Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2021-0707 Title 24
CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE Dare 02/11/2022 � C BRE2021-0707 - 50695 CALLE GUAYMAS MELKESIAN / 3,365SF SINGLE FAMILY DWELLING 3,365SF DWELLING - LOT 41 [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2019 CALIFORNIA BUILDING CODES. G Gouvisengineering over 60 years of design excellence consulting group inc. ENERGY CALCULATION (T-24) (A Custom Home) 50695 Calle Guaymas Custom Home 50695 Calle Guaymas, APN 770-094-005, La Quinta, County of Riverside, CA Gouvis Job No.: 65758 Developer: 41 Calle Guaymas LLC Architect: Bassenian Lagoni Architects Restrictive Notice: These designs, calculations, and specifications are the exclusive property of Gouvis Engineering Consulting Group. They are the subject of copyright and other legal protection. They may be used only by their intended recipient and only for the project depicted herein. No part of these calculations are to be copied, transferred, reproduced, nor can they be used, in whole or in part, by any other person or for any other project or structure, without the prior express written consent of Gouvis Engineering Consulting Group. © 2020 Gouvis Engineering Consulting Group Inc. - All Rights Reserved 949.752.1612 15 Studebaker Irvine, CA 92618 www.gouvisgroup.com Palm Springs, CA Pleasanton, CA Ho Chi Minh City, Vietnam CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 1 of 11) GENERAL INFORMATION 01 Project Name 50695 Calle Guaymas 02 Run Title Title 24 Analysis 03 Project Location 50695 Calle Guaymas 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.2 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) 270 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft2) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2) n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2) 3365 19 Glazing Percentage (%) 18.96% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available? Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2021-12-02 11:08:21 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-12-02 10:27:47 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 2 of 11) ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 48.1 23.5 Proposed Design 46.8 20.6 1.3 2.9 RESULT: 3: COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 6.09 kWdc • Proposed PV kWh output exceeds proposed electricity use by 4.8% which may violate NEM rules. Contact local utility. ENERGY USE SUMMARY Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating Space Cooling IAQ Ventilation Water Heating Self Utilization/Flexibility Credit Compliance Energy Total 1.85 85.91 2.2 5.95 n/a 95.91 2.32 82.95 2.2 4.88 0 92.35 -0.47 2.96 0 1.07 0 3.56 -25.4 3.4 0 18 n/a 3.7 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc) Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 6.46 NA Premium Fixed Microinverters true 150-270 n/a n/a <=7:12 96 100 Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-12-02 10:27:47 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 3 of 11) REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • PV module type: Premium • PV power electronics: Microinverters • Non-standard roof reflectance • Insulation below roof deck HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation • Kitchen range hood Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity HVAC Distribution System Verifications: • Duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- � CaICER)�, HERS P R O V I L r BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft') Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 50695 Calle Guaymas 3365 1 3 1 0 1 Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-12-02 10:27:47 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 4 of 11) ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Floor Plan Conditioned 3.5T1 3365 9.5 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Door Area (ft2) Tilt (deg) Top Exterior Wall 2x6 Floor Plan R-21 Wall R4 270 Front 891 369 90 Right Exterior Wall 2x6 Floor Plan R-21 Wall R4 0 Left 575 96 90 Bottom Exterior Wall 2x6 Floor Plan R-21 Wall R4 90 Back 530 122 90 Left Exterior Wall 2x6 Floor Plan R-21 Wall R4 180 Right 702 79 90 Garage Surface 2x6 Floor plan»_Garage R-15 Garage Surface n/a n/a 397 0 n/a Roof Floor Plan R-38 Roof Attic + R19 n/a n/a 3000 n/a n/a Roof 2 _Garage_ R-0 Roof Attic n/a n/a 693 n/a n/a Top Exterior Garage _Garage_ R-0 Wall 270 Front 37 0 90 Right Exterior Garage Garage R-0 Wall 0 Left 220 0 90 Bottom Exterior Garage Garage R-0 Wall 90 Back 311 192 90 Left Exterior Garage _Garage R-0 Wall 180 Right 89 0 90 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Garage Attic Garage Roof Cons Ventilated 3 0.1 0.85 No No Attic Floor Plan Attic RoofFloor Plan Ventilated 3 0.18 0.91 No No Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-12-02 10:27:47 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 5 of 11) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ftz) U-factor U-factor Source SHGC SHGC Source Exterior Shading (2) Window 2060 FX Window Top Exterior Wall 2x6 Front 270 1 24 0.3 NFRC 0.2 NFRC Bug Screen Window 6060 SL Window Top Exterior Wall 2x6 Front 270 1 36 0.3 NFRC 0.2 NFRC Bug Screen Window 6050 SL Window Top Exterior Wall 2x6 Front 270 1 30 0.3 NFRC 0.2 NFRC Bug Screen (2) Window 3020 FX Window Top Exterior Wall 2x6 Front 270 1 12 0.3 NFRC 0.2 NFRC Bug Screen (2) Window 3060 SH Window Top Exterior Wall 2x6 Front 270 1 36 0.3 NFRC 0.2 NFRC Bug Screen Window 8020 FX Window Top Exterior Wall 2x6 Front 270 1 16 0.3 NFRC 0.2 NFRC Bug Screen Window 8060 FX Window Top Exterior Wall 2x6 Front 270 1 48 0.3 NFRC 0.2 NFRC Bug Screen (3) Window 4620 FX Window Top Exterior Wall 2x6 Front 270 1 27 0.3 NFRC 0.2 NFRC Bug Screen Door 15080 SLD Window Top Exterior Wall 2x6 Front 270 1 120 0.3 NFRC 0.2 NFRC Bug Screen Door 2680 FR Window Top Exterior Wall 2x6 Front 270 1 20 0.3 NFRC 0.2 NFRC Bug Screen (2) Window 2040 SH Window Right Exterior Wall 2x6 Left 0 1 16 0.3 NFRC 0.2 NFRC Bug Screen Door 10080 SLD Window Right Exterior Wall 2x6 Left 0 1 80 0.3 NFRC 0.2 NFRC Bug Screen (3) Window 5060 SL Window Bottom Exterior Wall 2x6 Back 90 1 90 0.3 NFRC 0.2 NFRC Bug Screen Window 2020 FX Window Bottom Exterior Wall 2x6 Back 90 1 4 0.3 NFRC 0.2 NFRC Bug Screen Window 5060 SL Window Left Exterior Wall 2x6 Right 180 1 30 0.3 NFRC 0.2 NFRC Bug Screen Window 4016 SL Window Left Exterior Wall 2x6 Right 180 1 6 0.3 NFRC 0.2 NFRC Bug Screen Window 6050 SL 2 Window Left Exterior Wall 2x6 Right 180 1 30 0.3 NFRC 0.2 NFRC Bug Screen Window 2650 SH Window Left Exterior Wall 2x6 Right 180 1 13 0.3 NFRC 0.2 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor 3680 SC DR Bottom Exterior Wall 2x6 28 0.2 Door 16080 Bottom Exterior Garage 128 1 Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-12-02 10:27:47 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 6 of 11) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 8080 Bottom Exterior Garage 64 1 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab -on -Grade Floor Plan 3365 275 none 0 80% No Slab -on -Grade 2 Garage 693 69 none 0 0% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C. R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / R-4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco R-15 Garage Surface Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C. R-15 None / None 0.086 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Other Side Finish: Gypsum Board Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-12-02 10:27:47 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 7 of 11) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C. R-0 None / None 0.4 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofFloor Plan Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C. R-19 None / None 0.055 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around RoofJoists: R-6.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. 0. C. R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-38 Roof Attic + R19 Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (1) n/a None n/a Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-12-02 10:27:47 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 8 of 11) WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous 1 0 0.97-UEF <= 200 kBtu/hr 0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count 3.5T1 Heat pump heating cooling Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 2 2 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 1 Central split HP 2 8.5 41000 28700 16 13 Not Zonal Single Speed Heat Pump System 1-hers-htpump Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-12-02 10:27:47 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 9 of 11) HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Verified HSPF Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Required Required Yes Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return BypassDuct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non -Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: 2021-12-02 11:08:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-12-02 10:27:47 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 10 of 11) HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 126 0.25 Default 0 n/a Registration Number: CaICERiz,,-NA HERS Lit 221-P010250017A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2021-12-02 11:08:21 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-12-02 10:27:47 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 50695 Calle Guaymas Calculation Description: Title 24 Analysis Calculation Date/Time: 2021-12-02T10:26:55-08:00 Input File Name: 65758_Lot 41.ribdl9x CF1R-PRF-01E (Page 11 of 11) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Ly Ngo Documentation Author Signature: 4,4' Company: Gouvis Engineering Consulting Group Signature Date: 2021-12-02 10:53:09 Address: 15 Studebaker CEA/ HERS Certification Identification (If applicable): City/State/Zip: Irvine, CA 92618 Phone: 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Ken Niemerski Responsible Designer Signature: ieedv/Ufewe '�v Company: Bassenian Lagoni Date Signed: 2021-12-02 11:08:21 Address: 2031 Orchard Drive License: C23971 City/State/Zip: Newport Beach, CA 92660 Phone: 949-553-9100 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 221-P010250017A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2021-12-02 11:08:21 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-12-02 10:27:47 Schema Version: rev 20200901