FA2018-0007ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Jeff Rodgers 4585 Murphy Canyon Road SAN DIEGO CA 92123 (858)560-7000 jrodgers@hcisystems.n et OWNER REDEVELOPMENT AGENCY CITY OF P O BOX 1504 LA QUINTA CA 92253 (858)560-7000 CONDITIONS Description: WASHINGTON ST APTS PHASE 2 BUILDINGS K,L,M,N,O,P,Q,R,S,T&COM Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - SPRINKLER MONITORING Status: APPROVED Applied: 8/13/2018 EPRS Parcel No: 609040028 Site Address: WASHINGTON STREET APARTMENTS PHASE 2 LA QUINTA,CA 92253 Approved: 8/28/2018 EGO Subdivision: Block: Lot: Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $28,320,239.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY Credit Card Fee 101-0000-43505 0 $7.29 $7.29 8/13/18 WEB2814 CREDIT Jeff Rodgers EPRS Total Paid for Credit Card Fee: $7.29 $7.29 Printed: Tuesday, March 12, 2024 2:49:23 PM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2018-0007 INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 8/13/2018 8/14/2018 8/14/2018 COMPLETE 8/28/2018 Jeff Rogers HCI Systems 4585 Murphy Canyon Rd. San Diego CA, 92123 Re: Fire Alarm System Plan Review – Washington PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS 101-0000-42421 0 $156.00 $156.00 8/13/18 WEB2814 CREDIT Jeff Rodgers EPRS FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS PC 101-0000-42420 0 $234.00 $234.00 8/13/18 WEB2814 CREDIT Jeff Rodgers EPRS Total Paid for FIRE FEES: $390.00 $390.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 8/13/18 WEB2814 CREDIT Jeff Rodgers EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 8/13/18 WEB2814 CREDIT Jeff Rodgers EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$412.29 $412.29 Printed: Tuesday, March 12, 2024 2:49:23 PM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2018-0007 Street Apartments FA2018-0007 42-800 Washington St. La Quinta CA The alarm plans you submitted for the above referenced project have been reviewed by the Riverside County Fire Department and are approved with the following conditions: 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. All fire alarm notification and initiating appliances shall be tested in accordance with NFPA 72. c) 5-Minute Ring-out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site- specific software and equipment specifications shall be provided in a documentation cabinet in Printed: Tuesday, March 12, 2024 2:49:23 PM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2018-0007 1ST FIRE (2 WK)EDGAR GONZALEZ 8/13/2018 8/27/2018 8/28/2018 APPROVED- CONDITIONS compliance with NFPA 72 Section 7.7.2 5. A zone map indicating location of all initiating devices shall be installed at an approved location. 6. All equipment keys shall be provided for placement in building’s KNOX box systems for Fire Department access. 7. All j-boxes and electric boxes serving fire alarm system shall be red in color or labeled. 8. Compartment/room containing fire alarm equipment that is capable of system operation shall be labeled "FACP" on exterior side. 9. All electrical breaker circuit switches controlling fire alarm power source shall be locked in the ON position for the life of the system by an approved lock-out assembly. 10. All signals witnesses at function testing shall be verified before final approval is granted. The Fire Department approved plans, job card and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)863-8886. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is Printed: Tuesday, March 12, 2024 2:49:23 PM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2018-0007 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/28/2018 EDGAR GONZALEZ FAS2018-0007 - WASHINGTON STREET APARTMENTS - FIRE ALARM PHASE 2 - (COA).docx FAS2018-0007 - WASHINGTON STREET APARTMENTS - FIRE ALARM PHASE 2 - (COA).docx 1 DOC 8/28/2018 EDGAR GONZALEZ 2018-08-13_Washington St Apts_FA Phase 2 - APPROVED DRAWINGS.pdf 2018-08-13_Washington St Apts_FA Phase 2 - APPROVED DRAWINGS.pdf 1 DOC 8/13/2018 EtrakitPublicReg FIRE ALARM PLANS 2018-08-13_Washington St Apts_FA Phase 2.pdf 1 DOC 8/13/2018 EtrakitPublicReg PRODUCT SUBMITTAL 2018-07-24_Washington St Apts_Product Submittal.pdf 1 BOND INFORMATION subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez Fire Safety Specialist Printed: Tuesday, March 12, 2024 2:49:23 PM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2018-0007 BUILDING INFORMATIONSCOPE OF WORKVICINITY MAPGENERAL NOTESWIRE LEGENDBPBACKFLOW PREVENTERCSFDCOMBINATION SMOKE / FIRE DAMPEREOLEND-OF-LINE RESISTOREREXISTING DEVICE TO BE REMOVEDERREXISTING DEVICE TO BE REMOVEDAND REPLACED WITH NEWEXEXISTING DEVICE TO REMAINFACPFIRE ALARM CONTROL PANELFATCFIRE ALARM TERMINAL CABINETLRMLOCAL RAIL MODULENNEW DEVICEPIVPOST INDICATOR VALVERREXISTING DEVICE TO BE REMOVEDAND RELOCATEDAPPLICABLE CODES & REGULATIONSSEQUENCE OF OPERATIONFPLFIRE-POWER LIMITEDFPLPFIRE-POWER LIMITED PLENUMFPLRFIRE-POWER LIMITED RISERTPTWISTED PAIRTSPTWISTED SHIELDED PAIRTHHN"T" THERMOPLASTIC INSULATED CABLE"HH" MEANS THAT THE WIRE IS HEAT RESISTANT AND CAN WITHSTAND A HIGHER TEMPERATURE (UP TO 194° F)"N" NYLON COATING THAT COVERS WIRE INSULATIONTHWN"T" THERMOPLASTIC INSULATED CABLE"H" MEANS WIRE IS HEAT RESISTANT"W" MEANS WIRE IS APPROVED FOR DAMP/WET LOCATIONS"N" NYLON COATING THAT COVERS WIRE INSULATIONWPWEATHERPROOF DEVICEABBREVIATIONSSYMBOL LEGENDDRAWINGS NOT PLOTTED 30" X 42" ARE NOT TO SCALEDEVICE LEGENDV1-22DENOTES NOTIFICATIONDEVICE NUMBERDENOTES NOTIFICATIONCIRCUIT NUMBERDENOTES DEVICE TYPEDENOTES AUDIO/VISUAL(WALL-MOUNTED) DEVICE SYMBOL15CDDENOTES CANDELA RATINGV1EOLEND-OF-LINE RESISTORDENOTES END-OF-LINE FORCIRCUIT #V1V1-22DENOTES NOTIFICATIONDEVICE NUMBERDENOTES NOTIFICATIONCIRCUIT NUMBERDENOTES DEVICE TYPEDENOTES VISUAL (WALL-MOUNTED)DEVICE SYMBOL15CDDENOTES CANDELA RATINGV1EOLEND-OF-LINE RESISTORDENOTES END-OF-LINE FORCIRCUIT #V1NOTIFICATION DEVICES:1.) ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH N.E.C. ARTICLE 760, POWER LIMITED FIRE PROTECTIVE SIGNALING CIRCUITS.2.) UPON COMPLETION OF THE INSTALLATION OF THE FIRE ALARM SYSTEM, A SATISFACTORY TEST OF THE ENTIRE SYSTEM SHALL BE MADE IN THEPRESENCE OF THE FIRE MARSHAL.3.) A STAMPED SET OF APPROVED FIRE ALARM PLANS SHALL BE ON THE JOB SITE AND USED FOR INSTALLATION. ANY DEVIATION FROM APPROVEDPLANS, INCLUDING THE SUBSTITUTION OF DEVICES, SHALL BE APPROVED BY THE FIRE MARSHAL.4.) ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE CODE OR RECOGNIZED STANDARDS SHALL BE BROUGHT TO THE ATTENTION OF THEINSPECTOR OF RECORD. 5.) ALL DEVICES OF THE FIRE ALARM SYSTEM SHALL BE APPROVED AND LISTED BY THE CALIFORNIA STATE FIRE MARSHAL.6.) FIRE ALARM DEVICES SHALL BE INSTALLED PER N.F.P.A. 72.7.) ALL WIRING, ANNUNCIATING DEVICES AND ANNUNCIATOR SHALL BE SUPERVISED AT THE PRINCIPAL POINT OF ANNUNCIATION.8.) WIRING SHALL NOT BE LOOPED THROUGH DEVICES; WIRE MUST BE CUT AT EACH DEVICE.9.) ALL WIRING SHALL BE INSTALLED FREE-AIR UNLESS NOTED IN CONDUIT. CONDUIT SIZE SHALL BE 3/4" MINIMUM UNLESS OTHERWISE NOTED.10.) ALL CONDUCTORS ARE COPPER.11.) SYSTEM IS POWER LIMITED.12.) POINT AND COMMON ANNUNCIATION AND T-TAPPING PROHIBITED.13.) ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED TO MANUFACTURERS SPECIFICATIONS.14.) AUDIBILITY OF ALARM AND VOICE COMMUNICATION SHALL BE NOT LESS THAN 15 db ABOVE AMBIENT SOUND THROUGHOUT AREA OF ALARM.15.) AREAS HAVING MORE THAN 2 STROBES IN THE FIELD OF VIEW SHALL BE SYNCHRONIZED.16.) SMOKE DETECTORS AND HEAT DETECTOR LOCATION ARE BASED ON SMOOTH CEILING WITH MAXIMUM HEIGHT OF 10 FEET UNLESS OTHERWISENOTED.17.) STROBE LOCATION IS BASED ON 10 FOOT CEILING HEIGHT AND ARE INSTALLED ACCORDING TO NFPA 72 REQUIREMENTS UNLESS OTHERWISENOTED.18.) WALL-MOUNTED STROBES SHALL HAVE THEIR BOTTOMS NOT LESS THAN 80 INCHES ABOVE FINISHED FLOOR AND NO GREATER THAN 96 INCHESABOVE FINISHED FLOOR.19.) CENTER OF PULL STATIONS SHALL BE MOUNTED AT 48" ABOVE FLOOR LEVEL.20.) ALL CONDUIT AND J-BOXES SERVING FIRE ALARM CIRCUITS SHALL BE PAINTED RED AND LABELED FA.21.) POWER FOR THE FIRE ALARM CONTROL PANEL IS TO BE PROVIDED BY A DEDICATED CIRCUIT BREAKER, AHEAD OF THE MAIN CIRCUIT BREAKER.INDICATE LOCATION OF THIS BREAKER AT THE FACP. BREAKER TO BE RED AND LABELED "FIRE ALARM CONTROL DISCONNECT".22.) ELECTRICAL POWER SERVICE SHALL BE ON A DEDICATED CIRCUIT(S). THE CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLYPROTECTED (CIRCUIT BREAKERS SHALL BE LOCKED IN THE ON POSITION WITH AN APPROVED MECHANICAL CLIP.) CIRCUIT DISCONNECTING MEANSSHALL HAVE A RED MARKING, SHALL BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT". THELOCATION OF THE CIRCUIT DISCONNECTING MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 2016 NFPA 72 10.5.5.1AND 10.5.5.3.23.) ALL OUTSIDE CONTROL VALVES, FLOW SWITCHES AND ELECTRICAL JUNCTION BOXES SHALL HAVE ELECTRICALLY SUPERVISED COVERS.ELECTRICAL JUNCTION BOXES MAY HAVE TAMPER PROOF SCREWS IN PLACE OF ELECTRICAL SUPERVISION. THIS PROVISION IS SPECIFICALLYDIRECTED TO EQUIPMENT USED OUTSIDE A BUILDING WHERE TAMPERING WITH THE FIRE ALARM SYSTEMS IS POSSIBLE. 2016 NFPA 72 23.8.5.11.2.24.) PROVIDE ELECTRICAL MONITORING FOR ALL EXTERIOR CONTROL VALVES CONTROLLING THE WATER SUPPLY FOR THE SPRINKLER SYSTEMS. THISINCLUDES, PIV'S, DOUBLE CHECK DETECTOR ASSEMBLY, ETC. ALL SECTIONAL CONTROL VALVES FEEDING THE ON-SITE WATER SUPPLIES AREELECTRONICALLY MONITORED. ALL CONTROL VALVES SHALL BE LOCKED IN THE POSITION WITH A NON-CASE-HARDENED LOCK. THE EXISTINGBELOW GRADE SECTIONAL VALVES SHALL BE ELECTRONICALLY MONITORED. THE SECTIONAL VALVES SHALL BE WIRED TO THE CLOSEST RESPECTIVEBUILDING PER EXISTING CONDITIONS. WHERE A SECTIONAL AFFECTS THE WATER DISTRIBUTION TO MULTIPLE BUILDINGS, EACH BUILDING AFFECTEDSHALL INDICATE A SUPERVISORY CONDITION WHEN A VALVE IS IN THE OFF-NORMAL POSITION.25.) FIRE ALARM CONDUCTORS USED IN WET OR UNDERGROUND LOCATIONS SHALL BE OF TYPE THWN.26.) FIRE ALARM SYSTEM "RECORD OF COMPLETION" DOCUMENT SHALL BE PROVIDED TO THE CLIENT ALONG WITH THE OTHER REQUIREDCLOSE-OUT DOCUMENTATION AT THE TIME OF SYSTEM ACCEPTANCE AND APPROVAL PER NFPA 72 10.18.2.27.) WHERE A SMOKE DAMPER IS INSTALLED WITHIN A DUCT, A SMOKE DETECTOR SHALL BE INSTALLED IN THE DUCT WITHIN 5 FEET (1524 mm) OF THEDAMPER WITH NO AIR OUTLETS OR INLETS BETWEEN THE DETECTOR AND THE DAMPER. THE DETECTOR SHALL BE LISTED FOR THE AIR VELOCITY,TEMPERATURE AND HUMIDITY ANTICIPATED AT THE POINT WHERE IT IS INSTALLED. OTHER THAN IN MECHANICAL SMOKE CONTROL SYSTEMS,DAMPERS SHALL BE CLOSED UPON FAN SHUTDOWN WHERE LOCAL SMOKE DETECTORS REQUIRE A MINIMUM VELOCITY TO OPERATE. (FIRE ANDSMOKE PROTECTION FEATURES 2016 CALIFORNIA BUILDING CODE, 716.3.3.2)28.) WHERE A SMOKE DAMPER IS INSTALLED ABOVE SMOKE BARRIER DOORS IN A SMOKE BARRIER, A SPOT-TYPE DETECTOR LISTED FOR FORRELEASING SERVICE SHALL BE INSTALLED ON EITHER SIDE OF THE SMOKE BARRIER DOOR OPENING. (FIRE AND SMOKE PROTECTION FEATURES 2016CALIFORNIA BUILDING CODE, 716.3.3.2)29.) WHERE A SMOKE DAMPER IS INSTALLED WITHIN AN AIR TRANSFER OPENING IN A WALL, A SPOT-TYPE DETECTOR LISTED FOR RELEASING SERVICESHALL BE INSTALLED WITHIN 5 FEET (1524 mm) HORIZONTALLY OF THE DAMPER. (FIRE AND SMOKE PROTECTION FEATURES 2016 CALIFORNIABUILDING CODE, 716.3.3.2)30) WHERE A SMOKE DAMPER IS INSTALLED IN A CORRIDOR WALL OR CEILING, THE DAMPER SHALL BE PERMITTED TO BE CONTROLLED BY A SMOKEDETECTION SYSTEM INSTALLED IN THE CORRIDOR. (FIRE AND SMOKE PROTECTION FEATURES 2016 CALIFORNIA BUILDING CODE, 716.3.3.2)31.) WHERE A TOTAL-COVERAGE SMOKE DETECTOR SYSTEM IS PROVIDED WITHIN AREAS SERVED BY A HEATING, VENTILATION ANDAIR-CONDITIONING (HVAC) SYSTEM, SMOKE DAMPERS SHALL BE PERMITTED TO BE CONTROLLED BY THE SMOKE DETECTION SYSTEM. (FIRE ANDSMOKE PROTECTION FEATURES 2016 CALIFORNIA BUILDING CODE, 716.3.3.2)32.) DWELLING AND SLEEPING UNIT BATHROOMS SHALL NOT BE REQUIRED TO BE PREWIRED FOR THE CAPABILITY TO SUPPORT VISIBLE ALARMS INGROUP R-2 OCCUPANCIES. THIS IS PER THE CSFM CODE INTERPRETATION 15-001 THAT REFERENCES CODE SECTION 907.5.2.3.4 CBC - 2013 ED.AREA OF WORKNORTHCALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19CCR, TITLE 24, PART 2: 2016 CALIFORNIA BUILDING CODE (CBC)CCR, TITLE 24, PART 3: 2016 CALIFORNIA ELECTRICAL CODE (CEC)CCR, TITLE 24, PART 4: 2016 CALIFORNIA MECHANICAL CODE (CMC)CCR, TITLE 24, PART 9: 2016 CALIFORNIA FIRE CODE (CFC)NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 72, 2016 EDITION,AS AMENDED IN CHAPTER 47 OF THE 2016 CFC.CENTRAL STATIONALARM SERVICE COMPANY: (257057-001)ADVANCED PROTECTION INDUSTRIES, INC.DBA, NATIONAL MONITORING CENTER25341 COMMERECENTRE DR.LAKE FOREST, CA 92630PHONE: (800) 662-1711U.L. NUMBER: #S8126WASHINGTON STREET APARTMENTS - PHASE 242-800 WASHINGTON STREETLA QUINTA, CA 92203SPRINKLER MONITORING SYSTEMPROJECT ADDRESS:42-800 WASHINGTON STREETLA QUINTA, CA 92203LEGAL DESCRIPTION:REFER TO TITLE REPORT FOR FULL LEGAL DESCRIPTION. PARCEL SITUATED IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS:PARCEL 1:BEING A SUBDIVISION OF A PORTION OF THE SOUTHWEST QUARTER OF THE NORTHWEST QUARTER OF SECTION 18, TOWNSHIP 5 SOUTH, RANGE 7 EAST, SAN BERNARDINO MERIDIAN.PARCEL 2:BEING A SUBDIVISION OF A PORTION OF THE SOUTHWEST QUARTER OF THE NORTHWEST QUARTER OF SECTION 18, TOWNSHIP 5 SOUTH, RANGE 7 EAST, SAN BERNARDINO MERIDIAN.APN:609-040-007, 609-040-023, 609-040-028CONSTRUCTION TYPE:V-A; FULLY FIRE SPRINKLEREDOCCUPANCY CLASS:R-2 (APARTMENTS)B (OFFICE)A-3 (COMMON BUILDINGS)BUILDING AREA:4,119 S.F. TOTAL (BUILDING K)5,595 S.F. TOTAL (BUILDING L)5,363 S.F. TOTAL (BUILDING M)4,223 S.F. TOTAL (BUILDING N)4,932 S.F. TOTAL (BUILDINGS O,T)5,595 S.F. TOTAL (BUILDINGS P,R)4,223 S.F. TOTAL (BUILDINGS Q,S)2,567 S.F. TOTAL (BUILDING COMMONS 1)2,484 S.F. TOTAL (BUILDING COMMONS 2)BUILDING HEIGHT:1 STORY - 26'-0" GREATEST BUILDING HEIGHTBUILDING PERMITS:BUILDING “K”        BRES2018-0041BUILDING “L”         BRES2018-0042BUILDING “M”       BRES2018-0043BUILDING “N”        BRES2018-0044BUILDING “O”       BRES2018-0035BUILDING “P”        BRES2018-0036BUILDING “Q”       BRES2018-0037BUILDING “R”        BRES2018-0038BUILDING “S”         BRES2018-0039BUILDING “T”         BRES2018-0040COMMONS 1        BCOM2018-0008COMMONS 2 BCOM2018-0006SHEET INDEXSHEET#SHEET TITLE1DRAWING#FA-00123FA-101FA-102SPRINKLER MONITORING SYSTEMCOVER SHEETSPRINKLER MONITORING SYSTEMBUILDINGS A,B,C,D,E,F,G,H,J,K,L,M,P,R - FLOOR PLANS45FA-701SPRINKLER MONITORING SYSTEMPANEL DETAILS AND CALCULATIONSFA-100SPRINKLER MONITORING SYSTEMOVERALL SITE PLANACTUATECOMMONALARMSIGNALINDICATORSLC LOOP - OPENSMOKE DETECTOR AT PANELWATERFLOW SWITCH ACTIVATEDSPRINKLER VALVE CLOSEDMANUAL PULL STATIONACTIVATEAUDIBLEALARMSIGNALACTUATECOMMONSUPERVISORYSIGNALINDICATORACTUATEAUDIBLESUPERVISORYSIGNALACTUATECOMMONTROUBLESIGNALINDICATORACTUATECOMMONTROUBLESIGNALNOTIFICATIONAPPLIANCECIRCUITSACTIVATEDTRANSMIT FIREALARM SIGNALTO CENTRALSTATIONTRANSMITSUPERVISORYSIGNAL TOCENTRALSTATIONTRANSMITTROUBLESIGNAL TOCENTRALSTATIONSPRINKLERBELL(BY OTHERS)SLC LOOP - SHORTSLC LOOP - EARTH GROUNDINITIATING DEVICE CIRCUIT - OPENINITIATING DEVICE CIRCUIT - SHORTINITIATING DEVICE CIRCUIT - EARTH GROUNDNOTIFICATION CIRCUIT - OPENNOTIFICATION CIRCUIT - SHORTNOTIFICATION CIRCUIT - EARTH GROUNDAC FAILLOW BATTERYYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESRESPONSEACTIONYESYESYESYESYESVANOTIFICATIONADDRESSABLE CIRCUITCALLOUTUSAGETYPE14-2 FPLRUNDERGROUND CIRCUITU14-2 FPLR---COLOR------SOLIDSOLIDMANUFACTURERCATALOG #DESCRIPTIONMOUNTING INFORMATIONCSFMQTYSYMBOLFIRE ALARM DEVICE LEGENDBOSCHFPD 7024FIRE ALARM CONTROL PANELENCLOSURE TO BE FURNISHED BY HCI;INSTALLED BY E.C.7165-1615:0227FACP12BOSCHD7052DUAL INPUT MODULE4" SQ DEEP ELEC BOX7165-1615:0227AIMD27BOSCHB450PLUG-IN COMMUNICATOR INTERFACEMOUNTS INSIDE FACP7165-1615:022712xxCD = CANDELA RATINGxW = SPEAKER TAP WATTAGEEOL = END OF LINEFBO = FURNISHED BY OTHERSWP = WEATHER PROOF DEVICEBOSCH D263INTELLIGENT PHOTOELECTRIC SMOKE DETECTOR4" SQ DEEP ELEC BOX7272-1615:0134SP12BOSCHFMM-7045MANUAL PULL STATION4" SQ DEEP ELEC BOX - SINGLE GANG RING7150-1615:0122F12BY OTHERSFIRE ALARM TERMINAL CABINETN/AN/AFATC-N/AWATER FLOW SWITCH/TAMPER SWITCHN/AN/AWFTS-N/ABACKFLOW PREVENTORN/AN/ABFP-N/APOST INDICATING VALVEN/AN/APIV-SPACE AGEELECTRONICSFIRE ALARM DOCUMENT CABINETINCLUDED7300-0553:0110FAD12DSCLE4010CF-ATFIRE ALARM CELLULAR ALARM COMMUNICATORINCLUDED7300-1273:0505CELL12APPLIANCE CIRCUIT18-2 FPLRSOLIDINTENT:INSTALLATION OF A NEW SPRINKLER MONITORING SYSTEM, IN BOTH RENOVATED EXISTING BUILDINGS AND NEWLY CONSTRUCTED BUILDINGS.SCOPE OF WORK:THE SPRINKLER MONITORING SYSTEM INSTALLATION WITHIN THE APARTMENTS SHALL MEET NFPA 72 STANDARDS. THIS INCLUDES DETECTION DEVICES,MONITOR MODULES, AND A PULL STATION. NO HVAC UNITS ARE OVER 2,000 CFM, SO NO SHUTDOWN IS REQUIRED. EXISTING BUILDINGS SHALLHAVE NEMA 3R ENCLOSURES TO HOUSE THE FACP AND EQUIPMENT SINCE NO ROOM IN THE EXISTING BUILDINGS ARE PROVIDED.TYPE OF SPRINKLER MONITORING SYSTEM:THIS SPRINKLER MONITORING SYSTEM IS A MANUAL AND AUTOMATIC SYSTEM.SPRINKLER MONITORING SYSTEMBUILDINGS N,O,Q,R,T, & COMMONS - FLOOR PLANSPROJECT TEAMOWNER:CITY OF LA QUINTA78-495 CALLE TAMPICOLA QUINTA, CA 92253ARCHITECT:STUDIO E ARCHITECTS2258 1ST AVENUESAN DIEGO, CA 92101TEL: (619) 235-9262CONTACT: ERIC NASLUNDSTRUCTURAL:TKJ STRUCTURAL ENGINEERING9820 WILLOW CREEK ROAD, SUITE 455SAN DIEGO, CA 92131TEL: (858) 649-1700CONTACT: BO JAQUESSMECHANICAL / PLUMBING:BTA ENGINEERS, INC.9845 ERMA RD, SUITE 204SAN DIEGO, CA 92131TEL: (858) 715-6601MECHANICAL CONTACT: BONG MANLULUPLUMBING CONTACT: ALLAN MARTINELECTRICAL:ELECTRICAL DESIGN, INC.9565 WAPLES STREET, SUITE 205SAN DIEGO, CA 92121TEL: (858) 869-8747CONTACT: EDDIE DAVIDCIVIL:THE ALTUM GROUP73-710 FRED WARING DRIVE, SUITE 219PALM DESERT, CA 92260TEL: (760) 346-4750CONTACT: JAMES BAZUALANDSCAPE:RGA LANDSCAPE ARCHITECTS, INC.73061 EL PASEO, SUITE 210PALM DESERT, CA 92260TEL: (760) 568-3624CONTACT: ROB PARKEROWNER'S REPRESENTATIVE:TALL MAN GROUP9548 VISTA ALETAVALLEY CENTER, CA 92082TEL: (760) 749-6669CONTACT: JON MCMILLEN#-------REVISIONDATELA QUINTA, CA 922038-6284JEFF RODGERSLUIS OCHOA06/12/201842-800 WASHINGTON STCL T ILERFEFYETASOFIHA INIC.&OWLVGE I LCPSEA ISTS y s t e m s I n c.FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS HCIONTARIO SAN DIEGO IRVINE HAYWARDPhone: (858) 560-7000Fax: (858) 560-700724-Hour Service:(877) 331-2084Website:www.hcisystems.netSan Diego Office:4585 Murphy Canyon RoadSan Diego, CA 92123BURBANK FRESNO SACRAMENTOWASHINGTONSTREETAPARTMENTSFIRE ALARM SUBMITTAL06/12/18SPRINKLERMONITORING SYSTEMCOVER PAGEAS NOTEDFA-001 JS EXISTING BUILDING A(8-UNITS)EXISTINGBUILDING B(8-UNITS)EXISTINGBUILDING C(8-UNITS)EXISTINGBUILDING D(8-UNITS)EXISTING BUILDING E(8-UNITS)EXISTINGBUILDING F(8-UNITS)W/ EXISTINGLAUNDRYROOMEXISTING BUILDING J(8-UNITS)EXISTINGBUILDING H(8-UNITS)EXISTINGBUILDING G(8-UNITS)RPLAZAPER LANDSCAPECOURTYARDPER LANDSCAPECOURTYARDPER LANDSCAPENEW BUILDING K(5 UNITS)NEW BUILDING L(8 UNITS)NEW BUILDING M(7 UNITS)NEW BUILDING N(6 UNITS)LCOMMONSRETENTION BASINPER LANDSCAPEHIDDEN RIVER ROAD WASHINGTON STREETT T LAUNDRYTRPOOLMAINT.OFFICESPATPhase 215HC 1HC 2614152344HC 7HC 849HC 3HC 4HC 5HC 62429303334373843455054HC 9HC 105563HC 11HC 126470(UNDER SEPARATE PERMIT)DRIVE AISLEDRIVE AISLEDRIVE AISLE DRIVE AISLE BFPBFPUUPHASE 1 - UNDER SEPARATE PERMIT3'4'3'4'3'3'LNGCOMMONSLAUNDRYMAINT.NEW BUILDING O(7 UNITS)NEW BUILDING P(8 UNITS)NEW BUILDING Q(6 UNITS)NEW BUILDING R(8 UNITS)NEW BUILDING S(6 UNITS)NEW BUILDING T(7 UNITS)RETENTION BASINPER LANDSCAPERETENTION BASINPER LANDSCAPEBFPU#-------REVISIONDATELA QUINTA, CA 922038-6284JEFF RODGERSLUIS OCHOA06/12/201842-800 WASHINGTON STCL T ILERFEFYETASOFIHA INIC.&OWLVGE I LCPSEA ISTS y s t e m s I n c.FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS HCIONTARIO SAN DIEGO IRVINE HAYWARDPhone: (858) 560-7000Fax: (858) 560-700724-Hour Service:(877) 331-2084Website:www.hcisystems.netSan Diego Office:4585 Murphy Canyon RoadSan Diego, CA 92123BURBANK FRESNO SACRAMENTOWASHINGTONSTREETAPARTMENTSFIRE ALARM SUBMITTAL06/12/18SPRINKLERMONITORING SYSTEMFIRE ALARM SYSTEM - OVERALL SITE PLAN - PHASE 2SCALE:1/32" = 1'-0"OVERALLSITE PLANAS NOTEDFA-100NORTHFIRE ALARM AND BOOSTER PANEL SHALL BE TO ADEDICATED 120VAC PROTECTED POWER SOURCE.THE DEDICATED BREAKER SHALL BE CLEARLYLABELED AT THE DISCONNECT, IN RED, "FIREALARM". SUCH DISCONNECTS SHALL BEACCESSIBLE ONLY TO AUTHORIZED PERSONNEL.SHEET NOTESDESCRIPTIONSYMBOL1FIELD VERIFY EXACT LOCATION.2DESCRIPTIONSYMBOLDEVICE LEGENDFIRE ALARM CONTROL PANELFACPDUAL INPUT MODULEAIMDPLUG-IN COMMUNICATOR INTERFACExxCD = CANDELA RATINGxW = SPEAKER TAP WATTAGEEOL = END OF LINEFBO = FURNISHED BY OTHERSWP = WEATHER PROOF DEVICEINTELLIGENT PHOTOELECTRIC SMOKE DETECTORSPMANUAL PULL STATIONFFIRE ALARM TERMINAL CABINETFATCWATER FLOW SWITCH/TAMPER SWITCHWFTSBACKFLOW PREVENTORBFPPOST INDICATING VALVEPIVFIRE ALARM DOCUMENT CABINETFADFIRE ALARM CELLULAR ALARM COMMUNICATORCELLMONITOR MODULE FOR BFP AND PIV.3FIRE ALARM SYSTEM - OVERALL SITE PLAN - PHASE 1 & 2SCALE:NORTH1/32" = 1'-0" ElectricalClosetFire Closet1303 SFUnit K-01685 SFUnit K-03681 SFUnit K-02685 SFUnit K-04698 SFUnit K-05FATCCELLFACPAIMDSPFWFTSAIMDFAD12ElectricalClosetFire ClosetStorageCloset702 SFUnit L-01685 SFUnit L-02685 SFUnit L-03685 SFUnit L-04685 SFUnit L-05685 SFUnit L-06685 SFUnit L-07701 SFUnit L-08FATCCELLFACPAIMDSPFWFTSAIMDFAD12ElectricalClosetFire Closet1181 SFUnit M-01685 SFUnit M-02685 SFUnit M-03685 SFUnit M-04685 SFUnit M-05685 SFUnit M-06701 SFUnit M-07FATCCELLFACPAIMDSPFWFTSAIMDFAD12Fire ClosetFATCCELLFACPAIMDSPFWFTSAIMDFADAIMDOUT TO BFPU123#-------REVISIONDATELA QUINTA, CA 922038-6284JEFF RODGERSLUIS OCHOA06/12/201842-800 WASHINGTON STCL T ILERFEFYETASOFIHA INIC.&OWLVGE I LCPSEA ISTS y s t e m s I n c.FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS HCIONTARIO SAN DIEGO IRVINE HAYWARDPhone: (858) 560-7000Fax: (858) 560-700724-Hour Service:(877) 331-2084Website:www.hcisystems.netSan Diego Office:4585 Murphy Canyon RoadSan Diego, CA 92123BURBANK FRESNO SACRAMENTOWASHINGTONSTREETAPARTMENTSFIRE ALARM SUBMITTAL06/12/18SPRINKLERMONITORING SYSTEMSCALE:1/8" = 1'-0"NORTHBUILDINGSK,L,M,P,RFLOOR PLANSAS NOTEDFA-101FIRE ALARM AND BOOSTER PANEL SHALL BE TO ADEDICATED 120VAC PROTECTED POWER SOURCE.THE DEDICATED BREAKER SHALL BE CLEARLYLABELED AT THE DISCONNECT, IN RED, "FIREALARM". SUCH DISCONNECTS SHALL BEACCESSIBLE ONLY TO AUTHORIZED PERSONNEL.SHEET NOTESDESCRIPTIONSYMBOL1FIELD VERIFY EXACT LOCATION.2DESCRIPTIONSYMBOLDEVICE LEGENDFIRE ALARM CONTROL PANELFACPDUAL INPUT MODULEAIMDPLUG-IN COMMUNICATOR INTERFACExxCD = CANDELA RATINGxW = SPEAKER TAP WATTAGEEOL = END OF LINEFBO = FURNISHED BY OTHERSWP = WEATHER PROOF DEVICEINTELLIGENT PHOTOELECTRIC SMOKE DETECTORSPMANUAL PULL STATIONFFIRE ALARM TERMINAL CABINETFATCWATER FLOW SWITCH/TAMPER SWITCHWFTSBACKFLOW PREVENTORBFPPOST INDICATING VALVEPIVFIRE ALARM DOCUMENT CABINETFADFIRE ALARM CELLULAR ALARM COMMUNICATORCELLMONITOR MODULE FOR BFP AND PIV.3FIRE ALARM SYSTEM - LEVEL 1 - FLOOR PLAN - BUILDING K (NEW)SCALE:1/8" = 1'-0"NORTHFIRE ALARM SYSTEM - LEVEL 1 - FLOOR PLAN - BUILDINGS L,P,R (NEW)SCALE:1/8" = 1'-0"NORTHFIRE ALARM SYSTEM - LEVEL 1 - FLOOR PLAN - BUILDING M (NEW)SCALE:1/8" = 1'-0"BUILDINGS K,L,PNORTHBUILDINGS OUT TO BFP ElectricalClosetFire ClosetStorage701 SFUnit N-01685 SFUnit N-02685 SFUnit N-03685 SFUnit N-04685 SFUnit N-05701 SFUnit N-06FATCCELLFACPAIMDSPFWFTSAIMDFAD12ElectricalClosetFire ClosetStorageCloset702 SFUnit O-01685 SFUnit O-02685 SFUnit O-03685 SFUnit O-05685 SFUnit O-06701 SFUnit O-07685 SFUnit O-04FATCCELLFACPAIMDSPFWFTSAIMDFAD12DW REF.FitnessMechanicalRestroom1Restroom2OfficeKitchenMailHallLoungeMulti-PurposeRoomPoolEquip.OutdoorShowersCoveredPool AreaComputerLoungeFATCCELLFACPAIMDSPFWFTSAIMDFAD12Multi-PurposeRoomWashroomComputerLoungeTherapyRoomKitchenFitnessGrottoOfficeEntry HallPlumbing/FireElectricalStorageWashroomFATCCELLFACPAIMDSPFWFTSAIMDFAD12DWWWWWWWWWWWWDDDDDD WWOutdoor LoungeLaundryRoomMaintenanceRoomMaintenanceRoomLaundryRoomLounge#-------REVISIONDATELA QUINTA, CA 922038-6284JEFF RODGERSLUIS OCHOA06/12/201842-800 WASHINGTON STCL T ILERFEFYETASOFIHA INIC.&OWLVGE I LCPSEA ISTS y s t e m s I n c.FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS HCIONTARIO SAN DIEGO IRVINE HAYWARDPhone: (858) 560-7000Fax: (858) 560-700724-Hour Service:(877) 331-2084Website:www.hcisystems.netSan Diego Office:4585 Murphy Canyon RoadSan Diego, CA 92123BURBANK FRESNO SACRAMENTOWASHINGTONSTREETAPARTMENTSFIRE ALARM SUBMITTAL06/12/18SPRINKLERMONITORING SYSTEMSCALE:1/8" = 1'-0"NORTHBUILDINGSN,O,Q,R,T, & COMMONSFLOOR PLANSAS NOTEDFA-102FIRE ALARM AND BOOSTER PANEL SHALL BE TO ADEDICATED 120VAC PROTECTED POWER SOURCE.THE DEDICATED BREAKER SHALL BE CLEARLYLABELED AT THE DISCONNECT, IN RED, "FIREALARM". SUCH DISCONNECTS SHALL BEACCESSIBLE ONLY TO AUTHORIZED PERSONNEL.SHEET NOTESDESCRIPTIONSYMBOL1FIELD VERIFY EXACT LOCATION.2DESCRIPTIONSYMBOLDEVICE LEGENDFIRE ALARM CONTROL PANELFACPDUAL INPUT MODULEAIMDPLUG-IN COMMUNICATOR INTERFACExxCD = CANDELA RATINGxW = SPEAKER TAP WATTAGEEOL = END OF LINEFBO = FURNISHED BY OTHERSWP = WEATHER PROOF DEVICEINTELLIGENT PHOTOELECTRIC SMOKE DETECTORSPMANUAL PULL STATIONFFIRE ALARM TERMINAL CABINETFATCWATER FLOW SWITCH/TAMPER SWITCHWFTSBACKFLOW PREVENTORBFPPOST INDICATING VALVEPIVFIRE ALARM DOCUMENT CABINETFADFIRE ALARM CELLULAR ALARM COMMUNICATORCELLMONITOR MODULE FOR BFP AND PIV.3FIRE ALARM SYSTEM - LEVEL 1 - FLOOR PLAN - BUILDINGS N,Q,S (NEW)FIRE ALARM SYSTEM - LEVEL 1 - FLOOR PLAN - BUILDINGS O,T (NEW)SCALE:1/8" = 1'-0"NORTHSCALE:1/8" = 1'-0"NORTHSCALE:1/8" = 1'-0"NORTHFIRE ALARM SYSTEM - LEVEL 1 - FLOOR PLAN - COMMON BUILDINGS - PHASE 1FIRE ALARM SYSTEM - LEVEL 1 - FLOOR PLAN - COMMON BUILDINGS - PHASE 2*THIS BUILDING DOES NOT REQUIRE SPRINKLER MONITORING SINCE NO SPRINKLER SYSTEM OR LESS THAN 20 SPRINKLER HEADS*THIS BUILDING DOES NOT REQUIRE SPRINKLER MONITORING SINCE NO SPRINKLER SYSTEM OR LESS THAN 20 SPRINKLER HEADS FIRE ALARM CONTROL PANEL (FPD-7024) W/ CELL COMMUNICATOR & NEMA 3R ENCLOSURE AND CALCULATIONS#History0*D7024CONNECT EARTHGROUND TOTHREADED GROUNDSTUD ON LEFT SIDE OFENCLOSURE.CONNECT PRIMARYSIDE OFTRANSFORMERTO 120V, 60HZCIRCUIT USINGWIRE NUTS.ClearProgCmndSYSTEM NORMALBOSCH D7024741SilenceDisable9856TestReset23DrillALARMPOWERTROUBLESILENCEDSWITCHEDSMOKE POWERD7034CONNECTORONLYB450 CELLULARINTERFACE MODULEB440 PLUG-INCELLULAR DIALERAUXILIARY RELAYNAC1+NAC1-NAC2+NAC2-BAT-BAT+AC POWER3AC POWERNCAC POWER1AUXILIARY RELAY120VAC DEDICATEDCIRCUIT BY E.C.NEMA 3R ENCLOSURE FACP CABINET INTERIOR DETAIL12 VDC BATTERY, 18 A.H.+-+-12 VDC BATTERY, 18 A.H.FPD-7024 SMP INTERIOR DETAILSCALE:NONECALLOUT - DESCRIPTION1. EOL RESISTOR2. INPUT ZONE 13. INPUT ZONE 24. ZONE IN (+)5. ZONE IN (-)CLASS "B" WIRING CONNECTIONSLOOP AND CONTROL PANEL WIRING CONNECTIONSCALLOUT - DESCRIPTION1. CLASS "A" & CLASS "B" JUMPER PINS2. CLASS "B"3. CLASS "A"4. MUX BUS LOOP (+)5. MUX BUS LOOP (-)6. DATA OUT7. DATA IN FROM D70391. MOUNTING HOLES FOR THE D7050-B6 TO THE ADAPTER PLATE.2. MOUNTING HOLES FOR THE D7050-B6 TO THE OCTAGON BOX.3. MOUNTING HOLES FOR THE D7050-B6 TO THE ADAPTER PLATE. (USE 6-32 X 1 IN. SCREWS.)WIRING:1. IN FROM PREVIOUS DEVICE OR D7039.2. LOOP (+).3. LOOP (-).4. TO OTHER DEVICES.MOUNTING:THE FMM-7045 MANUAL STATIONS FLUSH OR SURFACEMOUNT ON A STANDARD FOOR-INCH SQUARE BOXWITH A SINGLE-GANG MUD RING SO THAT THE TOTALDEPTH OF THE BOX IS AT LEAST 2.25 IN. (5.7 CM).CALLOUT ― DESCRIPTION1. MODULE HANDLE AND SUPPORT LEG2. LEDS3. THREADED FEMALE SMA ANTENNA CONNECTOR4. PLUG-IN MODULE RETENTION CLIP OPENING5. PCB METAL CONTACTS123451CALLOUT ― DESCRIPTION:1. ANTENNA ROUTED THROUGH ANY KNOCK-OUT- USEHONEYWELL GSM3DB25KT2. ANTENNA CABLE CONNECTED TO THE MODULECALLOUT ― DESCRIPTION:1. SUPPORT LEG INSERTED INTO THE CONTROL PANELSUPPORT HOLE LABELED X2. PCB METAL CONTACTS RESTING ON THE ON-BOARDCONNECTOR3. PLUG-IN MODULE RETENTION CLIPD7052: DUAL INPUT MODULENOT TO SCALEDEVICE DETAIL:D7050-B6 DETECTOR BASENOT TO SCALEDEVICE DETAIL:FMM-7045 MANUAL PULL STATIONNOT TO SCALEDEVICE DETAIL:D7052: DUAL INPUT MODULENOT TO SCALEDEVICE DETAIL:B450 CONETTIX CELL COMMUNICATORNOT TO SCALEDEVICE DETAIL:DSC LE4010CFNOT TO SCALEDEVICE DETAIL:SCALE:NONEBUILDINGS K,L,P ONLY - FACP CALCULATIONS#-------REVISIONDATELA QUINTA, CA 922038-6284JEFF RODGERSLUIS OCHOA06/12/201842-800 WASHINGTON STCL T ILERFEFYETASOFIHA INIC.&OWLVGE I LCPSEA ISTS y s t e m s I n c.FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS HCIONTARIO SAN DIEGO IRVINE HAYWARDPhone: (858) 560-7000Fax: (858) 560-700724-Hour Service:(877) 331-2084Website:www.hcisystems.netSan Diego Office:4585 Murphy Canyon RoadSan Diego, CA 92123BURBANK FRESNO SACRAMENTOWASHINGTONSTREETAPARTMENTSFIRE ALARM SUBMITTAL06/12/18SPRINKLERMONITORING SYSTEMPANEL DETAILSAND CALCULATIONSAS NOTEDFA-701 FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for : Washington Street Apartments 42-800 WASHINGTON STREET, LA QUINTA, CA 92203 Ontario ● San Diego ● Irvine ● Hayward ● Burbank ● Fresno ● Sacramento Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (909) 628-7773 FAX: (909) 628-7774 24-Hour Service: (877) 331-2084 Website: www.hcisystems.net S y s t e m s I n c. HCI Washington Street Apartments 42-800 WASHINGTON STREET, LA QUINTA, CA 92203 Manufacturer Device Model #Description C.S.F.M. # BOSCH FPD 7024 Fire Alarm Control Panel 7165-1615:0227 BOSCH B450 Fire Alarm Cellular Alarm Communicator Module 7165-1615:0227 DSC LE4010CF-AT Fire Alarm Cellular Alarm Communicator 7300-1273:0505 SPACE AGE ACE-11 Fire Alarm Document Cabinet 7300-0553:0110 BOSCH FMM-7045 Manual Pull Station 7150-1615:0122 BOSCH D263 Photoelectric Smoke Detector 7272-1615:0134 BOSCH D7052 Dual Input Module 7165-1615:0227 Fire Alarm Systems | FPD-7024 Family Fire alarm control panels FPD-7024 Family Fire alarm control panels www.boschsecurity.com u Four initiating zones (expandable to eight) with up to 20 two‑wire smoke detectors per zone u Programmable through keypads or remote programming software (RPS) through a Conettix interface module or over the public switched telephone network (PSTN) u Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply u Easily converts to addressable with the addition of a MUX expansion module u Reports to two phone numbers, two IP addresses, or a phone number and an IP address The FPD‑7024 Family FACPs can be used in commercial, retail, and public building applications. They are listed by UL for central station, local, auxiliary, and remote station systems. The FACPs support four on‑board initiating zones that can be expanded to eight using the FPC‑7034 Four‑point expander. Each initiating zone supports two‑wire and four‑wire detectors configurable as Class A or Class B loops. Each zone can support up to 20 two‑wire detectors, or any number of four‑wire detectors depending on available power. Each FACP has a built‑in digital fire alarm communicator transmitter (DACT). Enhance the FPD‑7024 conventional system features by adding an FPE-7039 or D7039 MUX expansion module. Adding a MUX expansion module to the FACP turns the conventional FACP into an addressable FACP. The MUX expansion module adds up to 247 addressable points to the base system. It also adds an additional 400 events to the history buffer for a total of 499 events. The module increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. The FPE-7039 allows you to use FPE-7024-ISO MUX bus isolator modules. The isolator modules prevent failure of the entire bus when there is a short on the bus. Functions Notification Appliance Circuits Two Class A or Class B NACs provide regulated power to operate notification appliances. Each NAC can be programmed to provide synchronized output for Wheelock, Gentex, or System Sensor notification appliances. The available outputs are: • Temporal Code 3 • California March • Steady • Pulsed User Interface A viewing port shows the status light‑emitting diodes (LEDs) and liquid‑crystal display (LCD) while maintaining system keypad security. For multi‑language applications, the status LEDs and keypad buttons are labeled with symbols. The display can be in US English, Latin-American Spanish, or Brazilian Portuguese. Unlocking the enclosure door provides access to the system controls for: • Silencing off‑normal conditions • Bypassing zones • Resetting detectors • Testing • Programming • Other fire functions Two additional keypads (FMR‑7033 LCD keypad and FMR-7036 Fire annunciator keypad) mimic the panel’s built‑in keypad. Wherever the FMR‑7033 is connected to the system, it makes all the functions of the built‑in keypad available. The FMR-7036 provides the status LEDs and display (in any of the three available languages). The key‑locked buttons provide access only to reset, scroll, and silence functions. Organized Event Display The software sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. History Buffer The system stores events in a 99‑event history buffer. Notice A MUX expansion module increases the number of events that can be stored in the history buffer to 499. Central Station Reporting The FPD-7024 FACPs uses account numbers up to 10 digits to send reports. It can send reports with full single, double, and backup reporting. It can send reports to two telephone numbers, one telephone number and one IP address, or two IP addresses. Notice IP use requires a Conettix interface module at the panel and an appropriate Conettix receiver at the central station. The panel supports communication in BFSK, SIA, Contact ID, Modem IIIa2, and 4/2 or 3/1 Tone Burst formats. Dirty Detector Monitoring All on‑board zones and FPC‑7034 zones are continuously monitored for smoke detectors signaling a dirty condition. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. If the calibration is out of range, the detector’s LED flashes once every 4 seconds. This indicates that the detector must be cleaned following the instructions provided with the detector. Also, the control panel annunciates that there is a dirty detector on the loop or the address. For detectors on a two-wire loop, it the detector’s smoke chamber is dirty, the detector sends a CleanMe signal. For detectors on an addressable loop, the detector sends a dirty detector signal. Accessories The FPD‑7024 enclosure (P/N: F01U068852) has a viewport for keypad messages while the enclosure door is locked. It also has space for additional accessory modules and two 18 Ah batteries. The BATB‑40 or BATB-80 Battery box/enclosures accommodate larger batteries or additional batteries. Notice Notice! The panel can handle batteries up to 40 Ah. When selecting batteries, ensure that the batteries can handle an initial charge current of at least 1.7 A. Certifications and approvals Region Certification USA UL ANSI/UL 864, Control Units and Acces-sories for Fire Alarm Systems (10th edi-tion) FM see the FM Approval Guide CSFM see our website FCC ESVAL04B7024 FDNY-CoA 6173 Installation/configuration notes Compatible Products The following products are compatible (refer to the product datasheet for country‑specific certifications/ approvals) with the FACPs: Category Product ID and Description Batteries and Power Supplies D126 12 V, 7 Ah battery D1218 12 V, 18 Ah battery FPP‑RNAC‑8A‑4C Remote NAC power supply BATB-40 Battery box/enclosure BATB-80 Battery box/enclosure with shelf Detectors For two‑wire detector compatibility, refer to the FPD‑7024 Smoke Detector Compatibility List Keypads and Annunciators D7030X Eight‑point LED annunciator (eight red) D7030X‑S2 Eight‑point LED annunciator (two yellow, six red) D7030X‑S8 Eight‑point LED annunciator (eight yellow) 2 | FPD-7024 Family Fire alarm control panels D7032 Eight‑point LED annunciator expander (eight red) FMR‑7033 LCD fire system keypad FMR‑7036 LCD annunciator Modules D132B Smoke detector reversing relay module D185 Reversing polarity module D275 EOL power supervision module D7039 Multiplex expansion module FPC‑7034 Four‑point expander FPE-7039 Multiplex expansion module Option Bus Devices B420 Ethernet communicator B426 Ethernet communication module B440 Conettix plug‑in cellular B441 Conettix plug‑in cellular B442 Conettix plug‑in GPRS cellular B443 Conettix plug‑in HSPA+ cellular B450 Conettix plug‑in communicator interface D7035 Octal relay module D7035B Octal relay module in box DX4010V2 USB/serial interface module DX4020 Network interface module ITS-DX4020-G GPRS/GSM communicator NAC Devices Refer to the FPD‑7024 Device Compatibility List The following additional products are compatible with the Addressable FACPs: Category Product ID and Description Detector Heads and Bases D7050 Addressable photoelectric smoke detector head D7050TH Addressable photoelectric smoke and heat detector head D7050‑B6 Detector base Modules D7042 Multiplex eight‑input remote module D7042B Multiplex eight‑input remote module in box D7044 Multiplex single‑input module D7044M Mini multiplex single‑input module D7048 Octal driver module D7052 Multiplex dual‑input module D7053 Multiplex input‑output module FLM-7024-ISO MUX bus isolator module* Pull Stations FMM‑7045 Single‑action manual station FMM‑7045‑D Double‑action manual station * Requires FPE-7039 MUX expansion module Technical specifications Electrical Line impedance for ground fault detection (Option Bus, conventional input, NAC, secondary power circuit, MUX Bus, AUX power, SMK power) 10 kΩ or less Power (non-resettable Input)120 V 60 Hz 1.4 A or 230/240 V 50 Hz, 0.7 A Power (non‑resettable Auxiliary)17 to 31 VRMS, unfiltered, 1.0 A Power (resettable Smoke)1 20.4 to 28.2 VDC nominal, filtered, 1.0 A. Power (Option Bus)12 VDC nominal, 500 mA Power (Notification Appliance Circuit [NAC])2 Each NAC has 24 VRMS nominal, unfiltered power with up to 2.5 A capacity (but limited by the panel’s overall 4.0 A capacity) Power (Optional Standby Batteries) Two 12 V (in series), 7 Ah to 40 Ah NACs Line Impedance (voltage loss) 1.5 V Recommended battery manufacturers3 Power Sonic: PS-1270, PS-12170, PS-12180 YUASA: NP7-12, NPG18-12 1 For compatible smoke detection devices, see also the FPD‑7024 Smoke Detector Compatibility List. 2 For compatible NAC devices, see also the FPD‑7024 NAC Compatibility List 3 If other manufacturers or battery types are used, ensure that the battery or batteries can handle an initial charge current of at least 1.7 A. Environmental Temperature (operating and storage) +32°F to +120°F (0°C to +49°C) Notification Appliance Circuits Wiring Class B or Class A Notification patterns Configurable for steady, pulsing, California March, Temporal (ANSI) code 3, synchronized Wheelock, synchronized Gentex, and synchronized System Sensor. 3 | FPD-7024 Family Fire alarm control panels Relays Local (on- board) The main control panel includes Three Form C relays. The relay contacts are rated at 5 A, 28 VDC. No over current limiting is performed on the contacts of the relays. The default selection for the relays is to indicate general alarm (relay 1), general system trouble (relay 2), and supervisory (relay 3). By using point or zone mapping, they can be programmed to activate in a wide variety of conditions. Remote1 Eight Form C relay outputs are provided by a D7035 Remote Relay Module. The module connects to the FACP through the option bus. The outputs are fully programmable, exactly as the local relays are programmed. Each output operates independently of the other seven to provide complete flexibility. Communication with the D7035 is supervised. Contact Rating: 5 A at 28 VDC Number of Modules: two units maximum. 1 For wiring requirements, see Option bus wiring requirements. Trademarks All hardware/software product names used in this document are likely to be registered trademarks and must be treated accordingly. Ordering information FPD-7024 FACP 4-zone 24V, red enclosure It has four detector zones (expandable to eight) with up to 20 two-wire smoke detectors per zone. It has two NACs on board with a shared internally-regulated 24 VFWR, 4 A NAC power supply. It communicates over phone or IP communication circuits. Order number FPD-7024 FPD-7024-LC FACP 4-zone 24V, w/o enclosure Four detector zones (expandable to eight) with up to 20 two wire smoke detectors per zone Order number FPD-7024-LC Accessories FPD-7024-LT 4 ZONE 24V FACP LESS XFMR Four detector zones (expandable to eight) with up to 20 two wire smoke detectors per zone. Available only in Latin America. Order number FPD-7024-LT D102 Replacement Key The D102 is a replacement key for locks stamped with 1358. Order number D102 4 | FPD-7024 Family Fire alarm control panels 5 | FPD-7024 Family Fire alarm control panels Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2017 | Data subject to change without notice 18736331915 | en, V7, 05. Jan 2017 Intrusion Alarm Systems | B450 Conettix Plug-in Communicator Interface B450 Conettix Plug-in Communicator Interface www.boschsecurity.com u Enables full two-way IP communication using Plug-in Cellular Communicators u Plug and Play installation makes future radio technology changes easy u Compatible with new and most deployed Bosch control panels u Supports remote installation of cellular modules for improved signal The B450 Conettix Plug-in Communicator Interface is a four-wire powered SDI2, SDI, or option bus device that provides two-way communication with compatible control panels over commercial cellular networks using a plug-in communicator (available separately). System overview Use B450 in combination with a plug-in communicator for primary or backup alarm communication, remote panel programming and other remote applications. The B450 supports Conettix IP protocol with full authentication, 256 bit AES encryption and resistance to Denial of Service attacks. It is a reliable way to add cellular network communications to existing or new commercial security and fire installations. 1 2 7 5 6 3 4 13 12 11 8 14 9 10 B450 system overview Callout ᅳ Description Callout ᅳ Description 1 ᅳ Compatible Bosch control panel 6 ᅳ Cellular carrier network 2 ᅳ Panel data bus (SDI2, SDI, or Option) 7 ᅳ Internet/LAN/WAN 3 ᅳ B450 Plug-in Communicator Interface 8 ᅳ Remote Programming Workstation 4 ᅳ USB connection for B450 configuration 9 ᅳ Bosch Conettix IP receiver (D6600, D6100i, or D6100IPv6) 5 ᅳ B44x Plug-in Cellular Communicator (available separately) Functions Conettix IP communication The B450 uses Conettix IP protocol which supports: • Full event code reporting and administration • Flexible supervision intervals • Resistance to Denial of Service attacks • 128, 192 or 256-bit AES encryption • Anti-replay and anti-substitution Switch addressing Use the address switch to easily assign a bus address or setup for USB or SMS configuration where required. Easy configuration For most installations, the default B450 settings allow installation with no device programming required. An address switch allows easy bus address selection. For customized network settings, the B450 supports a USB configuration menu, or configuration via SMS. B Series and GV4 Series control panels support limited keypad and RPS programming of B450 settings. LEDs Three LEDs provide status and troubleshooting information about the module and its connection. LED Description Heartbeat Indicates the system status of the B450 and its connection to the panel. RX Indicates when an inbound packet is received on the bus. TX Indicates when an outbound packet is transmitted on the bus. Certifications and approvals Region US NIST FIPS 197 FCC Part 15 Class B UL 365 UL 636 UL 864 UL985 UL 1023 UL 1076 UL 1610 SIA CP-01:2010 False Alarm Reduction California State Fire Marshall (CSFM) - Certified Fire Department of New York (FDNY) - Certified Canada CAN/ULC S303 CAN/ULC S304 ULC S545 ULC-ORD C1023 ULC-ORD C1076 ICES-003 – Digital Apparatus Rogers - Certified North America PTCRB - Certified Europe CE - EN50130-4, EN61000-6-3, EN60950 Australia A-tick - Certified Region Certification Europe CE 2014/30/EU EMC Directive (EMC);2014/35/EU Low-Voltage Directive(LVD); 2011/65/EU Restriction of theuse of certain hazardous substances inelectrical and electronic equip-ment(RoHS) USA CSFM see our website FDNY-CoA #6173 Brazil ANATEL 2708-14-1855 Installation/configuration notes Mounting considerations Find a location with acceptable signal strength on your wireless network. Mount the B450 Conettix Plug-in Communicator Interface into the interior of a compatible enclosure via the 3-hole mounting pattern using the supplied mounting screws. Wiring considerations The B450 connects to a control panel using a data bus connection via the module’s terminal strip, or the module’s interconnect wiring connectors. For data bus powered installations outside the compatible control panel enclosure, follow the maximum wiring distances in the technical specifications. For further installations power from a compatible auxiliary power supply. Parts included Quantity Component 1 B450 Conettix Plug-in Communicator Interface 1 Hardware pack 1 Interconnect cable wiring 2 | B450 Conettix Plug-in Communicator Interface 1 Quick Start Guide (hardcopy) 1 Literature (mini-CD) Technical specifications Electrical Current (operating) Standby: B450 with B440/B441/B442/B443 = 60 mA Alarm: B450 with B440/B441/B442/B443 = 180 mA Voltage (operating)(B450 bus operation): 12 VDC nominal Environmental Relative humidity Up to 93% at +32°C (+90°F) non-condensing Operating temperature 0°C to +50°C (+32°F to +122°F) Mechanical Board dimensions 79 mm x 128 mm x 38 mm (3.11 in x 5.03 in x 1.50 in) Wiring Data bus wire gauge 12 AWG to 22 AWG USB cable USB cable (Type A to A male-to-male) – not supplied Data bus wire length Maximum Distance – wire size: 22 AWG (0.65 mm) --> 12 m (40 ft) 18 AWG (1.0 mm) --> 30 m (100 ft) 16 AWG (1.3 mm) --> 48 m (158 ft) 12 AWG (2.0 mm) --> 122 m (400 ft) Using a separate power supply, such as the B520 Auxiliary Power Supply Module , connected to the B450 within the specification listed above, the wire distance can be extended up to 300 m (1000 ft) Compatibilities Control panels B5512/B4512/B3512 (B5512E/B4512E/ B3512E with firmware v2.03 and higher) D9412GV4/D7412GV4/D7212GV4 (v1.00.0xx+) D9412GV3/D7412GV3/D7212GV3 D9412GV2/D7412GV2/7212GV2 (v7.06+) FPD-7024 (v1.03+) AMAX 2000/2100/3000/4000 CMS 6/8 CMS 40 Solution 2000/3000 Cellular communicators B440 Conettix Plug-in Communicator, Cellular (3G) B441 Conettix Plug-in CDMA Cellular Communicator B442 Conettix Plug-in GPRS Cellular Communicator B443 Conettix Plug-in HSPA+ Cellular Communicator Enclosures B10 B11 D8103 D203 Applications Tera Term (for USB B450 configuration) Hyper Terminal (for USB B450 configuration) RPS version 5.16 or higher Installed Bus Function Option/SDI SDI2 Details IP Event Reporting Y Y TCP protocols only supported on SDI2 Remote Program (RPS or A-link) Y Y Requires Bosch Cellular service or other cellular network access Configure B450 from control panel (RPS, A-link) N Y GV4/B Series v2.03+, AMAX vX.X, Solution vX.X Personal Notification via SMS or Email N Y Requires compatible control panel and cellular plan Remote Security Control App N Y*Requires Bosch Cellular service or other cellular network access Ordering information B450 Conettix Plug-in Communicator Interface Supports two-way IP communication over using a plug- in Cellular Communicator for compatible SDI2, SDI or option bus control panels. Order number B450 Accessories B440 Conettix Plug-in Cellular Communicator Dual technology 3G EVDO/CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Order number B440 B441 Conettix Plug-in Cellular Communicator Multi-function CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Order number B441 B442 Conettix Plug-in GPRS Cellular Communicator Multi-function cellular communicator. For use in Latin America. Order number B442 3 | B450 Conettix Plug-in Communicator Interface B443 Conettix Plug-in HSPA+ Cellular Communicator Multi-function 3G/4G cellular communicator providing IP communication over a GSM/GPRS/EDGE/UMTS/ HSPA+ cellular network. For use in Latin America and Canada. Order number B443 4 | B450 Conettix Plug-in Communicator Interface Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2014 | Data subject to change without notice 11036186251 | en, V16, 04. Nov 2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7165-1615:0227 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterflow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033, FMR-7036; Keypad D7035, D7035B; Expanded Relay Module D185; Reverse Polarity Module D7039, *FPE-7039; MUX Expander D7042, D7042B, D7044, D7044M, D7052, D7053; Mulitplez Expander Module D7048, D7048B; Octal Driver Module B440, B441, B443; Cellular Modules B450; Interface Module *FLM-7024-ISO; MUX Bus Isolator Module RATING:120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee’s printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee’s name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee’s Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Revsion 02-15-17 gt July 19, 2018Date Issued:Listing Expires June 30, 2019 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator communications Features That Make a Difference: • Uses LTE network for high- speed, reliable and low-cost communications to an IP receiver • Automatically switches to 3G (HSPA/HSPA+) if LTE service is not available • Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats • Full event reporting • 4 on-board inputs with NC, NO or SEOL supervision • 4 on-board outputs (open collector) • Activation and initialization via website or mobile interface provided by C24 Communications • View communicator status directly from your mobile phone to support on-site or remote troubleshooting • Compatible with Sur-Gard® System I-IP/II/III/IV/5 monitoring station receivers • Includes UL listed power supply, transformer and 7 Ah rechargeable battery • UL 864 listed • CSFM listed Due to rapidly-evolving cellular technologies, 2G/3G network sunsets are already on the horizon – with some having already been completed. Now’s the time to adopt and adapt. Switch to LTE today, to offer customers long-lasting investment protection, and reduce your future truck rolls. The LE4010CF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System I-IP/II/III/IV/5). The LE4010CF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The LE4010CF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010, 2013, and 2016 editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013/2016) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The LE4010CF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the LE4010CF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. Contact your DSC distributor. www.dsc.com | 1-888-888-7838 LTE Universal Wireless Commercial Fire Alarm Communicator LE4010CF Ensure your installations are future-ready, with LTE communicationsPN 30002468In instances where the control panel does not support Contact ID or SIA (300 baud), the LE4010CF has inputs pre- set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-Gard® System I-IP/II/III/IV/5). Activating & Initializing the Unit Activating and initializing the LE4010CF can be done using the website interface provided by C24 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. UL Listing The LE4010CF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the LE4010CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013/2016 guidelines the LE4010CF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the LE4010CF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The LE4010CF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the LE4010CF requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013/2016) rate plans to support the supervision requirements. Specifications Dimensions ................................................11-1/2" x 10" x 3" (290 mm x 254 mm x 75 mm) Input Voltage.............................................................120 VAC Current Draw ..............................................200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (0° to 49° C) Weight ...........................................................12.8 lbs (5.8 kg) Optional Acessories Ordering Information: LE4010CF-AT ..............Universal Wireless Commercial Fire Alarm Communicator For product information www.dsc.com Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. ©2018 Tyco Security Products Model Description LTE-15ANT 15 ft extension antenna LTE-25ANT 25 ft extension antenna LTE-50ANT 50 ft extension antenna CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-1273:0505 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model LE4010 LTE interface. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:9-14 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee’s name, model number, electrical rating and UL label. APPROVAL: Listed as a interface for use with a separately listed fire alarm control unit. Refer to listee’s Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. 01-11-18 gt July 01, 2018Date Issued:Listing Expires June 30, 2019 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Space Age Electronics, Inc. www.1sae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax • Installed with a 4 gig digital drive with USB B connector • 2 Key ring hooks to hold system keys • Business card holder for key contacts • Overall Dimensions are 12” x 13” tall and 2 ¼ deep • 16 gauge steel box and cover for security • Durable powercoat baked on other colors available • Standard ¾”cat 30 key lock other lock as- semblies available • Solid stainless steel piano hinge • Permanently screened white ink 1” high “Fire Alarm Documents” • Legend sheet for passwords and system information Standard Features: Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. FAD NFMEMBERPA® Made In U.S.A. ACE-11 Space Age Electronics, Inc. 2008 ED0549 LT10559 Rev.D 2/2 Space Age Electronics, Inc. www.1sae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS " with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. Legend sheet for storing system information including contacts, sign-o , maintenance & test information, and alternate locations of additional records. Business Card Holder Key Ring Hooks USB Storage InterfaceRequires Standard USB-BConnector Space Age Electronics, Inc. 58 Chocksett Road Sterling, MA 01564 800-486-1723 www.1sae.com For replacement forms order P/N: EA0316 (Qty. 10) LT10644 Rev. 1 Minimum Required Documentation (SIG-FUN) (Reference NFPA-72 2013 Section 7.2.1) 1 Written narrative providing intent and system description □ N/A □ Enclosed Or Alt. Location _____________________________________________ 2 Riser diagram □ N/A □ Enclosed Or Alt. Location _____________________________________________ 3 Floor plan layout showing location of all devices and control equipment □ N/A □ Enclosed Or Alt. Location _____________________________________________ 4 Sequence of operation in either an input/ output matrix or narrative form □ N/A □ Enclosed Or Alt. Location _____________________________________________ 5 Equipment technical data sheets □ N/A □ Enclosed Or Alt. Location _____________________________________________ 6 Manufacturers published instructions, including operation and maintenance instruction □ N/A □ Enclosed Or Alt. Location _____________________________________________ 7 Battery calculations (where batteries are provided) □ N/A □ Enclosed Or Alt. Location _____________________________________________ 8 Voltage drop calculations for notification appliance circuits □ N/A □ Enclosed Or Alt. Location _____________________________________________ 9 Completed record of inspection and testing in accordance with 7.6.6 and 7.8.2 □ N/A □ Enclosed Or Alt. Location _____________________________________________ 10 Completed record of completion in accordance with 7.5.6 and 7.8.2 □ N/A □ Enclosed Or Alt. Location _____________________________________________ 11 Copy of site specific software, where applicable □ N/A □ Enclosed Or Alt. Location _____________________________________________ 12 Record (as-built) drawings □ N/A □ Enclosed Or Alt. Location _____________________________________________ 13 Periodic inspection, testing, and maintenance documentation in accordance with Section 7.6 □ N/A □ Enclosed Or Alt. Location _____________________________________________ 14 Records, record retention, and record maintenance in accordance with 7.7 □ N/A □ Enclosed Or Alt. Location _____________________________________________ Signed:_______________________ Date: ____ / ____ / ____ Property Information Name of property: ________________________ Address: ________________________________ Description of property:_____________________ Occupancy type:__________________________ Certifications and Approvals 16.1 System Installation Contractor: This system, as specified herein, has been installed and tested according to all NFPA standards cited herein. Signed:_______________________ Printed name:__________________ Date: ____ / ____ / ____ Organization:__________________ Title:_________________________ Phone: _______________________ 16.5 Authority Having Jurisdiction: I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, with its approved sequence of operations, and with all NFPA standards cited herein. Signed:_______________________ Printed name:__________________ Date: ____ / ____ / ____ Organization:__________________ Title:_________________________ Phone: _______________________ Equipment Information ID No 1: ________________________ Serial: __________________________ Access code:_____________________ ID No 2: ________________________ Serial: __________________________ Access code:_____________________ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@1sae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IF1, IFX/A and IFX/D enclosures. Models ACE-11, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee’s Installation Instruction Manual for details. 02-09-16 dc July 01, 2018Date Issued:Listing Expires June 30, 2019 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Fire Alarm Systems | FMM‑7045 Multiplex Addressable Manual Stations FMM‑7045 Multiplex Addressable Manual Stations www.boschsecurity.com u Easy addressing with rotary switches u Terminal connections and low current draw u Key‑lock reset u Replaceable scored acrylic break rod option u UL Listed and ADA compliant The FMM‑7045 Multiplex Manual Stations are UL Listed fire alarm initiating devices that can be connected along with other multiplex devices on the D7039 Multiplex Expansion Module. The FPD‑7024 or D7024 Addressable Fire Alarm Control Panel (FACP) supervises the entire multiplex loop, including the FMM‑7045 or FMM‑7045‑D manual stations, for troubles, alarms, and ground fault conditions. Because each manual station occupies only one address on the multiplex bus, it can be addressed for any point within the 9 to 255 range allowed by the multiplex expansion module. These manual stations are generally installed near building exits such as stairways and doors, allowing persons evacuating the building to activate the fire alarm. They have optional scored acrylic breakrods and a pull handle that locks in the activated position, to allow easy identification of alarm activation points. These manual stations are high‑quality units constructed entirely of non‑toxic materials. They have a low profile and rounded edges to fit most design applications. All components are painted or have plated surfaces to inhibit corrosion. Non-corroding screw terminals are provided for wire connections. They are manufactured in conformance with the standards set forth in the Americans with Disabilities Act (ADA). Functions Alarm Action The single‑action FMM‑7045 has a white pull‑down lever in its center. The dual‑action FMM‑7045‑D has a white push lever above the white pull‑down lever in its center. Pulling down the pull‑down lever latches it into place and sends an alarm signal to the control panel over the multiplex bus. The pull‑down lever cannot be reset unless the correct key is inserted into the manual station's lock and the unit is opened. The latching lever can then be restored to its normal position. Certifications and approvals Region Certification USA UL UNIU: Boxes, Non-Coded (UL38) CSFM see our website FDNY-CoA #6173 Installation/configuration notes Compatibility Information The following table lists control panels compatible with the FMM‑7045 and FMM-7045-D manual stations: Control Panels Active products: FPD-7024 Legacy products: D7024* * with firmware revision 2.0 or greater and with a D7039 Multiplex Expansion module Addressing Addresses are set using three rotary switches. For programming information, refer to the D7024 FACP Operation and Installation Guide or the FPD‑7024 Operation and Installation Guide and the FMM-7045, FMM-7045-D Multiplex Addressable Manual Stations Installation Instructions. Mounting The manual stations are for indoor use only. Notice If a pull station is needed for outdoor use or in an unheated area, use an FMM‑100 Family Pull Station rated for the environment and wired to a multiplex module within the interior of the building. The FMM‑7045 manual stations flush or surface mount on a standard four‑inch square back box with a single‑gang mud ring so that the total depth of the box is at least 2.25 in. (5.7 cm). Notice These manual stations do not fit an FMM‑100BB‑R Back Box. Wiring The terminal block accepts wiring up to 12 AWG (ISO 4 mm2) in diameter. For multiplex wiring information, refer to the D7039 Installation Instructions. Parts included Quant.Component 1 Manual station 1 FMM‑100GR Scored Acrylic Breakrod 1 D102 Key (1358) 1 Literature pack Technical specifications Environmental Considerations Environment:Dry, indoor Radio Frequency Interference (RFI) Immunity: No alarm on critical frequencies in the range from 26 MHz to 950 MHz at field strengths less than 30 V/m. Temperature (Operating): +32°F to +120°F (0°C to +49°C) Mechanical Properties Dimensions (H x W x D):4.75 in. x 3.75 in. x 3.25 in. (12 cm x 9.5 cm x 8.2 cm) Material:Die cast zinc alloy and steel Power Requirements Current Draw (Mux Bus Average): Alarm: 0.55 mA Standby: 0.55 mA Voltage (Operating):12 VDC nominal (provided by the MUX bus) Ordering information FMM‑7045 Single‑Action Manual Station The single‑action manual station is UL listed and meets Americans with Disabilities Act (ADA) requirements. Its address on the polling circuit is easily set with rotary switches. The pull handle locks in the activated position and is reset by opening the unit with a key and then relocking it. Order number FMM-7045 FMM‑7045‑D Double‑Action Manual Station The double‑action manual station is UL listed and meets Americans with Disabilities Act (ADA) requirements. Its address on the polling circuit is easily set with rotary switches. The pull handle locks in the activated position and is reset by opening the unit with a key and then relocking it. Order number FMM-7045-D Accessories D102 Replacement Key Replacement key (#1358) for LOCK‑1358 and the D101 lock. Order number D102 2 | FMM‑7045 Multiplex Addressable Manual Stations FMM‑100GR Scored Acrylic Break Rods Scored acrylic rods (12 per package) Order number FMM-100GR 3 | FMM‑7045 Multiplex Addressable Manual Stations Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2014 | Data subject to change without notice 2708533771 | en, V2, 11. Aug 2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7150-1615:0224 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FMM-100, followed by DAT (Dual Action with terminal strip) or SAT (Single Action with terminal strip) may be followed by K or K-NYC (key lock with single contact) or 2CK (Key lock with dual contacts) noncoded manual pull stations. FMM-100BB indoor back box, Suitable for outdoor use when installed with Model FMM-100WPBB back box. *FMM-100DBB-R surface mount deep back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:30 VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Only Models FMM-100DATK, -100SATK, -100SAT2CK manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF:7150-1408:0107 *Revised 09-01-2016 dc July 01, 2018Date Issued:Listing Expires June 30, 2019 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Fire Alarm Systems | D263 Photoelectric Smoke and Smoke and Heat Detectors D263 Photoelectric Smoke and Smoke and Heat Detectors www.boschsecurity.com u 12 V or 24 V input u Designed for commercial or residential use u Two-wire application u Light-emitting diodes (LEDs) indicate the status of the chamber, power, and alarm u Removable terminal block to simplify wiring connections The D263 family includes the following detector models: Model Description D263 Two-wire D263TH Two-wire with 135°F (57°C) heat sensor D263THS*Two-wire with 135°F (57°C) heat sensor and sounder * Sounders produce 85 dB at 10 ft (3 m). Each of these detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. System overview These detector models use an infrared (IR) LED light source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to deter insects and to reduce dust accumulation and nuisance alarms. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. Use a D132B Reversing Relay Module to activate the sounder (85 dB at 10 ft [3 m]). When using a D132B, the LED does not latch on alarm. Functions Chamber Calibration Tests Check the sensitivity and calibration of any of these detectors using a visual check, a magnet test, or a voltage measurement test. Visual check: When the detector’s calibration is within the factory- listed range, the red alarm LED flashes once every 3.5 sec. If the detector’s calibration is out of range for more than 24 h, the red alarm LED flashes once a second. Magnet test: Hold a magnet horizontally against the detector for about 10 sec and observe the LED. • If the detector is within the factory-listed calibration range, it goes into alarm and the Alarm LED latches on. • If the detector is too sensitive, the LED rapidly flashes six times (once every half second) and the detector signals an alarm. • If the detector is not sensitive enough, the LED slowly flashes four times, once every 2 seconds, and the detector signals an alarm. • If the detector does not operate, it does not signal an alarm. Voltage measurement test: Use a D1005 Test Cable and a digital voltmeter to measure the voltage and compare the results with the factory-listed sensitivity range. Certifications and approvals Region Certification USA UL UROX: Smoke - Automatic Fire Detectors(UL268 and A), UROX7: Smoke - Auto-matic Fire Detectors Certified for Cana-da (cULus), CSFM see our website NYC-MEA 274-93-E, Vol. VII MSFM Hong Kong HKFSD D263\TH\THS Installation/configuration notes Use smoke detectors for detection circuits that protect people. Use heat detectors for circuits that protect property. Compatible Products The following products are compatible with the D263 Series detectors: Category Product ID Product Description Control Panels Bosch Security Systems makes no claim written, oral, or implied that the D263 Series detectors work with any two-wire control panels except those specified in the Control Panel Compatibility chart in Technical Service Note (P/N: 31866). Modules D132B Reversing relay module Mounting The detector has a mounting plate that attaches on a standard four-inch back box. For commercial and industrial installations in accordance with NFPA 72, space each detector 30 ft (9.2 m) apart. Wiring The terminal block accepts up to 12 AWG (ISO 4 mm2) wire. You can remove the terminal block from the detector for easier wiring. The terminal block snaps in and out of the detector. Parts included Quantity Component 1 Detector 1 Lit pack – Installation Manual, Technical Service Note on installation Technical specifications Environmental Considerations Radio Frequency Interference (RFI) Immunity: No alarm on critical frequencies in the range of 26 MHz to 950 MHz. Relative Humidity:Up to 93%, non-condensing Temperature (operating):+32°F to +120°F (0°C to +40°C) Mechanical Properties Dimensions (Diameter x H):5 in. x 2 in. (12.7 cm x 5.1 cm) Material:High impact, fire retardant ABS plastic Relay Contacts Auxiliary Form C: 1 A, 120 VAC/30 VDC at 1 A, 30 W maximum Power Requirements Current Draw (alarm):Determined by control panel Current Draw (standby):0.080 mA at 12 V, 0.1 mA maximum Current Draw (start-up):0.12 mA Current Draw (trouble):0.1 mA maximum Power-up Time:22 sec maximum RMS Ripple (maximum):25% of DC input Voltage (stand-by):8.5 VDC to 33 VDC Ordering information D263 Two‑Wire Smoke Detector Two‑wire photoelectric smoke detector. Order number D263 D263TH Two‑Wire Smoke/Heat Detector Two‑wire photoelectric smoke detector with a 135°F (57°C) heat sensor. Order number D263TH 2 | D263 Photoelectric Smoke and Smoke and Heat Detectors D263THS Two‑Wire Smoke/Heat Detector with Sounder Ttwo‑wire photoelectric smoke detector with a 135°F (57°C) heat sensor and a sounder. Order number D263THS Accessories D1005 Test Cable Connects a digital voltmeter to the detector's calibration pin for verifying that the detector is within its calibration range Order number D1005 DT‑2 Detector Removal Tool Use the DT‑2 to remove, replace, or test the detector head Order number DT-2 TP280 Trim Plate For retrofit and remodeling purposes; 16.2 cm (6 in.) diameter Order number TP280 3 | D263 Photoelectric Smoke and Smoke and Heat Detectors Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 203 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2015 | Data subject to change without notice 2700390283 | en, V9, 14. Aug 2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7272-1615:0134 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Models D285, D285DH, D285TH, D263, D263TH, D273, D273TH, D273THS, D263THC, D263THS, D273THR, D273THC, D273IS, D273THCS, D273THSR, D273THE, D273ES and D273THES smoke detectors. Model D285TH, D263TH and D273THxx employ an integral 1350 fixed temperature heat detector. This heat sensor is intended for use only as a supplemental device to assist the smoke detector. *Model D285 series are separable detector heads which operate with separable base Models D287, D288, D292, D293A, D293E and D293S. *Models D263 and D273 series detectors are nonseparable detector heads with terminal blocks and do not operate with separable bases. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:8.5 - 33.0 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control unit. Models D285 and D285TH are intended for use with separately listed bases. Model D285DH is intended for use with separately listed Duct Smoke Detector Housing Model D341 or D342 (CSFM Listing No. 3240-1615:181) or Model D340 (CSFM Listing No. 3240-1615:184). Refer to listee’s Installation Instruction Manual for details. NOTE: Formerly 7272-0801:162 *Rev. 05-29-2007 jw July 01, 2018Date Issued:Listing Expires June 30, 2019 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Fire Alarm Systems | D7052 Multiplex Dual‑input Module D7052 Multiplex Dual‑input Module www.boschsecurity.com u Use with D7024, DS9400M, or FPD‑7024 Addressable FACPs u Fits into a standard double‑gang or four‑inch square back box u Easy addressing using rotary switches u Low current draw u UL Listed The D7052 Multiplex Dual‑input Module connects normally‑open (NO) contacts to the multiplex bus of a D7024, DS9400M, or FPD‑7024 Addressable Fire Alarm Control Panel (FACP). Use the module for two Class B (Style B) supervised inputs or one Class A (Style D) input. All operating power for the input module is drawn from the FACP. Notice The D7024 and DS9400M are not listed under UL864, 9th edition. Rotary switches allow convenient address setting. An on‑board status LED on the module indicates normal, alarm, and trouble conditions and is visible on the module or on an attractive, low‑profile faceplate. Certifications and approvals Region Certification USA UL UOJZ: Control Units, System (ANSI/UL864) and UOXX: Control Unit Accesso-ries, System (ANSI/UL 864) FM D7052 Region Certification CSFM see our website FDNY-CoA #6173 Installation/configuration notes Compatible Products The following products are compatible with the D7052 Multiplex Dual‑input Module: Category Product ID Product Description Control Panels D7024 Addressable FACP D7024‑EXP Addressable FACP for export DS9400M Addressable FACP FPD‑7024 Addressable FACP Modules D7039 Multiplex expansion module Mounting Mount the module on a double‑gang or four‑inch square back box. Wiring Make connections to the terminals on the rear of the module. All terminals can accommodate up to 12 AWG (ISO 4 mm2) wire; however, follow wiring guidelines specified by the National Electrical Code (NFPA‑70). All wiring is power limited and supervised. Notice Do not use shielded wire. Notice Supervise Class B input loops with the supplied EOL resistors. A Class A loop does not require an EOL resistor. Parts included Quant.Component 1 D7052 module 2 2.21 kΩ end‑of‑line (EOL) resistors (P/N: 25899) 1 Literature pack 1 Hardware pack Technical specifications Circuit Designation MUX Bus:Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input:Supervised Class A (Style D) IDC or Class B (Style B) IDC Environmental Considerations Environment:Indoor, dry Relative Humidity:Up to 93% non‑condensing Temperature (operating):+32°F to +120°F (0°C to +49°C) Inputs Type:Two normally‑open (NO) Class B (Style B) contact inputs or one Class A (Style D) contact input supervised by a 2.21 kΩ EOL resistor (P/N: 25899) Mechanical Properties Color:White Dimensions:4.3125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep Material:ABS plastic Weight:3.9 oz (110 g) Power Requirements (supplied from FACP's MUXbus) Current:0.55 mA Voltage (minimum):8 V peak (12 VDC nominal) Ordering information D7052 Multiplex Dual‑input Module The D7052 connects normally‑open (NO) contacts to the multiplex bus of a D7024, DS9400M, or FPD‑7024 FACP. The D7044's input power is drawn from the FACP for use in two Class B (Style B) supervised inputs or one Class A (Style D) input. Rotary switches allow convenient address setting. Order number D7052 2 | D7052 Multiplex Dual‑input Module 3 | D7052 Multiplex Dual‑input Module Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2014 | Data subject to change without notice 2692044555 | en, V4, 22. Jul 2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7165-1615:0227 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterflow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033, FMR-7036; Keypad D7035, D7035B; Expanded Relay Module D185; Reverse Polarity Module D7039, *FPE-7039; MUX Expander D7042, D7042B, D7044, D7044M, D7052, D7053; Mulitplez Expander Module D7048, D7048B; Octal Driver Module B440, B441, B443; Cellular Modules B450; Interface Module *FLM-7024-ISO; MUX Bus Isolator Module RATING:120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee’s printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee’s name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee’s Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Revsion 02-15-17 gt July 19, 2018Date Issued:Listing Expires June 30, 2019 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253  Phone (760)777-7000 Direct (760)777-7074 8/28/2018 Jeff Rogers HCI Systems 4585 Murphy Canyon Rd. San Diego CA, 92123 Re: Fire Alarm System Plan Review – Washington Street Apartments – Phase 2 FA2018-0007 42-800 Washington St. La Quinta CA The alarm plans you submitted for the above referenced project have been reviewed by the Riverside County Fire Department and are approved with the following conditions: 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. All fire alarm notification and initiating appliances shall be tested in accordance with NFPA 72. c) 5-Minute Ring-out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 5. A zone map indicating location of all initiating devices shall be installed at an approved location. 6. All equipment keys shall be provided for placement in building’s KNOX box systems for Fire Department access. 7. All j-boxes and electric boxes serving fire alarm system shall be red in color or labeled. 8. Compartment/room containing fire alarm equipment that is capable of system operation shall be labeled "FACP" on exterior side. 9. All electrical breaker circuit switches controlling fire alarm power source shall be locked in the ON position for the life of the system by an approved lock-out assembly. Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253  Phone (760)777-7000 Direct (760)777-7074 10. All signals witnesses at function testing shall be verified before final approval is granted. The Fire Department approved plans, job card and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)863-8886. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez Fire Safety Specialist