Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BWFE2022-0413
DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Wall / Fence BWFE2022-0413 50695 CALLE GUAYMAS 770094005 $14,000.00 Declaration / Acknowledgement BUILDING PERMIT Ottigta CALIFORNIA PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 08/04/2022 ISSUED DATE: 08/22/2022 Owner: 41 CALLE GUAYMAS LLC 1054 RAILROAD, La Quinta, CA 922472 Applicant: STEPHEN D KEALER PO Box 1418, La Quinta, CA 92247 Contractor: STEPHEN D KEALER PO Box 1418, La Quinta, CA 92247 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.Ieg info.ca.gov/calaw. html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 7/5/24 9:24 am Page 1 of 3 BUILDING PERMIT Permit Type: Wall / Fence Permit Number: BWFE2022-0413 Property Address: 50695 CALLE GUAYMAS Use of Permit MELKESIAN/90LF OF COMBO WALL AND 100LF OF GARDEN WALL AT P/L *** MELKESIAN/90LF OF 6' GARDEN W/1'-6" RETAINING AI' 100LF OF 6' GARDEN WALL AT WEST AND SOUTH PROPERTY LINES.[PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA BUILDING CODES #III# MELKESIAN/90LF OF COMBO WALL AND 100LF OF GARDEN WALL AT P/L *** REV-1 100LF OF 6 FOOUT GARDEN WALL AT REAR PL WILL BE CITY STANDARD OPTION A #III# MELKESIAN/90LF OF COMBO WALL AND 100LF OF GARDEN WALL AT P/L *** REVISION 2 - 100LF OF 6' GARDEN W/1' RETAINING AT SOUTH PROPERTY LINES. [GOUVIS ENGINEERING]. 2019 CALIFORNIA BUILDING CODES. Construction Details Combination Retaining 85 Wall Linear Footage Total Block Wall LF 100 Valuation Details Financial Information Invoice No. PERMIT-BWFE2022-041 3 Fee WALL/FENCE - FIRST 100LF RECORDS MANAGEMENT FEE TECHNOLOGY ENHANCEMENT FEE RETAINING/COMBINATION WALL EA 5OLF HOURLY CHARGE - CITY BUILDING STAFF BSAS SB1473 FEE WALL/FENCE - FIRST 100LF PC Total for Invoice PERMIT-BWFE2022-0413 Fee Amount Amount Paid $55.58 $55.58 $11.00 $11.00 $5.00 $5.00 $33.34 $33.34 $87.50 $87.50 $1.00 $1.00 $69.47 $69.47 $262.89 $262.89 Grand Total for Permit $262.89 $262.89 Workflow / Inspections Workflow Step / Action Name Inspections v.1 FINAL** v.2 FINAL** v.1 BOND BEAM v.4 BOND BEAM v.3 FOOTINGS v.4 BOND BEAM v.2 FOOTINGS v.3 BOND BEAM v.1 FOOTINGS v.2 FOOTINGS v.1 Action Type Inspection Inspection Inspection Inspection Inspection Inspection Inspection Inspection Inspection Inspection Start Date End Date 08/04/2022 0:00 Printed: 7/5/24 9:24 am Page 2 of 3 BUILDING PERMIT Permit Type: Permit Number: Property Address: Wall / Fence BWFE2022-0413 50695 CALLE GUAYMAS Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 7/5/24 9:24 am Page 3 of 3 HAVEN ENTERPRISES INC. November 7, 2022 Bob Bland City of La Quinta Department of Building & Safety 78-495 Calle Tampico La Quinta, CA 92253 Re: Block Wall Permit BWFE2022-0413 50-695 Calle Guaymas La Quinta, CA 92253 Bob: The Property Line rear wall has been built to the cities standard and provides a footing that encroaches on to the adjacent lot: 50-710 Calle Quito, La Quinta 92253. I have approved this as the owner/general contractor of both lots. Thank -you for bringing this to my attention and accepting this letter as documentation and acknowledgment of this condition. Respectfully submitted, Stephen D Kealer CA General Contractors License No. 1083458 PO Box 1418 La Quinta CA 92247 (760) 992-4855 I skealer@aol.com R:\AutoCAD\Projects\113K-001 Calle Guaymas 41\dwg\113k1gp01.dwg, GP02, 11/12/2021 9:44:16 AM TW = 43.8) EX. WALL FG = 40.50 EX PAD =39.0 I M 40.5 FG 40.30 TG SECTION A -A SCALE: 1 "=2' 41.00 FF LOT 42 43.8 TW NOTE: LOT 48 & 41 HAVE SAME OWNER. WALL TO BE CONSTRUCTED ON PROPERTY LINE 40.5 FG 38.9 EG / (38.4 EG) 43.7 \t f \ 40.5 FG * ROOT ` BALL 46.50 TW 40.50 TRW 39.33 TF r.M0.30 TG 38.50 INV CT; 40.30 TG 38.69 INV EX. BLOCK WALL (38.6 EG) (43.8 TW) 040.30 TG 38.55 INV (EXISTING RESIDENCE) (39.06 FS@GARAGE) A (39.00 PAD) N01E 10 QON1R4CTOR: STORMWATER SHALL BE ALLOWED TO FLOW THROUGH A SINGLE OPENING IN THE WALL AT ELEVATION 40.45, WITH A MINIMUM OF 128 SQ IN OPENING, IN THE EVENT OF FAILURE OF THE STORM DRAIN SYSTEM (EMERGENCY OVERFLOW). ENGINEER OF RECORD WILL NOT CERTIFY FINAL GRADING WITHOUT THIS OVERFLOW. CORE DRILLING HOLES IN THE WALL IS INADEQUATE FOR AN EMERGENCY OVERFLOW. Know what's below. Call before you dig. 40.5 FG 0.30 TG 38.35 INV W M z (43.8 TW) EX. METAL GATE 38.9 EG 0.30 TG 38.23 INV 40.5 FG 0 EX. ROSE11 HEDGE O8.50 TG 36.501NV 37.95 FL !al v. 38.47 TAG.ON.CURB SITE BENCHMARK (38.43 TP)/ 40.30 TG IN 39.00 IN (38.7 EG) 46.50 TW 40.50 TRW,-,-; 39.33 TF 9 0 (38.6 EG) 39 =2°03'44 R=1430.00' L=51.47' 38.50 TC (37.99 FL (38.7 EG) SPA - 42.75 FS - =1400' (38.45 TP)/. 46.33 TW 40.33 TF ki'701sz'w 0.5% oI CI)I �I \ I ROOT \ I BALL • 39.46 FS LOT 48 (VACANT) (38.6 EG) (38.9 EG) o I L la 50 FG/HP POOL COPING 40.75 FS -"-FOUNTAIN //////z/z/zz zzi (VACANT) 41.00 FF 40.50 PAD 1' (38.7 EG) 40.96 FS (38.8 EG) 40.46 FS A I ROOT I\ BALL I I� --r EXISTING CURB AND GUTTER /38.61 TC '38.12 FL CALLS 38.51 TP 0.5% 40.96 FS 1\41.00 FS 40.77 FS 39.3 TOE 0.30 TG 38.70 INV 7.N.0 EG 14'®1 % 40.96 FS (39.4 TOE) 40.77 F 45.9 TW 40.0 TOP AC AC 40.96 FS ' - 38.35 TG -GRADE BREAK • - - GUAYMAS © p 0 N 0 39.8 EG EX. WOOD FENCE 457 TW 45.6 TW (40.1 EG) 46.33 TW 40.33 TF 40.5 FG 40.30 TG it 38.50 IN 38.42 INV 40.20 TG I 38.29 IN 45.7 TW) 11 40.5 FG N NORTH -11.117111121) GRAPHIC SCALE 10 0 5 10 BWFE2022-0413 20 40 CI TY OF LA CQU N TA BULI]NGOVI3ON REVI EYED FOR COCE COIIRLI AV CE BY: J.ANAYA DE: 0812012022 MELKESIAN/90LF OF 6' GARDEN W/1'-6" RETAINING AND 100LF OF 6' GARDEN WALL AT WEST AND SOUTH PROPERTY LINES.[PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA BUILDING CODES. 40.20 TG 1 LOT 40 38.09 INV (EXISTING RESIDENCE) (40.08 FS@GARAGE) (40.1 TOP) (40.0 PAD) 40.5 EX. BLOCK WALL FG 44.2 TW 38.9 TOE EX. HEADER 38.66 TG 36.66 IN 3 66 TC NOTE: (38.20 FL)- - - - DRIVEWAY APPROACH REQUIRES A SEPARATE PERMIT AND INSPECTION FROM THE CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT. ( IN FEET ) 1 inch = 10 ft. BASIS OF BEARINGS: NORTH PROPERTY LINE OF LOT 41 AS N 87°32' E, PER MB 21/61-62 BENCHMARK: CITY OF LA QUINTA NO. 255 3.5" BRASS DISK IN CURB, FLUSH. 70 FT WEST OF E. C. R OF THE NORTHWEST CURB RETURN AT THE INTERSECTION OF CALLE TAMPICO AND WASHINGTON Si ELEVATION=(38.947) NAVD88 SITE BENCHMARK: TAG ON CURB AT THE PROPERTY LINE EXTENSION OF LOTS 41 & 42. ELEVATION=(38.47 TAG ON CURB) SITE BENCHMARK: -0- INDICATES THE BENCHMARK AT THE SITE WHICH THE ENGINEER OF RECORD SHALL USE TO CERTIFY PAD ELEVATION AND FINAL GRADING CERTIFICATION. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES BETWEEN THIS BENCHMARK AND THE BENCHMARK USED BY THE CONTRACTOR PRIOR TO ANY GRADING. SOURCE OF TOPOGRAPHY: THE TOPOGRAPHY SHOWN HEREON WAS OBTAINED BY A FIELD SURVEY BY FEIRO ENGINEERING, INC ON 7/2/2021 DEMOLITION NOTES AND QUANTITIES ESTIMATE: DESCRIPTION QTY UNIT O DEMOLISH AND DISPOSE EXISTING TREE/STUMP, SEE LANDSCAPE PLANS 2 EA CONSTRUCTION NOTES: DESCRIPTION O CONSTRUCT AREA DRAIN PER DETAIL ON SHEET 1 O CONSTRUCT 4" SDR-35 PVC DRAIN PIPE O CONSTRUCT BUBBLER BOX PER DETAIL ON SHEET 1 ONDS DURA-SLOPE CHANNEL (SHOWN PRE -SLOPED WITH 0.7% SLOPE). ALTERNATE CHANNELS SHALL HAVE MINIMUM 0.5% SLOPE. GRATE TYPE PER ARCHITECT. O CONSTRUCT PAVERS, SEE LANDSCAPE PLANS FOR COLOR/FINISH 0 CONSTRUCT RETAINING WALL PER SEPARATE PERMIT 07 CONSTRUCT D/W APPROACH PER CLQ STD NO 221 OCONSTRUCT 6' FREESTANDING BLOCK WALL CLQ BUILDING DEPT HANDOUT (PER SEPARATE PERMIT) OCONSTRUCT BLOCK WALL STANDARD ATOP 2' RETAINING WALL, FOOTING OPTION "A" PER CLQ BUILDING DEPT HANDOUT (PER SEPARATE PERMIT) LEGEND & H. P. G. B. E. G. E.G. F. S. F. F. PAD P T. W. T. R. W. W.S. B.W. T.F. B.F. R/W D/W T. C. F.L. T. H. E. P. T. P. T.G. INV [G] [E] (99.9) 99.9 (99) 99 _X2CE= TOP 2ZZZ=1_ZZZZIZ MgIf'_Z1111111/2_111111 PP • 0 TELE ❑ ❑ ABBREVIATIONS: CENTERLINE PROPERTY LINE HIGH POINT GRADE BREAK EXISTING GROUND FINISH GRADE FINISH SURFACE FINISH FLOOR ELEVATION PAD ELEVATION PLANTER TOP OF WALL TOP OF RETAINING WALL WATER SURFACE BOTTOM OF WALL TOP OF FOOTING BOTTOM OF FOOTING RIGHT-OF-WAY DRIVEWAY TOP OF CURB FLOW LINE TOP OF HEADER EDGE OF EXISTING PAVEMENT TOP OF PAVEMENT TOP OF GRATE INVERT ELEVATION "G" CHISELED ON CURB "S" CHISELED ON CURB "E" CHISELED ON CURB EXISTING ELEVATION PROPOSED ELEVATION PROPERTY LINE / RIGHT-OF-WAY CENTERLINE EXISTING CONTOUR FINISH CONTOUR DRAINAGE SWALE EXISTING SLOPE FINISH SLOPE EXISTING CURB AND GUTTER RETAINING WALL/DEEPENED FOOTING EXISTING RETAINING WALL/DEEPENED FOOTING EXISTING BLOCK WALL PROPOSED BLOCK WALL BLOCK WALL ATOP RETAINING WALL EXISTING BLOCK WALL ATOP RETAINING WALL SHEET FLOW CONCRETE MANHOLE TREE PALM TREE POWER POLE PIPE RISER TELEPHONE BOX ELECTRIC BOX WOOD FENCE CABLE TV STUMP BUSH HEDGE OF ROSE REVISIONS: DATE INITIAL APPROVED BY: DATE FEIRO Civil Engineering Land Surveying www.feiro.net P.O. Box 12980 Palm Desert, California 92255 (760) 346-8015 In the City of Lot qu,inta, PREPARED UNDER THE DIRECT SUPERVISION OF: Precise Grading Plan Lot 41, Desert Club Tract Unit No. 5 Per MB 21/61-62; APN 770-094-005 SHEET NUMBER: 2 OF 2 SHEETS .DWG FILE: 11JklgpOl.dwg LAYOUT.: GP02 ENGINEERING, inc RONALD K. FEIRO R.C.E. 52260 DATE FOR: 41 Calle Guaymas, LLC JOB NUMBER: 113K-001 Gouvisengineering over 60 years of design excellence December 5, 2022 Stephen D. Kealer 41 Calle Guaymas LLC 1054 Railroad Corona, CA 92882 Re: 50695 Calle Guaymas Retaining/Fence wall GECG Job No. 65758-301 Dear Mr. Kealer, consulting group inc. Under your request regarding the above -captioned project, we submit the following: After reviewing the inspector comments we did run the calculations for lap splice of #4 rebars and we do believe minimum 12" is acceptable. 8" CMU is acceptable for first 3 ft of retaining wall also #4 vertical rebars at 24" o/c is acceptable. If you have any questions please do not hesitate to contact this office. Sincerely, GOUVIS ENGINEERING CONSULTING GROUP, INC. Mike Houshmand, P.E. Senior Vice President Structural Department 949.752.1612 15 Studebaker Irvine, CA 92618 www.gouvisgroup.com Palm Springs, CA Pleasanton, CA Ho Chi Minh City, Vietnam couvise ee b j consulting group, inc. SKEET: ( JOB NO.:(OJ! /r/ 57 DATE: i2/5/ fl CUENT: sra✓g. )c&1te 7 CAI'ger-v,✓E (c )2 1$? SpL7C r = be, kii - 4.5" s id 9l3 Ths er b X I /tap 5;