Loading...
Appendix F Downtown Drainage StudyAppendix F — Downtown Area Drainage Study for the City of La Quinta La Quinta Village Build -out Plan EIR City of La Quinta DOWNTOWN AREA DRAINAGE STUDY FOR CITY OF LA QUINTA COUNTY OF RIVERSIDE, CALIFORNIA PREPARED BY: P S 0 M A S Date: 01/04/2008 TABLE OF CONTENTS • GENERAL DISCUSSION a. Introduction b. Study Area Location c. Hydrologic Methodology • HYDROLOGIC CONDITIONS a. Existing Conditions b. Existing Site Drainage c. Hydrology Summary Table • RECOMMENDATIONS • HYDROLOGIC AND HYDRAULIC CALCULATIONS a. Off-site Runoff Hydrologic Calculations b. Study Area Runoff Hydrologic Calculations c. Streets and Catch Basin Capacities d. Reinforced Concrete Boxes Capacities • HYDROLOGY MAP a. Downtown Drainage Study Hydrology Map M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doe GENERAL DISCUSSION a. INTRODUCTION The downtown area of the City of La Quinta between Avenida Bermudas and Desert Club Drive and between Calle Tampico and Avenue 52 has generally been developed without requiring drainage detention on-site due to the commercial nature of the development and limited space. This study evaluates this situation to determine if this practice has resulted in adverse impacts in the area or downstream. b. STUDY AREA LOCATION The study area is approximately 25.6 acres and, as mentioned above, is bounded on the east by Desert Club Drive, on the west by Avenida Bermudas, on the north by Calle Tampico, and on the south by Avenue 52. See the Study Area Location Map below: M%roroir' rrm o Y Svnnrs Virtual Earth— Sbgab�nhMe.. goqeonnh Dr .F Ls Quinta jos Nbaes ❑r �p Sports o y Complex Avaruo 50 Calls- F4-.Awnua 57 Avenue 50 4. e rrk+r-arc n Ave `uQ . . y ;P n�� f..a Owma Resorl anC Club �r %"°°vi a a r l + � ule A wecm:gerx c a 4uirsta � cyle ranlplm Cat Ta'nplW j ►krr i tiy� AvuNde fa Fa1CW a kvc voa uvl:exuma wmma w fonax s g 9 ;alln HNAI��� R y _ _,ML6 - - 06A� I> I; Y 4� 4 Cale Smlm Frio s sums m community c Park Iln rJurSnga � C -�. a 4 s TladlWon Gall Club e'a G911R $e[vra � p S isi s e �T�n 4 V @20031.GcrvsvflCerp. p° Study Area Location Map N.T.S. M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doe c. HYDROLOGIC METHODOLOGY The Rational Method, as described in the Riverside County Hydrology Manual, was used to calculate the existing peak flows from a 10 -year storm frequency. The hydrology calculations were conducted through the use of "CivilDesign" hydrology computer program by CivilDesign Corporation. The hydrology calculations are based on Soil Group A (Sandy Loam / Loamy Sand). The selection of the soil type is based on Percolation Testing Technical Memorandum from GeoPentech (September 22, 2004) included in the Master Drainage Plan as Appendix E. Also, in order to take into account the effect of existing dry wells and sand filters within the study area, an impervious percentage of 65% is used in the CivilDesign program. The attached hydrology map depicts the accumulated runoff for the total drainage area flowing to the Calle Tampico drainage system. HYDROLOGIC CONDITIONS a. EXISTING CONDITIONS The study area is approximately 25.6 acres with a 10 -year frequency storm runoff of 41.5 cfs. An off-site drainage area of 48.5 acres, located westerly and basically upstream of the study area, is contributing to the drainage area with a 10 -year frequency storm runoff of 70.9 cfs. The study area is mainly occupied by commercial buildings. Ground surface cover consists of existing asphalt concrete pavements and some landscaping. The delineation of the drainage areas is shown in Downtown Drainage Study Hydrology Map presented in this report. b. EXISTING SITE DRAINAGE This study analyzes these two major drainage areas that drain by sheet flow then street flow towards the north and east and discharge into Calle Tampico. The first area is the off-site area west of the downtown area. This area drains to Avenida Navarro and Avenida Bermudas towards the north and discharges into Calle Tampico. The off-site area consists of residential development, commercial areas and La Quinta Village Park. The drainage system does not include catch basins or pipes. Dry wells and local retention areas exist in the park. It is assumed that the runoff water drains to those dry wells then infiltrates into the soil. The second major area is the downtown area that drains towards Desert Club Drive, then drains towards the north and discharges into Calle Tampico. The downtown area consists of commercial sites (retail) and some residential development. The drainage in this area is mostly sheet flow into local dry wells, sand filters and retention basins, then street flows towards Desert Club Drive. The street drainage system does not include catch basins in this area. The runoff from the area west of downtown is intercepted by a 7 -ft catch basin located along Calle Tampico, between Avenida Bermudas and Desert Club Drive. This catch basin conveys M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doe the runoff to a 2'H x 6'W double reinforced concrete box that drains from west to east along Calle Tampico. However, the catch basin capacity collects only 26.5-cfs from the 71-cfs (10 -yr storm flow) generated from the off-site area. The remaining flow ponds to a depth of 7 -inches, then flows towards the east and joins the 41.5-cfs runoff from the subject site. The combined runoff flows east to another catch basin located along Calle Tampico east of Desert Club Drive. Hydrologic and hydraulic calculations for streets, catch basins and reinforced concrete boxes are presented in the Hydrologic and Hydraulic Calculations section of this report. An existing Coachella Valley Water District (CVWD) 60" RCP storm drain flows north along Desert Club Drive. The 60" RCP conveys overflow runoff from the Crystal Canyon Detention Basins located south of the study area. The 60" RCP drains from south to north and discharges into the La Quinta Evacuation Channel. Also, a 66" RCP exists along Avenue 52 south of the study area. The 66" RCP drains from west to east and conveys a small portion of its flow into the 60" CVWD RCP in Desert Club Drive via an 18" lateral pipe connection. M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doe c. HYDROLOGY SUMMARY TABLE AREA Acreage Q10 cfs A-1 3.6 7.23 A-2 3.8 6.87 A-3 3.8 6.36 A-4 3.8 6.06 A-5 2.5 3.76 A-6 1.8 2.45 A-7 2.2 4.03 A-8 2.2 2.65 A-9 3.6 6.78 A-10 5.4 8.76 A-11 6.7 6.85 A-12 2.2 3.15 A-13 2 2.66 A-14 1 1.99 A-15 0.8 1.23 A-16 2.1 2.64 A-17 1 1.18 TOTAL 48.5 70.97 B-1 4 8 B-2 5.1 9.1 B-3 3.1 5.2 B-4 5.4 8.22 B-5 4 5.67 B-6 4 5.29 TOTAL 25.6 41.48 M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc RECOMMENDATIONS Based on existing studies and the hydrologic studies presented in the Hydrologic Calculations section of this report, the downtown study area is subject to flooding in the northern reaches of Avenida Bermudas, Desert Club Drive and all along Calle Tampico. The capacity of the existing catch basins and 2'H x 6'W DBL. RCB are not enough to convey the 10 -year peak storm runoff from the downtown area and adjacent neighborhood. Therefore, at a minimum, bio -retention, dry wells, sand filters and retention basins are recommended for the proposed and future development within the downtown area to reduce the runoff generated -similar to the existing facilities in the developed sites in the downtown area. Also, it is recommended that some catch basins be constructed upstream (south) of the following intersections, with connections to either dry wells or the RCB storm drain: The roundabout at Avenida Navarro and Avenida Montezuma, Avenida Navarro and Calle Tampico, and Avenida Bermudas and Calle Tampico. The locations of the recommended catch basins and dry wells/sand filters are shown on the Downtown Drainage Study Hydrology Map. As an alternative to completely eliminate this localized flooding potential, a Preliminary Design Report could be prepared to determine if a storm drain connection could be made from just upstream of the existing 2'H x 6'W DBL. RCB in Calle Tampico across Calle Tampico connecting to the existing storm drain running north adjacent to Avenida Bermudas that drains into an existing retention basin. It may be that there are existing utility conflicts that prohibit this connection but this should be investigated to determine if a connection can be made, hydraulically, which could divert some of the flow to the retention basin. M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doe HYDROLOGIC AND HYDRAULIC CALCULATIONS M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc a. OFF-SITE RUNOFF HYDROLOGIC CALCULATIONS M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc Riverside County Rational Hydrology Program CIVILCADD/CIVILDESIGN Engineering Software,(c) 1989 - 2005 Version 7.1 Rational Hydrology Study Date: 12/13/07 File:LAQ10YR.out ---------------------------------------------------------------------- ********* Hydrology Study Control Information ********** English (in -lb) Units used in input data file ---------------------------------------------------------------------- Offsite Area, 10 -yr Storm Program License Serial Number 6124 ---------------------------------------------------------------------- Rational Method Hydrology Program based on Riverside County Flood Control & Water Conservation District 1978 hydrology manual Storm event (year) = 10.00 Antecedent Moisture Condition = 2 2 year, 1 hour precipitation = 0.700(In.) 100 year, 1 hour precipitation = 1.600(In.) Storm event year = 10.0 Calculated rainfall intensity data: 1 hour intensity = 1.070(In/Hr) Slope of intensity duration curve = 0.5900 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 2.000 to Point/Station 4.000 **** INITIAL AREA EVALUATION **** Initial area flow distance = 630.000(Ft.) Top (of initial area) elevation = 61.000(Ft.) Bottom (of initial area) elevation = 55.000(Ft.) Difference in elevation = 6.000(Ft.) Slope = 0.00952 s(percent)= 0.95 TC = k(0.370)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration = 12.364 min. Rainfall intensity = 2.718(In/Hr) for a 10.0 year storm CONDOMINIUM subarea type Runoff Coefficient = 0.739 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Initial subarea runoff = 7.233(CFS) Total initial stream area = 3.600(Ac.) Pervious area fraction = 0.350 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4.000 to Point/Station 6.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 55.000(Ft.) End of street segment elevation = 54.000(Ft.) Length of street segment = 250.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 16.000(Ft.) Distance from crown to crossfall grade break = 14. Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.447(Ft.), Average velocity = 1 Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 16.000(Ft.) Flow velocity = 1.92(Ft/s) Travel time = 2.17 min. TC = 14.53 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.732 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction Rainfall intensity = 2.471(In/Hr) for a 10.0 Subarea runoff = 6.870(CFS) for 3.800(Ac.) Total runoff = 14.103(CFS) Total area = Street flow at end of street = 14.103(CFS) Half street flow at end of street = 7.052(CFS) Depth of flow = 0.478(Ft.), Average velocity = 2 Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 16.000(Ft.) 000 (Ft 10.765(CFS) 923(Ft/s) = 0.650 year storm 7.400(Ac.) 141(Ft/s) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 6.000 to Point/Station 8.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 54.000(Ft.) End of street segment elevation = 53.000(Ft.) Length of street segment = 250.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 16.000(Ft. Distance from crown to crossfall grade break = 14.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.508(Ft.), Average velocity = 2 Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 16.000(Ft.) Flow velocity = 2.30(Ft/s) Travel time = 1.81 min. TC = 16.34 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.726 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction Rainfall intensity = 2.306(In/Hr) for a 10.0 Subarea runoff = 6.363(CFS) for 3.800(Ac.) Total runoff = 20.467(CFS) Total area = Street flow at end of street = 20.467(CFS) Half street flow at end of street = 10.233(CFS) Depth of flow = 0.539(Ft.), Average velocity = 2 Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Flow width (from curb towards crown)= 16.000(Ft.) 17.340(CFS) 303(Ft/s) 0.38 (Ft.) = 0.650 year storm 11.200(Ac.) 374(Ft/s) 1.97(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 8.000 to Point/Station 10.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 53.000(Ft.) End of street segment elevation = 51.000(Ft.) Length of street segment = 250.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 16.000(Ft.) Distance from crown to crossfall grade break = 14.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 23.550(CFS) Depth of flow = 0.500(Ft.), Average velocity = 3.234(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 0.00(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 16.000(Ft.) Flow velocity = 3.23(Ft/s) Travel time = 1.29 min. TC = 17.63 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.723 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 2.205(In/Hr) for a 10.0 year storm Subarea runoff = 6.056(CFS) for 3.800(Ac.) Total runoff = 26.522(CFS) Total area = 15.000(Ac.) Street flow at end of street = 26.522(CFS) Half street flow at end of street = 13.261(CFS) Depth of flow = 0.523(Ft.), Average velocity = 3.303(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 1.13(Ft.) Flow width (from curb towards crown)= 16.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 10.000 to Point/Station 12.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 51.000(Ft.) End of street segment elevation = 50.000(Ft.) Length of street segment = 250.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 16.000(Ft.) Distance from crown to crossfall grade break = 14.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 28.484(CFS) Depth of flow = 0.606(Ft.), Average velocity = 2.536(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 5.30(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 16.000(Ft.) Flow velocity = 2.54(Ft/s) Travel time = 1.64 min. TC = 19.27 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.719 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 2.092(In/Hr) for a 10.0 year storm Subarea runoff = 3.759(CFS) for 2.500(Ac.) Total runoff = 30.281(CFS) Total area = 17.500(Ac.) Street flow at end of street = 30.281(CFS) Half street flow at end of street = 15.140(CFS) Depth of flow = 0.619(Ft.), Average velocity = 2.569(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 5.94(Ft.) Flow width (from curb towards crown)= 16.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 12.000 to Point/Station 14.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 50.000(Ft.) End of street segment elevation = 46.000(Ft.) Length of street segment = 575.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18. Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.571(Ft.), Average velocity = 3 Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 3.00(Ft/s) Travel time = 3.19 min. TC = 22.47 min. Adding area flow to street 000 (Ft 31.588(CFS) 000(Ft/s) 3.55(Ft.) CONDOMINIUM subarea type Runoff Coefficient = 0.712 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 1.911(In/Hr) for a 10.0 year storm Subarea runoff = 2.448(CFS) for 1.800(Ac.) Total runoff = 32.729(CFS) Total area = 19.300(Ac.) Street flow at end of street = 32.729(CFS) Half street flow at end of street = 16.365(CFS) Depth of flow = 0.577(Ft.), Average velocity = 3.029(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 3.84(Ft.) Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 12.000 to Point/Station 14.000 **** CONFLUENCE OF MAIN STREAMS **** The following data inside Main Stream is listed: In Main Stream number: 1 Stream flow area = 19.300(Ac.) Runoff from this stream = 32.729(CFS) Time of concentration = 22.47 min. Rainfall intensity = 1.911(In/Hr) Program is now starting with Main Stream No. 2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 13.000 to Point/Station 14.000 **** INITIAL AREA EVALUATION **** Initial area flow distance = 800.000(Ft.) Top (of initial area) elevation = 51.000(Ft.) Bottom (of initial area) elevation = 45.000(Ft.) Difference in elevation = 6.000(Ft.) Slope = 0.00750 s(percent)= 0.75 TC = k(0.370)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration = 14.270 min. Rainfall intensity = 2.497(In/Hr) for a 10.0 CONDOMINIUM subarea type Runoff Coefficient = 0.733 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction Initial subarea runoff = 4.025(CFS) Total initial stream area = 2.200(Ac.) Pervious area fraction = 0.350 year storm = 0.650 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 13.000 to Point/Station 14.000 **** CONFLUENCE OF MAIN STREAMS **** The following data inside Main Stream is listed: In Main Stream number: 2 Stream flow area = 2.200(Ac.) Runoff from this stream = 4.025(CFS) Time of concentration = 14.27 min. Rainfall intensity = 2.497(In/Hr) Summary of stream data: Stream Flow rate TC No. (CFS) (min) 1 32.729 22.47 2 4.025 14.27 Largest stream flow has longer Qp = 32.729 + sum of Qb Ia/Ib 4.025 * 0.765 = Qp = 35.809 Rainfall Intensity (In/Hr) 1.911 2.497 time of concentration 3.080 Total of 2 main streams to confluence: Flow rates before confluence point: 32.729 4.025 Area of streams before confluence: 19.300 2.200 Results of confluence: Total flow rate = 35.809(CFS) Time of concentration = 22.466 min. Effective stream area after confluence = 21.500(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 14.000 to Point/Station 16.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 45.000(Ft.) End of street segment elevation = 42.000(Ft.) Length of street segment = 725.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.000(Ft Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 37.195(CFS) Depth of flow = 0.647(Ft.), Average velocity = 2.585(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 7.34(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.58(Ft/s) Travel time = 4.67 min. TC = 27.14 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.704 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 1.709(In/Hr) for a 10.0 year storm Subarea runoff = 2.645(CFS) for 2.200(Ac.) Total runoff = 38.454(CFS) Total area = 23.700(Ac.) Street flow at end of street = 38.454(CFS) Half street flow at end of street = 19.227(CFS) Depth of flow = 0.653(Ft.), Average velocity = 2.607(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 7.67(Ft.) Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 14.000 to Point/Station 16.000 **** CONFLUENCE OF MAIN STREAMS **** The following data inside Main Stream is listed: In Main Stream number: 1 Stream flow area = 23.700(Ac.) Runoff from this stream = 38.454(CFS) Time of concentration = 27.14 min. Rainfall intensity = 1.709(In/Hr) Program is now starting with Main Stream No. 2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 32.000 to Point/Station 34.000 **** INITIAL AREA EVALUATION **** Initial area flow distance = 650.000(Ft.) Top (of initial area) elevation = 56.000(Ft.) Bottom (of initial area) elevation = 50.000(Ft.) Difference in elevation = 6.000(Ft.) Slope = 0.00923 s(percent)= 0.92 TC = k(0.370)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration = 12.599 min. Rainfall intensity = 2.688(In/Hr) for a 10.0 year storm CONDOMINIUM subarea type Runoff Coefficient = 0.738 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Initial subarea runoff = 1.985(CFS) Total initial stream area = 1.000(Ac.) Pervious area fraction = 0.350 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.000 to Point/Station 36.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 50.000(Ft.) End of street segment elevation = 45.000(Ft.) Length of street segment = 650.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 2.688(CFS) Depth of flow = 0.280(Ft.), Average velocity = 1.767(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 8.004(Ft.) Flow velocity = 1.77(Ft/s) Travel time = 6.13 min. TC = 18.73 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.720 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 2.127(In/Hr) for a 10.0 year storm Subarea runoff = 1.225(CFS) for 0.800(Ac.) Total runoff = 3.210(CFS) Total area = 1.800(Ac.) Street flow at end of street = 3.210(CFS) Half street flow at end of street = 1.605(CFS) Depth of flow = 0.294(Ft.), Average velocity = 1.837(Ft/s) Flow width (from curb towards crown)= 8.680(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 36.000 to Point/Station 16.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 45.000(Ft.) End of street segment elevation = 42.000(Ft.) Length of street segment = 650.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 4.601(CFS) Depth of flow = 0.347(Ft.), Average velocity = 1.639(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 11.331(Ft.) Flow velocity = 1.64(Ft/s) Travel time = 6.61 min. TC = 25.34 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.707 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 1.780(In/Hr) for a 10.0 year storm Subarea runoff = 2.641(CFS) for 2.100(Ac.) Total runoff = 5.851(CFS) Total area = 3.900(Ac.) Street flow at end of street = 5.851(CFS) Half street flow at end of street = 2.925(CFS) Depth of flow = 0.370(Ft.), Average velocity = 1.734(Ft/s) Flow width (from curb towards crown)= 12.517(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 36.000 to Point/Station 16.000 **** CONFLUENCE OF MAIN STREAMS **** The following data inside Main Stream is listed: In Main Stream number: 2 Stream flow area = 3.900(Ac.) Runoff from this stream = 5.851(CFS) Time of concentration = 25.34 min. Rainfall intensity = 1.780(In/Hr) Program is now starting with Main Stream No. 3 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 20.000 to Point/Station 22.000 **** INITIAL AREA EVALUATION **** Initial area flow distance = 650.000(Ft.) Top (of initial area) elevation = 55.000(Ft.) Bottom (of initial area) elevation = 51.000(Ft.) Difference in elevation = 4.000(Ft.) Slope = 0.00615 s(percent)= 0.62 TC = k(0.370)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration = 13.663 min. Rainfall intensity = 2.562(In/Hr) for a 10.0 year storm CONDOMINIUM subarea type Runoff Coefficient = 0.735 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Initial subarea runoff = 6.776(CFS) Total initial stream area = 3.600(Ac.) Pervious area fraction = 0.350 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 22.000 to Point/Station 26.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 51.000(Ft.) End of street segment elevation = 46.000(Ft.) Length of street segment = 550.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 16.000(Ft.) Distance from crown to crossfall grade break = 14.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 11.246(CFS) Depth of flow = 0.404(Ft.), Average velocity = 2.624(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 14.223(Ft.) Flow velocity = 2.62(Ft/s) Travel time = 3.49 min. TC = 17.16 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.724 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 2.240(In/Hr) for a 10.0 year storm Subarea runoff = 8.759(CFS) for 5.400(Ac.) Total runoff = 15.536(CFS) Total area = 9.000(Ac.) Street flow at end of street = 15.536(CFS) Half street flow at end of street = 7.768(CFS) Depth of flow = 0.443(Ft.), Average velocity = 2.849(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 16.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 24.000 to Point/Station 26.000 **** SUBAREA FLOW ADDITION **** UNDEVELOPED (good cover) subarea Runoff Coefficient = 0.457 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 38.00 Pervious area fraction = 1.000; Impervious fraction = 0.000 Time of concentration = 17.16 min. Rainfall intensity = 2.240(In/Hr) for a 10.0 year storm Subarea runoff = 6.853(CFS) for 6.700(Ac.) Total runoff = 22.389(CFS) Total area = 15.700(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 26.000 to Point/Station 28.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 46.000(Ft.) End of street segment elevation = 43.000(Ft.) Length of street segment = 550.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18. Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.546(Ft.), Average velocity = 2 Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) 000 (Ft 23.958(CFS) 551(Ft/s) 2.31 (Ft.) Flow velocity = 2.55(Ft/s) Travel time = 3.59 min. TC = 20.75 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.715 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction Rainfall intensity = 2.002(In/Hr) for a 10.0 Subarea runoff = 3.152(CFS) for 2.200(Ac.) Total runoff = 25.541(CFS) Total area = Street flow at end of street = 25.541(CFS) Half street flow at end of street = 12.770(CFS) Depth of flow = 0.556(Ft.), Average velocity = 2 Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Flow width (from curb towards crown)= 20.000(Ft.) = 0.650 year storm 17.900(Ac.) 594(Ft/s) 2.81(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 28.000 to Point/Station 16.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 43.000(Ft.) End of street segment elevation = 42.000(Ft.) Length of street segment = 300.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 40.000(Ft.) Distance from crown to crossfall grade break = 38. Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 12.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.616(Ft.), Average velocity = 2 Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 24.822(Ft.) Flow velocity = 2.04(Ft/s) Travel time = 2.45 min. TC = 23.21 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.710 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 000 (Ft 26.968(CFS) 037(Ft/s) 5.82(Ft.) Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 1.875(In/Hr) for a 10.0 year storm Subarea runoff = 2.664(CFS) for 2.000(Ac.) Total runoff = 28.204(CFS) Total area = 19.900(Ac.) Street flow at end of street = 28.204(CFS) Half street flow at end of street = 14.102(CFS) Depth of flow = 0.625(Ft.), Average velocity = 2.052(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 6.23(Ft.) Flow width (from curb towards crown)= 25.226(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 28.000 to Point/Station 16.000 **** CONFLUENCE OF MAIN STREAMS **** The following data inside Main Stream is listed: In Main Stream number: 3 Stream flow area = 19.900(Ac.) Runoff from this stream = 28.204(CFS) Time of concentration = 23.21 min. Rainfall intensity = 1.875(In/Hr) Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 38.454 27.14 1.709 2 5.851 25.34 1.780 3 28.204 23.21 1.875 Largest stream flow has longer time of concentration Qp = 38.454 + sum of Qb Ia/Ib 5.851 * 0.960 = 5.618 Qb Ia/Ib 28.204 * 0.912 = 25.714 Qp = 69.787 Total of 3 main streams to confluence: Flow rates before confluence point: 38.454 5.851 28.204 Area of streams before confluence: 23.700 3.900 19.900 Results of confluence: Total flow rate = 69.787(CFS) Time of concentration = 27.140 min. Effective stream area after confluence = 47.500(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 16.000 to Point/Station 38.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 42.000(Ft.) End of street segment elevation = 40.000(Ft.) Length of street segment = 200.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 40.000(Ft.) Distance from crown to crossfall grade break = 38.000(Ft Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 12.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.693(Ft.), Average velocity = 3. Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 28.634(Ft.) Flow velocity = 3.81(Ft/s) Travel time = 0.88 min. TC = 28.02 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.702 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction Rainfall intensity = 1.677(In/Hr) for a 10.0 Subarea runoff = 1.178(CFS) for 1.000(Ac.) Total runoff = 70.965(CFS) Total area = Street flow at end of street = 70.965(CFS) Half street flow at end of street = 35.482(CFS) Depth of flow = 0.694(Ft.), Average velocity = 3. Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Flow width (from curb towards crown)= 28.704(Ft.) End of computations, total study area = 48. The following figures may be used for a unit hydrograph study of the same area. Area averaged pervious area fraction(Ap) = 0.440 Area averaged RI index number = 32.8 70.449(CFS) 809(Ft/s) 9.63(Ft.) = 0.650 year storm 48.500(Ac.) 815(Ft/s) 9.70(Ft.) 50 (Ac.) b. STUDY AREA RUNOFF HYDROLOGIC CALCULATIONS M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc Riverside County Rational Hydrology Program CIVILCADD/CIVILDESIGN Engineering Software,(c) 1989 - 2005 Version 7.1 Rational Hydrology Study Date: 12/13/07 File:lagl0yr.out ---------------------------------------------------------------------- ********* Hydrology Study Control Information ********** English (in -lb) Units used in input data file ---------------------------------------------------------------------- Study Area -Downtown, 10 -yr Storm Program License Serial Number 6124 ---------------------------------------------------------------------- Rational Method Hydrology Program based on Riverside County Flood Control & Water Conservation District 1978 hydrology manual Storm event (year) = 10.00 Antecedent Moisture Condition = 2 2 year, 1 hour precipitation = 0.700(In.) 100 year, 1 hour precipitation = 1.600(In.) Storm event year = 10.0 Calculated rainfall intensity data: 1 hour intensity = 1.070(In/Hr) Slope of intensity duration curve = 0.5900 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 50.000 to Point/Station 52.000 **** INITIAL AREA EVALUATION **** Initial area flow distance = 600.000(Ft.) Top (of initial area) elevation = 56.000(Ft.) Bottom (of initial area) elevation = 51.000(Ft.) Difference in elevation = 5.000(Ft.) Slope = 0.00833 s(percent)= 0.83 TC = k(0.370)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration = 12.454 min. Rainfall intensity = 2.706(In/Hr) for a 10.0 year storm CONDOMINIUM subarea type Runoff Coefficient = 0.739 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Initial subarea runoff = 7.999(CFS) Total initial stream area = 4.000(Ac.) Pervious area fraction = 0.350 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 52.000 to Point/Station 54.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 51.000(Ft.) End of street segment elevation = 47.000(Ft.) Length of street segment = 400.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 16.000(Ft.) Distance from crown to crossfall grade break = 14. Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.412(Ft.), Average velocity = 2 Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 14.613(Ft.) Flow velocity = 2.80(Ft/s) Travel time = 2.38 min. TC = 14.84 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.731 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction Rainfall intensity = 2.441(In/Hr) for a 10.0 Subarea runoff = 9.096(CFS) for 5.100(Ac.) Total runoff = 17.095(CFS) Total area = Street flow at end of street = 17.095(CFS) Half street flow at end of street = 8.547(CFS) Depth of flow = 0.448(Ft.), Average velocity = 3 Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 16.000(Ft.) 000 (Ft 12.617(CFS) 797(Ft/s) = 0.650 year storm 9.100(Ac.) 046(Ft/s) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 54.000 to Point/Station 56.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 47.000(Ft.) End of street segment elevation = 45.000(Ft.) Length of street segment = 250.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.000(Ft Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.485(Ft.), Average velocity = 2 Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 18.245(Ft.) Flow velocity = 2.87(Ft/s) Travel time = 1.45 min. TC = 16.29 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.726 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction Rainfall intensity = 2.310(In/Hr) for a 10.0 Subarea runoff = 5.202(CFS) for 3.100(Ac.) Total runoff = 22.296(CFS) Total area = Street flow at end of street = 22.296(CFS) Half street flow at end of street = 11.148(CFS) 19.773(CFS) 867(Ft/s) = 0.650 year storm 12.200(Ac.) Depth of flow = 0.503(Ft.), Average velocity = 2.941(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 0.16(Ft.) Flow width (from curb towards crown)= 19.159(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 56.000 to Point/Station 58.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 45.000(Ft.) End of street segment elevation = 43.000(Ft.) Length of street segment = 400.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 26.457(CFS) Depth of flow = 0.569(Ft.), Average velocity = 2.536(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 3.45(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.54(Ft/s) Travel time = 2.63 min. TC = 18.92 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.720 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 2.115(In/Hr) for a 10.0 year storm Subarea runoff = 8.217(CFS) for 5.400(Ac.) Total runoff = 30.513(CFS) Total area = 17.600(Ac.) Street flow at end of street = 30.513(CFS) Half street flow at end of street = 15.257(CFS) Depth of flow = 0.593(Ft.), Average velocity = 2.632(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 4.65(Ft.) Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 58.000 to Point/Station 60.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 43.000(Ft.) End of street segment elevation = 42.000(Ft.) Length of street segment = 300.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 33.429(CFS) Depth of flow = 0.647(Ft.), Average velocity = 2.321(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 7.35(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.32(Ft/s) Travel time = 2.15 min. TC = 21.07 Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.715 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious Rainfall intensity = 1.984(In/Hr) for a Subarea runoff = 5.673(CFS) for 4. min. fraction 10.0 000(Ac.) Total runoff = 36.186(CFS) Total area = Street flow at end of street = 36.186(CFS) Half street flow at end of street = 18.093(CFS) Depth of flow = 0.663(Ft.), Average velocity = Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Flow width (from curb towards crown)= 20.000(Ft.) = 0.650 year storm 21.600(Ac.) 2.369(Ft/s) 8.14(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 60.000 to Point/Station 62.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 42.000(Ft.) End of street segment elevation = 40.000(Ft.) Length of street segment = 400.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18. Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.637(Ft.), Average velocity = 2 Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.81(Ft/s) Travel time = 2.38 min. TC = 23.45 min. Adding area flow to street CONDOMINIUM subarea type Runoff Coefficient = 0.710 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 000 (Ft 38.920(CFS) 805(Ft/s) 6.86(Ft.) Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 32.00 Pervious area fraction = 0.350; Impervious fraction = 0.650 Rainfall intensity = 1.863(In/Hr) for a 10.0 year storm Subarea runoff = 5.291(CFS) for 4.000(Ac.) Total runoff = 41.477(CFS) Total area = 25.600(Ac.) Street flow at end of street = 41.477(CFS) Half street flow at end of street = 20.738(CFS) Depth of flow = 0.650(Ft.), Average velocity = 2.852(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 7.48(Ft.) Flow width (from curb towards crown)= 20.000(Ft.) End of computations, total study area = 25.60 (Ac.) The following figures may be used for a unit hydrograph study of the same area. Area averaged pervious area fraction(Ap) = 0.350 Area averaged RI index number = 32.0 c. STREETS AND CATCH BASIN CAPACITIES M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc AVENIDA BERMUDAS CAPACITY M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc CIVILCADD/CIVILDESIGN Engineering Software, (c) 2004 Version 7.0 -------------------------------------------------------------------- Program License Serial Number 6124 *** Street Flow Analysis *** AVENIDA BERMUDAS Upstream (headworks) Elevation = 0.710(Ft.) Downstream (outlet) Elevation = 0.000(Ft.) Runoff/Flow Distance = 100.000(Ft.) Maximum flow rate in channel(s) = 44.400(CFS) -------------------------------------------------------------------- Top of street segment elevation = 0.710(Ft.) End of street segment elevation = 0.000(Ft.) Length of street segment = 100.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 20.000(Ft Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 12.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Half street cross section data points: X-coordinate (Ft.) Y-coordinate (Ft.) 0.0000 0.7400 right of way 12.0000 0.5000 top of curb 12.0000 0.0000 flow line 14.0000 0.1600 gutter end 24.0000 0.3600 grade break 44.0000 0.7600 crown Depth of flow = 0.638(Ft.) Average velocity = 3.036(Ft/s) Total flow rate in 1/2 street = 22.200(CFS) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 6.91(Ft.) Streetflow hydraulics: Halfstreet flow width (curb to crown) = 25.912(Ft.) Average flow velocity = 3.04(Ft/s) Channel including Gutter and area towards property line: Flow Width = 8.912(Ft.) Flow Area = 1.594(Sq.Ft) Velocity = 2.275(Ft/s) Flow Rate = 3.627(CFS) Froude No. = 0.9480 Channel from outside edge of gutter towards grade break: Flow Width = 10.000(Ft.) Flow Area = 3.782(Sq.Ft) Velocity = 3.889(Ft/s) Flow Rate = 14.709(CFS) Froude No. = 1.1143 Channel from grade break to crown: Flow Width = 13.912(Ft.) Flow Area = 1.935(Sq.Ft) Velocity = 1.996(Ft/s) Flow Rate = 3.864(CFS) Froude No. = 0.9432 Total flow rate in street = 44.400(CFS) DESERT CLUB DRIVE CAPACITY M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc CIVILCADD/CIVILDESIGN Engineering Software, (c) 2004 Version 7.0 -------------------------------------------------------------------- Program License Serial Number 6124 ------------------------------------------------------------------ *** Street Flow Analysis *** DESERT CLUB DRIVE Upstream (headworks) Elevation = 0.500(Ft.) Downstream (outlet) Elevation = 0.000(Ft.) Runoff/Flow Distance = 100.000(Ft.) Maximum flow rate in channel(s) = 41.500(CFS) ------------------------------------------------------------------ Top of street segment elevation = 0.500(Ft.) End of street segment elevation = 0.000(Ft.) Length of street segment = 100.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 12.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 12.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Half street cross section data points: X-coordinate (Ft.) Y-coordinate (Ft.) 0.0000 0.7400 right of way 12.0000 0.5000 top of curb 12.0000 0.0000 flow line 14.0000 0.1600 gutter end 20.0000 0.2800 grade break 32.0000 0.5200 crown Depth of flow = 0.650(Ft.) Average velocity = 2.852(Ft/s) Total flow rate in 1/2 street = 20.750(CFS) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 7.49(Ft.) Streetflow hydraulics: Halfstreet flow width (curb to crown) = 20.000(Ft.) Average flow velocity = 2.85(Ft/s) Channel including Gutter and area towards property line: Flow Width = 9.486(Ft.) Flow Area = 1.700(Sq.Ft) Velocity = 2.004(Ft/s) Flow Rate = 3.407(CFS) Froude No. = 0.8345 Channel from outside edge of gutter towards grade break: Flow Width = 6.000(Ft.) Flow Area = 2.578(Sq.Ft) Velocity = 3.718(Ft/s) Flow Rate = 9.585(CFS) Froude No. = 0.9994 Channel from grade break to crown: Flow Width = 12.000(Ft.) Flow Area = 2.997(Sq.Ft) Velocity = 2.589(Ft/s) Flow Rate = 7.758(CFS) Froude No. = 0.9130 Total flow rate in street = 41.500(CFS) CALLE TAMPICO AND CATCH BASIN CAPACITIES M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc CIVILCADD/CIVILDESIGN Engineering Software, (c) 2004 Version 7.0 -------------------------------------------------------------------- Program License Serial Number 6124 ------------------------------------------------------------------ *** Street Flow +Inlet Analysis *** CALLE TAMPICO Upstream (headworks) Elevation = 0.120(Ft.) Downstream (outlet) Elevation = 0.000(Ft.) Runoff/Flow Distance = 100.000(Ft.) Maximum flow rate in channel(s) = 71.000(CFS) -------------------------------------------------------------------- Top of street segment elevation = 0.120(Ft.) End of street segment elevation = 0.000(Ft.) Length of street segment = 100.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 40.000(Ft.) Distance from crown to crossfall grade break = 38.000(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side(s) of the street Distance from curb to property line = 12.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 2.000(Ft.) Gutter hike from flowline = 1.920(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Half street cross section data points: X-coordinate (Ft.) Y-coordinate (Ft.) 0.0000 0.7400 right of way 12.0000 0.5000 top of curb 12.0000 0.0000 flow line 14.0000 0.1600 gutter end 14.0000 0.1600 grade break 52.0000 0.9200 crown CURB INLET TYPE STREET DRAIN, Opening Height = 8.000(In.) Street Inlet Calculations: Street flow in street inlet depression = 71.000(CFS) Gutter depression depth = 4.000(In.) Gutter depression width = 2.000(Ft.) Depth of flow = 1.447(Ft.) Average velocity = 2.357(Ft/s) Total flow rate in 1/2 street = 71.000(CFS) !!Warning: Water is above left or right bank elevations U.S. DOT Hydraulic Engineering Circular No. 12 inlet calculations: Street flow half width at start of inlet = 40.000(Ft.) Flow rate in gutter section of street = Qw = 19.376(CFS) Given inlet length L = 7.000(Ft.) Ratio of frontal flow to total flow = EO = 0.2729 Street slope is less than 0.5% , Depth of flow indicates an orifice flow condition exists for an opening height of 8.00(In.) Using equation Qi = .67hL(2gd0)^.5 Maximum inlet flow capacity = 26.478(CFS) Half street cross section data points through curb inlet: X-coordinate (Ft.) Y-coordinate (Ft.) 0.0000 1.0733 right of way 12.0000 0.8333 top of curb 12.0000 0.0000 flow line 14.0000 0.4933 gutter/depression end 14.0000 0.4933 grade break 52.0000 1.2533 crown Remaining flow in street below inlets = 44.522(CFS) Depth of flow = 0.977(Ft.) Average velocity = 1.962(Ft/s) Total flow rate in 1/2 street = 44.522(CFS) !!Warning: Water is above left or right bank elevations Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 23.86(Ft.) Streetflow hydraulics: Halfstreet flow width (curb to crown) = 40.000(Ft.) Average flow velocity = 1.96(Ft/s) Channel including Gutter and area towards property line: Flow Width = 14.000(Ft.) Flow Area = 6.081(Sq.Ft) Velocity = 1.922(Ft/s) Flow Rate = 11.686(CFS) Froude No. = 0.5138 Channel from outside edge of gutter towards grade break: Flow Width = 0.000(Ft.) Flow Area = 0.000(Sq.Ft) Velocity = 0.000(Ft/s) Flow Rate = 0.000(CFS) Froude No. = 0.0000 Channel from grade break to crown: Flow Width = 38.000(Ft.) Flow Area = 16.615(Sq.Ft) Velocity = 1.976(Ft/s) Flow Rate = 32.836(CFS) Froude No. = 0.5267 Total flow rate in street = 44.522(CFS) d. REINFORCED CONCRETE BOXES AND PIPES CAPACITIES M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc 00 N O O O r N O Co LO 0 Q J C0 z O zQ J Q � C U 0 J E U O O U) J LL W i m D Cl) OLO O U O O O O U Q J O p O O U O O O O M C0 � N O O O O O LL O O O O O O O O 00 V O _ CL J U n CCC - CC90 U r O M O Cl) O N � U M O O r— Lf? (.0O M Ln M Ln O r— � O O r CD O O O O N C) O co L.C) N M M CO O Cp Q w �: � w a oc c� v = Z a I - �1-1 cc - �- _ � N � a w �_ V) LLJ Z W d a _ W = O Q �� a p Q OC p W Q CO o W Q W �a U Q o y �- 2 a? - Z Q o p Q) Z a �- W �- >. �- W C7 a I- w z a o Q w o o a �- o N Q Q LLI z _ J y O W W a J U_ W O W W W W a m a aa a O Cf) HYDROLOGY MAP M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc a. DOWNTOWN DRAINAGE STUDY HYDROLOGY MAP M:\1LAQ010102\ENGR\DESIGN\HYDR\Drainage Study Report.doc