BPOL2022-0200Permit Details City of La Quinta Description: COURTNEY / POOL AND SPA AT REAR YARD Type: POOL CONSTRUCTION Subtype: PRIVATE Status: FINALED (WEB) Applied: 5/18/2022 ECON Approved: 6/30/2022 AOR Issued: 7/5/2022 AMA Finaled: 11/30/2022 BBL Expired: Parcel No: 646182015 Site Address: 78461 CALLE HUERTA LA QUINTA,CA 92253 Subdivision: TR 3448 Block: Lot: 37 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Valuation: $28,000.00 Occupancy Type: Construction Type: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: POOL AND SPA AT REAR YARD [JHA ENGINEERING] TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ON SITE FOR INSPECTION. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. Process Summary 1413 5 43 Applied to Approved Approved to Issued _] Issued to Finaled CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AJ ORTEGA 6/24/2022 6/24/2022 EMAILED APPLICANT (williamspoolspecialist@gmail.com) 2ND REVIEW CORRECTIONS. E-MAIL JULIO ANAYA 6/13/2022 6/13/2022 EMAILED APPLICANT REQUIRED CORRECTIONS CONDITIONS - CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT WILLIAMS POOL SPECIALIST 40972 AETNA SPRINGS STREET INDIO CA 92203 (760)777-7013 williamspoolspecialist @gmail.com CITY STAFF ARMANDO MAGALLON 78495 CALLE TAMPICO LA QUINTA CA 92253 (760)777-7013 AMAGALLON@LAQUIN TACA.GOV CONTRACTOR WILLIAMS POOL SPECIALIST 40972 AETNA SPRINGS STREET INDIO CA 92203 (760)777-7013 williamspoolspecialist @gmail.com Printed: Wednesday, July 10, 2024 5:40:55 PM 1 of 5 CRWSYSTEMS Permit Details PERMIT NUMBER City of La Quinta BPOL2022-0200 CONTACTS NAME TYPE NAME ADDRESS1 CITY I STATE I ZIP I PHONE I FAX I EMAIL OWNER JOHN COURTNEY 78461 CALLE HUERTA CT. LA QUINTA CA 92253 (760)777-7013 DESCRIPTION ACCOUNT QTY FINANCIAL INFORMATION PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY AMOUNT PAID BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 7/5/22 R71142 INVOICE 2044 CREDIT WILLIAM CABALLERO AMA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $2.00 SWIMMING POOL/SPA/WATER FEATURE 101-0000-42404 0 $208.41 $208.41 7/5/22 R71142 INVOICE 2044 CREDIT WILLIAM CABALLERO AMA SWIMMING POOL/SPA/WATER FEATURE PC 101-0000-42600 0 $113.38 $113.38 7/5/22 R71142 INVOICE 2044 CREDIT WILLIAM CABALLERO AMA Total Paid for POOL / SPA 2021: $321.79 $321.79 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 7/5/22 R71142 INVOICE 2044 CREDIT WILLIAM CABALLERO AMA Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/5/22 R71142 INVOICE 2044 CREDIT WILLIAM CABALLERO AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 ilk TOTA339.79 $339.79 INSPECTION SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES Printed: Wednesday, July 10, 2024 5:40:55 PM 2 of 5 CRWSYSTEMS Permit Details PERMIT NUMBER City of La Quints BPOL2022-020 PRE-GUNITE BBL 7/26/2022 7/26/2022 APPROVED W/EXCEPTIO N Plumbing from pool to equipment under test and approved.Electrical conduit from pool to equipment to service approvedFour points of bonding noted.Pre-Gunite is approved once a small portion of sluff has been removed from the side of the pool and providing additional clearance for plumbing lines to soil at spa. DECK BOND BBL 8/5/2022 8/5/2022 APPROVED Deck bond is approved. PRE -PLASTER BBL 9/23/2022 9/23/2022 DISAPPROVE D Enclosure and gates are not installed at this time.Noted hall door safety devices on all doors. PRE -PLASTER BBL 9/30/2022 9/30/2022 APPROVED Pre -plaster is approved. UNDERGROUND PLBG BBL 10/14/2022 10/14/2022 APPROVED Approved on inspection on 7/26/2022. UNDERGROUND ELEC BBL 10/14/2022 10/14/2022 APPROVED Approved on inspection on 7/26/2022. FINAL** BBL 10/14/2022 10/14/2022 DISAPPROVE D A dead front cover has been altered to expose pipe and wires. Secure opening a dead front cover no wires to pass at this point.Provide solar blankets for pool spa. FINAL** BBL 10/24/2022 10/24/2022 DISAPPROVE D Expose transition from 1 inch PVC to three- quarter inch PVC which is currently buried underground.Service panel:lnstall KO seal in bottom of panel and properly secure it.Dead front cover needs to be sealed off where opening was cut into the metal. Ensure no sharp edges on dead front. FINAL** BBL 11/30/2022 11/30/2022 APPROVED Permit is final. PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE I RE DATEED STATUS REMARKS Printed: Wednesday, July 10, 2024 5:40:55 PM 3 of 5 CRWSYSTEMS 1ST BLDG NS ETRAKIT (1 DAY) JULIO ANAYA 5/18/2022 5/19/2022 6/13/2022 REVISIONS REQUIRED REFERENCE TO 1ST REVIEW REDLINE SITE PLAN 1ST PLANNING (1 WK) CARLOS FLORES 5/31/2022 6/7/2022 6/6/2022 READY FOR APPROVAL 2ND BLDG NS — ETRAKIT (1 DAY) Al ORTEGA 6/23/2022 6/24/2022 6/24/2022 REVISIONS REQUIRED UPDATE SITE PLAN PER STREET IMPROVEMENT PLAN TO ACCURATELY PROPERTY LINES AND ASSOCIATED SETBACKS, THEN BASED ON EQUIPMENT SCREENING REQUIREMENTS OF LQMC 9.60.140(6)(2) FURTHER PLANNING REVIEW IS REQUIRED — SEE 2ND REVIEW PLAN SET MARKUP ATTACHED. 3RD BLDG NS — ETRAKIT (1 DAY) AJ ORTEGA 6/30/2022 7/1/2022 6/30/2022 APPROVED BOND INFORMATION ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/24/2022 AJ ORTEGA 2ND REVIEW SITE PLAN MARKUP BPOL2022 0200 2ND REVIEW SITE PLAN MARKUP.pdf 0 DOC 6/30/2022 AJ ORTEGA SITE PLAN (APPROVED) BPOL2022 0200 SITE PLAN (APPROVED).pdf 1 DOC 5/18/2022 Etrakit Contractor POOL PLANS 78461 Calle Huerta Ct LQ 002_002.pdf 0 DOC 5/18/2022 Etrakit Contractor POOL ENGINEERING (FOR REFERENCE ONLY) BPOL2022-0200 - POOL ENGINEERING (FOR REFERENCE ONLY).pdf 1 DOC 6/23/2022 Etrakit Contractor 78461 Calle Huerta Ct LQ Revised with corrections.pdf 0 DOC 6/30/2022 Etrakit Contractor 78461 Calle Huerta Ct LQ Revised with corrections0l.pdf 0 Printed: Wednesday, July 10, 2024 5:40:55 PM 4 of 5 CRWSYSTEMS Permit Details City of La Quinta ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 7/1/2022 Etrakit Contractor HOA APPROVAL BPOL2022-0200 - HOA APPROVAL.pdf 1 DOC 6/13/2022 JULIO ANAYA 1ST REVIEW REDLINE SITE PLAN BPOL2022-0200 - 1ST REVIEW REDLINE SITE PLAN.pdf 0 Printed: Wednesday, July 10, 2024 5:40:55 PM 5 of 5 CRWSYSTEMS Casitas 1 at Montero Estates Professionally Managed by: PERSONALIZED PROPERTY MANAGEMENT PPNI The Coachella Valley's Cornmunicy Managemem Company July 1, 2022 Re: Pool Installation Architectural Approval To Whom It May Concern, 68950 Adelina Road Cathedral City, CA 92234 Phone: (760) 325-9500 Fax: (760) 325-9300 Ownership in a common interest development (CID) offers many advantages, but at the same time imposes a few restrictions. These guidelines are not meant to inconvenience or invade your freedom but rather to maintain harmony and aesthetic continuity within your community. The Board of Directors and the Architectural Committee appreciate your architectural application. We thank you for your patience while ensuring that the HOA Architectural Guidelines are followed. The Architectural Committee and the Board of Directors have approved the work as submitted on and as described below: Pool Installation approved as submitted. Pool water must be hooked up to homeowner's personal water bill, with proof of this connection submitted to board before installation. The following conditions apply: 1. Copies of all City Permits must be provided to the association. 2. The work must begin within 30 days of the date of this letter and completed within 60 days. Any later, and you must reapply for approval. 3. Please advise immediate neighbors as a courtesy of the project. 4. All contractors used must be appropriately licensed and insured. Thanking you in advance for your assistance in this matter and wishing you all the best in your exciting endeavor. Should you have any questions on this matter, please feel free to contact your Board of Directors or Community Manager David J. Schuknecht at Personalized Property Management Company at the address above or at David@PPMinternet.com Sincerely, Casitas 1 at Montero Estates Board of Directors PERSONALIZED PROPERTY MANAGEMENT I CPcCe J { C inirnMOdhy ArapkwPRI tt �• HOMEOWNERS ASSOCIATION ARCHITECTURAL APPLICATION C/O PERSONALIZED PROPERTY MANAGEMENT GENERAL INFORMATION: Homeowner's name• 605162 Saskatchewan Ltd 760-325-9500 �FFCE 766J325-9300 rAx E8950Adalire I CL d CELh8 dJJ City, CA J2231. www.PPHintarnaLcorn Property address: 78 461 Calle huerta, La Quinta Mailing address: 78 780 Rio Seco La Quint CA 92253 Phone: 306-221-5920 Work start date: May 15 2022 Estimated completion date: Aug 30 2022 Contractor License #1070209 BRIEF DESCRIPTION OF IMPROVEMENT: NOTE: TO AVOID DELAYS, PLEASE ATTACH AS MANY ADDITIONAL PAGES AS NEEDED TO 1, PROPERLY DESCRIBE THE IMPROVEMENTS TO THE ARCHITECHURAL COMMITTEE, INCLUDING PLANS, SKETCHES AND OR DIAGRAMS SHOWING ALL COLORS, DIMENSIONS, MATERIALS, LOCATION ON THE LOT ETC. IMPORTANT: ARC APPROVAL IN NO WAY RELIEVES THE HOMEOWNER OF THE RESPONSIBILITY FOR PROPER DRAINAGE AND OR PROPER PERMITS. Please see the attached plan for a new pool in the backyard at our house. THIS SPACE FOR ARCHITECHURAL COMMITTEE USE ONLY The application has been assigned ARC file number APPROVED (Subject to compliance with Association's CC&R's and By -Laws and approval by all applicable local, state and federal agencies). DISAPPROVED AS SUBMITTED FOR THE FOLLOWING - - REASONS: Signature of ARC Member: Date: NNVENNANCE I ACCOUNTING SERVICE I CONSlltflSi I REAL E TATE Signature of Applicants: PERSONALIZED PROPERTY MANAGEMENT I CPcCe J { C inirn tdhy ArapkwPRI tt �• 760-325-9500 �FFCE 760- 325-9300 rAx E8950Adalire I CL d CELh8dJJ City, CA •J2231. www.PPHlntarnaLcorn Date: April 29, 2022 Date: THIS SPACE FOR ARGHITECHURAL COMMITTEE USE ONLY The application has been assigned ARC file number APPROVED (Subject to compliance with Association's CC&R's and By -Laws and approval by all applicable local, state and federal agencies). DISAPPROVED AS SUBMITTED FOR THE FOLLOWING - - REASONS: Signature of ARC Member: Date: NNVENNANCE I ACCOUNTING SERVICE I CONSlltflSi I REAL E FATE 10ft Ficus Tree around the property line 0 / OWNER NAME: JOHN COURTNEY • Pool Fence 5" Removable Mesh Barrier 7' x 7' Raised Spa at +18 w/ Tile Spillways 6 Therapy Jets at Random Heights 6" Tile Waterline 3' of Brush Gray Concretearound Pool New Tanning Shelf 8'0" x 8'0" -9" W.D. with an Umbrella Sleeve 10ft Ficus Tree around the property line Brush Gray Concrete Pads r " - —Mk" - Alk AIIIbgllk Alk. alle 1011.11 Allitalt. lag" AA" 441111F-444EIRIPI 11,111"11119111,11PIMPIFIIPrilgr 1111"11.11.1111"111,1111,111,111111"1111,1111,11.1"."1" 11111"1.11.114V 1 1 401 110 410 411 1 Copper Bonding Grid Copper Bonding Grid 0 7' 0 \Q/ W.D. 1 Q 1 c �(.0 EGA 1 . 1 1 1 1 1 W.D. 30' \12/ W.D. LED Pool Lights \I • • #8 Equipotential Bonding Grid To Be Installed Digging Access Split Main Drains 3' Apart with Anti -vortex 10" ASME/ANSI loft Ficus Tree around the property line Copper Bondin' 1 1 1 1 1• 0 • ♦ Copper Bonding Grid Brand Techko Maid Includes Two Pairs of Magnetic Contact Sensors and a Remote Bypass Button Item Safe Pool Alarm Noise 100-115 dB StandardsApprovals ETL Approved Under UL 2017 Listed 5" Removable Mesh Self Latching/Closing Door Barrier Revised Property Line Gates Shall Be Self -Closing and Self Latching. And Shall Swing Outward Away From Pool/Spa 411 411 — N r • • • • • • i Techko-Safety Pool Model S187D Door Alarm (Door Alarm To Be Used In All Doors Going Out To Pool Area) RESIDENCE MIN M1• EMIR BPOL2022-0200 CI TY CF LA QU N TA BULONGDVI9ON REVI EYED FOR COCE COWL! AN CE BY A. LV. as ME: 0613012022 POOL AND SPA AT REAR YARD [JHA ENGINEERING] TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ON SITE FOR INSPECTION. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. 5' 8" Skimmer End Autofill Brush Gray Concrete Pads 5" Removable Mesh Self Latching/Closing Door Barrier 7' 8" 5'10"—' Proposed Pool Equipment Location Pool Equipment will be at 7'8" to P/L and 3'6 to Metal fence within P/L that could be remove if necessary 8' Ficus to be sc-eening wall for pool pool equipment 40AN P Pool Sub -Panel Revised Property Line 42 LF of 1" Electrical Conduit from Main Panel to Equipment Panel 49 LF of 2" Poly-Ethelene Gas Line w/ 10 AWG Yellow Tracer CALLE H U E RTA CT. Existing 200AMP Main Electrical Pa iel 13' 6" Gas Meter MONTERO 13'6" to curbside Scale: 7/32" = 1 ft 0 2 4 6 8 10 Address: 78461 CALLE HUERTA CT. CITY: LA QUINTA ST: CA ZIP: 92253 POOL SPECS SIZE: 14' X 30' AREA: 372 SQ FT. DEPTH: 3'6" X 5'6" SKIMMER: 1 RETURNS: 3 TILE:TBD PERIMETER: 92 FT. GAL: 10123 SPA SPECS SIZE: 7' X 7' AREA: 49 SQ FT. DEPTH: 3'6" JETS: 6 HEIGHT: +18" TILE:TBD PERIMETER:28 FT. GAL: 577 PLUMBING RETURNS: 3 SKIMMER: 1 POOL MAIN DRAIN: 2 VAC LINE: 1 WATER FEATURE :1 PVC: 2" SCHEDULE 40 GAS LINE:POLY PIPE 1.5" SPA LIGHT :1 COLOR LED LIGHT POOL LIGHT : 2 COLOR LED LIGHT DECK DECK TYPE :BRUSH GRAY CONCRETE RAISE POST : +18" CONCRETE AREA:TBD TANNINGV SHELF DEPTH: -9" TANNING SHELF : 8' X 8' POOL E • UIPMENT 1- PENTAIR VSF FILTER PUMP 1- PENTAIR MASTERTEMP 300,000 BTU HEATER 1- PENTAIR CLEAN & CLEAR 320 SQ. FT. FILTER 2- PENTAIR LED COLOR POOL LIGHTS 1- PENTAIR LED COLOR SPA LIGHT PENTAIR EASYTOUCH LITE 4 FUCTION REMOTE CONTROL WILLIAMS POOL SPECIALIST NOTES : 1. ALL EQUIPMENT WILL BE SEISMICALLY ANCHORED 2. ALL GFI OUTLETS WILL BE WEATHER AND TAMPER PROOF 3. ALL OUTLETS SUPPLIED BY SINGLE PHASE. 15A AND 20A . 125V OR 240V BRANCH CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION 4. PROVIDE 36" WORKING CLEARANCE FOR POOL EQUIPMENT MOTORS 5. POOL SAFETY BARRIERS FLOATING ALARMS BUBBLE POOL COVER EXIT DOORS ALARMS SELF CLOSING SELF LATCHING DOORS 6. POOL AND SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART ANTI -COVERS 10" ASME/ANSI APPROVED SPA TO BE EQUIPPED WITH ANTI -ENTRAPMENT DEVICE (SEC.1404 FEDERAL SWIMMING POOL AND SPA DRAIN COVER STANDARD) PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT STANDARS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS(ASTM) OR THE AMERICAN SOCIETY MECHANICAL ENGINEERS( ASME) IDENTIFY A MINIMUN 3 FEET SEPARATION BETWEEN ALL DRAINS AND NOTE HYDRAULICALLY BALANCED SAFETY FEATURES: ALL ANTI-ETRAPMENT COVER INSTALLATION MEETING CURRENT STANDARD OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGENEERS(ASME) ELECTRICAL : EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELLIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26 BUILDING CODES: 2019 California Residential 2019 California Electrical Code 2019 California Mechanical 2019 California Plumbing Code 2019 California Green Code 2019 California Energy Code Based on 2015 International Residential Code (IRC) Based on 2014 National Electrical Code (NEC) Based on 2015 Uniform Mechanical Code (UMC) Based on 2015 Uniform Plumbing Code (UPC) California Building Standard Commission California Energy Commission INSTALLATION OF THE POOL SYSTEM AND EQUIPMENT WILL COMPLY WITH SECTION 114- MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATER, POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURES RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS 1