BSOL2022-0008 PlansROOF ACCESS POINT
•
•
4:12
NOTES & LEGENDS
LOT & ARRAY INFORMATION
ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR
INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR
BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT.
(3') WIDE ACCESS PATH (TILE ROOF) / (4') WIDE ACCESS PATH (FLAT ROOF)
DIMENSIONS OF THE INSET ARE LARGER THAN THE ARRAY AND SHALL BE
CONFIRMED BY THE BUILDER BEFORE THE INSTALLATION.
PLAN
2 - LARREA
SYSTEM SIZE
ELEVATION
SANTA BARBARA
STORY TYPE
ROOF TYPE
S-TILE
ORIENTATION
ROOF PITCH
ARRAY SQ. FT.
MODULE QTY.
4:12
340 SQ. FT.
19
MODULE TYPE
SPR-X21-350-BLK-E-AC
LOCATION
LAYOUT/SCHEME
LOT NUMBER
19
15'-6"
4'-10"
•
—FRONT OF HOUSE
DRNEWAY -
TRANSITION BOX
(N) LOAD CENTER (INSIDE GARAGE)
C
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(E) SERVICE POINT AND
UTILITY METERING
D&E
`ROOF ACCESS POINT
TOE ECTRIC
UTILITY GRID
MOUNTING &
ATTACHMENT
INSET - INVISIMOUNT
PHASE NUMBER
6.65 KW
1-STORY
270°
RIGHT
4
35
MODEL
CONDUCTOR / CONDUIT SCHEDULE
TAG
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
❑A
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
#12
2
WITH EGC
#6
1
TYPE -ER, PER
BRANCH CIRCUIT
CU-NM-B
#10
2
EGC BARE CU
#10
1
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
CU-NM-B
#8
3
EGC BARE CU
#10
1
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
❑D
CU-NM-B
#14
3
EGC BARE CU
#14
1
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
❑E
AWG TWISTED PAIR
#22
3
NMFC
INSTALLED IN WALL
CAVITY
1/2"
BSOL2022-0008
CI TY OF LA QU N TA
BULCINGDVISON
REVI EYED FOR
COCE COPRLI AV CE
J. A N A Y A DIE : 02/ 07/ 2022
TOLL BROTHERS/6.65kW SOLAR ARRAY - (19) 350W SUNPOWER
SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ
7XS MICROINVERTERS + 100A PV LOAD CENTER [380SF]. 2019
CALIFORNIA BUILDING CODES
N
1"
SYSTEMS
0
I—
0
a.
LI
0
oo
o,
0
0
S
(510) 540-0550
Ln
o,
oo
oo
Lu
w
LI
J
U
STONE CREEK
TRACT/PARCEL #: 30834
SO CAL - OC/SAN DIEGO
A
SOLAR INDIVIDUAL PLOT PLAN PACKAGE
011111111111111
B11111111111111
O_
LI
0
111111111111111
COMMUNITY ID
PROJECT NO.
DATE DRAWN
DRAWN BY
DATE CHECKED
CHECKED BY
CO02189
RP-184141
2021-12-21
HA[. JAMES LANDICH
2021-12-21
FOR
SHEET
PVA-1
PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES
CAUTION
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
r - 1
r -+-
i
r -+-t-
i
F —+—+-
L_+_t_i
L _ 1 _ J
DRIVEWAY
19 MODULES/MICRO-INVERTER
SPR-X21-350-BLK-E-AC (240
INSET (S-TILE
PEGASUS
PHOTOVOLTAIC
ARRAY ON ROOF
LOAD CENTER
PHOTOVOLTAIC
AC DISCONNECT
MAIN SERVICE
PANEL
80-411 OLD RANCH TRAIL SOUTH
N
7
CI TY OF LA QU N TA
BULUNGDVISON
REVI EYED FOR
COM CO fPLI AV CE
Bo' J.ANAYA E: 02/07/2022
SIGNAGE NOTES
1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT.
2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITHIN MINIMUM 3/8" LETTER HEIGHT, WHITE ON RED BACKGROUND.
3. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE.
SYSTEMS
01
0
I-
0
0
0
0
U
H-
0
V)
>-
0
0
0
_
01
rn
U
0
0
U
0
(510) 540-0550
STONE CREEK
TRACT/PARCEL #: 30834
L/1
0
W
0
SO CAL - OC/SAN DIEGO
8■■■■■■■■■■■■■■
B11111■■■■■■■■■
LI
0
111111■■■■■■■■■
COMMUNITY ID
PROJECT NO.
DATE DRAWN
DRAWN BY
DATE CHECKED
C002189
RP-184141
2021-12-21
HA[. JAMES LANDICH
2021-12-21
CHECKED BY
FOR
SHEET
PVA-2