9802-036 (DSF) Title 24a <-"i
TITLE 24 REPORT FOR:
PHELPS RESIDENCE - RENOVATION
52-820 EISENHOWER
LA QUINTA, CALIFORNIA
PROJECT DESIGNER:
REPORT PREPARED BY:
JOAN. -D. HACKER
INSU-FORM, INC.
68487 HIGHWAY 111, SUITE 56
CATHEDRAL CITY, CA.92264
(619) 324-0216
-!UH .LnPa T
Job
f ANumNb T
j.,�aAd:({3%10/1998
SU 'V
POND ALL APP-LIC"ABLE COLDES
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for�use with both the
Residential and Nonresidential Building Energy Efficiency Standards.
Table Of Contents for Title 24 Report
-------------------------------------
CoverPage...................:....................................... 1
Tableof Contents ................................................... 2
Form CF -1R Certificate of Compliance: Residential ................... 3
Form MF -1R Mandatory Measures Checklist: Residential ................ 5
HVAC Zone & Space Loads Summary ..................................... 7
Form C -2R Computer Method Summary .................................... 10
Form P -2R Point System Summary ...................................... 16
wj
CERTIFICATE OF COMPLIANCE: Residential (part 1 of 2) CF -1R page 3 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE -.RENOVATION Date: 3/10/1998
Address: 52-820 EISENHOWER
LA QUINTA, CALIFORNIA Building Permit No
Designer:
Checked by / Date
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Floor Construction Type:
BUILDING SHELL INSULATION
Component
-----------------------
R-11 Wall (W.11.2x4.16)
Solid Wood Door
R-38 Roof (R. 38.2xl2. 16)
Slab Perimeter w/R-0.0
Slab Perimeter w/R-0.0
FENESTRATION
Orient. Area U -Val Type
COMPLY 24 version 4.11
15
1950 sqft
Single Fam Det
270 deg (W)
1
Slab on Grade
U -Value Location/Comments
------- ------------------------------------
0.098 REVOVATION
0.387 REVOVATION
0.028 REVOVATION
0.900 REVOVATION
0.720 REVOVATION
Back
(E)
80.0
0.55
Double
Back
(E)
9.0
0.75
Double
Back
(E)
13.0
1.19
Single
Right
(S)
16.0
0.75
Double
Front
(W)
80.0
0.55
Double
Front
(W)
28.0
0.75
Double
Front
(W)
9.0
1.19
Single
THERMAL MASS Area Thick
Type Covering (sf) (in) Location/Description
----------------------------- ----- ----- ------------------------------
Concrete, Heavyweight Exposed 265 3.50 Slab on Grade
Concrete, Heavyweight Covered -.1685 3.50 Slab on Grade
Shading
Devices
Frame
Interior
Exterior
OH
SF
Type
---------------
Std
Drape
---------------
none
--
N
--
N
-----
Wood
Std
Drape
none
N
N
Metal
Std
Drape
none
N
N
Metal
Std
Drape
none
N
N
Metal
Std
Drape
none
N
N
Wood
Std
Drape
none
N
N
Metal
Std
Drape,
none
Y
N
Metal
THERMAL MASS Area Thick
Type Covering (sf) (in) Location/Description
----------------------------- ----- ----- ------------------------------
Concrete, Heavyweight Exposed 265 3.50 Slab on Grade
Concrete, Heavyweight Covered -.1685 3.50 Slab on Grade
CERTIFICATE OF COMPLIANCE: Residential (part 2 of 2) CF -1R page 4 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
------------------------------------- ---- ------ -----------------------
Furnace 0.800 AFUE Ducts in Attic 2.1 SetBck RENOVATION
PackAirCond10.000 SEER Ducts'in Attic 2.1 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R -Val
----------------------- ------------------ ------- --- ------ ----- -----
Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec 'Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
----------------------- ----------- ---- ----- ----- ----- -----
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0
SPECIAL FEATURES/REMARKS
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title 24, Parts 1 & 6 of the Califor-
nia Code of Regulations,.and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single building plan to be built in multiple orientations, any shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
(Per Business & Professions Code)
ENFORCEMENT AGENCY
Name:
Title:
Agency:
Telephone:
DOCUMENTATION AUTHOR
JOAN D. HACKER
INSU-FORM, INC.
68487 HIGHWAY 111, SUITE 56
CATHEDRAL CITY, CA 92264
(619) 324-0216
3 (01 CtV
(s nature) (date)
(signature/stamp) (date)
4,
MANDATORY MEASURES CHECKLIST (part 1 of 2) MF-lR page 5 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. COMPLY 24 User 2655
--------------------------------------------------- -------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. Items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
o Sec. 150(a): Minimum R-19 ceiling insulation. *
Enforcement
o Sec. 150(b): Loose fill insulation manufacturers
labeled R -Value.
o Sec. 150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
o Sec. 150(d): Minimum R-13 raised floor insulation in framed
floors; Minimum R-8 in concrete raised floors. *
o Sec. 150(1): Slab edge insulation - water absorption rate
no greater than 0.3%,water vapor transmission rate no
greater than 2.0 perm/inch.
o Sec. 118: Insulation specified or installed meets California
Energy Commission quality standards. Indicate Type & form.
o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label w/certified U -Value
c. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 150(f): Special infiltration barrier installed to
comply with Sec: 151 meets Commission quality standards.
o Sec. 150(e): Installation of Fireplaces, Decorative Gas
Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST (part 2 of 2) MF -1R page 6 of 16
--------------------------------------=------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. (COMPLY 24 User 2655
---------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 110-13: HVAC equipment, water heaters, showerheads
and faucets certified by the Commission.
o Sec. 150(i):. Setback thermostat on all applicable
heating systems.
o Sec..150(j): Pipe and Tank Insulation
1. Indirect hot water tanks (eg unfired storage tanks or
backup solar:hot water tanks) have insulation blanket
(R-12 or greater) or combined interior/exterior insulation
(R-16 or greater).
2. First 5 feet of pipes closest to water heater tank,
non -recirculation systems, insulated (R-4 or greater.
3. All buried or exposed piping insulated in,recirculation
sections of hot water.system.
4. Cooling system piping below 55 F insulated.
5. Piping insulated between heating source and indirect hot
water tank.
o Sec. 150(m) Ducts and Fans *
1. Ducts constructed, installed and sealed to comply with
UMC Sections 1002 and 1004; ducts insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible manually operated
dampers.
o Sec. 114:Pool and Spa Heating Systems and.Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:
a. At least 36" pipe between filter and heater for future
solar heating.
b.`Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
o Sec. 115: Gas-fired central furnace, pool heater, spa heater
or household cooking appliance have no continuously
burning pilot light. (Exception: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
o Sec. 150(k): Lighting - 40 lumens/watt or greater for
general lighting in kitchens and rooms with water closets;
and recessed ceiling fixtures IC (insulation cover) approved.
I I , C
HVAC ZONE HEATING & COOLING LOAD SUMMARY page 7 of 16
---------------------------------------------------------------------------
Project Name: PHELPS.RESIDENCE —RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. COMPLY -24 User 2655
---------------------------------------------------------------------------
HVAC ZONE DESCRIPTION
HVAC Zone Name:
RENOVATION
Heating System Name:
YORK HIRC048
Cooling System Name:
System Multiplier:
1
Fan Schedule:
24 Hr Fans STD
Peak Load Method:
COINCIDENT
Relative Humidity:
50
COOLING
SPACES IN THIS.ZONE PEAK
HEATING
PEAK SENSIBLE
----
LATENT
------
----------------------- ----
REVOVATION (Jan 12am)
-------
33253
--------
(Aug 2pm) 32744
-1664
------
TOTAL SPACE LOAD
-------
33253
--------
32744
-1664
Duct Gains & Losses:
3325
3274
Ventilation: ( 0 CFM)
0
0
0
Return Air Lighting Gain
0
TOTAL SYSTEM LOAD
-------
36578
--------
36018
------
-1664
SYSTEM OUTPUT AT DESIGN CONDITIONS
60000
35028
9282
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
RESIDENTIAL SPACE HEATING LOAD SUMMARY page 8 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. COMPLY 24 User 2655
---------------------------------------------------------------------------
Space Name: REVOVATION
Design Indoor Dry Bulb Temperature:
Design Outdoor Winter Dry Bulb Temperature:
Design Temperature Difference:
70 F
32 F
38 F
Conduction
Area
U -Value
TD
Btu/hr
-----=-----------------
R-11 Wall (W.11.2x4.16)
------
1261.0
x
-------
0.0978
----
x 38.0 =
------
4687
Solid Wood Door
40.0
x
0.3872
x 38.0 =
589
DOUBLE
80.0
x
0.5500
x 38.0 =
1672
DOUBLE
9.0
x
0.7500
x 38.0
= 257
Single Clear Default(R)
13.0
x
1.1900
x 38.0
= 588
DOUBLE
16.0
x
0.7500
x 38.0
= 456
DOUBLE
80.0
x
0.5500
x 38.0
= 1672
DOUBLE
.28.0
x
0.7500
x 38.0
= 798
Single Clear Default(R)
9.0
x
1.1900
x 38.0
= 407
R-38 Roof(R.38.2x12.16)
1950.0
x
0.0282
x 38.0
= 2093
Slab on Grade
Perim =
65.0
x
42
= 2698
Slab on Grade
Perim =
164.0
x
42
= 6806
Infiltration: 1.00 x 0.0181x
1950 sf
x 8.0
ft
x 1.00 AC
x 38.0
= 10592
TOTAL
HOURLY HEAT
LOSS FOR
SPACE
33314
Heating AirFlow: 3331,4
Btu/hr /
(1.07 x
35
F DeltaT)]
= 888
cfm
",
RESIDENTIAL SPACE COOLING LOAD SUMMARY page 9 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
Space Name: REVOVATION
Design Indoor Dry Bulb Temperature:
Design Outdoor Summer Dry Bulb Temperature:
Design Temperature Difference:
78 F
115 F
37 F
Conduction
Op Frac.
--------
Area
------
Area
Conv.
-----
U -Value
DETD
Btu/hr
-----------------------
R-11 Wall (W.11.2x4.16)
x 0.000 x
3.413
------
1261.0
x
-------
0.0978 x
----
30.6 =
------
3774
Solid Wood Door
= 1318
Infiltration: 1.00
40.0
x
0.3872 x
30.6 =
474
DOUBLE
TOTAL HOURLY
LATENT
80.0
x
0.5500 x
37.0 =
1628
DOUBLE
23 F DeltaT)]
= 1497
9.0
x
0.7500 x
37.0 =
250
Single Clear Default(R)
13.0
x
1.1900 x
37.0 =
572
DOUBLE
16.0
x
0.7500 x
37.0 =
444
DOUBLE
80.0
x
0.5500 x
37.0 =
1628
DOUBLE
28.0
x
0..7500 x
37.0 =
777
Single Clear Default(R)
9.0
x
1.1900 x
37.0 =
396
R-38 Roof(R.38.2xl2.16)
1950.0
x
0.0282 x
51.0 =
2809
Infiltration: 1.00.x 0.018 x
1950
sf x 8.0 ft
x 1.00 AC x
37.0 =
10313
Shaded
Unshaded
Solar Gain
Orient.
Area SGF
Area SGF
SC
-----------------------
DOUBLE
---------
West
[
---- ---
0.0 x 15
+
---- ---
80.0 x 73]
----
x 0.58
= 3358
Single Clear Default(R)
West
[
2.3 x 15
+
6.8 x 73]
x 0.70
= 370
DOUBLE
West
[
0.0 x 15
+
12.0 x 73]
x 0.68
= 597
DOUBLE
West
[
0.0 x 15
+
16.0 x 73]
x 0.68
= 795
DOUBLE
East
[
0.0 x 15
+
80.0 x 73]
x 0.58
= 3358
Single Clear Default(R)
East
[
0.0 x 15
+
9.0 x 73]
x 0.70
= 461
Single Clear Default(R)
East
[
0.0 x 15
+
4.0 x 73]
x 0.70
= 205
DOUBLE
East
[
0.0 x 15
+
9.0 x 73]
x 0.68
= 447
DOUBLE
South
[
0.0 x 15
+
16.0 x 32]
x 0.68
= 349
Internal Gain
Op
Frac.
Area
Heat Gain
Conv.
-----------------------
Lighting
--------
1.00
------
x 1950.0
x
---------
0.200 x
-----
3.413 =
1331
Equipment
1.00
x 1950.0
x
0.100 x
3.413 =
666
Occupants
1.00
x 1950.0
x
225 /
333 =
1318
TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 36902
Latent Gain
Op Frac.
--------
Area
------
Heat Gain
---------
Conv.
-----
Btu/hr
------
-----------------------
Equipment
1.00 x
1950.0
x 0.000 x
3.413
= 0
Occupants
1.00 x
1950.0
x 225 /
333
= 1318
Infiltration: 1.00
x 0.018 x 1950 sf
x 8.0
ft x 1.00 AC
x -9.8
= -2736
TOTAL HOURLY
LATENT
HEAT GAIN FOR
SPACE
-1664
Cooling AirFlow:
36902 Btu/hr /
[1.07 x
23 F DeltaT)]
= 1497
cfm
COMPUTER METHOD SUMMARY C -2R page 10 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. COMPLY 24 User 2655
---------------------------------------------------------------------------
POINT SYSTEM COMPLIANCE SUMMARY
Proposed Design Point Score -17 Points *BUILDING COMPLIES*
Budget Compliance Point -Goal -44 Points
EXISTING HOUSE INFORMATION (From Existing C -2R which follows)
Conditioned Floor Area: 1950 sqft
Existing House Point Score -44 Points
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
COMPLY 24 version 4.11
15
1950 sqft
Single Fam Det
270 deg (W)
1
1
Slab on Grade
15600 cuft
1950 sqft
1950 sqft
BUILDING ZONE INFORMATION
Floor # of Vent
Zone Name Area Volume Units Zone Type TStat Type Hgt Area
----------------------- ----- ------ -------------------------- --- ----
RENOVATION 1950 15600 1.00 Conditioned Setback 2 n/a
OPAQUE SURFACES Act Solar
Type Area U -Val Azm Tilt Gains Form 3 Reference Location/Comments
rZ ug"K 1uI�*11;3Kelilly0ce3z1
Wall
243
0.098
270
90
Yes
R-11
Wall
(W.11.2x4.16)
REVOVATION
Door
40
0.387
270
90
Yes
Solid Wood
Door
REVOVATION
Wall
384
0.098
0
90
Yes
R-11
Wall
(W.11.2x4.16)
REVOVATION
Wall
466
0.098
90
90
Yes
R-11
Wall
(W.11.2x4.16)
REVOVATION
Wall
168
0.098
180
90
Yes
R-11
Wall
(W.11.2x4.16)
REVOVATION
Roof
1950
0.028
270
22
Yes
R-38
Roof(R.38.2x12.16)
REVOVATION
COMPUTER METHOD SUMMARY C -2R page 11 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
PERIMETER LOSSES F2 Insulation
Type Length Factor R -Val Depth Location/Comments
--------- ------ ------ ----- ----- -----------------------
ZONE NAME = RENOVATION
Exposed 65.0 0.90 0.0 0 in REVOVATION
Covered 164.0 0.72 0.0 0 in REVOVATION
FENESTRATION SURFACES SC
Act Glass
# Type Area Frame Div U -Val Azm Tilt Only Location/Comments
--------------- ----- ----- --- ----- --- ---- ----- ---------------------
ZONE NAME = RENOVATION
1 Wdw Front (W) 80.0 Wood No 0.55 270 90 0.88 REVOVATION
2 Wdw Front (W) 9.0 Metal No 1.19 270 90 1.00 REVOVATION
3 Wdw Front (W) 12.0 Metal No 0.75 270 90 0.88 REVOVATION
4 Wdw Front (W) 16.0 Metal No 0.75 270 90 0.88 REVOVATION
5 Wdw Back (E) 80.0 Wood No 0.55 90 90 0.88 REVOVATION
6 Wdw Back (E) 9.0 Metal No 1.19 90 90 1.00 REVOVATION
7 Wdw Back (E) 4.0 Metal No 1.19 90 90 1.00 REVOVATION
8 Wdw Back (E) 9.0 Metal No 0.75 90 90 0.88 REVOVATION
9 Wdw Right (S) 16.0 Metal No 0.75 180 90 0.88 REVOVATION
INTERIOR & EXTERIOR SHADING
#
Type
Interior Shade Type
SC
Exterior Shade Type
SC
--
1
----
Wdw
-----------------------
Std
Drape
----
0.78
-----------------------
None
----
1.00
2
Wdw
Std
Drape
0.78
None
1.00
3
Wdw
Std
Drape
0.78
None
1.00
4
Wdw
Std
Drape
0.78
None
1.00
5
Wdw
Std
Drape
0.78
None
1.00
6
Wdw
Std
Drape
0.78
None
1.00
7
Wdw
Std
Drape
0.78
None
1.00
8
Wdw
Std
Drape
0.78
None
1.00
9
Wdw
Std
Drape
0.7.8
None
1.00
COMPUTER METHOD SUMMARY C -2R page 12 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION JDate: 3/10/1998
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
OVERHANGS/SIDE FINS
--Window--
# Type Ht Wd
-- ---- ---- ----
2 Wdw 6.0 1.6
-----Overhang------
Len Ht LExt RExt
---- ---- ---- ----
2.0 0.1 2.0 2.0
---Left Fin--- ---Right Fin --
Dist Len Ht Dist Len Ht
---- ---- ---- ---- ---- ----
THERMAL MASS Area Thick Heat Inside Location
Type (sf) (in) Cap Cond Form 3 Reference R -Val. Comments
------------- ---- ----- ----- --------------------------- ------ --------
ZONE NAME = RENOVATION
Exposed Slab 265 3.50 28 0.98 n/a 0
Covered Slab 1685 3.50 28 0.98 n/a 2
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
------------------------------------- ---- ------ -----------------------
Furnace 0.800 AFUE Ducts in -Attic 2.1 SetBck RENOVATION
PackAirCond10.000 SEER Ducts in Attic 2.1 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R -Val
----------------------- ------------------ ------- --- ------ ----- -----
Std Gas 50.gal or Less Standard StorGas 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
----------------------- ----------- ---- ----- ----- ----- -----
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0
SPECIAL FEATURES/REMARKS
COMPUTER METHOD SUMMARY C -2R page 13 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - EXISTING HOUSE JDate: 3/10/1998
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
POINT SYSTEM COMPLIANCE SUMMARY
Proposed Design Point Score
Budget Compliance Point Goal
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
.Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
BUILDING ZONE INFORMATION
Floor
Zone Name Area
----------------------- -----
EXISTING HOUSE 1950
OPAQUE SURFACES Act Solar
-44 Points *BUILDING DOES NOT COMPLY*
0 Points
COMPLY 24 version 4.11
15
1950 sqft
Single Fam Det
270 deg (W)''
1
1
Slab on Grade
15600 cuft
1950 sqft
1950 sqft
# of Vent
Volume Units Zone Type TStat Type Hgt Area
------ -------------------------- --- ----
15600 1.00 Conditioned Setback 2 n/a
Type Area U -Val Azm Tilt Gains Form 3 Reference Location/Comments
ZONE NAME = EXISTING HOUSE
Wall
273
0.098
270
90
Yes
R-11
Wall
(W.11.2x4.16)
EXISTING
HOUSE
Door
20
0.387
270
90
Yes
Solid Wood
Door
EXISTING
HOUSE
Wall•
384
0.098
0
90
Yes
R-11
Wall
(W.11.2x4.16)
EXISTING
HOUSE
Wall
475
0.098
90
90
-Yes
R-11
Wall
(W.11.2x4'.16)
EXISTING
HOUSE
Wall
184
0.098
180
90
Yes
R-11
Wall
(W.11.2x4.16)
EXISTING
HOUSE
Roof
1950
0.051
270
22
Yes
R-19
Roof
(R.19.2x8.16)
EXISTING
HOUSE
COMPUTER METHOD SUMMARY C -2R page 14 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - EXISTING HOUSE Date: 3/10/1998
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
PERIMETER LOSSES F2 Insulation
Type Length Factor R -Val Depth Location/Comments
--------- ------ ------ ----- ----- -----------------------
ZONE NAME = EXISTING HOUSE
Exposed 65.0 0.90 0.0 0 in EXISTING HOUSE
Covered 164.0 0.72 0.0 0 in EXISTING HOUSE
FENESTRATION SURFACES SC
Act Glass
# Type Area Frame Div U -Val Azm Tilt Only Location/Comments
--------------- ----- ----- --- ----- --- ---- ----- ---------------------
ZONE NAME = EXISTING HOUSE
1 Wdw Front (W) 18.0 Metal No 1.19 270 90 1.00 EXISTING HOUSE
2 Wdw Front (W) 80.0 Metal No 1.19 270 90 1.00 EXISTING HOUSE
3 Wdw Front (W) 9.0 Metal No 1.19 270 90 1.00 EXISTING HOUSE
4 Wdw Back (E) 80.0 Metal No 1.19 90 90 1.00 EXISTING HOUSE
5 Wdw Back (E) 9.0 Metal No 1.19 90 90 1.00 EXISTING HOUSE
6 Wdw Back (E) 4.0 Metal No 1.19 90 90 1.00 EXISTING HOUSE
INTERIOR & EXTERIOR'SHADING
#
Type
Interior Shade Type
SC
Exterior Shade Type
SC
--
1
----
Wdw -
-----------------------
None
----
1.00
-----------------------
None
----
1.00
2
Wdw
None
1.00
None
1.00
3
Wdw
None
1.00
None
1.00
4
Wdw
None
1.00
None
1.00
5
Wdw
None
1.00
None
1.00
6
Wdw
None
1.00
None
1.00
I, Y
COMPUTER METHOD SUMMARY C -2R page 15 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - EXISTING HOUSE Date: 3/10/1998
Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655
---------------------------------------------------------------------------
OVERHANGS/SIDE FINS
--Window-- -----Overhang------ ---Left Fin--- ---Right Fin--
# Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht
-- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
1 Wdw 3.0 6.0 2.0 0.1 2.0 2.0
2 Wdw 6.8 6.0 2.0 0.1 2.0 2.0
3 Wdw 6.0 1.6 2.0 0.1 2.0 2.0
4 Wdw 6.8 6.0 2.0 0.1 2.0 2.0
5 Wdw 3.0 3.0 2.0 0.1 2.0 2.0
6 Wdw 2.0 2.0 2.0 0.1 2.0 2.0
THERMAL MASS Area Thick Heat Inside Location
Type (sf) (in) Cap Cond Form 3 Reference R -Val. Comments
------------- ---- ----- ----- --------------------------- ------ --------
ZONE NAME = EXISTING HOUSE
Exposed Slab 265 3.50 28 0.98 n/a 0
Covered Slab 1685 3.50 28. 0.98 n/a 2
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
------------------------------------- ---- ------ -----------------------
Furnace 0.750 AFUE Ducts in Attic 2.1 SetBck EXISTING HOUSE
PackAirCond 8.000 SEER Ducts in Attic 2.1 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R -Val
----------------------- ------------------ -- ----- --- ------ ----- -----
Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
----------------------- ----------- ---- ----- ----- ----- -----
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0
SPECIAL FEATURES/REMARKS
. C,
POINT SYSTEM SUMMARY P -2R page 16 of 16
---------------------------------------------------------------------------
Project Name: PHELPS RESIDENCE - RENOVATION Date: 3/10/1998
Documentation: INSU-FORM, INC. COMPLY 24 User 2655
--------------------------------------------------- --------------------
BUILDING DATA
Conditioned Floor Area ' 1950 sqft
Occupancy Type Single Fam Det
SCORE CARD Measure.
------------------------- -------
1. Roof Insulation 0.0282
2. Wall Insulation 0.0978
3. Raised Floor Insulation 0.0000
3a. Controlled Vent Crawlspace 0.0
4. Slab Edge Insulation 0.7711
5. Infiltration Standard
6. Glass Heat Loss 0.66
7. Fenestration Heat Gain SC
Orientation Area % Glass Open
------ ------------ ----
North 0.0 0.0 x 0.00 =
East 102.0 5.2 x 0.71 =
South 16.0 0.8 x 0.79 =
West 117.0 6.0 x 0.71 =
Skylight 0.0 0.0 x 0.00 =
8. Interior Thermal Mass 2.18
9. Exterior Wall Mass 0.00
10. Heating System
Zonal Control: No
11. Cooling System
12. Water Heating
Number of Stories 1
Points
(U -Value) 0
(U -Value) -9
(U -Value)
(R -Value) -> 0
(f2 factor)_
C
12.1% 2
Sum 1-6 -7
Ef f %
SER
0.0
0.00 3
3.7
0.85 -4
0.6
0.86 .2
4.3
0.85 -6
0.0
0.00 0
0
0
Sum 7-9
-5
0
-5
=
0
Point
Total:
-17
Point
Goal:
-44
WESTERN INSPECTION SERVICE'
PREFABRICATED TRUSSES
DATE INSPECTED FC-13A),iRy 13,
ADDRESS 110 ,o ; CA PLATE MANUFACTURE
PLANT CONTACT RTIC !A i?
9 t-� e H ENGINEERS DES
NON-SCHEDULED IN -PLANT WOOD TRUSS INSPECTION
AS PER UN1170M BUILDING CODE STANDARDS SE)C.2341 and SEC.2343 and in
ACCORDANCE WITH ENGINEERED PLAN SPECIFICATIONS.
ORDER NO: /OR NAM E J_,L i,,, -r V 11(- -jjt (-4 i.;.1" .I I?
A V# r :;,) 14 J,�? .4,
COMMENTS; r A) C"rt-,A /V, de, pl,e-l) /4A1l) ",)iv &ys-
P/,'A,VT 1llfZ-7.:5 IT'AL,
I'.(
SIGNATURE
P.O. BOX 25251 PoRTLAND,OREGM 97298 503/643-5916 .. -FAX 503/641-7211
CONFORMING
NON CONFORMING
REMARK NO:
LL%SER GRADE
' F
CONNECTOR PLATES
SPAN AND PITCH
QAj -
WORKMANSHIP
JOINT ACCURACY
BEARING OF WOOD JOINTS
lQXM'S IN PLATE AREA
S= LIMITATION
PLATE PLACEMENT
PLATE SIZE
CONDITION OF PLATE TEETH
PLATE TO WOOD TOLERANCE
IN -PLANT HANDLING
V
BUNDLING AND LOADING
ry
STORAGE
MAJ=C LEGIBILITY
c.)
TIG & PRESS ADEQUACY
ORDER NO: /OR NAM E J_,L i,,, -r V 11(- -jjt (-4 i.;.1" .I I?
A V# r :;,) 14 J,�? .4,
COMMENTS; r A) C"rt-,A /V, de, pl,e-l) /4A1l) ",)iv &ys-
P/,'A,VT 1llfZ-7.:5 IT'AL,
I'.(
SIGNATURE
P.O. BOX 25251 PoRTLAND,OREGM 97298 503/643-5916 .. -FAX 503/641-7211