Loading...
BWFE2024-0041 CalcsORCO WALL SYSTEM STRUCTURAL CALCULATIONS PREPARED FOR BEAZER HOMES CANTERA A T CORAL MOUNTAIN TRACT No. 31249 CITY OF LA Q UI N TA, CALIFORNIA ENGINEERING STAMP APPROVAL IS CONDHIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. �1 `iER D UG { Fy �(r r' c NO. 83660 * EXP. 03/3//2025 s�q r C /V ' ,,, OF CAS% +' PREPARED BY ORCO BLOCK & HARDSCAPE 77700 BEACH BLVD STANTON, CA. 90680 TEL. (774) 527-2239 FAX. (774) 897-7904 ORCO WALL SYSTEM FORCES PER 2022 CBC CHAPTER /6 /-A �, TA- aA WIND FORCES TO WALLS PER ASCE 7 SECTION 29.3 CHECK WIND FORCE CALCULATION FOR 3 SECOND GUST SPEED EXPOSURE C CONDITION USING ASCE 7 CHAPTER 29 WIND LOADS 8 USING SECTION 29.3.1 TO FIND THE 3 SEC. VELOCITY PRESSURE OH. QH= 0.00256 KZ KZT KD KE V2... (EQ. 26.10-1), WHERE: KZ = 0.85 FOR EXP C (TABLE 26.10-1), KZT = 1.0 DEFAULT PER SEC. 26.8.2, KD = 0.85 (TABLE 26.6-1) 8 KE = 1.0 PER SECTION 26.9 THEREFORE: 0, = (0.00256) (0.85) 0.0) (0.85) 0.0) V" DESIGN WIND FORCE, FH= OH GCFAS.. (EQ. 29.3-1), WHERE: G= 0.85 FROM SECTION 26.1/.1, AND CF = 1.40 PER FIGURE 29.3-1 USING AVERAGE ASPECT RATIO (WALL LENGTH TO HEIGHT) OF 2. NOTE: CF RANGES FROM 1.48 FOR A 5' WIDE RETURN WALL TO l.3 FOR A 60' PANEL. PROJEC T S/ TE WIND ZONE: V UL T = // 0 MPH EXPOSURE C THEREFORE WIND FORCE =2,(,_ -7- PSF SEISMIC FORCES PER 2022 CBC (ASCE 7 SECT /5.4.18) PROF E S S I QN Iwo y ,ft DI) �c FOR NONBUILD/NG STRUCTURES: - FREE STANDING WALLS AND PILASTERS �. m m m - PROJECT SITE CLASS D Np, 836+50 A - FUNDAMENTAL PERIOD T GREATER THAN 0.06 SEC k Exp- 03/31/2025 CALCULATED USING EQUATION /2.8-7 AND TABLE /2.8-2 srs C I V I %- a�%V AF 4F CA0FO PER EONS. 12.8-1 AND 12.8-2, SEISMIC BASE SHEAR: V= CSW = [SDS/(R11E)) W , WHERE 1E = 1.0 FROM TABLE 1.5-2 8 R = 1.25 FROM TABLE 15.4.2 SEISMIC FORCE SDS 0.40 0.50 0.60 0.70 0.80 0.90 1.00 I. l0 /.20 L,30 /.40 /.50 V 2 [(SDS)1(R11E)1 W 0.32W 0.40W 0.48W 0.56W 0.64W 0.72W 0.80W 0.88W 0.96W 1.04W 1.12W 1.20W PROJEC T S/ TE SEISMIC /NFORMA TION: S DS = /• o & V = A 9 W CMU WALL WEIGHTS PER SQ. FT. (NW) 16,11 CMU WIDTH 6' CMU W1 JOINT REINFORCEMENT 8" CMU L X12 LAS PILASTER PILASTER GROUTED ® 01C 48'01C 40'01C 32'01C 24101C I6'01C SOLID 32101C 24'01C 16'01C SOLID SOLID SOLID WEIGHT 45 PSF 46 PSF I 47 PSF 48 PSF 52 PSF 63 PSF 58 PSF 61 PSF 66 PSF 84 PSF 133 PSF 175 PSF THEREFORE SEISMIC FORCE /S: V = (0.8 )(SZ PSF) = V, (O PSF ORCO CMU SITE WALLS W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C CAP UNIT ORCO 6616 OR 6816 CMU �~ GROUTED ONLY @ VERT STEEL #4 DROP-IN BAR @ 16" O/C C@ CENTER OF CMU NOTE: PROVIDE #4 DOWEL & #4 DROP-IN BAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES #6 STD JOINT REINFORCEMENT * 12" O/C FOR 6616 CMU @ 16" O/C FOR 6816 CMU NOTE: FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURES, A 112 BLOCK MAY LEFT OUT @ SWALE GRADE. PROVIDE #4 DOWEL AND #4 DROP-IN BAR ON EACH SIDE OF THE 112 BLOCK DRAIN. #4 DOWEL @ 16" O/C @ CENTER OF CMU. PROVIDE 24" MIN. LAP. ti f 2 'v 2 1 MAX. • #4 HORZ. CONT. v @ 12" O/C. M SETBACK: 8- AT LEAST THE SMALLEST OF CONT H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #1B DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2 EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI Cal 28 DAYS 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH P, = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 1. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VER7IC4L REBAR SHALL BE SOLID GROUTED. Z USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLEAND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCKSTEM MAYBE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHES ARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL 15 IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS, n BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA %+c.� JEROUG � co A 2�2 a NO. 83660 * EXP. 031JI12025 P s q p C r V` N, a��\ E OF CA`s ORCO CMU SITE WALLS W/ SPREAD FOOTING FOR 110 MPH 3 SEC. GUST Cad EXP C REBAR NOTE: • DO NOT RUN HORIZONTAL REINFORCEMENT THROUGH WALL RETURNS & CONTROL JOINTS. • PROVIDE DOWEL & DROP-IN BAR ACCORDING TO DETAIL AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES. O N ORCO 6616 OR 6816 CMU GROUTED ONLY @ VERT STEEL #4 - DROP-IN BAR @ 16" O/C @ CENTER OF CMU #6 STD JOINT REINFORCEMENT @ 12" O/C FOR 6616 CMU * 16" O/C FOR 6816 CMU #4 DOWEL @ 16"01C @ CENTER OF CMU. PROVIDE 24" MIN. LAP. SETBACK: AT LEAST THE SMALLEST OF H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #1A DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH, f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 1. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE IIIV. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60, PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USINGA5TM C 170 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS: 9. BLOCK STEM MAY BE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 11. MAXIMUM CONTROL JOINT SPACING: 20'01C. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA day/2��ZoZ3�� N0.83660 D * EXP. 0JI3112025 T 5 F OF CA `�F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LiC# : KW•66016003. 13411¢:20.23.2,14 OAK COMPANY INC DESCRIPTION: (01a) Site Wall Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height Wall height above soil - Slope Behind Wall = Height of Soil over Toe = Water height over heel 0.33 ft 6.67 ft 0.00 4.00 in 0.0 ft Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore Spread Footing for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 277.3 #/ft ...Height to Top = 5.28 It ...Height to Bottom = 4.28 It Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazer homes_cantera_la quinta.ec6 l[:1 E_NE'lG U-1 IN[; Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall _ 0.0 ft - Poisson's Ratio = 0.300 QRp>:ESSr�N� w4wa yeRDUGO• i. y ti A COa uX11 m NO 83660 yr EXP 03/31/2025 S+ r C / V i 4a\P F OF CALF❑ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC1i : KW -06016603. BuIld:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (01 a) Site Wall Project File: beazer homes _cantera_la quinta.ec6 (c} ENERCALC INC 1963.2022 ASD 4ROFESS 1p7 �¢�q JER�UG0 �v Dern NO 83660 EXP 03/31/2025 yE U v P DF CALIF❑ Design Summary Stem Construction Bottom — Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Overturning = 1.24 Ratio < 1.5! Design Method = SD Sliding _ 1.93 OK Thickness = 6.00 Global Stability - 4.92 Rebar Size = # 4 Rebar Spacing = 16.00 Total Bearing Load = 924 lbs Rebar Placed at = Center d iW ...resultant ecc. = 14.43 in Design Data \ Eccentricity outside middle third fb/FB + fa/Fa = 0.769 Soil Pressure @ Toe 2,037 psf OK Total Force @ Section Soil Pressure @ Heel 0 psf OK Service Level lbs = i Allowable = 2,667 psf Soil Pressure Less Than Allowable Strength Level Moment.... Actual lbs= 280.4 ACI Factored @ Toe 2,851 psf Service Level ft-#= ACI Factored @ Heel = 0 psf Strength Level ft-#= 1,326.0 Footing Shear @ Toe = 8.1 psi OK Moment..... Allowable = 1,722.7 Footing Shear @ Heel = 2.5 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = Sliding Calcs Strength Level psi = 8.0 Lateral Sliding Force = 225.1 lbs Shear..... Allowable psi = 80.5 less 100% Passive Force - 64.8 lbs Anet (Masonry) in2 = 35.07 less 100% Friction Force s - 369.5 lbs Wall Weight psf = 52.0 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 2.81 ....for 1.5 Stability = 0.0 lbs OK Masonry Data Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fy psi = 60,000 Solid Grouting = No Load Factors Modular Ratio 'n' = 16.11 Building Code Equiv. Solid Thick. in= 4.11 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = SD Earth, H 1.600 Concrete Data _- Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi= ASD 4ROFESS 1p7 �¢�q JER�UG0 �v Dern NO 83660 EXP 03/31/2025 yE U v P DF CALIF❑ Cantilevered Retaining Wall LION - KW -06016003. Build:20.23.2.14 DESCRIPTION: (01 a) Site Wall Footing Data Toe Width = 1.25 ft Heel Width = 1.75 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 240 ft-# 240 ft-# OK ,500 ft-# 2.54 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area Toe Heel Factored Pressure = 2,851 Mu': Upward = 1,212 Mu': Downward = 212 Mu: Design = 1,001 OK phiMn = 2,500 2 Actual 1 -Way Shear = 8.10 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 240 ft-# 240 ft-# OK ,500 ft-# 2.54 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft if one layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in eRaFe55+oHa ¢w9 Ire .m. IW DIA. NO. 83660 * EXP. 03/31/2025 ,p�glFC fV%1. aR�r OF CAL IF Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File., beazer homes_cantera_la quinta.ec6 LEG# : Kw-mb16003. 8uIId:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENEACALC INC 1983.2022 DESCRIPTION: (01 a) Site Wall Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# HL Act Pres (ab water tbl) 31.0 0.44 13.7 Soil Over HL (ab. water tbl) 47.4 2.38 112.7 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.38 112.7 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = 194.1 5.78 1,122.1 ' Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 47.9 0.63 29.9 Surcharge Over Toe = Stem Weight(s) = 364.0 1.50 546.0 Earth @ Stem Transitions= Total = 225.1 O.T.M. = 1,135.8 Footing Weight = 450.0 1.50 675.0 Key Weight = Resisting/Overturning Ratio = 1.24 Vert. Component = 14.3 3.00 42.9 Vertical Loads used for Soil Pressure = 923.6 lbs Total = 923.6 lbs R.M.= 1,406.5 " Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.220 in The above calculation Is not valid if the lie eI soil ea ri nq pressure exceeds that at the toe because the wall would then tend to rotate into the retained soil. QROFESS /pN ��¢rti9 .1EROt1C 4 Fc w 01M NO 83660 D * EXP 03/31/2025 Jar C, I V qYE OF CnL,404 TRENCH FOOTING OVERTURNING AND SLIDING CHECK OVERTURNING WALL DIMENSIONS SEISMIC HF = 7 ft Freestanding height (TF to TW) input BF = 0.5 ft Freestanding portion width input FTGp = 3.5 ft Footing depth input FTGW = 0.67 ft Footing width input c = 0.33 ft Footing cover input HE = 6.67 ft Exposed height of wall MFT = CS = 0.8 Moment due to footing self weight RESISTING MOMENT Self weight of wall WTF = 52 psf Freestanding wall weight per sq.ft. input WF = WTF (HF - c)= 346.84 plf Freestanding wall weight per ft of wall MF = WF FTGW/2 = 116.1914 ft -Ib Moment due to freestanding wall self weight WTFT = 150 pcf (FTGW) = 100.5 psf Footing weight per sq.ft. wFT = WTFT FTGp = 351.75 plf Footing weight per ft of wall MFT = wFT FTGW/2 = 117.8363 ft -Ib Moment due to footing self weight Self weight of soils on top of footing WTS = 115 pcf WS/FT= WTS (FTGW BF) c = 6.45 plf MS= WS/FT * FTGW/2 = 2.16 ft -Ib Passive Pp = 250 psf/ft Dig = 1 ft PPP = 0.5 Pp (FTGpz - Dig): 1,708.61 Ib h = 2.83 ft Y= 1.19 ft MPP = PPP y = 2,032.62 ft -Ib Resisting Moment MR= MF+MFT+MPP+MS = 2,268.81 ft -Ib OVERTURNING MOMENT Unit weight of soil input Weight of soil on top of footing per ft Moment due to soil self weight (on top of footing) Ultimate passive pressure (increased 1/3 for s input Depth to ignore passive input Passive resistance depth of Passive Resistance triangle or trapezoid Vert. distance of centroid of triangle/trapezoid, from bot Moment resistance (passive) - Seismic Vs = CS (WF) = 277.472 plf Seismic Load Mv, = Vs * (2/3*HE + c + F- 2296.543 ft -Ib Moment MOTs = 0.7Mv, = 1,607.58 ft -Ib per CBC 1807.2.3 - Active pressure EFP = 35 pcf Equivalent fluid pressure Pa = 0.5 EFP (FTGp + c)z 256.71 Ib Active load input Mora = Pa (FTGp + c)/3 327.73 ft -Ib Overturning moment due to active pressure Overall Overturning moment MOT = MOTs + MOTa = 1,335.31 ft -Ib FACTOR OF SAFETY "OVERTURNING" SEISMIC FSOTs = MR / Mors = 1.17 > 1.1 OK Check SLIDING FC = 0 Soil Friciton Coefficient input SLIDING RESISTANCE Self weight of wall SRF = FC WF = 0 Ib Sliding resistance due to CMU freestanding portion SRFT = FC WFT = 0 Ib Sliding resistance due to Concrete footing Self weight of soil on top of footing SRS = FC WS/FT = - Ib Sliding resistance due soil on top of footing Passive PPP = 1,708.61 Ib Passive resistance Sliding Resistance SR = SRF + SRR + SRFT + + SRS + PPP = 1,708.61 Ib SLIDING FORCES Seismic ....... 0.7 Vs = 194.23 lb ;.•� `_ (�,� 19 U Active pressure P — 256.71 Ib E• n, ri Pa (9 ` ti 4 r Total sliding force e+ti q ' SF = 0.7 Vs + Pa = Ib FACTOR OF SAFETY "SLIDING" Seismic FSS, = SR / SF = 3.79 > 1.1 OK ORCO 12" SQ. PILASTER FOR 110 MPH 3 SEC. GUST @ EXP C DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH Pm = 2000 PSI. r sl I ►A: CAP UNIT ORCO 12612 PILASTER CMU SOLID GROUTED. SEE DIAGRAM BELOW #4 VERT. DROP-IN BAR #4 DOWEL W/ 24' MIN. EXTENSION INTO CMU J #4 HORZ 0 9' 0/C EACH WAY GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE ILIV. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60, PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A STACK BOND PATTERN. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS 9. BLOCK STEM MAY BE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHESARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACEAND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHERE INTERSECTION BLOCK WALLS OCCUR. EOUAL ORCO 12612 PILASTER CMU 2 (SOLID GROUTS[ F v 2 1 MAX. 3'-0" SQUARE FOOT/NG NOTE ONLY RUN WALL FOOT/NG HORIZONTAL REINFORCEMENT THROUGH PILASTER FOOTING, WHEN INTERSECTING. DETAIL #2 SETBACK.• AT LEAST THE SMALLEST OF H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT #4 VERTICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO SC4LE ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. ¢�10 -4 ftDUGO 4 c BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 / g �Zo2 3 D LA QUINTA, CALIFORNIA N0. 83660 * EXP. 03/3//2025 1.6LOTE: DIMENSIONS ARE NOT TO SCALE. `�'*4 c J V ` lF OF CAL�Fq¢ Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (02) Pilaster Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 0.33 ft Wall height above soil = 7.33 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel — 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Project Title: Engineer: Project ID: Project Descr: Project File: beazerhom6s_c..antenk la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore (Strength Level) for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 260.1 #/ft ...Height to Top = 5.72 ft ...Height to Bottom = 4.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) r Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.300 QROFESS/flN. �4wo yrGRp!!g Q 0c ti� cl 4r wl �m � D A NO 83660 * EXP 03/31/2025 T4 CIV�1 lF OF c4k-'F O4 Cantilevered Retaining Wall I.104 : KW -66016003. BuIU20.2.3.2.14 DESCRIPTION: (02) Pilaster Project Title: Engineer: Project ID: Project Descr: Project File: beazer homes_cantera—la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Sliding Calcs Lateral Sliding Force = less 100% Passive Force » less 100% Friction Force - Added Force Req'd = ....for 1.5 Stability = Design Summary Building Code Stem Construction 213.0 lbs Shear..... Allowable 64.8 lbs Design Height Above Ftg 350.7 lbs Wall Stability Ratios 0.0 lbs OK Wall Material Above "Ht" 0.0 lbs OK Overturning = 1.17 Ratio < 1.5! Design Method Sliding 1.95 OK Thickness Global Stability = 3.71 Rebar Size Rebar Spacing U Total Bearing Load = 877 lbs Rebar Placed at Design Data ...resultant ecc. = 15.36 in 0 Eccentricity outside middle third fb/FB + fa/Fa .L; Soil Pressure @ Toe = 2,610 psf OK Total Force @ Section ►'F Soil Pressure @ Heel 0 psf OK Service Level Allowable — 2,667 psf Strength Level Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe 3,653 psf Service Level ACI Factored @ Heel = 0 psf Strength Level Footing Shear @ Toe = 8.1 psi OK Moment..... Allowable Footing Shear @ Heel = 2.1 psi OK Allowable = 75.0 psi Shear.....Actual Sliding Calcs Lateral Sliding Force = less 100% Passive Force » less 100% Friction Force - Added Force Req'd = ....for 1.5 Stability = Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Service Level Building Code Strength Level 213.0 lbs Shear..... Allowable 64.8 lbs Anet (Masonry) 350.7 lbs Wall Weight 0.0 lbs OK Rebar Depth 'd' 0.0 lbs OK 1.000 Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Masonry Data f'm Fs Solid Grouting Modular Ratio'n' Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data f'c Fy 'Bottom Stem OK ft= 0.00 Masonry ASID 12.00 _ # 4 16.00 Center 0.442 lbs= 184.0 lbs = ft-# = 950.6 ft-# = 2,146.1 psi = 1.3 psi = psi = 51.0 int = 139.50 psf = 43.9 in= 5.81 psi = 2,000 psi = 32,000 Yes 16.11 in= 11.63 psi = psi = ASD QROFESSIQNQ ti 2• fi-o. % , m � D A NO. 83660 * EXP 03/31/2025 {qr CIVIC- 4A�P OF CN0 Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (02) Pilaster Footing Data Toe Width = 1.00 ft Heel Width = 2.00 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth - 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Footing Design Results Project File: beazar homescantera_!a qulnta.ec6 (c) ENERCALC INC 1983-2022 Toe: phiMn = ph'S`lambda'sgrt(fc)" Sm Heel: phiMn = ph`5`lambda`sgrt(fc)'Sm Key: No key defined 0 psf 0 ft-# 192 ft-# 192 ft-# OK ,500 ft-# 2.07 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area Toe Heel Factored Pressure = 3,653 Mu': Upward = 941 Mu': Downward = 170 Mu: Design = 772 OK phiMn = 2,500 2 Actual 1 -Way Shear = 8.05 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceatahle Sizes & Snacinas Toe: phiMn = ph'S`lambda'sgrt(fc)" Sm Heel: phiMn = ph`5`lambda`sgrt(fc)'Sm Key: No key defined 0 psf 0 ft-# 192 ft-# 192 ft-# OK ,500 ft-# 2.07 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one laver of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in QROFESS ION ,SRDUG �� ua, QI SS4' m NO 83660 * EXP 03/31/2025 �4r C I V tL ¢ttio R Ox C4L %% Cantilevered Retaining Wall LICH - KW -06016003, 131fiId'20.23- A4 DESCRIPTION: (02) Pilaster Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item lbs It ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 31.0 0.44 182.1 6.22 13.7 1,132.4 Total 213.0 O.T.M. = 1,146.2 Resisting/Overturning Ratio = 1.17 Vertical Loads used for Soil Pressure = 876.8 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983.2022 ...RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 38.0 2.50 94.9 Soil Over HL (bel, water tbl) 2.50 94.9 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = 38.3 0.50 19.2 Surcharge Over Toe = Stem Weight(s) = 336.2 1.50 504.3 Earth @ Stem Transitions= Footing Weight = 450.0 1.50 675.0 Key Weight = Vert. Component = 14.3 3.00 42.9 Total = 876.8 lbs R.M.= 1,336.2 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Tol) of Wall due to settlement of soi (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Deft @ Top of Wall (approximate only) 0.308 in The above calculation is not valid ii the heel soil bearing pressure exceeds that of the tom, because the wall would then tend to rotate into the retained soil. QpOFESSlOti4 �0 'IeRDU17 Fs v it a D1A� N0. 83660 * EXP 03/31/2025 sr C f V OF cA04 ORCO CMU + T. S. FENCE W/ SPREAD FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. ti I CONT. 4S SHOWN oe SETBACK: v Z-2" AT LEAST THE SMALLEST OF ;h H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT ENGINEERING STAMP APPROVAL IS CONDITIONAL; NOTE: DIMENSIONS ARE NOT TO SCALE. REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DETAIL �a ,eR D UG 4c BEAZER H01" y �-a s GANTERA @ CORAL MOUNT " m TRACT No. 31249 y�t LA QUINTA, CALIFORNIA NO. 83660 * EXP. 0313112025 P2gT C , V IN, � `P F Op CA01Q vi GENERAL 1. 2. NOTES: CONCRETE BLOCK SHALL BE MANUFACTURED BYORCO ASTM C 90. NORMAL WEIGHT. CONCRETE FOR FOOTING SHALL BE I PART CEMENT TO 1-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM mC 150 TYPE II/V. Fc = 1500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A . U 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. c O 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOG4TED. p p m 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH N W VERTICAL CONTINUITY OF THE CELLS UNO. Wti 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID Z ----i Z GROUTED. #4 HORZ. CONT. @ h Wp 7. TOP BOND BEAM USE TYPES MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. II (ORPENCIL RODS). a 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT l j #4 DOWEL 0) 32" O/C FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW ti @CENTER OF CMU. WITHOUT SEGREGATION OF THE CONSTITUENTS h 9. BLOCK STEM MAY BE WET -SET 1 -112 -INTO THE FOOTING WHILE THE WCONCRETE 101,OF IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE U �o I� THE TRENCH TYPE FOOTING. o�p > #4 HORZ CONTT, 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL b O 2 @ 24" O/C OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. O p p Il. FIRST INSPECTION TO BEAFTER FOOTING TRENCHES ARE READY FOR fEQUAL EQUAL CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND + INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND ° THE BLOCK WALL 15 READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. ti I CONT. 4S SHOWN oe SETBACK: v Z-2" AT LEAST THE SMALLEST OF ;h H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT ENGINEERING STAMP APPROVAL IS CONDITIONAL; NOTE: DIMENSIONS ARE NOT TO SCALE. REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DETAIL �a ,eR D UG 4c BEAZER H01" y �-a s GANTERA @ CORAL MOUNT " m TRACT No. 31249 y�t LA QUINTA, CALIFORNIA NO. 83660 * EXP. 0313112025 P2gT C , V IN, � `P F Op CA01Q ORCO CMU + T.S. FENCE W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 150 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. SETBACK.' AT LEAST THE SMALLEST OF GENERAL 1, NOTES: CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. REQUIRING USE OF ORCO MANUFACTURED CMU ON WHERE H = SLOPE HEIGHT = ti NOTE: DIMENSIONS ARE NOT TO SCALE. � 4 [ NORMAL WEIGHT. �.1pRDUG BEAZER HOAfeS, O 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS m N0. 83660 LA QUINTA, CALIFORNIA * EXP. 0313112025 SAND TO 3-1/1 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS j syr C 1 V ' OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM O U C 150 TYPE II/V. Fc = 2500 PSI 00 OF� @� 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A O615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. g m 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ^� W IT IS LOCATED. U ti 5. CONCRETE BLOCK SHALL BE LAID INA RUNNING BOND PATTERN WITH 2 VERTICAL CONTINUITY OF THE CELLS UNO. #4 HORZ. CONT. @a WQ TOP BOND BEAM 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID 5 (OR " PENCIL RODS). GROUTED. Z USE TYPES MORTAR PROPORTIONED USING ASTM C270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. • 8. GROUT FOR CONCRETE BLOCK PER ASTM C476 TO BE 1 PART W #4 DOWEL @ 32" O/C CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA @ CENTER OF CMU. GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT J FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW V j WITHOUT SEGREGATION OF THE CONSTITUENTS. b Q #4 HORZ CONT. 9. BLOCKSTEM MAYBE WET -SET 1-1/1" INTO THE FOOTING WHILE THE op > CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE b 62 @ 24" O/C OF THE TRENCH TYPE FOOTING. O O W 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL j $ OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 2 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR MAX. 1 CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. • #4 HORZ. CONTT, 11. MAXIMUM CONTROL JOINT SPACING: 20'01C. _ @ 10" O/C O 0 M 3" CLR. SETBACK.' AT LEAST THE SMALLEST OF ENGINEERING STAMP APPROVAL IS CONDITIONAL; 10„ H/3 AND 40 FT (7 FT MIN.), REQUIRING USE OF ORCO MANUFACTURED CMU ON WHERE H = SLOPE HEIGHT ALL ORCO WALL SYSTEM DESIGNS. NOTE: DIMENSIONS ARE NOT TO SCALE. � 4 [ �.1pRDUG BEAZER HOAfeS, DETAIL #3B cANTER4 �a CORAL MOUNTAIN "Q /�9/Zozs a m y A TRACT No. 31249 D N0. 83660 LA QUINTA, CALIFORNIA * EXP. 0313112025 syr C 1 V ' ❑4��a F OF CA`�F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera—la quinta.ec6 LICH : Kw -08016003. Build:20.23.2.14 0406 OLOCK COMPANY INC (c) ENERCALG INC 1983.2022 DESCRIPTION: (03) View fence Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data I Retained Height = 0.33 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 5.17 ft Equivalent Fluid Pressure Method Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft + Soil Density, Heel = 115.00 pcf i Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load Surcharge Over Heel — 0.0 psf Lateral Load = 0.0 #/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding & Overturning Load Type = Wind (W) Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem (Strength Level) Footing Type Spread Footing Base Above/Below Soil = 0.0 ft Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 26.7 psf at Back of Wall Axial Live Load = 0.0 lbs (Strength Level) Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Qa0FESSIO y �,w° yrGRouc �, 0 q) STI m D N0. 83660 . * EXP. 03/31/2025 s�qr C I'V `� Fa~P Cantilevered Retaining Wall LIC# : KW -06016003, Build: 20.23.2.14 DESCRIPTION: (03) View fence Design Summary Wall Stability Ratios Overturning - 1.97 OK Sliding = 2.68 OK Global Stability 4.52 Total Bearing Load = 600 lbs ...resultant ecc. = 6.29 in Eccentricity outside middle third Soil Pressure @ Toe = 698 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 977 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 3.2 psi OK Footing Shear @ Heel = 1.4 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 113.7 lbs less 100% Passive Force - 64.8 lbs less 100% Friction Force = 239.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 Stability = 0.0 lbs OK Project Title: Engineer: Project ID: Project Descr: Project Flle: bearer homes cantera_la qulnta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Stem Construction Masonry Data Design Height Above Ftg ft= Wall Material Above "Ht" _ Design Method = Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data Modular Ratio'n' fb/FB + fa/Fa = Total Force @ Section Equiv. Solid Thick. Service Level lbs = Strength Level lbs = Moment.... Actual Service Level ft-# _ Strength Level ft-# _ Moment..... Allowable ft -4 _ Shear..... Actual Service Level psi = Strength Level psi = Shear..... Allowable = Anet (Masonry) in2 = Wall Weight psf = Rebar Depth 'd' in= 2nd Bottom _ Stem OK 3.50 0.00 Fence Masonry ASD ASD 8.00 # 4 32.00 Center 0.339 32.0 84.7 31.9 241.4 710.4 3.6 51.6 23.77 58.0 3.81 QEypFES$/ON4 4eRDUGO t �C m M. aI� NO 83660 EXP. 03/31/2025 kP�qr C I V F 4F CA% -%I Masonry Data - Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = No Load Factors Modular Ratio'n' = 16.11 Building Code Equiv. Solid Thick. = 4.48 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi= QEypFES$/ON4 4eRDUGO t �C m M. aI� NO 83660 EXP. 03/31/2025 kP�qr C I V F 4F CA% -%I Cantilevered Retaining Wall LIDO: KW -06016003, Bultd:20.23Z14 DESCRIPTION: (03) View fence Footing Data Toe Width = 0.75 ft Heel Width 1.42 Total Footing Width s 2.17 Footing Thickness = 12.00 in Key Width - 0.00 in Key Depth 0.00 in Key Distance from Toe - 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1963-2622 Toe Heel Factored Pressure = 977 Mu': Upward = 234 Mu': Downward = 92 Mu: Design = 142 OK phiMn = 2,500 2 Actual 1 -Way Shear = 3.23 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceotable Sizes & Soacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 2 ft-# 109 ft-# 107 ft-# OK ,500 ft-# 1.44 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.56 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one layer of horizontal tsars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in egoFESS10V4 ERDUG w� M �. 1 0 N0. 83660 D A * EXP 03/31/2025 .P�qT C , V � L F Op CALM Cantilevered Retaining Wall LJCP : KW -06016003, Build:20.23.2.14 DESCRIPTION: (03) View fence Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item lbs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load Q Stem Above Soil = 31.0 0.44 82.8 3.91 Total 113.7 O.T.M. = Resisting/Overturning Ratio = 1.97 Vertical Loads used for Soil Pressure = 599.6 lbs Project File: beazer homes_cantera_laquint (c) ENERCALC INC 1983-2022 ...RESISTING...., Force Distance Moment Ibs ft ft-# 13.7 Soil Over HL (ab. water tbl) 28.5 1.79 51.0 Soil Over HL (bel. water tbl) 1.79 51.0 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = 323.9 Soil Over Toe = 28.8 0.38 10.8 Surcharge Over Toe = Stem Weight(s) = 203.0 1.08 219.9 Earth @ Stem Transitions= 337.7 Footing Weight = 325.1 1.08 352.2 Key Weight = Vert. Component = 14.3 2.17 31.0 Total = 599.6 lbs R.M.= 664.9 " Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl Q Top of Wall (approximate only) 0.082 in The above calculation is not valid If the heel soil bearing ressure extends that of the Ioa because the wall would then tend to rotate into the retained soil. QRQFESS/ON4 le ygRDtJr;O ��eFc w � m Fit m NO 83660 EXP 03/31/2025 4r C/V 1\-t- F OF C A0F TRENCH FOOTING OVERTURNING AND SLIDING CHECK (view wall) OVERTURNING WALL DIMENSIONS 150 pcf (FTGW) = 124.5 psf WFT = HF = 5.5 ft Freestanding height (TF to TW) input BF = 0.67 ft Freestanding portion width input FTGp = 3 ft Footing depth input FTGW = 0.83 ft Footing width input C = 0.33 ft Footing cover input HE = 5.17 ft Exposed height of wall WIND WL = 26.7 psf RESISTING MOMENT Self weight of wall WTF = 46 psf Freestanding wall weight per sq.ft. input WF = WTF (HF - c)= 237.82 plf Freestanding wall weight per ft of wall MF = WF FTGW/2 = 98.6953 ft -Ib Moment due to freestanding wall self weight WTFT = 150 pcf (FTGW) = 124.5 psf WFT = WTFT FTGp = 373.5 plf MFT = WFT FTGW/2 = 155.0025 ft -Ib Self weight of soils on top of footing WTS = 115 pcf WS/FT= WTS (FTGW-BF) c = 6.07 plf MS = WS/FT * FTGW/2 = 2.52 ft -Ib Passive Pp = 250 psf/ft Dig = 1 ft PPP = 0.5 Pp (FTG '2 - Di'2)= 1,261.11 Ib h= 2.33 ft Y= 1.01 ft MPP = PPP y = 1,273.60 ft -Ib Resisting Moment MR = MF+MFT+MPP+MS = 1,529.82 ft -Ib OVERTURNING MOMENT Footing weight per sq.ft. Footing weight per ft of wall Moment due to footing self weight Unit weight of soil input Weight of soil on top of footing per ft Moment due to soil self weight (on top of footing) Ultimate passive pressure (increased 1/3 for s input Depth to ignore passive input Passive resistance depth of Passive Resistance triangle or trapezoid Vert. distance of centroid of triangle/trapezoid, from bot Moment resistance (passive) - Wind W = WL * HE = 138.039 plf Wind Load MW = WL * (0.55*HE + c + 852.1838 ft -Ib Moment MOTW = 0.6MW = 511.31 ft -Ib - Active pressure EFP = 35 pcf Equivalent fluid pressure input Pa = 0.5 EFP (FTGp + c)Z 194.06 Ib Active load Mora = Pa (FTG, + c)/3 215.40 ft -Ib Overturning moment due to active pressure Overall Overturning moment MOT = MOTw + MOTa = 726.71 ft -Ib FACTOR OF SAFETY "OVERTURNING" SEISMIC FSOT, = MR / MOTs = 2.11 > 1.1 OK Check SLIDING FC = 0 Soil Friciton Coefficient input SLIDING RESISTANCE SRF = FC WF = 0 Ib Sliding resistance due to CMU freestanding portion SRFT = FC WFT = 0 Ib Sliding resistance due to Concrete footing Self weight of soil on top of footing SRS = FC WS/FT = Ib Sliding resistance due soil on top of footing Passive PPP = 1,261.11 Ib Passive resistance Sliding Resistance SR = SRF + SRR + SRFT + + SRS + PPP = 1,261.11 Ib SLIDING FORCES Seismic 0.7 Vs = 96.63 Ib Active pressure Pa = 194.06 Ibwt'w,� i Total sliding force SF= 0.7 Vs+Pa= �lb ati "SLIDING" 4' FACTOR OF SAFETY Seismic FSSL, = SR / SF = 4.34 > 1.1 OK ORCO 6' HIGH WALL W/ RETAINING & SPREAD FOOTING FOR 110 MPH WIND 3 SEC. GUST @ EXP C SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRYSTEM. GAP UNIT ORCO 6616 CMU GROUTED ONLY @ VERT STEEL #4 DROP-IN BAR @32" O/C. PROVIDE 24" LAP INTO 8" CMU. #6 STD JOINT c REINFORCEMENT b @ 12" O/C NOTE: PROVIDE #4 DOWEL & #4 DROP-IN BAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND 0 WALL HEIGHT CHANGES LEVEL BACKFILL COMPACTED #4 HORZ. CONT. TO MIN. 90% COMPACTION @ 24" o/C PER ASTM 1557-D 2 O 'B' —1 FCLR. ' r i-""--1 I I— 2'-0" 2'-6" N/A #4@32" 0/C 33" l3 D' DOWEL CK 6" 3'-0" 4" DIA. SOR 35 PERF PIPE b0 O F #4@16" 0/C 21" W/1FT WIDE OF}" GRAVEL WRAPPED W/ 8.-16" FI MIRA14ON FILTER 4'-0" b 4" FABRIC 70 WITHIN 1 FT OF #4@l6" 0/C 24" FG - SLOPE TO DRAIN. x;l _ 5'-0" WATERPROOF BACKSIDE _-_ 1 #408" O/C 69" #4@8" O/C 30" OF RETAINING WALL. 8"� 2" CLR. fE'BAR 7TO DAYLIGHT #4 HORZ. CONT. 0 12" O/CAS SHOWN 6' NOTE: DIMENSIONS ARE NOT TO SCALE. 'A' 'B' 'C' 'D' DOWEL IF BAR 2'-0" 2'-6" N/A #4@32" 0/C 33" #4@32" O/C /8" 8" J 6" 3'-0" 2'-9" N/A #4@16" 0/C 45" #4@16" 0/C 21" 8.-16" 4'-0" 3'-0" 4" #4@16" O/C 57" #4@l6" 0/C 24" 8" J 8" 5'-0" 3'-6" 7" #408" O/C 69" #4@8" O/C 30" 8"� 8" DESIGN CRITERIA PER THE 1022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3, ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE 11/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ITIS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. Z USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. DETAIL #4 ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. �1 BE.42ER HOMES ` CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA //4.c4vr�RDi1G +� �,c NO. 83660 * EXP. 03/3l/2025 Q F OF CA��F Cantilevered Retaining Wall UGN : KW-M160a3, Build:20.23.2.14 DESCRIPTION: (04a) 2' ret with top out Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height Wall height above soil = Slope Behind Wall = Height of Soil over Toe = Water height over heel = Surcharge Loads Project Title: Engineer: Project ID: Project Descr: Project File: beazer homes_cantera_la quinta.ec6 1 -oRCO BLOCK compmy INC (c) ENERCALC INC 1983-2022 1 Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = Soil Data ...Height to Top = r 2.00 ft Allow Soil Bearing = 2,666.6 psf Seismic (E) 6.33 ft Equivalent Fluid Pressure Method Wind on Exposed Stem = 0.0 psf Active Heel Pressure = 35.0 psf/ft Poisson's Ratio 0.00 6.00 in = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf ,- FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 6.72 ft ...Height to Bottom = 5.72 ft Load Type = Seismic (E) Footing Type (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Adjacent Footing Load Adjacent Footing Load = 1,500.0 lbs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil = -1.5 ft at Back of Wall Poisson's Ratio - 0.300 ea0fESS 10,V 41��° 3ER❑t1c F?. c� r�i1 m n1A NO 83660 * EXP 03/31/2025 V F OF CA`\FD Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LICA - KW -06016003, SuiEd:20.23.2A41 00(-,0 9LaCK COMPANY INC (c) ENEFICALC INC 1383-2022 DESCRIPTION: (04a) 2' ret with top out Design Summary Stem Construction 2nd Bottom Stem OK StemOK Design Height Above Ftg ft= 2.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.53 OK Design Method = ASD ASD Sliding = 2.09 OK Thickness = 6.00 8.00 Global Stability = 3.78 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 32.00 Total Bearing Load = 1,176 lbs Rebar Placed at = Center Edge ...resultant ecc. = 10.02 in Design Data Eccentricity outside middle third fb/FB + fa/Fa = 0.846 0.703 Soil Pressure @ Toe = 1,891 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs = 104.2 174.2 Allowable = 2,667 psf Strength Level lbs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 2,647 psf Service Level ft-# = 439.9 694.9 ACI Factored @ Heel = 0 psf Strength Level ft-# = Footing Shear @ Toe = 7.7 psi OK Moment..... Allowable ft-# = 518.6 987.8 Footing Shear @ Heel = 5.0 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 1.9 Sliding Calcs Strength Level psi = Lateral Sliding Force = 274.8 lbs Shear..... Allowable psl = 52.5 52.0 less 100% Passive Force 104.2 lbs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force - 470.4 lbs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 2.81 5.25 ....for 1.5 Stability = 0.0 lbs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 32,000 Solid Grouting W No Yes Load Factors Modular Ratio'n' - 16.11 16.11 Building Code Equiv. Solid Thick. in= 3.39 7.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = PROFESS/4N ¢�4 �EVZDUG ,4 . m rrn . Iw O 1 m � A NO 83660 D * EXP 03/31/2025 srgr C I V 1\ ¢t1 v F or CAL '10 Cantilevered Retaining Wall LIGN : KW -06016003, f3ui[d:20.23.?.1 DESCRIPTION: (04a) 2' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 2.00 Total Footing Width = 2.50 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la qulnta.ec6 (c) ENERCALC 1NC 1983-2022 Toe Heel Factored Pressure = 2,647 Mu': Upward = 287 Mu': Downward = 52 Mu: Design = 235 OK phiMn = 2,500 2 Actual 1 -Way Shear = 7.68 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Soacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 507 ft-# 507 ft-# OK ,500 ft-# 5.01 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.65 in2 Min footing T&S reinf Area per foot 0.26 in2 ift It one laver of horizontal bars: If two layers of horizontal bars- #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in QpOFESS ION y�v w� dim N0. 83660 * EXP 03/31/2025 Sr C 1 V 4TE OF GA��F�¢ Cantilevered Retaining Wall LICK: Kw -46016603, Bulld:20.23.2.14 DESCRIPTION: (04a) 2' ret with top out Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item lbs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 157.5 1.00 13.2 0.29 104.2 7.22 Total 274.8 O.T.M. = Resisting/OverturnIng Ratio = 1.53 Vertical Loads used for Soil Pressure = 1,175.9 lbs Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 .....RESISTING ..... Force Distance Moment lbs ft ft-# 157.5 Soil Over HL (ab. water tbl) 306.7 1.83 562.2 Soil Over HL (bel. water tbl) 1.83 562.2 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = 3.8 Axial Dead Load on Stem = 752.4 Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.2 Surcharge Over Toe = Stem Weight(s) = 465.5 0.78 363.1 Earth @ Stem Transitions= 913.7 Footing Weight = 375.0 1.25 468.8 Key Weight = Vert. Component Total= 1,175.9 lbs R.M.= 1,401.3 ` Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.292 in The above calculation is not valid if II1e heel soli bea ri no pMsure exceeds that of the toe because the wall would then tend to rotate into the retained soil. QRpFE55/ONS y � NO 83660 D * EXP 03/31/2025 C V OF C1,0 Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (04b) 3' ret with top out Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height Wall height above soil - Slope Behind Wall - Height of Soil over Toe - Water height over heel = Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = Soil Data ...Height to Top = 3.00 ft Allow Soil Bearing = 2,666.6 psf 6.33 ft Equivalent Fluid Pressure Method Wall to Ftg CL Dist = Active Heel Pressure = 35.0 psf/ft 0.00 (Strength Level) at Back of Wall 6.00 in Poisson's Ratio = = 0.0 ft Passive Pressure 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure - 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 7.72 ft ...Height to Bottom = 6.72 ft Load Type = Seismic (E) Wall to Ftg CL Dist = (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) at Back of Wall Project File: Beazer homes ,cantera_ la qu1nta.ec6 (c) ENERCALC INC 1983-2022 Adjacent Footing Load Adjacent Footing Load = 1,500.0 lbs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil = -1.5 ft at Back of Wall Poisson's Ratio = 0.300 QgOFESS/ON UG wf� m m NO 83660 * EXP. 03/31/2025 s� CfV`L 9rF Op G A411 44 Cantilevered Retaining Wall LIClt : KW -M16003, Build:20.23 2.14 DESCRIPTION: (04b) 3' ret with top out Design Summary Wall Stability Ratios Overturning - 1.64 OK Sliding = 1.64 OK Global Stability = 3.26 Total Bearing Load = 1,537 lbs ...resultant ecc. = 10.17 in Eccentricity outside middle third Soil Pressure @ Toe = 1,942 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,718 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 8.4 psi OK Footing Shear @ Heel = 6.6 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 439.2 lbs less 100% Passive Force - 104.2 lbs less 100% Friction Force = - 614.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 Stability = 0.0 lbs OK Project Title: Engineer: Project ID: Project Descr: Project Fife: beazer homes-cantera_la quinta.ec6 ORCO BLOCK COMPANY INC [c] ENERCALC INC 1983-2022 Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment ..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' 2nd Masonry Data Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs = Masonry Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data Wind, W 1.000 f'c Seismic, E 1.000 Fy 2nd Bottom Stem OK Stem OK ft = 3.00 0.00 = Masonry Masonry - ASD ASD = 6.00 8.00 # 4 # 4 = 32.00 16.00 Center Edge 0.848 0.489 lbs = 104.2 274.8 lbs = ft-# = 439.9 945.5 ft-# _ ti ft-# = 518.6 1,931.1 psi = 5.9 3.0 psi = E psi = 52.5 52.3 in2 = 17.53 91.50 psf = 47.0 84.0 in= 2.81 5.25 psi = 2,000 2,000 psi = 32,000 32,000 = No Yes = 16.11 16.11 In = 3.39 7.63 _ ASD psi = psi - ,RQFESS10N �r�FtQUg �, ��N 2 Ltl ti c� w m 61 A i 0 N0. 83660 n * EXP. 03/31/2025 J+4 C / V `v E OF CA010 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall _ Project File: beazer homes_cantera_la quinta.ec6 LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (04b) 3' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 2.25 Total Footing Width = 2.75 Footing Thickness = 12.00 in Key Width — 0.00 in Key Depth = 0.00 in Key Distance from Toe — 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe Heel Factored Pressure = 2,718 Mu': Upward = 304 Mu': Downward = 52 Mu: Design = 252 OK phiMn = 2,500 2 Actual 1 -Way Shear = 8.40 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Accerrtable Sizes & Soacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 21 ft-# 901 ft-# 881 ft-# OK ,500 ft-# 6.60 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.71 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one laver of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in �RpFESS�oN Oka �rGftPtlG � �, 4� Cts m M DIS N0. 83660 * EXP. 03/31/2025 C i V �w rF op cA`SFo4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2 14 ORCO BLOCK COMPANY INC DESCRIPTION: (04b) 3' ret with top out Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item lbs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 280.0 1.33 373.3 55.1 0.66 36.3 104.2 8.22 856.6 Total = 439.2 O.T.M. = 1,266.2 Resisting/Overturning Ratio = 1.64 Vertical Loads used for Soil Pressure = 1,537.0 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 .....RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 546.3 1.96 1,069.7 Soil Over HL (bel. water tbl) 1.96 1,069.7 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = ` Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.2 Surcharge Over Toe = Stem Weight(s) = 549.5 0.79 433.1 Earth @ Stem Transitions= Footing Weight = 412.5 1.38 567.2 Key Weight = Vert. Component = Total = 1,537.0 lbs R.M.= 2,077.2 ` Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.305 in tlhe above calculation is not valid if the heel soil bearing wessura exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Q%0rESS$DN 01RDUG �yc ND. 83660 n . * EXP. 03I3t(=5 Ile C I V'Y' OF GA6�FQ Cantilevered Retaining Wall L1C+i' KW -06016003, Build'20.23.2.14 DESCRIPTION: (04c) 4' ret with top out Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Project Title: Engineer: Project ID: Project Descr: ORCa BLOCK COMPANY INC Criteria 148.8 #/ft Soil Data 8.72 ft Retained Height = 4.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil - 6.33 ft Equivalent Fluid Pressure Method 0.0 psf (Strength Level) Active Heel Pressure - 35.0 psf/ft Slope Behind Wall = 0.00 Poisson's Ratio = 0.300 Height of Soil over Toe - 6.00 in = Water height over heel - 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 8.72 ft ...Height to Bottom = 7.72 ft Load Type = Seismic (E) Eccentricity = (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Base Above/Below Soil = Project File: beazer homes_cantera-la quinta.ec6 [c] ENERCALC INC 1983.2022 i _ _ - F -- Adjacent Footing Load Adjacent Footing Load = 1,500.0 lbs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil = -1.5 ft at Back of Wall Poisson's Ratio = 0.300 eROFEss/OH a ��4k4v�ERDUC �y 07 w »l m NO 63660 n A * EXP 03/31/2025 s� C I v Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIC0 : KW -46016003. 0thid:20.?3.2.1-: ORCO BLOCK COMPANY INC (C) ENERCALC INC 1983-2022 DESCRIPTION: (04c) 4' ret with top out Design Summary Stem Construction 2nd Bottom Stem OK StemOK Design Height Above Ftg ft = 4.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.66 OK Design Method = ASD ASD Sliding - 1.54 OK Thickness = 6.00 8.00 Global Stability = 2.87 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 16.00 Total Bearing Load = 2,006 lbs Rebar Placed at = Center Edge ...resultant ecc. = 10.91 in Design Data Eccentricity outside middle third fb/FB + fa/Fa = 0.848 0.760 Soil Pressure @ Toe = 2,264 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs = 104.2 439.2 Allowable = 2.667 psf Strength Level lbs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 3,170 psf Service Level ft-#= 439.9 1,468.9 ACI Factored @ Heel = 0 psf Strength Level ft -4 = Footing Shear @ Toe = 10.2 psi OK Moment..... Allowable ft-#= 518.6 1,931.1 Footing Shear @ Heel = 8.5 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 5.9 4.8 Sliding Caics Strength Level psi = Lateral Sliding Force = 650.6 lbs Shear..... Allowable psi = 52.5 52.6 less 100% Passive Force - 196.8 lbs Anet (Masonry) int = 17.53 91.50 less 100% Friction Force - 802.2 lbs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' m= 2.81 5.25 ....for 1.5 Stability = 0.0 lbs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 32,000 Solid Grouting = No Yes Load Factors Modular Ratio 'n' = 16.11 16.11 Building Code Equiv. Solid Thick. in= 3.39 7.63 Dead Load 1.200 Masonry Block Type - Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi .= 4�tpFESS104, ti �� x w 0 m N0. 83469 A �1[ EXP. 43/31/2025 5�4r C/ V ap C A01 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: Beazer homes_cantera_la quinta.ec6 LJC4 : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (C) ENERCALC INC 1983.2022 DESCRIPTION: (04c) 4' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 2.50 Total Footing Width — 3.00 Footing Thickness = 12.00 in Key Width 12.00 in Key Depth = 4.00 in Key Distance from Toe = 0.50 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe Heel Factored Pressure = 3,170 Min footing T&S reinf Area per foot Mu': Upward = 359 If one layer of horizontal bars: Mu': Downward = 52 1, Mu: Design = 307 OK 1, phiMn = 2,500 2 Actual 1 -Way Shear = 10.21 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacinos Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: phiMn = phi*5'lambda*sgrt(fc)*Sm 0 psf 66 ft-# 454 ft-# 388 ft-# OK ,500 ft-# 8.45 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Q�,�xess,oro w � , IW: NO 83660 D * EXP. 03/31/2025 syr C / V 0 E OF CA_"� Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (04c) 4' ret with top out Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item lbs It ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 437.5 1.67 729.2 109.0 1.08 117.9 104.2 9.22 960.8 Total = 650.6 O.T.M. = 1,807.9 Resisting/Overturning Ratio = 1.66 Vertical Loads used for Soil Pressure = 2,005.6 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazar homes__cantera_la quinta- (c) ENERCALC INC 1983-2022 .....RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 843.3 2.08 1,756.9 Soil Over HL (bel. water tbl) 2.08 1,756.9 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.2 Surcharge Over Toe = Stem Weight(s) = 633.5 0.79 503.1 Earth @ Stem Transitions = Footing Weight = 450.0 1.50 675.0 Key Weight = 50.0 1.00 50.0 Vert. Component = Total = 2,005.6 lbs R.M.= 2,992.3 . Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Dell @ Top of Wall (approximate only) 0.361 in The above calculation isnot valid if the _heel _soil bearing pressure exceeds that of the. t_ae because the wall would then tend to rotate into the retained soil. eROFESS+�ro4 �w415 JERt7UG w� of p NO. 83660 n * EXP. 03/31/2025 1P�4 P C / V F OF CA%-% 4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: bearer homes,, cantera., la quinta.ec6 LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (04d) 5' ret with top out Code Reference, Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data Retained Height = 5.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil - 6.33 ft Equivalent Fluid Pressure Method * EXP 03/31/2025 qr C / V � \- F OF CA? �F Active Heel Pressure - 35.0 psf/ft Slope Behind Wall - 0.00 Height of Soil over Toe = 6.00 in = Water height over heel - 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load Surcharge Over Heel - 0.0 psf Lateral Load = 148.8 #/ft Adjacent Footing Load = 1,500.0 lbs Used To Resist Sliding & Overturning ...Height to Top = 9.72 ft Footing Width = 1.50 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 8.72 ft Eccentricity = 0.00 in Used for Sliding & Overturning Load Type = Seismic (E) Wall to Ftg CL Dist = 5.00 ft Axial Load Applied to Stem (Strength Level) Footing Type Spread Footing Base Above/Below Soil 1.5 ft Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall - Axial Live Load = 0.0 lbs (Strength Level) Poisson's Ratio - 0.300 Axial Load Eccentricity = 0.0 in QROFES S/pH rnm m �a �4 N0. 83660 * EXP 03/31/2025 qr C / V � \- F OF CA? �F o Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIC# - KW06016003. 1301d:20.23.2.14 ORCO BLOCK COMPANY INC (c)ENERCALC INC 1983.2022 DESCRIPTION: (04d) 5' ret with top out Design Summary Stem Construction 2nd Bottom - - Stem OK StemOK Design Height Above Ftg ft = 5.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.83 OK Design Method = ASD ASD Sliding = 1.52 OK Thickness = 6.00 8.00 Global Stability 2.68 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 8.00 Total Bearing Load = 2,700 lbs Rebar Placed at = Center Edge ...resultant ecc. = 11.50 in Design Data -- - -- - - - - Eccentricity outside middle third fb/FB + fa/Fa 0.848 0.891 Soil Pressure @ Toe = 2,274 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs = 104.2 650.6 Allowable = 2,667 psf Strength Level lbs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 3,183 psf Service Level ft-#= 439.9 2,334.7 ACI Factored @ Heel = 0 psf Strength Level ft-# = Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable ft-# = 518.6 2,617.5 Footing Shear @ Heel = 8.8 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 7.1 Sliding Calcs Strength Level psi = Lateral Sliding Force = 896.4 lbs Shear..... Allowable psi = 52.5 53.0 less 100% Passive Force - 278.4 lbs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force s - 1,080.2 lbs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 2.81 5.25 ....for 1.5 Stability = 0.0 lbs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi= 32,000 32,000 Solid Grouting = No Yes Load Factors Modular Ratio 'n' - 16.11 16.11 Building Code Equiv. Solid Thick. in= 3.39 7.63 Dead Load 1.200 Masonry Block Type - Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data - Wind, W 1.000 Pc psi= Seismic, E 1.000 Fy psi= QROFESSIaN hk'¢ru4�arGFtD[1 c� TS4' m w at N0. 53650 * ERP 03/31/2025 �rq r V Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIGN : RW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (04d) 5' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 3.00 Total Footing Width = 3.50 Footing Thickness = 12.00 in Key Width = 12.00 in Key Depth = 7.00 in Key Distance from Toe = 0.50 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As %0.0018 �@ Cover @ Top 2.00 Btm: 3.00 in Footing Design Results Toe Heel Factored Pressure = 3,183 Min footing T&S reinf Area per foot Mu': Upward = 370 If one Iaye r of horizontal bars: T Mu': Downward = 52 2 Mu: Design = 318 OK 2 phiMn = 2,500 2 Actual 1 -Way Shear = 10.73 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Accentable Sizes & SDacincs Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: phiMn = phi*5'lambda*sgrt(fc)*Sm 0 psf 394 ft-# 707 ft-# 312 ft-# OK ,500 ft-# 8.76 psi 0,00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.91 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one Iaye r of horizontal bars: T It two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Z`yOFEss/oryA 4io dERDOG m m �. 01r" N0. 83660 * EXP 03/31/2025 tr ��qr C 1 V 1 \.- q� Cantilevered Retaining Wall LIC# - KW -06016003, Build -M-212.14 DESCRIPTION: (04d) 5' ret with top out Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item lbs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 630.0 2.00 1,260.0 162.3 1.57 254.1 104.2 10.22 1,064.9 Total 896.4 O.T.M. = 2,579.1 Resisting/Overturning Ratio = 1.83 Vertical Loads used for Soil Pressure = 2,700.4 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC NO 18#34622 .....RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 1,341.7 2.33 3.130.E Soil Over HL (bel. water tbl) 2.33 3,130.E Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.e Surcharge Over Toe = Stem Weight(s) = 717.5 0.80 573.1 Earth @ Stem Transitions= Footing Weight = 525.0 1.75 918.8 Key Weight = 87.5 1.00 87.5 Vert. Component = Total = 2,700.4 lbs R.M.= 4,717.1 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl Q Top of Wall (approximate only) 0.341 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the tae, because the wall would then tend to rotate into the retained soil. QROFESS/4H W aim No. 83660 * EXP. 03/31/2025 sT�r C / V } L �tia E OF CAL��O ORCO 6' HIGH WALL W/ RETAINING & HEELBACK FOOTING FOR 110 MPH WIND 3 SEC. GUST @a EXP C SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRY STEM. CAP UNIT DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH, f', = 2000 PSI. LEVEL BACKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D 'B' 'C'&'D' BARS GENERAL NOTES: 2'-9" I 1 @24"O/L' r ORCO 6616 CMU 1 C' DOWEL L 4'-0" 3'-3" GROUTED ONLY @ VERT STEEL U W 3'-6" #4@8" 0/C 1. CONCRETE BLOCKSHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 4"DLA SDR 35 PERF PIPE ti b� #4 VERT DROP-IN BAR @ 32" OIC 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS 2 U' O 2" CLR GRAVEL WRAPPED W1 @ CENTER OF CMU. PROVIDE 24" MIN LAP INTO 8" CMU SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS MIRAR 14ON FILTER W E OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM FABRIC TO WITMN 1 FT OF H C 150 TYPE II/V. Fc = 2500 PSI o • WATERPROOF BACKSIDE #6 STD JOINT 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A OF RETAINING WALL. REINFORCEMENT @ 12' O/C 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. {�\f 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH 2 CCR. IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. LEVEL BACKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D �• • A'4 HORZ. CONT. 1"C1R @12"OIC 3"CLR. 3•CLR. 'A 'B' 'C'&'D' BARS N4 HORZ CONT. 2'-9" I 1 @24"O/L' 3'-0" 1 C' DOWEL L 4'-0" 3'-3" @ EDGE OF 8" CMU 12" U W 3'-6" #4@8" 0/C 4"DLA SDR 35 PERF PIPE ti b� W/1FTWIDE0F}" 2 U' O 2" CLR GRAVEL WRAPPED W1 yR O p MIRAR 14ON FILTER W E FABRIC TO WITMN 1 FT OF H FG - SLOPE TO DRAIN. • WATERPROOF BACKSIDE OF RETAINING WALL. {�\f n 2 CCR. ry �• • A'4 HORZ. CONT. 1"C1R @12"OIC 3"CLR. 3•CLR. 'A 'B' 'C'&'D' BARS 2'-0" 2'-9" #4@32" 0/C 3'-0" 3'-0" #4@l6" 0/C 4'-0" 3'-3" #4@l6" 0/C 5'-0" 3'-6" #4@8" 0/C 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VER7IC4L IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. DETAIL #5 ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. BEAZER HOM CANTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SC4LE. I4�ID yER❑OG ( � W � yl�9�zoZ3; NO. 83660 * EXP. 03/31/2025 SqT C IV %\- 09'� F 0F CA0F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : M-06016663. BuJM 20 23.2.14 ❑RCO BLOCK COMPANY ING DESCRIPTION: (05a) 2' ret with top out -heel footing Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria = 148.8 #/ft Soil Data = 6.72 ft Retained Height = 2.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.33 ft Equivalent Fluid Pressure Method _ -1.5 ft at Back of Wall Active Heel Pressure - 35.0 psf/ft Slope Behind Wall - 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 In Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 6.72 ft ...Height to Bottom = 5.72 ft Load Type = Seismic (E) Footing Type (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazer homes_cantera_la quinta.ec6 (c) ENIFFICALC INC 1983.2022 i i :I Ik I it i I Adjacent Footing Load Adjacent Footing Load = 1,500.0 lbs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil _ -1.5 ft at Back of Wall Poisson's Ratio = 0.300 QapF ESS/Ok ��a yERdtJ F Ix nIrnA nra. asaao * EXP, 0313112025 s qr C, � � 1 V ����► .. F OP CALIFO Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beater homes_cantera_la quinta.ec6 LIC# : KW -06016003, Bulld:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENEFICALC INC 1983-2022 DESCRIPTION: (05a) 2' ret with top out -heel footing Design Summary Stem Construction 2nd Bottom Stem OK StemOK Design Height Above Ftg ft= 2.00 0.00 Wall Stability Ratios Wall Material Above "Ht" - Masonry Masonry Overturning = 1.66 OK Design Method = ASD ASD Sliding - 2.46 OK Thickness = 6.00 8.00 Global Stability = 4.76 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 32.00 Total Bearing Load = 1,357 lbs Rebar Placed at = Center Edge ...resultant ecc. = 11.17 in Design Data Eccentricity outside middle third fb/FB + fa/Fa 0.848 0.703 Soil Pressure @ Toe = 2,038 psf OK Total Force @ Section Soil Pressure Q Heel = 0 psf OK Service Level lbs = 104.2 174.2 Allowable = 2,667 psf Strength Level lbs= Soil Pressure Less Than Allowable Moment.... Actual ACI Factored Q Toe = 2,854 psf Service Level ft-# = 439.9 694.9 ACI Factored @ Heel = 0 psf Strength Level ft-#= Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable ft-# = 518.6 987.8 Footing Shear Q Heel = 4.0 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 1.9 Sliding Calcs Strength Level psi = Lateral Sliding Force = 274.8 lbs Shear..... Allowable psi = 52.5 52.0 less 100% Passive Force 104.2 lbs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force =_ - 571.9 lbs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 2.81 5.25 ....for 1.5 Stability = 0.0 lbs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi= 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi= 32,000 32,000 Solid Grouting = No Yes Load Factors Modular Ration' - 16.11 16.11 Building Code Equiv. Solid Thick. in � 3.39 7.63 Dead Load 1.200 Masonry Block Type - Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = QRpFESS10 4eRDU " Q• -a s , NO- $3660 A' * EXP. 0313118025 s�qr C I Y � N- o4�` O F L h, 1 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05a) 2' ret with top out—heel footing Footing Data Toe Width = 0.00 ft Heel Width = 2.75 Total Footing Width = 2.75 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983.2022 Toe Heel Factored Pressure = 2,854 0 psf Mu': Upward = 0 105 ft-# Mu': Downward = 0 1,148 ft-# Mu: Design = 0 OK 1,043 ft-# OK phiMn = OK - Flush 2,500 Actual 1 -Way Shear = 10.73 3.97 psi Allow 1 -Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft -lbs Footing Allow. Torsion, phi Tu = 0.00 ft -lbs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Soacinns Toe: Flush toe condition. No reinforcing required Heel: phiMn = ph'5`lambda'sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area 0.71 int Min footing T&S reinf Area per foot 0.26 int eft It one laver of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Q"of ESS 10H 4 F� � w 47 ■■■ Q rn N0. 63660 * EXF 03/51/2025 sq CIV �� OF CA0104 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -0601600. Build. M23.2.14 ORCO BLOCk COMPANY INC DESCRIPTION: (05a) 2' ret with top out—heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 157.5 1.00 13.2 0.29 104.2 7.22 Total 274.8 O.T.M. = Resisting/OverturnIng Ratio = 1.66 Vertical Loads used for Soil Pressure = 1,357.2 lbs Project File: beazer homes_cantera_la quinta.ec6 (o} ENERCALC INC 19832022 ...RESISTING..... Force Distance Moment lbs It ft-# 157.5 Soil Over HL (ab. water tbl) 479.2 1.71 818.E Soil Over HL (bel. water tbl) 1.71 818.E Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = 3.8 Axial Dead Load on Stem = 752.4 " Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 465.5 0.28 130.4 Earth @ Stem Transitions = 913.7 Footing Weight = 412.5 1.38 567.2 Key Weight = Vert. Component = Total = 1,357.2 lbs R.M.= 1,516.1 " Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.286 in The above calculation is not valid it tho hael sail boa drK r.ressure exceeds thal of the toe. because the wall would then tend to rotate into the retained soil. 4,OF ESS10N w � m a N0. 83660 D * EXP 03/31/2025 s�qr t= / V E ofo CA4�f Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05b) 3' ret with top out -heel footing Code Reference. Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria = 1,500.0 lbs Soil Data = 1.50 ft Retained Height = 3.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.33 ft Equivalent Fluid Pressure Method at Back of Wall Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load ...Height to Top ...Height to Bottom Load Type 148.8 #/ft = 7.72 ft 6.72 ft Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File; beater homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 Adjacent Footing Load Adjacent Footing Load = 1,500.0 lbs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = -1.5 ft Poisson's Ratio = 0.300 QaOFESS /n,V Q- rt M w �I m Cr Q NO 63660 n A * EXP 03/31/2025 STq r j V F 4F EAL.�f Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY ING DESCRIPTION: (05b) 3' ret with top out -heel footing Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 Design Summary Stem Construction _ 2nd Bottom_ - Stem OK Stem OK Design Height Above Ftg ft = 3.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.82 OK Design Method - ASD ASD Sliding = 2.00 OK Thickness - 6.00 8.00 Global Stability = 3.82 Rebar Size # 4 # 4 Rebar Spacing - 32.00 16.00 Total Bearing Load = 1,805 lbs Rebar Placed at = Center Edge ...resultant ecc. = 11.06 in Design Data Eccentricity outside middle third fb/FB + fa/Fa 0.848 0.489 Soil Pressure @ Toe = 2,081 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs = 104.2 274.8 Allowable = 2,667 psf Strength Level lbs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 2,914 psf Service Level ft-# = 439.9 945.5 ACI Factored @ Heel = 0 psf Strength Level ft-# _ Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable ft-#= 518.6 1,931.1 Footing Shear @ Heel = 3.6 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 3.0 Sliding Calcs Strength Level psi = Lateral Sliding Force = 439.2 lbs Shear..... Allowable psi = 52.5 52.3 less 100% Passive Force - 104.2 lbs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force =_ - 773.5 lbs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 2.81 5.25 ....for 1.5 Stability = 0.0 lbs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm PSI = 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 32,000 Solid Grouting = No Yes Load Factors Modular Ratio 'n' = 16.11 16.11 Building Code Equiv. Solid Thick. in= 3.39 7.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psl = Seismic, E 1.000 Fy psi = QROFESS��k� 4�o yEnDUc N0. 83660 * EXP. 03131/ZC25 tlr s sr C f V F op C4,01 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23 2 14 ORCO BLOCK COMPANY INC DESCRIPTION: (05b) 3' ret with top out -heel footing Footing Data Toe Width = 0.00 ft Heel Width = 3.00 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth - 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File; Beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983.2022 Toe Heel Factored Pressure = 2,914 0 psf Mu': Upward = 0 341 ft-# Mu': Downward = 0 1,848 ft-# Mu: Design = 0 OK 1,507 ft-# OK phiMn = OK - Flush 2,500 Actual 1 -Way Shear = 10.73 3.57 psi Allow 1 -Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft -lbs Footing Allow. Torsion, phi Tu = 0.00 ft -lbs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: Flush toe condition. No reinforcing required. Heel: phiMn = ph'5'lambda'sgrt(fc)"Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one laver of horizontat bars: #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in 0.78 int 0.26 int /ft If two lavers of {horizontal gars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in �RpPESS 10 yEFtDUO N0. 83660 D EXP. 03/31/2025 s9r C f V R OF C401 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05b) 3' ret with top out_heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING.... Force Distance Moment Item lbs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 280.0 1.33 373.3 55.1 0.66 36.3 104.2 8.22 856.6 Total = 439.2 O.T.M. = 1,266.2 Resisting/Overturning Ratio = 1.82 Vertical Loads used for Soil Pressure = 1,804.5 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: bearer homes_cantera_la quinta.ecG 1 (c) ENERCALC INC 1983-2022 1 .....RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 805.0 1.83 1,475.8 Soil Over HL (bel. water tbl) 1.83 1,475.8 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 549.5 0.29 158.4 Earth @ Stem Transitions = Footing Weight = 450.0 1.50 675.0 Key Weight = Vert. Component = Total = 1,804.5 lbs R.M.= 2,309.2 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.300 in The above calcufalion is not vatid if the heel soi[ bearing press_ure_excoods that of the toe, because the wall would then tend to rotate into the retained soil. eRpfESS IQM i�4r`4 �jSRDUG Fc 0m N0. 83660 * EXP 03/31/2025 sqr CfV1L ¢�d F OF CA'0* Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall I.IC4 - RW -06016003. Buiid:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05c) 4' ret with top out -heel footing Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 4.00 ft Wall height above soil = 6.33 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel — 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Project File: beazer homes_cantera—la quinta.ec6 ` (c) ENERCALC INC 1983-2022 J Soil Data j Allow Soil Bearing = 2,666.6 psf + Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingllSoil Friction = 0.400 Soil height to ignore (Strength Level) for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 8.72 ft ...Height to Bottom = 7.72 ft Load Type = Seismic (E) Footing Type (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) _ 1.5 ft — I 1 i Adjacent Footing Load Adjacent Footing Load = 1,500.0 lbs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall _ 1.5 ft — Poisson's Ratio = 0.300 QROFESS�O� ti� rL�' �Y►� c m'm eva. 83560 0iM Yr EXP. 05/31/2025 4�r C IV }V. �$tP E OF CAL�40 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIC# : KW -06016003, Build: 20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983.2022 DESCRIPTION: (05c) 4' ret with top out -heel footing Design Summary Wall Stability Ratios Overturning = 1.83 OK Sliding = 1.70 OK Global Stability - 3.25 Total Bearing Load = 2,309 lbs ...resultant ecc. = 11.72 in Eccentricity outside middle third Soil Pressure ® Toe = 2,374 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 3,323 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 10.7 psi OK Footing Shear @ Heel = 4.1 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 650.6 lbs less 100% Passive Force 104.2 lbs less 100% Friction Force = - 1,004.5 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 Stability = 0.0 lbs OK Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' 2nd Stem OK ft = 4.00 = Masonry ASD 6.00 _ # 4 = 32.00 Center 0.646 Bottom StemOK 0.00 Masonry ASD 8.00 # 4 16.00 Edge 0.760 lbs = Masonry Data Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs ft-# = Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data Wind, W 1.000 f'c Seismic, E 1.000 Fy 2nd Stem OK ft = 4.00 = Masonry ASD 6.00 _ # 4 = 32.00 Center 0.646 Bottom StemOK 0.00 Masonry ASD 8.00 # 4 16.00 Edge 0.760 lbs = 104.2 439.2 lbs = ft-# = 439.9 1,468.9 ft-# = ft-# = 518.6 1,931.1 psi = 5.9 4.8 psi = psi = 52.5 52.6 int = 17.53 91.50 psf = 47.0 84.0 in= 2.81 5.25 psi = 2,000 2,000 psi = 32,000 32,000 = No Yes = 16.11 16.11 in= 3.39 7.63 psi = psi = ASID QRoFEss,QN Iwo .teRDUG F NO. $3600 � * EXP. 6S1'�1120P5 S � 9p C IV pt's 0, CAL�f0 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, 6L1Ifd:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05c) 4' ret with top out—heel footing Footing Data Toe Width = 0.00 ft Heel Width = 3.25 Total Footing Width = 3.25 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC; 1983-2022 Toe Heel Factored Pressure = 3,323 0 psf Mu': Upward = 0 596 ft-# Mu': Downward = 0 2,758 ft-# Mu: Design = 0 OK 2,162 ft-# OK phiMn = OK - Flush 2,500 Actual 1 -Way Shear = 10.73 4.12 psi Allow 1 -Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft -lbs Footing Allow. Torsion, phi Tu = 0.00 ft -lbs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & SDacinas Toe: Flush toe condition. No reinforcing required Heel: phiMn = ph'5'lambda'sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area 0.84 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one laVer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in eRprtessroro T" rrk Ia, PIM N0. 83660 * EXP. 63/31/2625 * . J+T�l C / V CF CA01 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIN : KW -06016603. 9ulld:P6.0.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05c) 4' ret with top out—heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item lbs ft ft-# HL Act Pres (ab water tbl) 437.5 1.67 729.2 HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = 109.0 1.08 117.9 Added Lateral Load = 104.2 9.22 960.8 Load @ Stem Above Soil = Total _ 650.6 O.T.M. = 1,807.9 Resisting/OverturnIng Ratio = 1.83 Vertical Loads used for Soil Pressure = 2,309.3 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes _cantera_la quinta.ec6 to tNERCALC INC 1983-2022 Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth @ Stem Transitions= Footing Weight = Key Weight = Vert. Component = .....RESISTING..... Force Distance lbs ft 1,188.3 1.96 1.96 633.5 0.29 487.5 1.63 Moment ft-# 2,327.2 2,327.2 186.4 792.2 Total = 2,309.3 lbs R.M.= 3,305.7 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.349 in The above calculation is not valid if the heel soil bearinu pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. QRpp E 55 1 o,4,4 n � Q7 rf1' m N0. 83660 * EXP. 03/31/2025 syr C/V1�- ¢a'4 R OF Ckof Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05d) 5' ret with top out -heel footing Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Project File: beater homes_canteraJa quinta.ec6 (c) ENERCALC INC 1983-2022 Criteria 148.8 #/ft Soil Data 9.72 It ...Height to Bottom = Retained Height = 5.00 ft Allow Soil Bearing = 2,666.6 psf (Strength Level) Wall height above soil = 6.33 ft Equivalent Fluid Pressure Method I Poisson's Ratio = 0.300 Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 � Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft ; • yrT Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel — 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 9.72 It ...Height to Bottom = 8.72 ft Load Type = Seismic (E) Footing Type (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) 1.5 ft Adjacent Footing Load Adjacent Footing Load = 1,500.0 lbs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 It Footing Type Spread Footing Base Above/Below Soil at Back of Wall 1.5 ft Poisson's Ratio = 0.300 QROFESS 1�3 aeRDIJ co rt5 m w O m N0. 63660 D y1• EXP 03/31/2025 sT C f V 4rfi 0, CAV. *�¢ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beater homes_cantera-la quinta.ec6 LTCN : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1963-2022 DESCRIPTION: (05d) 5' ret with top out -heel footing Design Summary Stem Construction _ _2nd Bottom - - Stem OK Stem OK Design Height Above Ftg ft= 5.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.94 OK Design Method ASD ASD Sliding = 1.59 OK Thickness - 6.00 8.00 Global Stability = 2.86 Rebar Size - # 4 # 4 Rebar Spacing = 32.00 8.00 Total Bearing Load = 3,017 lbs Rebar Placed at = Center Edge ...resultant ecc. = 11.37 in Design Data Eccentricity outside middle third fb/FB + fa/Fa 0.848 0.891 Soil Pressure @ Toe = 2,507 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs= 104.2 650.6 Allowable = 2.667 psf Strength Level lbs= Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 3,510 psf Service Level ft-# = 439.9 2,334.7 ACI Factored @ Heel = 0 psf Strength Level ft-# = Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable ft-# = 518.6 2,617.5 Footing Shear @ Heel = 2.1 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 7.1 Sliding Calcs Strength Level psi = Lateral Sliding Force = 896.4 lbs Shear..... Allowable psi = 52.5 53.0 less 100% Passive Force - 104.2 lbs Anet (Masonry) int = 17.53 91.50 less 100% Friction Force 1,323.0 lbs Wall Weight psf= 47.0 84.0 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 2.81 5.25 ....for 1.5 Stability = 0.0 lbs OK Masonry Data - Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 32,000 Solid Grouting - No Yes Load Factors Modular Ratio 'n' = 16.11 16.11 Building Code Equiv. Solid Thick. in= 3.39 7.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 Pc psi = Seismic, E 1.000 Fy psi = eROFESS/ON 4 IV it W' vlA, i N0. 83660 D * EXP. 03/31/2025 C I V g 0" CA6�P0 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# . KW-oaaim 43. 13010:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05d) 5' ret with top out—heel footing Footing Data Toe Width 0.00 ft Heel Width 3.50 Total Footing Width 3.50 Footing Thickness 12.00 in Key Width 0.00 in Key Depth 0.00 in Key Distance from Toe 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density 150.00 pcf Min. As % 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 {c} ENERCALC INC 1983.2022 Toe Heel Factored Pressure 3.510 0 psf Mu': Upward 0 1.280 ft-# Mu': Downward 0 3.903 ft-# Mu: Design 0 OK 2,623 ft-# NG phiMn = OK - Flush 2,500 Actual 1 -Way Shear = 10.73 2.15 psi Allow 1 -Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu 0.00 ft -lbs Footing Allow. Torsion, phi Tu = 0.00 ft -lbs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: Flush toe condition. No reinforcing required. Heel: phiMn = ph'5`lambda`sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area 0.91 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in QROFESS /6 af FDLI 01 �c rtA m m NO 83660 * EXP 05/31/2025 V 1 9r� Op CA`\�0¢ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beater homes_cantera_la quinta.ec6 LIC# : KW -06016003. Budd:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983.2022 DESCRIPTION: (05d) 5' ret with top out—heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance oment M Force Distance Moment Item lbs It ft-# lbs ft ft-# HL Act Pres (ab water tbl) 630.0 2.00 1,260.0 Soil Over HL (ab. water tbl) 1,629.2 2.08 3,394.1 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.08 3,394.1 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = 145.2 3.25 471.8 Adjacent Footing Load = 162.3 1.57 254.1 Axial Dead Load on Stem = Added Lateral Load = 104.2 10.22 1,064.9 ' Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = = Surcharge Over Toe = Stem Weight(s) = 717.5 0.30 214.4 Earth @ Stem Transitions= Total 896.4 O.T.M. = 2,579.1 Footing Weight = 525.0 1.75 918.8 Key Weight = Resisting/Overturning Ratio = 1.94 Vert. Component = Vertical Loads used for Soil Pressure = 3,016.8 lbs Total = 3,016.8 lbs R.M.= 4,999.0 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.376 in The above calculation is not _valid _if the heel soil bearing pressure exceeds that of the tae. because the wall would then tend to rotate into the retained soil. QaOFESS10 -4E1 U o y fic .W olmi N0. 83660 D A yt EXP 03/31/2025 �T4re C 1 V Op CA41f ORCO 12" SQ. PILASTER W/RETAINING DESIGN CRITERIA PER THE 1011 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI Cal 28 DAYS. 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH, f',, = 2000 PSI. SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 AND 4 OF THE MASONRY STEM. ORCO 126/2 PILASTER CMU (SOLID GROUTED) 3-1/2" CLR. (2) #4 VERT. _ DROP -1N BARS #4 DOWELS W1 24'MIN Z EXTENSION INTO CMU z J Q u 12„ QcQ N M �C 7' TO DAYLIGHT �� #4HORZ. — 0 9" 0/C EACH WAY FOR 1/0 MPH EXPOSURE C WIND GENERAL NOTES: 1, CONCRETE BLOCKSHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. CAP UNIT 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOC4TED. 2'-0" 3'-0" 4'-0" 5. CONCRETE BLOCK SHALL BE LAID IN A STACK BOND PATTERN. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. N/A 3'-0" 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART 3'-3" CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 5'-0" B. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART 5" CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK BEAZER HOMES UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT CANTERA @ CORAL MOUNTAIN FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW TRACT No. 31249 LA QUINTA, CALIFORNIA WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAYBE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF CA0F OF THE TRENCH TYPE FOOTING. LEVEL BACKFILL 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL COMPACTED TO OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. MIN. 90"/o RELA77VE COMPACTION PER 11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHES ARE READY FOR ASTM 1557-D CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPEC77ON TO BE WHEN THE REQUIRED VERTIG4L IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHERE MTERSEC77ON BLOCK WALLS OCCUR. EIR 'B' SQUARE FOOT/NG N07E' ONLY RUN WALL FOOTING HORIZONTAL REINFORCEMENT THROUGH PILASTER FOOT/NG, WHEN INTERSECTING ORCO 12612 PILASTER CMU (SOLID 4" DIA. SDR 35 PERF PIPE W/ IFT WIDE OF 4 1 GRAVEL WRAPPED W1 MIRAF1140N FILTER FABRIC TO WIRaN 1FT OF FG - SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL. 12' N 4TICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO S01LE ENGINEERING STAMP APPROVAL IS CONDITIONAL; 2'-0" 3'-0" 4'-0" 3'-0" N/A 3'-0" N/A 3'-3" N/A 5'-0" 3'-6" 5" 12' N 4TICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO S01LE ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. A DETAIL #6 BEAZER HOMES a '/ 02 m CANTERA @ CORAL MOUNTAIN NO. 83660 D TRACT No. 31249 LA QUINTA, CALIFORNIA * EXP. 0313112025 sT4TF I.ALOTE: DIMENSIONS ARE NOT TO SC11LE. OF CA0F Cantilevered Retaining Wall 1.ICu : KW -06016003, Build:20.23.2.14 DESCRIPTION: (06a) Pilaster w/2' ret Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 2.00 ft Wall height above soil = 6.67 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Project Title: Engineer: Project ID: Project Descr: ORtO BLOCK COMPATi} WC Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIiSoil Friction - 0.400 Soil height to ignore (Strength Level) for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 147.8 #/ft ...Height to Top = 6.94 ft ...Height to Bottom = 5.94 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Load Project File' beater homes-cantera_la quinla.ec6 (c) ENERCALC INC 1983-2022 ■ I II ' 1 J Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.300 QaOFEsSIO ,ya 4�0 �r�szauc �, q z . olA NO. 83660 D 7k EXP. 03/31/2025 * . CIV, 4��P F OF CA% -%q Cantilevered Retaining Wall I ICN : KW -06016003, Build:20 23 2.14 DESCRIPTION: (06a) Pilaster w/2' ret Design Summary Wall Stability Ratios Overturning = 1.99 OK Sliding 2.11 OK Global Stability - 3.00 Total Bearing Load = 1,118 lbs ...resultant ecc. r 8.10 in Eccentricity outside middle third Soil Pressure @ Toe = 903 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,265 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 6.1 psi OK Footing Shear @ Heel = 3.3 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 260.9 lbs less 100% Passive Force - 104.2 lbs less 100% Friction Force = - 447.2 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 Stability = 0.0 lbs OK Project Title: Engineer: Project ID: Project Descr: Project File: beater homes_canteraja qulnta.ec6 ORCO BLOCK COMPANY INC (C) ENFACALC INC 1983.2022 Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Bottom Stem OK ft = 0.00 = Masonry ASD ASD -- 12.00 # 4 16.00 Edge 0.211 lbs= 173.4 lbs = ft-#= 712.9 ft-# = 3,371.6 psi = 1.2 psi = psf= 51.1 in2 = 139.50 psf = 43.9 in= 9.00 psi = 2,000 psi = 32,000 Yes 16.11 in= 11.63 psi w psi = ASD eRaFESS�p� �a'�W4��EpiDIJ � Fc 0 NO 83660 D • A * EXP 03/31/2025 0 T4rE C f V ❑p Caw�F Masonry Data Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data Wind, W 1.000 f'c Seismic, E 1.000 Fy Bottom Stem OK ft = 0.00 = Masonry ASD ASD -- 12.00 # 4 16.00 Edge 0.211 lbs= 173.4 lbs = ft-#= 712.9 ft-# = 3,371.6 psi = 1.2 psi = psf= 51.1 in2 = 139.50 psf = 43.9 in= 9.00 psi = 2,000 psi = 32,000 Yes 16.11 in= 11.63 psi w psi = ASD eRaFESS�p� �a'�W4��EpiDIJ � Fc 0 NO 83660 D • A * EXP 03/31/2025 0 T4rE C f V ❑p Caw�F Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (06a) Pilaster w/2' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.00 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Footing Design Results Project File: beezer homes_canteraJa qulnta.ec6 (c) ENERCALC INC 1983-2022 Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one laver of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in 0 psf 9 ft-# 342 ft-# 333 ft-# OK ,500 ft-# 3.32 psi 0.00 psi 00 ft -lbs 00 ft -lbs 0.78 int 0.26 in2 /ft If two lavers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in V%OFESS/O4, ���w9�yERDl1 Fc Q•� Z yst m W w ❑I m A NO 83660 A * EXP 03/31/2025 sqf C 1 v OF cw')*9 Toe Heel Factored Pressure = 1,265 Mu': Upward = 547 Mu': Downward = 187 Mu: Design = 360 OK phiMn = 2,500 2 Actual 1 -Way Shear = 6.14 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Accentable Sizes & SDacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one laver of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in 0 psf 9 ft-# 342 ft-# 333 ft-# OK ,500 ft-# 3.32 psi 0.00 psi 00 ft -lbs 00 ft -lbs 0.78 int 0.26 in2 /ft If two lavers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in V%OFESS/O4, ���w9�yERDl1 Fc Q•� Z yst m W w ❑I m A NO 83660 A * EXP 03/31/2025 sqf C 1 v OF cw')*9 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 KW -t i-som. Wid:M23.2.14 ORCO BLOCK COMPANY INC (c) E-WERCALC lNC 1983.2022 DESCRIPTION: (06a) Pilaster w/2' ret Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# HL Act Pres (ab water tbl) 157.5 1.00 157.5 Soil Over HL (ab. water tbl) 230.0 2.50 575.0 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.50 575.0 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = 103.4 7.44 769.6 Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 57.5 0.50 28.8 Surcharge Over Toe = Stem Weight(s) = 380.5 1.50 570.8 Earth Q Stem Transitions= Total _ 260.9 O.T.M. = 927.1 Footing Weight = 450.0 1.50 675.0 Key Weight = Resisting/Overturning Ratio = 1.99 Vert. Component = Vertical Loads used for Soil Pressure = 1,118.0 lbs Total = 1,118.0 lbs R.M.= 1,849.5 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.121 in The above calculation is not valid ff the heel soil bearing pressure exceeds that of thea tao. because the wall would then tend to rotate into the retained soil. QRpfess+oH IeRDU NO 83660 D * EXP 03/31/2025 ' (+T4r C r V OF C A0* Cantilevered Retaining Wall LIC# : KW -06016003. Build: 20.23.2.14 DESCRIPTION: (06b) Pilaster w/3' ret Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INN Criteria 147.8 #/ft Soil Data 7.94 ft Retained Height = 3.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.67 ft Equivalent Fluid Pressure Method 0.0 psf (Strength Level) Active Heel Pressure - 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingllSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load - 147.8 #/ft ...Height to Top - 7.94 ft ...Height to Bottom = 6.94 ft Load Type = Seismic (E) Footing Type (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) - 0.0 ft Project File: beater homescanteraja quinta.ec6 (c) ENERCALC INC 1983.2022 Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall - 0.0 ft Poisson's Ratio = 0.300 QRoFESS4 0 CZ) rn m NO 83660 * EXP 03/31/2025 Sq CIV 1V T10' TF OF CAl\F Cantilevered Retaining Wall LICO : KW06016003. Build:20.23.2.141 DESCRIPTION: (06b) Pilaster w/3' ret Project Title: Engineer: Project ID: Project Descr: Project File: beazer homes_cantera_la quinta.ec6 0 CO BLOCK COMPANY INC Gc] ENERCALC INC 1983.2022 Design SU[nmary Stem Construction Bottom_ Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Overturning = 1.77 OK Design Method ASD Sliding 1.60 OK Thickness = 12.00 Global Stability = 2.60 Rebar Size = # 4 Rebar Spacing = 16.00 Total Bearing Load = 1,277 lbs Rebar Placed at = Edge ...resultant ecc. = 9.01 in Design Data Eccentricity outside middle third fb/FB + fa/Fa = 0.274 Soil Pressure @ Toe = 1,136 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs = 260.9 Allowable = 2,667 psf Strength Level lbs= Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 1,591 psf Service Level ft-#= 927.1 ACI Factored @ Heel = 0 psf Strength Level ft-# = Footing Shear @ Toe = 8.0 psi OK Moment..... Allowable = 3,371.6 Footing Shear @ Heel = 4.8 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 1.9 Sliding Calcs Strength Level psi = Lateral Sliding Force = 383.4 lbs Shear..... Allowable psi = 51.2 less 100% Passive Force 104.2 lbs Anet (Masonry) in2 = 139.50 less 100% Friction Force 510.8 lbs Wall Weight psf = 43.9 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in = 9.00 ....for 1.5 Stability = 0.0 lbs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting _ Yes Load Factors Modular Ratio 'n' = 16.11 Building Code Equiv. Solid Thick. in = 11.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data _ Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = ASD QaoFESS h�¢g9 ��riDtJ� j fi� �v w O m ice. DIA, NO 83660 yt EXP 03/31/2025 11 q C f V � v ¢�'� F OF GA010' Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: Beazer homes cantera_fa quinta.ec6 I LICK : KW -06016003, I3uild:26.23.2.id C]RGfl BLOCK COMPANY INC (c) ENERCAL.0 INC 1983-2622 I DESCRIPTION: (06b) Pilaster w/3' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.00 Total Footing Width - 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe: phiMn = ph*5*lambda'sgrt(fc)`Sm Heel: phiMn = ph*5*lambda`sgrt(fc)'Sm Key: No key defined I 0 psf 2 ft-# 446 ft -4 444 ft-# OK ,500 ft-# 4.77 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area Toe Hee Factored Pressure = 1,591 Mu': Upward = 678 Mu': Downward = 187 Mu: Design = 491 OK phiMn = 2,500 2 Actual 1 -Way Shear = 8.04 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceotable Sizes & SQacinas Toe: phiMn = ph*5*lambda'sgrt(fc)`Sm Heel: phiMn = ph*5*lambda`sgrt(fc)'Sm Key: No key defined I 0 psf 2 ft-# 446 ft -4 444 ft-# OK ,500 ft-# 4.77 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one laver of horizontal bars: It two is ers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in eRpFESS/oN rn m W aI A NO 03660 D * EXP 05/31/2025 S 7 F OF CA F9 Cantilevered Retaining Wall I IC,f : KW -06016003, Build: 20.23.2.14 DESCRIPTION: (06b) Pilaster w/3' ret Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item lbs ft ft-# HL Act Pres (ab water tbl) 280.0 1.33 373.3 HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = 103.4 8.44 873.1 Load @ Stem Above Soil = Total = 383.4 O.T.M. = 1,246.4 Resisting/OverturnIng Ratio = 1.77 Vertical Loads used for Soil Pressure = 1,276.9 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 .....RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 345.0 2.50 862.5 Soil Over HL (bel. water tbl) 2.50 862.5 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 57.5 0.50 28.8 Surcharge Over Toe = Stem Weight(s) = 424.4 1.50 636.6 Earth @ Stem Transitions = Footing Weight = 450.0 1.50 675.0 Key Weight = Vert. Component = Total = 1,276.9 lbs R.M.= 2,202.9 • Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.170 in The above calculation is not valid if the heal soil bearing pressure exceeds that of the toe, hegguse the wall would then fend to rotate into the retained soil. 9%0FEssi` H m r. W a Ql b NO. &3660 * EXP- 03/31/2025 s�q CSV TF OF c4ofa4 Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (06c) Pilaster w/4' ret Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Project Title: Engineer: Project ID: Project Descr: Project File: beazor hornes_cantera_la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Criteria 136.4 #/ft Soil Data 6.94 It I Retained Height = 4.00 ft Allow Soil Bearing = 2,666.6 psf (Strength Level) Wall height above soil = 6.67 ft Equivalent Fluid Pressure Method _ 0.0 ft — Poisson's Ratio = 0.300 Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel — 0,0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 136.4 #/ft ...Height to Top = 6.94 It ...Height to Bottom = 7.94 It Load Type = Seismic (E) Footing Type (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) _ 0.0 ft — Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall _ 0.0 ft — Poisson's Ratio = 0.300 Q OFESS /QN �W49 ��ROiIG �4- �y ti < m rrrr rn NO 63660 D EXP 03/31/2025 y� sr C / v tv Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera—la quinta.ec6 LTCfe i Kw -06016003, BuIU20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (06c) Pilaster w/4' ret ASD eaoFESS /0N %I otJ r Fa c� m STI m W pi m NO 83660 D A * EXP 03/31/2025 iP)�r C IV �� v F OF CA0F� Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Overturning = 1.83 OK Design Method = ASD Sliding = 1.37 Ratio < 1.5! Thickness = 12.00 Global Stability — 2.47 Rebar Size — # 4 Spacing = 16.00 rRebar Total Bearing Load = 1,560 lbs Rebar Placed at = Edge ...resultant ecc. = 9.04 in Design Data - Eccentricity outside middle third fb/FB + fa/Fa = 0.349 Soil Pressure @ Toe = 1,193 psf OK Total Force @ Section p V Soil Pressure @ Heel = 0 psf OK Service Level lbs = 375.5 * Allowable = 2,667 psf £ Strength Level lbs = ^� Soil Pressure Less Than Allowable Moment .... Actual 1 :� ACI Factored @ Toe — 1,670 psf Service Level ft-#= 1,179.2 ,T tY ACI Factored @ Heel = 0 psf Strength Level ft-# _ Footing Shear @ Toe = 9.0 psi OK Moment..... Allowable = 3,371.6 Footing Shear @ Heel = 6.6 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 2.7 Sliding Calcs Strength Level psi = Lateral Sliding Force = 533.0 lbs Shear..... Allowable psi = 51.3 less 100% Passive Force - 104.2 lbs Anet (Masonry) in2 = 139.50 less 100% Friction Force =_ - 624.0 lbs Wall Weight psf = 41.2 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in = 9.00 ....for 1.5 Stability = 71.3 lbs NG Masonry Data - Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = Yes Load Factors-- Modular Ration' 16.11 Building Code Equiv. Solid Thick. in= 11.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = ASD eaoFESS /0N %I otJ r Fa c� m STI m W pi m NO 83660 D A * EXP 03/31/2025 iP)�r C IV �� v F OF CA0F� Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 I C4 : 4(VV-06016003. Bulld:20M;2.14 ORCO BLOCK COMPANY INC (0) EI-ERCALC INC 1983-2022 DESCRIPTION: (06c) Pilaster w/4' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.25 Total Footing Width = 3.25 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe: phiMn = ph"5'lambda`sgrt(fc)'Sm Heel: phiMn = ph'5'lambda'sgrt(fc)`Sm Key: No key defined 0 psf 25 ft-# 801 ft-# 776 ft-# OK ,500 ft-# 6.62 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area Toe Heel Factored Pressure = 1,670 Mu': Upward = 729 Mu': Downward = 187 Mu: Design = 542 OK phiMn = 2,500 2 Actual 1 -Way Shear = 8.99 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacinos Toe: phiMn = ph"5'lambda`sgrt(fc)'Sm Heel: phiMn = ph'5'lambda'sgrt(fc)`Sm Key: No key defined 0 psf 25 ft-# 801 ft-# 776 ft-# OK ,500 ft-# 6.62 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.84 int Min footing T&S reinf Area per foot 0.26 in2 ift Ii ane layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in �RpFE55rdry� �a$R DOGO fic co m {1l M ,'.4 DIM, N6, 83660 E%P OVW2625 k s ar C f V } ,11t+`¢ 11 011100 Cantilevered Retaining Wall LICE - KW -06016003, Build:20,23.2.14 DESCRIPTION: (06c) Pilaster w/4' ret Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item lbs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 437.5 1.67 95.5 9.44 729.2 901.4 Total 7 533.0 O.T.M. = 1,630.6 Resisting/Overturning Ratio = 1.83 Vertical Loads used for Soil Pressure = 1,559.9 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: boozer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1993-2622 .....RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 575.0 2.63 1,509.4 Soil Over HL (bel. water tbl) 2.63 1,509.4 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = 57.5 0.50 28.8 Surcharge Over Toe = Stem Weight(s) = 439.9 1.50 659.9 Earth @ Stem Transitions = Footing Weight = 487.5 1.63 792.2 Key Weight = Vert. Component = Total = 1,559.9 lbs R.M.= 2,990.2 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.181 in I lie above calculation is not valid if the heel sail boring pressure exceeds that of the Joe because the wall would then tend to ratale into the retained soil. QaoFEssroN ¢wo �ERtsu � u m �ytl m ❑ m is ply W 63660 * E%P 03mao25 119r C I V `L ¢CNV E OF CAL�F� Cantilevered ReWining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (06d) Pilaster w/5' ret Code Reference. Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 5.00 ft Wall height above soil = 6.67 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore (Strength Level) for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 126.7 #/ft ...Height to Top = 9.94 ft ...Height to Bottom = 8.94 ft Load Type = Seismic (E) Adjacent Footing Load = (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) 0.00 in Project File: beater homes_cantera_la qulnta.ec6 (C) ENERCALC INC 1983.2022 PROFESS/0 --ieRDU C w a. DIS NO. 83660 k EXP. 03/31/2025 * . S4 CIV l4 TF OF CA41ffl4 iI Wp�l l Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil _ at Back of Wall 0.0 ft Poisson's Ratio 0.300 PROFESS/0 --ieRDU C w a. DIS NO. 83660 k EXP. 03/31/2025 * . S4 CIV l4 TF OF CA41ffl4 Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 DESCRIPTION: (06d) Pilaster w/5' ret Project Title: Engineer: Project ID: Project Descr: Project File: beazer homes_cantera_la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Overturning — 1.87 OK Design Method = ASD ding 1.40 Ratio < 1.5! Thickness = 12.00 Stability = 2.33 Rebar Size = # 4 ;Global Rebar Spacing = 16.00 tal Bearing Load = 1,958 lbs Rebar Placed at = Edge ecc. = 9.34 in Design Data V ...resultant •. Eccentricity outside middle third fb/FB + fa/Fa _ 0.464 p i Soil Pressure @ Toe = 1,343 psf OK Total Force @ Section AM Soil Pressure @ Heel = 0 psf OK Service Level lbs = 526.2 Allowable = 2,667 psf Strength Level lbs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe 1,880 psf Service Level ft-#= 1,566.2 ACI Factored @ Heel 0 psf Strength Level ft-# = Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable = 3,371.6 Footing Shear @ Heel = 8.6 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 3.8 Sliding Calcs Strength Level psi = Lateral Sliding Force = 718.7 lbs Shear..... Allowable psi = 51.3 less 100% Passive Force - 222.8 lbs Anet (Masonry) in2 = 139.50 less 100% Friction Force - 783.0 lbs Wall Weight psf = 38.6 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 9.00 ....for 1.5 Stability = 72.2 lbs NG Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting Yes Load Factors----- Modular Ratio'n' = 16.11 Building Code Equiv. Solid Thick. in= 11.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = ASD Q,pFESS 10N RDU w Imo,_ n1 - NQ. 83660 1r EXP. 03/31/2025 sq C'V,L `V re OF CAL 'I Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File; beater homes_canteraJa quinta.ec6 LICK: KW•06016003. Build 20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALE fT+fC 1993-ZQ7.2 DESCRIPTION: (06d) Pilaster w/5' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.50 Total Footing Width = 3.50 Footing Thickness = 12.00 in Key Width = 12.00 in Key Depth = 5.00 in Key Distance from Toe = 1.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe: phiMn = ph"5'lambda`sgrt(fc)'Sm Heel: phiMn = ph'5'lambda'sgrt(fc)'Sm Key: phiMn = phi"5'lambda'sgrt(fc)'Sm 0 psf 83 ft-# ,305 ft-# ,222 ft-# OK ,500 ft-# 8.62 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area Toe Heel Factored Pressure = 1,880 Mu': Upward = 833 Mu': Downward = 187 1 Mu: Design = 646 OK 1 phiMn = 2,500 2 Actual 1 -Way Shear = 10.71 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Soacinas Toe: phiMn = ph"5'lambda`sgrt(fc)'Sm Heel: phiMn = ph'5'lambda'sgrt(fc)'Sm Key: phiMn = phi"5'lambda'sgrt(fc)'Sm 0 psf 83 ft-# ,305 ft-# ,222 ft-# OK ,500 ft-# 8.62 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 0.91 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one laver of horizontal pars: if two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in taoeessrOhl 4w4 ,ERntl � � � SIA N0. 83660 * EV 63/31/2025 �k s � C I V TF 0r CA0, Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 (.ICO: KW.06016{]03, Bulid:2023.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-202? DESCRIPTION: (06d) Pilaster w/5' ret Summary of Overturning & Resisting (Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance oment M Force Distance Moment Item lbs ft ft-# lbs ft ft-# HL Act Pres (ab water tbl) 630.0 2.00 1,260.0 Soil Over HL (ab. water tbl) 862.5 2.75 2,371.9 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.75 2,371.9 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = 88.7 10.44 925.7 Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 57.5 0.50 28.8 - Surcharge Over Toe = Stem Weight(s) = 450.1 1.50 675.2 Earth @ Stem Transitions = Total 718.7 O.T.M. = 2,185.7 Footing Weight = 525.0 1.75 918.8 Key Weight = 62.5 1.50 93.8 Resisting/OverturnIng Ratio = 1.87 Vert. Component = Vertical Loads used for Soil Pressure = 1,957.6 lbs Total = 1,957.6 lbs R.M.= 4,088.3 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wail due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.207 in The above calculation is riot valid it the heel soli bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. eRofessra wrn N0. 83660 ID * EXP 03/31/2025 sT4r C I V E OF CA0FO #4 VERTICAL DROP-IN BARS @ 16" 0/C AND - EA. CORNER #4 TIES @24' 0/C STEEL POST PER L. S. PLANS #4 DOWELS W/ 24' MIN. EXTENSION INTO CMU. @ l6" 0/C J 33' B" 6 v /8" 0 ORCO EN TR Y GA TE PILASTER FOR 1/0 MPH EXPOSURE C WIND CONDITIONS CAPPER L. S. PLANS VOID AREA DO NOT GROUT 32" SQ. ■ #4 BARS @ 9" 0/C EACH WAY 3" CLR (4) #5 VERTS W/ #3 LOOP TIES @ l0' 0/C 4'-I0' SQ. FOOTING DESIGN CRITERIA PER THE 2012 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE= 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE= 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH, f',,, = 2000 PSI. GENERAL NOTES: 1, CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90, NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACKK, PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 1500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ITIS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. B. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9, BLOCK STEM MAY BE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC BLOCK STEM MAY BE PLACED TO l3" EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL 15 READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DETAIL #71 6E"ER HOME CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. e�LpFESSION 3�RDOG c7 iL ^C 2 fn m oz T N0. 83660 * EXP. 03/3//2025 F OF CA`s 0 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes-cantera_la quinta.ec6 LIC# : KW -06016003, Build: 20.23.2.14 OFICO B DC C COMPANY INC (c) BN&ICALC INC 1983.2022 DESCRIPTION: (07) 32" Pilaster Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 0.33 ft Wall height above soil = 7.50 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore Spread Footing for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 834.2 #/ft ...Height to Top = 5.83 ft ...Height to Bottom = 4.83 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio - 0.300 "QROFESSIOk ti1��aUr; �r Z W q' m W 0 m, W. D M N0. 83660 * EXP 03/31/2025 S 4l C / V F�`p f OF CA10� Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (07) 32" Pilaster Project File. bearer homes-cantera_;a qulnta.ec6 (c) ENERCALC INC 1983.2022 ASD eRoRE551Qk 10 �ERai1 r 01 ; , a7 rtl • m a �b N0. 83660 > * EXP. 03/31/2025 STS C r V rF of CNS- itl¢ Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" - Masonry Overturning = 1.28 Ratio < 1.5! Design Method = ASD Sliding = 1.38 Ratio < 1.5! Thickness = 16.00 Global Stability 5.02 Rebar Size # 4 Rebar Spacing = 16.00 Total Bearing Load = 1,955 lbs Rebar Placed at 28 in V ...resultant ecc. = 22.53 in Design Data - 0 ` Eccentricity outside middle third fb/FB + fa/Fa = 0.288 4 Soil Pressure @ Toe = 2,400 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs = 585.9 4� Allowable = 2.667 psf Strength Level lbs = ` Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe 3,360 psf Service Level ft-#= 3,114.4 ACI Factored @ Heel 0 psf Strength Level ft-# = Footing Shear @ Toe = 19.1 psi OK Moment..... Allowable = 10,778.3 Footing Shear @ Heel = 3.5 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 3.1 Sliding Calcs Strength Level psi = Lateral Sliding Force = 614.9 lbs Shear..... Allowable psi = 52.0 less 100% Passive Force - 64.8 lbs Anet (Masonry) in2 = 187.50 less 100% Friction Force =_ - 782.1 lbs Wall Weight psf = 138.3 Added Force Req'd = 0.0 lbs OK Rebar Depth 'd' in= 28.00 ....for 1.5 Stability = 75.5 lbs NG Masonry Data Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = Yes Load Factors Modular Ratio 'n' - 16.11 Building Code Equiv. Solid Thick. in= 15.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = ASD eRoRE551Qk 10 �ERai1 r 01 ; , a7 rtl • m a �b N0. 83660 > * EXP. 03/31/2025 STS C r V rF of CNS- itl¢ Cantilevered Retaining Wall I_ICN : KW.66016003. Build:26.23.2.14 DESCRIPTION: (07) 32" Pilaster Footing Data Toe Width = 1.75 It Heel Width = 3.08 Total Footing Width = 4.83 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft Pc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: Project File: beazer homes_cantera_la quinta.ec6 ❑RCO BLOCK 001APANY INC (c) ENERCALC INC 198M022 Footing Design Results Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 517 ft-# 517 ft-# OK ,500 ft-# 3.48 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area Toe Heel Factored Pressure = 3,360 Mu': Upward = 3,290 Mu': Downward = 478 Mu: Design = 2,812 NG phiMn = 2,500 2 Actual 1 -Way Shear = 19.12 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & SDacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 517 ft-# 517 ft-# OK ,500 ft-# 3.48 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 1.25 in2 Min footing T&S reinf Area per foot 0.26 in2 At If one laver of horizontal bars: If two lavers of horizontai bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Qgof>ssro �p�9v�E�tf7t! � Fy rn w p m NO. 83660 * EXP 03/31/2025 yt qr C ! V 1 v P OF C-m-1FQ ¢ Cantilevered Retaining Wall LICY : KW06016003, Build:20.23 2.14 DESCRIPTION: (07) 32" Pilaster Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item lbs ft ft-# HL Act Pres (ab water tbl) 31.0 0.44 13.7 HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = 583.9 6.33 3,698.1 Load @ Stem Above Soil = Total 614.9 O.T.M. = 3,711.9 Resisting/Overturning Ratio = 1.28 Vertical Loads used for Soil Pressure = 1,955.2 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Project File: beazer homes cantera__la quinta.ec6 (c) ENERCALC INC 1983-2022 Soil Over HL (ab. water tbl) Soil Over HL (bel, water tbl) Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth Q Stem Transitions = Footing Weight = Key Weight = .....RESISTING..... Force Distance lbs ft 66.4 3.96 3.96 67.1 0.88 1,082.5 2.42 725.0 2.42 Moment ft-# 262.8 262.8 58.7 2,616.0 1,751.8 Vert. Component = 14.3 4.83 69.0 Total = 1,955.2 lbs R.M.= 4,758.4 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.180 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. p�OFE55�ON w4�o d�R�uG � tirn rn m c� NO 83660 D * EXP 03/31/2025 sqr IV %\- F Of LAL'�O Lo1e Footing Embedded in Soil LIC# : KW -06016003, Build: 20.23.2.14 DESCRIPTION: (07) gate post footing Code References Calculations per IBC 2021 1807.3, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Pole Footing Shape Circular Pole Footing Diameter ......... 18.0 in Calculate Min. Depth for Allowable Pressures Lateral Restraint at Ground Surface Allow Passive ................ 250.0 pcf Max Passive ................. 2,500.0 psf Controlling Values Governing Load Combinati®p+0.70E Lateral Load 2.726 k Moment 9.804 k -ft Restraint @ Ground Surface Pressure at Depth Actual 1,168.83 psf Allowable 1,218.75 psf Surface Retraint Force 6,999.54 lbs Minimum Required Depth 4.875 ft Footing Base Area 1.767 ft^2 Maximum Soil Pressure 0.0 ksf Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Point Load Distributed Load Project File: beazer cantera pole calcs.ec6 (c) ENERCALC INC 1983-2022 Soil Surface ■10' • � D,tmret 6' 6 MMoment 42° n=AA7ft -1 Oft=387 ft 6501b D 0 io Surface Latet!ral Restraint N 0 Applied Loads - Load Combination Loads - (k) Moments - (ft -k) Lateral Concentrated Load (k) Lateral Distributed Loads (kl _ Applied Moment (kft) Vertical Load (k) 6.136 +D -0.60W 0.419 0.368 +D+0.450W D : Dead Load 0.5420 k 5.415 k/ft k -ft k Lr: Roof Live k 1.286 k/ft k -ft k L : Live k +D+0.70E k/ft k -ft k S : Snow k 3.300 k/ft k -ft k W: Wind k 0.2670 k/ft k -ft k E : Earthquake k k/ft k -ft k H : Lateral Earth k k/ft k -ft k Load distance above TOP of Load above ground surface around surface 6.0 6.0 Lateral Dead Load was BOTTOM of Load above ground surface applied @6' height Load Combination Results ft MMMen,= (6501b)(10ft/2) = 3.25 kips -ft DLateral Deed Lead = (3.25kips-ft / 6ft) = 0.542 kip ft WWindLoad= 26.7psf (1 Oft) = 0.267 kips/ft ESelwic Lead = (0 .80)(6501b) = O.524 Id ft Required Pressure at Depth Soil Increase Depth - (ft) Actual - (psf) Allow - (psf) Factor 3.38 808.9 843.8 1.000 4.13 1,021.7 1,031.3 1.000 1.63 395.3 406.3 1.000 4.00 958.9 1,000.0 1.000 2.38 547.2 593.8 1.000 3.88 912.3 96 Pe s s / o 1.000 2.25 521.8 4tio JADUCCNfPA00 4.88 1,168.8 �� -18.8 3.38 820.9 co m 84 140 m a o M I. N0. 83660 D * EXP- 03/31/2025 V rF 9F C A01094 Forces @ Ground Surface Load Combination Loads - (k) Moments - (ft -k) D Only 0.542 3.252 +D+0.60W 1.503 6.136 +D -0.60W 0.419 0.368 +D+0.450W 1.263 5.415 +D -0.450W 0.179 1.089 +0.60D+0.60W 1.286 4.835 +0.60D -0.60W 0.636 0.932 +D+0.70E 2.726 9.804 +D -0.70E 1.642 3.300 ft MMMen,= (6501b)(10ft/2) = 3.25 kips -ft DLateral Deed Lead = (3.25kips-ft / 6ft) = 0.542 kip ft WWindLoad= 26.7psf (1 Oft) = 0.267 kips/ft ESelwic Lead = (0 .80)(6501b) = O.524 Id ft Required Pressure at Depth Soil Increase Depth - (ft) Actual - (psf) Allow - (psf) Factor 3.38 808.9 843.8 1.000 4.13 1,021.7 1,031.3 1.000 1.63 395.3 406.3 1.000 4.00 958.9 1,000.0 1.000 2.38 547.2 593.8 1.000 3.88 912.3 96 Pe s s / o 1.000 2.25 521.8 4tio JADUCCNfPA00 4.88 1,168.8 �� -18.8 3.38 820.9 co m 84 140 m a o M I. N0. 83660 D * EXP- 03/31/2025 V rF 9F C A01094 Project Title: Engineer: Project ID: Project Descr: Pole Footing Embedded In Soil Project File: beazer cantera pole calcs.ec6 LIC# : KW.06016003. Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (07) gate post footing +D+0.5250E 2.180 8.166 4.63 1,081.6 1,156.3 1.000 +13-0.5250E 1.096 1.662 2.75 622.7 687.5 1.000 +0.60D+0.70E 2.509 8.503 4.63 1,126.3 1,156.3 1.000 +0.60D -0.70E 1.859 4.601 3.75 927.0 937.5 1.000 QpoFESS/nN S 0 N0, 83660 A EXP 03/31/2025 s 1? C IV l ¢acv E OF cm -,F ORCO ENTRY MONUMENT PILASTER FOR //0 MPH EXPOSURE C WIND CONDI TIONS 1.90TE: DIMENSIONS ARE NOT TO SCALE. 32' (TOP SEGMENT) /—r r PIGN CRITERIA PER THE 2022 CBC: I LLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR HIND/SEISMIC PER SOILS REPORT. QUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. I LLOWABLE LATERAL PASSIVE PRESSURE = 150 PCF PER SOILS REPORT. GROUT STRENGTH = 2000 PSI @ 28 DAYS. !EINFORCING STEEL . GRADE 60 WONRY COMPRESSION STRENGTH, f', = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE HIV. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOC4TED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPEC17ON TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 11. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. ORCO 88/6 CMU (TOP SEGMENT) AND 128/6 CMU (BOTTOM SEGMENT) BLOCK CELLS TO BE SOLID GROUTED ONLY. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. #4 TIES 024' 0/C DETAIL # #4 VERT ® 16" 0/C AND BEAZER HOMES Q//e'� m 7 EA. CORNER GANTERA @a CORAL MOUNTAIN NO. 83660 D * EXP. 03/3//2025 T TRACT No. 31249 LA QUINTA, CALIFORNIA s�4 C 1 V TF OF cm_xF Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LTC# : KW•66016668, Buitd:26.03:2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (08) Entry monument pilaster Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria = 868.6 #/ft Soil Data = 5.28 ft Retained Height = 0.33 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.67 ft Equivalent Fluid Pressure Method at Back of Wall Active Heel Pressure = 35.0 psf/ft Slope Behind Wall :• 0.00 Height of Soil over Toe 4.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 868.6 #/ft ...Height to Top = 5.28 ft ...Height to Bottom = 4.28 ft Load Type = Seismic (E) Footing Type (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazer homes_cantera_la quin1a.ec6 (c) ENutdAw INC 1983.2022 Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Fig CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall _ 0.0 ft - Poisson's Ratio - 0.300 .e%ofESS/pH yERDU fi w� w m N0. 83660 tF EXP. 03/31/2025 V Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LEC# : KW -06018008, Bulld:20.23.2.14 ORCO BLOCK COMPANY INC [c] ENERCALC INC 1983-2022 DESCRIPTION: (08) Entry monument pilaster ASD ISOFESS/OH 4'0 �f9DU �.4` ❑7 Cn m w � rni � nIA NO 83660 * EXP 03/31/2025 nT4 CrV L v T� OF CA11F044 Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" - Masonry Overturning - 1.36 Ratio < 1.51 Design Method = ASD Sliding = 1.38 Ratio < 1.5: Thickness = 16.00 Global Stability = 5.25 Rebar Size = # 4 Rebar Spacing = 16.00 Total Bearing Load = 2,042 lbs Rebar Placed at = 28 in ...resultant ecc. = 20.48 in Design Data Eccentricity outside middle third fb/FB + fa/Fa - 0.269 V , V Soil Pressure @ Toe = 2,156 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level lbs = 609.9 ,In Allowable = 2,667 psf Strength Level lbs = Sail Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 3,018 psf Service Level ft -4 = 2,904.6 0 ACI Factored @ Heel = 0 psf Strength Level ft -# _ Footing Shear @ Toe = 20.0 psi OK Moment..... Allowable = 10,778.3 Footing Shear @ Heel = 3.3 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 3.3 Sliding Calcs Strength Level PSI = Lateral Sliding Force = 639.0 lbs Shear..... Allowable psi = 52.2 less 100% Passive Force 64.8 lbs Anet (Masonry) in2 = 187.50 less 100% Friction Force s - 816.8 lbs Wall Weight psf = 171.5 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in= 28.00 ....for 1.5 Stability = 76.8 lbs NG Masonry Data Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = Yes Load Factors Modular Ratio 'n' = 16.11 Building Code Equiv. Solid Thick. in= 15.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data _ Wind, W 1.000 ft psi = Seismic, E 1.000 Fy psi = ASD ISOFESS/OH 4'0 �f9DU �.4` ❑7 Cn m w � rni � nIA NO 83660 * EXP 03/31/2025 nT4 CrV L v T� OF CA11F044 Cantilevered Retaining Wall I IG# : KW06016003, 6uIId:20.23.2.14 DESCRIPTION: (08) Entry monument pilaster Footing Data Toe Width = 1.67 ft Heel Width = 3.00 Total Footing Width = 4.67 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft fc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 Toe: phiMn = ph'5'lambda'sgrt(fc)`Sm Heel: phiMn = ph'5"lambda`sgrt(fc)'Sm Key: No key defined 0 psf 0 ft-# 477 ft-# 477 ft-# OK ,500 ft-# 3.32 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area Toe Heel Factored Pressure = 3,018 Mu': Upward = 2,955 Mu': Downward = 440 Mu: Design = 2,515 NG phiMn = 2,500 2 Actual 1 -Way Shear = 20.00 Allow 1 -Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Accevtable Sizes & Spacings Toe: phiMn = ph'5'lambda'sgrt(fc)`Sm Heel: phiMn = ph'5"lambda`sgrt(fc)'Sm Key: No key defined 0 psf 0 ft-# 477 ft-# 477 ft-# OK ,500 ft-# 3.32 psi 0.00 psi 00 ft -lbs 00 ft -lbs Min footing T&S reinf Area 1.21 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one la er of horizontal bars: II two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in� #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in �p.OFESSION �SRpiJ F cl NO. 83660 * EXP.. 03/31/2025 * . V,L ¢v OP C41.\Io Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW -06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (08) Entry monument pilaster Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item lbs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 31.0 0.44 608.0 5.78 13.7 3,512.4 Total _ 639.0 O.T.M. = 3,526.1 Resisting/OverturnIng Ratio = 1.36 Vertical Loads used for Soil Pressure = 2,042.0 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Project File: beazer homes _cantera_la quinta.ec6 (c) ENERCALC INC 1983.2022 .....RESISTING..... Force Distance Moment lbs ft ft-# Soil Over HL (ab. water tbl) 63.3 3.83 242.5 Soil Over HL (bel. water tbl) 3.83 242.5 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = 63.9 0,83 53.3 Surcharge Over Toe = Stem Weight(s) = 1,200.5 2.33 2,801.6 Earth Q Stem Transitions = Footing Weight = 700.1 2.33 1,633.6 Key Weight = Vert. Component = 14.3 4.67 66.7 Total = 2,042.0 lbs R.M.= 4,797.5 • Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl Q Top of Wall (approximate only) 0.150 in The above calculalton is not valid if ilia heel still bearing ressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. 4Rof Ess roti, ewa 4ffZDU rn M w ��m x NO. 03660 * EXP. 03/31/2025 yt srgr CIV 1 V ¢� p F Or cA0