETSOLAR.COM SIGNED: DATE: 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: ---- SQ.FT D-2 6 Power Optimizer For Residential Installations S440, S500 -0 Q m 70 O -0 N rn Enabling PV power optimization at the module level ► Specifically designed to work with SolarEdge residential inverters ► Detects abnormal PV connector behavior, preventing potential safety issues* ► Module -level voltage shutdown for installer and firefighter safety ► Superior efficiency (99.5%) > Function itysubject to Inverter model and firmware sersdn solaredgo.com OPTIMIZER DATA SHEET SCALE: N.T.S. / Mitigates all types of module mismatch foss, from manufacturing tolerance to partial shading / Faster installations with simplified cable management and easy assembly using a single bolt ► Flexible system design for maximum space utilization ► Compatible with bifacial PV modules solar-•. / Power Optimizer For Residential Installations S440, S500 S440 ssoo UNIT Rated Input DC PoWert' 440 500 W Absolute Maximum I nput Voltage (Vol 60 Vdc MP PT Operating Range 9 - 60. Vdc Maximum Short Circuit Current (rsc) of Connected PV Module 14.5 1 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current Maximum Output Voltage 15 60 Adc Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer STANDARD COMPLIANCE Vdc EMC FCC Part 15 Class 3., IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011. Safety IEC62109-1 (das-II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-7122013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 mm Weight (including cables) 655 / 1.5 gr (Ib Input Connector MC4. Input Wire Length 0.1 m Output Connectdr MC4 Dutput Wire Length (t-) 2.3. (-) 010 m Operating Temperature Range," -40 to+85 `C Protection Rating IP68./ NEMA6P Relative Humidity 0- 100 (n RalEd power of the module at STC will noteaneed the Power optimizer Rated Input DC Power, Modules with u p to +5% power tolerance are allowed (2) For other connector types please conta7Solaredge (3) For ambient temperature abose+79°C/ +158"F power de -rating is a pplied Refer to Power Caim ¢ers Temperature De-Ratlno Technical Note for more details PV system Design Using a SoiarEdge Inverter Single Phase HD -Wave Three Phase Minimum String Length 5440, 5500 (Power Optimizers) Maximum Strng Length (Power Optimizers) 8 25 Maximum Nominal Power per Sitingl"e 5700 16 112501" Three Phase for 277/48DV Grid 50 IS 12730 w Parallel Sfringsof Different Lengths or Orientations Yes (4) If the Inverters rated AC powers maximum nominal power pef string, then the m avlmum power per stri hq will be able tv reach up.to the Inverters Irlaximum input DC power Rerertn: https//wwwsal aredpe conysites/default/Ales/se-power-optimizer-single-strirg-design-appikation-note,pdf (5) For the 239/490V gr id: it Is allowed to install up to 13,500W per string when the maximum pourer differerre between each string is 2,909 W (6) For the 277/4836 grid: R is allowed to Install up to 15;996W per string when the maximum power difference between each string is 2p50W (7) It Is not allowed to mix S-series and P-series Poker 13 ptlmiaers In new installations sr I lA SolarEdge Ter h. logic; Inc All rig h. ren.mod SOLI, REDGE. Om SO larEdge Iced OPTINI I=ED 9Y SOLAR EDGE are trademarks or regctered trademarks of Snlartdge Tech no log ic; Inc All of her trademarks mentioned herein are trade mans of then respects a ow nerx Date 12/2021 DS.000091-12-ENG S wizen to change without nod et. c€ RoHS OPTIMIZER DATA SHEET PLANET SOLAR 73820 DINAH SHORE DRIVE PALM DESERT, CA, 92211 LIC# 938313, CLASS B, C10 760.341.1413 ZEKE©PLANETSOLAR.COM SIGNED: DATE: 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: SQ.FT D-3 7 'AL IRON RIDGE Roof Protection without Compromise The L-Mount attachment, featuring an open -slotted L-Foot, is designed for cost-effective, single -bolt installation onto existing composition (asphalt) shingle roofs. The patented Elevated Water Seal Technologye has been integrated into the open -slotted L-Foot and flashing for fast installation, to provide maximum waterproofing. To maximize versatility, the mount is available with a lag bolt or structural screw option for the strength you depend on. Both hardware options come with an installed EPDM bonded washer to seal and prevent water entry. L-Mount features a 9x12" aluminum flashing with alignment guides and rounded corners, to easily slide under shingles and speed up installation on the roof. The kit is available in both mill and black finishes. Qs., This component is part of the QuickMount" product line_ Pre -Installed Sealing Washer Harware options include a lag bolt or structural screw. The EPDM washer arrives already attached. us Intertek 25-Year Warranty Product guaranteed free of impairing defects. Tech Brief QuickMount_" L-Mount® Elevated Water Seal Technology® This proprietary flashing design cleverly places the roof penetration seal onto an aluminum flute fused into the flashing, above the bolt hole. The secondary EPDM rubber seal keeps water out —raised above the path of rain water and out of harm's way. Open -Slotted L-Foot The redesigned L-Foot can rotate 360 degrees for optimal adjustability and positioning of the rail, while the open slot allows the rail hardware to quickly drop -in and be compatible with any side - mounted racking on the market. Tech Brief L-Mounf Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" or 1/8" bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be mounted. Select the courses of shingles where mounts will be placed. If attaching with lag bolt use a'h2" bit (Lag).. Use a Vs" bit (ST) for attaching with the structural screw. Drill pilot hole into roof and rafter, taking care to drill squaretothe roof. Do not use mount asa drill guide. Drills 2" deep hole into rafter. Prepare lag bolt or structural screw With sealing washer. Using a'h-inch socket on an impact gun, drive prepared lag bolt through L-foot until L-foot can no longer easily rotate. DO NOT over -torque. NOTE: Structural screw can be driver with T-30 hex head bit. Carefully lift composition roof shingle with roofing Insert flashing between 1st and end course. Slide bar, just above placement of mount. Remove up so top edge of flashing is at least 3/4" higher nails as required and backlit' holes with aproved than the butt -edge of the 3rd course and lower sealant. See "Proper Flashing Placement" on next flashing edge is above the butt -edge of let course. page. Mark center for drillmg Clean off any sawdust, and fill hole with sealant compatible with roofing materials. You are now ready for the rack of your choice. Follow all the directions of the rack manufacturer as well as the module manufacturer. NOTE: Make sure top of L-Foot makes solid contact with racking. 6 Place L-foot onto elevated flute and rotate L-foot to desired orientation. All roofing manufacturers' written instructions must also be followed by anyone modifying a roof system. Consult the roof manufacturer's specs and instructions prior to working on the roof. +s� 2921 IronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information. Version 1.21 ATTACHMENT DATA SHEET w 0 Z w r') o rr) W Q Z 0 aQ J Q Ln Wp 0-) Z rr) O > Q w w 1- 0 W z 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: SQ.FT D-4 ATTACHMENT DATA SHEET SCALE: N.T.S. 8 fi IRON RIDGE Datasheet Roof Mount System Built for cngar'S tofuQhest rnnfs . Iron Ridge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Integrated Grounding UL 2703 system eliminates separate module grounding components. PE Certified Pre -stamped engineering letters available in most states. Design Software Online tool generates a complete bill of materials in minutes. 20 Year Warranty Twice the protection offered by competitors. - XR Rails XR10 Rail A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate Toad capability • Clear & black anod. finish Attachments FlashFoot Anchor, flash, and mount with all -in -one attachments. • Ships with all hardware • IBC & IRC compliant • Certified with XR Rails Clamps & Grounding End Clamps anew Slide in clamps and secure modules at ends of rails. • Mill finish & black anod. • Sizes from 1.22" to 2.3" • Optional Under Clamps - Free Resources XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability Heavy load capability • Clear & black anod. finish Slotted L-Feet Drop -in design for rapid rail attachment. • High -friction serrated face • Heavy-duty profile shape • Clear & black anod. finish Grounding Mid Clamps Attach and ground modules in the middle of the rail. Parallel bonding T-bolt Reusable up to 10 times Mill &black stainless 5._.. Design Assistant Go from rough layout to fully engineered system. For free. IronRidge.corni. .. XR1000 Rail A heavyweight mounting rail for commercial projects. • 12' spanning capability • Extreme load capability • Clear anodized finish Standoffs Raise flush or tilted systems to various heights. • Works with vent flashing • Ships pre -assembled • 4" and 7" Lengths T-Bolt Grounding Lugs Ground system using the rail's top slat. • Easy top -slot mounting • Eliminates pre -drilling Swivels in any direction Datasheet Internal Splices ; ] All rails use internal splices for seamless connections. • Self -tapping screws • Varying versions for rails • Grounding Straps offered Tilt Legs Tilt assembly to desired angle, up to 45 degrees. • Attaches directly to rail • Ships with all hardware • Fixed and adjustable Accessories Provide a finished and organized look for rails. • Snap -in Wire Clips • Perfected End Caps • UV -protected polymer y 1 4 NABCEP Certified Training i' W Earn free continuing education credits, 4 x while learning more about our systems. r 4 Go to Ironk. _.)e.com/training 20141 ranridge, Inc. All rights reserved. Volt www.vannelge.com or call 1-000-227.9523 for more information, Version 1.42 RAIL DATA SHEET W 0 N CO W N o<< = 0 J �� 0 < �w JCK OQwM z (zu)rn i< aW00•J H W M Q_ W O CD g Z N W -JN)QO(Oow wNo-_rNI O O J 0 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: SQ.FT D-5 RAIL DATA SHEET SCALE: N.T.S. 9 JUNCTION BOX & CONDUIT RACEWAYS NEC 690.31(E)(3) - CONDUIT / ALL JUNCTION BOXES WARNING: PHOTOVOLTAIC POWER SOURCE NEC 690.35(F) - UNDERGROUND SYSTEM JUNCTION BOXES WARNING: ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE ENERGIZED. DC DISCONNECTS NEC 690.14(4) GROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.35(F) UNGROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE ENERGIZED. NEC 690.14(C)(2) PHOTOVOLTAIC DC DISCONNECT NEC 690.53 "GRID -TIED PHOTOVOLTAIC POWER SOURCE" OPERATING CURRENT: 47.5A OPERATING VOLTAGE: 400V MAXIMUM SYSTEM VOLTAGE: 480V MAXIMUM SYSTEM CURRENT: 59.375A MAXIMUM INVERTER OUTPUT:11,400W, 59.375A, 240VAC INVERTER/PV LOAD CENTER NEC 690.5(C) - GROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNDERGROUND AND ENERGIZED (CEC 705.12(B)(2)(3) WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. NEC 690.35(F) - UNGROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE ENERGIZED PRODUCTION METER ONLY AT METER LOCATION PHOTOVOLTAIC SYSTEM METER AC DISCONNECTS NEC 690.14(C)(2) PHOTOVOLTAIC AC DISCONNECT NEC 690.54 NOMINAL AC VOLTAGE RATED AC OUTPUT CURRENT 240V 47.5A NEC 705.12(D)(4) - ON A LINE SIDE TAP WARNING: DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM WARNING PLACARDS SCALE: N.T.S. MAIN SERVICE PANEL NEC NEAR PV BREAKER WARNING: POWER SOURCE OUTPUT CONNECTION- DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(4), 690.56(B) - ON PANEL COVER WARNING: DUAL POWER SOURCE POWER IS BEING SUPPLIED TO THIS PANEL FROM THE UTILITY AND A SOLAR PV SYSTEM. THE SOLAR PV DISCONNECT IS LOCATED: NEC 690.14(C)(2) - NEAR PV BREAKER PHOTOVOLTAIC AC DISCONNECT NEC 690.54 - ON PANEL COVER NOMINAL AC VOLTAGE RATED AC OUTPUT CURRENT 240V 47.5A RED SIGNAGE W/WHITE 1/4" FONT CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 12/27/2023 BY F RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC 690.56(C)(3) - WHITIN 3' OF RAPID SHUTDOWN SWITCH 690.56(C) Buildings with Rapid Shutdown. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. IGURE 690.56(C)(1)(a) label for PV Systems that Shut Down the Array and the Conductors leaving the Array A PLOT MAP LOCATING THE POWER SOUCRES WITH DISCONNECTS SHALL BE FURNISHED BY THE SOLAR INSTALLER NEAR THE MAIN SERVICE PANEL IN A VISIBLE LOCATION RED SIGNAGE CAUTION W/WHITE 3/8" FONT POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: ADDRESS: 59315 ALMERIA, LA QUINTA, CA 92253 (N)SOLAR PHOTOVOLTAIC ARRAY ON ROOF EQUIPPED WITH RAPID SHUTDOWN II Lell II E..' II kill \\\\\• MMI mreAi (N)PV SYSTEM DISCONNECT FOR UTILITY OPERATION (E)UTILITY METER AND MAIN SERVICE DISCONNECT RED SIGNAGE W/WHITE 1/8" FONT TYP. WARNING PLACARDS W U z w V) 0 Lf) N W Q �wQ z Q J Q z zLr)0 > < J w PLANET SOLAR I 73820 DINAH SHORE DRIVE PALM DESERT, CA, 92211 LIC# 938313, CLASS B, C10 760.341.1413 ZEKE©PLANETSOLAR.COM SIGNED: DATE: 12.13.2023 DRAWN BY: BPM APN: 764691082 LOT:0.28 ACRES DWELLING: SQ.FT L-1 10