BSOL 2023-0207BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Solar
Permit Number:
BSOL2023-0207
Property Address:
81920 VIVACE CT
APN:
764470041
Legal Description
Property Zoning:
Valuation:
$11,257.00
PHONE (760) 777-7125
�� WWW.LAQUINTACA.GOV
APPLIED DATE: 07/17/2023
eca QISSUED DATE: 11/17/2023
CALIFORNIA
Owner: Richmond American Homes of Maryland Inc
5171 CALIFORNIA AVE STE 120, IRVINE, CA 9261'
Applicant: Ivan Garcia
775 FIERO LANE SUITE 200, SAN LUIS OBISPO,
CA 93401
Contractor: Ivan Garcia / 750184
775 FIERO LANE SUITE 200, SAN LUIS OBISPO,
CA 93401
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 7/24/24 12:03 pm Page 1 of 4
1-311111]1!"a4 NV,IkI
Permit Type: Solar
Permit Number: BSOL2023-0207
Property Address: 81920 VIVACE CT
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
Printed: 7/24/24 12:03 pm Page 2 of 4
Permit Type: Solar
11111I14111►Ma4MYilIII I
Permit Number
Property Address
BSOL2023-0207
81920 VIVACE CT
BELLA AT PIAZZA SERENA/ 5.925kW SOLAR ARRAY - (15) JA SOLAR JAM54S31-395/MR +(15) ENPHASE ENERGY IQ7PLUS-72-2-US +
80A IQ COMBINER 3C [315SF]. LOT63 / REFERENCE BCPR2022-0005 FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING
CODES.
System Size (kW DC) 5.925 PV Strings (EA) 1
I Type Group Sq Ft Value I
Invoice No. Fee
INV-00002478 PERMIT ISSUANCE
Credit Card Convenience Fee
PV SYSTEM LESS THAN 10KW
RECORDS MANAGEMENT FEE
PV SYSTEM LESS THAN 10KW PC
BSAS SB1473 FEE
TECHNOLOGY ENHANCEMENT FEE
Workflow Step / Action Name
Application Completeness Check v.1
..................
Fee Amount
Amount Paid
$110.88
$110.88
$4.73
$4.73
$29.18
$29.18
$11.00
$11.00
$29.18
$29.18
$1.00
$1.00
$8.00
$8.00
Total for Invoice INV-00002478 $193.97
$193.97
Grand Total for Permit
Action Type
Generic Action
Receive Submittal
Generic Action
Generic Action
Generic Action
Create Report
Inspection
Inspection
Inspection
Inspection
$193.97
$193.97
Start Date
End Date
11/17/2023
8:59
.........
11/17/2023
8:59
11/17/2023
8:59
11/17/2023
8:59
11/17/2023 9:00
11/17/2023
9:41
11/17/2023
9:00
11/17/2023
9:00
11/17/2023
9:41
11/17/2023 9:41
11/17/2023
9:41
12/11/2023 0:00 12/13/2023 13:54
12/11/2023 0:00 12/13/2023 13:54
Printed: 7/24/24 12:03 pm Page 3 of 4
1-311111111]1Z"a4 N IT, lIII I
Permit Type: Solar
Permit Number: BSOL2023-0207
Property Address: 81920 VIVACE CT
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
iurisdiction shall not be valid.
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Printed: 7/24/24 12:03 pm Page 4 of 4
ARRAY
TRUE
PV AREA
PITCH
AZIM
(SQFT)
AR-01
18'
147'
126.1
AR-02
18'
147'
189.2
LEGEND
R
MAIN PANEL
AC
0
AC DISCONNECT
CB
IQ COMBINER BOX
1'
3'
L I
INTERIOR EQUIPMENT
18' 11" NOTES:
\
SHOWN AS DASHED
• RESIDENCE CONTAINS ACTIVE FIRE SPRINKLERS.
� 11'-5"
\ ARRAY DETAILS:
FIRE SETBACKS
• TOTAL ROOF SURFACE AREA: 2000 SQFT.
• TOTAL PV ARRAY AREA: 315.3 SQ FT.
CB PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AC
AREA) * 100 = 15.8%
15'-2"
4'
TYP
MP
0
PV SYSTEM SHALL NOT OBSTRUCT OR
INTERFERE WITH THE FUNCTION OF VENTS
OR MECHANICAL EQUIPMENT; MIN 6"
SEPARATION REQUIRED (CMC 304.1, CPC 906,
/6-2
SPG PART 5 SECT. 8), OR ENGINEER DESIGN
IS REQUIRED (CPC 301.5).
• SYSTEM SIZE: 5925W DC, 4350W AC
• MODULES: (15) JA SOLAR: JAM54S31-395/MR
• INVERTER(S):
(15) ENPHASE ENERGY: IQ7PLUS-72-2-US
• RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE
WITH STANDOFF TO RAFTER: SNR-DC-01249
LOT PLAN ELEVATION
63 S853 B
ROOF TYPE
CONCRETE TILE [FLAT]
SYSTEM SIZE I MODULES
5.925KW 1 15
sunrun
GILBERT CORREIA, C10, C46
CA CL #750184
1550 MAGNOLIA AVE, CORONA, CA 92879
PHONE 805.540.7603
FAX 949.215.7778
CUSTOMER RESIDENCE:
RICHMOND AMERICAN HOMES
BUILDER
81-920 VIVACE COURT, LA
QUINTA, CA, 92253
TEL. 8882361589
APN #: APN:
PROJECT NUMBER:
126R-920BU13
DESIGNER: (415) 580-6920 ex3
GABRIEL DALAY TIMAJO
SHEET
SITE PLAN
REV: A
SITE PLAN - SCALE = 3/32" = V-0" PAGE
PV-2.0
6/14/2023
Microinverter: Enphase
IQ7PLUS-72-2-US
(Mounted to the back of each module)
PV Circuit 1:
8 JA SOLAR 1 2
JAM54S31-395/MR ...
PV Modules /
Parallel L—J
PV Circuit 2: 1 2 7
7 JA SOLAR
JAM54S31-395/MR •.� 1
PV Modules /
Parallel NEMA 311 Junction Box
2 POLE
Photovoltaic System
System Size (Watts) 5925
C System Size (Watts) 4350
Total Module Count 15
MODULE CHARACTERISTICS
[•iQNCt•ZUd
JA SOLAR: JAM54S31-395/MR:
395 W
OPEN CIRCUIT VOLTAGE:
36.98 V
MAX POWER VOLTAGE:
30.84 V
SHORT CIRCUIT CURRENT:
13.7 A
V I 6
BOND COLD WATER AND GAS LINES TO
GROUNDING ELECTRODE CONDUCTOR PER
[CEC 250.105(A)&(B)].
POP RIVETS OR SCREWS ARE NOT ALLOWED
FOR ATTACHMENT OF PLACARDS TO THE
MAIN SERVICE PANEL. (AS PER AHJ)
Point of Interconnection, Load Side
705.12(B)(2)(1)(b)
Existing 240V/200A
MIN. Service Panel,
Single Phase, with 200A
Main Disconnect
20A 15A
2oA M
2 POLE
Square D DU221RB, 200A
240V/30A, Unfused,
NEMA3R
3 3 3
25A
Combiner Panel Enphase IQ Combiner X IQ
AM1-240-3 64A/240V Continuous, protection
max 80A breaker on solar output; with 10 KAIC I t
circuit breakers
Visible/Lockable'Knife' 'WFACIUTYGROUND
AC Disconnect
Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)
CONDUCTOR NEUTRAL GROUND CONDUIT
(2)12 AWG PV WIRE NONE (1)6AWG BARE COPPER NONE
(2)10 AWG NM NONE (1)10 AWG NM 3/4"NM-B
(2)10 AWG NM (1)10 AWG NM (1)8 AWG NM 3/4"NM-B
Conduit Conductor Schedule (Unless Otherwise
Specified Conductors Shall be Copper)
TAG
CONDUCTOR
NEUTRAL
GROUND
CONDUIT
1
(2) 10 AWGPV WIRE
No
(1)6 AWG BARE COPPER
NONE
2
(2)10 AWG THHN-THWN-2
NONE
1 (1) 1GAWG THHN/THWN-2
314" EMT OR EQUIVALENT
3
(2)10 AWG THHN-THWN-2
1 (1) 10 AWG THHN/THWN-2
I (1)8AWGTHHN/THWN-2 1
3/4" EMT OR EQUIVALENT
'DEPENDING ON INVENTORY AT
TIME OF INSTALL'
GENERAL NOTES:
• VERIFY EXISTING FACILITY GROUNDING ELECTRODES ARE COMPLIANT WITH
250.52 AND 250.53.
IF NO FEASIBLE GROUNDING IS AVAILABLE, TWO STAINLESS STEEL AND
COPPER OR ZINC COATED STEEL GROUND RODS (5/8" X 8FT) TO BE INSTALLED
AT MINIMUM 6' APART WITH 8' MINIMUM EMBEDMENT TO GROUND COMPLIANT
WITH 250.52 AND 250.53.
• AFCI PROTECTION IS NEEDED WHEN LOADS ARE RELOCATED MORE THAN 6'
FROM THEIR INITIAL LOCATION PER 210.12 (D).
6-12 AWG BARE
COPPER WIRE
SS BONDING
PINS -
-111 —11.,OLT
;K WASHER
16 FT-LBS)
SNAPNRACK
GROUND LUG
Builder to Ensure
SPD Compliance
(230.67)
sun,run
/v
GILBERT CORREIA, C10, C46
CA CL #750184
1550 MAGNOLIA AVE, CORONA, CA 92879
PHONE 805.540.7603
FAX 949.215.7778
CUSTOMER RESIDENCE:
RICHMOND AMERICAN HOMES
BUILDER
81-920 VIVACE COURT, LA
QUINTA, CA, 92253
TEL. 8882361589
APN #: APN:
BONDING I PROJECT NUMBER:
CHANNEL NUT 126R-920BU13
RAIL
NOTE:
• ALL HARDWARE IS INCLUDED FROM MANUFACTURER
• A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY
CONTINUOUS ROW OF MODULES
• GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL
• GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS
PARALLEL OR PERPENDICULAR TO RAIL
• ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER
WIRE
SNAPNRACK GROUNDING SCALE: NTS
DESIGNER: (415) 580-6920 ex3
GABRIEL DALAY TIMAJO
SHEET
ELECTRICAL
REV: A 6/14/2023 1
PAGE PV-4.0
CAUTION
POWER TO THIS BUILDING IS
ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH
DISCONNECTS AS SHOWN
SOLAR PANELS AND MICRO
INVERTERS ON ROOF
COMBINER PANEL
MAIN PANEL & AC
DISCONNECT
81-920 VIVACE COURT, LA QUINTA, CA, 92253
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION.
PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC
2011: 690.54
MODULE CHARACTERISTICS
JA SOLAR: JAM54S31-395/MR
395 W
OPEN CIRCUIT VOLTAGE
36.98 V
MAX POWER VOLTAGE
30.84 V
SHORT CIRCUIT CURRENT
13.7 A
INVERTER CHARACTERISTICS - ENPHASE
RATED OUTPUT POWER
240 W
SYSTEM OPERATING VOLTAGE
240 V
MAX ALLOWABLE DC VOLTAGE
0 V
SYSTEM OPERATING CURRENT
1.0 A
SYSTEM SHORT CIRCUIT CURRENT
15 A
PER CODE: 690.52
LABELING FORMAT
RICHMOND AMERICAN HOMES BUILDER LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS
(126R-920BU13) MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR
81-920 VIVACE COURT, LA QUINTA, CA, THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE.
92253