Loading...
BPOL2021-0152BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 05/08/2021 ISSUED DATE: 06/23/2021 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 54430 AVENIDA OBREGON BPOL2021-0152 774242008 $10,000.00 Owner:MAKINO CATHERINE 54430 AVENIDA OBREGON, LA QUINTA, CA 92253 Applicant:TESERRA TESERRA 38822 El Desierto Rd P O BOX 1280, Palm Desert, CA 92211 Contractor:TESERRA TESERRA / 656128 38822 El Desierto Rd P O BOX 1280, Palm Desert, CA 92211 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 8/13/24 3:52 pm Page 1 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2021-0152 54430 AVENIDA OBREGON BUILDING PERMIT application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 8/13/24 3:52 pm Page 2 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2021-0152 54430 AVENIDA OBREGON BUILDING PERMIT MAKINO / POOL AND 92LF OF GARDEN WALL AT FRONT YARD *** POOL AND 92LF OF 5’& 6’H BLOCK WALL AT FRONT YARD [PATRELL ENGINEERING] APPROVED PLAN AND WET SIGNED ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA BUILDING CODES. #|||# MAKINO / POOL AND 92LF OF GARDEN WALL AT FRONT YARD *** REVISION 1 - DELTA 4 ONLY: ADDED 9LF OF 5' HIGH BLOCK WALL TO SCOPE OF WORK. Use of Permit Construction Details 92Total Wall Length (Linear Footage) Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BPOL2021-015 2 $5.00 TECHNOLOGY ENHANCEMENT FEE $5.00 $109.48 SWIMMING POOL/SPA PC $109.48 $1.00 BSAS SB1473 FEE $1.00 $41.75 HOURLY CHARGE - CITY BUILDING STAFF $41.75 $16.67 WALL/FENCE - EA ADDITIONAL 50LF $16.67 $10.00 RECORDS MANAGEMENT FEE $10.00 $67.08 WALL/FENCE - FIRST 100LF PC $67.08 $53.67 WALL/FENCE - FIRST 100LF $53.67 $201.25 SWIMMING POOL/SPA $201.25 $505.90 $505.90 Total for Invoice PERMIT-BPOL2021-0152 Grand Total for Permit $505.90 $505.90 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 05/08/2021 0:00 FINAL** v.1 Inspection BOND BEAM v.3 Inspection FOOTINGS v.4 Inspection FOOTINGS v.3 Inspection PRE-PLASTER v.1 Inspection DECK BOND v.2 Inspection BOND BEAM v.2 Inspection DECK BOND v.1 Inspection BOND BEAM v.1 Inspection FOOTINGS v.2 Inspection FOOTINGS v.1 Inspection UNDERGROUND ELEC v.1 Inspection Printed: 8/13/24 3:52 pm Page 3 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2021-0152 54430 AVENIDA OBREGON BUILDING PERMIT UNDERGROUND PLBG v.1 Inspection PRE-GUNITE v.1 Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 8/13/24 3:52 pm Page 4 of 4 Builders of Exceptional Outdoor Living13'-6"SB.10'5'SB.3'SB.5'-0" WD 3'-6" WD PBT JA S0" 0" PL PL EXISTING CONCRETE TO REMAIN 11'-9"SB. WS 23'12'SB.PL 50'SB.94'-5"SB.PL94'-5"SB.3'-3"SB. P R O P A N EGASADV ADV ADV ADV ADV ADV ADV ADV ADV 12'-6"SB.PB GUNITE 23'-0"10'-0" 230 SQ.FT. 66 LN.FT. N/A 3'-6"5'-0" SEE NOTES 60" BOBCAT FRONTYARD JANDY PRO SERIES 460 SQ.FT. JANDY 2.7HP VARIABLE MANUAL JANDY TRUE CLEAR DUAL PORT MP PRODUCTS AUTOFILL F.M. 2 1/2" SUCTION & 2 1/2" RETURN PAVERS ( 2 ) JANDY HYDROCOOL LED 3'X5' HIGH YES PAVER AS NECESSARY ( 2 ) JANDY HYDROCOOL LED RACK YES 86-100 AVE. 54 COACHELLA CA 92236PH: (760) 398-9222 FAX: (760) 398-9255CA LICENSE No. 656128SPECIFICATIONS A CUSTOM PROJECT FOR: REVISIONS DATE: 123456 SELECTIONS CONSTRUCTION AUTHORIZATION decking excavation / steel spa specifications plumbing gunite owner responsibilities masonry pebble / plaster fencing MISCELLANEOUS NAME COMMUNITY JOB ADDRESS CITY HOMEOWNER MOBILE PROJECT MANAGER MOBILE DATE DESIGNED BY PROJECT MGR.CHECKED BYSCALE MB # 18"=1' GROUT TILE POTS/BOWLS PEBB/PLAS BOULDERS DRAINAGE NOTE: DIG PRE-GUNITE UNDERGROUND MASONRY DECK PRE-PEBBLE SALES FIELD SIGNATURE(S)DATE (1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION. (2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA. (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO PREPLASTER INSPECTION. (6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS -- DO NOT USE RUBBER HOSE ) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. OWNER TO: SIZE SURFACE AREA OF POOL ONLY PERIMETER DEPTHS MIN.MAX X SIZE X SQ. FT. SPA DAM WALL WIDTH NO. OF JETS LIGHT RAISED SPA AT SPILLWAY TYPE SPECIAL NOTES GLASS TILE WATERLINE R.B.B. TILE TYPE ACCESS FROM ELEVATION DEEP END RAMP LOVE SEAT CONCRETE REMOVAL SOD REMOVAL TREE REMOVAL BY LOADS LOADS IRRIGATION REMOVAL BY IRRIGATION REPAIR FT. TAN SHELF DEPTH ROCK POCKETS CENTERS FILTER SIZE POOL PUMP BOOSTER PUMP ADDL PUMP ADDL PUMP HEATER CONTROL SYSTEM CHLORINATOR WIRELESS CONTROL SKIMMER TYPE FILL LINE GAS LINE STUBS W.F. ATTACHED TO POOL OTHER W.F. LIGHTS IN POOL STUB SET EQUIPMENT DEEP END RAMP EXTEND 2nd STEP LOVESEAT COPING R.B.B. - SEE STEEL REMOVE & REHANG GATE REVERSAL GATE HEIGHT FENCE TYPE DEEP HEAT RETURNS ECLIPSE DRAINS EYE BALL FITTINGS LIGHTS SPA LIGHTS POOL SEAT WALLS EQUIP. WALLS RETAINING WALLS PLANTER WALL PROP. EXT. WALLS STEPS SPILLWAY TYPE SIZE R.B.B. FACING COPING TYPE MOW STRIP BANDS SAND AND VISQUEEN TILE BASE STEP FACE STEPS SLEEVES DRAINS DOUBLE CANTILEVER CANTILEVER EXPANSION JOINTS FINISH SQ. FT. TILE SIZE SIZE SIZE SIZE SIZE EST. START EST. COMPLETION 30" R.B.B. Drainage and irrigation for planters and pots, by others, unless otherwise noted. LN. FT. POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTATION ONLY, FIELD LAYOUT WILL VARY EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS * NO EXISTING LANDSCAPE LIGHTING IN REAR YARD * NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD 78 POOL & SPA COMBINED * PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY FT.24" R.B.B. FT.18" R.B.B. FT.12" R.B.B. FT.6" R.B.B. PLUMBING SIZE PROJECT MANAGER EMAIL TRIM TILE EQUIPOTENTIAL BONDING GRID WELDED WIRE MESH REBAR BARBECUE COUNTERTOP BARBECUE SAND SET PAVERS STUCCO PAINT Q360 INFLOOR MISTING SYSTEM TRELLIS LIGHTS IN SPA LIGHTS IN W.F. DEEP HEAT PACKAGE Q360 INFLOOR MISC. PAVERS CONCRETE HOMEOWNER EMAIL FIREPIT ANTI VORTEX ECLIPSE DRAINS ANTI VORTEX CUSTOMER NUMBER: DBX # ADDED MATERIAL SELECTIONS 07.12.21 NPT AZUL-GRN-GRANITO-AZUL DEL MAR 2019 california building code ( BASED ON 2018 IBC ) 2019 california mechanical code ( BASED ON 2018 UMC ) 2019 california electrical code ( BASED ON 2017 NEC ) 2019 california energy green code electrical: EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26. safety features: * ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) 2019 california plumbing code ( BASED ON 2018 UPC )TITLE 24, PART 5 GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED 2019 california residential code ( BASED ON 2018 IRC ) 2019 california energy code RESIDENCE AVENIDA OBREGON ELECTRIC CONDUIT POOL / SPA LIGHT JUNCTION BOX POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER POOL EQUIPMENT 50 AMP SUBPANEL WITH 36" CLEARANCE AT FRONT AND SIDE MAIN HOUSE 200 AMP ELECTRICAL PANEL INSTALL POOL EQUIPMENT 6"X8"X16"COLORED BLOCK WALL AT +60"WITH 3'X5' WROUGHT IRON SERVICE GATE OPENING (SEE WALL ENGINEERING BY ORCO ATTACHED) TRANSFORMER SAW CUT DEMO 36" CONCRETE DRIVEWAY FOR PLUMBING RUNS AND INSTALL PAVER DECKING POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED 12"X6" WIDE BELGARD BRICK PAVER CONCRETE CATALINA GRANA 3 PIECE LARGE PAVER DECKING SAND SET OVER 4" OF COMPACTED ROAD BASE AND 1" OF BEDDING SAND, POLYMERIC SAND GROUT, MUD SET PAVER SOLDIER COURSE INSTALL PROPERTY 6"X8"X16" TAN PRECISION BLOCK WALL AT +72" WITH 3'X6' ENTRANCE WROUGHT IRON GATE OPENING WITH MESH BACKING (SEE WALL ENGINEERING BY ORCO ATTACHED) 70 SQ. FT.POOL COPING 470 SQ. FT.PAVER DECKING UNDERGROUND SERVICE ALERT A PUBLIC SERVICE BY BEFORE YOU DIG TOLL FREE DIAL TWO WORKING DAYS BEFORE 1-800-227-2600 YOU DIG YES OTHERS YES DEMO EXISTING WALKWAY (56 SQ. FT.) AND REPLACE WITH PAVERS EXISTING GATE TO OPEN OUTWARDS SELF CLOSING + SELF LATCHING WATER METER SEWER PALM TREE REMOVAL BY OTHERS 12'-0" SB FROM FACE OF CURB STONE SCAPES AQUAL WHITE MINI BELGARD VICTORIAN 3-PIECE SMALL SEE SUPERINTENDENT 1 POOL EQUIPMENT: PROPANE HEATER *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED HEATER TO BE SET ON A RACK NEW LANDSCAPING TO SURROUND PROPANE TANK, LANDSCAPE BY HOMEOWNER PROPANE TANK INSTALLED BY SPECIALTY PROPANE COMPANY, GAS LINE FROM HEATER TO PROPANE TANK BY TESERRA, HOOKUPS BY PROPANE COMPANY 8' - 11 2" POLYPROPYLENE GAS PIPE 12'-6" SB FROM FACE OF CURB TO PROPANE TANK JANDY 400,000 BTU PROPANE ADDED PLANTER BED 10.05.21 3 adjusted pool and wall layout 09.01.21 EXISTING WOODEN FENCE 5'-0"HIGH EXTEND NEW 5'-0" HIGH MASONRY WALL 9' IN LENGTH EXTEND NEW MASONRY WALL TO 9'-0", ADD PAVERS SQFT.10.08.21 4 10/18/2021 REVISION 1 - DELTA 4 ONLY: 9LF OF 5' HIGH GARDEN WALL [CITY STANDARD] 2019 CALIFORNIA BUILDING CODES. BPOL2021-0152