Loading...
FSS2020-0107ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (800)915-3473 jamieb@fireinc.net BILL TO FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (800)915-3473 jamieb@fireinc.net CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (800)915-3473 jamieb@fireinc.net OWNER BARBARA MURAKAMI 78995 DRY CREEK LA QUINTA CA 92253 (800)915-3473 jamieb@fireinc.net CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST ARMANDO MAGALLON 8/17/2020 PENDING BRES2020-0128 NEEDS TO BE ISSUED BEFORE ISSUANCE OF FIRE SPRINKLER CONDITIONS Description: MURAKAMI / BRES2020-0128 / FIRE SPRINKLER Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: APPROVED-CONDITIONS Applied: 8/10/2020 AMA Parcel No: 776010018 Site Address: 78995 DRY CREEK RD LA QUINTA,CA 92253 Approved: 8/17/2020 KHET Subdivision: Block: Lot: Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $0.00 Occupancy Type: Construction Type: Expired: 2/13/2021 ECON No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, February 22, 2023 3:47:07 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0107 INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 8/6/2020 8/20/2020 8/17/2020 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 8/10/2020 8/11/2020 8/13/2020 COMPLETE ALL OF THE ATTACHMENTS HAVE BEEN MOVED FROM FCMP2020-0015. FCMP2020-0015 HAS BEEN VOIDED AND THIS PERMIT CREATED. PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 8/17/20 WEB6017 CREDIT FIRE SPRINKLER SYSTEMS INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $11.00 $11.00 8/6/20 R61901 006548 CREDIT FIRE SPRINKLER SYSTEMS INC AMA FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $231.00 $231.00 8/17/20 WEB6017 CREDIT FIRE SPRINKLER SYSTEMS INC ECON Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 8/6/20 R61901 006548 CREDIT FIRE SPRINKLER SYSTEMS INC AMA Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 8/6/20 R61901 006548 CREDIT FIRE SPRINKLER SYSTEMS INC AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Wednesday, February 22, 2023 3:47:07 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0107 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/13/2020 ARMANDO MAGALLON APPLICATION Scull Applicaiton 1.pdf 1 DOC 8/13/2020 ARMANDO MAGALLON 1ST SUBMITTAL - CALCS 31991-00 CALC.pdf 1 DOC 8/13/2020 ARMANDO MAGALLON 1ST SUBMITTAL - FIRE FLOW TEST 31991-00 FIRE FLOW TEST.pdf 1 DOC 8/13/2020 ARMANDO MAGALLON 1ST SUBMITTAL - SPRINKLER PLAN 31991-00 SPRINKLER PLAN.pdf 1 DOC 8/17/2020 KOHL HETRICK FSS2020-0107 - COA and JOB CARD.pdf FSS2020-0107 - COA and JOB CARD.pdf 1 DOC 8/17/2020 KOHL HETRICK FSS2020-0107 - APPROVED PLANS.pdf FSS2020-0107 - APPROVED PLANS.pdf 1 DOC 8/27/2020 KOHL HETRICK FSS2020-0107 - COA and JOB CARD.pdf FSS2020-0107 - COA & JOB CARD.pdf 1 DOC 8/27/2020 KOHL HETRICK FSS2020-0107 - APPROVED PLANS.pdf FSS2020-0107 - APPROVED PLANS.pdf 1 BOND INFORMATION Printed: Wednesday, February 22, 2023 3:47:07 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0107 E E EE E E E E E E E L L E E V V E E E E F F F EE E E E CO E E E E E E E E CO E E E E E E E E E E E E E E E H H F V E F V E H CW E E E E E E E E E E E E E E E E H P P P E E P E E LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, ENGINEERING AND INSTALLATION 1/4" = 1' IF SHEET IS LESS THAN SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLY CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems.VIKINGVIKING4.94.9200°175°16'x16'16'x16'SPACINGTEMP.K-FAC.SYMBOLMODELMANUF.SIN #VK494VK468FREEDOMPENDENT7/16"7/16"ORIFICEFREEDOMCONC. PEND.255QUANTITY-TOTAL SPRINKLERS IN THIS SHEET:30--------CUSTOM FIRE SPRINKLER PLAN SHEET FP2 OF FP3 DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 13D, 2016 ED. NOTES: 1.ALL HEAD SPACING TO BE 16'x16', UNLESS OTHERWISE NOTED. 2.ALL PIPES TO BE ¾" CPVC, UNLESS OTHERWISE NOTED. 3.PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA 13-9.3.4. 4.HANGERS SHOWN FOR REFERENCE PURPOSES ONLY. HANGER SPACING TO BE PER TABLES ON THIS SHEET. 5.ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE PROVIDED WITH MIN. 6" INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE (2016 NFPA 13D 7.7). 6.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55sqft. AND LESS. (SECTION 8.3.2.) 7.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING REQUIREMENTS: (1) THE AREA OF THE SPACE DOES NOT EXCEED 24sqft. (2) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. 8. 8.2.5.1.2 THE DISTANCE SHALL BE MEASURED FROM THE CENTER OF THE SPRINKLER TO THE CENTER OF THE OBSTRUCTION. 9. 8.2.5.6 SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS THE CUMULATIVE DRY AREA DO NOT EXCEED 15sqft (1.4 sqm) PER SPRINKLER. TOTAL LIVING AREA - GARAGE AREA- 2,616 SQ. FT. 444 SQ. FT. SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - CARBON STEEL. FINISH - Mil. Galvanized. LISTING/APPROVAL - 203-EX 4231, EX 2551 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC PIPE - #905 screw - no pre-drill. 3/4" - 3" Steel and Copper pipe - #14 x 1 1/2" SMS or 1/4"x1 1/2" lag bolt - no pre-drill. in STEEL: min. 18 GA. 3/4" - 3" CPVC, Copper and Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap StabilizeHanger Restraint 2.126 2.312 3.170 3.400 4.320 5.3203 2 1/2 1 1/2 1 1/4 1 3/4 510 SIZE FAST. DIM. AFCON 510 HANGER (STEEL - COPPER - C.P.V.C.) NOT TO SCALE Nominal Pipe Size (in.) ¾"1"1¼"1½"2"2½"3"3½"4"5"6"8" N/A 12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 12'-0"N/A 15'-0" 12'-0"12'-0"12'-0"12'-0"12'-0"N/A N/A N/A N/A N/A 8'-0"8'-0"10'-0"10'-0"12'-0"12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 5'-6"6'-0"6'-6"7'-0"8'-0"9'-0"10'-0"N/A N/A N/A N/A N/A N/A 3'-9"4'-7"5'-0"5'-11"N/A N/A N/A N/A N/A N/A N/A 2'-11"3'-4"3'-11"4'-5"5'-5"N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'-0"N/A N/A 15'-0"N/A 15'-0"15'-0" Steel pipe except threaded lightwall Threaded lightwall steel pipe Copper tube CPVC Polybutylene (IPS) Polybutylene (CTS) Ductile iron pipe 1.50 #905 #906 AFCON 514 HANGER (STEEL - COPPER - C.P.V.C.) NOT TO SCALE Restraint Restraint Nominal Pipe Size (in.) ¾"1"1¼"1½"2"2½"3"3½"4"5"6"8" N/A 12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 12'-0"N/A 15'-0" 12'-0"12'-0"12'-0"12'-0"12'-0"N/A N/A N/A N/A N/A 8'-0"8'-0"10'-0"10'-0"12'-0"12'-0"12'-0"15'-0"15'-0"15'-0"15'-0"15'-0" 5'-6"6'-0"6'-6"7'-0"8'-0"9'-0"10'-0"N/A N/A N/A N/A N/A N/A 3'-9"4'-7"5'-0"5'-11"N/A N/A N/A N/A N/A N/A N/A 2'-11"3'-4"3'-11"4'-5"5'-5"N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'-0"N/A N/A 15'-0"N/A 15'-0"15'-0" Steel pipe except threaded lightwall Threaded lightwall steel pipe Copper tube CPVC Polybutylene (IPS) Polybutylene (CTS) Ductile iron pipe SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Glavanized. LISTING/APPROVAL - INSTALLATION - Per these instructions PATENT - No. 6,648,278. 203-EX 4231, EX 2551 Stabilize vertical piping. Install on horizontal or vertical mounting surface. FUNCTION - Support horizontal piping: CPVC, Copper or Steel. WOOD - CPVC pipe - #905 screw- no pre-drill. Provides listed vertical/horizontal restraint and prevents Thru 5/8" gypsum board - 1/4"x 2" lag screw. upward movement of pipe from pendent sprinkler discharge. When #905 threads are exposed in wood, install #906 backing nut. including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Snap over pipe then squeeze strap back allowing pipe to slide freely. STEEL - min. 18 GA. - CPVC, Copper and Stell pipe - 1/4" or #14 Tek Screw. FASTENERS - UL Listed per NFPA 13 CONCRETE: Required minimum load each fasterner = 5(wt)+250lbs. Copper and Steel pipe - #14 SMS or 1/4 "x1 1/2" lag screw - no pre-drill. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * Common center-line for 3/4" and 1". * Offset edge eliminates abrasion. * AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. AFCON #906 backing nut sold serparately. 3.00 Stabilize Hanger/Restrainer NO.DATEREVISION123452 8 0 10 3 0 6 0 2 0 5 0 3 0 6 0 3 0 6 0 3 0 6 0 2 0 4 0 CO V E R E D P A T I O 10'- 0 " C L G . KIT C H E N 10'- 0 " C L G . GR E A T R O O M 10'- 0 " C L G . PA N T R Y / W I N E 10'- 0 " C L G . BA T H 3 9'-0 " C L G . BE D R O O M 3 9'-0 " C L G . W.I. C . 9'-0 " C L G . LIN E N BE D R O O M 2 9'-0 " C L G . MEDIA 9'-0" CLG. GALLERY 10'-0" CLG. BATH 2 9'-0" CLG. W.I.C. 9'-0" CLG. 53 SQFT. ENTRY 10'-0" CLG. COVERED PORCH 14'-0" CLG. LAUNCH 9'-0" CLG. LAUNDRY 9'-0" CLG. ATTIC ACCESS 9'-0" CLG. LINEN MASTER BEDROOM 10'-0" CLG. 28 SQFT. MASTER BATH 10'-0" CLG. W.I.C. 10'-0" CLG. GARAGE 10'-0" CLG. LINEN HE A T Z O N E SCALE: 1/4" = 1'-0" FIRE SPRINKLER PLAN 9'-0" CLG. 20 SQ. FT. HE A T Z O N E RISER LOCATIONDN ¾" x 1 '-0" 10 CALC AREA 1 25 S Q . F T . 1'10'-2"1'4'-1"6'-4"10'-1"6'-11"9'-11"3'-10"6'-1"9'-3"3'-7"4'-5"2'-11" 4'-2" 3'-4" 5'-2" 1'-2" 1'10'-1"1'3'7'-5"2'-2"2'-6"8'-8"4'-1"1'-4"2'6'-5"6'-3"1'1'11' 14' 7'-4 " 1'-1 "9'-4"6'-6"1'-9"2'-1 "3'-2"1'1'1'5'-7 " 5'-5 " 6'-1 1 " 7'-2 " 3'-2 " 3' 5'-2 "15'1'5'-6"2'-11"7" 2'-1 "6'-9"2'-5"1'1'2'-6"4'-1"5'-7"1' 1'8'-11"2'-2"1'-4"2'-2"11'-2"10'-1"6'-2"5'5'-5"7' 5'-11"9'-11"8'2'-3" 8'9'-3"7'-2"7'-2"5'-10"5'5'-10" 5'-8"3'-10"5'-2"2'-5"7'-8"7'-4"13'-6"6'-7"2'-9"9'6'-6"4'-1"3'-10"5'-4"9'6'-8"6'-1 1 "2'-9"4'-6"5'-5 "3'-5"14'16'11' 7'-6 "3'-2"3'DN ¾" x 1 '-0"DN ¾" x 1 '-0"DN ¾" x 1 '-0"DN ¾" x 1 '-0"DN ¾" x 1'-0"(2) 90° ELBOWS (2) 90° ELBOWS20'x 2 0 ' S P A C I N G 20'x 2 0 ' S P A C I N G LIN E N 9'-0 " C L G .4'-8"11 17 16 14 15 12 13 18 CALC AREA 2 DRAWN BY: 31991 7/30/20 JOB NO: DATE: C.P.BARBARA MURAKAMISCULLBY:LA QUINTA, CA.CUSTOM78995 DRY CREEK ROAD---------9'-0" CLG. 4:12 CUSTOM SECTIONS LICENSE NO. 684600 705 E. HARRISON ST., SUITE 200 CORONA, CA 92879 PH - 800-915-3473 FAX - 951-272-2535 CUSTOM, TRACT, MULTI-FAMILY AND COMMERCIAL DESIGN, ENGINEERING AND INSTALLATION 1/4" = 1' IF SHEET IS LESS THAN SHEET FP3 OF FP3 SIZE - 24" X 36" SHEET ID 24" X 36" IT IS A REDUCED SCALE PRINT SCALE REDUCE ACCORDINGLYNO.DATEREVISION12345CLASSIFICATION C-16 LICENSE NO. 684600FIREPROTECTIONCO N T R ACTORFST A TE OF C A L IF O RNIAThe recipient of these plans hereby acknowledges that all plans, details, specifications or methods of installation contained in this set of plans is the sole property of Fire Sprinkler Systems, Inc. and that any use of this set of plans is prohibited and is a violation of copyright laws without first receiving permission from Fire Sprinkler Systems.SECTIONS FOR REFERENCE ONLYWDW HDR 8'-0"9'-1"F.F. T.P. F.F. T.P. F.F. T.P.10'-1"F.F. T.P. WDW HDR 8'-0"10'-1"10'-1"F.F. T.P. F.F. T.P.9'-1"10'-1"F.F. T.P.14'-1"F.F. T.P.10'-1"10'-1"F.F. T.P.10'-1"F.F. T.P.10'-1"10'-1"SCALE: 1/4" = 1'-0" SECTION A SCALE: 1/4" = 1'-0" SECTION B SCALE: 1/4" = 1'-0" SECTION C GREAT ROOM STO.GALLERY LAUNDRY LAUNCH 9'-1"10'-1"9'-1"W.I.C.GARAGE COVERED PATIO GALLERY PORCH MASTER BEDROOM MASTER BATH MASTER BATH GARAGE DRAWN BY: 31991 7/30/20 JOB NO: DATE: C.P.BARBARA MURAKAMISCULLBY:LA QUINTA, CA.CUSTOM78995 DRY CREEK ROAD DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA, RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR SCULL LA QUINTA, CA. 78995 DRY CREEK ROAD *10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 1 Date: 7/30/2020 File No: 31991 Data File Name: 31991-00.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK494 Conc.Pend.(16x16) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm-Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 87.2 psi Resid: 82.1 psi Flow:1550.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 5 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 7.6 17 18.0 87.2 30.7 2 13.0 7.6 17 31.2 87.2 52.9 REVIEWING AUTHORITY LA QUINTA F.D. DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD * * P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) ====================================*=====================*===================== 1 1 30.00 BG ---- -2.0 SRCE ---- 18.0 3.30 30.7 ---- 31.1 9.09 52.9 150 2 0.995 6.0 ---- -2.0 ---- ---- 0.09 0.00 27.4 ---- 0.25 0.00 43.8 2 2 1.00 -4.0 -2.0 ---- ---- 18.0 0.09 27.4 ---- 31.2 0.25 43.8 150 3 0.995 0.0 ---- -2.0 ---- ---- 0.09 0.00 23.3 ---- 0.25 0.00 39.5 3 3 70.00 3L ---- -2.0 ---- ---- 18.0 0.91 23.3 ---- 31.2 2.50 39.5 150 4 1.590 27.0 ---- -2.0 ---- ---- 0.01 0.00 22.4 ---- 0.03 0.00 37.0 4 4 4.00 L ---- -2.0 ---- ---- 18.0 0.10 22.4 ---- 31.2 0.27 37.0 150 5 1.505 4.0 ---- 2.0 -5 5 0.01 1.73 20.6 5 0.03 1.73 35.0 5 5 2.00 R ---- 2.0 -5 5 13.0 0.09 20.6 5 26.2 0.34 35.0 150 6 1.101 1.0 ---- 4.0 ---- ---- 0.03 0.87 19.6 ---- 0.11 0.87 33.8 6 6 1.00 -3.0 4.0 ---- ---- 13.0 0.03 19.6 ---- 26.2 0.11 33.8 150 7 1.101 0.0 ---- 4.0 ---- ---- 0.03 0.00 16.6 ---- 0.11 0.00 30.7 7 7 7.00 2R ---- 4.0 ---- ---- 13.0 0.28 16.6 ---- 26.2 1.01 30.7 150 10 1.101 2.0 ---- 11.0 ---- ---- 0.03 3.03 13.3 ---- 0.11 3.03 26.7 8 10 11.50 2LR ---- 11.0 ---- ---- 13.0 1.94 13.3 ---- 26.2 7.05 26.7 150 11 0.874 9.0 ---- 11.0 ---- ---- 0.09 0.00 11.4 ---- 0.34 0.00 19.6 9 11 69.00 3L2B9R ---- 11.0 ---- ---- 6.3 2.36 11.4 ---- 13.0 9.08 19.6 150 12 0.874 27.0 ---- 11.0 ---- ---- 0.02 0.00 9.0 ---- 0.09 0.00 10.5 10 12 10.50 2LB ---- 11.0 ---- ---- 0.0 0.00 9.0 ---- 0.0 0.00 10.5 150 13 0.874 11.0 ---- 10.0 ---- ---- 0.00 0.43 9.4 ---- 0.00 0.43 11.0 11 12 22.00 B2R ---- 11.0 ---- ---- 6.3 0.66 9.0 ---- 13.0 2.55 10.5 150 14 0.874 5.0 ---- 11.0 ---- ---- 0.02 0.00 8.3 ---- 0.09 0.00 8.0 12 14 1.00 R ---- 11.0 ---- ---- 0.0 0.00 8.3 ---- 13.2 0.19 8.0 150 15 0.874 1.0 ---- 11.0 4.71 ---- 0.00 0.00 8.3 13.2 0.10 0.00 7.8 13 14 11.00 B ---- 11.0 ---- ---- 6.3 0.34 8.3 ---- -0.1 0.00 8.0 150 16 0.874 3.0 ---- 11.0 ---- ---- 0.02 0.00 8.0 ---- 0.00 0.00 8.0 14 16 1.00 B ---- 11.0 ---- ---- 13.0 0.38 8.0 ---- 13.0 0.38 8.0 150 17 0.874 3.0 ---- 11.0 4.71 13.0 0.09 0.00 7.6 13.0 0.09 0.00 7.6 15 16 48.00 E2L6R ---- 11.0 ---- ---- -6.7 1.75 8.0 ---- -13.1 6.06 8.0 150 18 0.874 15.0 ---- 11.0 ---- ---- -0.03 0.00 9.8 ---- -0.10 0.00 14.1 16 18 47.00 2B5R ---- 11.0 ---- ---- -6.7 1.61 9.8 ---- -13.1 5.58 14.1 150 11 0.874 11.0 ---- 11.0 ---- ---- -0.03 0.00 11.4 ---- -0.10 0.00 19.6 DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 3 Node Notes Pipe Notes Legend: P - Pipe # LEN - Pipe Length DIA - Pipe Diameter FIT. - Pipe Fittings EQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss Device PUMP - Pump Pressure EL - Node Elevation SP - K-Factor DISCH - Discharge in gpm FLOW - Flow Rate FL/FT - Friction Loss per Foot PF - Pressure Loss due to Friction PE - Pressure Loss due to Elevation PT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVlv, X= X, Y= Y, Z= The maximum velocity of water flow occurs in pipe 2 at 7.43 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 13.99 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.505 2.00 4.00 9.00 3.00 3.00 10.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.590 2.00 9.00 8.00 1.00 1.00 14.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.01 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.06 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 4 of 52.9 psi and a 7 minute flow of 218 gal. and a 10 minute flow of 311.5 gallons. The minimum pressure at any node is 7.6 psi at node 17. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 5 WATER SUPPLY CURVE 0 0.0 4 9.0 8 18.0 12 27.0 16 36.0 20 45.0 24 54.0 28 63.0 32 72.0 36 81.0 40 90.0 P R E S S U R E ( P S I ) Static = 87.2 psi, Residual = 82.1 psi @ 1550 gpm (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply 87.2 psi @ 18.0 gpm A B = Required Water Supply 30.7 psi @ 18.0 gpm B C = Available Water Supply 87.2 psi @ 31.2 gpm C D = Required Water Supply 52.9 psi @ 31.2 gpm D FLOW (GPM) DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 6 DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 1 FIRE SPRINKLER SYSTEMS 705 E. HARRISON, SUITE 200 CORONA, RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR SCULL LA QUINTA, CA. 78995 DRY CREEK ROAD *10% TAKEN OFF WATER SUPPLY FOR SAFETY MARGIN CALC AREA 2 Date: 7/30/2020 File No: 31991 Data File Name: 31991-00.rdf SPRINKLER SPACING 400.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 20.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 10.0 ft. SPRINKLER SPECIFICATIONS Mfr: Viking Descr: VK494 Conc.Pend.(20x20) K=4.90 Calculated K Factor for Arm-Overs & Drops: 1.0 ft. x 0.874 in. Drop: K=4.71 (Incl. 1 Tee) 0.0 ft. x 0.874 in. Arm-Over: K=4.67 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 87.2 psi Resid: 82.1 psi Flow:1550.0 gpm Public Main Size: 8 in Domestic Demand: 5.0 gpm at node number 5 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 20.0 18.0 13 25.0 87.2 55.1 1 20.0 18.0 13 25.0 87.2 55.1 REVIEWING AUTHORITY LA QUINTA F.D. DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 2 RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 1 sprinklers flowing FIXD * * P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT HWC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI)*(GPM) FL/FT PE (PSI) ====================================*=====================*===================== 1 1 30.00 BG ---- -2.0 SRCE ---- 25.0 6.06 55.1 ---- 25.0 6.06 55.1 150 2 0.995 6.0 ---- -2.0 ---- ---- 0.17 0.00 49.0 ---- 0.17 0.00 49.0 2 2 1.00 -4.0 -2.0 ---- ---- 25.0 0.17 49.0 ---- 25.0 0.17 49.0 150 3 0.995 0.0 ---- -2.0 ---- ---- 0.17 0.00 44.8 ---- 0.17 0.00 44.8 3 3 70.00 3L ---- -2.0 ---- ---- 25.0 1.66 44.8 ---- 25.0 1.66 44.8 150 4 1.590 27.0 ---- -2.0 ---- ---- 0.02 0.00 43.2 ---- 0.02 0.00 43.2 4 4 4.00 L ---- -2.0 ---- ---- 25.0 0.18 43.2 ---- 25.0 0.18 43.2 150 5 1.505 4.0 ---- 2.0 -5 5 0.02 1.73 41.3 5 0.02 1.73 41.3 5 5 2.00 R ---- 2.0 -5 5 20.0 0.20 41.3 5 20.0 0.20 41.3 150 6 1.101 1.0 ---- 4.0 ---- ---- 0.07 0.87 40.2 ---- 0.07 0.87 40.2 6 6 1.00 -3.0 4.0 ---- ---- 20.0 0.07 40.2 ---- 20.0 0.07 40.2 150 7 1.101 0.0 ---- 4.0 ---- ---- 0.07 0.00 37.1 ---- 0.07 0.00 37.1 7 7 7.00 2R ---- 4.0 ---- ---- 20.0 0.61 37.1 ---- 20.0 0.61 37.1 150 10 1.101 2.0 ---- 11.0 ---- ---- 0.07 3.03 33.5 ---- 0.07 3.03 33.5 8 10 11.50 2LR ---- 11.0 ---- ---- 20.0 4.29 33.5 ---- 20.0 4.29 33.5 150 11 0.874 9.0 ---- 11.0 ---- ---- 0.21 0.00 29.2 ---- 0.21 0.00 29.2 9 11 69.00 3L2B9R ---- 11.0 ---- ---- 11.4 7.11 29.2 ---- 11.4 7.11 29.2 150 12 0.874 27.0 ---- 11.0 ---- ---- 0.07 0.00 22.1 ---- 0.07 0.00 22.1 10 12 10.50 2LB ---- 11.0 ---- ---- 20.0 4.50 22.1 ---- 20.0 4.50 22.1 150 13 0.874 11.0 ---- 10.0 4.71 20.0 0.21 0.43 18.0 20.0 0.21 0.43 18.0 11 12 22.00 B2R ---- 11.0 ---- ---- -8.6 1.19 22.1 ---- -8.6 1.19 22.1 150 14 0.874 5.0 ---- 11.0 ---- ---- -0.04 0.00 23.3 ---- -0.04 0.00 23.3 12 14 1.00 R ---- 11.0 ---- ---- 0.0 0.00 23.3 ---- 0.0 0.00 23.3 150 15 0.874 1.0 ---- 11.0 ---- ---- 0.00 0.00 23.3 ---- 0.00 0.00 23.3 13 14 11.00 B ---- 11.0 ---- ---- -8.6 0.61 23.3 ---- -8.6 0.61 23.3 150 16 0.874 3.0 ---- 11.0 ---- ---- -0.04 0.00 23.9 ---- -0.04 0.00 23.9 14 16 1.00 B ---- 11.0 ---- ---- 0.0 0.00 23.9 ---- 0.0 0.00 23.9 150 17 0.874 3.0 ---- 11.0 ---- ---- 0.00 0.00 23.9 ---- 0.00 0.00 23.9 15 16 48.00 E2L6R ---- 11.0 ---- ---- -8.6 2.77 23.9 ---- -8.6 2.77 23.9 150 18 0.874 15.0 ---- 11.0 ---- ---- -0.04 0.00 26.6 ---- -0.04 0.00 26.6 16 18 47.00 2B5R ---- 11.0 ---- ---- -8.6 2.55 26.6 ---- -8.6 2.55 26.6 150 11 0.874 11.0 ---- 11.0 ---- ---- -0.04 0.00 29.2 ---- -0.04 0.00 29.2 DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 3 Node Notes Pipe Notes Legend: P - Pipe # LEN - Pipe Length DIA - Pipe Diameter FIT. - Pipe Fittings EQV. LN - Pipe Equivalent Length FIXD LOSS - Fixed Loss Device PUMP - Pump Pressure EL - Node Elevation SP - K-Factor DISCH - Discharge in gpm FLOW - Flow Rate FL/FT - Friction Loss per Foot PF - Pressure Loss due to Friction PE - Pressure Loss due to Elevation PT - Total Pressure at Node Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVlv, X= X, Y= Y, Z= The maximum velocity of water flow occurs in pipe 8 at 10.69 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 8 at 10.69 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.874 1.00 4.00 3.00 1.00 1.00 5.00 2.00 0.00 0.00 0.00 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 PAGE: K MATERIAL: Copper Tube-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 0.995 1.00 2.00 6.00 2.00 2.00 6.00 0.00 0.00 0.00 0.00 PAGE: L MATERIAL: Copper Tube-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.505 2.00 4.00 9.00 3.00 3.00 10.00 0.00 0.00 0.00 0.00 PAGE: P MATERIAL: PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVlv X Y Z 1.590 2.00 9.00 8.00 1.00 1.00 14.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.8.0 computer program (License No. 50081444) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.02 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.01 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 4 of 55.1 psi and a 7 minute flow of 175 gal. and a 10 minute flow of 250.0 gallons. The minimum pressure at any node is 18.0 psi at node 13. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 5 WATER SUPPLY CURVE 0 0.0 4 9.0 8 18.0 12 27.0 16 36.0 20 45.0 24 54.0 28 63.0 32 72.0 36 81.0 40 90.0 P R E S S U R E ( P S I ) Static = 87.2 psi, Residual = 82.1 psi @ 1550 gpm (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply 87.2 psi @ 25.0 gpm A B = Required Water Supply 55.1 psi @ 25.0 gpm B C = Available Water Supply 87.2 psi @ 25.0 gpm C D = Required Water Supply 55.1 psi @ 25.0 gpm D FLOW (GPM) DATE: 7/30/2020 S:\2020\31991\CALC\31991-00.rdf Page 6 DESIGN & DEVELOPMENT DEPARTMENT 78-495 Calle Tampico La Quinta, California 92253 (760) 777-7125 / FAX (760) 777-7011 OFFICE USE ONLY: REVIEW DATE: ______________  APPROVED  CORRECTIONS CALLED FOR PICKUP:_________ PICKED UP:_________________  SUBMITTAL #_________  REVISION #________ PERMIT NO. APPLICANT/OWNER INFORMATION Applicant Name: Owner Name: Mailing Address: Site Address: Phone Number: Project Email: Description: (Include # of sprinkler heads) Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City’s fire department, and the County designee serves as the City’s fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. CONTRACTOR INFORMATION Contractor Name: Contractor #: Signature: Contact Person: Mailing Address: Print Name: City, State, Zip: Phone Number: Business License #: Email Address:  ------------  HOURLY@161/HR  $670  HOURLY@161/HR  $791  $992  $418  $1234  HOURLY@161/HR $418 ------------  HOURLY@161/HR $418  $498  $740  $579  HOURLY@161/HR  ------------  HOURLY@161/HR  $176  $901  $257 HOURLY@161/HR  $337  $659  $590  $579  $418  $418  $161  $1062  HOURLY@161/HR OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org August 17, 2020 FIRE SPRINKLER SYSTEMS INC 705 E Harrison St #200 Corona, CA 92879 Re: Residential Fire Sprinkler Plan Review – MURAKAMI SCULL RESIDENCE FSS2020-0107 / 78995 DRY CREEK ROAD, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78995 DRY CREEK ROAD PERMIT#: FSS2020-0107 DATE ISSUED: 8/17/2020 DESCRIPTION: SCULL RESIDENCE CONTRACTOR: FIRE SPRINKLER SYSTEMS INC. HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.