Loading...
BPOL2024-0052BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 02/22/2024 ISSUED DATE: 03/01/2024 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 81972 VIA SAN CLEMENTE BPOL2024-0052 764640035 Lot 56 MB 413/61 TR 31910 $35,000.00 RL, 56 Owner:Lori Arvizu Applicant:Yesenia Preciado 79125 CORPORATE CENTER WAY, LA QUINTA, CA 92248 Contractor:Yesenia Preciado / 1045465 79125 CORPORATE CENTER WAY, LA QUINTA, CA 92248 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 3/1/24 4:27 pm Page 1 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2024-0052 81972 VIA SAN CLEMENTE BUILDING PERMIT construction lender preliminary notice from that duty. Printed: 3/1/24 4:27 pm Page 2 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2024-0052 81972 VIA SAN CLEMENTE BUILDING PERMIT POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Use of Permit Construction Details Pools Engineering IncEngineer of Record 0Quantity of Detached Spa(s)/Water Feature(s) 5BBQ Electrical (EA) 2Number of Gas Outlet(s) 0Mechanical Equipment Relocation (QTY) 0Garden Wall Linear Foootage 0Combination Retaining Wall Linear Footage 0Total Wall Length (Linear Footage) RLZoning LDRGeneral Plan Within La Quinta LimitsCity Limits TR 31910Subdivision Name 56Lot Number 1442Lot Size 93302Centerlines Lot 56 MB 413/61 TR 31910 Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00004908 $30.51 Receptacle, switch, lighting, or other outlets $30.51 $228.84 Swimming Pool / Spa $228.84 $15.26 Gas Piping System Outlets $15.26 $30.51 Gas Piping System Outlets PC $30.51 $124.49 Swimming Pool / Spa PC $124.49 $2.00 Building Standards Administration $2.00 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $11.50 Credit Card Convenience Fee $11.50 $30.51 Receptacle, switch, lighting, or other outlets PC $30.51 $8.00 Technology Enhancement Fee $8.00 $493.62 $493.62 Total for Invoice INV-00004908 Grand Total for Permit $493.62 $493.62 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 02/22/2024 13:57 02/22/2024 13:58 Submittal Document Verification v.1 Generic Action 02/22/2024 13:58 Plan Check v.1 02/22/2024 0:00 02/23/2024 11:46 Building Review (1 Day) v.1 Receive Submittal 02/22/2024 0:00 02/23/2024 11:46 Permit Issuance v.1 02/23/2024 11:47 03/01/2024 8:27 Verify Contractor info & Conditions have been met v.1 Generic Action 02/23/2024 11:47 Verify & Invoice Fees v.1 Generic Action 03/01/2024 8:19 Verify Fee Payment & Issue Permit v.1 Generic Action 03/01/2024 8:27 Printed: 3/1/24 4:27 pm Page 3 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2024-0052 81972 VIA SAN CLEMENTE BUILDING PERMIT Print, Attach, and Email Building Permit v.1 Create Report 03/01/2024 8:27 03/01/2024 8:27 Pool Permit Inspection v.1 Pre-Gunite v.1 Inspection Underground Plumbing v.1 Inspection Underground Electrical v.1 Inspection Underground Gas v.1 Inspection Deck Bond v.1 Inspection Pre-Plaster v.1 Inspection Footing v.1 Inspection Bond Beam v.1 Inspection Inspections - Final v.1 Final Pool v.1 Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 3/1/24 4:27 pm Page 4 of 4 PERMIT INSPECTION HISTORY REPORT (BPOL2024-0052) FOR CITY OF LA QUINTA Pool 02/22/2024Application Date:Permit Type:764640035Parcel Pool Construction (Private)03/01/2024Work Class:Issue Date:81972 VIA SAN CLEMENTE LA QUINTA, CA 92253 Address: Finaled 07/30/2025Expiration Date:Status:Description:POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Owner:Contractor:Applicant:Lori Arvizu Yesenia Preciado Yesenia Preciado Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date 04/02/2024 04/02/2024 Pre-Gunite IBLD-017258-2024 Canceled Edward Ghera Yes Complete 04/02/2024 Underground Electrical IBLD-017261-2024 Canceled Edward Ghera Yes Complete COMMENTS ApprovedChecklist Item 04/02/2024 Underground Gas IBLD-017260-2024 Canceled Edward Ghera Yes Complete COMMENTS ApprovedChecklist Item 04/02/2024 Underground Plumbing IBLD-017259-2024 Canceled Edward Ghera Yes Complete COMMENTS ApprovedChecklist Item 04/03/2024 04/03/2024 Pre-Gunite IBLD-017364-2024 Approved Edward Ghera No Complete Reinspection of IBLD-017258-2024 04/03/2024 Underground Electrical IBLD-017366-2024 Partially Approved Edward Ghera Yes Incomplete Reinspection of IBLD-017261-2024 COMMENTS ApprovedChecklist Item Partial Approval FROM MAIN TO POOL EQUIPMENT AND POOL SHELL. PENDING INSPECTION OF BBQ ISLAND. Yes 04/03/2024 Underground Gas IBLD-017367-2024 Partially Approved Edward Ghera Yes Incomplete Reinspection of IBLD-017260-2024 COMMENTS ApprovedChecklist Item Partial Approval FROM MAIN TO POOL EQUIPMENT AND FIRE PIT. PENDING INSPECTION OF BBQ ISLAND. Yes 04/03/2024 Underground Plumbing IBLD-017365-2024 Approved Edward Ghera No Complete Reinspection of IBLD-017259-2024 78-495 Calle Tampico Page 1 of 2August 20, 2024 PERMIT INSPECTION HISTORY REPORT (BPOL2024-0052) Pool 02/22/2024Application Date:Permit Type:764640035Parcel Pool Construction (Private)03/01/2024Work Class:Issue Date:81972 VIA SAN CLEMENTE LA QUINTA, CA 92253 Address: Finaled 07/30/2025Expiration Date:Status:Description:POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Owner:Contractor:Applicant:Lori Arvizu Yesenia Preciado Yesenia Preciado Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date 04/09/2024 04/09/2024 Deck Bond IBLD-017802-2024 Approved Edward Ghera No Complete 05/31/2024 05/31/2024 Pre-Plaster IBLD-021304-2024 Approved with Exceptions Jake Fuson No Complete COMMENTS ApprovedChecklist Item Partial Approval PER AGREEMENT WITH CONTRACTOR, 2ND DROWNING PREVENTION DEVICE MUST BE PROVIDED AND INSTALLED AS SOON AS POOL IS FILLED WITH WATER- -TO BE VERIFIED AT FINAL INSPECTION. No 07/29/2024 07/29/2024 Final Pool IBLD-025236-2024 Disapproved Taylor Tuvell Yes Complete COMMENTS ApprovedChecklist Item Correction SECURE EQUIPMENT TO PAD WHERE DESIGNED TO BE SECURED No Correction BBQ NOT DONE No Correction MISSING SEDIMENT TRAP ON HEATER No Correction NEED GFI PROTECTION ON CHILLER PUMP No 07/30/2024 07/30/2024 Final Pool IBLD-025291-2024 Approved Edward Ghera No Complete Reinspection of IBLD-025236-2024 78-495 Calle Tampico Page 2 of 2August 20, 2024 (N) Grass (N) Concrete NSheet Size - A1 Scale: 1/8” = 1 ft electric 1" grey conduit pipe gas line 1 1/2" POLYETHELYNE pipe gas line to have #14 yellow trace wire installed Pipes are part of the pool equipment and any pipes emerging from the ground shall not encroach into the 5 ft setback or planning variance will be required All gas suppied devices shall have a shut off valve as per (CPC 1212.6) provide adequate workspace around electrical equipment per NEC 110.26(A)(2) gas and electrical pipes to be buried a minimum of 18" underground led's waterbond required Install drains asrequired Equipotential boding grid to be installed Pool heater and pool equipment to be installed per manufacturer specifications Pools Count:1 Envelope: Perimeter: Area: Int Surface Area: Depth: Volume: Drains: Lights: Interior Finish: Tile Line: Tile Material: Coping Material: Raised Beam Mtrl: Concrete: Rebar: Spa Count:1 Envelope: Perimeter: Area: Int Surface Area: Depth: Volume: Drains: Lights: Interior Finish: Tile Line: Tile Material: Coping Material: Raised Beam Mtrl: Concrete: Rebar: Electrical Line Run Linear Ft: Gas Line Run Linear Ft: 2022 California Building Code 2022 California Residential Code 2022 California Mechanical Code 2022 California Plumbing Code 2022 California Electrical Code 2022 California Energy Code 2022 California Green Building Standards Code GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDER DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITTIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114-MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATER AND ALL POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME). IDENTIFY A MINIMUM 3 FEET SEPARATION BETWEEN ALL DRAINS AND All Equipment Shall be Seismically Anchored No Overhead lines NOTE: ALL POOL HEATER INSTALLATIONS REQUIRE A CEC-CF2R-PLB-03-E FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO INSPECTION APPROVAL 1- ALL FLOORS AND WALLS OF POOL TO BE CONCRETE SHALL BE PNEUMATICALLY PLACED (SHOTCRETE) OR GUNITE A 28 DAY MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI 2- ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 60. 3- ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL WITH LOGO PRINTED 4- FILTER BACKWASH SHALL COMPLY WITH CHAPTER 424.20 OF THE FBC. 5- NO POOL OR SPA DECK SHALL BEAR ON AN TYPE OF SOILS EXCEPT CLEAN SANDS OR ROCK WHICH SHALL BE COMPACTED TO PROVIDE A SAFE BEARING CAPACITY OF 2000 PSF. ANY ORGANICS, MARLS OR OTHER TYPES OF DELETERIOUS MATERIALS ENCOUNTERED ON EXCAVATION SHALL BE REMOVED (DEMUCKED) IN THEIR ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH THE ACCEPTABLE SOIL AND COMPACTED IN 12" THICK LAYERS, WHERE THE CONTRACTOR CAN NOT REMOVE THE ORGANICS DUE TO WHATEVER CAUSED, THE POOL SHALL BE REDESIGNED FOR PILING 6- IN ALL CASES THE POOL CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM FAILURE BY SHORING, UNDERPINNING OR ANY OTHER METHOD IF REQUIRED. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURE. 7- THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES IF NECESSARY. CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. 8- CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT THE SITE. MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY IN GENERAL. HOLD A DISTANCE OF 10 FEET FROM OVERHEAD ELECTRIC LINES TO OPEN POOL WATER EDGE AND 5 FEET FROM UNDERGROUND ELECTRIC LINES. 9- POOL SLIDES TO BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF CONSUMER PRODUCTS SAFETY COMMISSION. W.D.C. 10- WHERE POOLS ABUT OR ARE PLACED NEARBY SEAWALLS OR BULKHEADS SPECIAL CARE SHALL BE EMPLOYED. THE WALLS SHALL BE IN GOOD CONDITIONS NOT PERMITING ANY SHIFTING OR REMOVAL OR LOOSENING OF THE SUPPORTING SOIL AWAY FROM THE POOL. IF THE WALLS DO NOT FULLY CONTAIN THE SOILS BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRED. CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED OF THE PROPERTY OWNER. WHEN EXCAVATING FOR THE POOL, THE SEAWALL TIEBACKS SHALL NOT BE CUT. WHERE CONCRETE DEADMEN FALL WITHIN THE EXCAVATION, NOTIFY THE ENGINEER FOR INSTRUCTIONS. 11- THE CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. BACKFILL SHALL BE ACCOMPLISHED WITH CLEAN SANDS FREE OF ORGANIC MATERIALS AND SHALL BE PLACED IN 12" THICK LAYERS. EACH LAYER SHALL BE COMPACTED TO 90% OF THE SOILS MAXIMUM DENSITY BY TAMPING SOLIDLY. SOILS BELOW THE PATIO SHALL BE PLACED IN A SIMILAR MANNER. 12- WHERE PATIOS ARE INDICTED BY OTHERS. THE PATIO DESIGN NOTES SHOWN ON THE TYPICAL WALL SECTION DO NOT APPLY. PATIO DESIGN SHALL BE BY OTHERS. 13- WARNING: TO EMPTY POOL AFTER CONSTRUCTION FOR REPAIRS OR ANY OTHER REASON, THE HYDROSTATIC UPLIFT PRESSURES BENEATH THE POOL MUST BE ELIMINATED TO PREVENT THE POOL FROM FLOATING UPWARD. THE OWNER MUST CONSULT AND POOL REPAIR CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURES. 14- THE PLANS REMAINS THE PROPERTY OF THE DESIGN ENGINEER. IT IS NON TRANSFERABLE FROM ONE CONTRACTOR TO ANOTHER WITHOUT THE WRITTEN PERMISSION OF THE DESIGN ENGINEER AND TO THE BEST OF OUR PROFESSIONAL KNOWLEDGE AND BELIEF, THEY HAVE BEEN PREPARED IN COMPLIANCE WITH THE ANSI-NSPI-5-1995 AND FBC AND ALL APPLICABLE LOCAL CODES AND REGULATIONS. 15- CONCRETE POOL DECK, SHALL BE PROVIDED W/1" WIDE SAW-CUT CRACK CONTROL JOINTS SPACED AT 5'-0" O.C. OR FOR AN EFFECTIVE CONCRETE AREA OF 150 SQ. FT. CRACK CONTROL JOINTS SHALL BE SAW-CUT AT A DEPTH OF 1/3 THE SLAB THICKNESS GENERAL NOTES Pool plan AN APPROVED 5FT HIGH FENCE/ BARRIER CONSTRUCTED OVER CONCRETE IS REQUIRED ALL THE WAY AROUND THE POOL AND SPA, WITH SELF CLOSING, SELF LATCHING GATE, AND OPEN OUTWARD AWAY FROM THE POOL. FENCE ENCLOSURE/ BARRIER MUST BE CONSTRUCTED OF APPROVED MATERIALS. FENCE MUST NOT BE CLIMBABLE AS MEASURED FROM THE OUTSIDE. OPENING OF BARRIER SHADE MUST NOT ALLOW PASSAGE OF A 4 INCH SPHERE DWELLING SERVING AS PART OF THE BARRIER SHALL BE EQUIPPED WITH AN ALARM THAT PRODUCES AN AUDIBLE WARNING. THE ALARM SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE LOCATED 54 INCHES OR MORE ABOVE THE THRESHOLD OF THE DOOR. ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREAS AS PER CEC ART. 680.26 SAFETY FEATURES ELECTRICAL GENERAL NOTES (N) Residence Scope of work: New Spa and pool 3’ 5’ Pool Equipment Electric Gas At least 36” of pipe shall be installed between the lter and the heater or dedicated suction and return lines, or built-in or built up connections shall be installed to allow for the future addition of solar and heating equipment A cover for outdoor pools or outdoor spas that have a heat pump or gas heater Drainage from the pool shall be retained on-site and conveyed to well-vegetated surfaces. Discharge to public street shall not be permitted unless the collected surface water is dechlorinated per NPDES MS4 regulations Existing 6’ Block Wall Electric panel and gas meter Gate Self Latching Self Closing 81972 Via San Clemente 81972 Via San Clemente Pool Equipment Split Drains 3’ apart10’ 34’ 7’5’ 7'-6" 114' 121' 90' P.L. P.L. P.L. P.L. 10’ PUE Drawn By Jose Villanueva 7’ 21'25' 8'-9" 9'-4" 9'-4" 18” Raised Spa (N) BBQ (N) 5’x2’ Firepit 6' Pool Equipment Disconnect Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg 02/23/2024J.ANAYA BPOL2024-0052 POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg02/23/2024J.ANAYA (N) Grass (N) Concrete NSheet Size - A1 Scale: 1/8” = 1 ft electric 1" grey conduit pipe gas line 1 1/2" POLYETHELYNE pipe gas line to have #14 yellow trace wire installed Pipes are part of the pool equipment and any pipes emerging from the ground shall not encroach into the 5 ft setback or planning variance will be required All gas suppied devices shall have a shut off valve as per (CPC 1212.6) provide adequate workspace around electrical equipment per NEC 110.26(A)(2) gas and electrical pipes to be buried a minimum of 18" underground led's waterbond required Install drains asrequired Equipotential boding grid to be installed Pool heater and pool equipment to be installed per manufacturer specifications Pools Count:1 Envelope: Perimeter: Area: Int Surface Area: Depth: Volume: Drains: Lights: Interior Finish: Tile Line: Tile Material: Coping Material: Raised Beam Mtrl: Concrete: Rebar: Spa Count:1 Envelope: Perimeter: Area: Int Surface Area: Depth: Volume: Drains: Lights: Interior Finish: Tile Line: Tile Material: Coping Material: Raised Beam Mtrl: Concrete: Rebar: Electrical Line Run Linear Ft: Gas Line Run Linear Ft: 2022 California Building Code 2022 California Residential Code 2022 California Mechanical Code 2022 California Plumbing Code 2022 California Electrical Code 2022 California Energy Code 2022 California Green Building Standards Code GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDER DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITTIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114-MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATER AND ALL POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME). IDENTIFY A MINIMUM 3 FEET SEPARATION BETWEEN ALL DRAINS AND All Equipment Shall be Seismically Anchored No Overhead lines NOTE: ALL POOL HEATER INSTALLATIONS REQUIRE A CEC-CF2R-PLB-03-E FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO INSPECTION APPROVAL 1- ALL FLOORS AND WALLS OF POOL TO BE CONCRETE SHALL BE PNEUMATICALLY PLACED (SHOTCRETE) OR GUNITE A 28 DAY MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI 2- ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 60. 3- ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL WITH LOGO PRINTED 4- FILTER BACKWASH SHALL COMPLY WITH CHAPTER 424.20 OF THE FBC. 5- NO POOL OR SPA DECK SHALL BEAR ON AN TYPE OF SOILS EXCEPT CLEAN SANDS OR ROCK WHICH SHALL BE COMPACTED TO PROVIDE A SAFE BEARING CAPACITY OF 2000 PSF. ANY ORGANICS, MARLS OR OTHER TYPES OF DELETERIOUS MATERIALS ENCOUNTERED ON EXCAVATION SHALL BE REMOVED (DEMUCKED) IN THEIR ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH THE ACCEPTABLE SOIL AND COMPACTED IN 12" THICK LAYERS, WHERE THE CONTRACTOR CAN NOT REMOVE THE ORGANICS DUE TO WHATEVER CAUSED, THE POOL SHALL BE REDESIGNED FOR PILING 6- IN ALL CASES THE POOL CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM FAILURE BY SHORING, UNDERPINNING OR ANY OTHER METHOD IF REQUIRED. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURE. 7- THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES IF NECESSARY. CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. 8- CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT THE SITE. MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY IN GENERAL. HOLD A DISTANCE OF 10 FEET FROM OVERHEAD ELECTRIC LINES TO OPEN POOL WATER EDGE AND 5 FEET FROM UNDERGROUND ELECTRIC LINES. 9- POOL SLIDES TO BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF CONSUMER PRODUCTS SAFETY COMMISSION. W.D.C. 10- WHERE POOLS ABUT OR ARE PLACED NEARBY SEAWALLS OR BULKHEADS SPECIAL CARE SHALL BE EMPLOYED. THE WALLS SHALL BE IN GOOD CONDITIONS NOT PERMITING ANY SHIFTING OR REMOVAL OR LOOSENING OF THE SUPPORTING SOIL AWAY FROM THE POOL. IF THE WALLS DO NOT FULLY CONTAIN THE SOILS BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRED. CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED OF THE PROPERTY OWNER. WHEN EXCAVATING FOR THE POOL, THE SEAWALL TIEBACKS SHALL NOT BE CUT. WHERE CONCRETE DEADMEN FALL WITHIN THE EXCAVATION, NOTIFY THE ENGINEER FOR INSTRUCTIONS. 11- THE CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. BACKFILL SHALL BE ACCOMPLISHED WITH CLEAN SANDS FREE OF ORGANIC MATERIALS AND SHALL BE PLACED IN 12" THICK LAYERS. EACH LAYER SHALL BE COMPACTED TO 90% OF THE SOILS MAXIMUM DENSITY BY TAMPING SOLIDLY. SOILS BELOW THE PATIO SHALL BE PLACED IN A SIMILAR MANNER. 12- WHERE PATIOS ARE INDICTED BY OTHERS. THE PATIO DESIGN NOTES SHOWN ON THE TYPICAL WALL SECTION DO NOT APPLY. PATIO DESIGN SHALL BE BY OTHERS. 13- WARNING: TO EMPTY POOL AFTER CONSTRUCTION FOR REPAIRS OR ANY OTHER REASON, THE HYDROSTATIC UPLIFT PRESSURES BENEATH THE POOL MUST BE ELIMINATED TO PREVENT THE POOL FROM FLOATING UPWARD. THE OWNER MUST CONSULT AND POOL REPAIR CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURES. 14- THE PLANS REMAINS THE PROPERTY OF THE DESIGN ENGINEER. IT IS NON TRANSFERABLE FROM ONE CONTRACTOR TO ANOTHER WITHOUT THE WRITTEN PERMISSION OF THE DESIGN ENGINEER AND TO THE BEST OF OUR PROFESSIONAL KNOWLEDGE AND BELIEF, THEY HAVE BEEN PREPARED IN COMPLIANCE WITH THE ANSI-NSPI-5-1995 AND FBC AND ALL APPLICABLE LOCAL CODES AND REGULATIONS. 15- CONCRETE POOL DECK, SHALL BE PROVIDED W/1" WIDE SAW-CUT CRACK CONTROL JOINTS SPACED AT 5'-0" O.C. OR FOR AN EFFECTIVE CONCRETE AREA OF 150 SQ. FT. CRACK CONTROL JOINTS SHALL BE SAW-CUT AT A DEPTH OF 1/3 THE SLAB THICKNESS GENERAL NOTES Pool plan AN APPROVED 5FT HIGH FENCE/ BARRIER CONSTRUCTED OVER CONCRETE IS REQUIRED ALL THE WAY AROUND THE POOL AND SPA, WITH SELF CLOSING, SELF LATCHING GATE, AND OPEN OUTWARD AWAY FROM THE POOL. FENCE ENCLOSURE/ BARRIER MUST BE CONSTRUCTED OF APPROVED MATERIALS. FENCE MUST NOT BE CLIMBABLE AS MEASURED FROM THE OUTSIDE. OPENING OF BARRIER SHADE MUST NOT ALLOW PASSAGE OF A 4 INCH SPHERE DWELLING SERVING AS PART OF THE BARRIER SHALL BE EQUIPPED WITH AN ALARM THAT PRODUCES AN AUDIBLE WARNING. THE ALARM SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE LOCATED 54 INCHES OR MORE ABOVE THE THRESHOLD OF THE DOOR. ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREAS AS PER CEC ART. 680.26 SAFETY FEATURES ELECTRICAL GENERAL NOTES (N) Residence Scope of work: New Spa and pool 3’ 5’ Pool Equipment Electric Gas At least 36” of pipe shall be installed between the lter and the heater or dedicated suction and return lines, or built-in or built up connections shall be installed to allow for the future addition of solar and heating equipment A cover for outdoor pools or outdoor spas that have a heat pump or gas heater Drainage from the pool shall be retained on-site and conveyed to well-vegetated surfaces. Discharge to public street shall not be permitted unless the collected surface water is dechlorinated per NPDES MS4 regulations Existing 6’ Block Wall Electric panel and gas meter Gate Self Latching Self Closing 81972 Via San Clemente 81972 Via San Clemente Pool Equipment Split Drains 3’ apart10’ 34’ 7’5’ 7'-6" 114' 121' 90' P.L. P.L. P.L. P.L. 10’ PUE Drawn By Jose Villanueva 7’ 21'25' 8'-9" 9'-4" 9'-4" 18” Raised Spa (N) BBQ (N) 5’x2’ Firepit 6' Pool Equipment Disconnect Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg 02/23/2024J.ANAYA BPOL2024-0052 POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg02/23/2024J.ANAYA