07-3250 (SFD) Title 24I TITLE 24 REPORT I
Title 24 Report for:
Lohman Residence
The Hideaway
La Quinta, CA 92253
Project Designer:
Design Mind Studio
75-175 Merle Drive, Suite 200
Palm Desert, CA 92211
(760) 773-4488
Report Prepared By:
Micah Combs
CM Energy Consulting
P.O. Box 4655
Palm Desert, CA 92261
(760) 449-1308
is i DEC 2 2 21108
Date:
C-1
� U
CIIN OF LA,
B U I L DI N G & S A FE EF V D E-0 I
APPRO 1. V 7 L U
FOR CONSTRUCTION
12/22/2008 1 DATEUJ!PFM- Ply
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.4 by EnergySoft Job Number: User Number: 7403
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
Form WS -SR Residential Kitchen Lighting
2
3
9
11
EnergyPro 4.4 by EnergySoft Job Number. User Number. 7403
Certificate Of Compliance: Residential
5,446 ft2
(Part 1 of 4) CFA R
Lotman Residence
Project Title
Raised Floor Area:
0 ft2
Slab on Grade Area:
12/22/2008
Date
The Hidealwav I a Qilinta
9.8 ft
Number of Dwelling Units:
1.00
Number of Stories:
Project Address
New 09-A6 First Floor
28-A5 First Flnor
N, 01-A18 Serond Flnnr
Building Permit #
QM Fnerav�tina
New- 09-A6 Second Floor
Wall Wood 285 0069 R-21 R-0-0 214 9
(760) 449-1308
DocumentatfiYff Author
Telephone
Plan Check/Date
Fnt-rqVPro
Compliance Method
CA
,lima a Zone 15
Climate Zone
FieldCheck/Date
TDV
Standard
Proposed Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.24
1.93
0.30
Space Cooling
61.20
54.54
6.66
Fans
8.69
10.17
-1.48
Domestic Hot Water
4.44
3.43
1.00
Pumps
0.00
0.00
0.00
Totals
76.56
70.08
6.48
Building Type: Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
Fenestration:
❑ Addition
❑ Existing + Add/Alt
(SW) 225 deg
Natural Gas
Area: 1,634 ft2 Avg. U: 0.34
Ratio: 30.0% Avg. SHGC: 0.30
Total Conditioned Floor Area:
5,446 ft2
Existing Floor Area:
n/a ft2
Raised Floor Area:
0 ft2
Slab on Grade Area:
4,413 ft2
Average Ceiling Height:
9.8 ft
Number of Dwelling Units:
1.00
Number of Stories:
2
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
M,gdn Hnnsp .944 53 427 1 on Cnnditioned Setback /a
OPAQUE SURFACES Insulation Act. Gains Condition
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y /
N Status JA IV Reference Location / Comments
Root_Wnnd 3,380 X25_ R-38 R_no 304
Wall Wood 977 0069 R-21 RR -0.0 304 gQ
Wall Wood 338 0:069 R-21 R-0.0 34 go
Wall Wood 40 0 069 R-21 R_n_0 79 9
Door None 90 0.600 None RR -0.0 79 9
Wall Wood 345 0069 R-21 R-0-0 124 q
Wall Wood 40 0.069 R-21 RR -n n 169 Q
Door None 20 0600 None R-0 (L 169 90
Wall Wood 679 0069 R-21 R0.0 214 90
Wall Wood 40 0.069 R-21 RR -0.0 259 90
Dnor_ None 20 0 80Q Nnne _$_Q-_959 q
Roof Wood 1,033 0 025 R_38 R 0 0 304. o
Wall Wood 440 0.069 _R21 R_0_Q 304 90
Wall Wood 281 0.069 R-21 RR -0.0 34 9
Wall Wood 396 0069 R-21 R-0.0 124 g
®❑['dew
®
®
®
®
®
®
®
®
®
®
®
®
IX
®
®
o❑❑
o
F-1
F-1
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑New
❑
❑New
1:1
❑
❑
°❑
F-1
F-1
El
01-A18 FirstFlnor
New 09-A6 First Floor
New 09-A6 First Floor
(dew 09-A6 First Flnnr
New 28-A5 First Floor
New 09-A6 First Floor
New 09-A6 First Flnnr
New 28-A5 First Flonr
New 09-A6 First Floor
New 09-A6 First Floor
28-A5 First Flnor
N, 01-A18 Serond Flnnr
09-A6 Second Floor
New 09-A6 Second Floor
New- 09-A6 Second Floor
Wall Wood 285 0069 R-21 R-0-0 214 9
New 09-A6 Secnnd Floor
--
Run Initiation Time: 12/22/08 14:41:24 Run Code: 1229985684
EnergyPro 4.4 by Energysoft User Number. 7403 Job Number. Page:3 of 11
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Lohman Residence 12/22/2008
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
Area U -Factor' SHGC2 Azm. Tilt Stat. Glazina TVDe Comments
1-
Window
Left
(NW)
80.0 0.350 NFRC 0.27 NFRC 304 --,qQ New
Sierra Pacific Frnch (I 18A)
First Floor
2
Window
Left
(NW)
32.0
0.350 NFRC 0_27 NFRC
304
90 New
Sierra Pacific Frnch (109A)
First Floor
3
Window
Left
(NW)
42.0
0.350 NFRC 0_27 NFRC
304
90 New
Sierra Pacific Frnch (105B)
First Floor
4
Window
Left
(NW)
42.0
0.350 NFRC 0_27 NFRC
304
90 New
Sierra Pacific Frnch (105A)
First Floor
5
Window
Left
(NW)
42.0
0.350 NFRC 0_27 NFRC
304
90 New
Sierra Pacific Fmch (103B)
First Floor
6
Window
Left
(NW)
4.0
0.320 NFRC 0.38 NFRC
304
90 New
Sierra Pacific Fxd (1-1)
First Floor
7
Window
Left
(NW)
4.0
0.320 NFRC 0.38 NFRC
304c90
New
Sierra Pacific Fxd (1-2)
First Floor
8
Window
Left
(NW)
4.0
0.320 NFRC 0.38 NFRC
304
90 New
Sierra Pacific Fxd (1-3)
First Floor
9
Window
Left
(NW)
4.0
0.320 NFRC 0.38 NFRC
304
_90 New Sierra Pacific Fxd (1-4)
First Floor
_M
Window
Left
(NW)
4.0
0_320 NFRC 0_38 NFRC
304
90 New
Sierra Pacific Fxd (1-5)
First Floor
"
Window
Left
(NW)
26.7
0.320 NFRC 0_38 NFRC
304
90 New
Sierra Pacific Fxd (K1)
First Floor
12
Window
Left
(NW)
6.2
0.320 NFRC 0_38 NFRC
304
90 New
Sierra Pacific Fxd 01)
First Floor
13
Window
Left
(NW)
6.2
0.320 NFRC 0.38 NFRC
304
90 New Sierra Pacific Fxd (J1)
First Floor
14
Window
Rear
(NE)
81.3
0.350 NFRC 0_27 NFRC
34
90 New
Sierra Pacific Frnch (116A)
First Floor
15
Window
Rear
(NE)
76.0
0.350 NFRC 0.27 NFRC
34
90 New
Sierra Pacific Frnch (115C)
First Floor
16
Window
Rear
(NE)
76.0
0.350 NFRC 0_27 NFRC
34
90 New
Sierra Pacific Frnch (115B)
First Floor
17
Window
Rear
(NE)
37.5
0.320 NFRC 0_38 NFRC
34
90 New
Sierra Pacific Fxd (1-11)
First Floor
18
Window
Rear
(NE)
206.5
0.330 NFRC 0.31 NFRC
34
90 New
Sierra Pacific Cmnt (F1)
First Floor
1Q
Window
Rear
(NE)
76.0
0.320 NFRC 0.38 NFRC
34
90 New Sierra Pacific Fxd (F1)
First Floor
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING
Window Overhang Left Fin Right Fin
#
Exterior Shade Type
SHGC Hgt Wd Len Hgt LEA RExt Dist Len Hgt Dist Len Hgt
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick.Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation Condition Location/
R -Val. Location JA IV Reference Status Comments
Slab Perimeter 443 None No Insulation 26-A1 New First Floor
EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number. Page:4 of 11 1
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Lohman Residence 12/22/2008
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazina TVDe Comments
20.
Window
Right
(SE)
40.0 0.350 NFRC 0.27 NFRC 124 _9.Q_ New Sierra Pacific Frnch (115A)
First Floor
21
Window
Right
(SE)
20.0
0.350 NFRC 0.27 NFRC
124
90 New Sierra Pacific Frnch (108A)
First Floor
22
Window
Right
(SE)
81.3
0.360 NFRC 0.32 NFRC
124
90 New Sierra Pacific Sting (106A)
First Floor
23
Window
Right
(SE)
40.0
0.350 NFRC 0_27 NFRC
124
90 New Sierra Pacific Frnch (125A)
First Floor
24
Window
Right
(SE)
32.0
0.350 NFRC 0_27 NFRC
124
90 New Sierra Pacific Frnch (121 A)
First Floor
25
Window
Right
(SE)
12.5
0.320 NFRC 0.38 NFRC
124
90 New - Sierra Pacific Fxd (E1)
First Floor
26
Window
Right
(SE)
20.0
0.320 NFRC 0.38 NFRC
124
90 New Sierra Pacific Fxd (131)
First Floor
27
Window
Right
(SE)
21.2
0.320 NFRC 0.38 NFRC
124
90 New Sierra Pacific Fxd (Cl)
First Floor
28
Window
Front
(SW)
24.0
0.350 NFRQ 0.27 NFRC
214
90 New Sierra Pacific Frnch (110A)
First Floor
22
Window
Front
(SW) 40.0
0.350 NFRC 0.27 NFRC
214
90 New Sierra Pacific Fmch (113A)
First Floor
30
Window
Front
(SW)
42.0
0.350 NFRC 0_27 NFRC
214
90 New Sierra Pacific Frnch (113B)
First Floor
31
Window
Front
(SW)
48.0
0.350 NFRC 0_27 NFRC
214
90 New Sierra Pacific Frnch (132A)
First Floor
,2
Window
Left
(NW)
4.0
0.320 NFRC 0.38 NFRC 304
90 New Sierra Pacific Fxd (01)
Second Floor
33
Window
Left
(NW)
12.0
0.320 NFRC 0_38 NFRC
304
90 New Sierra Pacific Fxd (131)
Second Floor
34
Window
Left
(NW)
4.0
0.320 NFRC 0_38 NFRC
304
90 New Sierra Pacific Fxd (Q3)
Second Floor
35
Window
Left
(NW)
4.0
0.320 NFRC 0.38 NFRC
304
90 New Sierra Pacific Fxd (Q4)
Second Floor
36
Window
Left
(NW)
4.0
0.320 NFRC 0_38 NFRC
304
90 New Sierra Pacific Fxd (Q5)
Second Floor
37
Window
Rear
(NE)
21.3
0.350 NFRC 0_27 NFRC
34
90 New Sierra Pacific Frnch (201A)
Second Floor
-M
Window
Rear
(NE) 20.0
0.350 NFRC 0.27 NFRC 34
90 New Sierra Pacific Frnch (208A)
Second Floor
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING
Window Overhang Left Fin Right Fin
# Exterior Shade Type
SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt.
20 Bug Screen
0.76
21 Bug Screen
0.76
22 Bug Screen
0.76
23 Bug Screen
0.76
24 Bug Screen
0.76
25 Bug Screen
0.76
26 Bug Screen
0.76
27 Bug Screen
0.76
28 Bug Screen
0.76
29 Bug Screen
0.76
30 Bug Screen
0.76
31 Bug Screen
0.76
32 Bug Screen
0.76
33 Bug Screen
0.76
34 Bug Screen
0.76
35 Bug Screen
0.76
36 Bug Screen
0.76
37 Bug Screen
0.76
38 Bug Screen
0.76
THERMAL MASS FOR
HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type
(sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation
R -Val. Location
JA IV Reference
Condition Location/
Status Comments
EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number. Page:5 of 11 1
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Lohman Residence 12/22/2008
Project Title Date
FENESTRATION SURFACES
# Type Area U -Factor' SHGCZ
True
Am. Tilt
Cond.
Stat. Glazing Type
Location/
Comments
-M
Window
Rear
(NE)
88.00
35p NFRC —Q27 NFRC 34 qQ New Sierra Pacific Frnch (205C)
Second Floor
40
Window
Rear
(NE)
4.0
0.320 NFRC 0_38 NFRC
34 90 New
Sierra Pacific Fxd (Q2)
Second Floor
41
Window
Right
(SE)
24.0
0.320 NFRC 0_38 NFRC
124 90 New
Sierra Pacific Fxd (M1)
Second Floor
42
Window
Right
(SE)
24.0
0.320 NFRC 0_38 NFRC
124 90 New
Sierra Pacific Fxd (M2)
Second Floor
43
Window
Right
(SE)
24.0
0.320 NFRC 0_38 NFRC
124 90 New
Sierra Pacific Fxd (M3)
Second Floor
44
Window
Front
(SW)
40.0
0.350 NFRC 0_27 NFRC
214 90 New
Sierra Pacific Frnch (2056)
Second Floor
45
Window
Front
(SW) 20.0
0_350 NFRC 0_27 NFRC
214 9Q New Sierra Pacific Frnch (205A)
Second Floor
46
Window
Front
(SW)
57.0
0.350 NFRC 0.27 NFRC
214 90 New
Sierra Pacific Frnch (201 B)
Second Floor
47
Window
Front
(SW)
12.0
0_320 NFRC 0_38 NFRC
214 9Q New
Sierra Pacific Fxd (132)
Second Floor
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LE t. RExt. Dist. Len. Hgt. Dist. Len. Hgt.
39 Bug Screen 0.76
40 Bug Screen 0.76
41 Bug Screen 0.76
42 Bug Screen 0.76
43 Bug Screen 0.76
44 Bug Screen 0.76
45 Bug Screen 0.76
46 Bug Screen 0.76
47 Bug Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number. Page:6 of 11 1
Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R
Lohman Residence 12/22/2008
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
Main House Central Furnace 92% AFUE Split Air Conditioner 16.2 SEER New Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
Main House Ducted Ducted Attic 4.2 New Yes
Hydronic Piping pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated
Tank
Energy
Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Standby R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE
Loss (%) Ext.
Rheem HE80-199 Large Gas No Pipe Insulation 1 199,000
78
New 0.92
1.17% 0.0
Multi -Family Central Water Heating Details
Hot Water Pump
Control # HP
Hot Water Piping Length (ft) Add 1/2"
In Plenum Outside Buried Insulation
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: Design Mind Studio
Address: 75-175 Merle Drive, Suite 200
Palm DesertCA 92211
eleph ne: 760 7 4 8 Lic. #:
n ture) ` (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature) (date)
Documentation Author
Name: Micah Combs
Title/Firm: CM Energy Consulting
Address: P.O. Box 4655
Palm DesertCA 92261
Telephone: (760),/449-1308
j 4
(signature) (date)
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
Lohman Residence 12/22/2008
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
uaseu un Lae auequacy or me special justmcatnon ano aocumentation suomittea. Plan Field
The DHW System "Rheem HE80-199" is a Large Gas water heater with Pilot Loss = 0 btuh.
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a
1J1vvwa "liIg appwveu reauny anuior venncarlon memoas'
Plan
Field
The HVAC System "Main House" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -
4R.
The Cooling System "MAYTAG PSA413F / PGC1 RC (4 Ton)" includes credit for a 12.5 EER Condenser.
EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:8 of 11 1
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE -
permit application documentation. N/A DESIGNER MENT
Building Envelope Measures
§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
0
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
❑
19
❑
b. outside air intake with damper and control, flue damper and control
❑
❑
❑
2. No continuous burning gas pilot lights allowed.
❑
❑X
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
perrneance rate no greater than 2.0 perm/inch.
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑X
❑
CF -6R Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑X
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
❑X
❑
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑x
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
0
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
N
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
E9
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑X
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑X
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number.
Page:9 of 11
Mandatory Measures Summary: Residential (Page 2 of 2) WAR
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not
applicable.
ENFORCE -
N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,
❑ ❑X ❑
605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of
locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
tape shall be used.
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d).
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials otherthan sealed
❑ ❑X ❑
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support
platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions
in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑ 0 ❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑ ❑X ❑
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑ ❑ ❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ ❑X ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
❑ ❑ ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑X ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
El❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑X ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ IR ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑X ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ❑X ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric
and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ ❑X ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ ❑X ❑
OR are controlled by an occupant sensors) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled
❑ ❑X ❑
by an occupant sensor that complies with Section 119(d) that dries not tum on automatically or have an always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑X ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑X ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680
locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d).
EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number.
Page: 10 of 11
Residential Kitchen Lighting Worksheet WS -5R
Lohman Residence 12/22/2008
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchell Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
(1) 26w Compact Fluorescent Triple 4 Pin Yes X No 37.0 x 7 = 259 or
Yes No I x = or
Yes No L x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x - or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Total A: 259 B: 0
COMPLIES IF A ,-e B YES ® NO ❑
EnergyPro 4.4 by Energysoft User Number: 7403 Job Number. Page: 11 of 11