Loading...
BPOL2021-0387DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool BPOL2021-0387 54625 AVENIDA CARRANZA 774274017 $30,000.00 Declaration / Acknowledgement BUILDING PERMIT Ottigta CALIFORNIA PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 11/24/2021 ISSUED DATE: 03/15/2022 Owner: ALEXSA GOBEL 2800 TH ST NO 133, SANTA MONICA, CA 92253 Applicant: Mike M McIntyre 83695 AVENUE 45, INDIO, CA 92201 Contractor: Mike M McIntyre / 614611 83695 AVENUE 45, INDIO, CA 92201 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 9/16/24 4:24 pm Page 1 of 3 BUILDING PERMIT Permit Type: Pool Permit Number: BPOL2021-0387 Property Address: 54625 AVENIDA CARRANZA Use of Permit GOBEL / POOL AND SPA AT REAR YARD. *** GOBEL / POOL AND SPA AT REAR YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHI THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. Construction Details Valuation Details Financial Information Invoice No. Fee PERMIT-BPOL2021-038 TECHNOLOGY ENHANCEMENT FEE 7 BSAS SB1473 FEE SWIMMING POOL/SPA/WATER FEATURE PC SWIMMING POOL/SPA/WATER FEATURE RECORDS MANAGEMENT FEE Total for Invoice PERMIT-BPOL2021-0387 Fee Amount $5.00 $2.00 $113.38 $208.41 $11.00 $339.79 Amount Paid $5.00 $2.00 $113.38 $208.41 $11.00 $339.79 Grand Total for Permit $339.79 $339.79 Workflow / Inspections Workflow Step / Action Name Inspections v.1 FINAL** v.3 ......................................................... FINAL** v.2 FINAL** v.1 PRE -PLASTER v.1 DECK BOND v.1 UNDERGROUND PLBG v.1 UNDERGROUND ELEC v.1 PRE-GUNITE v.2 PRE-GUNITE v.1 Action Type Inspection Inspection Inspection Inspection Inspection Inspection Inspection Inspection Inspection Start Date End Date 11/24/2021 0:00 Printed: 9/16/24 4:24 pm Page 2 of 3 BUILDING PERMIT Permit Type: Permit Number: Property Address: Pool B PO L2021-0387 54625 AVENIDA CARRANZA Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 9/16/24 4:24 pm Page 3 of 3 WATER SURFACE PRE -CAST COPING CONC. DECKING 0 w 0 X #35 6"0.C. VERT STL. 3" CLR. I• 339 tp HORIZ. STL. <(\<.‘ 9p THROUGHOUT Fa 16" MIN. LAP „ " IIll llr-IIll j 18" MIN. TRANSI TIO1 8 DEEP END RAMP CONC. DECK �rlt= 1 /Nt 4 MILL VISQUEEN 6" GUNITE W/#3 OR 6" CONC. BLK. W/#3 @ 48"O.C. VERT. STL. SOLID GROUT ALL CELLS 4 #3@ BOND BEAM - 4" #3012"O.C. CLR. rN =UIN= EXPANSIVE (9 6" 33? MAX. 3.1/8" -.■111-1117 RAISED BOND BEAM 0 y 4 #3@ BOND BEAM Sol? MASTIC #3 I x¢ HORIZ.N WALL THK. (MIN.) VERTICAL DEPTH IN FEET NON EXPANSIVE EAPVE 4" 4" 0 FT 4" 4" 1 4" 4" 2FT 4" 4" 3FT 5" 5" 4FT. 6„ 6„ 5FT. 6" 6" 6FT. 6" 8" 7FT. 6" 9" 8FT. #35 6" 0.C. POOL SIDE 4' MIN. W/DECK FTG. 12" 6as ' MIN. W/O DECK FIG. 1/8"TO 1/4" 2" `6 1 L) N� 1/2 OR OR AS REQ'D BY (2I I Y NOTE: THIS SECTION CAN BE USED FOR DEEP END RAMPS UP TO 5' IN DEPTH USE 4 #4 BAR BOND BEAM AND EXTEND BARS 3' EA. SIDE OF RAMP WALL THICKNESS TO CHANGE UNIFORMLY POOL DEPTH 5'0" OR MORE 1 WATER #----`--PLASTER ELECTRICAL PULL BOX 10" ABOVE WATER PER NEC SPECS. 4'-0" 12„ N.T.S. (IILlriLlllt=tl', IIIL-iNL 1=nN= 1riL,1 1/2" I) PVC 10' MIN. LENGTH 4" MIN NLrul=NII-iI1I= T=llll-',l IIIL/NI _ #35 6" 0.C. BOTH WAYS AROUND NICHE D VARIES TO 5" SECTION AT LIGHT BOX FIN. GR. I REINF. GUNITE #35 12" 0.C. BOTH WAYS 4" 0 RECESSED LIGHT D WATER LEVEL MAIN SUMP DRAIN AT LOW POINT DUAL INLETS PER PLUMBING CODE. #3 #3 TH ST 31 @ 12"O.0 g 12"O.0 ROUGHOU P EXTRA T EXTRA #3012"O.0 VERT STEEL AS SHOWN STD. REINFORCEMENT + DIMENSION BOND BEAM STL. 3 #3 FOR NON -EXPANSIVE SOIL 4 #3 FOR EXPANSIVE SOIL WATER SURFACE 1 VERT STL. a HORIZ. STEEL 90? SAML A� ABOVE o M LAP N. w J 0 w z 0 (n w (n POOL DEPTH MASTIC EXPANSIVE JOINT ► 12" /--MASONARY COPING ___/77__________27no04 MORTAR TYPICAL LONGITUDINAL SECTION 7Nr rll=nN-rrll 0 #30 BOND BM. 2" 3"f PLASTER BOND BEAM STANDARD COPING + TILE 0 _ AF,,,_, -Ill -,III IIll ijil I=1IIL= iii1II 2 #3 BARS 4" MIN 1r!i-1111=Illl=llll= 11I1 11ll NEW FILL 4 #3@ BOND BEAM #35 12"O.C. #35 12"O.C. STL. THROUGHOUT VERT STL. NAT. GR. 1111-1111-H1-1111-IN-N NN=Nil= TANNING SHELF DETAIL WATER SURFACE J 12" IIr-IH1= NII- iil�ll ri ELEVATION C 4" PLAN SKIMMER NICHE DETAIL 16" LAP) z ADD #3 12" 0.C. LONGITUDINAL @ TRANSITION WHEN REQ'D BY BLDG. DEPT. 411111-- SCHEDULE - 1 RADIUS SCHEDULE #35 12" 0.C. B.W. 5 IN POOL BOTTOM. CENTER ALL STL. IN GUNITE ems \ n,=nu=k(( 18" MIN. TRANSITION C BEND BOND BM. STL. AROUND NICHE #3 BARS '=IIIFIII- I/II-7/ Ni1=nN_ 4'-0" MAX. 18"" MINh.li TRANS. TYPICAL POOL BOTTOM R=2'6" MAX. R=1'0" MIN. DECK 3 1/2" CONC. SLAB 15 LB. FELT OR 4 MILL VISQUEENNII %N -Nu FINISH GRADE TO WASTE POOL DEPTH „R„ 3'-6" 1'-0" 4'-0" 1'-0" 5'-0" 1'-6" 5'-6" 2'-0" 6'-0" 2'-6" 6'-6" 3'-0" 7'-0" 3'-6" 7'-6" 4'-0" 8'-0" 4'-6" 8'-6" 5'-0" 3" MIN. OR 9AS REQ'D BY CITY Tll loll! 11��Ii IIlI-1111 AP" TRAP DETAIL LEVEL BOND BM. W/ GROUT BEFORE POURING DECK BOND BEAM CANT. CONCRETE DECKING DECK OR CAP MIN. IIII lll=lrrt=ll= ■ uN-uu-Nlr 4" MIN #3 VERT STL. @ 12" 0.C. MASTIC TILE PLASTER 2 #3 BOND BM. #3 HORIZ N 18" 4" MI WATER SURFACE STL.© 12" 0.C. #35 12" 0.C. VERT STL. & �� STRAIGHT WALL SPA z FIN. GR VARIES TO (NEW FILI2 BOND BEAM STL. THROUGHOUT VERT STL. NAT. GR. WATER SURFACE 11W-_ TRANS. H12'd SHALLOW END FILL ADJACENT TO POOL 0 2 #3 BOND BM. VERT STL. STRAIGHT WALL -4111 24" 4" TYP. BOTTOM SECTION W/ SEE TYP. POOL SECTION TYPICAL INFINITE EDGE SECTION WATERTSURFACE POOL IIi1=-Haul 4" TYP. BOTTOM SECTION W/ #35 12" 0.C. B.W. SEE TYP. POOL SECTION SPA ADJACENT TO POOL TYPICAL SPA SECTION MASONARY DECK POOL VENEER WEEP HOLES RAISED PLANTER EXPANSIVE SOIL ONLY 0 PLANTER \__CONC. FT'G MOISTURE BARRIER PROVIDE PLAN (S4 CALCS. FOR RET. WALL. PROJECT: ALTERNATE TO BARRIER PUT IN CONC. BOTTOM (THESE PLANS ARE ONLY VALID FOR THE FOLLOWING SITE) WATER SURFACE 3" TYPICAL POOL BOTTOM POOL DEPTH 5'0" OR LESS POOL DEPTH 5'0" OR MORE POOL NOTES: 1. POOL SHALL BE COMPLETELY ENCLOSED BY APPROVED FENCE. FENCE SHALL BE MIN. 5'-0" HIGH ABOVE THE GROUND. GATES SHALL BE SELF CLOSING AND SELF LATCHING, WITH LATCH 4'-6'' MIN. ABOVE THE GROUND, AS PER LOCAL ORDINANCES. 2. POOL SHALL NOT BE FILLED WITH WATER UNTIL THE FENCE ENCLOSURE HAS BEEN CONSTRUCTED AND APPROVED. 3. PUBLIC POOLS REQUIRE COUNTY HEALTH DEPARTMENT APPROVAL. 4. POOL EQUIPMENT IS NOT PERMITTED IN FRONT YARD OR A REQUIRED SIDE YARD ADJACENT TO MAIN BUILDING. 5. POOL SHALL BE PROVIDED WITH APPROVED FILTER AND DRAIN. 6. ELECTRICAL AND PLUMBING PERMITS TO BE TAKEN OUT AT THE SAME TIME AS POOL BUILDING PERMIT. 7. CEMENT SHALL CONFORM TO CBC/IBC STD. 26-1, A.S.T.M. C 150.62, 175.66. 8. GUNITE SHALL NOT BE LESS THAN 1 TO 4 11/2, 28 DAY 2500 P.S.I. COMP. 9. STEEL SHALL CONFORM TO A.S.T.M. A 615 GR. 40, LAPPED 40 DIA. 10. POOL SHALL BE MIN. 5'-0" FROM BUILDINGS, TREES, OR PROPERTY LINES. 11. SOIL SHALL HAVE BEARING 1000 #1 FT. UNDISTURBED EARTH, NO GROUND WATER. 12. GUNITE TO BE PLACED AGAINST UNDISTURBED EARTH EXCEPT FILL & RAMP. 13. PLUMBING 8c ELECTRICAL INSTALLATION TO CONFORM TO LOCAL CODES. 14. KEEP CONCRETE CONSTANTLY DAMP FOR 14 DAYS. 15. MINIMUM CLEARANCE BETWEEN EARTH AND STEEL TO BE 2". (AREAS OF HIGH SULFATE IN THE SOIL IT SHALL BE 3" MIN. AND BE TYPE 5 CEMENT CONCRETE. 4000 PSI) TYPICAL BOND X BEAM W/4 #3 F"" SEE SCHEDULE .21-1 BOND BEAM STL. CONC. WATER SURFACE4 IDECKING PLACE ADDIT. VERT.STL. IN WALL IN ACCORDANCE WITH SCHEDULE 2. D SEE SCHEDULE 16"MIN BUILDING SURCHARGE EQUIPOTENTIAL BONDING GRID 1. GRID STRUCTURE. THE EQUIPOTENTIAL BONDING GRID SHALL COVER THE CONTOUR OF THE POOL AND THE POOL DECK EXTENDING 3 FT. HORIZONTALLY FROM THE INSIDE OF THE WALLS OF THE POOL. THE EQUIPOTENTIAL BONDING GRID SHALL BE ARRANGED IN 12" X 12" NETWORK OF CONDUCTORS IN A UNIFORMLY SPACED PERPENDICULAR GRID PATTERN WITH TOLERANCE OF 4". 2. SECURING. THE BELOW -GRADE GRID SHALL BE SECURED WITHIN OR UNDER THE POOL AND DECK MEDIA. 3. WHERE THE REINFORCING STEEL IS USED IT SHALL BE BONDED TOGETHER WITH A SOLID COPPER CONDUCTOR NOT SMALLER THAN #6 AWG BARE SOLID COPPER WIRE AT ALL POIINTS OF CROSSING. CONNECTIONS SHALL BE MADE AS REQUIRED BY CEC250.120(C) WHERE ANY REINFORCING STEEL IS EPDXY -TIED TO WALLS #4 REBAR 5/8" DRILL BIT 4 1/4" EMBED 3" EDGE DISTANCE. THE HOLE LOCATIONS, HOLE DIAMETER AND DEPTH, HOLE CLEANING TO BE IN ACCORDANCE WITH SECTION 1704.13 IBC AND THE PRINTED INSTALLATION PER ESR-2508,. THE CARTRIDGE TO BE CHECKED AS TO EXPIRATION DATE. THIS INSPECTION CAN BE BY THE LOCAL BULDING INSPECTOR. AND MAY REQUIRE AN ADDITIONAL INSPECTION FEE. INDIO, AREAS SOUTH OF INDIO AND AREAS IN EXPANSIVE SOIL SEE NOTE NO. 15 DECK EXPANSION JOINTS REQ'D IN DECK AT XPANSIVE SOIL EXPANSIVE SOIL CLR. SCHEDULE 2 ONE STORY HOUSE OR GARAGE FOUND- ATION, 1000 LB./FT. OR FENCE TYPICAL SITE PLAN BOND ALL METALS WITHIN 5' OF WATERS EDGE. ALL PEDESTRIAN GATES TO BE SELF CLOSING AND SELF -LATCHING, DESIGNED TO KEEP DOOR SECURELY CLOSED AT ALL TIMES WHEN NOT IN ACTUAL USE. GATE TO SWING AWAY FROM POOL. ALL SETBACKS TO BE A MIN. OF 5' FROM WATERS EDGE UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. VERIFY ALL SETBACKS WITH THE CITY/COUNTY BEFORE BEGINNING PROJECT. SURCHARGE ADDIT. VERT. STL. BLANK MEANS NO SPECIAL THICKNESS OR REINF. REQUIRED 1/2" Extruded Polystyrene Min. Seperation WATER SURFACE4 t D SEE SCHEDULE 1/2" MIN. APPROVED SEALANT REMAINDER OF JOINT IN CELOTEX OR OTHER EXP. MATERIAL EXPANSIVE JOINT ROCK CONC. fFLOOR 2" CLR. 12" MIN. PRIOR TO FILLING THE SWIMMING POOL WITH WATER, AN APPROVED BARRIER (I.E. UL APPROVED ALARM SYSTEM OR FENCE) MUST BE CHECK CLEARANCE OF SERVICE DROPS WITH ELECTRIC COMPANY GFI AS REQUIRED \_NO OPENINGS MORE THAN 4". NOTE: ALL FENCING TO BE MIN. 5' IN IF POOL EQUIPT. IS LESS THAN 10' FROM ANY WOOD FENCE ON PROPERTY LINE, A 5' MSRY. SOUND WALL MAY BE REQUIRED. ( CHECK WITH BUILDING OFFICIAL) AND ACCESSABLE ONLY BY OWNER OR AGENT. AS OF JAN 1, 2020 THE 2019 EDITIONS OF THE CALIFORNIA BUILDING, FIRE, ELECTRICAL, PLUMBING, MECHANICAL, ENERGY AND EXISTING BUILDING CODES WILL BE EFFECTIVE. REF. SECTION 3109 OF SAID CODE FOR SWIMMING POOL ENCLOSURES AND SAFETY DEVICES. AS OF JAN 1, 2020 THE 2019 EDITION OF THE CALIFORNIA ENERGY CODE WILL BE EFFECTIVE. REF. SECTION 110.4-MANDATORY REQUIREMENTS FOR POOL AND SPA SYSTEMS AND EQUIPMENT. EXAMPLE "COVERS SHALL BE INSTALLED FOR OUTDOOR POOLS WITH HEATERS." ADD FOLLOWING INFORMATION AS APPLICABLE ON SITE PLAN CONE STORY HOUSE OR GARAGE FOUND- ATION, OR ROCK DEEPENED FOOTING IF SIGNATURE IS NOT IN BLUE OR RED INK PLANS ARE INVALID i POOL GENERAL \ SPECIFICATIONS BLANK MEANS NO SPECIAL THICKNESS OR REINF. REQUIRED 1/2" Extruded Polystyrene Min. Seperation WATER SURFACE4 t D SEE SCHEDULE 1/2" MIN. APPROVED SEALANT REMAINDER OF JOINT IN CELOTEX OR OTHER EXP. MATERIAL EXPANSIVE JOINT ROCK CONC. fFLOOR 2" CLR. 12" MIN. PRIOR TO FILLING THE SWIMMING POOL WITH WATER, AN APPROVED BARRIER (I.E. UL APPROVED ALARM SYSTEM OR FENCE) MUST BE CHECK CLEARANCE OF SERVICE DROPS WITH ELECTRIC COMPANY GFI AS REQUIRED \_NO OPENINGS MORE THAN 4". NOTE: ALL FENCING TO BE MIN. 5' IN IF POOL EQUIPT. IS LESS THAN 10' FROM ANY WOOD FENCE ON PROPERTY LINE, A 5' MSRY. SOUND WALL MAY BE REQUIRED. ( CHECK WITH BUILDING OFFICIAL) AND ACCESSABLE ONLY BY OWNER OR AGENT. AS OF JAN 1, 2020 THE 2019 EDITIONS OF THE CALIFORNIA BUILDING, FIRE, ELECTRICAL, PLUMBING, MECHANICAL, ENERGY AND EXISTING BUILDING CODES WILL BE EFFECTIVE. REF. SECTION 3109 OF SAID CODE FOR SWIMMING POOL ENCLOSURES AND SAFETY DEVICES. AS OF JAN 1, 2020 THE 2019 EDITION OF THE CALIFORNIA ENERGY CODE WILL BE EFFECTIVE. REF. SECTION 110.4-MANDATORY REQUIREMENTS FOR POOL AND SPA SYSTEMS AND EQUIPMENT. EXAMPLE "COVERS SHALL BE INSTALLED FOR OUTDOOR POOLS WITH HEATERS." ADD FOLLOWING INFORMATION AS APPLICABLE ON SITE PLAN CONE STORY HOUSE OR GARAGE FOUND- ATION, OR ROCK DEEPENED FOOTING IF SIGNATURE IS NOT IN BLUE OR RED INK PLANS ARE INVALID i POOL GENERAL \ SPECIFICATIONS SIZE X AREA III DEPTH TO SHAPE LINER POOL CAPACITY GALS. PUMP MOTER H.P. FILTER SQ. FT. VACUUM LINE & SKIMMER ,, RETURN LINE MAIN DRAIN 1, SKIMMER MODEL BACKWASH LINE ANTI SIPHON VALVE HEATER SIZE BTU GASLINE BY: VENTED BY: LIGHT CLOCK ELECTRIC BY: ELECTRICAL BONDING BY: POOL CLEANER CHLORINATOR BOARD SUPPORTS WATER SLIDE # COLOR HOOKUP GRADING STUB PLUMB OYES EINO DECK BY: NOTES: POOL NOT TO SCALE DEEP END SHALLOW END SPECIFIED: TO__ DEEP UNLESS OTHERWISE IS__ SHALLOW THIS PLAN AND HEREBY APPROVE POOL AND EQUIPMENT LOCATION C_USTOMERS SIGNATURE DATE SPA GENERAL SPECIFICATIONS SPA TYPE: MDL# DIMENSION: DEPTH: COLOR TOTAL GALLONS SPA JETS TILE HEATER: PUMP 8c MOTOR AIR BLOWER GAS LINE: PLUMBING FOR SPA: ELECTRICAL: CLOCK: EXCAVATION DECKING MISCELLANEOUS: SOLAR GENERAL SPECIFICATIONS SQ. FT POOL SQ. FT. PANEL PANEL TYPE PANEL SIZE NUMBER PANELS PLUMB RUN AUTOMATIC MANUAL THERMOMETERS BOOSTER PUMP SINGLED DOUBLE 0 ELECTRIC BY: OWNER: TO DETERMINE APPROXIMATE ELEVATION OF POOL ON DAY OF EXCAVATION POOL AREA TO BE FENCED, BY OWNER PER COUNTY OR CITY ORDINANCE. GATES TO BE SELF CLOSING AND SELF DO NOT TURN ON POOL LIGHT WHEN POOL IS EMPTY POOL OR SPA NAME ADDRESS CROSS STREETS RES. PHONE BUS. PHONE SWIMMING POOL CONSTRUCTION rJHA Engineers 43585 Monterey Avenue, Suite 7 Palm Desert, CA. 92260 (760) 345-1352 dan jhaengineering.com BPOL2021-0387 CI TY CF LA QU N TA BULONGDVI90N REVI EYED FOR COGS CCIfPLI Al CE BY. J.ANAYA D E: 03/15/2022 0 a 0 0 m z ico w w w a 0 o_ a PROPERTY LINE - - EXISTING BLOCK WALL 5' TYPICAL LAWN U' 0 1 LAWN S. 21' f� 0 0 0 0 0 RAISED PLANTER RAISED PLANTE RAISED BOND BEAM + 12" +12' GREY CONCRETE BROOM FINISH PLANTER OP TANNING LEDGE - 9" DEPTH 0 PLANTER 1I 111?\11111.1 Iw.r.1 1 ■ V K ■ ■LII• ■ ■ ■1a, CONSTRUCTON SPECIALIST BATISTE RESIDENCE 54-625 Ave. Caranza La Quinta, CA 92253 36" SHEER DECENT WATER FEATURE Oo o u POOL 12' x 24' PEBBLE FINISH 16' �Q�� > (0,O GREY•CONCRETE COPING • GREY BROOM FINISH CONCRETE EXISTING PATIO +12' SELF'TCLOSIN SELF -LATHING ATE GOBEL / POOL AND SPA AT REAR YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. 0 0 m z m VM H9O19 ONI1SIX3 1I 111P!\TIT11V41 IVlI'!I MI ■ V K IN I 1%.l I 1 I ■ l\IJ pOLS &S A eii CONSTRUCTION SPECIALIST LICENSE # 614611 McIntyre Pools and Spas, Inc. License #614611 83-695 Avenue 45 Indio, California 92201 760-342-3612 tel. 760-342-3832 fax Project Information: Pool size 12' x 24' Pool area 272 sq. ft. Pool perimeter 72 In. ft. Equipment: Pentair Intelliflo variable speed pump Pentair Clean & Clear 320 filter (3) Pentair GloBrite LED lights 36" Sheer decent water feature Decking: Grey concrete, brushed finish, approx. 270 sq. ft. Batiste Residence 54-625 Avenida Caranza La Quinta, CA 92253 Design by: M. McIntyre Drawn by: M.Noriega Date: 10/29/2021 Pages 1 of 1 Scale: 1/8" = 1 ft.