BPOL2024-0052BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 02/22/2024
ISSUED DATE: 03/01/2024
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Pool
81972 VIA SAN CLEMENTE
BPOL2024-0052
764640035
Lot 56 MB 413/61 TR 31910
$35,000.00
RL, 56
Owner:Lori Arvizu
Applicant:Yesenia Preciado
79125 CORPORATE CENTER WAY, LA QUINTA,
CA 92248
Contractor:Yesenia Preciado / 1045465
79125 CORPORATE CENTER WAY, LA QUINTA,
CA 92248
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 3/1/24 4:27 pm Page 1 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0052
81972 VIA SAN CLEMENTE
BUILDING PERMIT
construction lender preliminary notice from that duty.
Printed: 3/1/24 4:27 pm Page 2 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0052
81972 VIA SAN CLEMENTE
BUILDING PERMIT
POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE.
APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO
DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
Use of Permit
Construction Details
Pools Engineering IncEngineer of Record 0Quantity of Detached
Spa(s)/Water
Feature(s)
5BBQ Electrical (EA)
2Number of Gas
Outlet(s)
0Mechanical Equipment
Relocation (QTY)
0Garden Wall Linear
Foootage
0Combination Retaining
Wall Linear Footage
0Total Wall Length
(Linear Footage)
RLZoning
LDRGeneral Plan Within La Quinta LimitsCity Limits TR 31910Subdivision Name
56Lot Number 1442Lot Size 93302Centerlines
Lot 56 MB 413/61 TR
31910
Legal Description
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
INV-00004908 $30.51 Receptacle, switch, lighting, or other outlets $30.51
$228.84 Swimming Pool / Spa $228.84
$15.26 Gas Piping System Outlets $15.26
$30.51 Gas Piping System Outlets PC $30.51
$124.49 Swimming Pool / Spa PC $124.49
$2.00 Building Standards Administration $2.00
$12.00 Digital Archiving and Records Management Fee - OTC $12.00
$11.50 Credit Card Convenience Fee $11.50
$30.51 Receptacle, switch, lighting, or other outlets PC $30.51
$8.00 Technology Enhancement Fee $8.00
$493.62 $493.62 Total for Invoice INV-00004908
Grand Total for Permit $493.62 $493.62
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Application Completeness Check v.1 02/22/2024 13:57 02/22/2024 13:58
Submittal Document Verification v.1 Generic Action 02/22/2024 13:58
Plan Check v.1 02/22/2024 0:00 02/23/2024 11:46
Building Review (1 Day) v.1 Receive Submittal 02/22/2024 0:00 02/23/2024 11:46
Permit Issuance v.1 02/23/2024 11:47 03/01/2024 8:27
Verify Contractor info & Conditions have been met v.1 Generic Action 02/23/2024 11:47
Verify & Invoice Fees v.1 Generic Action 03/01/2024 8:19
Verify Fee Payment & Issue Permit v.1 Generic Action 03/01/2024 8:27
Printed: 3/1/24 4:27 pm Page 3 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0052
81972 VIA SAN CLEMENTE
BUILDING PERMIT
Print, Attach, and Email Building Permit v.1 Create Report 03/01/2024 8:27 03/01/2024 8:27
Pool Permit Inspection v.1
Pre-Gunite v.1 Inspection
Underground Plumbing v.1 Inspection
Underground Electrical v.1 Inspection
Underground Gas v.1 Inspection
Deck Bond v.1 Inspection
Pre-Plaster v.1 Inspection
Footing v.1 Inspection
Bond Beam v.1 Inspection
Inspections - Final v.1
Final Pool v.1 Inspection
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 3/1/24 4:27 pm Page 4 of 4
PERMIT INSPECTION HISTORY REPORT (BPOL2024-0052)
FOR CITY OF LA QUINTA
Pool 02/22/2024Application Date:Permit Type:764640035Parcel
Pool Construction (Private)03/01/2024Work Class:Issue Date:81972 VIA SAN CLEMENTE
LA QUINTA, CA 92253
Address:
Finaled 07/30/2025Expiration Date:Status:Description:POOL AND SPA, FIRE PIT AT REAR
YARD [POOL ENGINEERING] THIS
PERMIT DOES NOT INCLUDE
EQUIPMENT ENCLOSURE. APPROVED
SITE PLAN AND WET STAMPED POOL
ENGINEERING SHEET REQUIRED TO
BE ONSITE FOR INSPECTION. TWO
DROWNING PREVENTION SAFETY
FEATURES AND THE REQUIRED
ENCLOSURE SHALL BE IN PLACE AT
PRE-PLASTER INSPECTION. 2022
CALIFORNIA BUILDING CODE.
Owner:Contractor:Applicant:Lori Arvizu Yesenia Preciado Yesenia Preciado
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection
Required?CompleteActual
Start Date
04/02/2024 04/02/2024 Pre-Gunite IBLD-017258-2024 Canceled Edward Ghera Yes Complete
04/02/2024 Underground
Electrical
IBLD-017261-2024 Canceled Edward Ghera Yes Complete
COMMENTS ApprovedChecklist Item
04/02/2024 Underground Gas IBLD-017260-2024 Canceled Edward Ghera Yes Complete
COMMENTS ApprovedChecklist Item
04/02/2024 Underground
Plumbing
IBLD-017259-2024 Canceled Edward Ghera Yes Complete
COMMENTS ApprovedChecklist Item
04/03/2024 04/03/2024 Pre-Gunite IBLD-017364-2024 Approved Edward Ghera No Complete
Reinspection of IBLD-017258-2024
04/03/2024 Underground
Electrical
IBLD-017366-2024 Partially Approved Edward Ghera Yes Incomplete
Reinspection of IBLD-017261-2024
COMMENTS ApprovedChecklist Item
Partial Approval FROM MAIN TO POOL EQUIPMENT AND POOL SHELL.
PENDING INSPECTION OF BBQ ISLAND.
Yes
04/03/2024 Underground Gas IBLD-017367-2024 Partially Approved Edward Ghera Yes Incomplete
Reinspection of IBLD-017260-2024
COMMENTS ApprovedChecklist Item
Partial Approval FROM MAIN TO POOL EQUIPMENT AND FIRE PIT.
PENDING INSPECTION OF BBQ ISLAND.
Yes
04/03/2024 Underground
Plumbing
IBLD-017365-2024 Approved Edward Ghera No Complete
Reinspection of IBLD-017259-2024
78-495 Calle Tampico Page 1 of 2August 20, 2024
PERMIT INSPECTION HISTORY REPORT (BPOL2024-0052)
Pool 02/22/2024Application Date:Permit Type:764640035Parcel
Pool Construction (Private)03/01/2024Work Class:Issue Date:81972 VIA SAN CLEMENTE
LA QUINTA, CA 92253
Address:
Finaled 07/30/2025Expiration Date:Status:Description:POOL AND SPA, FIRE PIT AT REAR
YARD [POOL ENGINEERING] THIS
PERMIT DOES NOT INCLUDE
EQUIPMENT ENCLOSURE. APPROVED
SITE PLAN AND WET STAMPED POOL
ENGINEERING SHEET REQUIRED TO
BE ONSITE FOR INSPECTION. TWO
DROWNING PREVENTION SAFETY
FEATURES AND THE REQUIRED
ENCLOSURE SHALL BE IN PLACE AT
PRE-PLASTER INSPECTION. 2022
CALIFORNIA BUILDING CODE.
Owner:Contractor:Applicant:Lori Arvizu Yesenia Preciado Yesenia Preciado
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection
Required?CompleteActual
Start Date
04/09/2024 04/09/2024 Deck Bond IBLD-017802-2024 Approved Edward Ghera No Complete
05/31/2024 05/31/2024 Pre-Plaster IBLD-021304-2024 Approved with
Exceptions
Jake Fuson No Complete
COMMENTS ApprovedChecklist Item
Partial Approval PER AGREEMENT WITH CONTRACTOR, 2ND DROWNING
PREVENTION DEVICE MUST BE PROVIDED AND
INSTALLED AS SOON AS POOL IS FILLED WITH WATER-
-TO BE VERIFIED AT FINAL INSPECTION.
No
07/29/2024 07/29/2024 Final Pool IBLD-025236-2024 Disapproved Taylor Tuvell Yes Complete
COMMENTS ApprovedChecklist Item
Correction SECURE EQUIPMENT TO PAD WHERE DESIGNED TO BE
SECURED
No
Correction BBQ NOT DONE No
Correction MISSING SEDIMENT TRAP ON HEATER No
Correction NEED GFI PROTECTION ON CHILLER PUMP No
07/30/2024 07/30/2024 Final Pool IBLD-025291-2024 Approved Edward Ghera No Complete
Reinspection of IBLD-025236-2024
78-495 Calle Tampico Page 2 of 2August 20, 2024
(N) Grass
(N) Concrete NSheet Size - A1 Scale: 1/8” = 1 ft
electric 1" grey
conduit pipe
gas line 1 1/2"
POLYETHELYNE pipe
gas line to have #14
yellow trace wire
installed
Pipes are part of
the pool
equipment and
any pipes
emerging from the
ground shall not
encroach into the
5 ft setback or
planning variance
will be required
All gas suppied
devices shall have
a shut off valve as
per (CPC 1212.6)
provide adequate
workspace around
electrical
equipment per
NEC 110.26(A)(2)
gas and electrical
pipes to be buried
a minimum of 18"
underground
led's waterbond
required
Install drains asrequired
Equipotential boding
grid to be installed
Pool heater and
pool equipment to
be installed per
manufacturer
specifications
Pools
Count:1
Envelope:
Perimeter:
Area:
Int Surface Area:
Depth:
Volume:
Drains:
Lights:
Interior Finish:
Tile Line:
Tile Material:
Coping Material:
Raised Beam Mtrl:
Concrete:
Rebar:
Spa
Count:1
Envelope:
Perimeter:
Area:
Int Surface Area:
Depth:
Volume:
Drains:
Lights:
Interior Finish:
Tile Line:
Tile Material:
Coping Material:
Raised Beam Mtrl:
Concrete:
Rebar:
Electrical Line Run
Linear Ft:
Gas Line Run
Linear Ft:
2022 California Building Code
2022 California Residential Code
2022 California Mechanical Code
2022 California Plumbing Code
2022 California Electrical Code
2022 California Energy Code
2022 California Green Building Standards Code
GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY
PERSON PLANNING TO TO CONDUCT ANY EXCAVATION SHALL CONTACT THE
APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS,
BUT NOT MORE THAN 14 CALENDER DAYS, PRIOR COMMENCING THAT EXCAVATION,
IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR
REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS
OTHER THAN THE UNDERGROUND FACILITTIES OWNED OR OPERATED BY THE
EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE
PAINT OR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH
SECTION 114-MANDATORY REQUIREMENTS
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE
POOL
POOL HEATER AND ALL POOL EQUIPMENT SHALL BE INSTALLED PER
MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL
REGULATIONS
PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT
STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR
THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS
(ASME). IDENTIFY A MINIMUM 3 FEET SEPARATION BETWEEN ALL DRAINS AND
All Equipment Shall be Seismically Anchored
No Overhead lines
NOTE: ALL POOL HEATER INSTALLATIONS REQUIRE A
CEC-CF2R-PLB-03-E FORM TO BE COMPLETED AND SIGNED BY
THE INSTALLER OF RECORD AND SUBMITTED TO THE
BUILDING INSPECTOR PRIOR TO INSPECTION APPROVAL
1- ALL FLOORS AND WALLS OF POOL TO BE CONCRETE SHALL BE
PNEUMATICALLY PLACED (SHOTCRETE) OR GUNITE A 28 DAY
MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI
2- ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE
60.
3- ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF
APPROVAL WITH LOGO PRINTED
4- FILTER BACKWASH SHALL COMPLY WITH CHAPTER 424.20 OF
THE FBC.
5- NO POOL OR SPA DECK SHALL BEAR ON AN TYPE OF SOILS
EXCEPT CLEAN SANDS OR ROCK WHICH SHALL BE COMPACTED TO
PROVIDE A SAFE BEARING CAPACITY OF 2000 PSF. ANY
ORGANICS, MARLS OR OTHER TYPES OF DELETERIOUS MATERIALS
ENCOUNTERED ON EXCAVATION SHALL BE REMOVED (DEMUCKED)
IN THEIR ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH
THE ACCEPTABLE SOIL AND COMPACTED IN 12" THICK LAYERS,
WHERE THE CONTRACTOR CAN NOT REMOVE THE ORGANICS DUE
TO WHATEVER CAUSED, THE POOL SHALL BE REDESIGNED FOR
PILING
6- IN ALL CASES THE POOL CONTRACTOR SHALL TAKE ALL
PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM
FAILURE BY SHORING, UNDERPINNING OR ANY OTHER METHOD IF
REQUIRED. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY
FOR THE SAFETY OF EXISTING STRUCTURE.
7- THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR
POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS
AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF
THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL
CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND
ESTABLISH LOT LINES IF NECESSARY. CONTRACTOR AND/OR
OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS
PRIOR TO CONSTRUCTION.
8- CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT
THE SITE. MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD
AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY
IN GENERAL. HOLD A DISTANCE OF 10 FEET FROM OVERHEAD
ELECTRIC LINES TO OPEN POOL WATER EDGE AND 5 FEET FROM
UNDERGROUND ELECTRIC LINES.
9- POOL SLIDES TO BE INSTALLED IN ACCORDANCE WITH THE
LATEST EDITION OF CONSUMER PRODUCTS SAFETY COMMISSION.
W.D.C.
10- WHERE POOLS ABUT OR ARE PLACED NEARBY SEAWALLS OR
BULKHEADS SPECIAL CARE SHALL BE EMPLOYED. THE WALLS
SHALL BE IN GOOD CONDITIONS NOT PERMITING ANY SHIFTING
OR REMOVAL OR LOOSENING OF THE SUPPORTING SOIL AWAY
FROM THE POOL. IF THE WALLS DO NOT FULLY CONTAIN THE
SOILS BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRED.
CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED OF THE
PROPERTY OWNER. WHEN EXCAVATING FOR THE POOL, THE
SEAWALL TIEBACKS SHALL NOT BE CUT. WHERE CONCRETE
DEADMEN FALL WITHIN THE EXCAVATION, NOTIFY THE ENGINEER
FOR INSTRUCTIONS.
11- THE CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH
CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. BACKFILL
SHALL BE ACCOMPLISHED WITH CLEAN SANDS FREE OF ORGANIC
MATERIALS AND SHALL BE PLACED IN 12" THICK LAYERS. EACH
LAYER SHALL BE COMPACTED TO 90% OF THE SOILS MAXIMUM
DENSITY BY TAMPING SOLIDLY. SOILS BELOW THE PATIO SHALL
BE PLACED IN A SIMILAR MANNER.
12- WHERE PATIOS ARE INDICTED BY OTHERS. THE PATIO
DESIGN NOTES SHOWN ON THE TYPICAL WALL SECTION DO NOT
APPLY. PATIO DESIGN SHALL BE BY OTHERS.
13- WARNING: TO EMPTY POOL AFTER CONSTRUCTION FOR
REPAIRS OR ANY OTHER REASON, THE HYDROSTATIC UPLIFT
PRESSURES BENEATH THE POOL MUST BE ELIMINATED TO
PREVENT THE POOL FROM FLOATING UPWARD. THE OWNER MUST
CONSULT AND POOL REPAIR CONTRACTOR EXPERIENCED IN
ELIMINATING UPLIFT PRESSURES.
14- THE PLANS REMAINS THE PROPERTY OF THE DESIGN
ENGINEER. IT IS NON TRANSFERABLE FROM ONE CONTRACTOR
TO ANOTHER WITHOUT THE WRITTEN PERMISSION OF THE
DESIGN ENGINEER AND TO THE BEST OF OUR PROFESSIONAL
KNOWLEDGE AND BELIEF, THEY HAVE BEEN PREPARED IN
COMPLIANCE WITH THE ANSI-NSPI-5-1995 AND FBC AND ALL
APPLICABLE LOCAL CODES AND REGULATIONS.
15- CONCRETE POOL DECK, SHALL BE PROVIDED W/1" WIDE
SAW-CUT CRACK CONTROL JOINTS SPACED AT 5'-0" O.C. OR FOR
AN EFFECTIVE CONCRETE AREA OF 150 SQ. FT. CRACK CONTROL
JOINTS SHALL BE SAW-CUT AT A DEPTH OF 1/3 THE SLAB
THICKNESS
GENERAL NOTES
Pool plan
AN APPROVED 5FT HIGH FENCE/ BARRIER CONSTRUCTED OVER CONCRETE IS REQUIRED ALL
THE WAY AROUND THE POOL AND SPA, WITH SELF CLOSING, SELF LATCHING GATE, AND OPEN
OUTWARD AWAY FROM THE POOL. FENCE ENCLOSURE/ BARRIER MUST BE CONSTRUCTED OF
APPROVED MATERIALS. FENCE MUST NOT BE CLIMBABLE AS MEASURED FROM THE OUTSIDE.
OPENING OF BARRIER SHADE MUST NOT ALLOW PASSAGE OF A 4 INCH SPHERE
DWELLING SERVING AS PART OF THE BARRIER SHALL BE EQUIPPED WITH AN ALARM THAT
PRODUCES AN AUDIBLE WARNING. THE ALARM SHALL BE LISTED AND LABELED IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE LOCATED 54 INCHES OR
MORE ABOVE THE THRESHOLD OF THE DOOR.
ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE
AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF
MECHANICAL ENGINEERS (ASME)
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE
VOLTAGE GRADIENTS IN THE POOL AREAS AS PER CEC ART. 680.26
SAFETY FEATURES
ELECTRICAL
GENERAL NOTES
(N) Residence
Scope of work: New Spa and pool
3’
5’
Pool Equipment
Electric
Gas
At least 36” of pipe shall be installed
between the lter and the heater or dedicated
suction and return lines, or built-in or built up connections
shall be installed to allow for the future addition of solar
and heating equipment
A cover for outdoor pools or outdoor spas that have a heat pump
or gas heater
Drainage from the pool shall be retained on-site and
conveyed to well-vegetated surfaces.
Discharge to public street shall not be permitted unless
the collected surface water is
dechlorinated per NPDES MS4 regulations
Existing 6’
Block Wall
Electric panel and
gas meter
Gate Self Latching
Self Closing
81972 Via San Clemente
81972 Via San Clemente
Pool Equipment
Split Drains
3’ apart10’
34’
7’5’
7'-6"
114'
121'
90'
P.L.
P.L.
P.L.
P.L.
10’ PUE
Drawn By Jose Villanueva
7’
21'25'
8'-9"
9'-4"
9'-4"
18” Raised Spa
(N) BBQ
(N) 5’x2’ Firepit
6'
Pool Equipment
Disconnect
Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg
02/23/2024J.ANAYA
BPOL2024-0052
POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING]
THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE.
APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING
SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO
DROWNING PREVENTION SAFETY FEATURES AND THE
REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg02/23/2024J.ANAYA
(N) Grass
(N) Concrete NSheet Size - A1 Scale: 1/8” = 1 ft
electric 1" grey
conduit pipe
gas line 1 1/2"
POLYETHELYNE pipe
gas line to have #14
yellow trace wire
installed
Pipes are part of
the pool
equipment and
any pipes
emerging from the
ground shall not
encroach into the
5 ft setback or
planning variance
will be required
All gas suppied
devices shall have
a shut off valve as
per (CPC 1212.6)
provide adequate
workspace around
electrical
equipment per
NEC 110.26(A)(2)
gas and electrical
pipes to be buried
a minimum of 18"
underground
led's waterbond
required
Install drains asrequired
Equipotential boding
grid to be installed
Pool heater and
pool equipment to
be installed per
manufacturer
specifications
Pools
Count:1
Envelope:
Perimeter:
Area:
Int Surface Area:
Depth:
Volume:
Drains:
Lights:
Interior Finish:
Tile Line:
Tile Material:
Coping Material:
Raised Beam Mtrl:
Concrete:
Rebar:
Spa
Count:1
Envelope:
Perimeter:
Area:
Int Surface Area:
Depth:
Volume:
Drains:
Lights:
Interior Finish:
Tile Line:
Tile Material:
Coping Material:
Raised Beam Mtrl:
Concrete:
Rebar:
Electrical Line Run
Linear Ft:
Gas Line Run
Linear Ft:
2022 California Building Code
2022 California Residential Code
2022 California Mechanical Code
2022 California Plumbing Code
2022 California Electrical Code
2022 California Energy Code
2022 California Green Building Standards Code
GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY
PERSON PLANNING TO TO CONDUCT ANY EXCAVATION SHALL CONTACT THE
APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS,
BUT NOT MORE THAN 14 CALENDER DAYS, PRIOR COMMENCING THAT EXCAVATION,
IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR
REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS
OTHER THAN THE UNDERGROUND FACILITTIES OWNED OR OPERATED BY THE
EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE
PAINT OR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH
SECTION 114-MANDATORY REQUIREMENTS
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE
POOL
POOL HEATER AND ALL POOL EQUIPMENT SHALL BE INSTALLED PER
MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL
REGULATIONS
PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT
STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR
THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS
(ASME). IDENTIFY A MINIMUM 3 FEET SEPARATION BETWEEN ALL DRAINS AND
All Equipment Shall be Seismically Anchored
No Overhead lines
NOTE: ALL POOL HEATER INSTALLATIONS REQUIRE A
CEC-CF2R-PLB-03-E FORM TO BE COMPLETED AND SIGNED BY
THE INSTALLER OF RECORD AND SUBMITTED TO THE
BUILDING INSPECTOR PRIOR TO INSPECTION APPROVAL
1- ALL FLOORS AND WALLS OF POOL TO BE CONCRETE SHALL BE
PNEUMATICALLY PLACED (SHOTCRETE) OR GUNITE A 28 DAY
MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI
2- ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE
60.
3- ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF
APPROVAL WITH LOGO PRINTED
4- FILTER BACKWASH SHALL COMPLY WITH CHAPTER 424.20 OF
THE FBC.
5- NO POOL OR SPA DECK SHALL BEAR ON AN TYPE OF SOILS
EXCEPT CLEAN SANDS OR ROCK WHICH SHALL BE COMPACTED TO
PROVIDE A SAFE BEARING CAPACITY OF 2000 PSF. ANY
ORGANICS, MARLS OR OTHER TYPES OF DELETERIOUS MATERIALS
ENCOUNTERED ON EXCAVATION SHALL BE REMOVED (DEMUCKED)
IN THEIR ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH
THE ACCEPTABLE SOIL AND COMPACTED IN 12" THICK LAYERS,
WHERE THE CONTRACTOR CAN NOT REMOVE THE ORGANICS DUE
TO WHATEVER CAUSED, THE POOL SHALL BE REDESIGNED FOR
PILING
6- IN ALL CASES THE POOL CONTRACTOR SHALL TAKE ALL
PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM
FAILURE BY SHORING, UNDERPINNING OR ANY OTHER METHOD IF
REQUIRED. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY
FOR THE SAFETY OF EXISTING STRUCTURE.
7- THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR
POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS
AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF
THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL
CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND
ESTABLISH LOT LINES IF NECESSARY. CONTRACTOR AND/OR
OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS
PRIOR TO CONSTRUCTION.
8- CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT
THE SITE. MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD
AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY
IN GENERAL. HOLD A DISTANCE OF 10 FEET FROM OVERHEAD
ELECTRIC LINES TO OPEN POOL WATER EDGE AND 5 FEET FROM
UNDERGROUND ELECTRIC LINES.
9- POOL SLIDES TO BE INSTALLED IN ACCORDANCE WITH THE
LATEST EDITION OF CONSUMER PRODUCTS SAFETY COMMISSION.
W.D.C.
10- WHERE POOLS ABUT OR ARE PLACED NEARBY SEAWALLS OR
BULKHEADS SPECIAL CARE SHALL BE EMPLOYED. THE WALLS
SHALL BE IN GOOD CONDITIONS NOT PERMITING ANY SHIFTING
OR REMOVAL OR LOOSENING OF THE SUPPORTING SOIL AWAY
FROM THE POOL. IF THE WALLS DO NOT FULLY CONTAIN THE
SOILS BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRED.
CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED OF THE
PROPERTY OWNER. WHEN EXCAVATING FOR THE POOL, THE
SEAWALL TIEBACKS SHALL NOT BE CUT. WHERE CONCRETE
DEADMEN FALL WITHIN THE EXCAVATION, NOTIFY THE ENGINEER
FOR INSTRUCTIONS.
11- THE CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH
CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. BACKFILL
SHALL BE ACCOMPLISHED WITH CLEAN SANDS FREE OF ORGANIC
MATERIALS AND SHALL BE PLACED IN 12" THICK LAYERS. EACH
LAYER SHALL BE COMPACTED TO 90% OF THE SOILS MAXIMUM
DENSITY BY TAMPING SOLIDLY. SOILS BELOW THE PATIO SHALL
BE PLACED IN A SIMILAR MANNER.
12- WHERE PATIOS ARE INDICTED BY OTHERS. THE PATIO
DESIGN NOTES SHOWN ON THE TYPICAL WALL SECTION DO NOT
APPLY. PATIO DESIGN SHALL BE BY OTHERS.
13- WARNING: TO EMPTY POOL AFTER CONSTRUCTION FOR
REPAIRS OR ANY OTHER REASON, THE HYDROSTATIC UPLIFT
PRESSURES BENEATH THE POOL MUST BE ELIMINATED TO
PREVENT THE POOL FROM FLOATING UPWARD. THE OWNER MUST
CONSULT AND POOL REPAIR CONTRACTOR EXPERIENCED IN
ELIMINATING UPLIFT PRESSURES.
14- THE PLANS REMAINS THE PROPERTY OF THE DESIGN
ENGINEER. IT IS NON TRANSFERABLE FROM ONE CONTRACTOR
TO ANOTHER WITHOUT THE WRITTEN PERMISSION OF THE
DESIGN ENGINEER AND TO THE BEST OF OUR PROFESSIONAL
KNOWLEDGE AND BELIEF, THEY HAVE BEEN PREPARED IN
COMPLIANCE WITH THE ANSI-NSPI-5-1995 AND FBC AND ALL
APPLICABLE LOCAL CODES AND REGULATIONS.
15- CONCRETE POOL DECK, SHALL BE PROVIDED W/1" WIDE
SAW-CUT CRACK CONTROL JOINTS SPACED AT 5'-0" O.C. OR FOR
AN EFFECTIVE CONCRETE AREA OF 150 SQ. FT. CRACK CONTROL
JOINTS SHALL BE SAW-CUT AT A DEPTH OF 1/3 THE SLAB
THICKNESS
GENERAL NOTES
Pool plan
AN APPROVED 5FT HIGH FENCE/ BARRIER CONSTRUCTED OVER CONCRETE IS REQUIRED ALL
THE WAY AROUND THE POOL AND SPA, WITH SELF CLOSING, SELF LATCHING GATE, AND OPEN
OUTWARD AWAY FROM THE POOL. FENCE ENCLOSURE/ BARRIER MUST BE CONSTRUCTED OF
APPROVED MATERIALS. FENCE MUST NOT BE CLIMBABLE AS MEASURED FROM THE OUTSIDE.
OPENING OF BARRIER SHADE MUST NOT ALLOW PASSAGE OF A 4 INCH SPHERE
DWELLING SERVING AS PART OF THE BARRIER SHALL BE EQUIPPED WITH AN ALARM THAT
PRODUCES AN AUDIBLE WARNING. THE ALARM SHALL BE LISTED AND LABELED IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE LOCATED 54 INCHES OR
MORE ABOVE THE THRESHOLD OF THE DOOR.
ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE
AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF
MECHANICAL ENGINEERS (ASME)
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE
VOLTAGE GRADIENTS IN THE POOL AREAS AS PER CEC ART. 680.26
SAFETY FEATURES
ELECTRICAL
GENERAL NOTES
(N) Residence
Scope of work: New Spa and pool
3’
5’
Pool Equipment
Electric
Gas
At least 36” of pipe shall be installed
between the lter and the heater or dedicated
suction and return lines, or built-in or built up connections
shall be installed to allow for the future addition of solar
and heating equipment
A cover for outdoor pools or outdoor spas that have a heat pump
or gas heater
Drainage from the pool shall be retained on-site and
conveyed to well-vegetated surfaces.
Discharge to public street shall not be permitted unless
the collected surface water is
dechlorinated per NPDES MS4 regulations
Existing 6’
Block Wall
Electric panel and
gas meter
Gate Self Latching
Self Closing
81972 Via San Clemente
81972 Via San Clemente
Pool Equipment
Split Drains
3’ apart10’
34’
7’5’
7'-6"
114'
121'
90'
P.L.
P.L.
P.L.
P.L.
10’ PUE
Drawn By Jose Villanueva
7’
21'25'
8'-9"
9'-4"
9'-4"
18” Raised Spa
(N) BBQ
(N) 5’x2’ Firepit
6'
Pool Equipment
Disconnect
Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg
02/23/2024J.ANAYA
BPOL2024-0052
POOL AND SPA, FIRE PIT AT REAR YARD [POOL ENGINEERING]
THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE.
APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING
SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO
DROWNING PREVENTION SAFETY FEATURES AND THE
REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
Digitally signed by Christopher Biedenbach on 02/01/2024 - 1706860800 - 24-00852-dg02/23/2024J.ANAYA