FSS2022-0208ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST #C THOUSAND PALMS CA 92276 (760)404-1350 jpaulus@shastafire.co m CONTRACTOR SHASTA FIRE PROTECTION INC 72120 NORTHSHORE ST #C THOUSAND PALMS CA 92276 (760)404-1350 jpaulus@shastafire.co m OWNER DOYLE HENDERSON 77734 COUNTRY CLUB DR STE K PALM DESERT CA 92203 (760)404-1350 CONDITIONS Description: DESIGN & INSTALL AN AUTO FIRE SPKR SYSTEM IN NEW RESIDENCE Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: APPROVED Applied: 6/2/2022 ECON Parcel No: 774062017 Site Address: 53085 AVENIDA MENDOZA LA QUINTA,CA 92253 Approved: 7/8/2022 KHET Subdivision: SANTA CARMELITA VALE LA QUINTA UNIT 20 Block: 207 Lot: 5 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $5,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, April 13, 2023 2:12:33 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0208 BOND INFORMATION INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 6/2/2022 6/16/2022 7/8/2022 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH – ETRAKIT (1 DAY) PERMIT TECH BUCKET 6/2/2022 6/3/2022 6/3/2022 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $167.00 $167.00 7/8/22 WEB12453 CREDIT 476633 JLIM FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $250.00 $250.00 7/8/22 WEB12453 CREDIT 476633 JLIM Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/8/22 WEB12453 CREDIT 476633 JLIM Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/8/22 WEB12453 CREDIT 476633 JLIM Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Thursday, April 13, 2023 2:12:33 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0208 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/2/2022 Etrakit Contractor 1ST SUBMITTAL - PLAN SET 22-018 FIRE DEPT SUBMITTAL 6-2-22.pdf 1 DOC 6/2/2022 Etrakit Contractor 1ST SUBMITTAL - SINGLE HEAD HYD CALC 22-018 RESIDENTIAL SINGLE HD HYD CALC.pdf 1 DOC 6/2/2022 Etrakit Contractor 1ST SUBMITTAL - TWO HEAD HYD CALC 22-018 RESIDENTIAL TWO HD HYD CALC.pdf 1 DOC 6/2/2022 Etrakit Contractor 1ST SUBMITTAL - RCCE FORM FROM CVWD RCCE FORM.pdf 1 DOC 6/2/2022 Etrakit Contractor 1ST SUBMITTAL - CUT SHEETS VIKING FREEDOM RES CONC SSP VK494.pdf 1 DOC 6/2/2022 Etrakit Contractor 1ST SUBMITTAL - CUT SHEETS VIKING QR MIRAGE CONC SSP VK465.pdf 1 DOC 6/2/2022 Etrakit Contractor 1ST SUBMITTAL - APPLICATION LA QUINTA RESIDENTIAL PLAN REVIEW APP.pdf 1 DOC 7/8/2022 KOHL HETRICK FSS2022-0208 - APPROVED PLANS AND CALCS.pdf FSS2022-0208 - APPROVED PLANS AND CALCS.pdf 1 DOC 7/8/2022 KOHL HETRICK FSS2022-0208 - COA AND JOB CARD.pdf FSS2022-0208 - COA AND JOB CARD.pdf 1 Printed: Thursday, April 13, 2023 2:12:33 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2022-0208 APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST07/08/2022 9:34:10 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FSS2022-0208Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109 SHASTA FIRE PROTECTION, IN C. 72120 NORTHSHORE STREET STE . C THOUSAND PALMS,CA 92276 HYDRAULIC CALCULATION FOR : URBAN WORKX RESIDENCE 53-085 AVENIDA MENDOZA LA QUINTA, CALIFORNIA DRAWING NUMBER: 1of1 DATE: 4-26-22 -DESIGN DATA- REMOTE AREA LOCATION: MASTER BEDROOM OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: 0.05 gpm/sq. ft. AREA OF APPLICATION: TWO HEAD HYD. CALC. COVERAGE PER SPRINKLER: 256 sq. ft. TYPE OF SPRINKLERS CALCULATED: RESIDENTIAL "SSP" K =4.9 NUMBER OF SPRINKLERS CALCULATED: 2 DOMESTIC DEMAND: 5 gpm TOTAL SPKR DEMAND INCLUDING DOMESTIC DEMAND @ SOUR CE: 31.2 gpm @ 27.5 psi NOTE: SOURCE NODE IS AT DISCHARGE SIDE OF PROPOSED WATER METER SPRINKLER DEMAND AT BASE OF RISER (HYD NODE #5): 2 6.2 gpm @ 22.1 psi NOTE: HYD NODE #5 IS AT DOMESTIC WATER SUPPLY INTE RSECTION TO FIRE SYSTEM TYPE OF SYSTEM: WET WATER SUPPLY Source: CVWD STATIC PRESSURE ANALYSIS Date: 4-21-2022 Static: 106.0 psi INSTALLING CONTRACTOR Name: SHASTA FIRE PROTECTION,INC. Address: 72120 NORTHSHORE STREET (STE. C) THOUS AND PALMS, CA. 92276 Phone:(760) 404-1350 CALIF. STATE LIC NO. 47 6633 NAME OF DESIGNER: JOHN PAULUS AUTHORITY HAVING JURISDICTION: CITY OF LA QUINTA F IRE PREVENTION NOTES: Calculations performed by HASS under license # 16090901, granted by HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 2 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 WATER SUPPLY ANALYSIS Static: 106.00 psi Resid: 90.00 psi Flow: 100.0 gpm -14.7 0.0 20.0 40.0 60.0 80.0 100.0 120.0 20 30 40 50 60 70 80 90 100 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results G A U G E P R E S S U R E ( p s i ) A 1 2 B LEGEND 1 Available pressure 104.15 psi @ 31.2 gpm 2 Required pressure 27.52 psi @ 31.2 gpm A. Source Supply Curve B. System Demand Curve SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 3 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. T OTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ D EMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 106.0 90.0 100.0 104.1 31.2 27.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE D ISCHARGE NOTES (FT) (PSI) (GPM) 2 0.0 - - - - 25.6 - - - 3 0.0 - - - - 23.5 - - - 4 0.5 - - - - 22.9 - - - 5 2.0 HOSE STREAM 22.1 5.0 6 10.5 - - - - 17.0 - - - 7 10.5 - - - - 16.8 - - - 8 10.5 - - - - 13.3 - - - 9 10.5 - - - - 7.5 - - - 10 10.5 - - - - 13.3 - - - 11 10.5 - - - - 13.3 - - - 101 10.0 K= 4.90 7.3 13.2 102 10.0 K= 4.90 7.0 13.0 103 10.0 - - - - 13.5 - - - SOURCE 0.0 SOURCE 27.5 31.2 SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 4 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 NFPA5 PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 2.50 120 1.9 SOURCE 0.0 27.5 31.2 3 1.000 C : 5.3 5.56 -0.0 2 0.0 25.6 31.2 1.101 G : 0.3 8.06 0.234 1.9 Pipe: 2 0.0 0.0 25.00 150 2.1 2 0.0 25.6 31.2 4 F1.250 2E :16.0 18.00 -0.0 3 0.0 23.5 31.2 1.394 2K : 2.0 43.00 0.049 2.1 Pipe: 3 0.0 0.0 2.00 150 0.6 3 0.0 23.5 31.2 5 L1.250 E : 3.0 3.00 0.2 4 0.5 22.9 31.2 1.265 5.00 0.079 0.4 Pipe: 4 H.S. 5.0 Disch 1.50 120 0.8 4 0.5 22.9 26.2 6 O1.250 G : 1.2 1.17 0.6 5 2.0 22.1 31.2 1.425 2.67 0.067 0.2 Pipe: 5 0.0 0.0 E: 3.5 9.50 120 5.0 5 2.0 22.1 26.2 7 O1.250 T : 7.0 18.70 3.7 6 10.5 17.0 26.2 1.425 C : 8.2 28.20 0.048 1.4 Pipe: 6 0.0 0.0 1.50 120 0.2 6 10.5 17.0 26.2 8 O1.250 E : 3.5 3.51 -0.0 7 10.5 16.8 26.2 1.425 5.01 0.048 0.2 Pipe: 7 0.0 0.0 22.67 150 3.5 7 10.5 16.8 26.2 9 F1.000 E : 7.0 8.70 -0.0 8 10.5 13.3 26.2 1.101 R : 1.7 31.37 0.112 3.5 Pipe: 8 0.0 13.0 102 40.50 150 5.8 8 10.5 13.3 13.2 101 F1.000 T : 6.0 11.10 -0.0 9 10.5 7.5 26.2 1.101 3R : 5.1 51.60 0.112 5.8 Pipe: 9 4.90 13.2 Disch 1.08 150 0.2 9 10.5 7.5 0.0 F1.000 E : 7.0 13.00 -0.2 101 10.0 7.3 13.2 1.101 T : 6.0 14.08 0.032 0.4 Pipe: 10 4.90 13.0 Disch 8.92 150 0.5 9 10.5 7.5 0.0 F1.000 E : 7.0 13.00 -0.2 102 10.0 7.0 13.0 1.101 T : 6.0 21.92 0.031 0.7 Pipe: 11 0.0 0.0 27.25 150 0.0 10 10.5 13.3 0.0 F1.000 4R : 6.8 6.80 -0.0 8 10.5 13.3 0.0 1.101 34.05 0.000 0.0 Pipe: 12 0.0 0.0 30.33 150 -0.0 11 10.5 13.3 0.0 F1.000 E : 7.0 12.10 -0.0 10 10.5 13.3 0.0 1.101 3R : 5.1 42.43 0.000 0.0 Pipe: 13 0.0 0.0 1.25 150 0.2 103 10.0 13.5 0.0 F1.000 E : 7.0 13.00 0.2 11 10.5 13.3 0.0 1.101 T : 6.0 14.25 0.000 0.0 SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 5 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 NOTES (HASS): (1) Calculations were performed by the HASS 2021 D computer program in accordance with NFPA13 (2020) under license no. 64617362 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an a verage imbalance at each node of 0.008 gpm and a maxi mum imbalance at any node of 0.106 gpm. (3) Total pressure at each node is used in balanci ng the system. Maximum water velocity is 10.5 ft/sec at pipe 1. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculat ion report. (5) Available pressure at source node SOURCE under full flow conditions is 99.58 psi with a flow of 61.04 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Fee t (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVlv Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.0 0 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.0 0 0.80 PAGE: J MATERIAL: CPVC Tyco/NFPA HWC: 150 Diameter Equivalent Fitting Lengths in Fee t (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVlv Gate 1.101 1.00 5.00 5.00 1.00 1.00 8.0 0 0.40 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Fee t (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 1.265 3.00 6.00 1.00 2.00 0.50 7.0 0 0.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 6 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 PAGE: O MATERIAL: Eddythread 40 HWC: 120 Diameter Equivalent Fitting Lengths in Fee t (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.425 3.51 7.01 2.34 8.18 7.01 1.1 7 11.69 11.69 7.01 SHASTA FIRE PROTECTION, IN C. 72120 NORTHSHORE STREET STE . C THOUSAND PALMS,CA 92276 HYDRAULIC CALCULATION FOR : URBAN WORKX RESIDENCE 53-085 AVENIDA MENDOZA LA QUINTA, CALIFORNIA DRAWING NUMBER: 1of1 DATE: 4-26-22 -DESIGN DATA- REMOTE AREA LOCATION: BEDROOM OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: 0.05 gpm/sq. ft. AREA OF APPLICATION: ONE HEAD HYD. CALC. COVERAGE PER SPRINKLER: 324 sq. ft. TYPE OF SPRINKLERS CALCULATED: RESIDENTIAL "SSP" K =4.9 NUMBER OF SPRINKLERS CALCULATED: 1 DOMESTIC DEMAND: 5 gpm TOTAL SPKR DEMAND INCLUDING DOMESTIC DEMAND @ SOUR CE: 22.0 gpm @ 25.6 psi NOTE: SOURCE NODE IS AT DISCHARGE SIDE OF PROPOSED WATER METER SPRINKLER DEMAND AT BASE OF RISER (HYD NODE #5): 1 7.0 gpm @ 22.4 psi NOTE: HYD NODE #5 IS AT DOMESTIC WATER SUPPLY INTE RSECTION TO FIRE SYSTEM TYPE OF SYSTEM: WET WATER SUPPLY Source: CVWD STATIC PRESSURE ANALYSIS Date: 4-21-2022 Static: 106.0 psi INSTALLING CONTRACTOR Name: SHASTA FIRE PROTECTION,INC. Address: 72120 NORTHSHORE STREET (STE. C) THOUS AND PALMS, CA. 92276 Phone:(760) 404-1350 CALIF. STATE LIC NO. 47 6633 NAME OF DESIGNER: JOHN PAULUS AUTHORITY HAVING JURISDICTION: CITY OF LA QUINTA F IRE PREVENTION NOTES: Calculations performed by HASS under license # 16090901, granted by HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 2 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 WATER SUPPLY ANALYSIS Static: 106.00 psi Resid: 90.00 psi Flow: 100.0 gpm -14.7 0.0 20.0 40.0 60.0 80.0 100.0 120.0 20 30 40 50 60 70 80 90 100 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results G A U G E P R E S S U R E ( p s i ) A 1 2 B LEGEND 1 Available pressure 105.03 psi @ 22.0 gpm 2 Required pressure 25.63 psi @ 22.0 gpm A. Source Supply Curve B. System Demand Curve SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 3 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. T OTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ D EMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 106.0 90.0 100.0 105.0 22.0 25.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 22.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 17.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE D ISCHARGE NOTES (FT) (PSI) (GPM) 2 0.0 - - - - 24.6 - - - 3 0.0 - - - - 23.5 - - - 4 0.5 - - - - 23.1 - - - 5 2.0 HOSE STREAM 22.4 5.0 6 10.5 - - - - 18.1 - - - 7 10.5 - - - - 18.0 - - - 8 10.5 - - - - 16.4 - - - 9 10.5 - - - - 16.4 - - - 10 10.5 - - - - 14.7 - - - 11 10.5 - - - - 12.5 - - - 101 10.0 - - - - 16.6 - - - 102 10.0 - - - - 16.6 - - - 103 10.0 K= 4.90 12.0 17.0 SOURCE 0.0 SOURCE 25.6 22.0 SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 4 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 NFPA5 PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 2.50 120 1.0 SOURCE 0.0 25.6 22.0 3 1.000 C : 5.3 5.56 -0.0 2 0.0 24.6 22.0 1.101 G : 0.3 8.06 0.122 1.0 Pipe: 2 0.0 0.0 25.00 150 1.1 2 0.0 24.6 22.0 4 F1.250 2E :16.0 18.00 -0.0 3 0.0 23.5 22.0 1.394 2K : 2.0 43.00 0.026 1.1 Pipe: 3 0.0 0.0 2.00 150 0.4 3 0.0 23.5 22.0 5 L1.250 E : 3.0 3.00 0.2 4 0.5 23.1 22.0 1.265 5.00 0.041 0.2 Pipe: 4 H.S. 5.0 Disch 1.50 120 0.7 4 0.5 23.1 17.0 6 O1.250 G : 1.2 1.17 0.6 5 2.0 22.4 22.0 1.425 2.67 0.035 0.1 Pipe: 5 0.0 0.0 E: 3.5 9.50 120 4.3 5 2.0 22.4 17.0 7 O1.250 T : 7.0 18.70 3.7 6 10.5 18.1 17.0 1.425 C : 8.2 28.20 0.022 0.6 Pipe: 6 0.0 0.0 1.50 120 0.1 6 10.5 18.1 17.0 8 O1.250 E : 3.5 3.51 -0.0 7 10.5 18.0 17.0 1.425 5.01 0.022 0.1 Pipe: 7 0.0 17.0 10 22.67 150 1.6 7 10.5 18.0 0.0 9 F1.000 E : 7.0 8.70 -0.0 8 10.5 16.4 17.0 1.101 R : 1.7 31.37 0.050 1.6 Pipe: 7A 0.0 0.0 40.50 150 0.0 8 10.5 16.4 0.0 F1.000 T : 6.0 11.10 -0.0 9 10.5 16.4 0.0 1.101 3R : 5.1 51.60 0.000 0.0 Pipe: 8 0.0 0.0 1.08 150 0.2 101 10.0 16.6 0.0 F1.000 E : 7.0 13.00 0.2 9 10.5 16.4 0.0 1.101 T : 6.0 14.08 0.000 0.0 Pipe: 9 0.0 0.0 8.92 150 0.2 102 10.0 16.6 0.0 F1.000 E : 7.0 13.00 0.2 9 10.5 16.4 0.0 1.101 T : 6.0 21.92 0.000 0.0 Pipe: 10 0.0 0.0 27.25 150 1.7 8 10.5 16.4 17.0 11 F1.000 4R : 6.8 6.80 -0.0 10 10.5 14.7 17.0 1.101 34.05 0.050 1.7 Pipe: 11 0.0 0.0 30.33 150 2.1 10 10.5 14.7 17.0 103 F1.000 E : 7.0 12.10 -0.0 11 10.5 12.5 17.0 1.101 3R : 5.1 42.43 0.050 2.1 Pipe: 12 4.90 17.0 Disch 1.25 150 0.5 11 10.5 12.5 0.0 F1.000 E : 7.0 13.00 -0.2 103 10.0 12.0 17.0 1.101 T : 6.0 14.25 0.050 0.7 SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 5 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 NOTES (HASS): (1) Calculations were performed by the HASS 2021 D computer program in accordance with NFPA13 (2020) under license no. 64617362 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an a verage imbalance at each node of 0.011 gpm and a maxi mum imbalance at any node of 0.146 gpm. (3) Total pressure at each node is used in balanci ng the system. Maximum water velocity is 7.4 ft/sec at pipe 1 . (4) Items listed in bold print on the cover sheet are automatically transferred from the calculat ion report. (5) Available pressure at source node SOURCE under full flow conditions is 102.66 psi with a flow of 42.91 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Fee t (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVlv Gate 1.101 1.40 7.00 6.00 1.70 1.00 8.0 0 0.40 1.394 1.80 8.00 7.30 2.30 1.00 11.0 0 0.80 PAGE: J MATERIAL: CPVC Tyco/NFPA HWC: 150 Diameter Equivalent Fitting Lengths in Fee t (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVlv Gate 1.101 1.00 5.00 5.00 1.00 1.00 8.0 0 0.40 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Fee t (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 1.265 3.00 6.00 1.00 2.00 0.50 7.0 0 0.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANAL YSIS Page 6 DATE: 4/26/2022 HYD CALC FOLDER\2-018 URBAN WORKX RESIDENCE 4-26-22.SDF JOB TITLE: URBAN WORKX RESIDENCE HYD CALC 22-018 4-26-22 PAGE: O MATERIAL: Eddythread 40 HWC: 120 Diameter Equivalent Fitting Lengths in Fee t (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.425 3.51 7.01 2.34 8.18 7.01 1.1 7 11.69 11.69 7.01 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org July 8, 2022 Shasta Fire Protection 72120 Northshore Street #C Thousand Palms, CA 92276 Re: Residential Fire Sprinkler Plan Review – AVENIDA MENDOZA RES. FSS2022-0208 / 53085 AVENIDA MENDOZA, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53085 AVENIDA MENDOZA PERMIT#: FSS2022-0208 DATE ISSUED: 7/8/2022 DESCRIPTION: MENDOZA RESIDENCE CONTRACTOR: SHASTA FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.