07-3250 (SFD) Title 24I TITLE 24 REPORT I Title 24 Report for: Lohman Residence The Hideaway La Quinta, CA 92253 Project Designer: Design Mind Studio 75-175 Merle Drive, Suite 200 Palm Desert, CA 92211 (760) 773-4488 Report Prepared By: Micah Combs CM Energy Consulting P.O. Box 4655 Palm Desert, CA 92261 (760) 449-1308 is i DEC 2 2 21108 Date: C-1 � U CIIN OF LA, B U I L DI N G & S A FE EF V D E-0 I APPRO 1. V 7 L U FOR CONSTRUCTION 12/22/2008 1 DATEUJ!PFM- Ply The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 7403 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -SR Residential Kitchen Lighting 2 3 9 11 EnergyPro 4.4 by EnergySoft Job Number. User Number. 7403 Certificate Of Compliance: Residential 5,446 ft2 (Part 1 of 4) CFA R Lotman Residence Project Title Raised Floor Area: 0 ft2 Slab on Grade Area: 12/22/2008 Date The Hidealwav I a Qilinta 9.8 ft Number of Dwelling Units: 1.00 Number of Stories: Project Address New 09-A6 First Floor 28-A5 First Flnor N, 01-A18 Serond Flnnr Building Permit # QM Fnerav�tina New- 09-A6 Second Floor Wall Wood 285 0069 R-21 R-0-0 214 9 (760) 449-1308 DocumentatfiYff Author Telephone Plan Check/Date Fnt-rqVPro Compliance Method CA ,lima a Zone 15 Climate Zone FieldCheck/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.24 1.93 0.30 Space Cooling 61.20 54.54 6.66 Fans 8.69 10.17 -1.48 Domestic Hot Water 4.44 3.43 1.00 Pumps 0.00 0.00 0.00 Totals 76.56 70.08 6.48 Building Type: Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (SW) 225 deg Natural Gas Area: 1,634 ft2 Avg. U: 0.34 Ratio: 30.0% Avg. SHGC: 0.30 Total Conditioned Floor Area: 5,446 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 4,413 ft2 Average Ceiling Height: 9.8 ft Number of Dwelling Units: 1.00 Number of Stories: 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area M,gdn Hnnsp .944 53 427 1 on Cnnditioned Setback /a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Root_Wnnd 3,380 X25_ R-38 R_no 304 Wall Wood 977 0069 R-21 RR -0.0 304 gQ Wall Wood 338 0:069 R-21 R-0.0 34 go Wall Wood 40 0 069 R-21 R_n_0 79 9 Door None 90 0.600 None RR -0.0 79 9 Wall Wood 345 0069 R-21 R-0-0 124 q Wall Wood 40 0.069 R-21 RR -n n 169 Q Door None 20 0600 None R-0 (L 169 90 Wall Wood 679 0069 R-21 R0.0 214 90 Wall Wood 40 0.069 R-21 RR -0.0 259 90 Dnor_ None 20 0 80Q Nnne _$_Q-_959 q Roof Wood 1,033 0 025 R_38 R 0 0 304. o Wall Wood 440 0.069 _R21 R_0_Q 304 90 Wall Wood 281 0.069 R-21 RR -0.0 34 9 Wall Wood 396 0069 R-21 R-0.0 124 g ®❑['dew ® ® ® ® ® ® ® ® ® ® ® ® IX ® ® o❑❑ o F-1 F-1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑New ❑ ❑New 1:1 ❑ ❑ °❑ F-1 F-1 El 01-A18 FirstFlnor New 09-A6 First Floor New 09-A6 First Floor (dew 09-A6 First Flnnr New 28-A5 First Floor New 09-A6 First Floor New 09-A6 First Flnnr New 28-A5 First Flonr New 09-A6 First Floor New 09-A6 First Floor 28-A5 First Flnor N, 01-A18 Serond Flnnr 09-A6 Second Floor New 09-A6 Second Floor New- 09-A6 Second Floor Wall Wood 285 0069 R-21 R-0-0 214 9 New 09-A6 Secnnd Floor -- Run Initiation Time: 12/22/08 14:41:24 Run Code: 1229985684 EnergyPro 4.4 by Energysoft User Number. 7403 Job Number. Page:3 of 11 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Lohman Residence 12/22/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ Area U -Factor' SHGC2 Azm. Tilt Stat. Glazina TVDe Comments 1- Window Left (NW) 80.0 0.350 NFRC 0.27 NFRC 304 --,qQ New Sierra Pacific Frnch (I 18A) First Floor 2 Window Left (NW) 32.0 0.350 NFRC 0_27 NFRC 304 90 New Sierra Pacific Frnch (109A) First Floor 3 Window Left (NW) 42.0 0.350 NFRC 0_27 NFRC 304 90 New Sierra Pacific Frnch (105B) First Floor 4 Window Left (NW) 42.0 0.350 NFRC 0_27 NFRC 304 90 New Sierra Pacific Frnch (105A) First Floor 5 Window Left (NW) 42.0 0.350 NFRC 0_27 NFRC 304 90 New Sierra Pacific Fmch (103B) First Floor 6 Window Left (NW) 4.0 0.320 NFRC 0.38 NFRC 304 90 New Sierra Pacific Fxd (1-1) First Floor 7 Window Left (NW) 4.0 0.320 NFRC 0.38 NFRC 304c90 New Sierra Pacific Fxd (1-2) First Floor 8 Window Left (NW) 4.0 0.320 NFRC 0.38 NFRC 304 90 New Sierra Pacific Fxd (1-3) First Floor 9 Window Left (NW) 4.0 0.320 NFRC 0.38 NFRC 304 _90 New Sierra Pacific Fxd (1-4) First Floor _M Window Left (NW) 4.0 0_320 NFRC 0_38 NFRC 304 90 New Sierra Pacific Fxd (1-5) First Floor " Window Left (NW) 26.7 0.320 NFRC 0_38 NFRC 304 90 New Sierra Pacific Fxd (K1) First Floor 12 Window Left (NW) 6.2 0.320 NFRC 0_38 NFRC 304 90 New Sierra Pacific Fxd 01) First Floor 13 Window Left (NW) 6.2 0.320 NFRC 0.38 NFRC 304 90 New Sierra Pacific Fxd (J1) First Floor 14 Window Rear (NE) 81.3 0.350 NFRC 0_27 NFRC 34 90 New Sierra Pacific Frnch (116A) First Floor 15 Window Rear (NE) 76.0 0.350 NFRC 0.27 NFRC 34 90 New Sierra Pacific Frnch (115C) First Floor 16 Window Rear (NE) 76.0 0.350 NFRC 0_27 NFRC 34 90 New Sierra Pacific Frnch (115B) First Floor 17 Window Rear (NE) 37.5 0.320 NFRC 0_38 NFRC 34 90 New Sierra Pacific Fxd (1-11) First Floor 18 Window Rear (NE) 206.5 0.330 NFRC 0.31 NFRC 34 90 New Sierra Pacific Cmnt (F1) First Floor 1Q Window Rear (NE) 76.0 0.320 NFRC 0.38 NFRC 34 90 New Sierra Pacific Fxd (F1) First Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt Wd Len Hgt LEA RExt Dist Len Hgt Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ R -Val. Location JA IV Reference Status Comments Slab Perimeter 443 None No Insulation 26-A1 New First Floor EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number. Page:4 of 11 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Lohman Residence 12/22/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazina TVDe Comments 20. Window Right (SE) 40.0 0.350 NFRC 0.27 NFRC 124 _9.Q_ New Sierra Pacific Frnch (115A) First Floor 21 Window Right (SE) 20.0 0.350 NFRC 0.27 NFRC 124 90 New Sierra Pacific Frnch (108A) First Floor 22 Window Right (SE) 81.3 0.360 NFRC 0.32 NFRC 124 90 New Sierra Pacific Sting (106A) First Floor 23 Window Right (SE) 40.0 0.350 NFRC 0_27 NFRC 124 90 New Sierra Pacific Frnch (125A) First Floor 24 Window Right (SE) 32.0 0.350 NFRC 0_27 NFRC 124 90 New Sierra Pacific Frnch (121 A) First Floor 25 Window Right (SE) 12.5 0.320 NFRC 0.38 NFRC 124 90 New - Sierra Pacific Fxd (E1) First Floor 26 Window Right (SE) 20.0 0.320 NFRC 0.38 NFRC 124 90 New Sierra Pacific Fxd (131) First Floor 27 Window Right (SE) 21.2 0.320 NFRC 0.38 NFRC 124 90 New Sierra Pacific Fxd (Cl) First Floor 28 Window Front (SW) 24.0 0.350 NFRQ 0.27 NFRC 214 90 New Sierra Pacific Frnch (110A) First Floor 22 Window Front (SW) 40.0 0.350 NFRC 0.27 NFRC 214 90 New Sierra Pacific Fmch (113A) First Floor 30 Window Front (SW) 42.0 0.350 NFRC 0_27 NFRC 214 90 New Sierra Pacific Frnch (113B) First Floor 31 Window Front (SW) 48.0 0.350 NFRC 0_27 NFRC 214 90 New Sierra Pacific Frnch (132A) First Floor ,2 Window Left (NW) 4.0 0.320 NFRC 0.38 NFRC 304 90 New Sierra Pacific Fxd (01) Second Floor 33 Window Left (NW) 12.0 0.320 NFRC 0_38 NFRC 304 90 New Sierra Pacific Fxd (131) Second Floor 34 Window Left (NW) 4.0 0.320 NFRC 0_38 NFRC 304 90 New Sierra Pacific Fxd (Q3) Second Floor 35 Window Left (NW) 4.0 0.320 NFRC 0.38 NFRC 304 90 New Sierra Pacific Fxd (Q4) Second Floor 36 Window Left (NW) 4.0 0.320 NFRC 0_38 NFRC 304 90 New Sierra Pacific Fxd (Q5) Second Floor 37 Window Rear (NE) 21.3 0.350 NFRC 0_27 NFRC 34 90 New Sierra Pacific Frnch (201A) Second Floor -M Window Rear (NE) 20.0 0.350 NFRC 0.27 NFRC 34 90 New Sierra Pacific Frnch (208A) Second Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number. Page:5 of 11 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Lohman Residence 12/22/2008 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Am. Tilt Cond. Stat. Glazing Type Location/ Comments -M Window Rear (NE) 88.00 35p NFRC —Q27 NFRC 34 qQ New Sierra Pacific Frnch (205C) Second Floor 40 Window Rear (NE) 4.0 0.320 NFRC 0_38 NFRC 34 90 New Sierra Pacific Fxd (Q2) Second Floor 41 Window Right (SE) 24.0 0.320 NFRC 0_38 NFRC 124 90 New Sierra Pacific Fxd (M1) Second Floor 42 Window Right (SE) 24.0 0.320 NFRC 0_38 NFRC 124 90 New Sierra Pacific Fxd (M2) Second Floor 43 Window Right (SE) 24.0 0.320 NFRC 0_38 NFRC 124 90 New Sierra Pacific Fxd (M3) Second Floor 44 Window Front (SW) 40.0 0.350 NFRC 0_27 NFRC 214 90 New Sierra Pacific Frnch (2056) Second Floor 45 Window Front (SW) 20.0 0_350 NFRC 0_27 NFRC 214 9Q New Sierra Pacific Frnch (205A) Second Floor 46 Window Front (SW) 57.0 0.350 NFRC 0.27 NFRC 214 90 New Sierra Pacific Frnch (201 B) Second Floor 47 Window Front (SW) 12.0 0_320 NFRC 0_38 NFRC 214 9Q New Sierra Pacific Fxd (132) Second Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LE t. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number. Page:6 of 11 1 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Lohman Residence 12/22/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Main House Central Furnace 92% AFUE Split Air Conditioner 16.2 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Main House Ducted Ducted Attic 4.2 New Yes Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Rheem HE80-199 Large Gas No Pipe Insulation 1 199,000 78 New 0.92 1.17% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Control # HP Hot Water Piping Length (ft) Add 1/2" In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Design Mind Studio Address: 75-175 Merle Drive, Suite 200 Palm DesertCA 92211 eleph ne: 760 7 4 8 Lic. #: n ture) ` (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Micah Combs Title/Firm: CM Energy Consulting Address: P.O. Box 4655 Palm DesertCA 92261 Telephone: (760),/449-1308 j 4 (signature) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Lohman Residence 12/22/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies uaseu un Lae auequacy or me special justmcatnon ano aocumentation suomittea. Plan Field The DHW System "Rheem HE80-199" is a Large Gas water heater with Pilot Loss = 0 btuh. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a 1J1vvwa "liIg appwveu reauny anuior venncarlon memoas' Plan Field The HVAC System "Main House" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The Cooling System "MAYTAG PSA413F / PGC1 RC (4 Ton)" includes credit for a 12.5 EER Condenser. EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:8 of 11 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 0 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ 19 ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ perrneance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑x ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 0 ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ N ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ E9 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number. Page:9 of 11 Mandatory Measures Summary: Residential (Page 2 of 2) WAR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. ENFORCE - N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more tape shall be used. dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials otherthan sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ 0 ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑X ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. El❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑X ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ IR ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑X ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensors) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that dries not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number. 7403 Job Number. Page: 10 of 11 Residential Kitchen Lighting Worksheet WS -5R Lohman Residence 12/22/2008 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchell Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 26w Compact Fluorescent Triple 4 Pin Yes X No 37.0 x 7 = 259 or Yes No I x = or Yes No L x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x - or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 259 B: 0 COMPLIES IF A ,-e B YES ® NO ❑ EnergyPro 4.4 by Energysoft User Number: 7403 Job Number. Page: 11 of 11