Loading...
BCOM2020-0011ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 2/18/2020 2/18/2020 EMAIL TO INTERWEST REGARDING DIGITAL SUBMITTAL E-MAIL JAKE FUSON 3/12/2020 3/12/2020 NOTIFIED APPLICANT OF 1ST REVIEW CORRECTIONS. E-MAIL JAKE FUSON 4/16/2020 4/16/2020 NOTIFIED APPLICANT OF 2ND REVIEW CORRECTIONS. E-MAIL JAKE FUSON 5/4/2020 5/4/2020 NOTIFIED APPLICANT OF PLAN APPROVAL AND CONDITIONS FOR ISSUANCE. E-MAIL JAKE FUSON 9/15/2020 9/15/2020 NOTIFIED APPLICANT THAT REVISION 1 PLANS ARE APPROVED AND FEE IS READY FOR PAYMENT. E-MAIL JAKE FUSON 9/25/2020 9/25/2020 CERTIFICATE OF ACCEPTANCE FORM RECEIVED VIA EMAIL, NOTIFIED CONTRACTOR THAT (3) ADDITIONAL CLOSEOUT ENERGY FORMS WERE STILL REQUIRED. Description: LA QUINTA NAIL BAR / 2,368SF NAIL SALON TENANT IMPROVEMENT Type: BUILDING COMMERCIAL (WEB) Subtype: REMODEL Status: FINALED Applied: 2/14/2020 AHI Parcel No: 600390029 Site Address: 79070 HIGHWAY 111 STE 103 LA QUINTA,CA 92253 Approved: 5/4/2020 JFU Subdivision: PM 29351 Block: Lot: 11 Issued: 5/7/2020 Online Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 9/21/2021 AOR Valuation: $50,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: LA QUINTA NAIL BAR / 2,368 SF NAIL SALON TENANT IMPROVEMENT [VB/B-OCC/24-OL/SPRINKLED]. THIS PERMIT DOES NOT INCLUDE ALTERATIONS TO FIRE-RESISTANCE RATED CONSTRUCTION, BUILDING SIGNAGE OR HVAC EQUIPMENT REPLACEMENT. NO PATH OF TRAVEL UPGRADES REQUIRED PER ARCHITECT OF RECORD. TUMF ASSESSMENT NOT TRIGGERED PER 2018 HANDBOOK. 2019 CALIFORNIA BUILDING CODES. REVISION 1 - ELECTRICAL DISTRIBUTION EQUIPMENT REVISION (REVISED SINGLE LINE DIAGRAM, POWER PLAN & PANEL SCHEDULE). Printed: Tuesday, June 18, 2024 11:38:28 AM 1 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 E-MAIL STEPHANIE SWANSTROM 5/6/2020 5/28/2020 Mr. Huynh, I’ve attached the building application and the business license you submitted. You listed Vincent Tran as your contractor. I need the letter from Vincent stating he ’s no longer the contractor. The business license is for the nail salon, we will not issue a business license until your building work is almost complete. Your contractor will need a business license. Mr. Huynh, One more thing. If your contractor does not have worker’s compensation, a sub-list will be required to obtain your permit. Each sub-contractor will need a business license and all the information across the entire line of the form will need to be complete and check before permit issuance. NOTE JACK LIMA 5/7/2020 5/7/2020 ADDED CONTRACTOR FEE TO THIS PERMIT UNDER ADMINISTRATIVE 'CHANGE OF CONTRACTOR ACCOUNT'. ONCE THE PERMIT FEES ARE PAID, I WILL MOVE THE FEES OVER TO BUSINESS LICENSE # 768738. FEES PAID - FUNDS TRANSFERRED PLEASE SEE ATTACHMENTS FOR ORIGINAL RECEIPT. NOTE KOHL HETRICK 3/4/2020 3/4/2020 Need to research. Appears to have added a demising wall to create 2 tenant spaces where there was previously only 1 throughout the addressed building. PENDING DOCUMENTS STEPHANIE SWANSTROM 5/6/2020 5/28/2020 LETTER FROM CONTRACTOR - VINCEN TRAN EXPLAINING HE'S TO BE REMOVED FROM THE JOB NEW CONTRACTOR - MAYBE SUBLIST TOO (EMAILED IT) NEW CONTRACTOR - BUSINESS LICNESE. PUBLIC COUNTER VISIT AARON HICKSON 3/10/2020 3/10/2020 LA QUINTA NAIL BAR BUSINESS LICENSE APPLICATION IN FOLDER FRONT COUNTER WITH BUILDING APPLICATION Printed: Tuesday, June 18, 2024 11:38:28 AM 2 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST JAKE FUSON 2/18/2020 5/7/2020 5/7/2020 COMPLETE COMPLETE -CONTRACTOR NEEDS BUSINESS LICENSE -PROJECT VALUATION REQUIRED -PATH OF TRAVEL FORM REQUIRED (SEE JF WITH QUESTIONS) UPDATE: P.O.T. FORM & VALUATION RECEIVED. CONTRACTOR BUSINESS LICENSE STILL OUTSTANDING. CONTRACTOR BUSINESS LICENSE RECIEVED. TELEPHONE CALL STEPHANIE SWANSTROM 5/5/2020 5/5/2020 SPOKE TO MR. HUYAN, HE STATED HE'LL BE USING A DIFERENT CONTRACTOR. I EXPLAINED HE'LL NEED TO GET A LETTER FROM THE CURRENT CONTRACTOR (VINCENT TRAN) STATING HE WILL NOT BE WORKING ON THE PROJECT. ABOUT 10 MINUTES AFTER WE ENDED THE PHONE CALL, THE CONTRACTOR CALLED ME STATING MR. HUYAN WAS GETTING FRUSTRATED. I EXPLAINED EVERYTHING TO HIM AS WELL. THERE WAS A MESSAGE TO CALL MR. HUYAN, I CALLED AND HAD TO EXPLAIN EVERYTHING AGAIN. HE STATED HE DIDN'T LIST VINCEN TRAN AS THE CONTRACTOR. HE ASKED IF I COULD FIND THE APPLICATION, I FOUND HIS APPLICATION AND BUSINESS LICENSE APPLICATION WHERE HE LISTED VINCEN AS THE CONTRACTOR AND THE BUSINESS LICENSE FOR THE SALON. I EMAILED BOTH TO HIM AND CALLED HIM BACK. HE SEEMED TO UNDERSTAND WE NEED THE LETTER FROM THE CONTRACTOR AND THE NEW CONTRACTOR WOULD NEED A BUINSESS LICNESE. I LATER EMAILD HIM THE SUBLIST AS WELL, AND EXPLAINED IF HIS CONTRACTOR. (SEE EMAIL) CONDITIONS Printed: Tuesday, June 18, 2024 11:38:28 AM 3 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT DUNG HUYNH - APPLICANT 73866 VAN GOGH DR PALM DESERT CA 92211 DUNGTHHUYNH2000@ GMAIL.COM CONTRACTOR MODEL BUILDERS INC 15030 GOLDEN WEST CIR #11612 WESTMINISTER CA 92685 MODEL.BUILDERS@YA HOO.COM CONTRACTOR (HISTORY) 1 CENTRAL PACIFIC DESIGN/BUILD 11061 STRATFORD WAY GARDEN GROVE CA 92840 VINCENT@CENTRALPA CIFIC-DB.COM OWNER INLAND AMERICAN LAQUINTA PAV P O BOX 9271 OAK BROOK IL 92253 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY RE-INSPECTION FEE 101-0000-42400 0 $80.50 $80.50 7/15/20 WEB5701 CREDIT MODEL BUILDERS INC ECON RE-INSPECTION FEE 101-0000-42400 0 $80.50 $80.50 7/13/20 WEB5665 CREDIT MODEL BUILDERS INC ECON Total Paid for ADMINISTRATIVE: $161.00 $161.00 HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 10 $104.00 $104.00 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.75 $120.75 $120.75 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 9/15/20 WEB6237 04290G CREDIT MODEL BUILDERS INC ECON HOURLY CHARGE - INTERWEST STRUCTURAL PLAN REVIEW 101-0000-42600 0.5 $62.50 $62.50 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for BLDG CITY STAFF - PER HOUR: $367.75 $367.75 BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $2.00 Printed: Tuesday, June 18, 2024 11:38:28 AM 4 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY NON-RESIDENTIAL, EA ADDITIONAL 2,000SF 101-0000-42403 0 $40.25 $40.25 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON NON-RESIDENTIAL, EA ADDITIONAL 2,000SF PC 101-0000-42600 0 $10.73 $10.73 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON NON-RESIDENTIAL, FIRST 2,000SF 101-0000-42403 0 $120.75 $120.75 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON NON-RESIDENTIAL, FIRST 2,000SF PC 101-0000-42600 0 $93.38 $93.38 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for ELECTRICAL - NEW CONSTRUCTION 2019: $265.11 $265.11 FIRE COMMERCIAL TI 101-0000-42421 0 $161.00 $161.00 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON FIRE COMMERCIAL TI PC 101-0000-42420 0 $242.00 $242.00 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for FIRE FEES: $403.00 $403.00 EXHAUST HOOD 101-0000-42402 0 $13.42 $13.42 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON EXHAUST HOOD PC 101-0000-42600 0 $5.37 $5.37 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $40.25 $40.25 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $40.25 $40.25 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON VENT FAN 101-0000-42402 0 $40.26 $40.26 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON VENT FAN PC 101-0000-42600 0 $16.11 $16.11 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for MECHANICAL 2019: $155.66 $155.66 PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 $125.00 2/14/20 R59644 1015 CHECK LA QUINTA NAIL BAR AHI Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 $125.00 FIXTURE/TRAP 101-0000-42401 0 $308.66 $308.66 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON FIXTURE/TRAP PC 101-0000-42600 0 $308.66 $308.66 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Printed: Tuesday, June 18, 2024 11:38:28 AM 5 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.42 $13.42 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.83 $26.83 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON WATER HEATER/VENT 101-0000-42401 0 $13.42 $13.42 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON WATER HEATER/VENT PC 101-0000-42600 0 $8.05 $8.05 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.42 $13.42 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.42 $13.42 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for PLUMBING 2019: $705.88 $705.88 RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 $21.00 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 101-0000-42600 ($69.76)($69.76)5/4/20 OFFSET OFFSET JFU 101-0000-42600 ($54.74)($54.74)5/4/20 OFFSET OFFSET JFU REMODEL, EA ADDITIONAL 500SF 101-0000-42400 0 $120.75 $120.75 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON REMODEL, EA ADDITIONAL 500SF PC 101-0000-42600 0 $96.60 $96.60 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON REMODEL, FIRST 100SF 101-0000-42400 0 $54.74 $54.74 5/4/20 DEPOSIT DEPOSIT JFU REMODEL, FIRST 100SF PC 101-0000-42600 0 $69.76 $69.76 5/4/20 DEPOSIT DEPOSIT JFU REMODEL, FIRST 100SF PC 101-0000-42600 0 $79.97 $79.97 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for REMODEL 2019: $297.32 $297.32 101-0000-42600 ($0.50)($0.50)5/4/20 OFFSET OFFSET JFU Printed: Tuesday, June 18, 2024 11:38:28 AM 6 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES UNDERGROUND PLBG AOR 5/13/2020 5/13/2020 APPROVED W/EXCEPTIO N eTRAKiT Inspection Request 5/12/2020 2:26 PM MODEL BUILDERS INC Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM ALL AREAS APPROVED WITH EXCEPTION OF THE WASHER REQUIRES STANDPIPE INSTALLATION AND THE BACK ROOM SINKS NEED SEPARATE VENTING BASED ON ABOVE SLAB ROUGH IN PIPING OR SEPARATE DRAIN PIPES. GAS LINE/TEST AOR 6/10/2020 6/10/2020 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY SMI - COMMERCIAL 101-0000-20308 0 $0.50 $0.50 5/4/20 DEPOSIT DEPOSIT JFU Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.00 $0.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 ALTERATIONS/ADDITIO NS - NON-RESIDENTIAL 101-0000-42400 0 $161.00 $161.00 5/7/20 WEB5066 CREDIT MODEL BUILDERS INC ECON Total Paid for ZONING CLEARANCE - PLANNING PLAN CHECK: $161.00 $161.00 TOTALS:$2,669.72 $2,669.72 Printed: Tuesday, June 18, 2024 11:38:28 AM 7 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 ROUGH PLBG AOR 6/10/2020 6/10/2020 APPROVED eTRAKiT Inspection Request 6/9/2020 10:07 AM MODEL BUILDERS INC I would like to make appointment inspection for slab rebar. electrical, plumbing and framing. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM INCLUDES CORRECTION OF UNDERGROUND PLUMBING EXCEPTIONS. ROUGH ELEC AOR 6/10/2020 6/10/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 6/9/2020 10:07 AM MODEL BUILDERS INC I would like to make appointment inspection for slab rebar. electrical, plumbing and framing. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM WALLS ONLY, CEILINGS NOT READY, AND SWITCHING OF LIGHTING IN DAYLIT AREAS NOT CONTROLLED BY MANDATORY MEASURES. FRAMING AOR 6/10/2020 6/10/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 6/9/2020 10:07 AM MODEL BUILDERS INC I would like to make appointment inspection for slab rebar. electrical, plumbing and framing. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM Printed: Tuesday, June 18, 2024 11:38:28 AM 8 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 FRAMING AOR 6/10/2020 6/10/2020 PARTIALLY APPROVED eTRAKiT Inspection Request WALLS INCLUDING DEMISING WALL ONLY, CORRECTIONS REQUIRED AT HARD LID CEILING FRAMING AS IT DOES NOT MATCH APPROVED DETAILING. OVERHEAD ROUGH PIPING KHET 6/23/2020 6/23/2020 APPROVED FRAMING DCL 6/24/2020 6/24/2020 DISAPPROVE D eTRAKiT Inspection Request 6/23/2020 3:43 PM MODEL BUILDERS INC Ceiling framing and drywall Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM - KICKERS MISSING AT 48" ON CENTER PER PERIMETER SOFFIT DETAIL.- INSTALL MECHANICAL REGISTERS AT WAX ROOMS AND COMPLETE RETURN AIR DUCTING.- MAIN AREA SOFFITS NOT PER PLAN. RFI FROM EOR REQUIRED FOR ALTERNATE DIAGONAL AND VERTICAL STUD SPACING AND ATTACHMENT. DRYWALL NAIL DCL 6/24/2020 6/24/2020 NOT READY eTRAKiT Inspection Request 6/23/2020 3:43 PM MODEL BUILDERS INC Ceiling framing and drywall Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM - WALLS INCOMPLETE. CALL IN WHEN READY. Printed: Tuesday, June 18, 2024 11:38:28 AM 9 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 ROUGH MECH JFU 7/2/2020 7/2/2020 APPROVED W/EXCEPTIO N eTRAKiT Inspection Request 6/30/2020 7:53 PM MODEL BUILDERS INC Drop Ceiling framing. and rough mechanical Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM DOES NOT INCLUDE FRAMING--SEE FRAMING COMMENTS. FRAMING JFU 7/2/2020 7/2/2020 DISAPPROVE D eTRAKiT Inspection Request 6/30/2020 7:53 PM MODEL BUILDERS INC Drop Ceiling framing. and rough mechanical Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM SUSPENDED HARD LID CEILING AND SOFFIT FRAMING DO NOT MATCH APPROVED PLANS. RFI'S OR REVISED CONSTRUCTION REQUIRED, REINSPECTION FEE ASSESSED. T-BAR/OVERHEAD JFU 7/2/2020 7/2/2020 APPROVED W/EXCEPTIO N INSPECTED T-BAR/OVERHEAD AT LAUNDRY ROOM. CONSTRUCTION IS APPROVABLE ASIDE FROM THE INSTALLATION OF A COMPRESSION STRUT. CONTRACTOR AGREES TO PULL DOWN CEILING TILES AT A LATER INSPECTION OR THE FINAL INSPECTION TO DEMONSTRATE COMPLIANCE. T-BAR/OVERHEAD JFU 7/14/2020 7/14/2020 APPROVED PREVIOUS COMMENT RESOLVED AT LAUNDRY AREA. Printed: Tuesday, June 18, 2024 11:38:28 AM 10 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 FRAMING JFU 7/14/2020 7/14/2020 DISAPPROVE D eTRAKiT Inspection Request 7/13/2020 9:59 AM MODEL BUILDERS INC Hi, I would like to make appointments ceiling framing and drywall nails inspection. Thank you Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM SAME ISSUES EXIST AT SOFFITS. REINSPECTION FEE ASSESSED. DRYWALL NAIL JFU 7/14/2020 7/14/2020 PARTIALLY APPROVED eTRAKiT Inspection Request 7/13/2020 10:00 AM MODEL BUILDERS INC Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM WAX ROOMS ONLY. FRAMING AOR 7/15/2020 7/15/2020 eTRAKiT Inspection Request 7/14/2020 12:51 PM MODEL BUILDERS INC ceiling kicker frame. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM SAME ISSUES EXIST AT SOFFITS - MET WITH OWNER AND CONTRACTOR ONSITE TO DISCUSS THE RFI REQUIRED FROM THE EOR, BUSINESS CARD GIVEN TO EMAIL REVISED DETAILING. GAS RELEASE AOR 7/16/2020 7/16/2020 APPROVED GAS RELEASE SENT. Printed: Tuesday, June 18, 2024 11:38:28 AM 11 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 FRAMING JFU 7/21/2020 7/21/2020 APPROVED eTRAKiT Inspection Request 7/20/2020 2:54 PM MODEL BUILDERS INC Hi, I would like to make appointment for ceiling framing. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM PREVIOUS CORRECTIONS RESOLVED, OKAY TO APPLY GYPSUM BOARD AT SOFFITS. DRYWALL NAIL JFU 7/27/2020 7/27/2020 APPROVED eTRAKiT Inspection Request 7/23/2020 10:14 PM MODEL BUILDERS INC drywall Nail Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM ALL REMAINING AREAS. TEMP USE OF PERM PWR JFU 7/28/2020 7/28/2020 APPROVED W/EXCEPTIO N eTRAKiT Inspection Request 7/27/2020 3:21 PM MODEL BUILDERS INC Please bring application document for TI owner if he need to pay temporary power fees. Thank you. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM Printed: Tuesday, June 18, 2024 11:38:28 AM 12 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 TEMP USE OF PERM PWR JFU 7/28/2020 7/28/2020 APPROVED W/EXCEPTIO N eTRAKiT Inspection Request DISTRIBUTION EQUIPMENT DOES NOT APPEAR TO MATCH PLANS. PER CONTRACTOR, "PANEL B" HAS BEEN ELIMINATED AND ALL BRANCH CIRCUITRY IS NOW SUPPLIED BY "PANEL A" AND FED BY A SINGLE METER. ELECTRICAL FLOOR PLAN, PANEL SCHEDULES AND SINGLE LINE DIAGRAM MUST BE REVISED PRIOR TO FINAL INSPECTION, HOWEVER THE INSTALLATIONS ARE PROTECTED AND APPEAR TO BE SAFE FOR UTILIZATION, SO A RELEASE WILL BE SENT TO THE UTILITY WITH THE CONDITION THAT THE PLANS GET REVISED AND APPROVED AND A REINSPECTION IS SCHEDULED TO VERIFY COMPLIANCE WITH THE NEW APPROVED PLANS. FINAL**AOR 9/9/2020 9/9/2020 CANCELED eTRAKiT Inspection Request 9/8/2020 12:55 PM MODEL BUILDERS INC Final electrical, plumbing, mechanical and final building. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM T/I FINAL KHET 9/10/2020 9/10/2020 APPROVED REMOTE VIDEO INSPECTION FIRE CLEARANCE GRANTED. MINOR ITEMS TO BE FOLLOWED UP WITH UNDER THE FIRE ANNUAL CASE. FINAL**JFU 9/14/2020 9/14/2020 DISAPPROVE D eTRAKiT Inspection Request 9/10/2020 5:10 PM MODEL BUILDERS INC I would like to make schedule for Final Building inspection. Thank you. Contact Name: MODEL BUILDERS INC Site Address: 79070 HIGHWAY 111 STE 103 Phone: 7143269188 e-Mail: MODEL.BUILDERS@YAHOO.COM Printed: Tuesday, June 18, 2024 11:38:28 AM 13 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 FINAL**JFU 9/14/2020 9/14/2020 DISAPPROVE D eTRAKiT Inspection Request -SUBMIT THE ELECTRICAL PLAN REVISION FOR REVIEW, SEE INSPECTION NOTES FROM 7/28/2020 -COMPLETE THE BUSINESS LICENSE ISSUANCE PROCESS -PROVIDE A DIRECT ELECTRICAL CONNECTION WITH DISCONNECT FOR THE WATER HEATER -ONE OF THE HAND SINKS IN THE MAIN ROOM MUST BE ACCESSIBLE PER CBC 11B-606 -PROVIDE NRCI AND NRCA FORMS FOR INDOOR LIGHTING FINAL**AOR 9/16/2020 9/16/2020 DISAPPROVE D ALL ITEMS CORRECTED WITH EXCEPTION TO PROVIDING LIGHTING INSTALLATION AND ACCEPTANCE FORMS. FINAL**AOR 9/21/2021 9/21/2021 APPROVED FOUND OPEN PERMIT DURING 'EXPIRED PERMIT AUDIT' - BASED ON FORMS ATTACHED 10/6/2020 BEING APPROVAL, BUT NEVER FOLLOWED UP WITH PREVIOUSLY, THE STATUS IS BEING UPDATED TO SHOW THE WORK HAS SINCE BEEN COMPLETED. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PLANNING (2 WK) SIJIFREDO FERNANDEZ 2/14/2020 2/28/2020 2/18/2020 READY FOR APPROVAL 1ST PUBLIC WORKS (2 WK)AMY YU 2/14/2020 2/28/2020 2/27/2020 COMPLETE NO COMMENTS 1ST FIRE (2 WK)KOHL HETRICK 2/14/2020 2/28/2020 3/6/2020 REVISIONS REQUIRED PARENT PROJECTS Printed: Tuesday, June 18, 2024 11:38:28 AM 14 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 1ST PERMIT TECH (1 DAY) AARON HICKSON 2/14/2020 2/18/2020 2/18/2020 COMPLETE 1ST BLDG COMPLETE (2 WK)INTERWEST 2/14/2020 2/28/2020 3/3/2020 REVISIONS REQUIRED 1ST BLDG NS (2 WK)JAKE FUSON 2/14/2020 2/28/2020 3/12/2020 REVISIONS REQUIRED SEE 1ST REVIEW - COMPLETE CORRECTION LIST. 2ND BLDG COMPLETE (1 WK)INTERWEST 4/7/2020 4/14/2020 4/13/2020 REVISIONS REQUIRED 2ND BLDG NS – ETRAKIT (1 WK)JAKE FUSON 4/7/2020 4/14/2020 4/15/2020 REVISIONS REQUIRED SEE 2ND REVIEW CORRECTION LIST. FIRE GENERAL CONDITIONS Fire Department approval is based upon the 2019 CBC requirements for B Occupancies with an occupant load of 24. It is prohibited to use, process or store any materials in the occupancy that would classify it as a Group H occupancy, without further review and approval. DEFERRED SUBMITTALS REQUIRED 1) FIRE SPRINKLER – Tenant Improvement plans must be submitted and reference the installing contractor performing the work. Permit fees will be required. 2) FIRE ALARM/MONITORING SYSTEM – Tenant Improvement plans must be submitted per NFPA 72 as required by the California Building Code, California Fire Code and designed in accordance with adopted standards. A C-10 licensed contractor must submit plans to the Fire Department office for review and approval prior to installation. Permit fees will be required. PRIOR TO FINAL INSPECTION 1) Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. 2) Approved building address shall be placed in Printed: Tuesday, June 18, 2024 11:38:28 AM 15 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 BOND INFORMATION 2ND FIRE - ETRAKIT (1 WK) KOHL HETRICK 4/7/2020 4/14/2020 4/15/2020 READY FOR APPROVAL SEE NOTES FOR CONDITIONS such a position as to be plainly visible and legible from the street and rear access if applicable. Building address numbers shall be a minimum of 12”. Minimum 6” tall suite addressing shall be provided to both the front and rear entrances. All addressing must be legible and of a contrasting color with the to be visible from the street at all hours. 3) Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. All new and existing portable fire extinguishers shall have current annual servicing performed and tagged. 4) A durable sign stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" shall be placed on or adjacent to the front exit doors. The sign shall be in letters not less than one inch high on a contrasting background (A <300, B, F, M and S). 5) Illuminated Exit Signage and Egress Illumination placement and functional test will be witnessed by OFM Fire Inspector at time of final inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. 3RD BLDG NS – ETRAKIT (1 WK)JAKE FUSON 4/23/2020 4/30/2020 5/4/2020 APPROVED 1ST BLDG NS - ETRAKIT (1 DAY)JAKE FUSON 9/15/2020 9/16/2020 9/15/2020 APPROVED REVISION 1 REVISION 1 - ELECTRICAL DISTRIBUTION EQUIPMENT REVISION (REVISED SINGLE LINE DIAGRAM, POWER PLAN & PANEL SCHEDULE). Printed: Tuesday, June 18, 2024 11:38:28 AM 16 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/14/2020 AARON HICKSON 1ST SUBMITTAL PLAN SET - 1 OF 4 1OF4.pdf 1 DOC 2/14/2020 AARON HICKSON 1ST SUBMITTAL PLAN SET - 2 OF 4 2OF4.pdf 1 DOC 2/14/2020 AARON HICKSON 1ST SUBMITTAL PLAN SET - 3 OF 4 3OF4.pdf 1 DOC 2/14/2020 AARON HICKSON 1ST SUBMITTAL PLAN SET - 4 OF 4 4OF4.pdf 1 DOC 10/6/2020 EtrakitContractor Electrical report La.Quinta.E.report5.pdf 1 DOC 10/6/2020 EtrakitContractor Electrical report La.Quinta.E.report_1.pd f 1 DOC 10/6/2020 EtrakitContractor Electrical report La.Quinta.E.report1.pdf 1 DOC 10/6/2020 EtrakitContractor Electrical report La.Quinta.E.report2.pdf 1 DOC 10/6/2020 EtrakitContractor Electrical report La.Quinta.E.report3.pdf 1 DOC 10/6/2020 EtrakitContractor Electrical report La.Quinta.E.report4.pdf 1 DOC 4/6/2020 EtrakitPublicReg 2ND SUBMITTAL - CORRECTION RESPONSES (BUILDING) BCOM2020-0011 - 1ST REVIEW - COMPLETE CORRECTION LIST _1.pdf 1 DOC 4/6/2020 EtrakitPublicReg 2ND SUBMITTAL - CORRECTION RESPONSES (FIRE) BCOM2020-0011 - LQ NAIL BAR TI - FIRE CORRECTIONS_1.pdf 1 DOC 4/7/2020 EtrakitPublicReg 2ND SUBMITTAL - PLAN SET LA QUINTA NAIL BAR- CORRECTED FILES.pdf 1 DOC 4/23/2020 EtrakitPublicReg 3RD SUBMITTAL - PLAN SET BCOM2020-0011 Nail Salon plans.pdf 1 DOC 4/23/2020 EtrakitPublicReg 3RD SUBMITTAL - CORRECTION RESPONSES 2ND CORRECTIONS RESPOND.pdf 1 Printed: Tuesday, June 18, 2024 11:38:28 AM 17 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/23/2020 EtrakitPublicReg FLOOR SINK BASKET floor sink-GWS-FS- BSI.pdf 1 DOC 4/23/2020 EtrakitPublicReg PIPE HOOK Plumbing IAPMO.pdf 1 DOC 7/17/2020 EtrakitPublicReg SOFIT DETAIL FOR INSPECTOR SOFIT DETAIL.pdf 1 DOC 3/3/2020 INTERWEST 1ST REVIEW - INTERWEST INVOICE La Quinta - 202001524; BCOM2020-0011 - Invoice 57773.pdf 1 DOC 4/13/2020 INTERWEST 2ND REVIEW - INTERWEST COMMENTS 202001524 PC2 - BCOM2020-00011 46243 79070 HWY 111.docx 0 DOC 4/13/2020 INTERWEST 2ND REVIEW - INTERWEST INVOICE La Quinta - 202001524; BCOM2020-0011 - Invoice 58845.pdf 0 DOC 3/12/2020 JAKE FUSON 1ST REVIEW - REDLINED PLAN SET BCOM2020-0011 - 1ST REVIEW - REDLINED PLAN SET.pdf 1 DOC 3/12/2020 JAKE FUSON 1ST REVIEW - COMPLETE CORRECTION LIST BCOM2020-0011 - 1ST REVIEW - COMPLETE CORRECTION LIST .pdf 1 DOC 4/16/2020 JAKE FUSON 2ND REVIEW CORRECTION LIST BCOM2020-0011 - 2ND REVIEW CORRECTION LIST.pdf 1 DOC 5/4/2020 JAKE FUSON APPROVED PLAN SET BCOM2020-0011 - APPROVED PLAN SET.pdf 1 DOC 5/5/2020 JAKE FUSON PATH OF TRAVEL UPGRADE DETERMINATION BCOM2020-0011 - PATH OF TRAVEL UPGRADE DETERMINATION.pdf 1 Printed: Tuesday, June 18, 2024 11:38:28 AM 18 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/15/2020 JAKE FUSON REVISION 1 - 1ST SUBMITTAL BCOM2020-0011 - REVISION 1 - 1ST SUBMITTAL.pdf 1 DOC 9/15/2020 JAKE FUSON REVISION 1 - APPROVED ELECTRICAL PLAN BCOM2020-0011 - REVISION 1 - APPROVED ELECTRICAL PLAN.pdf 1 DOC 9/25/2020 JAKE FUSON CERTIFICATE OF ACCEPTANCE - INDOOR LIGHTING - NRCA-LTI-02 -A BCOM2020-0011 - NRCA-LTI-02-A.pdf 1 DOC 3/17/2020 JACK LIMA 1ST REVIEW - INTERWEST COMMENTS 202001524 PC1 - BCOM2020-00011 46243 79070 HWY 111.docx 0 DOC 5/7/2020 JACK LIMA CHANGE OF CONTRACTOR CHANGE OF CONTRACTOR.pdf 0 DOC 5/7/2020 JACK LIMA OpenReceipt - UNPAID and TRANSFERRED BL CHARGES OpenReceipt.pdf 0 DOC 3/6/2020 KOHL HETRICK 1ST REVIEW - FIRE CORRECTIONS BCOM2020-0011 - LQ NAIL BAR TI - FIRE CORRECTIONS.pdf 1 Printed: Tuesday, June 18, 2024 11:38:28 AM 19 of 19 Permit Details City of La Quinta PERMIT NUMBER BCOM2020-0011 CT.BKR/ BKR/CT.# LTG REC M/SC A B C POLE POLE A B C M/SC REC LTG #PEDICURE 1. 2 960 20/2 20/1 1350 1 2. REFRIG.PEDICURE 3. 2 960 20/2 20/1 2250 1 4. WASHERPEDICURE 5. 2 960 20/2 20/1 1800 1 6. DRYERPEDICURE 7. 2 960 20/2 20/1 1200 2 8. WAITING.1PEDICURE 9. 2 960 20/2 20/1 1800 2 10. GFI. RESTROOM 1.2PEDICURE 11. 2 960 20/2 20/1 1800 4 12. WAX-1. HALL WAYPEDICURE 13. 2 960 20/2 20/1 1800 4 14. WAX-2. GFI. COUNTER 1PEDICURE 15. 2 960 20/2 20/1 1800 4 16. WAX-2. GFI. COUNTER 2PEDICURE 17. 2 960 20/2 20/1 1200 3 18. RECEPTION. NAIL DRYERNAILS BAR 19. 4 1800 20/1 20/1 1200 2 20. WAITING.2NAILS BAR 21. 4 1800 20/1 20/1 1200 2 22. TELEVISIONNAILS BAR 23. 4 1800 20/1 20/12 24. TELEVISIONNAILS BAR 25. 4 1800 20/1 20/1 300 1 26. ROOF FANRESTROOM FAN 1.2 (TANDEM BREAKER) 27. 2 60 20/2 20/2 120 2 28.LAUNDRY FAN. BOOSTER FAN (TANDEM BREAKER)EXISTING AC 1 (5 TONS) 29. 1 1 5840 30/3 30/3 5840 1 1 30. EXISTING AC 2 (5 TONS)- 31. 5840 30/3 30/3 5840 32. -- 33.5840 30/3 30/3 5840 34. -TIMER 35. 1 24 20/1 20/1 1200 7 36. EXIT SIGN/ EMERGENCY LIGHTSHOW WINDOW 37. 1 1800 20/1 20/1 393 15 38. LIGHTSLIGHTS 39. 44 908 20/1 20/1 988 34 40. LIGHTS41.20/1 20/1 760 40 42. LIGHTS12344 12380 11428 13350 13403 11928 Sub totalTotal A Phase =Total B Phase =Total C Phase = EXISTING PANEL 25694 VA25783 VASub totalOUTLETSPANEL : "P"BREAKER : MOUNTINGOUTLETS= 207A23356 VAVOLTAGE / PHASE : 120/208 3 PH. 4W.VOLT AMPS74833 VABUS : 225 AMPS 65KAICTOTAL LOAD =VOLT AMPSREVISION 1BCOM2020-0011REVISED SINGLE LINEDIAGRAM, POWER PLAN ANDPANEL SCHEDULE09/15/2020