Loading...
BWFE2024-0041DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Wall / Fence Permit Number: BWFE2024-0041 Property Address: 80378 SEGOVIA VIEW WAY APN: 766150040 Legal Description Lot 75 MB 411/23 TR 31249 Property Zoning: RL, 75 Valuation: $14,000.00 BUILDING PERMIT PHONE (760) 777-7125 �� WWW.LAQUINTACA.GOV APPLIED DATE: 02/02/2024 eca QISSUED DATE: 02/05/2024 CALIFORNIA Owner: Jessica Nicholas 310 Commerce, Suite 150, Irvine, CA 92602 Applicant: Jessica Nicholas 310 Commerce, Suite 150, Irvine, CA 92602 Contractor: Gavin Percy / 818129 310 Commerce, Suite 150, IRVINE, CA 92602 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 2/5/24 9:09 pm Page 1 of 3 1-31111111]1Z"a4 N IT, lIII I Permit Type: Wall / Fence Permit Number: BWFE2024-0041 Property Address: 80378 SEGOVIA VIEW WAY 24 LF GARDEN WALL W/ SPREAD FOOTING. 91 LF GARDEN WALL W/ TRENCH FOOTING. 81 LF FENCE W/ TRENCH FOOTING. Type Group Sq Ft Value Invoice No. Fee Fee Amount Amount Paid INV -00004222 Block Wall - Each Additional 50 LF Garden Wall Linear 115 Engineering Other (Attach Detail) Total Block Wall LF 115 F000tage $7.85 $7.85 Digital Archiving and Records Management Fee - OTC Other fence Linear 81 Zoning RL General Plan LDR Footage $61.02 $61.02 Technology Enhancement Fee City Limits Within La Quinta Limits Subdivision Name TR 31249 Lot Number 75 Lot Size 1348.47 Centerlines 96869 Legal Description Lot 75 MB 411/23 TR $321.76 Grand Total for Permit $321.76 $321.76 31249 Type Group Sq Ft Value Invoice No. Fee Fee Amount Amount Paid INV -00004222 Block Wall - Each Additional 50 LF $18.31 $18.31 Fence - First 100 LF PC $76.89 $76.89 Credit Card Convenience Fee $7.85 $7.85 Digital Archiving and Records Management Fee - OTC $12.00 $12.00 Block Wall - First 100 LF PC $76.28 $76.28 Block Wall - First 100 LF $61.02 $61.02 Technology Enhancement Fee $8.00 $8.00 Fence - First 100 LF $60.41 $60.41 Building Standards Administration $1.00 $1.00 Total for Invoice INV -00004222 $321.76 $321.76 Grand Total for Permit $321.76 $321.76 Workflow Step / Action Name Action Type Start Date End Date Plan Check v.1 02/05/2024 0:00 02/05/2024 12:16 ......... ......... ......... .................. Building Review (1 Day) v.1 Receive Submittal ......... ......... 02/05/2024 0:00 .................................... 02/05/2024 12:16 Permit Issuance v.1 02/05/2024 12:18 02/05/2024 13:09 ................................................................................................................................................................................................................................................................................................................................... Contractor/ Owner -Builder Information v.1 ................................................................................................................................ Generic Action ................ .......... 02/05/2024 12:18 ................................................................................................................................................................................................................................................................................................................................... Verify & Invoice Fees v.1 Generic Action .............. ........ 02/05/2024 12:18 ......................................................................................... Ready to Issue v.1 Generic Action ................ .......... 02/05/2024 12:18 ....................................................................................................................................................... Verify Fee Payment & Issue Permit v.1 Generic Action ................ .......... 02/05/2024 13:09 ....................................................................................................................................................................._ Print, Attach, and Email Building Permit v.1 Create Report 02/05/2024 13:09 ................ .......... 02/05/2024 13:09 Wall / Fence Inspections v.1 ........ ......... ......... ......... ......... ......... ......... Footing v.1 Inspection .... .... ........ ......... ......... ......... ......... ......... ......... ......... Bond Beam v.1 Inspection Final Inspections v.1 Printed: 2/5/24 9:09 pm Page 2 of 3 Permit Type: Wall / Fence Permit Number: BWFE2024-0041 Property Address: 80378 SEGOVIA VIEW WAY 1-3111111111]1Z"a4 N IT, IkI Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 2/5/24 9:09 pm Page 3 of 3 6' ORCO STANDARD CMU SITE WALL W/ TRENCH FOOTING 91 L.F. 6' ORCO STANDARD CMU SITE WALL W/ SPREAD FOOTING 10 L.F. 4Q-0 4R'V4. BWFE20240041 CI TY OF LA QU N TA BU LEI NGoM9CN REM EVED FCR CCCE CCPRLI M CE ORCO CMU + T. S. Taylor Tuvell oma: 02/05/2024 FENCE W/ TRENCH I FOOTING 125LF 6' ORCO STANFARD AND 81 L.F. 81 LF ORCO CMU + T.S FENCE [ORCO SPECIFICATIONS] - - � PRECISION CONCRETE BLOCK =i SHALL BE COVERED WITH L STUCCO, PAINT, OR TEXTURED -t COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2022 CALIFORNIA BUILDING CODES. GARDEN WALL PER LOT 74 LOT 75 PLAN 3C(R) I I I I � , F�4 - - �3— A 3- SEGOVIA VIEW WAY M TI M BEAZER HOMES MSA CONSULTING, INC. > PLANNING > CIVIL ENGINEERING > LAND SURVEYING 34200 Bob Hope Drive, Rancho Mirage, CA 92270 760.320.9811 msaconsultinglnc.com (@ 6' ORCO STANDARD CMU SITE WALL W/ SPREAD FOOTING 14 L.F. CANTERA * CORAL MOUNTAIN OCTOBER 2022 WALL EXHIBITS LOT AREA 10,001 SF 80-378 SEGOVIA VIEW WAY LA GUINTA, CA 92253 SCALE 1'=20' TRACT 31249, LOT 75, PLAN 3C (R) ORCO CMU SITE WALLS W/ SPREAD FOOTING FOR 110 MPH 3 SEC. GUST Cad EXP C REBAR NOTE: • DO NOT RUN HORIZONTAL REINFORCEMENT THROUGH WALL RETURNS & CONTROL JOINTS. • PROVIDE DOWEL & DROP-IN BAR ACCORDING TO DETAIL AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES. O N ORCO 6616 OR 6816 CMU GROUTED ONLY @ VERT STEEL #4 - DROP-IN BAR @ 16" O/C @ CENTER OF CMU #6 STD JOINT REINFORCEMENT @ 12" O/C FOR 6616 CMU @ 16" O/C FOR 6816 CMU #4 DOWEL @ 16" O/C @ CENTER OF CMU. PROVIDE 24" MIN. LAP. SETBACK: AT LEAST THE SMALLEST OF H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #ZA DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + 1 INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5 REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAV CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. BEAZER HOMES CANTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA k O N ti W ti M ORCO CMU SITE WALLS W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST @a EXP C CAP UNIT ORCO 6616 OR 6816 CMU GROUTED ONLY @ VERT STEEL #4 DROP-IN BAR @ 16" O/C @ CENTER OF CMU NOTE: PROVIDE #4 DOWEL & #4 DROP-IN BAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES #6 STD JOINT REINFORCEMENT @ 12" O/C FOR 6616 CMU @ 16" O/C FOR 6816 CMU NOTE: FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURES, A 1/2 BLOCK MAY LEFT OUT @ SWALE GRADE. PROVIDE #4 DOWEL AND #4 DROP-IN BAR ON EACH SIDE OF THE 1/2 BLOCK DRAIN. #4 DOWEL @ 16" O/C @ CENTER OF CMU. PROVIDE 24" MIN. LAP. ti z v ry 2 1 MAX. • #4 HORZ. CONT. v @ 12" O/C, M SETBACK: 8" AT LEAST THE SMALLEST OF CONTT, H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #1B DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + 3 INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL . GRADE 60 6. MASONRY COMPRESSION STRENGTH, f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE Il/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAYBE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA ORCO 12" SQ. PILASTER FOR 110 MPH 3 SEC. GUST @a EXP C DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @a 28 DAYS. 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. N CAP UNIT ORCO 12612 PILASTER CMU SOLID GROUTED. SEE DIAGRAM BELOW GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90, NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A STACK BOND PATTERN. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAV CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT #4 VERT. FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW DROP-IN BAR WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTINGAP . 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. #4 DOWEL W1 24" MIN. EXTENSION INTO CMU J v M EQUAL • #4 HORZ. @ 9" 0/C EACH WAY .3 -O SQUARE FOOT/NG NOTE: ONLY RUN WALL FOOTING HORIZONTAL REINFORCEMENT THROUGH PILASTER FOOTING, WHEN INTERSECTING. DETAIL #2 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHERE INTERSECTION BLOCK WALLS OCCUR. 12" ORCO 12612 PILASTER CMU z (SOLID GROUTED) F v 2 1 MAX. N SETBACK: AT LEAST THE SMALLEST OF H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT #4 VERTICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO SCALE BEAZER HOMES CANTERA L7a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. ORCO CMU + T. S. FENCE W/ SPREAD FOOTING FOR 110 MPH 3 SEC. GUST @a EXP C DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + 3 INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #3 BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA GENERAL NOTES. ry 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. AT LEAST THE SMALLEST OF Z-2" M NORMAL WEIGHT. �i 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM k O C 150 TYPE II/V. Fc = 2500 PSI m 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A U 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 0 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ti IT IS LOCATED. p m 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH N W VERTICAL CONTINUITY OF THE CELLS UNO. W ti 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID Z GROUTED. #4 HORZ. CONT. @ V-1 I� W 7. TOP BOND BEAM USE TYPES MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. tzz (OR z " PENCIL RODS). 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART Q. CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT W #4 DOWEL @ O/C FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW @CENTER OF CMU WITHOUT SEGREGATION OF THE CONSTITUENTS. U) 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE k W U > 10" CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. > #4 HORZ CONTT, 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL ' O Z @ 24" O/C OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. M O O O 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR jEQUAL EQUAL CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND • INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. • (4) #4 HORZ. CONT. AS SHOWN NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #3 BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA ry SETBACK: AT LEAST THE SMALLEST OF Z-2" M H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #3 BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA W 9, I ORCO CMU f T.S. FENCE W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST @a EXP C DESIGN CRITERIA PER THE 2021 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + 3 INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE 111V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. #4 HORZ CONT. @ 24" O/C • 2 1 MAX. • #4 HORZ. CONT. @ 10" O/C • 3" CLR, SETBACK: 10„ AT LEAST THE SMALLEST OF H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #3B 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. #4 HORZ. CONT. @a TOP BOND BEAM 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID (OR "'PENCIL PENCIL RODS). GROUTED. Z USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART #4 DOWEL @ 32" O/C CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PEA @ CENTER OF CMU. GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. #4 HORZ CONT. @ 24" O/C • 2 1 MAX. • #4 HORZ. CONT. @ 10" O/C • 3" CLR, SETBACK: 10„ AT LEAST THE SMALLEST OF H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #3B 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA ORCO 6' HIGH WALL W/ RETAINING & SPREAD FOOTING FOR 110 MPH WIND 3 SEC. GUST @a EXP C SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRY STEM. CAP UNIT ORCO 6616 CMU GROUTED ONLY @ VERT STEEL DESIGN CRITERIA PER THE 2012 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + 3 INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @a 28 DAYS. 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. #4 HORZ. CONT. @24"OIC— N U M U 7' TO DAYLIGHT 6" LEVEL BACKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D -I I liiil I Iiiil I II �1"CLR. �— D' DOWEL 4"DIA. SDR 35 PERF PIPE W11FT WIDE OF 4" GRAVEL WRAPPED W1 MIRAFI 140N FILTER FABRIC TO WITHIN 1FT OF FG - SLOPE TO DRAIN. O WATERPROOF BACKSIDE OF RETAINING WALL. 2" CLR. • \ • EBAR #4 HORZ. CONT. @ 12" 12" 01C AS SHOWN B' NOTE: DIMENSIONS ARE NOT TO SCALE. 'A 'B' GENERAL NOTES: 'D' DOWEL 'E' BAR 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. 2'-6" N/A #4 DROP-IN BAR @32" O/c NORMAL WEIGHT. #4@32" 0/C l8" PROVIDE 24" LAP INTO 8" CMU. 8" 2, CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS 3'-0" 2'-9" SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS #4@l6" 0/C 45" #4@16" 0/C 21- /"8"J OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM QC 150 TYPE II/V. Fc = 2500 PSI 6" F 4'-0" #6 STD JOINT 4" #4@16" O/C 57" REINFORCEMENT @ 12" OIC 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 8„ 8„ F 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 3'-6" 7" NOTE: PROVIDE #4 DOWEL & 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH #4@8" 0/C 30" #4 DROP-IN BAR AT EACH IT IS LOCATED. 8„ SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. #4 HORZ. CONT. @24"OIC— N U M U 7' TO DAYLIGHT 6" LEVEL BACKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D -I I liiil I Iiiil I II �1"CLR. �— D' DOWEL 4"DIA. SDR 35 PERF PIPE W11FT WIDE OF 4" GRAVEL WRAPPED W1 MIRAFI 140N FILTER FABRIC TO WITHIN 1FT OF FG - SLOPE TO DRAIN. O WATERPROOF BACKSIDE OF RETAINING WALL. 2" CLR. • \ • EBAR #4 HORZ. CONT. @ 12" 12" 01C AS SHOWN B' NOTE: DIMENSIONS ARE NOT TO SCALE. 'A 'B' 'C' 'D' DOWEL 'E' BAR 2'-0" 2'-6" N/A #4@32" 0/C 33" #4@32" 0/C l8" 8" 3'-0" 2'-9" N/A #4@l6" 0/C 45" #4@16" 0/C 21- /"8"J 8--1 6" F 4'-0" 3'-0" 4" #4@16" O/C 57" #4@16" 0/C 24" 8„ 8„ F 5'-0" 3'-6" 7" #4@8" 0/C J69" #4@8" 0/C 30" 8„ 8„ F 7. USE TYPES MORTAR PROPORTIONED USING ASTM C270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-I/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%, 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. DETAIL #4 BEAZER HOMES CANTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA ORCO 6' HIGH WALL W/ RETAINING & HEELBACK FOOTING FOR 110 MPH WIND 3 SEC. GUST @a EXP C SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRY STEM. CAP UNIT DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + 3 INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. LEVEL BACKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D CON T 'B' GENERAL NOTES: 444HORZOI @ 24" O/C @ 2'-9" ORCO 6616 CMU x 3'-0" GROUTED ONLY @ VERT STEEL w gc 3'-3" 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. Z) 3'-6" NORMAL WEIGHT. #4 VERT DROP-IN BAR @ 32" O/C 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS cp l7 @ CENTER OF CMU. PROVIDE 24" MIN. LAP INTO 8" CMU SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS Q O Oti OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM g C 150 TYPE 77/V. Fc = 2500 PSI E FG - SLOPE TO DRAIN. o • #6 STD JOINT 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A e REINFORCEMENT 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. @ 12" O/C 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH 2" CLR. IT IS LOCATED. N 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 3"CLR. i 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. LEVEL BACKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D CON T 'B' 'C'&'D' BARS 444HORZOI @ 24" O/C @ 2'-9" 'C' DOWEL x 3'-0" - @ EDGE OF B"CMU 12" w gc 3'-3" #4@16" 0/C Z) 3'-6" 4"DIA. SDR 35 PERF PIPE W/1 FT WIDE OF cp l7 2" CLR GRAVEL WRAPPED W/ Q O Oti MIRAFI 14ON FILTER g FABRIC TO WITHIN 1 FT OF O v� _ FG - SLOPE TO DRAIN. `O • WATERPROOF BACKSIDE OF RETAINING WALL. O D' BAR n 2" CLR. N • • #4 HORZ. CONT. 3"CLR. i @ 12" O/C 3" CLR. 3" CLR. 'A' 'B' 'C'&'D' BARS 2'-0" 2'-9" #4032" 0/C 3'-0" 3'-0" #4@16" 0/C 4'-0" 3'-3" #4@16" 0/C 5'-0" 3'-6" #4@8" O/C 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20'01C. DETAIL #5 BEAZER HOMES CANTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. ORCO 12" SQ. PILASTER W/RETAINING DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 AND 4 OF THE MASONRY STEM. Lu Or W N CAP UNIT ORCO /26/2 PILASTER CMU (SOLID GROUTED) 3-I/2" CLR. (2) #4 VERT. _ DROP -1N BARS #4 DOWELS W/ 24" MIN. EXTENSION INTO CMU. - J LEVEL BACKFILL COMPACTED TO MIN. 90% RELATIVE COMPACTION PER ASTM 1557-D FOR 1/0 MPH EXPOSURE C WIND GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT T02-112 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. FC = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A STACK BOND PATTERN. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHERE INTERSECTION BLOCK WALLS OCCUR. 12' ORCO 12612 F PILASTER CMU ° (SOLID GROUTEI O 4"DIA. SDR 35 PERF PIPE W/ SFT WIDE OF ?' " GRAVEL WRAPPED W/ MIRAFI 140N FILTER FABRIC TO WITHIN 1FT OF J FG 'SLOPE TO DRAIN. U WATERPROOF BACKSIDE OF RETAINING WALL. 7' TO DAYLIGHT #4 HORZ. 12 9" 0/C EACH WAY 'B' SQUARE FOOT/NG NOTE.• ONLY RUN WALL FOOTING HORIZONTAL REINFORCEMENT THROUGH PILASTER FOOTING, WHEN INTERSECTING. 12" N (2) #4 VERTICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO SCALE DETAIL #6 BEAZER HOMES CANTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. 2'-0" 3'-0" N/A 3'-0" 3'-0" N/A 4'-0" 3'-3" N/A 5'-0" 3'-6" 5- 12" N (2) #4 VERTICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO SCALE DETAIL #6 BEAZER HOMES CANTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. ORCO ENTR Y GA TE PILASTER FOR 1/0 MPH EXPOSURE C WIND CONDITIONS I CAPPER L. S. PLANS I #4 VERT/CAL DROP-IN BARS @ l6" 0/C AND - EA. CORNER #4 TIES @24" 0/C STEEL POST PER L. S. PLANS #4 DOWELS W/ 24" MIN. EXTENSION INTO CMU. @ I6" 0/C J 33" DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ITIS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID INA RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8, GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAYBE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTIC4L IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. LPETAIL #7 BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. 8" VOID AREA 2 DO NOT GROUT I3„ I3" v 32" SO. K #4 BARS v @ 9" 0/C EACH WAY 3" CLR J (4) #5 VERTS W/ #3 LOOP TIES @ l0" 0/C 4'-/0" SO. FOOTING GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ITIS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID INA RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8, GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAYBE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTIC4L IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. LPETAIL #7 BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. L/F% ENTR Y MONUMENT PILASTER FOR //0 MPH EXPOSURE C WIND CONDITION NOTE: DIMENSIONS ARE NOT TO SCALE. 32" (TOP SEGMENT) !GN CRITERIA PER THE 2022 CBC: LLOWABLE SOIL BEARING PRESSURE = 2000 PSF + -'j INCR. FOR /IND/SEISMIC PER SOILS REPORT. 2UIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. LLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. ROUT STRENGTH = 2000 PSI @ 28 DAYS. EINFORCING STEEL : GRADE 60 ASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ITIS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID INA RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. ORCO 88/6 CMU (TOP SEGMENT) AND /28/6 CMU (BOTTOM SEGMENT) BLOCK CELLS TO BE SOLID GROUTED ONLY. ENGINE, #4 TIES @24 " 0/C DETAIL #8 16" OIC AND BEAZER HOMES EA. CORNER CgNTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA rill rIN VOID AREA DO NOT GROUT mi rmTmn !GN CRITERIA PER THE 2022 CBC: LLOWABLE SOIL BEARING PRESSURE = 2000 PSF + -'j INCR. FOR /IND/SEISMIC PER SOILS REPORT. 2UIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. LLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. ROUT STRENGTH = 2000 PSI @ 28 DAYS. EINFORCING STEEL : GRADE 60 ASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ITIS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID INA RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. ORCO 88/6 CMU (TOP SEGMENT) AND /28/6 CMU (BOTTOM SEGMENT) BLOCK CELLS TO BE SOLID GROUTED ONLY. ENGINE, #4 TIES @24 " 0/C DETAIL #8 16" OIC AND BEAZER HOMES EA. CORNER CgNTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA