BPOL2021-0152BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 05/08/2021
ISSUED DATE: 06/23/2021
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Pool
54430 AVENIDA OBREGON
BPOL2021-0152
774242008
$10,000.00
Owner:MAKINO CATHERINE
54430 AVENIDA OBREGON, LA QUINTA, CA 92253
Applicant:TESERRA TESERRA
38822 El Desierto Rd P O BOX 1280, Palm Desert,
CA 92211
Contractor:TESERRA TESERRA / 656128
38822 El Desierto Rd P O BOX 1280, Palm Desert,
CA 92211
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 8/13/24 3:52 pm Page 1 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2021-0152
54430 AVENIDA OBREGON
BUILDING PERMIT
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
Printed: 8/13/24 3:52 pm Page 2 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2021-0152
54430 AVENIDA OBREGON
BUILDING PERMIT
MAKINO / POOL AND 92LF OF GARDEN WALL AT FRONT YARD *** POOL AND 92LF OF 5’& 6’H BLOCK WALL AT FRONT YARD
[PATRELL ENGINEERING] APPROVED PLAN AND WET SIGNED ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. ALARMS AND
BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PRECISION CONCRETE BLOCK SHALL BE COVERED WITH
STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF
CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY
MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA BUILDING CODES. #|||# MAKINO / POOL AND 92LF OF GARDEN WALL AT
FRONT YARD *** REVISION 1 - DELTA 4 ONLY: ADDED 9LF OF 5' HIGH BLOCK WALL TO SCOPE OF WORK.
Use of Permit
Construction Details
92Total Wall Length
(Linear Footage)
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
PERMIT-BPOL2021-015
2
$5.00 TECHNOLOGY ENHANCEMENT FEE $5.00
$109.48 SWIMMING POOL/SPA PC $109.48
$1.00 BSAS SB1473 FEE $1.00
$41.75 HOURLY CHARGE - CITY BUILDING STAFF $41.75
$16.67 WALL/FENCE - EA ADDITIONAL 50LF $16.67
$10.00 RECORDS MANAGEMENT FEE $10.00
$67.08 WALL/FENCE - FIRST 100LF PC $67.08
$53.67 WALL/FENCE - FIRST 100LF $53.67
$201.25 SWIMMING POOL/SPA $201.25
$505.90 $505.90 Total for Invoice PERMIT-BPOL2021-0152
Grand Total for Permit $505.90 $505.90
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Inspections v.1 05/08/2021 0:00
FINAL** v.1 Inspection
BOND BEAM v.3 Inspection
FOOTINGS v.4 Inspection
FOOTINGS v.3 Inspection
PRE-PLASTER v.1 Inspection
DECK BOND v.2 Inspection
BOND BEAM v.2 Inspection
DECK BOND v.1 Inspection
BOND BEAM v.1 Inspection
FOOTINGS v.2 Inspection
FOOTINGS v.1 Inspection
UNDERGROUND ELEC v.1 Inspection
Printed: 8/13/24 3:52 pm Page 3 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2021-0152
54430 AVENIDA OBREGON
BUILDING PERMIT
UNDERGROUND PLBG v.1 Inspection
PRE-GUNITE v.1 Inspection
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 8/13/24 3:52 pm Page 4 of 4
Builders of Exceptional Outdoor Living13'-6"SB.10'5'SB.3'SB.5'-0" WD
3'-6" WD PBT
JA
S0"
0"
PL PL
EXISTING
CONCRETE
TO REMAIN
11'-9"SB.
WS 23'12'SB.PL
50'SB.94'-5"SB.PL94'-5"SB.3'-3"SB.
P
R
O
P
A
N
EGASADV
ADV
ADV
ADV
ADV
ADV ADV
ADV
ADV
12'-6"SB.PB
GUNITE 23'-0"10'-0"
230 SQ.FT.
66 LN.FT.
N/A
3'-6"5'-0"
SEE NOTES
60" BOBCAT
FRONTYARD
JANDY PRO SERIES 460 SQ.FT.
JANDY 2.7HP VARIABLE
MANUAL
JANDY TRUE CLEAR
DUAL PORT
MP PRODUCTS AUTOFILL
F.M.
2 1/2" SUCTION & 2 1/2" RETURN
PAVERS
( 2 ) JANDY HYDROCOOL LED
3'X5' HIGH
YES
PAVER
AS NECESSARY
( 2 ) JANDY HYDROCOOL LED
RACK
YES 86-100 AVE. 54 COACHELLA CA 92236PH: (760) 398-9222 FAX: (760) 398-9255CA LICENSE No. 656128SPECIFICATIONS
A CUSTOM PROJECT FOR:
REVISIONS DATE:
123456
SELECTIONS
CONSTRUCTION AUTHORIZATION
decking
excavation / steel
spa specifications
plumbing
gunite
owner responsibilities
masonry
pebble / plaster
fencing
MISCELLANEOUS
NAME
COMMUNITY
JOB ADDRESS CITY
HOMEOWNER MOBILE
PROJECT MANAGER MOBILE
DATE DESIGNED BY PROJECT MGR.CHECKED BYSCALE
MB #
18"=1'
GROUT
TILE
POTS/BOWLS
PEBB/PLAS
BOULDERS
DRAINAGE NOTE:
DIG
PRE-GUNITE
UNDERGROUND
MASONRY
DECK
PRE-PEBBLE
SALES FIELD
SIGNATURE(S)DATE
(1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION.
(2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF
LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT.
(3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED.
(4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS,
AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA.
(5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE
PRIOR TO PREPLASTER INSPECTION.
(6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS -- DO NOT USE RUBBER HOSE )
(7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT
WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW.
OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE.
OWNER TO:
SIZE
SURFACE AREA OF POOL ONLY
PERIMETER DEPTHS MIN.MAX
X
SIZE X SQ. FT.
SPA DAM WALL WIDTH
NO. OF JETS
LIGHT
RAISED SPA AT
SPILLWAY TYPE
SPECIAL NOTES
GLASS TILE
WATERLINE
R.B.B. TILE
TYPE
ACCESS FROM
ELEVATION
DEEP END RAMP
LOVE SEAT
CONCRETE REMOVAL
SOD REMOVAL
TREE REMOVAL BY
LOADS
LOADS
IRRIGATION REMOVAL BY
IRRIGATION REPAIR
FT.
TAN SHELF DEPTH
ROCK POCKETS
CENTERS
FILTER SIZE
POOL PUMP
BOOSTER PUMP
ADDL PUMP
ADDL PUMP
HEATER
CONTROL SYSTEM
CHLORINATOR
WIRELESS CONTROL
SKIMMER TYPE
FILL LINE
GAS LINE STUBS
W.F. ATTACHED TO POOL
OTHER W.F.
LIGHTS IN POOL
STUB SET EQUIPMENT
DEEP END RAMP
EXTEND 2nd STEP
LOVESEAT
COPING
R.B.B. - SEE STEEL
REMOVE & REHANG
GATE REVERSAL
GATE
HEIGHT
FENCE TYPE
DEEP HEAT RETURNS
ECLIPSE DRAINS
EYE BALL FITTINGS
LIGHTS SPA
LIGHTS POOL
SEAT WALLS
EQUIP. WALLS
RETAINING WALLS
PLANTER WALL
PROP. EXT. WALLS
STEPS
SPILLWAY TYPE SIZE
R.B.B. FACING
COPING TYPE
MOW STRIP
BANDS
SAND AND VISQUEEN
TILE BASE
STEP FACE
STEPS
SLEEVES
DRAINS
DOUBLE CANTILEVER
CANTILEVER
EXPANSION JOINTS
FINISH
SQ. FT.
TILE
SIZE
SIZE
SIZE
SIZE
SIZE
EST. START
EST. COMPLETION
30" R.B.B.
Drainage and irrigation for planters and pots, by others,
unless otherwise noted.
LN. FT.
POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS
ALL DECKING EXPANSION JOINTS FOR REPRESENTATION ONLY,
FIELD LAYOUT WILL VARY
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS
TO THE POOL
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH
SECTION 114 - MANDATORY REQUIREMENTS
* NO EXISTING LANDSCAPE LIGHTING IN REAR YARD
* NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD
78
POOL & SPA COMBINED
* PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY
FT.24" R.B.B.
FT.18" R.B.B.
FT.12" R.B.B.
FT.6" R.B.B.
PLUMBING SIZE
PROJECT MANAGER EMAIL
TRIM TILE
EQUIPOTENTIAL BONDING GRID
WELDED WIRE MESH
REBAR
BARBECUE COUNTERTOP
BARBECUE
SAND SET PAVERS
STUCCO
PAINT
Q360 INFLOOR
MISTING SYSTEM
TRELLIS
LIGHTS IN SPA
LIGHTS IN W.F.
DEEP HEAT PACKAGE
Q360 INFLOOR
MISC.
PAVERS
CONCRETE
HOMEOWNER EMAIL
FIREPIT
ANTI VORTEX
ECLIPSE DRAINS
ANTI VORTEX
CUSTOMER NUMBER:
DBX #
ADDED MATERIAL SELECTIONS 07.12.21
NPT AZUL-GRN-GRANITO-AZUL DEL MAR
2019 california building code ( BASED ON 2018 IBC )
2019 california mechanical code ( BASED ON 2018 UMC )
2019 california electrical code ( BASED ON 2017 NEC )
2019 california energy green code
electrical:
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE
GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26.
safety features:
* ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN
SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
2019 california plumbing code ( BASED ON 2018 UPC )TITLE 24, PART 5
GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON
PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL
DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED
IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE
INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE
EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR
NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR
OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED
2019 california residential code ( BASED ON 2018 IRC )
2019 california energy code
RESIDENCE
AVENIDA OBREGON
ELECTRIC CONDUIT
POOL / SPA LIGHT JUNCTION BOX
POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER
POOL EQUIPMENT 50 AMP SUBPANEL
WITH 36" CLEARANCE AT FRONT AND SIDE
MAIN HOUSE 200 AMP ELECTRICAL PANEL
INSTALL POOL EQUIPMENT 6"X8"X16"COLORED BLOCK
WALL AT +60"WITH 3'X5' WROUGHT IRON SERVICE GATE OPENING
(SEE WALL ENGINEERING BY ORCO ATTACHED)
TRANSFORMER
SAW CUT DEMO 36" CONCRETE DRIVEWAY FOR
PLUMBING RUNS AND INSTALL PAVER DECKING
POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART.
ANTI-COVERS 10" ASME / ANSI APPROVED
12"X6" WIDE BELGARD BRICK PAVER CONCRETE
CATALINA GRANA 3 PIECE LARGE PAVER DECKING
SAND SET OVER 4" OF COMPACTED ROAD BASE
AND 1" OF BEDDING SAND, POLYMERIC SAND
GROUT, MUD SET PAVER SOLDIER COURSE
INSTALL PROPERTY 6"X8"X16" TAN PRECISION BLOCK WALL
AT +72" WITH 3'X6' ENTRANCE WROUGHT IRON GATE OPENING
WITH MESH BACKING (SEE WALL ENGINEERING BY ORCO ATTACHED)
70 SQ. FT.POOL COPING
470 SQ. FT.PAVER DECKING
UNDERGROUND SERVICE ALERT
A PUBLIC SERVICE BY
BEFORE
YOU DIG
TOLL FREE
DIAL TWO WORKING
DAYS BEFORE
1-800-227-2600
YOU DIG
YES
OTHERS
YES
DEMO EXISTING WALKWAY (56 SQ. FT.) AND REPLACE WITH PAVERS
EXISTING GATE TO OPEN OUTWARDS SELF CLOSING + SELF LATCHING
WATER METER
SEWER
PALM TREE REMOVAL BY OTHERS
12'-0" SB FROM FACE OF CURB
STONE SCAPES AQUAL WHITE MINI
BELGARD VICTORIAN 3-PIECE SMALL
SEE SUPERINTENDENT
1
POOL EQUIPMENT: PROPANE HEATER
*ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED
HEATER TO BE SET ON A RACK
NEW LANDSCAPING TO
SURROUND PROPANE
TANK, LANDSCAPE BY
HOMEOWNER
PROPANE TANK INSTALLED BY SPECIALTY PROPANE COMPANY, GAS LINE
FROM HEATER TO PROPANE TANK BY TESERRA, HOOKUPS BY PROPANE COMPANY
8' - 11
2" POLYPROPYLENE GAS PIPE
12'-6" SB FROM FACE OF CURB
TO PROPANE TANK
JANDY 400,000 BTU PROPANE
ADDED PLANTER BED 10.05.21
3
adjusted pool and wall layout 09.01.21
EXISTING WOODEN FENCE 5'-0"HIGH
EXTEND NEW 5'-0" HIGH
MASONRY WALL 9' IN LENGTH
EXTEND NEW MASONRY WALL TO 9'-0",
ADD PAVERS SQFT.10.08.21
4
10/18/2021
REVISION 1 - DELTA 4 ONLY:
9LF OF 5' HIGH GARDEN
WALL [CITY STANDARD] 2019
CALIFORNIA BUILDING
CODES.
BPOL2021-0152