Loading...
BMCH2022-0394 - Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards. This program developed by EnergySoft Software – www.energysoft.com. , 79220 Hwy 111 Best Buy #1020 La Quinta, CA 92253 103 W. El Portal #c Vander Veen Engineering Consultants Jason Vander Veen San Clemente, CA 92672 7/18/2022 08/20/2022 BMCH2022-0394 HVAC CHANGE OUT - (1) ROOF TOP 10-TON PACKAGE UNIT, WEIGHT NOT TO EXCEED 1,600LBS AS PERMITTED ON SHELL BUILDING PLANS. 2019 CALIFORNIA BUILDING CODES. TABLE OF CONTENTS Cover Page Table of Contents Form NRCC-MCH-E Mechanical Systems 1 2 3 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E This document is used to demonstrate compliance for mechanical systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in §140.4, or §141.0(b)2  for alterations. Project Name: Best Buy #1020 Report Page: (Page 1 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 A. GENERAL INFORMATION 01 Project Location (city)La Quinta 04 Total Conditioned Floor Area 2000 02 Climate Zone 5 05 Total Unconditioned Floor Area 0 03 Occupancy Types Within Project:06 # of Stories (Habitable Above Grade)1 Office (B)Retail (M)Non-refrigerated Warehouse (S) Hotel/ Motel Guest Rooms (R-1)School (E)Healthcare Facility (I) High-Rise Residential (R-2/R-3)Relocatable Class Bldg (E)Other (write in)See Table J B. PROJECT SCOPE This table Includes mechanical systems or components that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in §140.4, or §141.0(b)2  for alterations. 01 02 03 Air System(s)Wet System Components Dry System Components Heating Air System Water Economizer Air Economizer Cooling Air System Pumps Electric Resistance Heat Mechanical Controls System Piping Fan Systems Mechanical Controls (existing to remain, altered or new)Cooling Towers Ductwork (existing to remain, altered or new) Chillers Ventilation Boilers Zonal Systems/ Terminal Boxes 08/20/2022 BMCH2022-0394 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 2 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 C. COMPLIANCE RESULTS Table C will indicate if the project data input into the compliance document is compliant with mechanical requirements. This table is not editable by the user. If this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D., or the table indicated as not compliant for guidance. 01 AND 02 AND 03 AND 04 AND 05 AND 06 AND 07 AND 08 09 System Summary §110.1, §110.2, §140.4  Pumps §140.4(k)  Fans/ Economizers §140.4(c), §140.4(e)  System Controls §110.2, §120.2, §140.4(f)  Ventilation §120.1  Terminal Box Controls §140.4(d)  Distribution §120.3, §140.4(l)  Cooling Towers §110.2(e)2 Compliance Results (See Table F)(See Table G)(See Table H)(See Table I)(See Table J)(See Table K)(See Table L)(See Table M) Yes AND AND Yes AND Yes AND Yes AND AND Yes AND COMPLIES Mandatory Measures Compliance (See Table Q for Details)COMPLIES D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 3 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) This table is used to demonstrate compliance for mechanical equipment with mandatory requirements found in §110.1  and §110.2(a)  and prescriptive requirements found in §140.4(a), §140.4(b)  and §140.4(k)  or §141.0(b)2  for alterations. Dry System Equipment Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters) 01 02 03 04 05 06 07 08 09 10 11 Name or Item Tag Equipment Category per Tables 110.2 Equipment Type per Tables 110.2 / Title 20 Smallest Size Available1 §140.4(a)  Equipment Sizing per Mechanical Schedule (kBtu/h) §140.4 (a&b) Heating Output2,3 Cooling Output2,3 Load Calculations3,4 Per Design (kBtu/h) Rated (kBtu/h) Supp. Heating Output (kBtu/h) Sensible Per Design (kBtu/h) Rated (kBtu/h) Total Heating Load (kBtu/h) Total Sensible Cooling Load (kBtu/h) Rooftop- Replacement 10 Tons Unitary Heat Pumps Air-cooled, pkg (3 phase)NA: Load Controls 72.91 120 0 103.08 94.59 34.45 105.39 1FOOTNOTES: Equipment shall be the smallest size, within the available options of the desired equipment line, necessary to meet the design heating and cooling loads of the building per §140.4(a). Healthcare facilities are excepted. 2It is common practice to show rated output capacity on the equipment schedule. Sensible cooling output comes from specification sheet tables. 3 If equipment is heating only, leave cooling output and load blank. If equipment is cooling only, leave heating output and load blank. 4 Authority Having Jurisdiction may ask for load calculations used for compliance per §140.4(b). STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 4 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) Dry System Equipment Efficiency (other than Package Terminal Air Conditioners (PTAC) and Package Terminal Heat Pumps (PTHP)) 01 02 03 04 05 06 07 08 09 Name or Item Tag Size Category (Btu/h) Heating Mode Cooling Mode Rating Condition ( °F) Efficiency Unit Minimum Efficiency Required per Tables 110.2 / Title 20 Design Efficiency Efficiency Unit Minimum Efficiency Required per Tables 110.2 / Title 20 Design Efficiency Rooftop- Replacement 10 Tons >=65,000 and <135,000 COP 3.3 3.3 EER IEER 11 12.2 11.3 12.9 G. PUMPS This section does not apply to this project. H. FAN SYSTEMS & AIR ECONOMIZERS This table is used to demonstrate compliance with prescriptive requirements found in §140.4(c),§140.4(e)  and §140.4(m)  for fan systems. Fan systems serving only process loads are exempt from these requirements and do not need to be included in Table H. System Name: Rooftop- Replacement 10 Tons Economizer:1 NA: Special OA filtration Economizer Controls: Designed per §140.4(e)  and (m)System Fan Type:Constant Volume 01 02 03 04 05 06 07 08 Fan Name or Item Tag Fan Function Qty Maximum Design Supply Airflow (CFM)HP Unit2 Design HP Fan Power Pressure Drop Adjustment - Table 140.4-B Device Design Airflow through Device (CFM) SF Supply 1 4000 BHP 1.5 NA NA Total System Design Supply Airflow (CFM):4000 Total System Design (B)HP:1.5 Maximum System Fan Power (B)HP: 1 FOOTNOTES: Computer room economizers must meet requirements of §140.9(a)  and will be documented on the NRCC-PRC-E document. 2 The unit used for HP must be consistent for all fans within a system. STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 5 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 I. SYSTEM CONTROLS This table is used to demonstrate compliance with mandatory controls in §110.2  and §120.2  and prescriptive controls in §140.4(f)  and (n) or requirements in §141.0(b)2E  for altered space conditioning systems. 01 02 03 04 05 06 07 08 09 System Name System Zoning Conditioned Floor Area Being Served (ft2) Thermostats §110.2(b)  & (c)1, §120.2(a)or §141.0(b)2E  Shut-Off Controls §120.2(e)  Isolation Zone Controls §120.2(g)  Demand Response §110.12  and §120.2(b)  Supply Air Temp. Reset §140.4(f)  Window Interlocks per §140.4(n)  Rooftop-Replacement 10 Tons Single zone <= 25,000 ft2 Setback NA: 7 day per §120.2(e)1  4 Hour Timer NA: Serves temp. sensitive process NA: Alteration NA: Alteration Project 1FOOTNOTES: Gravity gas wall heaters, gravity floor heaters, gravity room heaters, non-central electric heaters, fireplaces or decorative gas appliances, wood stoves are not required to have setback thermostats. *Notes: Controls with a * require a note in the space below explaining how compliance is achieved. EX: system 1: SA Temp Reset: Exempt because zones compliant with §140.4(d) ; EXCEPTION 1 to §140.4(f)  J. VENTILATION AND INDOOR AIR QUALITY This table is used to demonstrate compliance with mandatory ventilation requirements in §120.1  and §120.2(e)3B  for all nonresidential, high-rise residential and hotel/motel occupancies. For alterations, only ventialtion systems being altered within the scope of the permit application need to be documented in this table. In lieu of this table, the required outdoor ventilation rates and airflows may be shown on the plans or the calculations can be presented in a spreadsheet. 01 Check the box if the project is showing ventilation calculations on the plans, or attaching the calculations instead of completing this table. 02 Check this box if the project included Nonresidential or Hotel/Motel spaces Check this box if the project included new or altered high-rise residential dwelling units. 03 Check the box if the project is using natural ventilation in any nonresidential or hotel/motel spaces to meet required ventilation rates per §120.1(c)2. Nonresidential and Hotel/ Motel Ventilation Systems 04 05 06 07 System Name Rooftop-Replacement 10 Tons System Design OA CFM Airflow1 500 System Design Transfer Air CFM 0 Air Filtration per §120.1(c)  and §141.0(b)2 2 Provided per §120.1(c)  (NR and Hotel/Motel)) 08 09 10 11 12 13 14 15 16 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 6 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 J. VENTILATION AND INDOOR AIR QUALITY Space Name ot item Tag Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  DCV or Sensor Controls per §120.1(d)3, §120.1(d)5, and §120.1(e)3 6Occupancy Type4 Conditioned Floor Area (ft2) # of Shower heads/ toilets # of people5 Required Min OA CFM Required Min CFM Provided per Design CFM Retail Retail sales 2000 500 0 0 DCV Provided per §120.1(d)4  Occ Sensor NA: Not required space type 17 Total System Required Min OA CFM 500 18 Ventilation for this System Complies?Yes 1 FOOTNOTES: System CFM should include both mechanical and natural ventilation for the zone/system 2 Air filtration requirements apply to the following three system types per §120.1(c)1A : space conditioning systems utilizing ducts to supply air to occupiable space; supply-only ventilation systems providing outside air to occupiable space; supply side of balanced ventilation systems including heat recovery and energy recovery ventilation systems providing outside air to occupiable space. 3 Uniform Mechanical Code may have more stringent ventilation requirements; the most stringent code requirement takes precedence. 4 See Standards Tables 120.1-A and 120.1-B. 5 For lecture halls with fixed seating, the expected number of occupants shall be shall be determined in accordance with the California Building Code. 6 §120.2(e)3  requires systems serving rooms that are required by §130.1(c)  to have lighting occupancy sensing controls to also have occupancy sensing zone controls for ventilation. Examples of spaces which require lighting occupancy sensors include offices 250ft2 or smaller, multipurpose rooms less than 1,000 ft2, classrooms, conference rooms, restrooms, aisles and open areas in warehouses, library book stack aisles, corridors, stairwells, parking garages, and loading and unloading zones, unless excepted by §130.1(c). K. TERMINAL BOX CONTROLS This section does not apply to this project. L. DISTRIBUTION (DUCTWORK and PIPING) This table is used to show compliance with mandatory pipe insulation requirements found in §120.3  and prescriptive requirements found in §140.4(l)  for duct leakage testing. Duct Leakage Sealing STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 7 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 L. DISTRIBUTION (DUCTWORK and PIPING) The answers to the questions below apply to the following duct systems:Rooftop-Replacement 10 Tons Duct leakage testing triggered for these systems?No 11 No The scope of the project includes only duct systems serving healthcare facilities 12 Yes Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space-conditioning system. 13 Yes The space conditioning system serves less than 5,000 ft2 of conditioned floor area. 14 No The combined surface area of the ducts in the following locations is more than 25% of the total surface area of the entire duct system: Outdoors In a space directly under a roof that has a U-factor greater than the u-factor of the ceiling, or if the roof does not meet the requirements of §140.3(a)1B  or if the roof has fixed vents or openings to the outside/ unconditioned spaces In an unconditioned crawl space In other unconditioned spaces 15 The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos. 16 The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2. 17 Yes Duct system shall be sealed in acordance with the California Mechanical Code M. COOLING TOWERS This section does not apply to this project. N. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential_Documents/NRCI/ Form/Title Field Inspector Pass Fail NRCI-MCH-01-E - Must be submitted for all buildings STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 8 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 O. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential_Documents/NRCA/ Form/Title Systems/Spaces To Be Field Verified Field Inspector Pass Fail NRCA-MCH-02-A - Outdoor Air must be submitted for all newly installed HVAC units. Note: MCH-02-A can be performed in conjunction with MCH-07-A Supply Fan VFD Acceptance (if applicable) since testing activities overlap. York XP120C; NRCA-MCH-03-A - Constant Volume Single Zone HVAC NOTE: This form does not automatically move to "Yes'. If Constant Volume Single Zone HVAC Systems are included in the scope, permit applicant should move this form to "Yes". York XP120C; NRCA-MCH-06-A Demand Control Ventilation Systems must be submitted for all systems required to employ demand controlled ventilation (refer to §120.1(c)3 ) can vary outside ventilation flow rates based on maintaining interior carbon dioxide (CO2) concentration setpoints. York XP120C; NRCA-MCH-11-A Automatic Demand Shed Controls York XP120C; P. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION There are no NRCV forms required for this project. Q. MANDATORY MEASURES DOCUMENTATION LOCATION This table is used to indicate where mandatory measures are documented in the plan set or construction documentation. 01 02 Compliance with Mandatory Measures documented through MCH Mandatory Measures Note Block Yes M-Sheets STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Best Buy #1020 Report Page: (Page 9 of 9) Project Address: 79220 Hwy 111 Date Prepared: 7/18/2022 Registration Number:Registration Date/Time:Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Schema Version: rev 20200601 Report Generated: 2022-07-18 22:42:44 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Jason Vander Veen Documentation Author Signature: Company: Vander Veen Engineering Consultants Signature Date: 2022-07-18 Address: 103 W. El Portal #c CEA/ HERS Certification Identification (if applicable): City/State/Zip: San Clemente CA 92672 Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Compliance is true and correct. 2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3.The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5.I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: VanderVeen Engineering Consultants, Inc Responsible Designer Signature: Company: VanderVeen Engineering Consultants, Inc Date Signed: 2022-07-18 Address: 28362 Vincent Moraga, Suite A1 License: City/State/Zip: Temecula CA 92591 Phone: M34874