12-1462 (SFD) Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr & Mrs Richard Albers 80-270 Via Capri The Hideaway La Quinta, CA 92253 Project Designer: Residential Concepts 80-270 Via Capri The Hideaway La Quinta, CA 92253 (760) 342-1709 w Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77=085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 CITY OF LA QUINTA BUILDING & SAFETY DEPT.' APPROVED FOR CONSTRUCTIO DA . 2 Z li:�' BY �SCd Job Number: 12- l2 aF 11VED Date: DEC 2'0 2012 12/4/2012 BY: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.onergysoft.com. " EnergyPro 5.1 byEnergySoft User Number. 6712 RunCode: 2012-12-04714:08:24 ID: 4 �4_ ..ryY � �4 . Y � � � _ - � � � - 1„ � F 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr & Mrs Richard Albers Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 12/4/2012 Project Address 80-270 Via Capri The Hideaway La Quint California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 5,06 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST I I Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,976 Radiant Barrier New Wall Wood Framed R-21 3,899 New Slab Unheated Slab -on -Grade None 5,003 Perim = 415' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 4.0 0.550 0.67 none none None New Left (Kq 128.0 0.530 0.46 none none Bug Screen New Skylight 16.0 0.550 0.67 none none None , New Rear (N) 400.0 0.530 0.46 none none Bug Screen New Rear (NE) 80.0 0.530 0.46 none none Bug Screen New Front (S) 170.0 0.530 0.46 none none Bug Screen New Left (NKK 80.0 0.530 0.46 none none Bug Screen New Skylight 4.0 0.550 0.67 none none None New Right (E) 12.0 0.530 0.46 none none Bug Screen New Front (SlAq 68.0 0.530 0.46 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.3 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.3 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.61 No Pipe Insulation New EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-04714:08:24 ID: Page 3 of 29 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr & Mrs Richard Albers Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 12/4/2012 Project Address 80-270 Via Capri The Hideaway La Quint California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,000 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201 2-12-04 714:08:24 /D: Page 4 of 29 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Mr & Mrs Richard Albers Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1121412012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A endix R43.3 must be met. H GH MASS' Design - Verify Thermal Mass: 646.0 ft2 Covered Slab"'Floor, 3.500" thick at Bedroom 2'& 3 HIGH MASS Design -Verity Thermal Mass: 160.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3 The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MAS Design - Verify Thermal Mass: 630.0 ft2 Covered Slab Floor, 3.500" thick at Family Great Kitchen HIGH MASS Design - Verify Thermal Mass: 1, 724.0 ft2 Exposed Slab Floor, 3.500" thick at Family Great Kitchen The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat. In addition the air flow re uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -'Verify Thermal Mass: 949.0 ft2 Covered Slab Floor, 3.500" thick at Master HIGH MASS Design - Verity Thermal Mass: 462.0 ft2 Exposed Slab Floor, 3.500" thick at Master The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate t hermostat. In addition the air flow re uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. H GH MASS Design - Verify Therm6l Mass: 2:0 ft2 Covered Slab Floor, 3.500" thick at Casita 33 HIGH MASS Design - Verify Thermal Mass: 100.0 112 Exposed Slab Floor, 3.500" thick at Casita The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System York CZF030 TM8LX060Al2MP11 includes credit for a 13.3 EER Condenser A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System York CZF060 TM8LX100Al2MP11 includes credit for a 13.3 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System York CZF048 TMBLX100C20MP11 includes credit for a 13.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct ' leakage meets the specified criteria. The Cooling System York YCJD18 TMBLX060Al2MP11 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. I—E-n—emyPro 5.1 by EnerqySoft User Number., 6712 RunCode: 2012-12-04714:08:24 ID: Page 5 of 29 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr & Mrs Richard Albers ❑ Multi Family ❑ Existing+'Addition/Alterationz 12/4/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.70 4.60. -0.91 Space Cooling 55.53 45.99 9.53 Fans 11.22 14.93 -3.71 Domestic Hot Water 7.30 7.07 0.23 Pumps 0.00 0.00 0.00 Totals 77.74 72.59 5.15 Percent Better Than Standard: 6.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 1,292 238 Fuel Available at Site: Natural Gas (W 1,258 208 Raised Floor Area: 0 (N) 1,259 480 Slab on Grade Area: 5,003 (E) 1,052 12 Average Ceiling Height: 11.9 Roof 5,000 24 Fenestration Average U -Factor: 0.53 TOTAL: 962 Average SHGC: 0.46 Fenestration/CFA Ratio: 19.2% REMARKS The Hideaway Lot # 54 & 55 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, r` 12/4/2012 Jon Scott Address 77-085 Michigan Drive Name V City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct.design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Residential Concepts Address 80-270 Via Capri The Hideaway Name Jerry W. Sherman City/State/Zip La Quinta, CA 92253 Phone (760) 3424709 S ned License # Date EnergyPro 5.1 by EnerqySoft user Number: 6712 Runcode: 2012-12-04714:08:24 ID: Page 6 of 29 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr & Mrs Richard Albers Building Type m Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1121412012 OPAQUE SURFACE DETAILS Surface T e Area U- Insulation Joint Appendix I Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 802 0.026 R-38 0 20 New 4.2.1-A9 Bedroom 2 & 3 Wall 55 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 2 & 3 Well 336 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 348 0.069 R-21 270 90 New 4.3.1-A6 Bedroom 2 & 3 Slab 646 d. 730 None 0 180 New 4.4.7-A1 Bedroom 2 & 3 Slab 166 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 & 3 Roof 2,338 0.026 R-38' 0 20 New 4.2.1-A9 Family Great Kitchen Wall 482 0.069 R-21 0 90 New 4.3.1-A6 Family Great Kitchen Wall 102 0.069 R-21 1 45 90 New 4.3.1-A6 Family Great Kitchen Wall 196 0.069 R-21 90 90 1 New 4.3.1-A6 Family Great Kitchen Wall 414 0.069 R-21 180 90 New 4.3.1-A6 Family Great Kitchen Door 24 0.500 None 180 90 New 4.5.1-A4 Family Great Kitchen Wall 490 0.069 R-21 270 90 New 4.3.1-A6 Family Great Kitchen Wall 102 0.069 R-21 315 90 New 4.3.1-A6 Familz Great Kitchen Slab 630 0.730 None 0 180 New 4.4.7-A1 Family Great Kitchen -family Slab 1,724 0.730 None 0 180 New 4.4.7-A1 Great Kitchen FENESTRATION SURFACE DETAILS ID Type Area I LI -Factor' SHGCz Azm Status Glazing Type Location/Comments 1 Skylight 4.0 0.550 Default 0.67 Default 0 New Double Non Metal Clear Bedroom 2 & 3 2 Window 30.0 0.530 1 NFRC 0.46 NFRC 270 New Dual Metal Tint Bedroom 2 & 3 3 Window 48.0 0.530 1 NFRC 0.46 NFRC 270 New Dual Metal Tint Bedroom 2 & 3 4 Skylight Default 16.0P0.530 0.67 Default 0 New Double Non Metal Clear Family Great Kitchen 5 Window 120.0 NFRC 0.46 NFRC 0 New Dual Metal Tint Family Great Kitchen 6 Window 120.0 NFRC 0.46 NFRC 0 New Dual Metal Tint Family Great Kitchen 7 Window 36.0 NFRC 0.46 NFRC 0 New Dual Metal Tint Family Great Kitchen 8 Window 80.0 NFRC 0.46 NFRC 45 New Dual Metal Tint Family Great Kitchen 9 Window 24.0 NFRC 0.46 NFRC 180 New Dual Metal Tint Family Great Kitchen 10 Window 6.0 0.530 NFRC 0.46 NFRC 180 New Dual Metal Tint Family Great Kitchen 11 Window 60.0 0.530 NFRC 0.46 NFRC 180 New Dual Metal Tint Family Great Kitchen 12 Window 80.0 0.530 NFRC 0.46 NFRC 180 New Dual Metal Tint Family Great Kitchen 13 Window 80.0 0.530 NFRC 0.46 NFRC 315 New Dual Metal Tint Family Great Kitchen 14 Skylight 4.0 0.550 Default 0.67 Default 0 New I Double Non Metal Clear Master 15 Window 120.0 0.530 NFRC 0.461NFRC 1 0 New I Dual Metal Tint Master 16 Window 4.0 0.530 NFRC 0.46 NFRC 1 0 New I Dual Metal Tint Master (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right in H t Dist Len Hat 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 lNone 1.00 5 Bug Screen 0.76 6 Buq Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 None 1.00 15 Buq Screen 0.76 16 Bug Screen 1 0.76 EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 7 of 29 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 25L__ CF -1 R Project Name Mr & Mrs Richard Albers Building Type 0 Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 12/4/2012 OPAQUE SURFACE DETAILS Surface LI Insulation Joint Appendix Type Area Factor CavitYTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,404 0.026 R-38 0 20 New 4.2.1-A9 Master Wall 140 0.069 R-21 0 90 New 4.3.1-A6 Master Wall 608 0.069 R-21 90 90 New 4.3.1-A6 Master Wall 88 0.069 R-21 180 90 New 4.3.1-A6 Master Slab 949 0.730 None 0 180 New 4.4.7-A1 Master Slab 462 0.730 None 0 186 New 4.4.7-A1 Master Roof 432 0.026 R-38 0 20 New 4.2.1-A9 Casita Wall 236 0.069 R-21 90 90 New 4.3.1-A6 Casita Wall 100 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 921 0.069 R-21 225 90 New 4.3.1-A6 Casita Wall 110 0.069 R-21 270 90 New 4.3.1-A6 Casita Slab 332 0.730 None 0 186 New 4.4.7-A 1 Casita Slab 160 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0 0.530 NFRC 0.46 NFRC 90 New Dual Metal Tint Master 18 Window 4.0 0.530 NFRC 0.46 NFRC 90 New Dual Metal Tint Master 19 Window 4.0 0.530 NFRC 0.46 NFRC 90 New Dual Metal Tint Casita 20 Window 68.6 0.530 NFRC 0.46 NFRC 225 New Dual Metal Tint Casita 21 Window 50.0 0.530 NFRC 0.46 NFRC 270 New Dual Metal Tint Casita (1) LI -Factor Type: 1161 = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC HqA Wd Ove hang Len H t LExt RExt Left Fin Dist Len Right in H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 EnefgyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 8 of 29 • • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Mr & Mrs Richard Albers Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 12/4/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Bedroom 2 8 3 806 8,060 HVAC 2 & 3 Family Great Kitchen 2,354 32,956 HVAC 4 Master 1,408 14,080 HVAC 5 Casita 432 4,320 Totals 51000 0 01. 0 'HVAC SYSTEMS System Name Qty. HeatingT e Min. Eff. CoolingType Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.3 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE S lit Air Conditioner 16.0 SEER Setback New HVAC 4 1 Central Furnace 80 % AFUE Split Air Conditioner 16.3 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 d New HVAC 5 1 Ducted Ducted JAttic, Ceiling Ins, vented 4.21 El I New WATER HEATING SYSTEMS S stem Name O Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status G50T236 American Stand 1 Small Gas No Pipe Insulation 40,000 50 0.61 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING Control O . HP Hot Water Piping Length ft N a System Name Pipe Length Pipe Diameter Insul. Thick. Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-04T14:08:24 ID: Page 9 of 29 MANDATORY MEASURES SUMMARY: Residential (Pagel of -3 M Project Name " Mr & Mrs Richard Albers .-1R Date 12/4/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulatinq Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the•CF-1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent LI-factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. ' *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI-factor. 4150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. &150(q): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliance s and Gas Log Measures: 150 e 1 A: Masonry or factory -built file laces have a closable metal or qlass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readilyaccessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. ` §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. ` §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine Iines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. - 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture a ui ment maintenance and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(m)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 10 of 29 • C MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr & Mrs Richard Albers 12/4/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than'sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes' unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation acid Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(6)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 6114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets'that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust.fans, in rooms other than kitchens shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2012-12-04714:08:24 ID: Page 11 of 29 0 0 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr & Mrs Richard Albers 92/4/2092 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housin .and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy. luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. I EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 12 of 29 • 0 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr & Mrs Richard Albers Date 12/4/2012 System Name HVAC 1 Floor Area 806 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,018 16,404 Return Vented Lighting 0 Return Air Ducts 1,391 Return Fan 0 Ventilation F 0 0 Supply Fan 0 Supply Air Ducts 1,391 TOTAL SYSTEM LOAD 1 19,186 COIL HTG. Latent CFM 1,6301 200 0 0 1,630 PEAK Heating System Sensible Output perSystem 51,000 9,916 Total Output Btuh 51,000 Output Btuh/ ft 63.3 705 Cooling System 0 Output perSystem 28,500 0 Total Output Btuh 28,500 0 Total Output ons 2.4 705 Total Output Btuh/s ft 35.4 Total Output s ft/Ton 339.4 11,325 Air System CFM perSystem 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 York CZF030TM8L.X060Al2MP11 18,892 Total Adjusted System Output 18,8921 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 4,553 51,000 4,553 51,000 Aug 3 PM I Jan 1 AM Airflow cfm/s ft 124 Airflow cfm/Ton 421.1 Outside Air % 0.0%1 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF Outside Air 0 cfm Supply Fan AL 1,000 cfm 71 of 71 OF 119 OF Heating Coil 119 OF -- ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78 OF 71!60°F 71/60°F 54/53°F o Outside Air Ar 0 cfm Supply Fan Cooling Coil 1,000 cfm 54.8% 71 / 60 OF 55 / 53 OF ROOM 701 60 OF �E�,eyPro 5.1 by EnergySoff User Number. 6712 RunCode: 2012-12-04714:08:24 ID: Page 13 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY .Project Name Mr & Mrs Richard Albers Date 12/4/2012 System Name HVAC 2 & 3 Floor Area 2,354 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 1,872 36,068 3,608 841 Return Vented Lighting 0 Return Air Ducts 3,058 Return Fan o Ventilation 0 0 0 0 Supply Fan 0 Supply Air Ducts 3,058 TOTAL SYSTEM LOAD 1 42,185 3,608 PEAK Heating System Sensible Output erSystem 89,000 36,344 Total Output Btuh 178,000 Output Btuh/s ft 75.6 2,582 Cooling System 0 Output erSystem 58,500 0 Total Output Btuh 117,000 0 Total Output ons 9.8 2,582 Total Output Btuh/s ft 49.7 Total Output s ftrron 241.4 1 41,509 Air System - CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 York CZF060 TM8l_X100Al2MP11 83,204 10,518 178,000 1 178,000 Jan 1 AM Alrflow cfm/s ft 1.70 Airflow cfmrron 410.3 Outside Air % 0.0% Total Adjusted System Output 1 83,204 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 10,518 Aug 3 PM Outside Alr cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF Outside Air 0 cfm Supply Fan 4,000 cfm 71 OF 71 OF 113 OF Heating Coil 113 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71158°F 71 /58°F 51 /50°F o _ Outside Air Ar 0 cfm Supply Fan Cooling Coil 4,000 cfm 48.9% 71 158 of 52 / 51 OF ,......__.................._............ R, . ROOM 70158 OF EnergyPro 5.1 by EnergySoff User Number.' 6712 RunCode: 2012-12-04714:08:24 ID: Page 14 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY .Project Name Mr & Mrs Richard Albers Date 12/4/2012 System Name HVAC 4 Floor Area 1,408 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 866 15,846 2,3991 340 Return Vented Lighting 0 Return Air Ducts 1,344 Return Fan 0 Ventilation 0 0 0 0 Supply Fan 0 Supply Air Ducts 1,344 TOTAL SYSTEM LOAD 1 18,533 2,399 PEAK Heating System Sensible Output per System 71,000 14,661 Total Out ut (li 71,000 Output Btuh/s ft 50.4 1,042 Cooling System 0 Output per System 46,500 0 Total Output Btuh 46,500 0 Total Output ons 3.9 1,042 Total Output Btuh/s ft 33.0 Total Output s ft/Ton 363.4 1 16,744 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 York CZF048TM8LX100C20MP11 31,957 5,691 71,000 Airflow cfm/s ft 1.14 Total Adjusted System Output 1 31,957 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,691 1 71,000 Aug 3 PM I Jan 1 AM Airflow cfm/Ton 412.9 Outside Air % 0.0% Outside Air cfm/s ft 0.00 values above given at ARI conditions •Note: HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF Outside Air 0 cfm Supply Fan 1,600 cfm 71 of 71 OF 1130F Heating Coil 112 OF --..------- ....... _ ROOM NJ 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak • 112/78°F 71 /59°F 71 /59°F 52/51 OF Outside Air 0 cfm Supply Fan Cooling Coil 1,600 cfm 51.5% 71 /59°F 53 / 51 OF ROOM -A 70/59°F EnergyPro5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-04714:08:24 ID: Page 15 of 29 All HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr & Mrs Richard Albers Date 12/4/2012 System Name HVAC 5 Floor Area 432 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 571 Return Vented Lighting Return Air Ducts Return Fan Ventilation o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK Sensible 10,642 0 902 0 0 0 902 1 12,4461 COIL HTG. Latent CFM 1,152 100 0 0 1,152 PEAK Heating System Sensible Output per System 51,000 8,334 Total Output Btuh 51,000 Output Btuh/s ft 118.1 592 Cooling System 0 Output per System 18,000 0 Total Output Btuh 18,000 0 Total Output ons 1.5 592 Total Output Btuh/s ft 41.7 Total Output s ft/Ton 288.0 9,518 Air System CFM per System 600 HVAC EQUIPMENT SELECTION Airflow cfm 600 York YCJD18TM8LX060Al2MP11 Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 12,991 12,991 1,549 51,000 1,549 51,000 Aug 3 PM I Jan 1 AM Airflow cfm/s ft 1.39 Airflow cfm/Ton 400.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF Outside Air 0 cfm Supply Fan 600 cfm 71 OF 71 OF 151 OF Heating Coil 150 OF — ROOM r M 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71 /59°F 71 /59°F 51 /50°F Outside Air c 0 cfm Supply Fan Cooling Coil 600 cfm 71 / 59 OF 3 52 / 51 OF 50.1 % ROOM -JI 70/ 58 OF EnergyPro 5.1 by EnergySoft User Number 6712 RunCode: 2012-12-04714:08:24 ID: Page 16 of 29 0 • • ROOM LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 12/4/2012 System Name Floor Area ' ' HVAC 1 806 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible I Latent CFM Sensible Bedroom 2 & 3 Bedroom 2 & 3 1 1 1,0181 16,4041 1,630 1,0181 16,4041 1,630 200 9,916 PAGE TOTAL TOTAL' 1,018 16,4041 1,6301 200 9,916 1,018 16,404 1,630 200 9,916 Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2 0 1 2-1 2-04 714:08:24 ID: Pae 17 of 29 ROOM LOAD SUMMARY Project Name . Mr & Mrs Richard Albers Date 12/4/2012 System Name HVAC 2 & 3 Floor Area 2,354 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Family Great Kitchen Family Great Kitchen 1 1,872 36,068 3,608 1,872 36,068 3,608 841 36,344 ' Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL ' 1,872 1,872 36,068 36,068 ,3,608 3,608 841 36,344 841 36,344 Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Pae 18 of 29 0 • • ROOM LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 12/4/2012 'System Name Floor Area HVAC 4 1,408 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible Latent CFM Sensible Latent CFM Sensible Master Master 1 866 15,846 2,399 866 15,846 2,399 340 14,661 ides ventilation load for zonal 5.1 by EnemySoR User N PAGE TOTAL TOTAL' 866 15,846 2,399 340 14,661 866 15,846 2,399 340 14,661 • ROOM LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 12/4/2012 System Name Floor Area HVAC 5 432 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I UNITSensible I Latent CFM Sensible Latent CFM Sensible LCasita Casita 1 571 10,642 1,152 � 571 10,642 1,152 1001 8,334 * Total includes PAGE TOTAL TOTAL* 571 10,6421 1,152 100 8,334 571 10,642 1,152 100 8,334 • • • ROOM HEATING PEAK LOADS Project Name Mr & Mrs Richard Albers Date 12/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Temperature Bedroom 2 & 3 806.0 ft' 72 OF Time of Peak Outdoor Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area U -Value - 802.0 X 0.0260 X 4.0 X 0.5500 X 739.0 X 0.0690 X 78.0 X 0.5300 X perim = 75.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X` X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 806 X 10.00 X 0.318 Area Ceiling Height ACH AT OF 46 = 46 = 46 = 46 = 46 = = = = = = = = = = = _ = = = = = = = = = = = = = Page Total /60] X 46 AT Btu/hr 959 101 2,346 1,902 2,519 7,826 = 2,090 R-38 Roof(R.38.2x 14.16) Double Non Metal Clear R-21 Wall (W.21.2x6.16) Dual Metal Tint Slab -On -Grade Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,916 Energ Pro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 91 of 29 • • • ROOM HEATING PEAK LOADS Project Name Date Mr & Mrs Richard Albers 12/4/2012 ' ROOM INFORMATION DESIGN CONDITIONS Room Name Family Great Kitchen Time of Peak Jan 1 AM Floor Area 2,354.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT °F Btu/hr R-38 Roof(R.38.2x14.16) 2,338.0 X 0.0260 X 46 = 2,796 Double Non Metal Clear 16.0 X 0.5500 X 46 = 405 R-21 Wall (W.21.2x6.16) 1,786.0 X 0.0690 X 46 = 5,669 Dual Metal Tint 606.0 X 0.5300 X 46 = 14,774 Wood Door 24.0 X 0.5000 X 46 = 552 Slab -On -Grade perim = 180.0 X 0.7300 X 46 = 6,044 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 30,240 Infiltration:[ 1.00 X 1.064 X 2,354 X 14.00 X 0:227 /60] X 46 = 6,104 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 36,344 EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 22 of 29 .0 ROOM HEATING PEAK LOADS Project Name Date Mr & Mrs Richard Albers 12/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Time of Peak Jan 1 AM Floor Area 1,408.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof(R. 38.2x 14.16) 1,404.0 X 0.0260 X 46 = 1,679 Double Non Metal Clear 4.0 X 0.5500 X 46 = 101 R-21 Wall (W.21.2x6.16) 836.0 X 0.0690 X 46 = 2,653 Dual Metal Tint 132.0 X 0.5300 X 46 = 3,218 Slab -On -Grade perim = 100.0 X 0.7300 X 46 = 3,358 X X — X X = X X _ X X = X X = X X = X X = x X = X X = X X — X X _ X X — X X _ X X = X X = X X = X X = X X X X = X X X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 11,010 Infiltration:[ 1.00 X 1.064 X 1,408 X 10.00 X 0.318 / 60 ] :X 46 = 3,651 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,661 EnergyPro 5.1 by Energ Soft User Number. 6712 RunCode: 2012-12-04714:08:24 ID: Page 23 of 29 C] • ROOM HEATING PEAK LOADS Project Name Date Mr & Mrs Richard Albers 12/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Time of Peak Jan 1 AM Floor Area 432.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area V -Value AT OF Btu/hr R-38 Roof(R.38.2x14.16) 432.0 X 0.0260 X 46 = 517 R-21 Wall (W.21.2x6.16) 538.0 X 0.0690 X 46 = 1,708 Dual Metal Tint 122.0 X 0.5300 X 46 = 2,974 Slab -On -Grade perim = 60.0 X 0.7300 X 46 = 2,015 X X = X X = X X = X X = X X = X X = X X = X . X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 7.213 Infiltration:[ 1.00 X 1.064 X 432 X 10.00 X 0.318 /60] X 46 = 1,120 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,334 Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 24 of 29 • C] RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 1214/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 & 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 806.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 802.0 X 0.0260 X 77.0 = 1,606 R-21 Wall (W.21.2x6.16) (N) 55.0 X 0.0690 X 31.0 = 118 R-21 Wall (W.21.2x6.16) (S) 336.0 X 0.0690 X 38.0 = 881 R-21 Wall .(W.21.2x6.16) (IM 348.0 X 0.0690 X 55.0 = 1,321 X X = X X X X = X X = X X = Page Total 3,925 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (N) 0.0 X 45.2 + 4.0 X 204.4 = 818 Window (W) 0.0 X 33.4 + 30.0 X 101.6 = 3,049 Window 0.0 X 33.4 + 48.0 X 101.6 = 4,879 X + X = X + X = X + X = X + X = X + X = X + X = Page Total 8,745 Internal Gain Btu/hr -Occu ants 3.0 Occupants X 230 Btuh/occ. = 690 Equipment 1.0 Dwelling Unit X 1,200 Btu = 1,200 Infiltration: 1.064 X 0.94 X 44.10 X 42 = 1,844 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,404 Latent Gain Btu/hr Occupants 3.0 Occupants X L 200 Btuh/occ. = 600 Infiltration: 4,771 X 0.94 X 44.10 X 0.00523 = 1,030 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,630 EnemvPro 5.1 by EnerovSoft User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 25 of 29 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 12/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Family Great Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 2,354.0 rt' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Ooaoue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (S) I err Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = Z338.0 0.0260 56.0 482.0 0.0690 23.0 102.0 0.0690 29.0 196.0 0.0690 33.0 414.0 0.0690 26.0 24.01 0.5000 26.0 490.0 0.0690 33.0 102.0 0.06901 30.2 24.0 27.8 0.0 27.7 6.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded I Fpnpctratinn Skylight Window Window Window Window Window Window Window Window nripntatinn (N) (N) (N) (N) (NE) (S) (S) (S) (S) 3,404 765 204 446 743 312 1,116 213 1 7,2031 Area X X X X X X X X X GLF + + + + + + + + + Area X X X. X X X X X X GLF = = = = = = = = = 0.0 36.7 16.0 127.4 0.0 27.7 120.0 27.7 0.0 27.7 120.0 27.7 0.0 27.7 36.0 27.7 0.0 27.7 80.0 42.5 0.0 27.7 24.0 27.8 0.0 27.7 6.0 27.8 0.0 27.7 60.0 27.8 0.0 1 27.7 80.0 27.8 Page Total Btu/hr 2,038 3,320 3,320 996 3,397 667 167 1,667 2,222 17, 794 d Gain nts 3.0 Occupants X 230 Btuh/occ. Btu/hr ent 1.0 Dwelling Unit X 1,600 Btu 1.1 (Infiltration: 1.064 X 0.94 X 128.81 X 42 Air Sensible CFM ELA 6T I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,0681 Latent Gain Btu/hr Occupants 3.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,771 X 0.94 X 128.81 X 0.00523 = 3,008 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 12/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Family Great Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 2,354.0 /t' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X. X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (NIM 0.0 X 27.7 + 80.0 X 42.5 = 3,397 X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 3,397 Internal Gain Btu/hr— tu/hrOccu ants 3.0 Occupants X 230 Occupants Btuh/occ. = 690 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 128.81 X 42 = 5,384 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,068 Latent Gain Btu/hr Occupants 3.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,771 X 0.94 X 128.81 X 0.00523 = 3,008 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,608 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-12-04714:08:24 ID: Page 27 of 29 C] • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 12/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,408.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 1,404.0 X 0.0260 X 77.0 = 2,811 R-21 Wall (W.21.2x6.16) (N) 140.0 X 0.0690 X 31.0 = 299 R-21 Wall (W.21.2x6.16) (E) 608.0 X 0.0690 X 44.0 = 1,846 R-21 Wall (W.21.2x6.16) (S) 88.0 X 0.0690 X 38.0 = 231 X X = X X = X X = X X = X X = Page Total 5,187 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (N) 0.0 X 45.2 + 4.0 X 204.4 = 818 Window (N) 0.0 X 33.4 + 120.0 X 33.4 = 4,003 Window (N)• 0.0 X 33.4 + 4.0 X 33.4 = 133 Window (E) 0.0 X 33.4 + 4.0 X 74.3 = 297 Window (E) 0.0 X 33.4 + 4.0 X 74.3 = 297 X + X = X + X = X + X = X 1 +1 X = Page Total 5,549 Internal Gain Btu/hr Occupants 3.0 Occupants X 2301 Btuh/occ. =1 E690 Equipment 1.0 Dwelling Unit X 1,200 Btu = 1,200 Infiltration: 1.064 X 0.94 X 77.05 X 42 = 3,221 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,846 Latent Gain Btu/hr Occupants 3.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,771 X 0.94 X 77.05 X 0.00523 = 1,799 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,399 EnemvPro 5.1 by EnemySoft User Number., 6712 RunCode: 2012-12-04714:08:24 ID: Pa a 28 of 29 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr & Mrs Richard Albers 1 12/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 432.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 432.0 X 0.0260 X 56.0 = 629 R-21 Wall (W.21.2x6.16) (E) 236.0 X 0.0690 X 33.0 = 537 R-21 Wall '(W.21.2x6.16) (S) 100.0 X 0.0690 X 26.0 = 179 R-21 Wall (W.21.2x6.16) (S K9 92.0 X 0.0690 X 31.0 = 197 R-21 Wall (W.21.2x6.16) (K9 110.0 X 0.0690 X 33.0 . = 250 X X = X X = X X = X X = Page Total 1, 793 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation. Area GLF Area GLF Btu/hr Window (E) 0.0 •X 27.7 + 4:0 X 55.0 = 220 Window (SK9 0.0 X 27.7 + 68.0 X 38.3 = 2,602 Window (W) 0.0 X 27.7 + 50.0 X 55.0 = 2,749 X + X X + X = X + X = X + X = X + X = X + X = Page Total 5,570 Internal Gain Btu/hr Occupants 3.0 Occupants X 230 Btuh/occ. = 690 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 23.64 X 42 = 988 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,642 Latent Gain Btu/hr Occupants 3.0 Occupants • X 200 Btuh/occ. _. 600 Infiltration: 4,771 X 0.94 X 23.64 X 0.00523 = 552 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,152 EnemvPro 5.1 by EnerovSoft User Number: 6712 Runcode: 2012-12-04T14:08.24 ID: Page 29 of 29